Tender For Repair/ Maintenance Of Summer And Winter Appliances I.E, Refrigerators, Water Coolers, Deep Freezers, Air Conditioners, Solar Water Heaters,Voltage Stabilizers And Other E/M Appliances For Jrc Except Mh Area Under Ge (East) Jalandhar Cantt
Tender Overview
Project Description
Tender for Repair/ Maintenance Of Summer And Winter Appliances I.E, Refrigerators, Water Coolers, Deep Freezers, Air Conditioners, Solar Water Heaters,Voltage Stabilizers And Other E/M Appliances For Jrc Except Mh Area Under Ge (East) Jalandhar Cantt (Tender Id No 2026_Mes_783489_1)
BOQ
| Sl. No. | Item Description |
| 1 | M&L for servicing of AC's split type of capacity 1.5 / 2.0 TR inner & outer unit of any make, any type cleaning of outdoor condenser unit, indoor unit cooling coil, with chemical solution and high pressure water jet pump, greasing to condensor fan, checking, tightning all electrical connections, washing of air filter, oiling and tightening of all nut, bolts, etc complete all as directed.Note:AC Indoor and Outdoor unit will be service after taking down from the wall to maintain colour finish distemper/white wash and will be refix at orginal position after servicing.If refrigerant get leak or damage any part during the service it will be the responsibility of contractor for make funtional without any extra cost. |
| 2 | M&L for servicing of AC’s window type of capacity 1.5 / 2.0 TR of any make, any type by taking down AC, cleaning of condenser coil and cooling coils with chemical solution and high pressure water jet pump, greasing to condensor fan, checking, tightning all electrical connections, washing of air filter, oiling and tightening of all nut, bolts etc complete all as directed. |
| 3 | M&L for replacement of compressor sealed unit of capacity 1.5/2.0 TR unit suitable for existing air conditioners window any type, any technology including taking out old unserviceable compressor, cleaning, flushing, vaccumizing the system, charging of suitable refrigerant gas in adequate quantity, soldering, brazing of suction, discharge and charging line complete all as specified and as directed.Make:- Kirloskar/ LG/ Toshiba/ Hitachi/ Carrier/ Tecumseh/ EMERSON/ COPELAND/ WHIRLPOOL/ MITSUBISHI |
| 4 | M&L for replacement of compressor sealed unit suitable for existing air conditioner split type of capacity 1.5/2.0 TR, any technology, any type in outdoor unit including taking out old unserviceable compressor, cleaning flushing, vaccumizing the system, charging of suitable gas in adequate quantity, soldering/ brazing of suction, discharge and charging line complete all as specified and as directed.Make:- Kirloskar/ LG/ Toshiba/ Hitachi/ Gujral/ Carrier/ Tecumseh/ Usha Shri Ram/ EMERSON /COPELAND/ WHIRLPOOL/ Mitsubishi |
| 5 | Supply, replacement, connecting and testing of double shaft blower motor 240 volts, single phase suitable for window type AC 1.5/2 TR as per existing type and size complete all as specified and as directed.Make: Khaitan/ Universal/ CG/ Carrier/ Voltas/ Sidwal/ Airmaster/Crompton. |
| 6 | Supply, replacement, connecting and testing of condenser blower motor suitable for 1.5 /2TR split AC 240 volts single phase, all as directed. Make: Khaitan/ Universal/ CG/ Carrier/ Voltas/ Sidwal/ Airmaster/Crompton. . |
| 7 | Supply, replacement, connecting and testing of indoor blower motor suitable for 1.5/ 2 TR split AC 240 volts single phase, all as directed. Make: Khaitan/ Universal/ CG/ Carrier/ Voltas/ Sidwal/ Airmaster /Crompton. . |
| 8 | Supply, replacement, connecting and testing of indoor blower drum suitable for 1.5/ 2 TR split AC 240 volts single phase, for split AC all as directed. |
| 9 | Supply and replacement of blower drum as per sample suitable for existing 1.5/2 TR Window AC all as directed. |
| 10 | S&F in replacement of temperature sensor as per existing type and size suitable for 1.5/2 TR window/split AC, complete all as specified and as directed. |
| 11 | S&F in replacement of starting/running capacitor suitable for 1.5/2 TR window/split AC , complete all as specified and as directed. Make: Havells/ Unistar/ Asian/ EPCOS/ Sarda/BAJAJ/Tibcon. |
| 12 | M&Lfor charging of refrigerant gas in window type AC 1.5/ 2 Ton capacity including vaccumizing, leakage test and rectification of leakages etc, complete all as specified and as directed. |
| 13 | Ditto all as per item No 12.00 above, but for split type AC of capacity 1.5/ 2 TR, complete all as specified and as directed. |
| 14 | M&Lfor top-up of suitable refrigerant gas (R-22/ R-32/R-410) in split AC/ window type AC 1.5/ 2 Ton capacity to ensure the proper cooling effect etc , complete all as specified and as directed. |
| 15 | S&F in replacement indoor unit of hi-wall split 1.5 Ton including cooling coils, PCB plate and display, remote control, cooling fan motor with blade, blower drum, complete with all accessories suitable for make Voltas/ Blue Star/ Samsung/ LG complete including taking out old unit including cutting, brazing and testing all as specified and as directed. |
| 16 | Ditto all as per item No 15.00 above, but for capacity 2.0 Ton all, complete all as specified and as directed. |
| 17 | M&L for refixing of condensed water pipe line flexible type from cooling unit for drain including necessary clamps, joint reparing with solutions and make it leak proof, complete all as specified and as directed. |
| 18 | S&F in repair MCB single pole 6-32 Amps, B curve10 KA, complete all as specified and as directed. |
| 19 | Repair of Electronic PCB Board for non inverter AC of any make/ any type all as specified and as directed. |
| 20 | Repair of Electronic PCB Board for inverter AC of any make/ any type indoor/ outdoor unit all as specified and as directed. |
| 21 | S&F in replacement universal remote for any make/type of AC all as specified and as directed. |
| 22 | S& F in replacement flare nut of size as per existing including necessary flaring of copper tubing complete incl cutting etc and tightning complete. |
| 23 | S&F in replacement service valve for any make, any type of AC all as specified and as directed. |
| 24 | S&F in replacement PCB remote plate DC operation suitable for AC Window type 1.5 /2 TR of any complete with remote all as specified and as directed. |
| 25 | Supply and fix single pole and neutral sheet metal enclosure with two pin and earth metal plug top and socket complete with and including single pole MCB 20 Amps |
| 26 | S&F in replacement of window AC top cover of size made of 1.6mm thick GI sheet, suitable for AC of capacity 1.5/2.0 TR of make LG/ Voltas/ Sidwal/ Carrier/ Blue star as per site requirement and as specified and as directed. |
| 27 | S&F in replacement of copper pipe for suction line suitable for AC split type of capacity 1.5/2TR including cutting and soldering, brazing etc complete all as specified and as directed. |
| 28 | S&F in replacement of copper pipe for discharge line suitable for AC split type of capacity 1.5/2TR including cutting and soldering, brazing etc complete all as specified and as directed. |
| 29 | S&F in replacement of heavy duty nitrile rubber insulation for suitable for split type AC capacity 1.5/2 TR copper piping with wrapping with packing brown tape including opening pipe connections/ tightning, cutting etc complete all as specified and as directed. |
| 30 | S&F in replacement front grill suitable for AC window mounted type of capacity 1.5/2.0 Ton all as per existing type and size complete all as specified and as directed. |
| 31 | S&F in replacement cooling coil/ condensing coil set made out of copper pipe and fins suitable for window AC of capacity 1.5/2 TR all as per existing type and size including cutting soldering and testing complete all as specified. |
| 32 | S&F in replacement cooling coil/ condensing coil made out of copper pipe and fins suitable for split AC window of capacity 1.5/2 TR all as per existing type and size including cutting soldering and testing complete all as specified. |
| 33 | S&F in repair capillary and filter suitable for AC window/ Split type of capacity 1.5/2 TR including cutting, soldering, brazing etc complete all as specified and as directed. |
| 34 | S&F in repair expansion valve suitable for AC window/ Split type of capacity 1.5/2 TR including cutting, soldering, brazing etc complete all as specified and as directed. |
| 35 | S&F in repair air filter suitable for window/split AC all as directed. |
| 36 | S&F in repair reversible valve 4 way with plunger AC 230 volts 50 c/s as per existing make and type suitable for split/window type AC of capacity 1.5 / 2.0TR including repair/ modification to remote plate, cutting, soldering, brazing complete including charging if gas required to maintain the required pressure complete all as specified and as directed.Note: Cost of all modification required including changes in wiring connections and gas cycle system are deemed to be included in item rate. Nothing shall be paid extra on account of this. |
| 37 | M&L for repairing of voltage stabilizer of capacity 4/5 KVA by opening up and checking the fault, replacing necessary spares and make it functional all as specified and as directed. |
| 38 | M&L for repairing of voltage stabilizer of capacity 1-3 KVA by opening up and checking the fault, replacing necessary spares and make it functional all as specified and as directed. |
| 39 | S&F in replacement of voltage stabilizer copper wounded for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V of capacity 16 Amp rating complete all as specified and as directed.Makes: V-Guard/Blue Star/ Logicstat. |
| 40 | Ditto all as per item No. 39.00 above, but of cap 12 Amp rating. |
| 41 | M&L in replacement PVC insulated and sheathed multi stranded copper conductor wire of size 3 core, 1.5 Sqmm complete all as specified and as directed. |
| 42 | M&L in replacement PVC insulated and sheathed multi stranded copper conductor wire of size 3 core, 2.5 sqmm complete all as specified and as directed. |
| 43 | M&L in replacement PVC insulated and sheathed multi stranded copper conductor wire of size 3 core, 1.0 sqmm, ISI marked complete all as specified and as directed. |
| 44 | Taking down old unserviceable sealed compressor and S&F of new compressor sealed unit suitable for water cooler 150/150 Ltrs capacity including cleaning, vaccumizing, gas charging of adequate quantity and testing on load complete all as specified and as directed.Make: USHA / Sriram /Emerson / Kirloskar/ Carrier/ Tecumseh/ Whirlpool/ EMERSON COPELAND/ Mitsubishi. |
| 45 | Ditto all as per of Srl item No 44.00 above,but sealed unit compressor suitable for water cooler capacity 60/120 Ltrs |
| 46 | Ditto all as per of Srl item No 44.00 above,but sealed unit compressor suitable for water cooler capacity 40/80 Ltrs |
| 47 | M&L for charging of refrigerant gas for water cooler 40 Ltr to 150 Ltrs capacity including cleaning, vaccumizing, detecting and repairing refrigerant leakage, gas charging of adequate quantity and testing on load complete all as specified and as directed. |
| 48 | M&L for repair to body of water cooler/ refrigerator/ deep freezers of any capacity by fixing of SS sheet with angle iron/ MS flat etc all as per existing sizes including cutting, welding, riveting, drilling, bending to shape etc, at site including grinding, finishing and applying of one coat of primer complete all as specified and as directed.Note : Transportation of equipments/ T&P required at site will be responsibility of the contractor, nothing shall be paid extra on this account. |
| 49 | S&F in repair desert cooler stand made out of MS angle iron of size as directed including cutting and welding, painting with two coat of synthetic enamel paint over a coat of red oxide primer all as directed. |
| 50 | Supply and replacement of water tap brass CP with inner/outer threads push type or with rotary knob of size 15 mm / 20mm dia as per existing type and size complete all as specified and as directed. |
| 51 | S&F in replacement of thermostat switch suitable for water coolers complete all as specified and as directed.Make : Danfoss/ Renutrol/ Indfoss or equivalent |
| 52 | S&F in replacement of starting relay suitable for water coolers of capacity 150 Ltrs/120 Ltr/80Ltr/40 Ltr complete all as specified and as directed.Make :- Danfoss/Renutrol/ Indfoss or equivalent. |
| 53 | S&F in replacement of starting/running capacitor suitable for water coolers 150 ltrs/120 Ltr/80Ltr/40 Ltr complete all as specified and as directed.Make :- USHA/UNIVERSAL/ HAVELLS/EPCOS/ sarda or equivalent. |
| 54 | S&F in replacement of overload protector suitable for water cooler of capacity 150/120/80 Ltrs complete all as specified and as directed.Make :- Danfoss/Renutrol/ Indfoss or equivalent. |
| 55 | S&F in replacement fin type condenser with copper pipes suitable for water cooler of capacity 40/80 Ltr to 60/120 Ltr as per existing type and size including cutting, soldering/ brazing etc complete all as specified and as directed. |
| 56 | Ditto all as per item No. 55.00 above, but of capacity 150/150 Ltrs. |
| 57 | Taking down old and unserviceable sealed compressor and S&F new sealed compressor unit for refrigerator of capacity 250 to 360 Ltrs including cleaning, vaccumizing, suitable gas charging adequate qty in the unit and soldering/ brazing of suction and discharge and charging line complete all as specified and as directed.Make: Kirloskar/ LG/ Voltas/ Godrej/ Hitachi/ Toshiba/ Carrier/EMERSON COPELAND/ WHIRLPOOL |
| 58 | Ditto all as per item No 57.00 above but for Refg of capacity 165-240 Ltr . |
| 59 | Taking down old and unserviceable sealed compressor and S&F new sealed compressor unit for deep freezer of capacity 400-500 Ltrs including cleaning, vaccumizing, gas charging of adequate qty in the unit and soldering/ brazing of suction and discharge and charging line complete all as specified and as directed.Make: Kirloskar/ LG/ Voltas/ Godrej/ Hitachi/ Toshiba/ Carrier. |
| 60 | Ditto all as per item No 59.00 above but for deep freezer of capacity 200-320 Ltr . |
| 61 | S&F of evaporative coil ( cooling coil ) of refrigerators of capacity 260-360 Ltrs as per existing type and size including cutting, taking out to old coil, brazing/ soldering and testing complete all as specified and as directed. |
| 62 | Ditto all as per item No 61.00 above but for refrigerator of capacity 165-230 Ltr . |
| 63 | S&F magnetic door gasket suitable for refrigerator of capacity 165 to 360 Ltrs as per existing type and size complete all as specified and as directed. |
| 64 | S&F thermostat switch suitable for refrigerator of capacity 165 to 360 Ltrs as per existing size and type complete all as specified and as directed.Make :- Danfoss/ Renutol/ Indfoss or equivalent. |
| 65 | S&F of starting relay with over load protector kit complete as per existing size and type complete all as specified and directed Make :- Danfoss/ Renutol/ Indfoss or equivalent. |
| 66 | M&L for repair of PCB of double door refrigerator all as directed. |
| 67 | M&Lfor charging refrigerant gas of existing type in refrigerator of capacity 165 to 360 Ltr including vaccumizing, leakage test and rectification of leakage etc complete all as specified and as directed. |
| 68 | Ditto all as per item No 67 above but for deep freezer of capacity 200 Ltr-500Ltr . |
| 69 | S&F in replacement cooling motor with fan suitable to operate on AC, 220/240 volts, 50 c/s complete with frame all as per existing size/type suitable for water cooler any capacity all as specified and directed |
| 70 | M&L for condensing coil fan motor suitable for deep freezer 200 Ltr to 500 Ltr cap complete. |
| 71 | M&Lfor top-up refrigerant gas of existing type in refrigerator of capacity 165 to 360 Ltr/ Deep feezer 200 Ltr to 500 Ltr and water cooler any cap including with reqd wk complete all as specified and as directed. |
| 72 | M&L for de-scaling of collector unit and piping complete and testing of solar water heaters of capacity 100 to 300 LPD complete all as specified and as directed. |
| 73 | M&L for de-scaling of collector unit and piping complete and testing of solar water heaters of capacity 400/500 LPD complete all as specified and as directed. |
| 74 | M&L for de-scaling of collector unit and piping complete and testing of solar water heaters of capacity 1000 LPD complete all as specified and as directed. |
| 75 | S&F in repair of solar water heating element 3 KW Single phase, 230 Volts, as per existing type and size complete all as specified & directed. |
| 76 | S&F thermostat switch suitable for solar water heater of capacity 100-1000 LPD all as per specified as per existing type and size complete all as specified & directed. |
| 77 | S&F in repair heat collector toughened glass of any size suitable for solar water heaters of capacity 100-1000 LPD as per existing type and thickness as per existing complete incl cutting to size, fixing with suitable adhesive complete all as specified & directed |
| 78 | M&L for replacement of copper pipe of exiting size/ dia for header in collector of solar water heaters of capacity 100 LPD to 1000 LPD including cutting, soldering, insulation and testing complete all as specified and as directed. |
| 79 | M&L painting of solar water heater MS structure by removing of old paint and preparing surfaces for repainting and applying two coats of synthetic enamel paint complete all as specified and as directed. |
| 80 | Lagging to pipes used in internal water supply or plumbing all round with, 25min thick bonded mineral wool preformed ‘SNAP ON’ pipe sections of density 144 Kg/cum conforming to IS 9842 and all around covered with jute cloth and tape complete suitable for pipe of dia 15 to 25mm dia bore complete. |
| 81 | M&L for aluminium cladding 0.46 mm to 0.6 mm thickness for covering glass insulation complete all as directed |
| 82 | M&L for Tubes, 'medium grade' galvanised, in replacement with all fitting and fixed complete to walls and ceilings or laid in floors of size 15mm bore. |
| 83 | M&L for Tubes, 'medium grade' galvanised, in replacement with all fitting and fixed complete to walls and ceilings or laid in floors of size 20mm bore. |
| 84 | M&L for Tubes, 'medium grade' galvanised,in replacement with all fitting and fixed complete to walls and ceilings or laid in floors of size 25mm bore. |
| 85 | M&L for Gun-metal, globe or gate valves,in replacement with iron wheel head, screwed both ends for iron pipe and fixed of size 20 mm bore. |
| 86 | M&L for Gun-metal, globe or gate valves, in eplacement with iron wheel head, screwed both ends for iron pipe and fixed of size 25 mm bore. |
| 87 | S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 500 ltrs all as specified in SSR Part I. |
| 88 | S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 1000 ltrs all as specified in SSR Part I. |
| 89 | M&L painting of desert cooler internally and externally complete including removing of old paint and preparing surfaces for painting and applying two coats of synthetic enamel paint by using spray gun complete all as specified and as directed. |
| 90 | S&F front air grill of desert cooler complete as per existing type and size all as specified and as directed. |
| 91 | S&F in replacement of desert cooler fan motor 1/8 HP, copper wound, three speed with suitable cap capacitor suitable for desert cooler complete all as specified and as directed.Make: Universal/ Khaitan/ CG/bajajAirmaster |
| 92 | S&F in replacement of submersible water pump of capacity 18 watt, single phase, 220 V suitable head and flow for desert cooler with connecting wire complete all as specified and as directed.Make: Universal/ Khaitan /CG/Havells |
| 93 | S&F in replacement of desert cooler PVC pipe 1 Mtr min from water pump to PVC distributor incl PVC distributor and 3 Nos PVC bend complete all as specified and as directed. |
| 94 | S&F in replacement Wood wool pad (superior quality) at site for desert cooler any size / cap complete all as specified and as directed. |
| 95 | S&F in replacement Starting capacitor 4.0 mfd heavy duty suitable for desert cooler complete all as specified and as directed. |
| 96 | S&F in replacement Starting capacitor 2.5 mfd heavy duty suitable for AC fan motor , complete all as specified and as directed. |
| 97 | M&L for replacement of outer body of desert cooler as per existing type and size of standard size having 3 side coverS&Front cover made of 24 gauge GI sheet, front grill with sheet for mounting of switches suitable for desert cooler of capacity 4000 Cum/Hr duly painted complete internally and externally with two coats of super enamelled paint over a coat of red oxide primer all as specified and as directed. |
| 98 | M&L for replacement of tank of 1mm thick sheet min, suitable for desert cooler of capacity 4000 Cum/Hr duly painted complete internally and externally with two coats of super enamelled paint over a coat of red oxide primer all as specified and as directed. |
| 99 | S&F in repairs switch piano flush type, 5 Amps, AC single pole, one way complete all as specified. |
| 100 | S&F repairs switch piano flush type, 15 Amps, AC single pole, one way complete all as specified. |
| 101 | S&F in repairs socket out let 5 Amp, 5 pin flush type complete all as specified. |
| 102 | S&F in repairs Socket outlet multi purpose 2 in 1, 3 pin, 5 & 15 Amps, flush type complete all as specified |
| 103 | S&F in replacement Top plug 6 Amp all as specified and as directed. |
| 104 | S&F in replacement Top plug 16 Amp all as specified and as directed. |
| 105 | S&F in replacement outdoor unit of hi wall split of capacity 1.5 Ton including condenser coil copper, with cooling fins, condensor blower motor with blades, PCB plate with complete wiring, including compressor, charging of refrigerent gas, testing and commissioning of Make: Blue Star/ Samsung/ LG complete including taking out old unit including cutting, brazing and testing all as specified and as directed. |
| 106 | Ditto all as per item No 105.00 above, but outdoor unit of capacity 2.0 TR. |
| 107 | Supply and fix in replacement for CPVC pipe SDR 11 for drain pipe of ACs condensed water fixed complete to walls, ceilings or in floors etc. of size 40mm dia along with sockets, Tees, Bends, Elbows,wall clamps, necessary joining material other accessories required for fixing of pipe with wall/floor all as specified and as directed. |
| 108 | Ditto all as per srl item no. 107 above but of size 25 mm dia. |
| 109 | Taking down existing Split AC 1.5/2.0 TR indoor unit and out door unit complete by disconnecting, storing refrigerant in suction and discharge lines, opening nuts and bolts taking out brackets of indoor and outdoor unit from walls, taking out Voltage stabilizer from wall, reinstall to another location without damaging the AC and testing , complete all as specified and as directed. |
| 110 | S&F in replacement Brackets for fixing split AC 1.5/2.0 TR out door unit with walls made of MS duly powder coated factory made with bolts, nuts and washers and 04 Nos of fasteners complete all as specified and as directed. |
| 111 | S&F in replacement Floor Stand for fixing split AC 1.5/2.0 TR out door unit made of MS duly powder coated factory made with bolts, nuts and washers and 04 Nos fastners complete all as specified and as directed. |
| 112 | M&L for shifting of window type AC 1.5 / 2.0 TR by taking out AC from one room and shifting it to another location within 500 mtr and fixing it at place where directed by department all as specified and as directed. |
| 113 | M&L for sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 6.0 Sqmm drawn through in and including in existing concealed conduit (medium grade) with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multistranded copper conductor cable 6.0 Sqmm ( green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface complete all as specified. NOTE: Two run of 6.0 sqmm wire and one run of 6.0 sqmm wire as earth wire ishall be measured as one unit. |
| 114 | M&L for sub main wiring with two run of single core FRLS PVC insulated unsheathed multistranded copper conductor cable of 4.0 Sqmm drawn through in existing concealed conduit with all fittings including earth continuity single wire FRLS PVC insulated unsheathed multistranded copper conductor cable 4.0 Sqmm ( green insulation) with any type of civil work including making good to disturbed surfaces to match existing surface complete all as specified. NOTE: Two run of 4.0 sqmm wire and one run of 4.0 sqmm wire as earth wire including shall be measured as one unit. |
| 115 | Supply, laying, testing and commisioning in replacement of Service wire made of PVC insulated sheathed, electric cables ( heavy duty) 1100 volts grade with aluminium conductor of size 4.0 sq mm 2 core complete. |
| 116 | Supply, laying, testing and commisioning in replacement of Service wire PVC insulated sheathed electric cables ( heavy duty) 1100 volts grade with aluminium conductor of size 6.0 sq mm 2 core complete. |
| 117 | M&L for cleaning/descaling of geyser of capacity 25/35/50 ltr of any make, with chemical solution, checking, tightning all electrical connections, all nut, bolts, etc complete all as directed. |
| 118 | S&F in repairs of metal clad industrial plug top 20 Amps, 250 V, 2 pole with earth suitable for geyser/ AC complete all as specified & directed. |
| 119 | S&F in repairs of metal clad industrial socket 20 Amps, 2 pole with earth suitable for geyser/ AC complete all as specified & directed. |
| 120 | Supply, installing, commissioning and testing of electric water heater (Geyser) storage type ABS body of capacity 25 litres, BEE approved 5 Star rating, 230 V , single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection 450mm long heavy duty suitable for Hot and cold water, three core PVC insulated PVC Sheathed copper conductor flexible cable, 04 Nos suitable size mild steel L-Hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge.Note:Old UNSV geyser will be deposit in MES store yard for BER |
| 121 | Taking down geyser any capacity by disconnecting hot and cold water connection and refixing the geyser with new fasteners all as specified and as directed. |
| 122 | S&F in replacement geyser inner water tank S/S suitable for Geyser Capacity 50 Ltrs as per existing shape and type complete all as specified & directed. |
| 123 | S&F in replacement geyser inner water tank S/S suitable for Geyser Capacity 25 Ltrs as per existing shape and type complete all as specified & directed. |
| 124 | S&F in replacement geyser assembly brass C P type 9/6/8 hole with gasket as per existing type and size complete suitable for geyser 25/50 Ltr all as specified & directed. |
| 125 | S&F in replacement multifunction safety valve for geyser any capacity. |
| 126 | S&F in repairs thermostat adjustable type suitable for geyser 25/35/50 Ltr capacity complete all as specified and directed |
| 127 | S&F in repairs geyser heating element triangle/ cup type 1.5/2 KW with gasket complete all as specified and directed |
| 128 | S&F in repairs geyser heating element triangle/ cup type 2.0 KW with gasket complete for make VENUS geyser models all as specified and directed |
| 129 | S&F in repairs hot & cold PVC flexible water connection 600mm long with brass ends nuts suitable for geysers complete all as specified and directed |
| 130 | S&F in repairs hot & cold PVC flexible water connection, 450mm long with brass ends nuts suitable for geysers complete all as specified and directed |
| 131 | S&F in repair CP bib cock 15mm dia all as specified and as directed. |
| 132 | S&F in repair CP stop cock 15mm dia with male/ female threads all as specified and as directed. |
| 133 | S&F in repair Desert cooler fan blade (aluminium blades) 500 mm sweep dia all as specified and as directed. |
| 134 | S&F in replacement of Electronic PCB Board for Split AC indoor unit any cap (inverter type) of any make/ any type all as specified and as directed. |
| 135 | S&F in replacement of Electronic PCB Board for Split AC outdoor unit any cap (inverter type) of any make/ any type all as specified and as directed. |
| 136 | S&F in repairs cylindrical type hot water tank of capacity 1000 Ltrs made food grade stainless steel 304,1.6 mm thick, layered with a galvanized steel shell on the outside duly insulated with 50mm thick PUF of 40 kg / cum density min with a standard screw-in port for electrical backup heating element, suitable nipple for inlet, outlet, drain, overflow water connection, or any other item required as per site condition including cladding as per existing design with supporting legs complete all as specified and as directed. |
| 137 | S&F in repairs cylindrical type hot water tank of capacity 500 Ltrs made food grade stainless steel 304, 1.6 mm thick, layered with a galvanized steel shell on the outside duly insulated with 50mm thick PUF of 40 kg / cum density min with a standard screw-in port for electrical backup heating element, suitable nipple for inlet, outlet, drain, overflow, water connection any other item required as per site connection including cladding as per existing design with supporting legs complete all as specified and as directed. |
| 138 | S&F in repairs cylindrical type hot water tank of capacity 300 Ltrs made food grade stainless steel 304, 1.6 mm thick, layered with a galvanized steel shell on the outside duly insulated with 50mm thick PUF of 40 kg / cum density min with a standard screw-in port for electrical backup heating element, suitable nipple for inlet, outlet, drain, overflow, water connection any other item required as per site connection including cladding as per existing design with supporting legs complete all as specified and as directed. |
| 139 | M&L for black hose pipe suitable for hot water upto 80 degree centigrade having bore size 1 inch complete all as specified |
| 140 | M&L for block hose pipe suitable for hot water upto 80 degree centigrade having bore size 1.5 inch complete all as specified |
| 141 | M&L for stainless steel clamp (worm drive adjustable type) of size suitable for 1.5'' outer dia complete all as specified |
| 142 | M&L for stainless steel clamp (worm drive adjustable type) of size suitable for 2'' outer dia complete all as specified |
| 143 | M&L for replacement of metallic outer body with adequate glass wool for geyser of cap 25 ltrs as per existing type duly powder coated paint complete all as specified and as directed. |
| 144 | M&L for replacement of metallic outer body with adequate glass wool for geyser of cap 50 ltrs as per existing type duly powder coated paint complete all as specified and as directed. |
| 145 | M&L rubber gasket suitable for solar water heater connection jointing plate including nuts and bolts complete all as specified. |
| 146 | S&F in repairs hot & cold CP flexible water steel connection, 300mm long with brass ends nuts suitable for geysers complete all as specified and directed |
| 147 | M&L for Float valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed for 15mm dia bore pipe complete. |
| 148 | M&L for Ball valves, high pressure, complete with lever, screwed for iron pipe or brass ferrule and fixed for 15mm dia bore pipe complete. |
| 149 | M&L for freezer assy for refrigerator of cap 200 Ltr to 330 Ltr complete. |
| 150 | Supply and Installation of Desert cooler plastic body of size 65.5 x 63.4 x 77.3 cm or next available higher size, electric driven single phase 240 volts, 110 W complete all as specified and idrected by engr in charge Note: (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.(b) Serial Number as issued by Engr-In-Charge of cooler and GE Office name shall also be written on cooler with red colour permanent marker or paint, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.Neccesary TSS of product will be approved by GE before purchase Note:Old UNSV desert cooler will be deposit in MES store yard for BER Make:Bajaj ,Crompton |
| 151 | Removing of old burnt winding from Desert cooler motor any size, any type (copper/ aluminium), cleaning stator complete for burnt wiring, carbon residue and rewinding of stator by winding of any type/any make fan/ any stator design with superior quality super enameled winding copper wire of existing specification, gauge and weight with superior quality insulation for satisfactory functioning in presence of JE incharge complete all as directed by Engr-in-Charge |
| 152 | Supply, installing, commissioning and testing of electric water heater (Geyser) storage type ABS body of capacity 50 litres, BEE approved 5 Star rating, 230 V , single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection 600mm long heavy duty suitable for Hot and cold water, three core PVC insulated PVC Sheathed copper conductor flexible cable, 04 Nos suitable size mild steel L-Hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge.Note:Old UNSV geyser will be deposit in MES store yard for BER Please Enable Macros to View BoQ information |
| 153 | Supply, installing, commissioning and testing of electric water heater (Geyser) storage type ABS body of capacity 50 litres, BEE approved 5 Star rating, 230 V , single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) with glass lined coating complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection 600mm long heavy duty suitable for Hot and cold water, three core PVC insulated PVC Sheathed copper conductor flexible cable, 04 Nos suitable size mild steel L-Hook fastener with washer for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge.Note:Old UNSV geyser will be deposit in MES store yard for BER Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 23 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender