Housing Urban and Rular Development Local Bodies Closing in 2 days TDR #56939269

Tender For Conservation Of Water Body Under North Zone. Sh:- Supply Installation Testing and Commissioning of Poles And Its Accessories Alongwith Repairing Of E/M Installation At Water Bodies Situated At Different Location Under North Zone.

Issued by Local Bodies · Delhi, Delhi
Tender Value
1.81 Crore
Estimated cost
Bid Submission
18 Aug 2026
2 days left
EMD
3.62 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Conservation Of Water Body Under North Zone. Sh:- Supply Installation Testing and Commissioning of Poles And Its Accessories Alongwith Repairing Of E/M Installation At Water Bodies Situated At Different Location Under North Zone.

BOQ

Name of Work:- Conservation of water body under North Zone. SH:- SITC of poles and its accessories alongwith repairing of E/M installation at water bodies situated at different location under North Zone.
Sl. No. Item Description
1Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: DELHI DEVELOPMENT AUTHORITY Name of Work:-Conservation of water body under North Zone. SH:- SITC of poles and its accessories alongwith repairing of E/M installation at water bodies situated at different location under North Zone. Contract No: 23/EE/ELD-8/DDA/2026-27 05/SE(E )/NZ/DDA/2026-27 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Rs. P TOTAL AMOUNT TOTAL AMOUNT In Words
2Supplying, installation, testing and commissioning of HOT Dip galvanized octagonal steel pole of 7 mtr height and made of 3 mm thick sheet, having bottom 130 mm OAF & top 70 mm OAF provided with welded base plate of size 220 mm x 220 mm x 12 mm thick with built in connector control box of 1 meter above the base plate complete with 250 mm wide 3 mm thick hot dip galvanised MS strip in octagonal shape welded permanenty around on window cover/junction box i/c providing L-hook just below the M.S. strip provided on junction box/cover box of suitable projection from the pole shaft to prevent the movable junction/cover box going down to the base plate and making a suitable size of hole on above (300 mm approx) of junction /cover box to hold the junction/cover box during the maintenance i/c covering with MS cover arrangement the hole to prevent entry of rain water through it, complete as per drawing & technical specifications attached & providing following accessories with mounted inbuilt control box having flush cover with 2 nos. mounting strips with tapped holes on existing RCC foundation with bolt and nuts, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking/ numbering of pole etc. complete as per drawing & technical specifications attached including following accessories with mounted inbuilt control box. (a). 6mm thick phenolic laminated/Bakelite sheet inside the window mounted on the existing mounting strips inside the flush door.(b). 1 no. 63 Amp terminal block suitable for following conductor / cable, fixed on DIN channels i/c providing and fixing DIN channel of suitable length – on the existing phenolic laminated / Bakelite sheet.(i) 16 sq mm conductor – 2 nos. (incoming and outgoing looping) (ii) Terminal suitable for 6 SWG GI wire / 2.5 sq mm wire.(c). 6 Amp, SP MCB,10 KA, ‘C’ Series – 1 no. including mountings on DIN channel, Earth stud 2 Nos. welded at suitable height i/c washers, springs washers & nuts etc. (d) Suitable arrangement for saddling of incoming / outgoing cables.
3Supplying, replacement, testing and commissioning of HOT Dip galvanized octagonal steel pole of 6 mtr height and made of 3 mm thick sheet, having bottom 130 mm OAF & top 70 mm OAF provided with welded base plate of size 220 mm x 220 mm x 12 mm thick inbuilt control box 1.0 mtr above the base plate, complete with 250mm wide 3 mm thick hot dip galvanised MS strip in octagonal shape welded permanenty around on window cover/junction box i/c providing L-hook in opposite side of control box just below the M.S. strip provided on juncion box/cover box of suitable projection from the pole shaft to prevent the movable junction/cover box going down to the base plate and making a suitable size of hole on above the L-hook (300 mm approx) to hold the junction/cover box during the maintenance i/c covering with MS cover arrangement the hole to prevent entry of rain water through it, complete as per drawing & technical specifications attached & providing following accessories with mounted inbuilt control box having flush cover with 2 nos. mounting strips with tapped holes on existing RCC foundation with bolt and nuts, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking/ numbering of pole etc. complete as per drawing & technical specifications attached including following accessories with mounted inbuilt control box.(a). 6mm thick phenolic laminated/Bakelite sheet inside the window mounted on the existing mounting strips inside the flush door.(b). 1 no. 63 Amp terminal block suitable for following conductor / cable, fixed on DIN channels i/c providing and fixing DIN channel of suitable length – on the existing phenolic laminated / Bakelite sheet.(i) 10 sq mm conductor – 2 nos. (incoming and outgoing looping) (ii) Terminal suitable for 6 SWG GI wire / 2.5 sq mm wire.(c). 6 Amp, SP MCB,10 KA, ‘C’ Series – 1 no. including mountings on DIN channel, Earth stud 2 Nos. welded at suitable height i/c washers, springs washers & nuts etc. (d) Suitable arrangement for saddling of incoming / outgoing cables.
4Supplying, replacement, testing and commissioning of HOT Dip galvanized octagonal steel pole of 4 mtr height and made of 3 mm thick sheet, having bottom 130 mm OAF & top 70 mm OAF provided with welded base plate of size 200 mm x 200 mm x 12 mm thick inbuilt control box1.0 mtr above the base plate, complete with 250mm wide 3 mm thick hot dip galvanised MS strip in octagonal shape welded permanenty around on window cover/junction box i/c providing L-hook in opposite side of control box just below the M.S. strip provided on juncion box/cover box of suitable projection from the pole shaft to prevent the movable junction/cover box going down to the base plate and making a suitable size of hole on above the L-hook (300 mm approx) to hold the junction/cover box during the maintenance i/c covering with MS cover arrangement the hole to prevent entry of rain water through it, complete as per drawing & technical specifications attached & providing following accessories with mounted inbuilt control box having flush cover with 2 nos. mounting strips with tapped holes on existing RCC foundation with bolt and nuts, making connections, interconnections with suitable size of copper wire with thimble/lugs in the connector box, earthing, marking/ numbering of pole etc. complete as per drawing & technical specifications attached including following accessories with mounted inbuilt control box.(a). 6mm thick phenolic laminated/Bakelite sheet inside the window mounted on the existing mounting strips inside the flush door.(b). 1 no. 63 Amp terminal block suitable for following conductor / cable, fixed on DIN channels i/c providing and fixing DIN channel of suitable length – on the existing phenolic laminated / Bakelite sheet.(i) 10 sq mm conductor – 2 nos. (incoming and outgoing looping) (ii) Terminal suitable for 6 SWG GI wire / 2.5 sq mm wire.(c). 6 Amp, SP MCB,10 KA, ‘C’ Series – 1 no. including mountings on DIN channel, Earth stud 2 Nos. welded at suitable height i/c washers, springs washers & nuts etc. (d) Suitable arrangement for saddling of incoming / outgoing cables.
5Providing and laying in position, M25 reinforced cement concrete foundation of size 450 mm (L) x 450 mm (W) and 1000 mm (D) i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia. 1000 mm long (approx.) – atleast 8 Nos. and reinforcement ring of cold twisted bar of 10 mm dia. 1800 mm long (approx.)- atleast 10 Nos. (with 100 mm spacing) i/c supplying of 4 Nos. M-16 x 650 mm long (150 mm top threaded & whole galvanized portion) M.S foundation bolt (EN 8-grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with 2 Nos. templates/Anchor plate of size 200 mm x 200 mm x 12 mm thick having 4 Nos.16 mm dia. holes to match with PCD of poles base plate with positioning of foundation bolts and providing 75 mm (OD) 2 Nos. DWC pipe for cable entry/exit, plastering & painting the foundation above the ground level etc complete as required.
6Providing and laying in position, M25 reinforced cement concrete foundation of size 500 mm (L) x 500 mm (W) and 1400 mm (D) i/c excavation of earth, providing cutting, bending and placing in position reinforcement of cold twisted bar of 12 mm dia. 1400 mm long (approx.) – atleast 8 Nos. and reinforcement ring of cold twisted bar of 10 mm dia. 2000 mm long (approx.)- atleast 10 Nos. (with 150 mm spacing) i/c supplying of 4 Nos. M-20 x 700 mm long (150 mm top threaded & 250 mm top galvanized portion) M.S foundation bolt (EN 8-grade) with 3 Nos. nuts and 2 Nos. washer, bolt along with 2 Nos. templates/Anchor plate of size 220 mm x 220 mm x 4 mm thick having 4 Nos.20 mm dia. holes to match with PCD of poles base plate with positioning of foundation bolts and providing 63 mm (OD) 2 Nos. DWC pipe for cable entry/exit, plastering & painting the foundation above the ground level etc complete as required.
7Supplying, installation, testing & commissioning of floor mounted free standing type L.T. cubical main feeder pillar (outdoor type) with 200 Amps4 strips Al. bas bars, cable alleys , IP:54 rating dust and B20varmin proof duly compartmentalized suitable to accommodate the incoming and outgoing switch gears, made out of 2mm thick MS CRCA sheet i/c providing 40 mm x 40 mm x 5 mm thick MS angle iron frame work all around for mounting 4 nos. x 750 mm long 40 mm x 40 mm x 5 mm thick angle iron legs suitably grouting in CC foundation of 1:2:4 ( 1 Cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size with 750 mm deep ( 450 mm in ground and 300 mm above ground level and foundation size exceeding 150 mm on all sides of feeder pillar baseand connections, inter connections with suitable rating copper wires/strips, thimbles/lugs, earthing the body, painting etc complete with following switchgears and accessories as required a) 100 A, 30KA, FPMCCB - 1 No (in comer) & b) 63 amp , 30KA ,FP MCCB - 2 Nos (out comer) and 3 HP,3 phase sewage submersible pump DOL starter-3 Nos. c) Volt meter (0-500V) 96 Sq.mm with selector switch – 1 Setd) Amp-meter (0-100A) 96Sq.mm with selector switch & 100/5 Amp ratio CT's – 1 Sete) Indication Lamp (RYB) with control MCB fitting- 1 set.f) 20/32 amp DP MCB,’C’ Series 10 KA, (out going circuit)- 9 Nos.g) 6 amp SP MCB – 1 No.h) Power contactor, 3 pole, 110 Amp. -1 No. i) Astronomical Timer switch – 1 No.j) Auto/Manual toggle switch – 1 No.k) 200 amp, 4 strip aluminium busbar – 1 Setl) Danger Notice plate – 1 No.m) 6 Pin 15 A Switch / Socket outlet - 1 Set n) Lighting inside the feeder pillar Note: Foundation shall be made as per site requirement for which nothing extra shall be paid.
8LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 °C to 50 °C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI ≥70, under voltage and over voltage protection, EMI-EMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation ColourMatching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test reportand all testing required for LED fixtures as per BIS shall besubmitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).a)100 Watt
9b)90 watt
10c) 72 watt
11Supplying & fixing of hot dip Galvanized minimum 1000 mm long Bracket (to be installed at 6/7 mtr height) made out of suitable sized round pipe B-Class on octagonal pipe (3.60 mm Thick), 48 mm outer dia with 300 mm long galvanized overhang with tightening bolts etc. as reqd. Tilt angle shall be around 10 degree.a) Single arm bracket
12b) Double arm bracket
13Supplying & fixing of hot dip Galvanized minimum 500 mm long bracket (to be installed at 4 mtr height) made out of suitable sized round pipe B-Class on octagonal pipe (3.60 mm Thick), 48 mm outer dia with 300 mm long galvanized overhang with tightening bolts etc. as reqd. Tilt angle shall be around 10 degree.a) Single arm bracket
14b) Double arm bracket
15Supplying and fixing of single overhung galvanized steel arm bracket, minimum 1000 mm long, fabricated from 48 mm diameter GI pipe, comprising 300 mm projection for mounting the street light fitting and 700 mm portion fixed to the wall. The bracket shall be securely fixed with suitable clamps, nuts, bolts, and all necessary accessories complete, as required and as approved by the Engineer-in-Charge.
16LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt) Supplying, installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -5 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirementdeg, suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). a) 100 watt
17b) 150 watt
18C) 200 watt
19d) 250 watt
20Supplying and drawing 3 x 1.5 sq mm three core , flexible,round copper unarmoured, PVC sheathed cable connection etc as required.
21Supplying of following size of XLPE insulated aluminium Conductor having stranded wire armourd power cable of 1.1 KV grade i/c making, connection testing etc. as reqd.a) 2C x 10 sq.mm
22b) 4C x 10 sq.mm
23c) 4C x 35 sq.mm
24d) 2C x 16 sq.mm
25Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. a) Upto 35 sq.mm
26Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench as required but excluding sand cushioning, protective covering.a) Upto 35 sq.mm
27Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.a) Upto 35 sq. mm
28Laying and fixingof one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.a) Upto 35 sq. mm (clampped with 1 mm thick Saddle
29Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
30Supply, boring and laying of HDPE DWC pipes (ISI) marked of the 90 mm dia size confirming to IS:14930 part-II by trench less technology with no dig. method by making bore hole in horizontal direction across the road with boring equipment i/c jointing, cleaning, rodding of pipe providing suitable covers on mouth of pipes, excavation of pits of required size & depth etc. complete as required.
31Earthing with G.I earth pipe 4.5 mtr. long X 40 mm dia i/c accessories and providing masonry enclosure with cover plate, having locking arrangement and watering pipe etc. with charcoal or coke & Salt as reqd.
32Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nutbolt & spring washer spaced at 50mm)
33Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
34Supplying and fixing of 25 mm dia medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
35Providing and fixing of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel,making connections,Ics=100% Icu and operational voltage 690 V etc as required. 100 A 30 KA, FPMCCB
36Repairing,servicing assembling,testting and commissioning of 3 HP 3 phase sewage submersible pump i/c replacement of damaged/burnt parts such as bearings, oil seal, mechanical seal, gasket, cable joint kit, nuts & bolts, and rewinding of motor complete as required. Note:-Warranty for repaired work,Rewinding of motor and replaced parts shall be provided for a period of _12_ months from the date of successful commissioning.
37Repairing and servicing of 12.5 HP blower coupled with motor and pump including dismantling ,fault checking,motor rewinding/repairing,bearing replacement,Mechanical seal replacement,impeller cleaning,shaft alignment,pump servicing,assemle,installation and labour charges etc complete as required.Note:-Warranty for repaired work,Rewinding of motor and replaced parts etc shall be provided for a period of 12 months from the date of successful commissioning.
38Repairing and servicing of agitator i/c fault checking,bearing replacement,shaft alignment,blade replacement,seal replacement,motor checking and rewinding,installing,testing,commissioning and labour charges etc complete as required.
39Repairing ,servicing of existing dozing pump after checking and replacement/repairing of all damaged parts and make its functional ,installation,testing,commissioning and labour charges etc complete as required.
40Supplying & Fixing of following capacity/rating starter suitable for 3Phase, 415 Volts, 50Hz AC supply to operate the existing mono block open well submersible pump sets, testing etc as required(a) DOL Starter suitable for 5HP to 7.5HP motor MKI (LT/LK) Relay range - 9Amp to 14 Amp.
41Supplying, Installation, Testing & Commissioning of open well type dewatering sewage mono submersible pump set along with submersible motor for operation on 3 Phase, 415 Volts 50Hz AC supply in the existing water body etc. Complete as required suitable for following duties:- (i) Head Range - 12 Mtr. - 26 Mtr. (ii) Discharge Range - 560 LPM - 70 LPM & RPM-3000 (iii) Liquid - Sewage treated water having solid handling capacity-10.5 mm (iv) Capacity - 3HP (2.25 KW) (Minimum)
42PART - 'B' Comprehensive maintenance of all items for above mentioned BOQ.Comprehensive annual maintenance of all the E & M installations including pumps, panels, cables, street lighting, flood lighting, agitator, starters, timer, all panel items and its accessories including routine inspection, preventive maintenance, replacement of defective LED drivers, SPDs, , internal wiring, connectors, terminal blocks, minor cable repairs, tightening of electrical connections, cleaning of luminaires, testing of earthing, maintenance of feeder pillars/control panels, emergency breakdown repairs, transportation, tools and tackles, consumables, etc complete forNote:-The contractor shall be fully responsible for the watch and ward of all electrical and mechanical (E&M) installations covered under the contract during the entire period of comprehensive maintenance. The scope of work shall include the repair, replacement, and maintenance of all E&M installations, equipment, components, and their accessories as required to keep the system in proper working condition.No extra payment shall be made on account of watch and ward, repair, replacement of E&M installations, accessories, consumables, labor, tools and tackles, transportation, or any other incidental expenses. The quoted contract rate shall be deemed to include all such costs.
431st year DLP period
442nd year after DLP Period.
453rd year after DLP Period.
464th year after DLP Period. Total in Figures 18133216.76 18133216.76 INR One Crore Eighty One Lakh Thirty Three Thousand Two Hundred & Sixteen and Paise Seventy Six Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 INR Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56939269
AUTHORITY Local Bodies
TENDER VALUE 1.81 Crore
LAST DATE 18-08-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for Conservation Of Water Body Under North Zone. Sh:- Supply Installation Testing and Commissioning of Poles And Its Accessories Alongwith Repairing Of E/M Installation At Water Bodies Situated At Different Location Under North Zone.
Basic Detail
Tender No 23/EE/ELD-8/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 10 Aug 2026
Submission Date 18 Aug 2026
Open Date 19 Aug 2026
Finance
Tender Value 1.81 Crore
Tender Fee Ref. Documents
EMD 3.62 Lakhs
Exemption Not Available
Document List
134d0320-4467-4d1a-bd88-2017075e9d83.html
BOQ_968327.xls
TenderDoc23.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 18, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 2 days
Aug 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

134d0320-4467-4d1a-bd88-2017075e9d83.html

xls

BOQ_968327.xls

pdf

TenderDoc23.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders