Tender For Provn Of False Ceiling In Passages Of Building No P-440 And Other Sanctioned Works Of Filteration Plant & Stn Hq At Fazilka Mil Stn.
Tender Value
29.13 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
19 days left
EMD
58500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Fazilka → Punjab
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of False Ceiling In Passages Of Building No P-440 And Other Sanctioned Works Of Filteration Plant & Stn Hq At Fazilka Mil Stn.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m deep for foundation etc and getting out in soft/loose soil. |
| 2 | M&L cement concrete 1:4:8 type D-2 using 40mm graded agg as in foundations filling and in mass concrete. all as specified. |
| 3 | M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified . |
| 4 | M&L Brickwork with Old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 complete all as specified and directed. |
| 5 | Providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate) in lintels upto 1..5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not proivded for, water troughs and the like including weathering, slightly rouinded for chamfered angles and throating, as directing |
| 6 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished flat surfaces of concrete complete all as specified and directed. |
| 7 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc for rough finished surfaces of concrete complete all as specified and directed.. |
| 8 | Form work to soffits of suspended slab such as roof slab, floor slabs landing and similar work; n.exc 200 mm thick |
| 9 | Formwork to edges of concrete flats, breaks in floor, openings in concrete walls, floors and roofs n.exc 20 cm width for rough finished surfaces. |
| 10 | Providing cement concrete type B1 1:2:4 (20 mm graded aggrigate) in lintels upto 1.5 m clear span, cills, steps: seismic and other similer bands, plinth courses, string courses, lacing courses, parapeds and railings upto 60 cm in hights , copings, kneelers, appex stones, bed plates, kerbs not provided for in items 159, water troughs and the like including weathering, slightly rounded for chambered angles and throading , as directing. |
| 11 | M-25 Design mix as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and like using 20 mm graded aggregate |
| 12 | M-25 Design mix as in Beams, cantilevers, bressummers, lintels over 1.5m span (using 20 mm crushed stone graded aggregate) all as specified and shown on drg. |
| 13 | TMT Mild steel bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mmdia or securing with clips |
| 14 | Ditto but 6 mm to 8mm dia |
| 15 | Ditto but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 16 | Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and smooth without using extra cement including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified. |
| 17 | Rendering 15mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement all as specified. |
| 18 | Rendering 5mm thick on brick work or concrete surface in cement mortar 1:3 finished even and smooth without using extra cement all as specified. |
| 19 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft / loose soil. |
| 20 | Removing excavated material n exc. 50m and depositing wheredirected at a level n exc. 1.5 m above the starting point |
| 21 | M&L spreading leveling in layers n exc. 25cm thick and well ramming. |
| 22 | M&L 100mm thick cement concrete 1:3:6 type C-2 in sub base. |
| 23 | M&L broken brick Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface |
| 24 | M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified. |
| 25 | M&L for treating the back fill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface complete all as specified. |
| 26 | M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified. |
| 27 | M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface area complete all as specified. |
| 28 | M&L for treating the soil along with external perimeter of binding at the rate of 2.25 litres of emulsion per running metre complete all as specified. |
| 29 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 30 | Ditto as per item no. 32 above but of frame size 65 x 125 mm. |
| 31 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 32 | Providing and fixing 30 mm thick factory made single extruded WPC (Wood Polymer Composite) solid decorative type skeleton door shutter open rebated and prepared to receive glass, gauze etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, mesh etc.; and comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws all as per direction of Engineer-in- Charge. (Note : Stainless steel butt hinges shall be deemed to be inclusive in unit rate quoted of this item.) |
| 33 | Providing and fixing factory made uPVC white colour Sliding window Three track made of extruded profiles with wall thickness of 2.3mm (+ -0.2mm). Window profile with hollow section with multi chamber. Frame (88mm x 52mm), sliding sash (42mm x 67mm). Sliding mesh Sash (42mm x 57mm) Sliding interlock (One vertical length in each shutters) (45.5mm x 28mm), Glazing bead (24.5mm x 16mm) will be miterd cut and fusion welded at all corners, including drillingof holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware. EPDM gasket, 1.2+ -0.2mm thick galvanised steel Frame (30mm x 18mm) 2 nos, sliding sash (30mm x 18mm), sliding mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasteners, Hardware [Touch Lock of zinc alloyed (white powder coated), steel roller system. Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and required accessories.(Note: The unit rate quoted by contractor excludes cost of glass and includes all other connected accessories. Net Opening will be measured lor payment purpose.)(A) Area not exceeding 2.00 sqm each |
| 34 | S&F 6 mm thick toughened glass as in hinged doors, sliding and fixed windows, glazed partitions, automatic doors and similar works, including cutting to required size and shape, drilling holes, notching, edge polishing and all necessary preparations, complete all as specified and directed. |
| 35 | S&F 300 mm ordinary rat tail rod pattern spring incl roller and roller plate (Brass). |
| 36 | S&F in repair Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc. complete all as specified. |
| 37 | S&F in repair peg set of Six mild steel all as specified |
| 38 | S&F Aluminium anodised barrel tower bolts of extruded section with 150 mm long bolt, all as specified . |
| 39 | S&F Aluminium locking bolts with mild steel electrogalvanised plate and bright bolt not less than 10mm dia, 100mm size |
| 40 | Supply only mild steel cold rolled butt hinges medium weight 100 mm long complete all as specified. |
| 41 | S&F Aluminium handle, cast type, anodised 150 mm long complete all as specified. |
| 42 | M&L for applying two coats of Oil emulsion distemper on walls including preparation of newly plastered surfaces with 3mm thick wall care putty complete all as specified. |
| 43 | M&L for applying three coats of white washing on ceiling including preparation of newly plastered surfaces complete all as specified. |
| 44 | M&L two coats of cement base paint and including preparation of surface new. |
| 45 | M&L for screed bed or bedding layer of mortar 15mm thick in cement mortar 1:4 for laying floor finishes complete all as specified. |
| 46 | M&L for 10mm thick rendering/screeding on fair faces of brick / concrete surfaces in cement mortar 1:4 and finished even and fair for receiving tiles complete all as specified. |
| 47 | M&L Glazed ceramic tiles in vertical surface 350x250mmx7mm/450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and directed. |
| 48 | M&L Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. |
| 49 | M&L Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. |
| 50 | M&L for providing 75 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified. |
| 51 | M&L for levelling course for roof slab, Type B0, 1:2:4 (12.5 mm graded aggregate) using waterproofing compound (SBR) for maintaining proper roof slope and finishing cement concrete surface even and smooth wihout using extra cement complete all as specified. (Minimum thickness of concrete should not be less than 25mm at any point)Note : Waterproofing compound should be measured and paid seperately. |
| 52 | Supply of SBR waterproofing compound @ 2% of per kg cement used complete all as speccified.Make : Fosroc/Sika/Choksey/Chemsol/Bostik/STP |
| 53 | OVERLAY- PU BASED ELASTOMERIC LIQUIED MEMBRANE SYSTEM FOR EXPOSED ROOF : Providing and applying polyurethane liquid roof waterproofing with improved water ponding capability, thermal insulating elastomeric high build liquid membrane for concrete roofs for exterior wall and exposed surface with solid content not less than 80% and solar reflective index 109 as per (ASTM E1980-19)/tear strength ~20 N/mm (Free film, 14 days, +30 degree C) (ASTM D624) and tensile strength 2 N/mm2 (ASTM D4541).(a) After proper surface preparation, Apply one coat of Primer for PU coating as per manufacturers specification.(b) Apply 1st coat of ShaliUrethane® BTD (white) @ 650 gm / m²(minimum) or equivalent by brush / roller while prime surface is tacky, Spread waterproofing reinforced Glass Fiber mash of 45 GSM with overlaps of 50 mm in both directions when the surface is still tacky. Allow 1st coat to dry.(c ) Apply 2nd & 3rd coat of ShaliUrethane® BTD (white) @ 650 gm / m² (minimum) orequivalent by brush/roller.Make : Fosroc/Sika/Choksey/Chemsol/Bostik/STPNote : (i) The Minimum dry film thickness (DFT) of roof treatment shall be 1.5mm if any shortfall in thickness of above treatment the same shall be achieved by additional coat. (ii) The procurement of material and execution of the work of water proofing treatment shall be carried out by authorised applicator approved by GE.(iii) The manufacturer/authorised applicactor shall give a warranty for the performance & durability for 10 years. |
| 54 | S&F in repair wall mounted Viterous China wash down water closet pan pedestral pattern,white including connection pipe to flushing cistern anti syphonage pipe with pvc flush pipe of 32 mm dia and 'P' or 'S' trap device and incl. plastic seat cover and concealed cistern with 05 & 10 Ltr both flushing option with mild steel chromium plated hinging complete all as specified and as directed by engineer-in charge. make cera cat no.S1041101 OR equivalent. |
| 55 | S&F Chromium plated health faucet 1 mtr long fixed with screws complete all as specified and directed. |
| 56 | S&F EWC Jet spray complete all as specified and directed. |
| 57 | S&F in repair 600mmx450mm beveled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers. |
| 58 | S&F vitreous china wash hand basin white flat back of size 550x400 mm with pedestal including bracket, cutting for and pinning the ends of brackets or erecting stands exclusive of waste pipe but including brass chromium plated waste coupling with long screwed sank and fly nuts complete all as specified. |
| 59 | S&F Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/platic cleats (minimumweight 300gms) |
| 60 | S&F towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic screws |
| 61 | Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I of capacity 500 ltr |
| 62 | Supply & fixing 3 layer PPR CONCEALED PIPES of size 16mm SDR 7.4 (PN16) UV stabilised having thermal stability for hot and cold water supply incl. all PPR plain and brass threaded polypropylene random fittins fixed to walls complete all as specified. |
| 63 | Supply & fixing 3 layer PPR CONCEALED PIPES of size 20mm SDR 7.4 (PN16) UV stabilised having thermal stability for hot and cold water supply incl. all PPR plain and brass threaded polypropylene random fittins fixed to walls complete all as specified. |
| 64 | S&F Stop valve, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of 20mm bore and fixed in repairs, all as specified. |
| 65 | S&F Stop valve,fancy type, chromium plated, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions of bore dia 15mm all as specified. |
| 66 | S&F Bib taps fancy type, cast copper alloy, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule and fixed for bore of pipe 15 mm, all as specified. |
| 67 | S&F Pillar taps, fancy type, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, all as specified. |
| 68 | S&F PVC connections 15 mm size with PTMT nuts of length 450 mm. |
| 69 | S&F Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for ironpipe and fixed. (Minimum weight 210 gms) complete screwed for iron pipe or brass ferrule of size 20 mm bore. |
| 70 | Supply & fixing 100mm bore UPVC (SWR) pipes including necessary fittings like band ,tee,coupler,floor trap etc. single socketed (pressure rating not less than 6kg/sqcm) in any length with rubber ring joints for drain or rain water fixed along walls with and including PVC clampps and laid in trenches or in floors complete all as specified and as directed by Engineer-in- charge. |
| 71 | Supply & fixing 75mm bore UPVC (SWR) pipes including necessary fittings like band ,tee,coupler,floor trap etc. single socketed (pressure rating not less than 6kg/sqcm) in any length with rubber ring joints for drain or rain water fixed along walls with and including PVC clamps and laid in trenches or in floors complete all as specified and as directed by Engineer-in- charge. |
| 72 | S&F PVC (SWR) 75mm floor trap, plain with grating including jointing with solvent cement |
| 73 | S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement |
| 74 | M&L for 75mm thick cement concrete type D-2 (1:4:8) using 40mm graded stone aggregate as in sub floors, sub bases etc all as specified and directed by Engineer - in - Charge. |
| 75 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratorymethod using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand; complete. |
| 76 | Framed work for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc in for ornamental and intricate design gates such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 77 | M&L for preparation of steel and iron surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over a coat of Red oxide primer complete all as specified and directed. |
| 78 | Brickwork with sewer bricks straight or curved on plan exc 6 m mean radius for man-holes/ septictank/ soakwell etc. in sewer works in cement mortar 1:4 complete all as specified and directed |
| 79 | Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20 mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, with Chromium plated brass screws & washers fittings and for 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ) |
| 80 | All as per Item No.79 above here in before but for One three pins 5 Amps switch socket outlet point on independent board with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed. (socket shall be measured and paid separately under appropriate item of BOQ) |
| 81 | All as per Item No.79 above here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. (socket shall be measured and paid separately under appropriate item of BOQ) |
| 82 | Description all as per item No.79 above here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.(switch, socket shall be measured and paid separately under appropriate item of BOQ) |
| 83 | S & F modular switch 5/6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 84 | S & F modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 85 | S & F modular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 86 | S & F modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 87 | M&L for Ceiling Rose, surface bakelite 12 to 3 terminal, 240 volts, 5 Amp ISI marked complete all as specified and directed. |
| 88 | S & F of MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 6 to 32 Amps all as specified and directed. |
| 89 | S & F of MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 16 to 40 Amps all as specified and directed. |
| 90 | S&F Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 8 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed.. |
| 91 | S&F sheet metal enclouser TPN DB having facility to fix MCB TPN upto 100 amp and MCB in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill protector,insulated bus bar assembly and blanking plates including making good disturbed surfaces complete all as specified and directed. |
| 92 | Supply and fixing MCB TP 63 Amps 415 Volts complete taking down old unserviceable one and making necessary connections complete all as specified and directed. |
| 93 | Supply and fixing MCB TP 40 Amps 415 Volts complete taking down old unserviceable one and making necessary connections complete all as specified and directed. |
| 94 | Supply and fixing complete set of 1x10 watt LED retrofit type bulkhead fitting luminaries die cast aluminium alloy body heat resistant prismatic glass cover with specially designed gasket lamp holder etc complete with all accessories and including connecting up with twin core twisted flexible copper conductor cable with suitable size light fitting any type complete all as specified and directed by Engineer-in-Charge. |
| 95 | S&F and testing LED light fitting 1x18watt 4 feet long including LED tube with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through h oles. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. |
| 96 | M&L for submain wiring comprising single core ,2 Runs of 10 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits heavy duty and conduit fittings/existing concealed conduit complete, including provision of 1 x 10 sqmm nominal cross sectional area multistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire complete all as specified.( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 97 | Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 26W (± 10%), Temperature rise 40 degree maximum with remote, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account |
| 98 | Supply and fixing Air freshener fan PVC body, AC single Phase 230V, 50 Cycle per second, size 250mm sweep with blades and frame including self closing GI louvers off mode protection against birds etc mounted in suitable opening arrangement and connecting up and including three core PVC Insulated PVC Sheathed copper conductor flexible cable1.0 Sqmm drawn in flexible PVC conduit and hanging on wall with 4 Nos steel fastners 10mm dia 100mm long and making good the disturbed surface complete all as specified and as directed by Engineer-in-charge. |
| 99 | S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm 4 core complete all as specified and as directed by Engineer-in-charge. |
| 100 | Excavation in trenches in any type of soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC/Steel tubular poles/stays and struts etc getting out including trimming sides and forming bottom surface all as specified and directed at site. |
| 101 | Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed at site |
| 102 | Removal of excavated surplus material to a distance n. exc. 50 mtr away in layer n. exc. 25cm from the starting point all as direcet by Engr-in-Charge. |
| 103 | Supply and laying double wall corrugated pipe (DWCP), Non-metallic, resistance to compression : type 450, resistance to impact; normal, resistance to bending: pliable, resistance to external influence; ingress protection: IP 67, resistance against corrosion: without protection, resistance to flame propagation: non flame propagating, nominal outside diameter 77 mm minimum inside dia 63 mm conforming to IS-16205 (part-24) 2017 including necessary jointing material i.e snap fit coupler with rubber ring, sealing plug, tees, bend, angel bend etc for passing electrical cable up to 10 sqmm 4 core complete all as directed. |
| 104 | M & L for boring hole across the Road/plinth/hard standing by trench less technology method suitable for more than 100mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road / Plinth /Floor with 100/80 mm GI pipe complete all as specified and directed. |
| 105 | Supply and Laying G I TUBING 20 mm dia socket ends, Class B medium grade including all fittings and accessories , in any length, fixed on wall / ceiling / roof/laid in floor |
| 106 | S & F stop valve size 20 mm cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both end for iron pipe or for unions and fixed complete all as specified and directed by Engineer-in-Charge. |
| 107 | Supply & fixing evaporative air coolers (desert coolers) as per IS 3315:2019 sump tank capacity not less than 80 liters, single phase having air flow capacity 4000 cum per hrs, cooling efficiency not less than 65 %, maximum power consumption 300 watts, plastic body, noise level not more than 65dBA at 1 m distance, with stand complete all as specified and directed. |
| 108 | Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 109 | M&L for Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge. |
| 110 | S&F of 4.8mm thick sheet glass, ordinary quality and glazing fixed with aluminium beadings in square n exc 0.5 sq. m in each pane |
| 111 | S&F of 4mm thick aluminium partition pannel (APP) fixed to aluminium frame section complete all as specified |
| 112 | S&F 75mm long brass finish SS drawer handle fixed with screws |
| 113 | S&F brass finish SS drawer pad lock of size 30mmx49mmx35mm fixed with screws |
| 114 | S&F 75mm dia PVC desk cable port hole cover fixed to PVC board. |
| 115 | S&F MS telescopic channel of size 300mmx35mm fixed with screws on PVC board drawer. |
| 116 | Material and labour for providing kitchen cabinet and cubboard in required sizes at site made out of 18mm thick PVC sheet (prelam) having one side decorative laminated sheet (for shutter, sides of cabinet, partition and shelves etc). All the edges of shutter and front exposed edge of partition/shelves shall be covered with 2mm thick edge bonding tape as per manufacturer. Including all required fixing material such as SS brackets, screws, adhesive etc., including taking out old any type cabinet complete all as specified and as directed by Engineer-in-charge.Note :- (i) The area of each sheet (shutter, sides of cabinet, partition and shelves) shall be measured in sqm for payment.(ii) Magnetic catcher, handles, continuous Piano hinges and PVC frame (where required) shall be measured and paid separately under appropriate item of BOQ.(iii) Any other material required for making/fixing/hanging of cabinet shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account. |
| 117 | Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20 mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, with Chromium plated brass screws & washers fittings and for 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). |
| 118 | All as per Item No.117 above here in before but for One three pins 5 Amps switch socket outlet point on independent board with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed. (socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). |
| 119 | All as per Item No.117 above here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. (socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). |
| 120 | Description all as per item No.117 above here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.(switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. |
| 121 | Material and labour for concealed Point wiring for one socket out let 5/6 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) ( for cubical office any type/size and concealed in floor including cutting tiles/kota stone etc and finishing should be as existing or on the floor using aluminium/ GI tray with all fitting.) drawn through and including PVC conduit (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, clamp, plug top, raceways/ cable trays, cable clip & ties etc suitable for modular switch socket to be concealed/fixed under desk through conduit /hollow section, including inner and outer plates (cover plate) suitable for fixing the modular switch / socket, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ). |
| 122 | Material and labour for concealed Point wiring for one socket out let 15 Amps point controlled by one switch (on independant board) (using red, black and green colour wires as colour coding) complete with 4 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) ( for cubical office any type/size and concealed in floor including cutting tiles/kota stone etc and finishing should be as existing or on the floor using aluminium/ GI tray with all fitting.) drawn through and including PVC conduit (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, clamp, plug top, raceways/ cable trays, cable clip & ties etc suitable for modular switch socket to be concealed/fixed under desk through conduit /hollow section, including inner and outer plates (cover plate) suitable for fixing the modular switch / socket, including provn of 4 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. complete all as specified and as directed. (switch, socket shall be measured and paid separately under appropriate item of BOQ). |
| 123 | Supply & Fixing modular switch 5/6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 124 | Supply & Fixing modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 125 | Supply & Fixing modular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 126 | Supply & Fixing modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 127 | M&L for Ceiling Rose, surface bakelite 12 to 3 terminal, 240 volts, 5 Amp ISI marked complete all as specified and directed. |
| 128 | S & F of MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 6 to 32 Amps all as specified and directed. |
| 129 | S & F of MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 16 to 40 Amps all as specified and directed. |
| 130 | S & F of RCCBs suitable for 240 volts AC supply, double pole 25A, 30mA with earth leakage protection all as specified and directed. |
| 131 | S& F plug and socket type DB (Functional unit)20 Amps capacity with provision of single pole 20 amps MCB,plug top and earth plug,grouted flush to walls complete all as specified. |
| 132 | S&F Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 12 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed.. |
| 133 | S&F sheet metal enclouser VTPN/HTPN DB having facility to fix MCCB incomer upto 125 Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill protector,insulated bus bar assembly and blanking plates including making good disturbed surfaces complete all as specified and directed. |
| 134 | S&F sheet metal enclouser TPN DB having facility to fix MCB TPN upto 100 amp and MCB in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill protector,insulated bus bar assembly and blanking plates complete all as specified and directed. |
| 135 | S&F and testing LED Glamtube light fitting 1x20watt 4 feet long including LED tube middle round shape with driver complete suitable for fixation on wall/roof with body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 18 watt= 10%, surge protection of minimum 2 KV power factor should be more than 0.90 cool while colour, total hormonic distoration (THD) should not be more than 15% lumen output should not be less than 1700 lumens, total input voltage range 140-280V AC, colour rendering index should not be less than 80, Corelated colour should be minimum 6000 degree Kelvin. |
| 136 | M&L for submain wiring comprising single core ,2 Runs of 10 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits heavy duty and conduit fittings/existing concealed conduit complete, including provision of 1 x 10 sqmm nominal cross sectional area multistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire complete all as specified.( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 137 | Supply and fixing Wall mounting fans complete with 3 blades and accessories, 230 V, 400 mm sweep. Five star rated with brushless direct current motor (BLDC) with remote as specified and recommended by manufacturer all as specified and directed by Engineer in Charge Make : Bajaj/Orient/Crompton, Havells and its equivalent. |
| 138 | M& L for Fasteners hook heavy duty and hook length is not more than 12\\"capacity for ceiling fan to be fixed in the ceiling with suitable tools all as specified. |
| 139 | Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, remote control, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 26W (± 10%), Temperature rise 40 degree maximum with remote, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account |
| 140 | Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe upto test point or upto main switch board, HT/LT equipments, fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top. 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including TMT reinforcement 8mm dia @ 75mm c/c both way, MS handle 12mm dia, cover rest on MS angle iron frame 40x40x6mm embeded in concrete duly painted with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and as directed by Engineer-in-charge.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto test point or upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 141 | S&F for GI frame work for seamless ceiling comprosing of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with GI cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre. |
| 142 | S&F 8.10 mm thick PVC insulation panels with EPS stuck to 1 mm printed PVC sheet suitably placed in false ceiling grid made of aluminium/ G.I/ M.S as per specification and drawing complete all as specified and directed by Engr-in-Charge. |
| 143 | Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface all as spd and directed by Engr-in-Charge. Note: Rate for making good shall be deemed to be included in above item rate. |
| 144 | Material and labour for concealed Point wiring for one light point/fan point /bell point controlled by one switch (using red, black and green colour wires as colour coding) complete with 2.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20 mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, 2mm thick galvanised steel pressed sunken box suitable for modular switch socket (Min 60mm deep, suitable length) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switches/ socket / regulator etc, including provn of 2.5 Sqmm single core FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) complete all as specified and as directed. (switch, socket, regulator shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). |
| 145 | All as per Item No.144 above here in before but for each additional light point on the same switch circuit with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed. |
| 146 | All as per Item No.144 above here in before but for One three pins 5 Amps switch socket outlet point on independent board with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed. (socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). |
| 147 | All as per Item No.144 above here in before but for One three pins 5 Amps switch socket outlet point on same board with other switches with 2.5 Sqmm Copper incl 2.5 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly dolly complete all as specified and directed. (socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ). |
| 148 | Description all as per item No.144 above here in before but for 15 amps socket outlet with 4 Sqmm Copper incl 4.0 Sqmm PVC insulated copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed.(switch, socket shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. |
| 149 | Supply & Fixing modular switch 5/6Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 150 | Supply & Fixing modular Socket outlet multipurpose type 6 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 151 | Supply & Fixing modular Socket outlet multipurpose type 6/16 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 152 | Supply & Fixing modular switch 6/16Amps, single pole, one way (1 module) complete all as specified and as directed by Engineer-in-charge.Note :- Inner/Outer plate for fixing the switch shall be included in point wiring item of BOQ. |
| 153 | S & F of MCB suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA and 6 to 32 Amps all as specified and directed. |
| 154 | S & F of MCB suitable for 240 volts AC supply, SPN with over load and short circuit protection and rupturing capacity not less than 10 KA and 16 to 40 Amps all as specified and directed. |
| 155 | S&F Distribution board double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating surface mounting SPN 8 way 240 volts with bus bar rating 200 Amps dust and vermin proof suitable for incorporation of MCB's and isolators etc complete all as specified and directed.. |
| 156 | S&F sheet metal enclouser VTPN/HTPN DB having facility to fix MCCB incomer upto 125 Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill protector,insulated bus bar assembly and blanking plates including 100 amp MCCB complete all as specified and directed. |
| 157 | S & F for PVC conduit up to 40 mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes, clamp for fixing on wall/ceiling etc to be concealed/fixed in wall/roof/ceiling/ beam/coloumn/false ceiling etc for fixing existing/new wiring/cable/ XPLE cable / telephone & camera cable any type , size and make, complete all as specified and as directed by Engr-in-Charge.Note:- labour for fixing old conduit with any types wire shall deemed to be included in the unit rate and replacing Old cable if any with new is measurable in sepearte items. |
| 158 | S & F for PVC conduit/ PVC pipe more than 40 mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc to be concealed in wall/roof/ceiling/ beam/coloumn etc for fixing existing/new cable/ XPLE cable / telephone & camera cable any type , size and make, complete all as specified and as directed by Engr-in-Charge.Note:- labour for fixing old conduit with any types wire shall deemed to be included in the unit rate and replacing Old cable if any with new is measurable in sepearte items. |
| 159 | M & L cutting chases in wall, pinning in, making god to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, beam etc, cutting chases ( depth as conduit size and width up to 30 cm ) for concealed water tubing/ concealed wiring/ XPLE cable etc, making good disturbed surfaces same as existing of walls/ceiling/floors etc. by using CM (1:3), white wash/ paint/putty etc, taking out old/existing wiring/cable/ telephone & camera cable etc with conduit any type , size and make, with all accessories. complete all as specified and as directed by Engr-in-Charge. |
| 160 | M & L LED for Spot light/ focus light wall mounted 30 W, energy efficient warm white having illumination of 3000 lumen and adjustable neck which can be used to rotate 360 degree including connecting upto with driver 3 core flexible conductor copper of suitable size complete all as specified and directed by Engr-In-charge. |
| 161 | Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 10 Sqmm single core (05 run i.e 4 runs for main 3 phase & 01 neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable 1100 volt drawn through and including PVC conduit 32/40mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed.Note :- Five runs of copper conductor cable and one run of PVC conduit including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate. |
| 162 | M&L for submain wiring comprising single core ,2 Runs of 6 sqmm nominal cross sectional area multistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits heavy duty and conduit fittings, concealed conduit complete, including provision of 1 x 6 sqmm nominal cross sectional area multistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire complete all as specified.( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly) |
| 163 | Supply and fixing warm type LED luminaire 600 mm x 600 mm,36 watt, 220 V AC surface type with high efficiency PMMA diffuser soft glare free light complete with driver suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engr-in-Charge.Make :Bajaj/ Havells/Phillips/Wipro as recommended by Engr-Incharge and approved by GE. |
| 164 | S&F neon strip LED light of warm colour or desired colour with complete driver /connector/adaptor of suitablecap withpower input of DC 2V,6.5W/Mtr consumption and 3000K warm white and 6500K coolday light, 120 LED. 580 lumensper mtr, IP65 surge cap upto 3.5KV approx with heat dessipation of length 50 Mtr roll incl all as specified and directed. |
| 165 | M&L for ceiling light fitting of skylux LED warm type efficient LED surface square/ round as per design type luminaire & galre free soft illumination LED not more than 15 watt white/warm coliur complete suitable for roof ceiling including connecting upto with driver 3 core flexible conductor copper of suitable size complete all asspecified anddirectedby Engr-in-charge |
| 166 | S&F LED profile light of warm colour or desired colour for ceiling / wall / roof / column with complete driver /connector/adaptor of suitable cap including making design on ceiling /wall by professional technician, the design will be finalized by engr -in- charge, power input of DC 2V,6.5W/Mtr consumption and 3000K warm white and 6500K cool day light, 120 LED. 580 lumens per mtr, IP65 surge cap upto 3.5KV approx with heat dessipation roll with all complete fitting all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysSep 02, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 21 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender