Tender For Construction Of High-Rise Building Near Arumbakkam Metro Station Consisting Of Basement And Stilt Floor (4 -Tier Mechanical Car Parking System) Plus 7 Floors Of Commercial Space, Including Structural, Architectural, Mep, Signages, Hvac, Li
Tender Overview
Project Description
Tender for Construction Of High-Rise Building Near Arumbakkam Metro Station Consisting Of Basement And Stilt Floor (4 -Tier Mechanical Car Parking System) Plus 7 Floors Of Commercial Space, Including Structural, Architectural, Mep, Signages, Hvac, Lifts Facade Works And All Associated Works.
BOQ
| Sl. No. | Item Description |
| 1 | NOTE:1.Evaluation will be done by excluding Provisional sum and GST Amount 2.GST is to be quoted @ rate of 18% 3.The bid price shall be net of Input Tax credit availed by the bidder i.e., base price shall not have any GST component in it. In effect, the clause 171 of GST, that is, the Anti-Profiteering Rule shall be adhered to. A self-declaration from the bidder on clause 171, shall be attached with the invoice. The output GST paid by the bidder shall be reimbursed by CHENNAI METRO RAIL LIMITED on production of the documentry evidence |
| 2 | SUMMARY OF PRICE BID |
| 3 | 2.0 B- ARCHITECTURAL ITEMS: B1.PAVEMENT FOR FOOTPATH |
| 4 | B1.1.Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. B2.BLOCKWORK |
| 5 | B2.1. 200THK - Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). |
| 6 | B2.2.100THK - Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. |
| 7 | B2.3.Parapet Wall at Upper Terrace Floor- 230THK - Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 8 | B2.4.Compound Wall Construction: 230THK - Providing and fixing up to floor five level precast cement concrete solid block, including hoisting and setting in position with cement mortar 1:3 (1 cement : 3 coarse sand), cost of required centering, shuttering complete : 1:1½:3 (1 Cement: 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 9 | B2.5.Providing and applying 12mm thick plaster in cement mortar 1:4 (1 cement : 4 fine sand); to exposed surfaces of concrete and masonry works ,keeping the surface rough (with sponge) to receive finishing work or as required to receive specified architectural finish, to correct line, plumb and level to external faces of walls, including rounding off corners wherever required smooth rendering, including raking out joints, hacking concrete surfaces, preparing junctions of concrete / masonry by neat cleaning, pointing / grouting using non-shrink mortar and further grouting junctions by pressing square crush aggregate; preparing jambs, sills, grooves, pattas, wattas, rounding of corners, etc.including provision of corner beads to prevent accidental damage at all levels, heights, locations with all lifts and all leads, including scaffolding, cost of materials, labour, cleaning of surfaces, curing, etc. to complete as per specifications and as directed by the Engineer. |
| 10 | B2.6.Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. B3.PAINTING @ COMMON AREAS |
| 11 | B3.1.Interior Painting in Common Areas:Colour washing such as green, blue or buff to give an even shade : New work (two or more coats) with a base coat of white washing with lime |
| 12 | B3.2.Exterior Painting in Common Areas & Parapet at Terrace Floor: Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm sqm 223.60 B4.FLOORING |
| 13 | B4.1.Lift Lobby Area: Providing and laying gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.With granite stone of colour black, cherry/ruby red of area less than 0.50 sqm. |
| 14 | B4.2.Stair Case area: Lift Lobby Area: Providing and laying (including Thread,landing area & skirting) gang saw cut 30 mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape of approved shade, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20 mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer-in-Charge.With granite stone of colour black, cherry/ruby red of area less than 0.50 sqm. |
| 15 | B4.3.Staircase Riser: Providing and fixing machine cut, mirror polished 18 mm thick Granite stone for skirting, risers of steps of approved colour in required size, design and patterns, all complete as per the architectural drawings, over 12mm thick base Cement mortar (1:3) laid and jointed with neat cement slurry mixed with pigment to match the shade of garnite stone including lead and lift at all levels and for all heights and location complete as per specifications and drawings as approved by the engineer.With granite stone of colour black, cherry/ruby red of area less than 0.50 sqm.With granite stone of area less than 0.50 sqm. |
| 16 | B4.4.Electrical Room Floor: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm B5.WALL CLADDING |
| 17 | B5.1.Lift Wall Granite Cladding: Providing and fixing dry cladding upto 10 mtrs height with 18mm thick Gang saw cut polished granite stone of approved colour in required size, design and patterns, fixed to structural steel grame and or with the help of steel clamps/cramps, pins, etc., sealing the joints with approved weather sealant as approved drawing and direction of engineer. Rates to be inclusive of all cramps, clamps, pins, etc., B6.FALSE CEILING @ COMMON AREA(LOBBY) |
| 18 | B6.1.Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600 mm to formgrid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6 mm thick with precut hole on both 25 mm flange to pierce into 12x50 mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge. With 15 mm thick Tegular edged light weight calcium sliciate false ceiling tiles SS HANDRAILS at Staircase |
| 19 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). B8.DOORS @ COMMON AREAS |
| 20 | B8.1.Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet (Zinc coating not less than 120 gm/sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled with mineral wool Insulation having density minimum 96Kg/sqm. The frame will have a provision of G.I. anchor fastners 14 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80) suitable for fixing in the opening along with factory made template for SS ball bearing hinges of size 100x89x3 mm for fixing of fire rated glazed shutter. The frame shall be finished with an approved fire resistant primer or powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in- Charge. (Cost of SS ball bearing hinges is excluded). |
| 21 | B8.2.Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes Fire rating conforming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) duly filled mineral wool insulation having density minimum 96 kg/cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3 mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-Charge (panelling to be paid for seperately). B9.WINDOWS @ COMMON AREAS(STAIRCASE) |
| 22 | B9.1. Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) B10.ROLLING SHUTTERS |
| 23 | B10.1.Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. a)80x1.25 mm M.S. laths with 1.25 mm thick top cover total 3 rolling shuttes of size 1.3(w)x4.1(h) |
| 24 | B10.2.Extra for providing mechanical device chain and crank operation for operating rolling shutters.A, Exceeding 10.00 sqm and upto 16.80 sqm in the area B11.LIFT |
| 25 | B11.1.Design, Supply, Erection, Testing and commissioning of passenger lift with Stainless Steel finish Car enclosure to carry 13 passengers of 884kgs of machine roomless, synchronizing motor - Gearless VVVF controller in the existing lift well / shaft having minimum speed of 2 m/sec with a total travel of 30 (Approx) mtrs. Stilt plus 7 upper floors, servicing 7 stops and 7 landings on the same side with / without attendant operation. The car cabin wall shall be by the combination of MS base plate of 1.5mm thick over which skin plate of 0.6mm etched / scratch proof stainless steel is affixed and bonded to farm a over all wall thickness of 2.1mm and with all necessary safety features and in accordance with Lift Service particulars, General / Technical Specification, special condition etc. The design pattern shall be of combination of etched / scratch proof stainless steel and shall be as per Architect / Owner requirement and approval. B12.MECHANICAL CAR PARKING SYSTEM FOR 36 CARS |
| 26 | B12.1.Four Tire Mechanical ventilated car parking for 36 cars - Design, manufacture, supply, installation, testing and commissioning of a fully automated mechanical ventilated car parking system for 36 cars, including complete system engineering, structural supports, control systems, safety devices, power and drive mechanisms, electrical works, trial runs, training of personnel and obtaining statutory approvals, all complete as per Employer’s Requirements and approved drawings.The system shall include 3 years warranty from the date of commissioning.After expiry of the warranty period, the Contractor shall provide Comprehensive Operation & Maintenance including supply of all spares, consumables and materials for a period of 3 years at 4% of the basic project cost per annum. |
| 27 | 2.0 C- STRUCTURAL C1.SITE CLEARANCE: |
| 28 | C.1.1Site Clearance: Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil C2.SURVEYING: |
| 29 | C.2.1SURVEYING - Carrying out detailed topographical survey of the vacant land using Total Station / DGPS equipment, establishing survey control points with reference to permanent benchmarks, recording all existing ground features, levels and spot levels at regular grid intervals of 3 m × 3 m, preparation of contour plan, site plan and level sheets, including demarcation of plot boundary, grid setting-out, traversing, computation, plotting, and submission of survey drawings in soft and hard copies in approved scale and formats (AutoCAD & PDF). The work shall include all labour, instruments, calibration, data processing, transportation, setting out materials, and incidental works complete as directed by the Engineer-in-Charge, in accordance with relevant IS codes and Employer’s Requirements. C3. ITEMS: |
| 30 | C.3.1Providing confirmatory Geotechnical soil investigation works including mobilization of plant, machinery and manpower; setting out; drilling of two (2) nos. boreholes up to a depth of 40 metres each using rotary/percussion drilling methods through all types of soil/strata (including gravels, hard strata, weathered rock etc.); collection of disturbed and undisturbed soil samples at specified depths; conducting in-situ tests including SPT at 1.5 m intervals and at change of strata; core drilling and recovery in rock; preservation, labelling and transport of samples; laboratory testing including index and strength tests as required; preparation of bore logs; groundwater table observation; and submission of a detailed geotechnical investigation report including recommendations on allowable bearing capacity, settlement, pile capacity (if applicable), geotechnical design parameters and strata profiles, complete as per relevant IS codes and to the satisfaction of the Engineer-in-Charge.(Rate to include all labour, materials, equipment, transportation, testing, reporting and incidental works complete.) C4.Temporary Shoring: Sheet Piling/s\Secant pile/ Soldier pile |
| 31 | C.4.1.Temporary Shoring with 'Z' section MS sheet piles side by side in all kinds of soil mechanically or manually as per approved drawings with contractor's own arrangement complete in all respects and removal of sheet piles after completion of the work as directed by engineer in-charge (Note - Payment will be made as per actual driven lemgth of Pile) C5.RCC Piling Works: |
| 32 | C5.1.RCC Piling Works 750mm DIA Pile including Boring:Piles:- Providing and installing cast-in-situ vertical bored piles of required depth as per approved GFC drawing with M30 grade of reinforced cement concrete using Portland slag cement including all operations such as mobilization, installation and shifting of piling rig etc., in all soil strata, rock grade V, IV & III, road, footpath including boulders and kankar (other than in rock grade GI and GII). The item includes disposal of earth, muck, slush released from piles, top cut portion of pile at contractor's dumping ground with all leads and lifts .Disposal / utilization of the excavated soil as per contractors own arrangements / choice including loading , transportation, unloading to any lead with all necessary safety / environmental compliances measures as defined in the relevant section of the contract document. The rate shall include all operations required for installation of pile such as installation of rig, shifting of hydraulic rig, construction of approach temporary road / bridge for pilling rig etc.The cost shall also include the cost of empty boring with MS temporary liner as per site requirement. The Cost shall also include cutting/chipping of pile up to cut off level or up to good concrete and built up of pile up to required level( as per drawing). Rate shall include cost of using required dosage of admixture in concrete for obtaining required workability as per approval of Engineer in Charge. Cost for temporary casing shall be included in the rate.Piling / Drilling shall be done by use of hydraulic rotary rigs using temporary casing till required depth(Min 4.5 Mtr ). Bentonite/Polymer slurry to be used as directed by the Engineer-in-charge. The item shall also include the cost of bentonite/Polymer to be used for stabilisation of bore. Bentonite/Polymer shall be allowed with the specific approval of Engineer based on the soil strata. Socketing shall be as per specification and the decision of Engineer shall be final . Reinforcement works shall be paid seperatelyNote: Pile measurement shall be from cut-off level to founding level as shown in the drawing |
| 33 | C5.2.BORED PILE FOUNDATION 450mm DIA: Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 450 mm dia piles C6.NDT test pile |
| 34 | C6.1.Conducting Cross Hole Sonic Logging test and report submission - for 25% of executed Piles or as per relevant codes |
| 35 | C6.2.Pile integrity test for 100% of executed piles |
| 36 | C6.3.Initial Pile Load Test -VERTICAL:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge.Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing. Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-charge.Single pile above 50 tonne and upto 100 tonne Safe capacity: Initial test (Test Load 2.5 times the Safe capacity) |
| 37 | C6.4.Initial Pile Load Test - LATERAL:Lateral load testing of single pile in accordance with IS : Code of practice IS: 2911 (Part IV) for determining safe allowable lateral load on pile : Above 50 tonne and upto 100 tonne capacity pile C7.EARTH WORK: |
| 38 | C7.1.Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. C8.Excavation |
| 39 | C8.1.Dewatering by pumping including hire and running of pumps, labour, fuel, power, pipes, hoses and accessories, maintaining dry condition during execution of basement works. C9.WATER PROOFING WORKS: Substucture works Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. Thecrystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. For vertical surface two coats @ 0.70 kg per sqm per coat |
| 40 | C9.1.Exterior Surface of Retaining wall + Interior Surface of Sump For horizontal surface one coat @1.10 kg per sqm. |
| 41 | C9.2.Base slab of Sump |
| 42 | C9.3.Water Proofing at Upper Terrace: Providing and laying integral cement-based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a. Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with + treatment. b. Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. c. After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge. d. Finishing the surface with 20 mm thick jointless cement mortar of mix1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS: 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.d. The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. \\"all above operations to be done in order and direct and specified by the Engineer in charge.\\" (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”:with average thickness of 120 mm and minimum thickness of khurra at 65mm C10.PLAIN CEMENT CONCRETE: |
| 43 | C10.1.Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. All works upto stilt level. Concrete of M15 grade with minimum cement content of 240 kg /cum.Storm water drain, basement raft & compound wall plinth beam. C11.REINFORCED CEMENT CONCRETE WORKS- SUB STRUCTURE M30 Grade: |
| 44 | C11.1.Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate erived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Concrete of M30 grade with minimum cement content of 350 kg /cum.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement for Pile cap, raft slab,sump,roof beam, column, shear wall, retaining wall,lift pit,staircase, basement roof slab, basement roof beam, compound wall beam and column. C12.REINFORCED CONCRETE WORKS: SUPER STRUCTURE M30: |
| 45 | C12.1.Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate erived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Concrete of M30 grade with minimum cement content of 350 kg /cum.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto upper Terrace level: Concrete of M30 grade with minimum cement content of 350 kg /cum for PT Beam , RC Beam, column, floor, shear wall, staircase,PT slab, RC slab, and overhead tank C13.STORM WATER DRAIN - M25: |
| 46 | C13.1.Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.:All works upto plinth level: Concrete of M25 grade with minimum cement content of 330 kg /cum for Base slab, RC wall & RC cover slab C14.Steel reinforcement for R.C.C. Thermo -Mechanically treated bars of grade FE-500D or more. |
| 47 | C14.1.Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete Structure.-Thermo -Mechanically treated bars of grade FE-500D or more for pile, pile cap, Retaining wall, raft, UG Sump, OHT tank & slab, storm water drain, beam , column, PTslab & PT Beam, Compound wall-column,beam, C15.PT TENDONS Design and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, supplying, laying of HT strands sheathing (Gl corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing liveend anchorages, including supply of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering, concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the PMC / Employer. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights(all Floors) including all leads, (INCLUDING LIFTING CHARGES) etc., all complete and as approved and as directed by the Engineer-in-charge .Supply & execution of post tensioning work shall be carried out by approved specialized agency, with their own design, equipment, accessories & skilled manpower for satisfactory completion of work as per approved drawings. The contractor shall have minimum 5 years experienced technical staff for proper monitoring, ensuring & certifying the correctness of entire prestressing operations. Prestressing work shall be duly tabulated and report shall be submitted. Item also to include the required scaffolding etc. including marking the PT strand path locations for easy identification etc. all complete to the entire satisfaction of PMC/Employer. |
| 48 | C15.1.PT SLAB Tendons |
| 49 | C15.2.PT BEAM Tendons- (Three Types) C16.CENTRING & SHUTTERING: |
| 50 | C16.1.Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc., Centering for reataining wall, basement raft slab, sump,beam,column,shear wall,roof slab,OHT,Compound wall C17.Earthwork backfill |
| 51 | C17.1.Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift.Earthwork backfill C18.SUNKEN FILLING IN TOLIETS IN COMMON AREAS |
| 52 | C18.1.Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) C19.MS GATE AT MAIN ENTRANCE |
| 53 | C19.1.Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete Hot finished seamless type tubes C20.FLOORING |
| 54 | C20.1.Screed Concrete: 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 55 | 2.0 D- PLUMBING |
| 56 | D1.SANITARY FIXTURES & FITTINGS |
| 57 | D1.1. Supply ,Fixing, testing and commissioning of white vitreous china Wall Mounted Type European Water Closet including C.P. bolts, nuts, C.I. chair ( painted with two coats of enamel paint over a coat of primer ) or other hanging arrangements, bakelite / poly propylene seat & cover with C.P. hinges & rubber buffers, complete with all accessories. Including cutting & making good the walls & floors wherever required. Make: Parryware |
| 58 | D1.2. Supply ,Fixing, testing and commissioning of Concealed Cistern (3/6 LPF) with Push plate suiable for wall mounted EWC. The works shall include cutting and making good the walls & floors complete as required. Make: Parryware |
| 59 | D1.3. Supply ,Fixing and testing of 15 mm CP brass Health Faucet of approved make with necessary CP flexible hose 1000 mm long nozzle, CP wall flange etc., complete. Make: Parryware |
| 60 | D1.4. Supply ,Fixing, testing and commissioning of 15 mm dia C.P. brass 2 Way Cock With C.P. Wall Flange of approved quality and making good as required. Make: Parryware |
| 61 | D1.5. Supply, Fixing, testing and commissioning of white coloured vitreous china Regular Oval / Rectangular Wash Basin with brackets / G.I. rag bolts and nuts painted. The work shall include cutting / chasing and making good the walls and floors. Make: Parryware, i)Manualy operated pillar cock for wash basin, ii)32mm dia CP brass waste coupling ,iii)15mm dia CP brass angle valve ,iv)15mm dia flexible cold connection pipe |
| 62 | D1.6. Supply & Fixing, testing and commissioning of Urinal basin with automatic flushing systems opearating AC power supply for urinal to ensure pre-flush & flushing only immediately after use, comprising of all plumbing, electronic and electrical items. CP brass flush pipe with CP brass elbow, CP brass spreader, CP wall flange, infrared photo cells, eyes electrically operated solenoid valve, step down transformer / equipment and any other item required to provide satisfactory functioning. Including necessary wall cutting / chasing and making good, as required. Make: Parryware |
| 63 | D1.7. Supply, checking, storing & fixing 15 mm. dia exposed Concealed stop cock with 1/2\\" outlet with wall flange and all accessories. (For Water Inlet control) |
| 64 | D1.8. Fixing of C.P brass Toilet paper holder with PVC rawl plug & C.P. brass screw complete as required. |
| 65 | D1.9. Fixing of C.P. brass Twin coat hook with PVC rawl plug & C.P. brass screw complete as required. |
| 66 | D1.10. Fixing of Soap Dish Holder with necessary fixing with SS screws and clamps etc., complete. |
| 67 | D1.11. Fixing of of Hand dryer of approved make or equivalent with necessary accessories etc all complete as directed by the Engineer-in-charge. |
| 68 | D2. SOIL WASTE AND RAIN WATER PIPES |
| 69 | Supplying, fixing, testing and commissioning of PVC Soil, waste and ventilating pipes (SWR) conforming to IS:13592 /1990 -Type B with rubber ring (conforming to IS : 5382) joints inclusive of all necessary specials like bends, tee, offsets, door bends, junctions, cowls etc., laid under floor /fixed on walls and in pipe shaft with proper pipe support like brackets, hangers, MS grip bolts etc., complete. The support shall be painted with two coats of enamel paint. |
| 70 | INTERNAL |
| 71 | D2.1. 40 mm for Wash basin drains |
| 72 | D2.2. 50 mm for Urinal drains |
| 73 | D2.3. 75 mm Waste pipe |
| 74 | D2.4. 110 mm soil pipe |
| 75 | D2.5. 110 mm Rain pipe |
| 76 | VERTICAL RISER |
| 77 | D2.6. 110 mm (Rain water - vertical) |
| 78 | D2.7. 110 mm (soil - vertical) |
| 79 | D2.8. 75 mm (waste - vertical) |
| 80 | D2.9. Supplying, installing, testing and commissioning of Special type bathroom grating. outlet fixed on a bed of cement concrete with standard size stainless steel type grating with cover (Heavy duty type) etc., complete. The cost shall include. |
| 81 | D2.10. Supplying, installing, testing and commissioning of PVC Floor trap with 110mm dia inlet and 75mm dia. outlet fixed on a bed of cement concrete with 150 x 150mm stainless steel type grating with threaded cover (Heavy duty type) etc., complete. The cost shall include Cockroach Traps., |
| 82 | D2.11. Providing and fixing Heavy class S.S. grating with cockroach/mosquito proof S.S. strainer of Chilly or equivalent make, as approved, (inch cockroach trap) including setting in floor with cement mortor to match with floor finish as per architect requirements. |
| 83 | Fixing of the C.I khurra incl 100x300mm Bell Mouth Roof Drain within the water proofing fill above roof and taking out rain water outlet by fixing an elbow to the khurra outlet and making connection to the rain water down coming pipe, painting the grating with one coat of primer and two coats of black enamel paint. |
| 84 | D2.12. a) 110mm |
| 85 | D3.INTERNAL WATER SUPPLY SYSTEM |
| 86 | Supplying, installing, testing & commissioning Chlorinated Polyvinyl Chloride (CPVC) pipes, SDR 11 as per IS 15778: 2007 & fittings as per ASTM D2846 / D2846M - 14, both of approved make having thermal stability for hot & cold water supply make with Solvent cement joint, including all CPVC plain & brass threaded fittings such as bends, elbows, tees, sockets, unions, plugs etc., including fixing the pipe., including necessary drilling holes, chasing walls and making the same good in as directed by the Engineer in-charge. |
| 87 | Cold Water - Internal |
| 88 | D3.1.a) 20 mm dia |
| 89 | D3.2.b) 25 mm dia |
| 90 | Flush Water - Internal |
| 91 | D3.3.a) 20 mm dia |
| 92 | D3.4.b) 25 mm dia |
| 93 | D3.5.c) 32 mm dia |
| 94 | DWS Terrace Ring Main (UPVC) |
| 95 | D3.6.a) 40 mm dia OHT Outlet |
| 96 | D3.7.b) 50 mm dia OHT Inlet |
| 97 | FWS Terrace Ring Main (UPVC) |
| 98 | D3.8. a) 50 mm dia OHT Outlet |
| 99 | D3.9. b) 65 mm dia OHT Inlet |
| 100 | DWS Riser (UPVC) |
| 101 | D3.10. a) 25 mm dia OHT Outlet |
| 102 | D3.11.b) 32 mm dia OHT Outlet |
| 103 | D3.12. c) 40 mm dia OHT Outlet |
| 104 | D3.13. d) 50 mm dia OHT Inlet |
| 105 | FWS Riser (UPVC) |
| 106 | D3.14. a) 32 mm dia OHT Outlet |
| 107 | D3.15. b) 40 mm dia OHT Outlet |
| 108 | D3.16. c) 50 mm dia OHT Outlet |
| 109 | D3.17. d) 65 mm dia OHT Inlet |
| 110 | Supplying, installing and testing and commissioning of approved make PN 16 class GM ball valves with necessary unions etc., complete in all respect. |
| 111 | D3.18. a) 32 mm dia (Screwed ends) |
| 112 | D3.19. b) 40 mm dia (Screwed ends) |
| 113 | D3.20. c) 50 mm dia (Screwed ends) |
| 114 | Supplying, installing, testing and commissioning PN 16 CI butterfly valves with standard lever conforming to BS 5155 with necessary connecting 'fittings like flanges, nuts and bolts etc., complete in all respect. |
| 115 | D3.21. a) 65mm dia |
| 116 | D3.22. b) 100mm dia |
| 117 | D3.23.Providing and fixing GM Air release valve inch 25 to 20 reducer, double acting, of approved make, having 2 chambers with ebonite ball, small and large orifices with isolating stop screw down valve, GM seats, high tensile brass spindle with cap, conforming to standard water works pattern. Flanges as per IS : 15381, flat faced and drilled, complete of the following nominal bore (NB) size: |
| 118 | D4.INTERNAL SUMP AND OHT PUDDLE FLANGES |
| 119 | D4.1 Supplying, fixing and installation of inlet, outlet, vent and over flow pipe puddle flanges with Heavy duty D.I frame and cover for under ground water tank complete as shown on the drawings with SS 304 10mm thick puddle flange conforming to table F with thickness of wall ratio 1:2, accessories comprising of the following |
| 120 | D4.1.1.Fire UG Tank - 1 ( 1 Nos ) |
| 121 | Approx. Sise = 11.2m (Length), 4.70m (Width) & 1.50m (Depth, Including 0.300m free board) |
| 122 | D4.1.1.1a) MS manhole frame & cover (16G Sheet) with locking facility. |
| 123 | D4.1.1.1b) Inlet puddle flanges |
| 124 | 100 mm Dia, Tanker Inlet |
| 125 | 50 mm Dia, Borewell Inlet |
| 126 | 32 mm Dia, Metro Inlet |
| 127 | D4.1.1.C)outlet puddle flanges |
| 128 | 80 mm Dia, OHT Inlet |
| 129 | D4.1.1. 1d) vent pipe 100mm dia. |
| 130 | D4.1.1.1e) Overflow Pipes 100mm dia. |
| 131 | D4.1.1.1f) Sleeves for level controllers (25 mm dia.) |
| 132 | D4.1.1.1g) 65mm Dia, Spare |
| 133 | D4.1.1.1h) 100mm Dia, Fire to Fire Interconnect |
| 134 | D4.1.1..1i) PVC Rungs |
| 135 | D4.2.Supplying, fixing and installation of inlet, outlet, vent and over flow pipe puddle flanges with Heavy duty D.I frame and cover for under ground water tank complete as shown on the drawings with SS 304 10mm thick puddle flange conforming to table F with thickness of wall ratio 1:2, accessories comprising of the following |
| 136 | D4.2.1..Fire UG Tank - 2 ( 1 Nos ) |
| 137 | Approx. Sise = 11.2m (Length), 4.70m (Width) & 1.50m (Depth, Including 0.300m free board) |
| 138 | D4.2.1.1a) MS manhole frame & cover (16G Sheet) with locking facility. |
| 139 | D4.2.1.1b)outlet puddle flanges |
| 140 | 80 mm Dia, OHT Inlet |
| 141 | D4.2.1.1c) vent pipe 100mm dia. |
| 142 | D4.2.1. 1d) Overflow Pipes 100mm dia. |
| 143 | D4.2.1.1e) Sleeves for level controllers (25 mm dia.) |
| 144 | D4.2.1. 1f) 65mm Dia, Spare |
| 145 | D4.2.1. 1g) 100mm Dia, Fire to DWS Interconnect |
| 146 | D4.2.1. 1h) PVC Rungs |
| 147 | D3.Supplying, fixing and installation of inlet, outlet, vent and over flow pipe puddle flanges with Heavy duty D.I frame and cover for under ground water tank complete as shown on the drawings with SS 304 10mm thick puddle flange conforming to table F with thickness of wall ratio 1:2, accessories comprising of the following |
| 148 | D3.1..DWS UG Tank - 2 ( 1 Nos ) |
| 149 | Approx. Sise = 2.20m (Length), 4.70m (Width) & 1.50m (Depth, Including 0.300m free board) |
| 150 | D3.1. 1a) MS manhole frame & cover (16G Sheet) with locking facility. |
| 151 | D3.1.1b)outlet puddle flanges |
| 152 | 65mm Dia, OHT Inlet |
| 153 | D3.1. 1c) vent pipe 100mm dia. |
| 154 | D3.1. 1d) Overflow Pipes 100mm dia. |
| 155 | D3.1. 1e) Sleeves for level controllers (25 mm dia.) |
| 156 | D3.1. 1f) 65mm Dia, Spare |
| 157 | D3.1. 1g) PVC Rungs |
| 158 | D4.Supplying, fixing and installation of inlet, outlet, vent and over flow pipe puddle flanges with Heavy Duty D.I frame for Overhead water tank, complete as shown on the drawings with SS 304 10mm thick puddle flange conforming to table with thickness of wall ratio 1:2, accessories comprising of the following. |
| 159 | D4.1.Fire Over Head Tank - 1Nos |
| 160 | Approx. Size = 5.16m (Length), 4.40 (Width) & 0.9m (Depth, Including 0.300m free board) |
| 161 | D4.1. 1a) MS manhole frame & cover (16G Sheet) with locking facility. |
| 162 | D4.1. 1b) Inlet puddle flanges |
| 163 | 50 mm Dia, Inlet |
| 164 | D4.1. 1c)outlet puddle flanges |
| 165 | 100 mm Dia, OHT Outlet |
| 166 | D4.1. 1d) vent pipe (100mm dia.) with mosquito proof mesh |
| 167 | D4.1. 1e) Overflow Pipe 100 mm Dia |
| 168 | D4.1. 1f) 65mm Dia, Spare |
| 169 | D4.1. 1g) Drain pipe puddle flange - 50 mm dia |
| 170 | D4.1. 1h) Sleeves for level controllers (25 mm dia.) |
| 171 | D4.1. 1i) 100mm Dia, Fire to DWS Interconnect |
| 172 | D4.1. 1j) PVC Rungs |
| 173 | D5.Supplying, fixing and installation of inlet, outlet, vent and over flow pipe puddle flanges with Heavy Duty D.I frame for Overhead water tank, complete as shown on the drawings with SS 304 10mm thick puddle flange conforming to table with thickness of wall ratio 1:2, accessories comprising of the following. |
| 174 | D5.1.DWS Over Head Tank - 1Nos |
| 175 | Approx. Size = 1.10m (Length), 4.40m (Width) & 0.90m (Depth, Including 0.300m free board) |
| 176 | D5.1.1a) MS manhole frame & cover (16G Sheet) with locking facility. |
| 177 | Booster outlet puddle flanges |
| 178 | 40 mm Dia, OHT Outlet |
| 179 | D5.1.1c)outlet puddle flanges |
| 180 | 40 mm Dia, OHT Outlet |
| 181 | D5.1. 1d) vent pipe (100mm dia.) with mosquito proof mesh |
| 182 | D5.1. 1e) Overflow Pipe 100 mm Dia |
| 183 | D5.1. 1f) Drain pipe puddle flange - 50 mm dia |
| 184 | D5.1. 1g) Sleeves for level controllers (25 mm dia.) |
| 185 | D5.1. 1h) PVC Rungs |
| 186 | D6.Supplying, fixing and installation of inlet, outlet, vent and over flow pipe puddle flanges with Heavy Duty D.I frame for Overhead water tank, complete as shown on the drawings with SS 304 10mm thick puddle flange conforming to table with thickness of wall ratio 1:2, accessories comprising of the following. |
| 187 | D6.1..Flush Over Head Tank - 1Nos |
| 188 | Approx. Size = 2.24m (Length), 2.25 (Width) & 0.9m (Depth, Including 0.300m free board) |
| 189 | D6.1. 1a) MS manhole frame & cover (16G Sheet) with locking facility. |
| 190 | D6.1. 1b) Inlet puddle flanges |
| 191 | 65 mm Dia, Inlet |
| 192 | D6.1. 1c)outlet puddle flanges |
| 193 | 50 mm Dia, OHT Outlet |
| 194 | D6.1. 1d) vent pipe (100mm dia.) with mosquito proof mesh |
| 195 | D6.1. 1e) Overflow Pipe 100 mm Dia |
| 196 | D6.1. 1f) Drain pipe puddle flange - 50 mm dia |
| 197 | D6.1. 1g) Sleeves for level controllers (25 mm dia.) |
| 198 | D6.1. 1h) PVC Rungs |
| 199 | D7.EXTERNAL SEWERAGE SYSTEM |
| 200 | D7.1.Providing and fixing testing and commissioning of PVC pipe for Risers to IS:13592 of SWR quality Type B, for stilt floor buried lines, external buried including all fittings like tees, elbows, bends, collars, coupling, brackets, clamps, fasteners, , etc jointing with rubber ring / solvent cement followed by application of leak proof adhesive like FRP paste complete. The pipes shall be fixed properly aligned vertical with suitable Galvanised MS pipe clamps. Work to include making necessary holes in the masonary walls etc.. and making good the damaged portions with mortar filling with 1:4 mix. Before handing over, leak test shall be carried out and any defects found shall be rectified. |
| 201 | D7.1.1.Drainage Network |
| 202 | 50mm dia |
| 203 | 75mm dia |
| 204 | 80mm dia |
| 205 | 110mm dia |
| 206 | 160mm dia |
| 207 | D7.1.2. Excavation in all types of soil for laying pipes upto 160mm dia. Including forming bottom surface to required level, refilling selected excavated earth around the pipe in layers as per Specifications, watering, consolidating and disposing off the surplus earth to the approved dumping site by local Authorities etc., complete. Depth upto 1.2 M. |
| 208 | D7.1.3.Supplying, fixing and testing of PVC Fabricated Gully Trap with top square bodies 300mm x 300mm, set in PCC 1:3:6 bed with RCC chamber and top cover shall be as indicated in the drawings, internal and external plastering 12mm thick in CM1:6 with water proofing compound including, excavating, refilling and ramming ,D.I (heavy duty type 40T) manhole cover with frames Heavy duty etc., complete |
| 209 | D7.1.3.Supplying, fixing and testing of PVC Fabricated Gully Trap with top square bodies 300mm x 300mm, set in PCC 1:3:6 bed with RCC chamber and top cover shall be as indicated in the drawings, internal and external plastering 12mm thick in CM1:6 with water proofing compound including, excavating, refilling and ramming ,D.I (heavy duty type 40T) manhole cover with frames Heavy duty etc., complete |
| 210 | 2.0 E-PUMPS & PUMPS ACCESSORIES |
| 211 | E1.PUMPS & PUMPS ACCESSORIES |
| 212 | Supply ,Testing & Commissioning , of a pre-engineered, factory fabricated, assembled & tested, fully integrated, highly efficient Verical pump of SS-304 body,Impeller & Shaft mounted on a MSEP skid complete with all accessories as per manufacturer specifications. Accessories like ball valves, butterfly valves, non return valves, pressure gauges and dead end flanges on suction and discharge headers complete as required with all accessories integrated variable frequency drive for each pump, with inbuilt controller.Multible VFD and controller to control the system requirement,.The pump logic controller shall have function such as Pressure control, Multi master function, Min time between start stop, Dry running, Low flow stop functoin, Fault primary sensor, Soft pressure built up Specific energy consumption,automatic pump alternations for run time equalization, Programmable number of starts/stops per hour to prevent pump hunting, Redundant primary sensor for pressure monitoring, soft pressure built-up. The system should be compatible with BMS through MODBUS. Vertical in line multistage pump Motor enclosure shall be IP 55, motor insulation class shall be of Class F ,motor to be of efficiency IE3 and Precharged diaphram pressure vessel with food grade membrane, charging connection, connected to outlet header with necessary flanges, gaskets, isolating valves, nuts/bolts, GI suction and Delivery manifold & float switch etc complete. E1.1.Pump capacity: 0.55 LPS/each, E1.1.1.Pump configuration: 3Nos (2W+1S), Head: 49MWC,RPM: 2900, Purpose: Domestic water Distribution, Location: WTP Pump room. |
| 213 | E1.2.Pump capacity: 3.35 LPS/each, E1.2.1.Pump configuration: 2Nos (1W+1S), Head: 40 MWC, RPM: 2900, Purpose: Flushing water Distribution, Location: STP Pump room |
| 214 | E1.3.Supply, installation in position, testing and commissioning of electrically driven factory-assembled and tested non clog open impeller Dewatering pumps of approved make or equivalent, capable of discharging as mentioned below including fasteners, expansion bolts, nuts, with necessary accessories etc. all complete as directed by Engineer in Charge. Motor to be Hermetically sealed, capacitor-start type, with built-in overload protection; dry run protection; three-conductor waterproof power cable of length required, and with grounding plug and cable-sealing assembly for connection at pump.f) Motor enclosure shall be IP 68 in accordance with IS/IEC 60034 : Part 5 : 2000 (Reaffirmed 2007) and motor insulation class shall be of Class F in accordance with IS 1271:1985 (Reaffirmed 2007)/IEC 60085:2004.Pump motors shall be of Efficiency class IE 3 & operating range within 5 % of BEP. MODbus/BACnet port connectivity for interface to building automation system for On, Off, Run & alarm status of each pump. (1 set =1W+1S), E1.3.1.Pump capacity: 4.5 LPS/each, Head : 55-60mwc, Solid Handling : 50mm, MOC : CI Body , Impeller & SS Shaft, Location: Raw sewage Transfer pump incase of STP failure. |
| 215 | E1.4.Supply, installation in position, testing and commissioning of Horizontal centrifugal pump, Each pump shall have TEFC 2900 RPM three phase electric motor. The pump shall have CI body, bronze impelleer. Pumps shall be provided with mechanical seal. The pump shall be suitable for auto / manual operation. E1.4.1.Pump capacity: 4.5 LPS/each,Pump configuration:2Nos (1W+1S), Head: 55-60MWC, RPM: 2900, Purpose: Excess treated water transfer pump, Location: STP Pump room |
| 216 | E1.5.Supply, installation, testing and commissioning of continuous duty submersible centrifugal non-clogging drainage pumps complete with 3 phase motor with all necessary protection and mechanical seal ,with internal cooling jacket etc. The submersible pump shall be of bottom suction and top discharge type.complete with all ancillaries including float type level controllers, electrical control panels fabricatd from 14 gauge CRCA sheet(Powder coated paint finish) volt meter ammeter with selector switch, TPMCB, 5 VA CL : CTs, phase indicating lamps protected by 2 amp SP MCB, DOL starter, necessary wiring, cable alleys, earthing, interlocking, starter with Automatic float type level controller, provision of high level alarm, sequence timer, MODbus/BACnet port connectivity for interface to building automation system for On, Off, Run & alarm status of each pump. Flow rate : 4.5 LPS/each, E1.5.1.Pump configuration:2nos (1W+1S), Head : 12-15MWC, Solid Handling : 10-12mm, MOC : CI Body & Impeller and SS Shaft, Maximum depth of sump:4m, Location: WTP & STP PUMP ROOM. |
| 217 | E1.6.Supply, installation, testing and commissioning of Class C GI pipe work for all pump suction / discharge line with common header complete with all fittings like elbow, tee, reducer, flange, union etc. conforming to IS:1239 (Part 1) for pipes and IS : 1879 (Part 1 to 10) for fittings including fixing in wall / ceiling / floor level, supported by galvanized clamps, hangers, vertical pipe support etc. Cost shall be inclusive of all hangers, clamps, brackets etc. shall be of galvanized iron unless specified otherwise and then supply of the same shall also be included for rates under this head. Also rates including flusing and chemical cleaning of pipes.Charges for Labelling of pipe as per color schedule over painted surface of the pipes. Location:pump room suction and delivery |
| 218 | E1.6.1.150mm nominal bore |
| 219 | E1.6.2.100mm nominal bore |
| 220 | E1.6.3.80mm nominal bore |
| 221 | E1.7.Supply installation testing and commissioning of Expansion bellows at pump delivery side with high tensile nylon/polyester cord body, high tensile nylon flanges with positive sealing, NEOPRENE rubber outer Cover & with Leakproof Abrasion resistant seamless lining of Rubber, Metal Retaining Rings embedded in body, including all necessary accessories like nuts, bolts etc. all complete of approved make as directed by the Engineer in charge. |
| 222 | E1.7.1.150mm nominal bore |
| 223 | E1.7.2.100mm nominal bore |
| 224 | E1.7.3.Supply & installation of Suitable Cement concrete foundation with plaster for pumps |
| 225 | E1.8.Supply, installation, testing and commissioning of Flanged butterfly valve of CI body SG iron rilson coated disc ,Working pressure not less than 16Kg/Sq.cm. Including rubber gasket, flanges, nuts, bolts, washers & painting complete as required. |
| 226 | E1.8.1.150mm nominal bore |
| 227 | E1.8.2.100mm nominal bore |
| 228 | E1.8.3.80mm nominal bore |
| 229 | E1.8.4.65mm nominal bore |
| 230 | E1.9.Supplying & fixing full way lever operated forged brass ball valve working pressure not less than PN30 with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. |
| 231 | E1.9.1.50mm nominal bore |
| 232 | E1.10.Supply & fixing of flanged C.I. body Dual plate Check valve of rating PN16 including rubber gasket, flanges, union, nuts, bolts, washers & painting complete as required. |
| 233 | E1.10.1.100mm nominal bore |
| 234 | E1.10.2.65mm nominal bore |
| 235 | E1.11.Supply, installation, testing and commissioning of dual flange Cast-iron 'Y'-Strainer (flanged) with stainless steel fine wire mesh perforated sheet basket with necessary flange / unions, nuts, bolts and wahsers complete as required. |
| 236 | E1.11.1.150mm nominal bore |
| 237 | E1.11.2.100mm nominal bore |
| 238 | E1.11.3.80mm nominal bore |
| 239 | E1.12.Supply, Installation, testing & commissioning of 100 mm dia dial type pressure gauge with pressure scale of 0 to 20 Kg / sqm. Coated rate shall be inclusive of isolation ball valve ,necessary fiitings etc., |
| 240 | E1.13.Supply, installation, testing and commissioning of capacitance rod type level controller for continious level monitoring of water tanks mounting top of the UG tanks .cost inclusive of cable from indicator to panel and display.Level controler should monitor the level of water tank and protect the pump from dry running .Necessary control logic should be consiered to make the system automatic as said above. Level controller should be compitable for IBMS hook up for monitoring the level of tank E1.13.1.Location: Under ground tanks (Over all depth of tank:0-5.0m) |
| 241 | E1.13.Supply, installation, testing and commissioning of capacitance rod type level controller for continious level monitoring of water tanks mounting top of the UG tanks .cost inclusive of cable from indicator to panel and display.Level controler should monitor the level of water tank and protect the pump from dry running .Necessary control logic should be consiered to make the system automatic as said above. Level controller should be compitable for IBMS hook up for monitoring the level of tank E1.13.1.Location: Under ground tanks (Over all depth of tank:0-5.0m) |
| 242 | 2.0 F-HVAC VRV Outdoor Units Supply, Lifting, Installation, Testing & Commissioning of inverter /Digital scroll compressor with Variable refrigerant system connectable to multiple indoor units. Outdoor unit shall be factory assembled weather proof casing constructed from heavy gauge mild steel panels. The unit shall be completely factory wired and tested with necessary controls and charged with refrigerant. The compressor shall be highly efficient scroll type. The aluminium fins shall be covered with anti-corrosion resin. Unit shall be equipped with oil recovery system to ensure stable operation with long refrigerant piping. Units shall be tested and commissioned with additional refrigerant. The unit shall be compatible for BMS/home automation operation (optional) Necessary relay card /soft integrator to be provided, Including rubber pads for outdoor units etc.Required converstor shall be used by hvac vendor to communicate to home automation/bms.Machines shall be derated to 40Deg C (DBT). |
| 243 | 10 HP |
| 244 | Special Refrigerant joints for VRV System Outdoor Supply and Installation of 18G Copper Piping insulated with19mm thick elastomeric nitrile rubber insulation and finished with polyshield coating with Necessary fittings, Y Joints and headers. (This includes the pressure testing and Refrigerant Gas charging ) between indoor & outdoor units as per specifications . All piping inside the room shall be properly supported with hanger and all external piping shall run in covered cably tray. Minor civil works like wall opening and closing for copper piping are included. (Incase any changes in the layout after approval, then the following unit rates shall be applicable.) |
| 245 | 34.92 mm dia |
| 246 | 19.05 mm dia COPPER CABLE Supply, laying & termination of following cable from Isolator to VRF Outdoor unit and from 10Amps power socket to indoor units with necessary supports, screws etc..( Isolator & power sockets to be provided by Electrical Vendor including the suitable cable up to isolators & sockets.) |
| 247 | 4C x 10Sqmm copper Armoured cable F.1 VENTILATION FANS |
| 248 | supply, installation and testing and commissioning of single/double skin cabinet inline fan with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip , Cowl piece with bird mesh and supporting arrangements. The fan motor shall be suitable for operating on 230V, 1 phase, 50Hz AC with ON/OFF Breaker ,The exposed Units should have Canopy for weather protection Note. Vibration isolator detail shall be submitted before installation to consultants/PMC for approval F1.1. 600 CFM-External static pressure -15 MM -without filter supply, installation and testing and commissioning of CIRCULAR INLINE FAN with all necessary supports. Unit shall be provided along with fire retardant flexible canvass with Zip , Cowl piece with bird mesh and supporting arrangements. The fan motor shall be suitable for operating on 230V, 1 phase, 50Hz AC with ON/OFF Breaker Direct driven PVC type Propeller fan ,rubber pad etc. complete,Each fan shall be complete with accesseries like finger proof steel wire guard at inside & Gravity louvers at outside of the fan .The fan shall be suitable for 230 volts ± 10% ,frequency 50Hz ± 5% , single phase AC supply ,Motor shall be with IP 54 protection .EFF1/ 2** efficiency & class F insulation,Suitable size of Cu flexible FRLS cable of length 5 meter with 3 pin plug top shall be included in the rates. |
| 249 | Toilet Exhaust fan - 650CFM |
| 250 | Supply, Laying & Termincation of 2C x 2Sqmm Armoured copper cable beween isolater to Exhaust Fan DUCTS / GRILLS / DAMPERS RECTANGULAR DUCT |
| 251 | Sheet Metal Work using with Ductmate/TDF Flanges for all sizes of the duct. Fabrication as per SMACNA Standards Galvanizing shall be Class VIII – light coating of zinc, nominal 120 gm / sqm surface area and Lock Forming Quality prime material alongwith mill test certificates. In addition, if deemed necessary, samples of raw material, selected at random by owner’s site representative shall be subject to approval and tested for thickness and zinc coating at contractor’s expense. All duct construction and installation shall be in accordance with SMACNA standards. In addition ducts shall be factory fabricated utilizing the following machines to provide the requisite quality of ducts.required Bottom of the support rubber pad shall be part of this line item All ducts shall be fabricated and installed in workmanlike manner, conforming to relevant SMACNA codes. The Duct shall be fabricated with required splitters dampers ,turning vanes & cleats.Ducting works with all sizes made of TDF ( Up to 1200 mm width ) & slip-on flange joints ( for more than 1200 mm in width ) as specified in technical specs -Factory fabricated Ducting -- for 500** Pascal test pressure as per IS 655:2006 standards . The Duct shall be supported with Hi-tech Supports at regular intervalas as mentioned in the technical specifications. Required ms supports shall be part of this line item.The bracing shall be as per ISS 655-1963. Supports for ducts shall be MS sections at 2.4m-distance apart up to 2250/1.2m distance apart for longer ductsWhere duct and clamp are of dissimilar material, a gasket shall be provided in between. Contractor shall ensure that all ducts with insulation are not in direct contact with the hangers (duct supports). duct should be store in site ,all the duct should be coverd in both side . Air balancing shall be done as required. Duct testing shall be acrreid out as per Smacna standard , smoke test & pressure test ,as direcetd by client/PMC Sheet Metal Ducting As per Specification. 18 G 20G 22 G F2.2. 24 G DOOR LOUVER Supply & fixing - Extruded Aluminimum powder coated louver without VCD with necessary GI Screw, bolt, nut & supports. ( colour for the grill to b conifremed by Arch/ PMC team before placing the order) EXTERNAL LOUVER Supply & fixing - Aluminimum powder coated LOUVER with BIRD SCREEN/MESH necessary GI Screw, bolt, nut & supports. ( colour for the Louvel to be confirmed by Arch/ PMC team before placing the order)required civil work like wall chasing ,wall cutout ,wall opening, and required finishing work shall be part of this line iem. FRESH/EXHAUST AIR GRILL Supply & Fixing of aluminium Fresh air/ Exhaust air powder coated grills with collar damber , color code shall be ar per architect approval 150x150-Grill with collar damper with plenum box 150x150-Grill with collar damper without plenum box CANVAS Supply Fabrication , and erection of Double canvas connection made out ,canvas should be atleast 2 hours fire rating required , fire retardent canvas cloth with Zip required necessary fixing arrangements including nuts & bolts Etc UNDER DECK INSULATION Supply and installation of Underdeck 25mm thickness insulation of class \\" O \\" Closed cell Nitrile rubber based elastomeric. The insulation shall have fire performance such that it passes Class 1 as per BS476 Part 7 for surface spread of flame as per BS 476 and also pass Fire Propagation requirement as per BS476 Part 6 to meet the Class ‘O’ Fire category as per 1991 Building Regulations (England & Wales) and the Building Standards (Scotland) Regulations 1990.Thermal conductivity of elastomeric nitrile rubber shall not exceed 0.035 W/m°K at an average temperature of 0°C. Material should be FM (Factory Mutual), USA approved. Moisture Diffusion Resistance Factor ‘µ’ value should be minimum 7000.this line item shall be use wherever its required to avoid the condensation. |
| 252 | 2.0 G-FIRE PROTECTION |
| 253 | G.1 FIRE PUMP ROOM EQUIPMENTS |
| 254 | G.1.1 Supply, Installation, Testing & Commissioning (SITC) of The Electrical motor driven pump, common stand by pump of horizontal centrifugal end suction backpull out type with gland packing and capable to deliver. The pump shall be coupled to S1 DUTY TEFC IE3 motor of suitable HP with speed of 2950 RPM and complete set shall be mounted on common base frame for pump and motor from M.S. Channel of required size with epoxy coated edging complete with Antivibration pads with bolt & nuts for the pumps to be considered. (Common Pump for Hydrant & Sprinkler system) The pump shall be capable of giving a discharge of not less than 150 per cent of the rated discharge, at a head of not less than 65 per cent of the rated head. The shut off head shall be within 120 per cent of the rated head. The motor shall be squirrel cage A.C. induction type suitable for operation on 415 volts 3 phase 50 Hz. system. The motor shall be totally enclosed fan cooled type conforming to protection clause IP 55 & Class F insulation. The synchronous speed shall be 2950 RPM as specified. The motor shall be rated for continuous duty and shall have a horse power rating necessary to drive the pump at 150 per cent of its rated discharge with at least 65 percent rated head. The motor shall conform to I.S.325-1978. |
| 255 | G.1.1 Supply, Installation, Testing & Commissioning (SITC) of The Electrical motor driven pump, common stand by pump of horizontal centrifugal end suction backpull out type with gland packing and capable to deliver. The pump shall be coupled to S1 DUTY TEFC IE3 motor of suitable HP with speed of 2950 RPM and complete set shall be mounted on common base frame for pump and motor from M.S. Channel of required size with epoxy coated edging complete with Antivibration pads with bolt & nuts for the pumps to be considered. (Common Pump for Hydrant & Sprinkler system) The pump shall be capable of giving a discharge of not less than 150 per cent of the rated discharge, at a head of not less than 65 per cent of the rated head. The shut off head shall be within 120 per cent of the rated head. The motor shall be squirrel cage A.C. induction type suitable for operation on 415 volts 3 phase 50 Hz. system. The motor shall be totally enclosed fan cooled type conforming to protection clause IP 55 & Class F insulation. The synchronous speed shall be 2950 RPM as specified. The motor shall be rated for continuous duty and shall have a horse power rating necessary to drive the pump at 150 per cent of its rated discharge with at least 65 percent rated head. The motor shall conform to I.S.325-1978. |
| 256 | H1.FIRE ALARM PANEL |
| 257 | H1.1.Supply, Installation, Testing & Commissioning of Microprocessor based Intelligent Analog Addressable Type 8 Loops Fire Alarm Control Panel with with auto dailer with 160 character LCD display, four access level. 1000 event historic logging, flash EPROM sufficient numbers of programmable relay control, 240V DC standby & Battery backup/battery charger minimum of 24 hrs (please provide battery calculations), auto dialer, built in or external continuous on line printer.. The FACP shall have provision of loop expansion, The FACP shall be networkable type. The FACP shall also house inbuilt 120W mixed amplifier for firemen communication system. The FACP loops is designed considering 125 detectors & devices per loop and each loop is loaded 80%.FA Panel should have provision of RS 485 MODBUS/Bacnet protocal for BMS integration |
| 258 | H2.REPEATER PANEL |
| 259 | H2.1.Supply, Installation, Testing & Commissioning of remote annunciators with 4 line 80 character LCD display. The annunciator shall have built in memory to record the alarm events and shall have standard buttons for alarm ack, reset etc. Max of 32 remote annunciators shall be loopable to one FACP. |
| 260 | H3.DETECTORS |
| 261 | H3.1.Photo Detectors: Supply, Installation, Testing and Commissioning of Intelligent Addressable Photo Electric Type Smoke Detectors Above False Ceiling with indicating lamp, mounting base and all other mounting accessories complete as required. |
| 262 | H3.2.Photo Detectors: Supply, Installation, Testing and Commissioning of Intelligent Addressable Photo Electric Type Smoke Detectors - Below False Ceiling with indicating lamp, mounting base and all other mounting accessories complete as required. |
| 263 | H3.3.Photo Detectors: Supply, Installation, Testing and Commissioning of Intelligent Addressable Photo Electric Type Smoke Detectors - Below False Flooring with indicating lamp, mounting base and all other mounting accessories complete as required. |
| 264 | H3.4.Heat Detector (Addressable): Supply, Installation, Testing and Commissioning of Intelligent Addressable Heat Detectors with indicating lamp, mounting base and all other mounting accessories complete as required. |
| 265 | H3.5.Multi Sensor Detector: Supply, Installation, Testing and Commissioning of Intelligent Addressable Multi Sensor Detectors with indicating lamp, mounting base and all other mounting accessories complete as required. |
| 266 | H3.6.Response Indicator: Supply, Installation, testing and commissioning of Response Indicator with all mounting accessories complete as required. |
| 267 | H4.DEVICES |
| 268 | H4.1.Isolator Module: Supply, Installation, testing and commissioning of Isolator Module with indicating lamp, mounting base and all other mounting accessories complete as required. |
| 269 | H4.2.Manual Call Points: Supply, Installation, testing and commissioning of Intelligent Addressable Manual Call Points with indicating lamp, mounting base and all other mounting accessories complete as required. |
| 270 | H4.3.Control Module for Hooter: Supply, Installation, testing and commissioning of Addressable Control Modules for activating hooters with all the mounting accessories complete as required. One CM shall provide one activation signals. |
| 271 | H4.4.Control Module for Fire Damper: Supply, Installation, testing and commissioning of Addressable Control Modules for activating hooters with all the mounting accessories complete as required. One CM shall provide one activation signals. |
| 272 | H4.5.Control Module for Access Controllers System Integration: Supply, Installation, testing and commissioning of Addressable Control Modules for overriding access door command with all the mounting accessories complete as required. |
| 273 | H4.6.Control Module for Base builder FA Panel Integration: Supply, Installation, testing and commissioning of Addressable Control Modules for Base builder FA Integration with all the mounting accessories complete as required. (Base builder Need to add One no. of Monitor Module for Integration) |
| 274 | H4.7.Control Module for PA Integration: Supply, Installation, testing and commissioning of Addressable Control Modules for overriding PA system with all the mounting accessories complete as required. One CM shall provide one activation signals. |
| 275 | H4.8.Relay Module for High Voltage Applications: Supply, Installation, testing and commissioning of Addressable Relay Modules for Tripping the AHU's Equipments with all the mounting accessories complete as required. |
| 276 | H4.9.Monitor Module: Supply, Installation, testing and commissioning of Addressable Monitor Modules for Interfacing PFC/Dry Inputs of Fire Pump Signals, Sprinkler Line Flow Switch Status, Base builder fire alarm panel integration with all the mounting accessories complete as required. |
| 277 | H5.Panic Bars |
| 278 | H5.1.Supply, Installation, Testing & Commissioning of Panic Bars. The panic bar shall have Lock, local hooter, and potential free contacts for integration with FAS or BMS |
| 279 | H6.NOTIFICATION DEVICES |
| 280 | H6.1.Hooters: Supply, Installation, testing and commissioning of ceiling type Hooters with all mounting accessories complete as required. |
| 281 | H6.2.Hooters with Strobes: Supply, Installation, testing and commissioning of Hooters with Strobes with all mounting accessories complete as required. |
| 282 | H7.CABLES, CONDUITS: |
| 283 | H7.1.Supply, wiring, testing and commissioning of ISI Certified 2Cx1.5 sq.mm, twisted shield, FRLS type, armored double insulated copper cable with Ferrules, Lugs, saddles, saddles base & other accessories complete as required. The cable specification shall meet FACP & detectors manufacturer requirement. (Including hooter cabling) |
| 284 | 2.0 I-PUBLIC ANNOUNCEMENT |
| 285 | I. PA Rack |
| 286 | I.1.1.Supply, Installation, Testing & Commissioning of sheet metal 15U rack (or vendor shall calculate and propose suitable rack) for mounting of PAS Controller & Amplifier as per the technical specification with all mounting accessories etc |
| 287 | I2.System Controller |
| 288 | I2.1.Supply, Installation, Testing & Commissioning of Programmable System Controller with built in Amplifier, zone selection for 2 zones, and All Call having 1st level priority for DVR (Fire message), 2nd level for Announcement, least level for Music. And also built in monitoring facility as per the technical specification with all mounting accessories etc |
| 289 | I3.Zone Selector with Microphone |
| 290 | I3.1.Supply, Installation, Testing & Commissioning of Call Station with Multiple zone selector extension card and Gooseneck Microphone. For Reception with all mounting accessories etc |
| 291 | I5.Booster Amplifiers |
| 292 | I5.1.Supply, Installation, Testing & Commissioning of Booster Amplifier for PA system with RMS output (actual) 480 W with all mounting accessories etc. |
| 293 | I5.2.Supply, Installation, Testing & Commissioning of Booster Amplifier for PA system with RMS output (actual) 240 W with all mounting accessories etc. |
| 294 | I6.Speakers |
| 295 | I6.1.Ceiling Mount Type Without Mounting Box : Supply, Installation, Testing & Commissioning of Ceiling mount type Round Speakers of 6 Watts Rated Power with Dual Cone High Sensitivity Loudspeaker Drivers, Opening Angle of 180o and builtin 100 Volts Matching Transformer. The Speaker Cabinet shall be White Color with mounting base and all other mounting accessories complete as required. |
| 296 | I6.2.Mounting Box for Ceiling speaker : Supply, Installation, Testing & Commissioning of mounting box for Round Speakers of 6 Watts Rated Power with Dual Cone High Sensitivity Loudspeaker Drivers, Opening Angle of 180o and builtin 100 Volts Matching Transformer. The Speaker Cabinet shall be White Color with mounting base and all other mounting accessories complete as required. |
| 297 | I6.3.BOX Speaker: Supply,installation & commissioning of 6 W rated Horn Speakers with wall mounting brackets other required mounting accessories |
| 298 | I7.Cable & Conduit |
| 299 | I7.1.Supply, Laying, Terminating, Testing & Commissioning of 2 core 24/0.2 mm ATC twin twisted, FRLS type Unarmored Cable as per the technical specification with all mounting accessories etc |
| 300 | I7.2.Supply & Laying of FRLS Conduit of 3/4” dia & 2mm thickness with accessories like saddles, saddle base etc complete as required as per the technical specification with all mounting accessories etc |
| 301 | 2.0 J-CCTV |
| 302 | J1.Supply, Installation,Testing Commissioning of IP Based CCTV System comprising of following: |
| 303 | J1.1.Supply, Installation, Testing & Commissioning of Indoor 1/3\\" CCD Dome colour camera ensure HD 1080P resolution, 5 Mega pixel ,IR Camera(Day/Night) 2.8mm to 12mm varifocal lens with mounting accessories -IP based |
| 304 | J1.2.Supply, Installation, Testing & Commissioning of IP Varifocal bullet POE Camera, 5MP, support 1080p,1/3\\" Progressive CMOS, ICR with IR, , The bullet camera shall install indoor / outdoor areas. Power supply to be taken from Ethernet cable. Camera should be above to cover a distance of (30 / 50) Mtrs minimum. |
| 305 | J1.3.Multilens(3.6mm) camera with IR for 360° coverage,1/3'' 4MP PS CMOS Image sensor,Camera should be above to cover a distance of 30 Mtrs minimum,WDR (120dB), Day/Night (ICR), 3D NR, ROI, AWB, AGC, BLC, HLC. |
| 306 | J2.NVR |
| 307 | J3.MONITOR |
| 308 | J3.1.Supply, Installation, Testing & Commissioning of 42'' LCD Monitors complete with wall mount kit |
| 309 | J3.2.Supply, Installation, Testing and Commissioning of15U Wall mounted Rack. |
| 310 | J4.CABLE & CONDUIT |
| 311 | J4.1.Supply, Installation, Testing & Commissioning of 24 port layer 2 switch with 10/100/1000 POE Manage Switches with IP multicast snooping and data-driven IGMP support and with two 1000baseT single mode FO uplink ports and all related termination accessories as per site specific System requirement. |
| 312 | J4.2.Supply Laying, Terminating & Testing of Unarmoured Cat-6 cable, laid on Surface with required terminations as required with Cable tie`s & Tags. |
| 313 | J4.3.Supply & Laying of FRLS Conduit of 3/4” dia & 2mm thickness with accessories like saddles, saddle base etc complete as required as per the technical specification with all mounting accessories etc |
| 314 | 2.0 K-HT PANEL K1.RING MAIN GEAR |
| 315 | K1.1.Supply of 11KV, 25 KA, 630A, Outdoor type Ring Main Gear (RMG) as per the specification and annexure 11KV 25KA 630Amps HT RING MAIN GEAR comprising of Two Incoming Air Break Load Break Switches and One Outgoing HT Vacuum Circuit Breaker for OUTDOOR Installation RMG K1.1.Vaccum Circuit Breaker K1.1.1.11KV, 630A, 25KA Horizontal Draw out/isolation VCB fitted with Manual/Motor operated spring charging mechanism with 230V AC motor and motor control switch, shunt trip coil of 110V DC, closing coil of 110V DC, Auxiliary Contact 4NO+4NC, Mechanical ON/OFF indicator, mechanical operation counter, Anti pumping feature, Automatic safety shutters and Push button K1.2.Load Break Swith K1.2.1.11kV 630A, 25kA, Load break switch with Earth switch, with 2NO+2NC Aux. Contact, Spring charged mechanism Manually operated K1.3.Potential Transformer K1.3.1.Three Phase, Resin Cast, Dry type, Draw out PT with HT/LT fuses of ratio (11KV/1.732)/(110V/1.732), Core 1:Cl. 0.2 50VA K1.4.Current Transformer K1.4.1.Single phase, Resin Cast, Dry Type Current Transformer of suitable ratio/5-5A, Core 1: Cl. 0.5 / 15VA for metering, Core 2: Cl. 5P10 / 15VA for protection K1.5.Meters K1.5.1.Analog Ammeter with 5 Position selector switch K1.5.2.Analog Voltmeter with selector switch Provision for digital Trivector Meter L & T (or) Secure Make K1.6.Protection Relays K1.6.1.Numerical type Triple-pole Non-Directional, IDMT, 2O/C + 1E/F with High set with 1.3 Sec M140A K1.7.Auxiliary Relays K1.7.1.Master trip Relay-MVAJH 13 K1.8.Indication Lamps K1.8.1.VCB On/OFF/Auto Trip/Spring Charge/Trip Circuit Healthy Indication Lamps K1.8.2.R,Y,B Phase Indication Lamps K1.9.Control Switches K1.9.1.Breaker Control Switch (Close-Neutral-Trip) K1.9.2.Local/Remote Selector switch K1.9.3.Test Terminal Block-Nelster Make/Reputed K1.10.Bus Bars K1.10.1.Main Bus: 630Amps Copper Bus bar with PVC Sleeve insulation K1.11.Common for Switch gears K1.11.1.Control wiring with 2.5sqmm wire in appropriate colour K1.11.2.Heater ON/OFF switch with filament type 80W space heater and thermostat, Single phase switch with socket, Cubicle illumination lamp, Door limit switch, MCBs / Fuses for AC / DC Control K1.11.3.Auxiliary DC Power Source – 230V AC to 110V DC K1.12.Enclosure K1.12.1.MS Sheet steel suitable for Outdoor Installation Powder Coated with Siemens Grey Paint finish K1.13.Termination K1.13.1.Incoming (Excluding cable termination kits, lugs and glands) K1.13.2.Outgoing (Excluding cable termination kits, lugs and glands) K1.14.Others K1.14.1.Mechanical ON/OFF Indication K1.14.2.Manual Trip Push Button K1.14.3.Panel Mounting Surge Arrester-9KV,10KA |
| 316 | K2.HT PANEL - POINT OF SUPPLY Supply of 630A 11kV HT VCB Panel for OUTDOOR Installation K2.1.11KV, 25 KA, 630A, OUTDOOR SINGLE PANEL VACCUM CIRCUIT BREAKER complete as per Specification Sub total VAT @ 14.5% TotalProvision to receive Incoming/Outgoing cable excluding cable glands and cable termination Kit etc., K2.SINGLE HT PANEL - POINT OF SUPPLY K2.1.Vaccum Circuit Breaker K2.1.1.Horizontal Draw Out VCB fitted with Manual / Motor Operated mechanism with 230V AC Motor & Motor Control Switch, Mechanical ON / OFFspring charging, indicator Operation Counter, Automatic safety shutters & push button, Shunt trip Coil Closing Coil Spare auxiliary contact Anti pumping Feature K2.1.2.Power Pack K2.2.Potential Transformer K2.2.1.Three Phase, Resin Cast, Dry type, Draw out PT with HT/LT fuses of ratio (11KV/1.732)/(110V/1.732), Core 1: K2.3.Current Transformer K2.3.1.Single phase, Resin Cast, Dry Type Current Transformer of suitable ratio/5-5A, Core 1: Cl. 0.5 / 15VA for metering, Core 2: Cl. 5P10 / 15VA for protection K2.4.Meters K2.4.1.Digital Ammeter with selector switch K2.4.2.Digital Voltmeter with selector switch K2.4.3.Provision for digital Multi Function Meter K2.5.Protection Relays K2.5.1.Numeric Non directional IDMT combined 3O/C+1 E/F relay with high set K2.5.2.High speed /Master trip relay K2.6.Indication Lamps K2.6.1.VCB On/OFF/Auto Trip/Spring Charge/Trip Circuit Healthy Indication Lamps K2.6.2.R,Y,B Phase Indication Lamps K2.7.Control Switches K2.7.1.Breaker Control Switch (Close-Neutral-Trip) K2.7.2.Local/Remote Selector switch K2.7.3.Flush Head type Trip Circuit Healthy Push Button K2.8.Bus Bars K2.8.1.Main Bus: 630Amps Copper Bus bar with PVC Sleeve insulation K2.9.Common for Switch gears K2.9.1.Control wiring with 2.5sqmm wire in appropriate colour K2.9.2.Heater ON/OFF switch with filament type 80W space heater and thermostat, Single phase switch with socket, Cubicle illumination lamp, Door limit switch, MCBs / Fuses for AC / DC Control K2.9.3.Auxiliary DC Power Source – 230V AC to 110V DC K2.10.Enclosure K2.10.1.MS Sheet steel suitable for Outdoor Installation Powder Coated with Siemens Grey Paint finish K2.11.Termination K2.11.1.Incoming (Excluding cable termination kits, lugs and glands) K2.11.2.Outgoing (Excluding cable termination kits, lugs and glands) K2.11.3.Panel Mounting Surge Arrester-9KV,10KA |
| 317 | L1.250kVA Outdoor Type Unitized Substation L1.1.Supply erection testing and commissioning of 250kVA outdoor type Unitized substation with following specification,11KV 25KA 630Amps HT VCB -1No. As HT incomer specification,250kVA Dry type transformer with OLTC -1No. As transformer specification - Copper Busbar,630A, 4P, MDO Indoor type 50KA, Microprocessor based MCCB inbuilt overload, short circuit and earth fault release with CT including Interconnecting with Multifunction meter and indicating lamps -1No. Bus bar Copper, Note : - The specification of the Panel should be approved by TNEB, Provision to receive Incoming/Outgoing cable excluding cable glands and cable termination Kit etc., SINGLE HT PANEL - TRANSFORMER PROTECTION Vaccum Circuit Breakern 630A, 350MVA. Horizontal Draw Out VCB with Manual/230V AC Motor Operated Spring Charging Mechanism with 110V DC Closing /Opening Shunt trip coils, Aux. Switch, Mechanical On/Off Push Butto , and mechanical Operating Counter, Shunt trip Coil-110V DC, Closing Coil110V DC, Spare auxiliary contact 4NO +4 NC,Anti pumping Feature110V DC, Power Pack230V AC TO 110V DC-1no Potential Transformer Three Phase, Resin Cast, Dry type, Draw out PT with HT/LT fuses of ratio (11KV/1.732)/(110V/1.732), Core 1: Current Transformer Single phase, Resin Cast, Dry Type Current Transformer of suitable ratio/5-5A, Core 1: Cl. 0.5 / 15VA for metering, Core 2: Cl. 5P10 / 15VA for protection Meters Digital Ammeter with selector switch Digital Voltmeter with selector switch Provision for digital Multi Function Meter Protection Relays Numeric Non directional IDMT combined 3O/C+1 E/F relay with high set High speed /Master trip relay Transformer fault annunciator on type auxiliary relay Auxiliary Relay for OLTC Indication Lamps VCB On/OFF/Auto Trip/Spring Charge/Trip Circuit Healthy Indication Lamps R,Y,B Phase Indication Lamps Control Switches Breaker Control Switch (Close-Neutral-Trip) Local/Remote Selector switch Flush Head type Trip Circuit Healthy Push Button Annunciator- 8 Window Buzzer Bus Bars Main Bus: 630Amps Copper Bus bar with PVC Sleeve insulation Common for Switch gears Control wiring with 2.5sqmm wire in appropriate colour Heater ON/OFF switch with filament type 80W space heater and thermostat, Single phase switch with socket, Cubicle illumination lamp, Door limit switch, MCBs / Fuses for AC / DC Control Auxiliary DC Power Source – 230V AC to 110V DC Enclosure MS Sheet steel suitable for Indoor Installation Powder Coated with Siemens Grey Paint finish Termination Incoming (Excluding cable termination kits, lugs and glands) Outgoing (Excluding cable termination kits, lugs and glands) Panel Mounting Surge Arrester-9KV,10KA 250kVA Transformer Dry Type Supply of Transformer with following specification 11KV/433V INDOOR DRY TYPE CAST RESIN TRANSFORMER WITH OLTC/RTCC/AVR Impedence : 5.5%/IS Tolerence No Load Loss : 1.9kW,Load Loss : 8.5kW, Including Neutral CT and all other standard accessories complete set,Approved Makes:-ESENNAR / CREL / KIRLOSKAR / VOLTAMP |
| 318 | 2.0 M-ELECTRICAL |
| 319 | NOTE: 01. Unloading, receiving at SITE, loading storing and leading shall be contractors account only.02. Refer Schematic diagram and all panels should be as per the Schematic diagram only. LT PANELS CHECK LIST Vendor should refer SLD for more details, Vendor should get GA drawing approval before fabrication,A Technical specification and make of materials should be get approved before the procurement of the materials,For Bus bars - 0.8A/Sqmm for Al & Earthing should be twin earthing,The withstanding capacity mentioned is Ics only, All MCCB should be with adjustable overload and fixed short circuit relays, All MCCB upto 250A should be with thermal magnetic release (O/C & S/C) and 250A & above should be with micro processer release (O/C & S/C),All outgoing MCBs should be fixed inside the panel with view glass,All Incoming breakers should be 4P and outgoing breaker should be TPN ,The Panel board construction should be 3B construction,All Incoming breakers should be with shunt trip facility for remote operation,All the meters should have RS 485 modbus output for BMS integration,Multi functionmeter should be with following parameters ; Volts, Amps, F, PF, W/VA, Wh /Vah (),All Incoming & Outgoing breaker should be with ON/OFF/TRIP indication lamps as per SLD,All ACB should be with O/C, SC, E/F Release,All Incoming breaker (ACB ) should have built-in RS 485 port,All starter feeders (DOL & Star Delta Starter) should be considered as per Type-II Cordination Chart suitable for IE -2 motors M1 MV PANEL M1.1 Supply erection testing and commissioning of MV cubicle type suitable for 415V, 3-phase, 4 wire system, compatible to BMS totally enclosed floor mounted type, dust, damp and vermin proof main distribution board with made out of 16 SWG MS sheet complete with bus bars, MV danger notice plate,Dual source multifunction meter protection relays, digital multi funtion meter/Load manager with RS 485, CTs interconnections with suitable capacity / solid Copper strips, connection of incoming and outgoing cables with thimbles, electrostatically powder coated and having following incoming and outgoing switchgear complete with suitable size to accommodate the following accessories as per single line diagram, specification and as required. M1.2 Incomer .. 2No, 630 Amps 35kA 4Pole MicroProcessor based MCCB, Metering CT : 630/5A, Cl:1.0 ,15VA - 3Nos for Metering, Machanicalinterlocking,Earth Fault Relay - 1 Set ,Breaker ON/OFF/TRIP & RYB indicating lights with control MCB’s 1 Set,Surge Protection Devcie - 1 Set,APFC Relay - 1 Set. Outgoing - i)400A 25kA TPN Micro Processor based MCCB - 3 Nos.,ii)125A 25kA TPN MCCB - 1 Nos. NOTE: 01.The withstanding capacity mentioned is Ics only,02. All MCCB should be with adjustable overload and fixed short circuit relays,03. The Surge arrester should be class B/Type -1 for the protection of Lightning surge of 10/350µs wave form for EB Incomer,04. 100% Neutral busbar,BUSBAR : Aluminium RATING : 630 AMPS M2 POWER PANEL |
| 320 | M2.1Supply erection testing and commissioning of MV cubicle type suitable for 415V, 3-phase, 4 wire system, compatible to BMS totally enclosed floor mounted type, dust, damp and vermin proof main distribution board with made out of 16 SWG MS sheet complete with bus bars, MV danger notice plate,Dual source multifunction meter protection relays, digital multi funtion meter/Load manager with RS 485, CTs interconnections with suitable capacity / solid Copper strips, connection of incoming and outgoing cables with thimbles, electrostatically powder coated and having following incoming and outgoing switchgear complete with suitable size to accommodate the following accessories as per single line diagram, specification and as required. EB Incomer .. 1No,400 Amps 35kA 4Pole microprocessor based MCCB,Metering CT : 400/5A, Cl:1.0 ,15VA - 3Nos for Metering,Earth Fault Relay - 1 Set,Breaker ON/OFF/TRIP & RYB indicating lights with control MCB’s 1 Set,Surge Protection Devcie - 1 Set,APFC Relay - 1 Set,Outgoing - i)160A 25kA TPN based MCCB - 2 Nos,ii)100A 25kA TPN based MCCB with Dual source Multi Function Meter with RS485 Port-7 Nos,iii)100A 25kA TPN based MCCB - 2 Nos.NOTE: 01.The withstanding capacity mentioned is Ics only,02. All MCCB should be with adjustable overload and fixed short circuit relays,03. The Surge arrester should be class B/Type -1 for the protection of Lightning surge of 10/350µs wave form for EB Incomer,04. 100% Neutral busbar,BUSBAR : Aluminium RATING : 415 AMPS M3 COMMON AREA PANEL |
| 321 | M3.1 Supply erection testing and commissioning of MV cubicle type suitable for 415V, 3-phase, 4 wire system, compatible to BMS totally enclosed floor mounted type, dust, damp and vermin proof main distribution board with made out of 16 SWG MS sheet complete with bus bars, MV danger notice plate,Dual source multifunction meter protection relays, digital multi funtion meter/Load manager with RS 485, CTs interconnections with suitable capacity / solid Copper strips, connection of incoming and outgoing cables with thimbles, electrostatically powder coated and having following incoming and outgoing switchgear complete with suitable size to accommodate the following accessories as per single line diagram, specification and as required. M3.2 EB Incomer .. 1No, 400 Amps 35kA 4Pole based MCCB,Metering CT : 400/5A, Cl:1.0 ,15VA - 3Nos for Metering,Earth Fault Relay - 1 Set, Breaker ON/OFF/TRIP & RYB indicating lights with control MCB’s 1 Set,Surge Protection Devcie - 1 Set,APFC Relay - 1 Set, Outgoing - i)250A 25kA TPN based MCCB - 1 Nos,i)63A 25kA TPN based MCCB - 7 Nos.ii)40A 25kA TPN based MCCB - 4 Nos.ii)32A 10kA DP MCB - 1 Nos.NOTE: 01.The withstanding capacity mentioned is Ics only,02. All MCCB should be with adjustable overload and fixed short circuit relays,03. The Surge arrester should be class B/Type -1 for the protection of Lightning surge of 10/350µs wave form for EB Incomer,04. 100% Neutral busbar,BUSBAR : Aluminium RATING : 415 AMPS M4 70KVAR APFC Panel |
| 322 | M4.1.Supply of MV cubicle type suitable for 415V, 3-phase, 4 wire system, compatible to BMS totally enclosed floor mounted type, dust, damp and vermin proof main distribution board with made out of 14 SWG MS sheet complete with bus bars, MV danger notice plate, protection relays, digital multi funtion meter with RS 485, CTs interconnections with suitable capacity / solid aluminium strips, connection of incoming and outgoing cables with thimbles, electrostatically powder coated and having following incoming and outgoing switchgear complete with suitable size to accommodate the following accessories as per single line diagram, specification and as required. Incomer - 160 Amps 4Pole 25kA MCCB-1No. OUTGOING : 63 AMPS 10kA TPN MCB with 20KVAR Capacitor Duty Contactor: 2Nos.40 AMPS 10kA TPN MCB with 10KVAR Capacitor Duty Contactor: 2Nos.20 AMPS 10kA TPN MCB with 5KVAR Capacitor Duty Contactor: 2Nos. Note;01. All MCCBs shall have Adjustable Overload and Short Circuit setttings. 02. The withstanding capacity shall be Ics only.An 6-Step APFC Relay with transducer shall be incorporated to maintain the power factor. The Panel shall also be made suitable to accommodate the following Capacitor Banks with all interconnections. Contactor switching should be with necessary protection fuse etc., 20KVAR .. 2 Nos. 7% Detuned with harmonic filters, 10KVAR .. 2 Nos. 7% Detuned with harmonic filters,5KVAR .. 2 Nos. 7% Detuned with harmonic filters,BUSBARS : ALUMINIUM RATING : 160 AMPS, There shall be One Set of Metering Compartment incorporated with the following for Incomer:- Metering CT : 160/5A, Cl:160,5VA - 3Nos for Metering,Digital Ammeter with Selector Switch,Digital Voltmeter with Selector Switch, Breaker ON/OFF/TRIP & RYB indicating lights with control MCB’s 1 Set M5. MCB DBs |
| 323 | M5.1.Supplying, fixing, connecting & commissioning the following Compartmentalised MCB DISTRIBUTION BOARDS fixed flush with the wall. All MCB DBs shall be double door only. Note :-B Curve MCB should be used for Lighting DB ,C Curve MCB should be used for Raw Power DB, D Curve MCB should be used for UPS DB, All Sigle Phase Distribution boards should be 7 Segmented DB, All RCCB should be with 30mA breaking capacity,All DBs shall have incoming adopter box (Powder coated) to receive wires in pipes / cables etc. The adopter box shall have a minimum height of 150mm. M5.2.LIGHT DISTRIBUTION BOARD (LDB) 7 Segmented DB - Common Area Lighting DB - Supply, ercetion, testing and commissioning of 4 way TPN DB with following specifications. INCOMER : 40 AMPS 4 P MCB .. 1 No. OUTGOING : 32 AMPS D P 30 mA RCBO .. 3 Nos. 6/10 AMPS SP MCB .. 12Nos. |
| 324 | M5.3.EMERGENCY LIGHITNG DISTRIBUTION BOARD (ELDB) Supply, ercetion, testing and commissioning of 8 way SPN DB with following specifications. INCOMER : 32 AMPS DP RCCB .. 1 No. OUTGOING : 10/6 AMPS SP MCB .. 6nos. |
| 325 | M5.4.CRITICAL DB - Supply, ercetion, testing and commissioning of 8 way SPN DB with following specifications. INCOMER : 32 AMPS DP RCCB .. 1 No. OUTGOING : 10/6 AMPS SP MCB .. 6nos. |
| 326 | M5.5.POWER DISTRIBUTION BOARD (PDB) - Supply, ercetion, testing and commissioning of 4 way TPN DB with following specifications. INCOMER : 40 AMPS 4 P MCB .. 1 No. OUTGOING : -32 AMPS D P 100 mA RCBO .. 3 Nos.,16/25 AMPS SP MCB .. 12Nos. |
| 327 | M5.6.EXTERNAL DISTRIBUTION BOARD (EXDB) - Supply, ercetion, testing and commissioning of 4 way TPN DB with following specifications. INCOMER : 40 AMPS 4 P MCB .. 1 No. OUTGOING : 25 AMPS D P 30 mA RCBO .. 3 Nos. 10/16/25 AMPS SP MCB .. 12Nos. |
| 328 | M5.7.LIFT DISTRIBUTION BOARD (LIFT DB) Supply, ercetion, testing and commissioning of 12 way SPN DB with following specifications. INCOMER : 40 AMPS 4P MCB .. 1 No. OUTGOING : 32 AMPS TP MCB .. 1 No. 16 AMPS DP MCB .. 1 No. 6 AMPS DP MCB .. 1 No. |
| 329 | M5.8.PHE DB - Supply, ercetion, testing and commissioning of 12 way SPN DB with following specifications. INCOMER : 63 AMPS 4P MCB .. 1 No. OUTGOING : 25 AMPS SP MCB .. 4nos. 16 AMPS SP MCB .. 4nos. M6.CABLES/TERMINATIONS |
| 330 | Supply, Laying, connecting and commissioning the following 1.1KV Grade AYFY/YFY/YWY Under Ground cables with necessary clamps screws etc. and the cables shall be laid in trench/clamped along wall/column/laid in cable tray etc(the rates inclusive of suitable clamps, screws etc but exclusive of cable tray complete. |
| 331 | M6.1. 3C x 185Sqmm Al 11kV XLPE Cable ( HT CABLE ) |
| 332 | M6.2. 3.5C x 240Sqmm Al XLPE Cable |
| 333 | M6.3. 3.5C x 185Sqmm Al XLPE Cable (FIRE PANEL) |
| 334 | M6.4. 3.5C x 150Sqmm Al XLPE Cable (PANEL) |
| 335 | M6.5. 3.5C x 70Sqmm Al XLPE Cable (APFC) |
| 336 | M6.6. 3.5C x 50Sqmm Al XLPE Cable (PANEL) |
| 337 | M6.7. 3.5C x 35Sqmm Al XLPE Cable upto isolator panel |
| 338 | M6.8. 4C x 10Sqmm Cu XLPE Cable (car elevator) |
| 339 | M6.9. 4C x 6Sqmm Cu XLPE Cable (PHE/LDB/PDB/EXDB) |
| 340 | M6.10. 4C x 6Sqmm Cu Flex Cable (LIFT) |
| 341 | M6.11. 3C x 6Sqmm Cu flexible Cable |
| 342 | Supplying, terminating, connecting & commissioning the above underground cables with double compression type glands with all sockets etc complete M6.12. 3.5C x 185Sqmm Al 11kV XLPE Cable ( HT CABLE ) |
| 343 | M6.13. 3.5C x 240Sqmm Al XLPE Cable |
| 344 | M6.14. 3.5C x 185Sqmm Al XLPE Cable (FIRE PANEL) |
| 345 | M6.15. 3.5C x 150Sqmm Al XLPE Cable (PANEL) |
| 346 | M6.16. 3.5C x 70Sqmm Al XLPE Cable (APFC) |
| 347 | M6.17. 3.5C x 50Sqmm Al XLPE Cable (PANEL) |
| 348 | M6.18. 3.5C x 35Sqmm Al XLPE Cable upto isolator panel |
| 349 | M6.19. 4C x 10Sqmm Cu XLPE Cable (car elevator) |
| 350 | M6.20. 4C x 6Sqmm Cu XLPE Cable (PHE/LDB/PDB/EXDB) |
| 351 | M6.21. 4C x 6Sqmm Cu Flex Cable (LIFT) |
| 352 | M6.22. 3C x 6Sqmm Cu flexible Cable |
| 353 | M7.ISOLATORS |
| 354 | M7.1. 100A 4P Isolator with IP55 Manufacture's enclosure MCB Type(Floor) |
| 355 | M7.2. 63A 4P Isolator with IP65 Manufacture's enclosure MCB Type(Lift) |
| 356 | M7.3. 40A DP Isolator with IP55 Manufacture's enclosure MCB Type(Inverter) |
| 357 | M7.4. 25A 4P Isolator with IP55 Manufacture's enclosure MCB Type(Pump) |
| 358 | M7.5. 25A DP Isolator with IP55 Manufacture's enclosure MCB Type(Mechanical parking) M8. EARTHING |
| 359 | Supply erection testing and commissioning of Maintenance Free Earthing system comprising of 14.2 mm dia 3 mtr long Earth electrode of low carbon steel electrode with 250 micron copper bonding & 1 bag of Carbon based Ecosafe environment friendly backfill and suitable clamp, as per IS 3043. CPRI test report should be produced at the time of supply including the inspection chamber, cover HDPE complete set. M8.1. DG Set .. 2 Sets, LT Panel .. 2 Sets, Lightning Arrestor .. 2 Sets, UPS .. 2 Sets, Lift .. 4 Sets |
| 360 | Supply erection testing and commissioning of Earth Electrodes, 17.2mm dia copper bonded steel rod 3meter length, 100 micron , along with jef corbon based ecosafe backfill compound 50 pounds , along with tin coated copper clamp.CPRI test report should be produced at the time of supply.including the inspection chamber, cover HDPE complete set. M8.2. DG Set .. 2 Sets, Tenants : 14 Set ( Space provision only ) |
| 361 | M8.3. Supplying, laying and connecting 50 x 6 mm. GI Flat laid in open fashion with necessary clamps,screws, interlinks etc for inter connecting, Typical floor, DG set & power Panel of the earth pits |
| 362 | M8.4. Supplying, laying and connecting 25x 6 mm. Cu Flat laid in open fashion with necessary clamps,screws, interlinks etc for Neutral Earthing of DG Sets |
| 363 | M8.5. Supplying, laying and connecting 25 x 6 mm. GI Flat laid in open fashion with necessary clamps,screws, interlinks etc for Body Earthing of Sub Panels Etc., |
| 364 | M8.6. Supplying, laying and connecting 25 x 3 mm. GI Flat laid in open fashion with necessary clamps,screws, interlinks etc for Body Earthing of Lift Etc., |
| 365 | M8.7. Supplying, laying and connecting 8SWG GI wire laid in open fashion with necessary clamps,screws, interlinks etc for earthing of All DBs ,Fans & AC Equipments |
| 366 | M8.8. Supplying, laying and connecting 25 x 6 mm. 300mm Cu Flat AS EARTH LINK with necessary holes, complete set |
| 367 | M8.9. Supplying, laying and connecting 50 x 6 mm. 500mm GI Flat AS EARTH LINK with necessary holes, complete set |
| 368 | M8.10 . Supplying, laying and connecting 25 x 6 mm. 400mm GI Flat AS EARTH LINK with necessary holes, complete set |
| 369 | M8.11. Supplying, laying and connecting 25 x 3 mm. 400mm GI Flat AS EARTH LINK with necessary holes, complete set M9.CABLE TRAY Supplying,erecting & connecting and commissioning Cable Trays of following measurements with necessary Box Channel for cable supports and other allied fabrication works. Fixing to concrete surfaces shall be done with the help of expandable type anchor fastners capable of bearing a weight of 500 Kgs. Fixing to brick walls shall be done by grouting. The distance between two supports shall be 2000 mm. The materials and labour for grouting, cable supports and other allied fabrication work shall supplied by the Contractor. The price includes all support for cable tray and allied fabrication works..etc complete along with necessary earthing of the cable tray with necessary 2R 25x 3mm GI Strip run along with cable tray. The price inclusive of GI strip and other accessories. |
| 370 | M9.1. 450 x 50 x 1.6mm perforated Type Cable tray with 2R 25x 6mm GI Strip |
| 371 | M9.2. 150 x 50 x 1.6mm perforated Type Cable tray with 2R 25x 3mm GI Strip M10. RAW POWER WIRING |
| 372 | M10.1. Supplying, wiring, connecting & commissioning the Light Points with 2 Runs of 4 + 1R 2.5 Sqmm. PVC Insulated multistranded copper conductor FRLS wires (one each for Phase, Neutral and earth) in heavy duty 25mm MS Conduits in wall / Ceiling partitions or laid in open fashion above false ceiling with necessary clamps, screws, etc., |
| 373 | M10.2. Supplying, wiring, connecting & commissioning the Light Points with 3 core 4 sq.mm PVC Insulated multistranded copper conductor cable in heavy duty 32mm MS Conduits in wall / Ceiling partitions or laid in open fashion above false ceiling with necessary clamps, screws, etc., |
| 374 | M10.3. Supplying, and fixing 6/16 AMPS Switched Socket combined in 1.6 mm. thick in Manufacturer's mounting box fixed flush with the wall. |
| 375 | M10.4. Supplying, and fixing 6 AMPS Switched Socket combined in 1.6 mm. thick in Manufacturer's mounting box fixed flush with the wall. |
| 376 | M10.5. Supplying, and fixing 25 AMPS Switched Socket combined in 1.6 mm. thick in Manufacturer's mounting box fixed flush with the wall. (Ev charging) M11.LIGHT POINT WIRING Mains Wirng (DB to Switch Board)(MCB in LDB to first point) |
| 377 | M11.1Supplying, wiring, connecting & commissioning the Light Points with2 Runs of 2.5 + 1R 1.5 Sqmm. PVC Insulated multistranded FRLS copper conductor/FRLS wires (one each for Phase, Neutral and earth) in already laid PVC Heavy duty Conduits laid in open fashion in wall / in ceiling with necessary clamps, screws, etc., MCB in the LDB to First light point |
| 378 | M12.POINT WIRING Average length (first point to Second Point -3M to 5M, in MCB controlled light) Supplying, wiring, connecting & commissioning the Light Points with 3 Runs of 1.5 Sqmm. PVC Insulated multistranded copper conductor FRLS wires (one each for Phase, Neutral and earth) in already laid 25/20mm heavy duty PVC Conduits in wall / ceiling with necessary clamps, screws, GI Flexible Hose, etc., including supplying and fixing 6 AMPS Switch in Manufacturer's mounting box fixed flush with the wall |
| 379 | M12.1. One Light Controlled by one Switch. |
| 380 | M12.2. Two Light Controlled by one Switch. |
| 381 | M12.3. Three Light Controlled by one Switch. |
| 382 | M12.4. Four Light Controlled by one Switch. |
| 383 | M12.5. Five Light Controlled by one Switch. |
| 384 | M12.6. Six Light Controlled by one Switch. |
| 385 | M12.7. Seven Light Controlled by one Switch. |
| 386 | M12.8. Four Light Controlled by one MCB |
| 387 | M12.9. Five Light Controlled by one MCB |
| 388 | M12.10. Six Light Controlled by one MCB |
| 389 | M12.11. Staircase Light one light Controlled by 2 way one Switch M13.CEIG APPROVAL |
| 390 | M13.1. Preparation of TNEB Drawings, submission, getting drawing approval, arranging inspection, attending the defects with regard to electrical, getting safety certificate etc., The job includes submission of as built drawings. The contractor should submit 5set. It is the sole responsibilty of the contractor to get the required sanctions & approvals from the CEIG & to submit the same to the Employer in the allocated timeframe. |
| 391 | M13.2.Preparation of TNEB Drawings, submission, getting drawing approval, arranging inspection, attending the defects with regard to electrical, getting safety certificate for DG SETS etc., The job includes submission of as built drawings. The contractor should submit 5set. It is the sole responsibilty of the contractor to get the required sanctions & approvals from the CEIG Safety certificate for DG SETS & to submit the same to the Employer in the allocated timeframe. M14.LIGHT FIXTURES Supply Installation testing and commissioning of light fixtures |
| 392 | M14.1. 28W 4feet LED light |
| 393 | M14.2. 15W LED Ceiling light |
| 394 | M14.3. 15w Wall light |
| 395 | M14.4. Bulk Head light with 9W Led Bulb |
| 396 | M14.5. Mirror Light |
| 397 | M14.6 Supply & Installation of Standard commercial roadway lighting poles of 4.0mtr height with control box, loop in loop out connectors, SP MCB , single straight arm luminaire fixing bracket of 1.5mtrs length , Pole earthing with 8SWG GI wire, interconnection between control box luminaire with 3cx1.5sq.mm copper PVC sheathed cable, necessary M.S base work for pole, 40mm GI Sleeves for cable in / out, excavation, concreting, coping etc., complete including required civil & fabrication works. Also including one-coat of red-oxide & two coat of approved enamel paint. As approved by Project Manager. Light Fitting Shall be of LED Type. Excluding LED light fixture |
| 398 | M14.7 LED Street Light -50W |
| 399 | M14.8. Ceiling fan |
| 400 | M14.9. Exhaust fan M15. UPS |
| 401 | M15.1.Supply & Erection testing and commissioning of 5 kVA UPS of following specification with 15 mins battery backup, complete set. M16.INVERTER |
| 402 | M16.1.Supply & Erection testing and commissioning of 5 kVA Inverter of following specification with 90 mins battery backup, complete set. M17.PVC CONDUIT / PIPE Supply and laying of heavy duty PVC conduit concealed in wall/floors/ceilings with necessary clamps, screw with 1 Run of 16SWG G.I. Fish wire Finishing of concealed pipes ( in side the wall) by chicken mesh, etc., complete set. |
| 403 | M17.1. 20mm heavy duty PVC Conduit for Telephone/Data |
| 404 | M17.2. 450mm heavy duty RCC hume pipe NP2 for power cable including 3 feet sand excavation & re filling. ( EB Cable ) |
| 405 | M17.3. 300mm heavy duty RCC hume pipe NP2 for power cable including 3 feet sand excavation & re filling. ( EB Cable ) |
| 406 | M17.4 150mm heavy duty RCC hume pipe NP2 for power cable including 3 feet sand excavation & re filling. ( DG/Networking ) |
| 407 | M17.5. 32mm hdpe pipe for external work M18.LIGHTNING PROTECTION Design & Supply of Air Termination |
| 408 | M18.1. Supply, design and testing of Early Streamer Emission (ESE) lightning conductor. Equipped with Stainless central pick up rod. Full electrical continuity between the tip and the earth point. Fully autonomous (no battery, no external power supply required). Collect energy through streamer emission controlled with detects the lightning and trigger a streamer (3,5KV and 20A). Manufactured as per CPRI Requirements Rating for which tested 5+ve and 5-ve lightning impulse current (8/20ms) of 70KA temperature in degree celsius 25 degree, atmosphere Pressure in mm of Hg680, relatire humidity rh%77 & Indian standard. Radius52mtr at LEVEL-4 M19. Supporting Pole & stay arrangement |
| 409 | M19.1. Supply of 5 mtr elevation pole made of GI with a dia of 40mm with a M20 thread at the top to fix the unit. Supplied with Bracket, clamps and all required fixing equipments. M20.Supply of Down Conductor |
| 410 | M20.1. Supply of 50mm² insulated copper cable. As a down conductor |
| 411 | M20.2. Supply of Lightning flash counter M21. SAFETY EQUIPMENTS |
| 412 | M21.1. Supplying, erecting and connecting Treatment Chart in English and Local Language directly fixed on to the wall with necessary screws etc. |
| 413 | M21.2. Supplying 440 V Gloves |
| 414 | M21.3. Supplying, and laying 2000 mm. x 1000 mm x 3 mm. thick ISI Marked Rubber mats to be laid in Front of the Panel Boards. |
| 415 | M21.4. First Aid Box |
| 416 | M21.5. Supplying and fixing 440 V Danger Board. M22. CONSTRUCTION LIGHTING |
| 417 | M22.1. Supply of Construction Lighting accessories such as Light fittings, Cables , Switches, & Sockets etc complete with all accessories |
| 418 | 2.0 N-DG SET |
| 419 | N1.275kVA DG SET |
| 420 | N1.1.220 KW/275 KVA Prime Power Rated Radiator cooled Type Diesel generating Set 415 V, Mounted on a Channel Iron Base Frame, Residential SilencersFlexible Bellows First Fill of Lube Oil, Radiator Coolant, BatteriesSet of Foot Mounted AVM Pads Engine Controller Radiator Control Panel along with Acoustic Enclosure for outdoor application along with built in fuel tank etc., |
| 421 | N2.DG SET ACCESSORIES |
| 422 | N2.1..Unloading and Positioning of the DG Set and its allied accessories in the prepared foundation. |
| 423 | N2.2.6\\" MS Class B Exhaust Pipe Line for 275KVA from turbo to silencer inlet |
| 424 | N2.3.8\\" MS Class B Exhaust Pipe Line for 275KVA from Silencer to Verticle height |
| 425 | N2.4.Exhaust Pipe bends |
| 426 | N2.5.\\"Y\\" Joint after Silencer |
| 427 | N2.6.Thermal Insulation 50mm thick Mineral Wool and Cladding for Residential Silencer |
| 428 | N2.7.Thermal Insulation 50mm thick Mineral Wool and Cladding of 8\\" MS Pipe Line for 275KVA |
| 429 | N2.8.SS exhaust bellow after silencer |
| 430 | N3.1.CONTROL WIRING |
| 431 | N3.1.1.Supply laying and jointing of control cables between DG set , Power Panel ( Distance between DG Set & power Panel will be around 30 Mtrs.) Vendor has to provide test certificate, drawings and approval from pollution control board or any other Govt. departments. (Excluding safety certificate from CEIG for safe installation of above DG set) Civil works such as plat form for DG set shall be done by the client All the panels should be compatible with BMS Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 25 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender