Tender For Supply Installation Testing and Commissioning of Hot And Cold Dc Inverter Type Split Type Air Conditioners At Jodhpur House New Delhi.
Tender Value
16.80 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
1 days left
EMD
33600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply Installation Testing and Commissioning of Hot And Cold Dc Inverter Type Split Type Air Conditioners At Jodhpur House New Delhi.
BOQ
| Sl. No. | Item Description |
| 1 | Part A Non BSR |
| 2 | Approved By CE(Elect.)/NON-BSR/2026-27/D-388 dated 30.07.2026. |
| 3 | Supply, Installation, Testing & Commissioning of 1.5 TR High Wall Split Type Hot & Cold Inverter Air Conditioner complete with indoor unit, outdoor unit, wireless remote controller, factory charged refrigerant (R-32/R-410A), copper condenser and evaporator coils, inverter rotary/twin rotary compressor, suitable for cooling and heating operation, operating on 230V ±10%, 50Hz, Single Phase, minimum 4-Star BEE rating, ISEER not less than 4.5, nominal cooling capacity 5.2–5.3 kW (1.50 TR), nominal heating capacity 5.2–5.8 kW, cooling operating ambient temperature up to 55°C, heating operation up to -15°C, tropical compressor suitable for Indian climatic conditions, anti-corrosion blue fin/epoxy coated heat exchanger, washable anti-bacterial/anti-mould/PM2.5 air purification filter, auto restart, self-diagnosis, sleep mode, timer, turbo mode, dehumidification mode, automatic horizontal and vertical swing, minimum 5-speed indoor fan, low noise operation (maximum 45 dB(A)), indoor air flow not less than 1100 m³/hr, maximum piping length not less than 20 m, maximum level difference not less than 12 m. The unit shall include factory charged refrigerant for 3 m insulated copper refrigerant piping (liquid & gas line), condensate drain pipe, interconnecting power and control cable, outdoor mounting stand/wall bracket with anti-vibration pads, all accessories, nitrogen pressure testing, vacummisation, refrigerant topping wherever required, testing and commissioning complete as required. (Copper Piping with insulation, drain pipe paid separately). (Complete rate - 83359 including GST) |
| 4 | Approved By CE(Elect.)/NON-BSR/2026-27/D-388 dated 30.07.2026. |
| 5 | Supply, Installation, Testing & Commissioning of 2.0 TR High Wall Split Type Hot & Cold Inverter Air Conditioner complete with indoor unit, outdoor unit, wireless remote controller, factory charged refrigerant (R-32/R-410A), copper condenser and evaporator coils, inverter rotary/twin rotary compressor, suitable for cooling and heating operation, operating on 230V ±10%, 50Hz, Single Phase, minimum 3-Star BEE rating, ISEER not less than 4.2, nominal cooling capacity 7.0–7.2 kW (2.0 TR), nominal heating capacity 7.0–8.2 kW, cooling operating ambient temperature up to 55°C, heating operation up to -15°C, tropical compressor suitable for Indian climatic conditions, anti-corrosion blue fin/epoxy coated heat exchanger, washable anti-bacterial/anti-mould/PM2.5 air purification filter, auto restart, self-diagnosis, sleep mode, timer, turbo mode, dehumidification mode, automatic horizontal and vertical swing, minimum 5-speed indoor fan, low noise operation (maximum 50 dB(A)), indoor air flow not less than 1500 m³/hr, maximum piping length not less than 30 m, maximum level difference not less than 12 m. The unit shall include factory charged refrigerant for 3 m insulated copper refrigerant piping (liquid & gas line), condensate drain pipe, interconnecting power and control cable, outdoor mounting stand/wall bracket with anti-vibration pads, all accessories, nitrogen pressure testing, vacummization, refrigerant topping wherever required, testing and commissioning complete as required. (Copper Piping with insulation, drain pipe paid separately). (Complete rate - 100434 including GST) |
| 6 | Part B- BSR 2025 Items |
| 7 | Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM must ensure that the cable is tested for complaince, either through their in house laboratory accrediated by NABL or by any Govt. laboratory accrediated by NABL and the laboratory's scope of accrediation should cover the requirements and testing procedure as per IS:10810. |
| 8 | Un Armoured |
| 9 | 4 core x 2.5 Sq.mm |
| 10 | Providing & Fixing of IS : 4985 - 2000 Class -4 (10 Kgf / Sqcm) UPVC drain water piping with fittings (IS:7834 & 10Kgf/sqcm) like elbow, socket, Tee, solvent cement jointing, support with MS hanger on ceiling or recessed in wall with chasing & plastering with 6 mm thick closed cell elastomeric nitrile rubber insulation including leakage testing etc. as required of following Nominal sizes. |
| 11 | 25 mm |
| 12 | Making hole in stone masonary/ RCC wall/ RCC slab with core cutter for accomodating refrigerant pipe/ drain pipe/ MS pipe/ cables etc of following dia |
| 13 | 100 mm dia per running inch length |
| 14 | Supply & fixing MS powder coated stand suitable for 1.0/1.5/ 2.0 Tr outdoor type of Split AC. All as per pre approved by Engineer in charge. |
| 15 | SITC of Interconnecting refrigerant copper pipe for split/Ductable/ Casseette AC of DHE Grade C12200- ASTM B68, B75, chemical composition of copper %- 99.0 Min and Phosphorus %- 0.015 to 0.040 . For Annealed copper tube :- Tensile strength = 210 Mpa wih elongation % = 40 Min . Ink Mark Brand Printing on Hard Tubes should be present. Piping between each set of indoor & outdoor units of different sizes as per OEM requirement & specifications including class 'O' Nitrile rubber sleeves (size as per item no. 22.43),7 mil Glass Cloth with 3 coats of anti UV paint (on area which is exposed to weather) chase cutting, supports, making good the same with sand cement plaster etc. as required. |
| 16 | P&F metal clad / Polyamide industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet , powder coated conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. (without MCB) including making connections, testing etc.as required. |
| 17 | 20 amp, (2P + E), 1 Module |
| 18 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 25 sq.mm., conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating, 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. |
| 19 | Single pole MCB (With B / C curve tripping characteristics) |
| 20 | 6 A to 32 A rating |
| 21 | Add GST (18%) on Total Costruction Cost Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayAug 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 2 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender