Tender For Construction Of 2 Nos Permanent Courts At Second Floor Of Judicial Block In Jcc At Baba Bakala Sahib Distt: Amritsar (Punjab)

Issued by Government Departments · Amritsar, Punjab
Tender Value
8.22 Crore
Estimated cost
Bid Submission
25 Aug 2026
13 days left
EMD
16.44 Lakhs
Bank guarantee accepted
Document Fee
30000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Amritsar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of 2 Nos Permanent Courts At Second Floor Of Judicial Block In Jcc At Baba Bakala Sahib Distt: Amritsar (Punjab)

BOQ

Name of Work:- CONSTRUCTION OF 2 Nos PERMANENT COURTS AT SECOND FLOOR OF JUDICIAL BLOCK IN JCC AT BABA BAKALA SAHIB DISTT: AMRITSAR (PUNJAB)
Sl. No. Item Description
1CIVIL WORK
2Construction of 2 Nos Courts at Second Floor of Judicial Block
3Dismantling concrete
4Reinforced cement concrete
5Cement concrete plain 1:3:6 mix
6Dismantling cement conglomerate floors 25mm to 50mm thick without concrete base
7Scraping Cement plaster
8Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled.
9Doors of area 3 sqm and below.
10Windows of area 3 sqm and below
11Dismantling brick work tile, masonry or tile liningIn cement
12Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
13Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
14Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
15Shelves
16Total all Floor
17Extra rate for Second Floor
18Lintels
19Extra rate for First Floor
20Extra rate for Second Floor
21Extra rate for Third Floor
22Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
23Beams
24Total all floor
25Extra rate for First Floor
26Extra rate for Second Floor
27Extra rate for Third Floor
28Columns (Rectangular & Square)
29Total all Floor
30Extra rate for First Floor
31Extra rate for Second Floor
32Extra rate for Third Floor
33Lift Walls
34Total all floor
35Extra rate for Second Floor
36Extra rate for Third Floor
37Total qty for all floor
38Extra rate for First Floor
39Extra rate for Second Floor
40Extra rate for Third Floor
41Cement concrete 1:3:6 with stone ballast or shingle 40 mm guage. using concrete mixing volumetric type
42Extra rate for Third Floor
43Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
44Total qty for all floor
45Extra rate for First Floor
46Extra rate for Second Floor
47Extra rate for Third Floor
48Centring and shuttering for Columns ( Square or Rectangular or ply gonal in plain)
49Total qty for all floor
50Extra rate for First Floor
51Extra rate for Second Floor
52Extra rate for Third Floor
53Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
54Total qty for all floor
55Extra rate for First Floor
56Extra rate for Second Floor
57Extra rate for Third Floor
58Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or bartering including attached pillasters buttersses etc
59Second Floor
60Extra rate for Second Floor
61Third Floor
62Extra rate for Third Floor
63Centring and shuttering for stair cases with sloping with soffits including risers and stringers.
64Total qty for all floor
65Extra rate for Second Floor
66First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level..
67Total qty for all floor
68Extra rate for First Floor
69Extra rate for Second Floor
70Extra rate for Third Floor
71Extra rate for Fourth Floor
72Providing and laying in super structure for first storey factory made with vibro-hydraulic compaction machine precast hollow block of cement concrete 100 mm thick setting in position with cement mortar 1:3 (1cement:3 course sand ) including cost of hosting, centering and shuttering complete as per IS:2185 (Part-1): 2005..
73Second Floor
74Extra rate for Second Floor
75Providing and laying in super structure for first storey factory made with vibro-hydraulic compaction machine precast Hollow block of cement concrete setting in position with cement mortar 1:3 (1 cement:3 course sand ) including cost of hosting, centering and shuttering complete as per IS:2185 (Part-1): 2005.
76Extra rate for Second Floor
77115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure.
78Extra rate for Second Floor
7912.5mm thick cement plaster 1:5.
80Total all floor
81Extra rate for First Floor
82Extra rate for Second Floor
83Extra rate for Third Floor
8420 mm thick cement plaster 1:5 in two coats work.
85Extra rate for First Floor
86Extra rate for Second Floor
87Extra rate for Third Floor
8812.5 mm thick cement plaster 1:4.
89Total all floor
90Extra rate for Second Floor
91Extra rate for Third Floor
9220 mm thick cement plaster 1:4.
93Extra rate for Second Floor
94Extra rate for Third Floor
95Providing precast cement concrete Jali 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3 (1 cement: 3 fine sand) etc. complete excluding plastering of the jambs, sills and soffits.50 mm thick
96Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp
97U-PVC pipes (working pressure 4 kgf. / sqcm) pipe 110 mm dia.
98Providing and fixing U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
99UPVC 110 mm Coupling /Sockets
100Providing and fixing SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
101UPVC 110 mm Coupling /Sockets
102Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
103Bottom Khurra on ground 1.2m x 0.6m Mtr. Consisting of brick on edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5mm thick cement plaster 1:3.
104Providing and fixing in position gratings 150mm x 150mm for gully trap.PVC grating
105Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
106Extra rate for Second Floor
107Extra rate for Third Floor
108Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
109Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material
110Total all Floors
111Extra rate for Second Floor
112Extra rate for Third Floor
113Conglomerate floor 40mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).
114Second Floor
115Extra rate for Second Floor
116Providing and laying Laminate wooden flooring (Grade AC3 or AC3+ laminates) 6 mm to 12 mm thick, having core made up of medium-density fiberboard (MDF),which is less resistant to impact damage and less resistant to being dented by heavy furniture, having a décor layer to give each floor its appearance and consisting of one or more sheets of paper impregnated with melamine resin and top wear layer having clear aluminum oxide finish that protects the decorative layer & imparts the desired level of sheen, from full gloss to low gloss, duly fixed to the base floor using adhesive as approved by the manufacturer.
117Second Floor
118Providing & Fixing PVC panneling tounged and grooved having 'U' for bottom, 'L'for vertical sides ,PVC designed moulding on Top fixing by means of PVC gatties and screws as per shade approved by the engineer-in-charge complete as per drawing.
119Marble stone flooring with 12-15 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with :Udaipur Green Marble Tiles of thickness 12mm to 15mmSlabs sizes above 0.50 sqm
120Total All Floors
121Extra rate for Second Floor
122Extra rate for Third Floor
123Marble work of thickness 12-15 mm for wall lining (veneer work), backing filled with a grout of average 12 mm thick in cement mortar 1:3 (1 cement : 3 coarse sand), including pointing with white cement mortar 1:2 (1 white cement : 2 marble dust) with an admixture of pigment to match the marble shade (To be secured to the backing by means of cramps, which shall be paid for separately).Udaipur Green Marble Tiles of thickness 12mm to 15mmSlabs sizes above 0.50 Sqm
124Total all Floors
125Extra rate for Second Floor
126Extra rate for Third Floor
127Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
128Total all Floors
129Extra rate for Second Floor
130Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)
131Extra for marble stone flooring in treads of steps and risers using single length
132Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects.
133Providing and laying vitrified floor tiles in different sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles have pigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.)Size 600x600 mm
134Extra rate for Second Floor
135Grouting the joints of flooring tiles having joints of 3 mm width, using 2mm to 3 mm gap using spacers and later this gap to be filled with cement based grout ) with Cement base grout and matching pigments etc., complete, including filling / grouting and finishing complete as per direction of Engineer-in-chargeSize 600x600 mm.
136Providing and Laying Out Door Precast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.
137Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)
138Extra rate for Second Floor
139Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps..
140Extra rate for Second Floor
141Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects.
142Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete
143I.S.I Designation No. III (size of door 851mm to 1000mm)
144Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973,Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-
14535mm thick
146Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm
147Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
148300mm x 16mm
149250mmx16mm
150PProviding & fixing factory made Solid PVC Chowkhat Door frame of the size 50mm x 47mm with a wall thickness of 5mm made out of extruded 5mm PVC foam sheet, mitre cut at 2 corners & joined with 2Nos of 150mm long brackets of 15 x 15mm M.S square tube. the two vertical doors profiles are to be reinforced with 19 x 19mm M.S square tube of 19 guage, the door framed shall be fixed to the wall using 65/100mm long M.S screws through the frame by using fasteners. a minimum of 4 nos of screws to be provided for each vertical member & minimum 2nos for horizontal member etc. as per manufacturer's specification,conforming to test criteria specified in IS:4020-1998, Drawings and to the entire satisfaction of engineer-in-charge.
151Providing & fixing 30mm thick Factory Made solid Panel PVC Door shutter (Pannel thickness 5mm) Consisting of frame made out of M.S tubes of 19 guage thickness and size of 19mm x 19mm for styles & 15mm x 15mm for top & bottom rails. M.S frame shall have a coat of steel primers of approved make & manufacture. M.S frame shall be covered with 5mm thick heat moulded PVC 'C' Channel of size 30 x 50mm forming styles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panneling of 5mm thick PVC sheet to be fitted in the M.S Frame welded/Sealed to the styles & Rails with 30mm wide x 5mm thick PVC sheet beading on either side and joined together with solvent cement adhesive.an additional 5mm thick PVC strips of 20mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent cement adhesive etc. complete as per manufacturer's specification, conforming to test criteria specified in IS:4020-1998,Drawings and to the entire satisfaction of engineer-in-charge.
152Supply & Fixing of door frames (Chowkhats) consisting frame fabricated from sheet roll formed out of 1.2mm thick galvanized sheet as per IS:277 (base steel as per IS:513) with zinc of 120gm/sqm & Powder coated with pure Polyster powder upto 50 micrones (as per approved colour) , 3 Nos 100mm but hinges 2mm thick, 6 Nos 1.2mm thick CRCA electroplated stiffner, 6 Nos M.S hold fast with split and tail welded to stiffner plate 200mm long, Receiver for aldrop, M.S tie rod 50mm x 25mm to be fixed at bottom finished with powder coated total thickness of coating 0.60mm of approved shade, fixed in position, including the cost of cement concrete for 1:2:4 for fixing lugs complete in all respects as per drawing, design, specification & entire stasfication of Enginner-in-Charge.
153Doors frame of size 80mm x 50mm with 37 mm wide single rebate for 35mm door shutter .
154Supply & Fixing of Window frames (Chowkhats) including mullions consisiting frame fabricated from sheet roll formed out of 0.58mm thick galvanished sheet (base steele as per IS : 513) with zinc of 120gm/sqm steel sheet pre coated (as per approved colour) with polyster paint of 12-16 micrones thickness under coat of EPOXY primer & back coated with ALKYD backer of 5-7 micrones total thickness of coating 0.58mm of approved shade, fixed in position by means of PVC & metal hold fastner with PVC cap complete in all respects as per drawing, design, specification & entire stasfication of Engineer-in-Charge.
155Windows Outer frame of size 72mm x55mm and central mullion 72 mm x 50mm with Double rebate.
156Supply & Fixing of Window shutter consisiting frame fabricated from sheet roll formed out of 0.58mm thick galvanished sheet (base steele as per IS : 513) with zinc of 120gm/sqm steel sheet pre coated (as per approved colour) with polyster paint of 12-16 micrones thickness under coat of EPOXY primer & back coated with ALKYD backer of 5-7 micrones total thickness of coating 0.58mm of approved shade, fixed in position by means of screws, complete in all respects as per drawing, design, specification & entire stasfication of Engineer-in-Charge.
157Glazed Windows shutter Section 47mm x 20mm (Without Glass)
158Wire Mesh Windows shutter Section 40mm X 20mm with S.S wire mesh 32 gauge flymesh with 144 holes per square inch
159Providing and fixing glazing in door, window, ventilator shutters and partitions etc, complete as per the architectural drawings and the directions of engineer-in-Charge (Cost of gasket/beading shall be paid as per respective item)
160Float glass panes of 5mm thickness
161Providing & fixing fixed beeding 12mm X 12mm for fixed glass with Eco fixed gasket (EPDM)
162Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
163Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) :
164For fixed portion & Chaukhat
165For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required
166Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge.4mm thick ACP Sheet
167Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item)Float glass panes of 5 mm thickness
168Providing Polyester Powder coating 50 micron any coloured specified to alumnum section of various sizes including carriage of material from market to workshop & workshop to site of work.
169Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
170Total Qty for All Floor
171Extra rate for First Floor
172Extra rate for Second Floor
173Extra rate for Third Floor
174Providing and fixing factory made ISI marked un-insulated metal fire rated doorset assembly for all egress applications areas like utility rooms and service areas consisting of galvanized iron steel frame and double leaf shutter including necessary hardware accessories, conforming to FD 120 UD classification of IS 3614:2021 with fire rating of 120 minutes integrity. The door frame and shutter shall be made out of minimum 1.20 mm thick GI Sheet with minimum 120 GSM Zinc coating as per IS: 277. The entire fire rated doorset assembly shall be tested in unlatched condition as per IS 17518 (Part- 1): 2022Frame:The frame shall be of minimum size 90 x 60 mm with grooved profile to take appropriate fire rated smoke seal, having mitred cut joints (self tab/screwed assembled at site) and provided with appropriate reinforcement suitable for taking hardware and flush fixing as per IS: 4351. The smoke seal material shall be of EPDM tested in accordance with ASTM E- 84 of minimum size 10×4 mm, fixed within the inbuilt groove or stuck with adhesive on the entire perimeter of the frame. The door frame shall be fixed in all three sides to masonry wall opening with CSK/Hex headed fasteners of minimum 8 mm dia size and minimum 80 mm long with 8mm dia polyamide sleeves @ 5 numbers at each on vertical side and 3 numbers on top side.Door shutter: The double skin double leaf door shutter shall be consisting of minimum 46 mm thick and having box like structure, slots cut and holes punched for fixing of hardware with stiffener as per IS 16074 including Resin bonded honey comb paper core infill material of density 5 kg/cum. Each door leaf shall be provided with vision panel, having maximum area of 0.12 sqm, of 120 minute fire rated minimum 6 mm thick clear borosilicate glass pane fixed with clip-on arrangement and fire rated ceramic tape having minimum size 13x2mm to be fixed all around the glass on both the sides. Integral astragals to be provided for double leaf doors on the meeting style each on both active and inactive leaf. The door shutters shall be mounted on the frame with SS 304 grade ball bearing butt hinges as per EN 1935: 2002 or butt hinges as per IS 12817 both, of minimum size 100x75x3 mm @ 5 numbers hinges per door leaf upto 2400 mm height or as per test evidence, which ever is more, fixed with M6 25 screws. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hardware accessories.
175Hardware Accessories:Fire doorset shall provided with one number fire rated SS 304 grade Mortise dead lock, 50-80 mm Back Set, minimum 20 mm Square forend with allen key Escutcheon of Stainless Steel, and 65/70 mm cylinder with both side key conforming to IS: 16015:2022/EN12209, two pair of D type Pull handle of SS 304 grade of minimum 22 mm dia Centre to centre distance of 300 mm back to back fixing with spindle, one number 300 mm long Concealed lever action flush bolt (Dye-Cast Stainless Steel Finish) at bottom with SS dust proof socket and one number 600 mm long Concealed lever action flush bolt (Dye-Cast Stainless Steel Finish) on top of inactive leaf of double door. Two number fire rated surface mounted heavy duty door closer of size EN 3-5 with standard arm, of desired finish conforming to IS 3564/EN 1154..Finishing:Both frame and door shutters shall be factory finished with polyester powder coating of minimum 50 microns thick and shall have passed salt spray test as per IS:13871 of approved colour and shade all complete as per manufacturer’s specifications and as per direction of the Engineer-in-charge.Installation:The hollow space in the door frame shall be filled / injected with fire rated self extinguishing type polyurethane foam (PUF) after installation at site of work. The rate shall be inclusive of complete fire rated door assembly, supply and installation by the approved manufacturer.
176Double leaf un-insulated metal fire rated doorset of FD 120 UD classification with 120 minutes integrity only as per IS 3614:2021-For egress application like utility room and service area etc.
177Supplying and filling cinder on roof (Ist story) including light ramming
178Providing & Fixing DIAS consisting of teak wood frame work ,20mm thick water proof teak ply board, 12 mm thick water proof ply, finished with polishing painting as per shade approved by the engineer-in-charge,handles, hinges, locks complete as per drawing.
179Providing and Fixing of Copper Sheet 16 Gauge 350mm wide on expansion joint including covering with C. Concrete complete in all respect as per specifications.
180Providing and fixing covering 200mm wide Aluminium Sheet 14 Gauge with gatties and screw on vertical expansion joints one side fixed and one side fixed with slotted holes to allow movement complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.
181Preformed fillers for expansion joints in concrete pavement and structures (non-extruding and resilient type) part-3 Polymer Based (CED 13: building construction practices including painting, varnishing and allied finishing) complete as per IS 1838-3 (2011):
182Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
183With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm
184Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge.
185Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
186Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
187Applying priming coat with metal primer on new steel or iron work including preparation of surface.
188Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
189Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping et
190Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
191Finishing walls with textured exterior paint of required shade with two or more coats applied @ 3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
192Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
193Disposal of Malba ouitside the premises including loading and unloading as desired by Engineer in charge.
194Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S.clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
195Credit of Old Material to be received
196Tile from dismenling of tile terracing
197Bricks from dismenling of Brick work
198Brick/Tile bats
199Old Doors Complete set as fuel wood
200Old Doors Complete set as fuel Window
201Construction of Sub Station cum Electrical Panel Room
202Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
203Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
204Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
205First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth.
206First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level..
207Total qty for all floor
208Extra rate for First Floor
209115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure.
210Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
211Column
212Beams
213Lintels
214Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
215Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
216Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
217Centring and shuttering for columns (Square or rectangular or poly gonal in plain)
218Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS ClampU-PVC pipes (working pressure 4kgf. / sqcm)pipe 110 mm dia.
219Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm bend
220Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
221Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
222Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.
223Providing and fixing in position gratings 150mm x 150mm on top Khura PVC grating
224Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling onanother layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
225Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
226Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% taken only from outside the premises laying in plinth in 15 cm layers including ramming, watering and consolidating including all leads.
227Earth filling :--Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto 40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres
22812.5mm thick cement plaster 1:5.
22920 mm thick cement plaster 1:5 in two coats work.
23012.5 mm thick cement plaster 1:4.
231Total all floors
232Extra rate for First Floor
23320mm thick cement plaster 1:4 in two coat work.
234Extra rate for First Floor
235Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
236Kotah stone tile 20mm thick in skirting, riser of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 Cement and 3 Sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone including rubbing and polishing
237Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete
238Doors and windows frame of size 113mm x 60mm with 35 mm wide single rebate weighing 3.38 kg per meter.
239Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
240Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flash-welded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items)
241Wire gauge fixed on steel windows of standard rolled steel section, with 3mm thick flat iron cover moulding of 12.5mm width, fixed with machine screws, complete in all respects.
242Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.
243Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area
244Extra for providing & fixing Steel Tube beading size 12mm x 12mm, 18 guage of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal slash putty in steel doors, windows & Ventilators complete in all respect
245Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
246Supplying and fixing rolling shutters, of approved make, made of 80mmx1.25mm, M.S. Laths, interlocked together through their entire length and jointed together, at the end, by end locks, mounted on specially designed pipe shaft, with brackets, side guides, 27.5cm long wire spring grade No. 2 and arrangement for inside and outside locking with push and pull operation complete, including top cover 0.80mm thick (payment is to be made for the exact size of opening where rolling shutter is to be fixed)
247Providing and fixing ball bearing for push and pull type rolling shutters, from 9.20 to 12 sqm area
248Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973,Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-35mm thick
249Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm
250Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300mm x 16mm
251Conglomerate floor 50mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).
252Iron grated doors, including pintle hinges and arrangements. (For Cable Duct Covering)
253Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
254Extra rate for using steel produced in integrated plant from original ores complete in all respect as per the directions of Engineer-in-charge.
255Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
256Distempering with Acrylic washable oil bound distemper (of approved manufacture) two or more coats over one priming coat to give an even shade
257Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
258Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
259Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
260Applying priming coat with metal primer on new steel or iron work including preparation of surface.
261Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
262Construction of Plinth protection complete as per drawing.
263Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres.
264Cement Concrete 1:8:16 with 40mm guage stone aggregate using concrete mixing volumetric type
265First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
266Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material
267Conglomerate floor 50mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).
26812.5 mm thick cement plaster 1:5 complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge.
269Special repair of Ground Floor & First Floor JCC Block
270Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled.
271Doors of area 3 sqm and below.
272Windows of area 3 sqm and below
273Scraping White wash and colour wash
274Scraping Cement plaster
27512.5mm thick cement plaster 1:5.
276Extra rate for First Floor
277Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS Clamp
278U-PVC pipes (working pressure 4 kgf. / sqcm) pipe 110 mm dia.
279Providing and fixing U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
280UPVC 110 mm Coupling /Sockets
281Providing and fixing SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
282UPVC 110 mm Coupling /Sockets
283Factory manufactured flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-2191 Part-I) 1973,Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-35mm thick
284Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm
285Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :
286Providing and fixing hydraulic door closer ISI mark with necessary screw etc. completeI.S.I Designation No. 1 (size of door up to 700mm)
287Providing & Fixing PVC panneling tounged and grooved having 'U' for bottom, 'L'for vertical sides ,PVC designed moulding on Top fixing by means of PVC gatties and screws as per shade approved by the engineer-in-charge complete as per drawing.
288Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflection > 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking T-Grid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The system should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge.
289With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) size 595x595 mm
290Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete
291Doors and windows frame of size 113mm x 60mm with 35 mm wide single rebate weighing 3.38 kg per meter.
292Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter.
293Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flash-welded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items)
294Wire gauge fixed on steel windows of standard rolled steel section, with 3mm thick flat iron cover moulding of 12.5mm width, fixed with machine screws, complete in all respects.
295Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqmexceeding 0.4 sqm of area
296Extra for providing & fixing Steel Tube beading size 12mm x 12mm, 18 guage of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal slash putty in steel doors, windows & Ventilators complete in all respect
297Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
298Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to get required finish
299Applying priming coat with metal primer on new steel or iron work including preparation of surface.
300Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping et
301Painting two or more coats with synthetic enamel paints in all shades on old wood work or metallic or plastered or concrete surface to give an even shade including rubbing down old paint.
302Finishing walls with acrylic smooth exterior paint of required shade with two or more coats applied @ 1.67 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
303Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects.
304Providing and Laying Tactile Flooring full body vitrified , low water absorption below 5%, having excellent slip resistance , very dense, durable and abrasion resistant, solid through colour, fade proof, highly chemical and stain resistance unglazed finish porcelain tile of size 300mm x 300mm x 10mm + 5mm thick, approved profile design, Tec-button/Tec-liner laid in ordinary grey cement and on 20mm thick bed of cement mortar 1:3 filling neat cement slurry between joints with White Cement containing pigment to match the shade complete in all respect. (Tile design and pattern will be as per guidelines issued for persons with disability)
305Total all Floors
306Extra rate for First Floor
307Providing Information, Safety Sinage & Emergency Exit for Universal Accessibility
308Providing & fixing of Informatory sign board single legged double sided Size 600x600mm non glared with retro reflective high intensity Microprismatic grade sheeting type-iv as per ASTM D4956-09 fixed over 4mm thick ACP sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable epoxy base adhesive on back support frame of M.S hollow section 60x40x3.2 mm supported on a square M.S hollow steel section post 60x60x3.2mm conforming to IS code firmly fixed to ground in foundation concrete M-20 of size 0.45 x 0.45 x 0.60 M for vertical post complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India)
309Providing & fixing of Informatory sign board double sided hanging from ceiling Size 1371 x 952mm non glared with retro reflective high intensity Microprismatic grade sheeting type-iv as per ASTM D4956-09 fixed over 4mm thick ACP sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable epoxy base adhesive on back support frame of 40x20x3.2 Stainless Steel supported on a square M.S hollow steel section post 40x40x3.2mm conforming to IS code firmly hanged from ceiling/beam by fixing with expandable fastners complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India)
310Providing & fixing of Informatory sign board double sided hanging from ceiling Size 1371 x 634mm non glared with retro reflective high intensity Microprismatic grade sheeting type-iv as per ASTM D4956-09 fixed over 4mm thick ACP sheeting having aluminium skin thickness of 0.25 to 0.3 mm on both sided and fixing the same with suitable epoxy base adhesive on back support frame of 40x20x3.2 Stainless Steel supported on a square M.S hollow steel section post 40x40x3.2mm conforming to IS code firmly hanged from ceiling/beam by fixing with expandable fastners complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India)
311Providing & fixing of Single Side Signage with provision of Multilingual text integral with minimum 3.8mm thick blue/white or combine Acrylic base plate with upper case san serif words made of white acrylic non glare cut out letter of height not less than 20mm, raised above base plate by not less than 0.8mm and the equivalent workd/s written in Multilanguage i.e Regional, devnagri, English language as required with same specifications with Grade 1 Braille to be integral with the sign face and should be raised not less than 0.5mm above Acrylic base Plate complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India)
312Providing & fixing of 50 mm wide antiskid tape made of slip resistant material colour contrast, edge strip/tape 25mm to 50mm width self adhesive to be fixed on front edge of Stair treads to help people with visual disabliity and elderly even in dim light conditions & reduce the risk of slipping Make 3M or equivalent brand complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India)
313Providing & fixing of 50mm wide high intensitiy reflective, conspicuity tape colour contrast, self adhesive to be fixed on tread of stair case to help people with visual disabliity and elderly even in dim light conditions & reduce the risk of slipping Make 3M or equivalent brand complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India)
314Providing & fixing of Braille labels made of Stainless Steel (Grade-304) Size 170mm x 30mm x 4mm having Braille Dots raised 0.5mm above base plate complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India)
315Providing & fixing of Single sided Tactile Map consisting of visual information and acoustic information including Emergency Evacuation Layout with Provision of Multilingual text integral with minimum3.8mm thick blue/white or Combine Acrylic base plate with upper case san serif workds made of white acrylic non glare cut our letters of height not less than 0.8mm and the equivalent work/s writtenin Multilanguage i.e Regional, devnagri, English language as required with same specification with Grade 1 Braille to be integral with the sign face and should be raised not less than 0.5mm above Acrylic base Plate complete in all respects, as per specification & as desired by Engineer-in-Charge (Confirming to Harmonised guidelines & standards for Universal accessiblity in India-2021 issued by Ministry of Housing and Urban Affairs Government of India)
316Road marking with hot applied thermoplastic compound 2.5mm thick including reflectorising glass beads @ 0.25kg per sqm area as per IRC:35 1997 complete as per technical clause 803 of MORT&H specifications
317Providing & Installation of Furniture & furnishing of Courts such as Office Furniture etc
318Supply & Installation of SEAT/BACK ASSEMBLY: The Cushioned seat assembly consshould be ts of seat outer (material-30% Glass Fiber Nylon)& upholstered Seat inner (material- Poly Propylene) with moulded Polyurethane foam & polyster fabric. The Net Back should be made up of Back outer (material-Glass Fiber Filled Nylon)& Back inner (material- PP) and upholstered using Polyester Mesh fabric with high tenacity yarn.Full Back Size: 46.5 cm. (W) x 60.0 cm. (H)Seat Size : 51.0 cm. (W) x 49.0 cm. (D)HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR Polyurethane foam should be moulded with density = 45 +/- 2 kg/m³ and Hardness load 12 +/- 2 kgf for 25% compression. BACK SPINE: The support spine should be made up of High Pressure Die cast polished hed Aluminum. ARMRESTS : The armrest should be having two adjustment, Height (6.0±0.5cm) and Depth (6.0±0.5cm). Height adjustment should be provided in Aluminum structure of armrest which should be connected to Aluminum Back spine and should be operated by button. The depth adjustment should be provided in pad which should be fixed to armrest structure. Armrest Top should be made up of PU molded over plastic inner.ACTIVE BIO-SYNCHRO mechanism: The adjustable tilting mechanism should be designed with the following features:• 360° revolving type• Front-pivot for tilt with feet resting on ground & continuous lumber support ensuring more comfort• Tilt tension adjustment can be operated in seating position• 5 position Tilt limiter giving option of variable tilt angle to the chair• Seat / back tilting ratio of 1:2• The mechanism housing should be made up of HPDC Aluminum & black powder coated (DFT 40 to 60 micron)SEAT DEPTH ADJUSTMENT: Seat depth adjustment should be integrated in the seat through a sliding mechanism. Seat depth adjustment range should be of 3.75±0.1 cmLUMBAR SUPPORT ASSEMBLY: The Lumbar support assembly should consist of lumbar spine (material-Glass Fiber Filled Nylon) which should be fixed to Aluminum Back spine. The Lumbar pad (material- Poly Propylene) should be fixed to lumbar spine through lumbar Pad support. Lumbar Support Assembly has height adjustment of 5.0±0.5cm.PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment has an adjustment stroke of 10.0 ± 0.3cm.PEDESTAL ASSEMBLY WITH CASTORS:The pedestal should be High Pressure Die cast polished Aluminum and fitted with 5 nos. twin wheel castors. The pedestal should be 65.0 ± 0.5cm. pitch-center dia.(75.0 ± 1.0cm. With castors.)Headrest :The neckrest assembly consshould be ts of upholstered Neckrest inner(material-PolyPropy
319Supply & Installation of Table top size 2350x2350x750mm Primary Work Surface Made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top Soft closing access flap with in-build power box are provided on work surface for wire management. Secondary Work Surface Made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. Modesty Panel Made of 25mm thick MDF one side pre-laminate board confirming to IS-14587:1998 with 0.4mm PVC membrane pressed on to top. Under structure Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping.Integrated Pedestal Made of 25mm Thick Pre-laminated twin board of E1-P2 grade and approved shade. confirming to IS-12823:1990, Edge banded with matching 2 mm thick PVC lipping.Drawer fronts made of 25mm thick MDF one side pre-laminate board confirming toIS-14587:1998 with 0.4mm PVC membrane pressed on to topPedestal construction is BOX-BOX-FILE type which Uses powder coated 400 MM long metalPanel Drawer Slides. Drawer extension is 325 MM.Drawers have a soft closing & anti slam mechanism.Handles are provided for ease of opening.Pedestals are provided with lock for security.This Product should be Certified by CII GREENPRO,UL GREENGUARD ,SCS INDOOR ADVANTAGE GOLD.
320Enterprise 1500 Table with CPU Hanger size shall be 1500 Width mm x 750 Depth mm x 728 Height mm . Top shall be 18 mm thick Pre laminated particle board all work surface edges shall be having duly sealed with 2 mm thick PVC edgebanding. Understructure Modesty Panel 18 mm thick Pre laminated particle board . The Rectangular frame shall be fabricated component in 1.2 mm thick CRCA , Finish : powder Coat( epoxy polyster) . Leg shall be fabricated component in 38 mm x 25 mm 1.2 mm thick MS ERW ATube ,finish powder coat ( epoxy polyster).The plastic cap for cable travel shall be injection moulded polypropylene and leveler glide for shall be nylon 6 & MS bolt. The storage shall be having shell and drawer tray 0.6 mm thick CRCA Finish powder coat (epoxy polyster) plus the drawer front shall be 0.8 mm thick CRCA Finish powder coat (epoxy polyster) plus lock with 10 lever and handle and leveller. The wire management shall be horizontal wire carrier 0.7 mm thick CRCA Finish powder coat (epoxy polyster) and vertical wire carrier 0.8 mm thick CRCA Finish powder coat (epoxy polyster) .
321Supplying and Installation of Mid Back Chair. SEAT ASSEMBLY: The seat assembly should be made up of 1.2 ±0.1cm. thick hot-pressedplywood , upholstered with fabric upholstery covers and moulded Polyurethane foam.SEAT SIZE: 47.0 cm. (W) x 48.0 cm. (D).BACK ASSEMBLY: The back asembly. should be made of powder coated (OFT 40-60 microns) tubular frame of 0 2.54 ±0.03cm. x 0.2 ±0.016cm.thk. MS ERW tube designed with contoured lumbar support for extra comfort. The back should be upholstered using double layer spacer mesh fabric with high tenacity yarn. BACK SIZE : 46.5 cm (W) x 60.5 cm (H).HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam should be moulded with density =45+/-2 kg/m3 and hardness load 16 ± 2 kgf for 25% compression.ARMRESTS: The one-piece armrests should be injection moulded from black Co-polymer Polypropylene. CENTRE-TILT mechanism: The mechashould be m should be designed with the following features:• 360° revolving type.• 17° ±2° maximum tilt on pivot at centre • Upright position locking. • Tilt tension adjustment. .PNEUMATIC HEIGHT ADJUSTMENT: The pneumatic height adjustment has an adjustment stroke of 11.0 ±0.3cm.TELESCOPIC BELLOW ASSY: The bellow should be 3 piece telescopic type and injection moulded in Black Polypropylene.PEDESTAL ASSEMBLY: The pedestal should be injection moulded in black 33% glass-filled Nylon66 and fitted with 5 nos. twin wheel castors. The pedestal should be 66.3 ±0.5cm. pitch-center dia. (76.3 ±1.0cm with castors.)TWIN WHEEL CASTORS: The twin wheel castors should be injection moulded in black nylon.Overall Dimensions of ChairSeat Height - min 43.3 to max 54.3cm.Height - min 89.5 to max 100.5cm.Width & Depth of Chair as measured from pedestal - Width-76.3 cm and Depth-76.3 cm.This Product should be Certified by CII GREENPRO ,SCS INDOOR ADVANTAGE GOLD.
322Supplying & Placing executive table in completely knock down conditions with an overall size 1200mm X 600mm X 750mm that is to be assembled at site. The construction of the main table shall be free standing structure constructed with the help of minifix dowels and pins. The table top shall be made up of 25mm thick particle board with approved laminate and finish as per approved shade. The profile shall be in rectangle shape with front and back full round post form and other edges shall be sealed with 2mm thick thin strip of impermeable PVC that is cut to fit the size of board panel and duly pasted with the assistance of edge banding machine at 200 degree Celsius. A pullout keyboard trey shall be provided of 18mm thick Pre-laminated particle board having size 550mm X 280mm. The trey shall be operated on keyboard channel. The top shall be supported over particle board base gable end. The end wall of the table on the side shall be topped by gable end. It should be made up of 25mm thick particle board and profile shall be in linear shape with front and back full round post form and other edge with appropriate PVC edge banding. The table shall be clad with 18mm thick modesty panel which provide structural support for the table. It shall be 18mm thick particle board with appropriate PVC edge banding connected with both end. There shall be buffers provided at the base to avoid scratches on the floor. Mobile pedestal shall be provided with an overall size 400mm X 450mm X 650mm. The pedestal shall be made up of Pre-laminated particle board of grade II of IS 12823. Pedestal side, back, top, facia shall be 18mm thick and drawer base shall be 9mm thick. The pedestal shall have 3 nos. of drawer i.e. 2 box drawer and 1 filing drawer. The drawer shall be operated with handle and easily close & open with the assistance of roller channel and ball bearing channel to enable smooth operation. The drawer shall have central locking mechanism in which all the drawer shall be synchronized locked with one single key. The pedestal shall be mounted over 50mm injection moulded nylon castor. A movable type CPU unit shall be provided with an overall size 468mm X 284mm. The CPU unit shall be made up of 18mm thick Pre-laminated particle board and mounted on nylon castors.The board used should meet International Standard of quality, Indian standard IS 12823 grade II should meet long time load bending, screw-withdrawal strength, modulus of rupture and modulus of elasticity bending tested as per IS 2380.
323Providing, supplying and placing of Visitor Chair. SEAT ASSEMBLY: The seat assembly should be made up of 1.2 ±0.1cm. thick hot-pressed plywood , upholstered with fabric upholstery covers and moulded Polyurethane foam.SEAT SIZE: 47.0 cm. (W) x 48.0 cm. (D)BACK ASSEMBLY: The back asembly. should be made of powder coated (OFT 40-60 microns) tubular frame of 0 2.54 ±0.03cm. x 0.2 ±0.016cm.thk. MS ERW tube designed with contoured lumbar support for extra comfort. The back should be upholstered using double layer spacer mesh fabric with high tenacity yarn.BACK SIZE : 46.5 cm. (W) x 60.5cm. (H)HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR polyurethane foam should be moulded with density =45+/-2 kg/m3 and hardness load 16 ± 2 kgf for 25% compression.ARMRESTS: The one-piece armrests should be injection moulded from black Co-polymer Polypropylene. .TUBULAR FRAME: The powder coated (DFT 40-60.microns) tubular frame should be cantilever type & made of Ø2.54 ±0.03cm. x 0.2 ±0.016cm thick M.S.E.R.W. Tube. Overall Dimensions of ChairSeat Height - 46.5cm.Height - 93.5cm.Width & Depth of Chair as measured from pedestal - Width-61.0 cm and Depth-64.5 cm. This Product should be Certified by CII GREENPRO ,SCS INDOOR ADVANTAGE GOLD.
324Supplying & Placing three seater bench. The seat and back shall be made up of high quality cold rolled MS perforated sheet of 1.2mm thick, pressed and welded to form the shape. The seat and back electrostatically coated with epoxy powder and then cured under heat to allow it to form a skin. The armrest shall be made up of mild steel powder coated tube with 1.2mm thick. The base structure shall be supported by MS powder coated with 40-60µ (DFT). The OEM should have the quality certifications like Green Guard by UL, AIOTA, BIFMA mebership, 9001:2008, ISO 14001:2004 and ISO 18001:2007 issued by NABCB accreted Labs. There shall be PPCP shoe provided at the base to avoid scratches on the floor. The seat size shall be 440±10 mm(D) X 405±10 mm(H) from ground. Overall height shall be = 775±10 mm, overall depth = 710±10 mm & overall width = 1765±10 mm.
325Providing, supplying and placing steel almirah in perfectly upright and straight position. The overall size of the Almirah shall be 915mm (W) X 485mm (D) X 1980mm (H) including legs. It should be supplied with 4 nos. of adjustable shelves i.e. 5 loading compartments. Door shall be made of 1mm thick and all other components shall be made of 0.8mm thick high yield strength CRCA sheet of grade ‘D’ confirming to IS: 513. Stiffeners shall be provided in shelf & door. The steel hinged door shall be provided with locking mechanism which is assembled with bolt arrangement. The shelves shall have folded constructions which have intrinsic rigidity and high load carrying capacity. Uniformly distributed load capacity per each shelf shall be 40kg maximum. The complete steel structure shall be constructed by welding and provide finishing with epoxy polyester powder coated to be thickness 50-60µ.
326Providing and supplying centre table with an overall size 600mm X 600mm X 450mm. The top shall be made up of 18mm thick particle board. The edges shall be cladded by 1.2mm thick extruded aluminium section all around the top. The understructure shall consist of 4 nos. of legs made up of extruded aluminium section.
327Providing and supplying visitor chair with ergonomic design for user comfort. The seat shall be made of 9mm thick hot pressed plywood upholstered with high resilience polyurethane foam 25mm thick having density 40kg/m³ with leatherite tapestry 0.8mm thick and 535 GSM and the back shall be made of double layered moulded hot pressed plywood (6+9)mm thick upholstered with high resiliencepolyurethane foam 19mm thick having density 23kg/m³ with leatherite tapestry 0.8mm thick and 300 GSM. The seat and back shall be arrested together with MS/CRCA pipe frame and the armrest shall be used polypropylene arm mounted on pipe frame completely joint with seat and back. The frame structure shall be supported by four legs made up of MS/CRCA chrome plated round pipe of Dia.25.4mm with 1.6mm thick. There shall be co-polymer polypropylene shoe provided at the base to avoid scratches on the floor. The seat size shall be 450±10 mm(D) X 440±10 mm(W) and back size shall be 415±10 mm(W) X 405±10 mm(H) from seat. Overall height shall be = 835±10 mm.
328Supplying and Installation of the Main table shall be of size 1800 Width mm x 900 mm Depth x 750 mm height with side table 1200x445x660mm. Top surface of the table shall made up of MDF (Medium density fibre ) board duly finished with Veneer and final coating of PU. The Main desk should contain in built key board pull out tray for keeping keyboard of computer. The front modesty panel of the table shall be made up of MDF board of size 1640 mm x 600 mm x 16mm which shall also be duly finished with Veener and PU coating. For personal storage one mobile pedestal (3 drawer unit) shall be provided of size 510 mm Width x 635 mm Height and 445 mm Depth. The storage pedestal shall also be made up of MDF duly finished with veener & final coating of PU. The Side shall be of size 1200mm Width x 445mm Depth x 660 mm Height. The side unit shall be made up of MDF board duly finshed with Veneer and final finish by PU Coating. The design of the side unit shall be such that it can be placed on either side of the main table. The side unit shall contain open space for keeping cpu in extreme right side, one closed storage shutter at extreme left end & open space in the middle with one shelf for keeping files. The thickness of the top of the side unit shall be 25mm.
329Supplying and Installation of SEAT/BACK ASSEMBLY: The Cushioned seat assembly consshould be ts of seat outer (material-30% Glass Fiber Nylon)& upholstered Seat inner (material- Poly Propylene) with moulded Polyurethane foam & polyster fabric. The Net Back should be made up of Back outer (material-Glass Fiber Filled Nylon)& Back inner (material- PP) and upholstered using Polyester Mesh fabric with high tenacity yarn. Full Back Size: 46.5 cm. (W) x 60.0 cm. (H)Seat Size : 51.0 cm. (W) x 49.0 cm. (D)HIGH RESILIENCE (HR) POLYURETHANE FOAM: The HR Polyurethane foam should be moulded with density = 45 +/- 2 kg/m³ and Hardness load 12 +/- 2 kgf for 25% compression.BACK SPINE: The support spine should be made up of High Pressure Die cast polished hed Aluminum.LUMBAR SUPPORT ASSEMBLY: The Lumbar support assembly should consist of lumbar spine (material-Glass Fiber Filled Nylon) which should be fixed to Aluminum Back spine. The Lumbar pad (material- Poly Propylene) should be fixed to lumbar spine through lumbar Pad support. Lumbar Support Assembly has height adjustment of 5.0±0.5cmTUBULAR FRAME: The powder coated (DFT 40-60 micron) tubular frame should be cantilever type & made of ∅2.54±0.03 cm x 0.2±0.016 cm thk MS ERW tube.Overall Dimensions of ChairSeat Height - 48.5cm.Height - 99.5cm. Width-65.5 cm and Depth-58.2 cmThis Product should be Certified by CII GREENPRO,UL GREENGUARD GOLD,GRIHA,SCS INDOOR ADVANTAGE GOLD,BIFMA LEVEL 2.
330Supplying & Intallation of 2 str-width-132cm X depth- 88cm X height-91cm X seat height-45cm3 str-width-181cm X depth- 88cm X height-91cm X seat height-45cmFRAME MATERIAL (TROPICAL WOOD / PINE WOOD/ RUBBER WOOD): Pine WoodMoisture Content ( Recommended 12 – 18 %) : 12%Anti – Tremite Treatment (Recommended Borex Powder Treatment) : Treated Wood.Leg Material-* Fixing of Leg : (Self Tapping Screw / Insert with metric threading) :- Self Taping Screw.* Material of leg : (Plastic / Insert Moulding / Wooden/ MS + Chrome Plating / SS) :- WOODEN LEG.* Bush for Leg bottom : (PVC bush / Felt Pad) :- PVC Bush
331Supplying and Installation of Center table of Dimensions W x H x D (cm)-120 x 45 x 60Material : 18 mm thk prelaminated particle boardShade : Remini WalnutConstruction : Knock downFinish :1) MIP lamination in Remini Walnut shade withmatching lipping in Matt finish2) MIP lamination in Remini Black ink shade withmatching lipping in Matt finish
332Providing and supplying metal book case with an overall size 915 mm (W) X 320 mm (D) X 1750mm (H). The book case shall be supplied with 4 nos. of individual compartments. Top, back & side panels shall be made of 0.8mm and rest 1mm high yield strength CRCA sheet of grade ‘D’ confirming to IS: 513. Each door shall have individual locking provision and 4 mm thick transparent glass for clear inside vision secured in a metal frame through rubber gasket. Each door shall have scissor mechanism for receding inside the top of respective compartment which ensures parallel & smooth movement. Each door shall have plastic side end caps as handle which is easy to grip. Each compartment has a storage shelf having Uniformly Distributed Load Capacity of each shelf is 40 Kg maximum. The finish is Epoxy Polyester Powder coated to the thickness of 40-60µ. Adjustable leveler shall be provided with metal insert to resist scratches on the floor and also level & support structure.
333Outer infrastructure
334Construction of Internal Drive way / Pavements, Footpath Raised Pavement
335Construction of embankment with good quality earth obtained from borrow pits including compensation of earth, loading, unloading, carriage to site of work, spreading, grading to required slope and compacting to meet requirement of table 300-2 as per technical clause 305 of MORT&H specifications.
336Granular Sub Base Grade IConstruction of granular sub-base by providing material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as per MORD technical specifications
337Wet Mix MacadamProviding, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density complete as per technical clause 406 of MORT&H specifications
338Dismantling of PCC including T&P scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material. & staking the serviceable material with all lifts & lead of 100 mtr (By Mechanical Means)
339Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications
340Providing and laying 60 mm thick factory made cement concrete interlocking paver block of M-35 grade machine made rubber moulded smooth finish with strong vibratory process or with vibro- hydraulic compaction machine and of approved size and design / shape laid in Ordinary Grey and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge.IS COde : 15658 (2006)
341Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours.
342Providing and Laying Out Door Precast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurry containing pigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge.
343Precast Cement Concrete KerbProviding and laying factory made rubber moulded smooth finish cement concrete Kerb M-20 grade 250mm high with bottom width 165mm and top width 115mm made over strong vibratory table and fixing with cement mortar 1:2 as per MORT&H specifications
344Earth work in exavation in foundations, trenches, etc. in all kinds of soil where pick jumper work is not involved and not exeeding 2.0 Mtr. depth and subsequent filling around masonary in 15 cm layers with compaction including disposal of all surplus soil as directed within a lead of 30 Mtr. complete in all respect as per specifcation, drawing and to the entire satisfication of Engineer-In-Charge.
345Cement Concrete 1:8:16 with 40mm guage stone aggregate using concrete mixing volumetric type
346First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth.
347Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface
348Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
349Providing & Fixing of MS Grill Over Existing Boundary wall between office area and residence area
350Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
351Through wall 22.86 cm thick
352Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
35312.5 mm thick cement plaster 1:4.
354Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
355Applying priming coat with metal primer on new steel or iron work including preparation of surface.
356Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
357PUBLIC HEALTH SERVICES
358Sub Work-1
359Sub Head-1 Internal Sewerage System
360Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type B
361110mm o/d single socket SWR UPVC pipe lines laid complete
36290mm o/d single socket SWR UPVC pipe lines laid complete
363Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining.
364For 110mm o/d pipes
365Elbow 90 Degree (All side socketed)
366Vent Cowls
367Coupler
368Single Tee With Door
369Single Y-Junction
370Floor Trap 110mm x 75mm
371For 90mm o/d pipes
372Elbow 90 degree (all side socket)
373Vent Cowls
374Coupler
375Single Tee With Door
376Singel Y junction
377Providing and fixing in position SS Grating with frame of approved make (to the approval of engineer in charge) complete in all respects.
378Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge)
379110mm o/d
38090mm o/d
381Providing & Fixing in position M.S or heavy flat iron clamps made out of M.S flat iron not less than 5 mm of the approved design for fixing C.I. soil waste, vent or antisyhonage pipes to walls complete in all respects including cutting and making good the walls and floors etc. and painting.
382M.S. Holder bats clamps for 100mm i/d as per table-1
383M.S. Holder bats clamps for 75mm i/d as per table-1
384Cutting holes upto 23cm square for pipes in floor and roofs of cement concrete, reinforced concrete or reinforced brick work and making good the same & finishing according to existing finish where required.
385Through floor or roof 15.00cm thick
386Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm.
387100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mmas per table-1
388Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weightas per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design.
389450mm x 600mm inside with 455mm x 610mm cover and frame light duty double seal
390Sub Head-2 Internal Water Supply System
391CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in- Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge.
392SDR 11 CPVC pipes & fittings 20mm o/d
393SDR 11 CPVC pipes & fittings 25mm o/d
394Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes lines and making good the same to its original condition. Size 75mm x 75mm
395qty same as GI P 15mm i/d to 25 mm (Table-2)
396Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required.
397Through wall 11.43 cm thick Detail as per Table-2
398Through wall 22.86 cm thick Detail as per Table-2
399Providing, fixing and jointing Cpvc Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.
400Detail attached as per Table-2
40120mm i/d Cpvc Union
40225mm i/d Cpvc Union
403Providing, fixing and jointing ISI Marked Gun-Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.
40432mm i/d Gun Metal peet valve heavy pattern.
405Sub Head - 3 Sanitary Installation
406Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity. (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.
407Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity (without cistern fitting) size 62x37x67 cm with P trap or S trap and seat cover complete in all respect.
408Providing and fixing in position Chinaware extended wall mounted E. W.C. type suite (size 66 x 46 x 77.5 cm ) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) with or without 10 ltr. chinaware matching flushing cistern and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.Chinaware wall mounted E.W.C withoutcistern including seat cover complete inall respect.Detail attached as per Table-4
409Providing and fixing in position concealed cistern including flushing plate of approved make (to the approval of the Engineer-in-charge) complete in all respect.Detail attached as per Table-4
410Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect.
411Providing and fixing jet spray with 2'-6\\" long PVC pipe.With PTMT nut
412Providing and fixing Stainless steel health faucet complete in all respect.
413Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tubeconnection 300 mm long complete.
414Vitreous white Chinaware PartitionLarge partition size 75 x 16.5 x 36.5 cm
415Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) including Rack Bolt Screw Pair 115mm long without CP fittings complete in all respect.
416Size 560mm x 450mm (Under counter oval)
417Size 550 mm x 400 mm x 815 mm
418Providing and fixing in position C.P. Brass Auto close Pillar Cock of approved make (to the approval of Engineer-in-charge)Qty as per Inventory-3 & 4
419Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect.
420Size 550 mm x 400 mm x 815 mm
421Providing and fixing vitreous chinaware standard pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.
422Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect.
423Rectangular Sink with Deluxe Border Single Bowl Overall Size 555 mm x 475mm x 200 mm
424Double bowl Sink without drain board Overall size 1114 x 490 mm with bowl size 460x385x200mm including waste coupling
425Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect.
426Providing and fixing in position C.P. brass bottle trap 32mm dia with 40 mm seal of approved make (to the approval of Engineer-in-charge) complete in all respect.
427Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect.
428C.P. brass toilet paper holder
429Providing and fixing in position towel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect.
430C.P brass towel ring
431Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect.
432Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect.
433C.P. brass Bib cock long nose/ long body without flange
434C.P Brass bib cock foam flow without flange
435Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect.
436C.P.brass 15mm Concealed stop cock with flange
437C.P.brass 15mm Angle valve without flange
438Providing and fixing in position premium range C.P. Brass Fittings and accessories of approved make (to the approval of Engineer-in-charge ) complete in all respect.
439C.P. Brass fittings:
440C.P. brass Bib cock with Wall flange
441C.P.brass 15mm Angular stop cock with Wall flange
442C.P. brass 15mm Concealed stop cock with adjustable wall flange with seal.(Outer +Inner Body)
443C.P brass Sink mixer with swinging spout.(wall mounted)
444C.P. Brass Accessories:
445C.P. brass towel rail 600 mm long
446C.P brass towel ring square
447C.P. brass soap dish holder with glass dish
448C.P. brass toilet roll holder with flap
449Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect. PVC tube connection of size 15 mm x 375 mm with PTMT nut
450Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect.
451Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long
452Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on top complete in all respect (as required by the Engineer-in- Charge) Size 1500mmx600mm or any other size
453Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Tripple Layer Tanks
454Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod and Plastic Ball
45525mm i/d
456Providing and fixing in position Cpvc Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
457Cpvc tank nipple 32mm i/d
458Providing & fixing in position Water Dispenser Top Loading (with refrigration capacity 15 ltr) of approved make (to the approval of Engineer-in-charge ) dispensing hot/cold/ambient water including cost of two no. 20 ltrs packaged drinking water bottles and carriage complete in all respect.
459Supply & Installation of Sanitary pad vending machine NVM-50, fully Automatic Vending machine battery backup available visible window as per specification and as desired by Engineer-in-Charge complete in all respect.
460Supply & Installation of Sanitary Napkin Vending machine storage capacity 25 Pad, Coin accepted : 5rs or dummy coin made from Mild steel as per specification and as desired by Engineer-in-Charge complete in all respect.
461Providing and fixing in position SS Grab Bar Grade 304 of approved make (to the approval of the Engineer-in-charge) fixed in to wall with brass screws complete in all respect.
46235mm dia 600mm (24”) long
46335mm dia 1200mm (48”) long
464Foldable U Type 762mm long
465Sub Head-4 Flooring and Wall Tile
466Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material
467Total All Floor
468Extra rate for Second Floor
469Providing and laying Rectified Porcelin floor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 ( 1 Cement : 4 Fine sand) for new flooring complete .
470Total All Floor
471Extra rate for Second Floor
472Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: i) Ist course of applying cement slurry @ 4.4 Kg/ sqm mixed with water proofing compound conforming to IS : 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm).
473Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600 x 300 mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
474Total All Floor
475Extra Rate for Second Floor
476Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps..
477Total All Floor
478Extra Rate for Second Floor
479Extra for pre finished nosing to treads of steps of marble stone. ( Full gola, half round gola etc.)
480Sub Head -5 Drinking Water Coller & Air Conditioning System
481Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect.
482Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer
483Providing & fixing in position Commercial RO without reservoir with four no cartridge/ membrane having flow rate 50 ltr/hr with 6 stage purification process of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
484Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to the approval of Engineer-in-charge ) including carriage and fixing in position complete in all respect.
485Supplying, Installation, errection, testing and commissioning of split type room air conditioner (with copper condensor coil) having capacity of 1.0 TR with 5 Star ISEER Rating and cooling capacity of 3500 watts or above (Cooling Only) with invertor technology. Air conditioner conforming to IS:1391 (part-2) - 1992 with amendments No. 1 & 2 fitted with Rotary compressor operating on Refrigerant R-32 including 10feet 12.7mm o/d Copper pipe, wall mounting anlge iron base frame/Stand for Out door unit completer in all respect and as desired by Engineer-in-chargeNote :1) Contract will provide warranty of OEM for atleast 5 years for Compressor and PCB.2) Contractor will ensure jointless cable connection between indoor and outdoor unit of the Air Conditioner
486Supplying, Installation, errection, testing and commissioning of split type room air conditioner (with copper condensor coil) having capacity of 1.50 TR with 5 Star ISEER Rating and cooling capacity of 5400 watts or above (Cooling Only) with invertor technology. Air conditioner conforming to IS:1391 (part-2) - 1992 with amendments No. 1 & 2 fitted with Rotary compressor operating on Refrigerant R-32 including 10feet 12.7mm o/d Copper pipe, wall mounting anlge iron base frame/Stand for Out door unit completer in all respect and as desired by Engineer-in-chargeNote :1) Contract will provide warranty of OEM for atleast 5 years for Compressor and PCB.2) Contractor will ensure jointless cable connection between indoor and outdoor unit of the Air Conditioner
487Supplying, Installation, errection, testing and commissioning of split type room air conditioner (with copper condensor coil) having capacity of 2.00 TR with 5 Star ISEER Rating and cooling capacity of 6350 watts or above (Cooling Only) with invertor technology. Air conditioner conforming to IS:1391 (part-2) - 1992 with amendments No. 1 & 2 fitted with Rotary compressor operating on Refrigerant R-32 including 10feet 12.7mm o/d Copper pipe, wall mounting anlge iron base frame/Stand for Out door unit completer in all respect and as desired by Engineer-in-chargeNote :1) Contract will provide warranty of OEM for atleast 5 years for Compressor and PCB.2) Contractor will ensure jointless cable connection between indoor and outdoor unit of the Air Conditioner
488Supply and erection of Single phase copper wound Automatic voltage stablizer of suitable capacity electronically controlled circuit with input voltage 140-260 volts single phase AC supply and output voltage 220 ± 5% volts single phase AC supply having main silicon core copper wound step up transformer with suitable nos. of turns on primary side and secondary side the transformer should be fully insulated inside the MS sheet box of suitable size. There should be power control relay and single pole MCB (C-curve, 10kA) of suitable capacity complete with internal copper wiring along with amp. meter and volt meter, high voltage cut off 280 volt input (240 volt output) and 90 volt maximum boost and overloading protection to be provided:-
489Automatic Voltage Stablizer 2 KVA Drinking Water Cooler & 1.00 tonne AC
490Automatic Voltage Stablizer 4 KVA for Split AC 1.50 tonne
491Automatic Voltage Stablizer 5 KVA for Split Ac 2.00 tonne
492Providing laying hard soft copper concealing of copper pipes of dia 12.7mm od (insulation = 13mm)/9.5mm od (insulation = 13m) as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects.
493Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.uPVC Pipe 10 Kgf/cm225mm i/d
494Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I pipes line and making good the same to its original condition. Size 75 mm x 75 mm
495Sub Work-2
496Sub Head-1 Construction of UGSR 50000 ltr with Pump Chamber capacity for portable water & fire fighting arrangement
497Earth work in excavation for storage and sedimentation tanks, high level tanks, filter beds, clear water reservoirs, pump houses, sumps, screening chambers and other similar works having straight or open cuttings in foundations trenches etc. with 3D Excavator/ JCB including manually dressing of bed, trimming of sides and side slopes to full dimension and depth as shown on the drawings or as shall be required by Engineer-in-charge, including dressing of bottom and sides of trenches, stacking the excavated soil clear from the excavation and subsequent filling around plinth/structures including watering dressing and disposal of surplus soils as directed upto 15 metre complete in all respects.
498Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
499Reinforced cement concrete M-30 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth including carriage
500Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering)
501Reinforced cement concrete M-30 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture.
502Beams
503Ground Floor
504Ground Floor
505First Floor
506Extra rate for First Floor
507Extra rate for Smooth Surface of RCC
508Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
509Ground Floor
510First Floor
511Extra rate for First Floor
512Extra rate for using steel produced in integrated plant from original ores complete in all respect as per the directions of Engineer-in-charge.
513Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering) including attached pillasters, buttersses etc when curved.
514Ground Floor
515Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc.
516Ground Floor
517First Floor
518Extra rate for First Floor
519Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels
520Ground Floor
521First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level.
522Ground Floor
523First Floor
524Extra rate for First Floor
52512.5mm thick cement plaster 1:5.
52612.5mm thick cement plaster 1:4.
527Supplying Pressed steel sheet frames (chowkhat) consisting of 18gauge (1.25 mm thick steel sheet of the specified section, including iron lugs (hold fast) iron hinges conforming to PWD specification including bolts for fixing stops lock notch provision for receiving tower bolts and finished with 1 primer coat approved quality, fixed in position excluding the cost of cement concrete 1:3:6 for fillings in the frame and cement concrete 1:2:4 for lugs complete
528Doors and windows frame of size 151mm x 60mm with 35 mm wide double rebate weighing 3.95 kg per meter
529Providing & fixing of Box type steel windows, made of various ERW section outer 60mm x 25mm, central mullion 60mm x 25mm, for shutter 50mm x 20mm having thickness of 1.25mm (18 gauge), shash bar MS Tee 25mm x 3mm where required joints mitred and electrically flash-welded, with iron fittings incluidng necessary iron handles,hinged cleat, tower bolts, iron hold fast and pintle hinges complete (excluding glazing and wire guage) and finished with ready mixed paint red lead non setting primer complete as per specification, Drawings and to the entire satisfaction of engineer-in-charge. (Note:- Glazing, wire guage and grill will be paid as per respective items)
530Extra for providing & fixing Steel Tube beading size 12mm x 12mm, 18 guage of approved shape and section with screw for fixing of glass panes in stead of glazing clips and metal slash putty in steel doors, windows & Ventilators complete in all respect
531Wire gauge fixed on steel windows of standard rolled steel section, with 3mm thick flat iron cover moulding of 12.5mm width, fixed with machine screws, complete in all respects.
532Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position.
533Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make. Glass panes 4mm or 10.75 kg / sqmexceeding 0.4 sqm of area
534Factory manufactured solid flush door fixed in position iron hinges, etc (excluding the cost of any fittings other than specified above but including labour for fixing the same in position (Code : II Revision IS-202 Part-I) 1999,Commercial with elm or gurjan facing on both \ Sides with laminated core and lipped edges:-35mm thick
535Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm
536Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300mm x 16mm
537Applying priming coat with metal primer on new steel or iron work including preparation of surface.
538Preparation of plywood surface for painting including sand papering the surface and applying filling with approved quality fillers consisting of white lead, linseed oil, Varnish, and Chalk Mitti including finishing the surface to required finish complete.
539Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
540Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
541Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm
542Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).R.C.C. Manhole cover 560mm i/d RCC man hole cover with frame as per ISI
543Foot Rest for Manhole.Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
544Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material
545First Floor
546Extra rate for First Floor
547Conglomerate floor 50mm thick cement concrete topping 1:2:4 (Using mechanical mixer for mixing of material).
54820mm thick grey polished skirting or dado consisting of bottom layer of 16mm thick cement sand plaster 1.3 and finished 3mm thick topping of neat cement rubbed and polished including rounding of junction with floors.
549Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing
550Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified.
551Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS ClampU-PVC pipes (working pressure 4kgf. / sqcm)pipe 110 mm dia.
552Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm bend
553Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.
554Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16.
555Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3.
556Providing and fixing in position gratings 150mm x 150mm for gully trap.PVC grating
557Providing & installing,testing & commisioning of 1 no electrically driven Boosting Pump set of 5.00 BHP (KSB / crompton equilent make capable of delivering 410 LPM against a head of 30 mtr complete in all respect as per specifications
558Providing & fixing 2.50mm2 core cable to Submersible Pump complete in all respect as per specifications
559Providing & installation of smart starter panel board including Automatic Controler of 5BHP complete in all respect.
560Sub Work-3
561Sub Head-3.1
562Sub Head-1 Estate Sewerage system
563Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects.
564160 mm o/d pipes
565Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
566Depth not exceeding 3 m. BGLAll kinds of soil except rocky
567Providing and filling sand grading as per specifications or fine grade around the various sizes of G.I. pipes in external work.
568Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard
569Inside size 90x150 cm
570Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works, upto one chain (15m) complete in all respects.
571For depth not exceeding 3.0 m B.G.L.For all classes of soil except rocky
572Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type
573First class burnt brick work laid in cement sand mortar 1:4 in foundation and plinth
574Cement Concrete 1:2:4 with stone ballast or shingle.using concrete mixing volumetric type
575Floating coat of 1:5mm thick neat cement laid in one operation to the topping
57612.5 mm thick cement plaster 1:3
577Cement rendering on plaster 1mm thick
578Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.
579Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete
580Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer's permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design
581Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD).RCC Man hole cover with Frame560mm i/d RCC man hole cover with frame as per ISI
582Sub Work-4
583Fire Fighting Arrangements as per NBC Norms
584Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect.4.5kg capacity
585Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 6kg Capacity
586SITC of MS PipeProviding, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects.
587100mm internal diameter
588150mm internal diameter
589200mm internal diameter
590SITC of Butterfly valveSupplying, Laying, Testing and Commissioning of ISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked complete with rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications.
591100 mm i/d
592150 mm i/d
593200 mm i/d
594Proving & fixing ISI Marked Non-return valves flanged end class PN-1.0 as per IS:5312/2004 in pipe lines including jointing & cost of Nut Bolt , rubber insertion etc. complete.Note: If Non-return valves class PN-1.6 is used instead of class PN-1.0 , than 5% will be paid extra.Class PN-1.0 as per ISI with rubber Flap
595100mm i/d Non-return valve
596150mm i/d Non-return valve
597200mm i/d Non-return valve
598Providing and fixing fire brigade inlet connection of cast iron body with Gun metal 63mm dia instantaneous type male coupling with built in check valves and 150mm dia flanged outlet complete with bolts, nuts and rubber insertions as per IS:904. (to be connected to static tank).
599Four Way inlet connection
600Supplying, Installation, Testing and Commissioning of G.M Single headed hydrant valve with instantaneous Gun metal peet coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (TypeA) with blank Gunmetal Cap and chain including orifice plate made of 6mm th Stainless steel to keep the pressure not more than 3.5 per sqcm at any point complete in all respects.
601Supplying, Installation, Testing and Commissioning 63 mm dia gun-metal Branch Pipe (ISI marked) with 20mm (nominal internal dia) size Gun metal nozzle confirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required.
602Supplying, Installation, Testing and Commissioning of RRL FIRE hose Type A, IS:636, 63mm dia x 15m long with gunmetal male & female couplings (ISI marked) bound & riveted to hose pipes with copper rivets and copper wire as required.
603Supplying, Installation, Testing and Commissioning of Non-percolating flexible CP HOSE as per IS:8423 / 1994 ISI marked 63mm dia x 15 m long complete with instantaneous type gun-metal 63 mm dia male & female coupling (IS: 903) bound and riveted to hose pipes.
604Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type-2, hose reel Drum with bracket as per IS:884, 20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect.
605Supplying, Installation, Testing and Commissioning standard Fire Man's axe with heavy insulated rubber conforming to IS 936 complete in all respect.
606Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc.
607600 mm wide x 600 mm high x 300 mm deep Size - (for RRL Reel)
608Supplying & fixing air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mm height with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required
609Providing and fixing of Pressure switch of approved make in MS pipe line suitable for line presure up 15kg/cm2 & including connection with main panel etc. as required complete in all respect
610Providing and fixing S.S Pressure Gauge complete as required complete in all respect.
611Dial diameter 150mm calibration 0-16 Kg
612Dial diameter 100mm calibration 0-16 Kg
613Supplying, Installation, Testing and Commissioning of cast iron flanged Y type strainer with stainless steel mesh in PN-1.0 including cost of Nut Bolt , rubber insertion complete in all respects.
614200 mm i/d
615Providing & fixing Fire Hydrants with jointing including all carriages complete. (without Fire Hydrant surface box) Size 80mm complete in all respect.
616C.I Fire Hydrants 1S-908
617C.I Fire Hydrants S.V. Type IS-909
618Supplying and Installation control valve C/W water motor gong complete with alarm Valve, constant trim, water motor bell, 2No. Pressure Gauge. All parts UL listed. complete in all respect.
619100 mm control valve
620Providing, laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. in ground with anti corrosive treatment with wrapping coating tape (4mm pypkote tape) as per IS : 10221 including cost of primer etc. excluding cost of excavation and refilling complete in all resepcts.
621100mm internal diameter
622150mm internal diameter
623Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect.
624XLPE INSULATED ARMOURED CABLES (UNDERGROUND):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed armoured and served cable 1100 volts grade as per IS:7098 (Part-1)1988 to be laid 1metre below ground level including excavation, sand cushioning, covering with sand & First Class bricks and back filling the trench etc., of the required size as per PWD General Specifications:-
625Overall size 16sq.mm (3Core) Armoured (Underground)
626Providing and fixing in position automatic brass Ball Cock in tanks.Plastic Ball Cock with rod and Plastic Ball
62732mm i/d
628Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect.
629G.I. tank nipple 32mm i/d
630Terrace Pump, 450 lpm at 35m headSupplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. d) Suitable cement concrete foundation duly plastered and with anti vibration pads.(Note :- The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/fathest point)
631Jockey Pump, 180 lpm at 56m headSupplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.(Note :- The head of the pump is selected in a manner so as to give a minimum 3.5kgf/cm2 pressure at the highest/fathest point)
632Diesel Pump, 2280 lpm at 56m headSupplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mmthick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads.
633Electric Pump, 2280 lpm at 56 m HeadSupplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325. M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered with anti vibration pads.
634Electrical CONTROL PANELS5 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors,dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD specification with following in coming and Outgoings, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :INCOMING 250A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Digital Ammeter (0-250 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 300A OUTGOING ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 60 HP pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump 63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. DIESEL ENGINE CONTROL PANEL
635DIESEL ENGINE CONTROL PANELControl for diesel engine comprising - Automatic/Manual selctor switch & 3 attempts starting device, timers and relays as required, push buttons,start/stop in manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC Ammeter All standard relays and accessories for automatic operation of diesel engine System Controller Designing, Supply, Installation, Testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in sequence as per specification consisting of relays, timers. Sensors, annunciation window for fault indication, complete as per specification Incomings 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with selector switch Ammeter (0-400 A) with selector swtich & CTs etc. LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A Outgoings ( Note : All outgoing feeders for pumps should have digital Ammeter with selector switches, and LED type ON, OFF, trip indicating lamps) Main Fire Pump 200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. Jockey Pump 100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation.
636Sub Work-6
637Provision for Shifting of Terrace tank pipe line from Terrace of First Floor to Terrace of Second Floor
638Removing & placing in position on terrace (at all floor levels) existing HDPE water storage tanks fixing over flo pipes but without fittings and base support for tank. complete in all respect and as desired by Engineer-in-charge
639Construction of Plateform complete as per specification & as desired by Enginer-in-charge
640For 5000 ltr Water Tank
641For 2000 ltr Water Tank
642For 500 ltr Water Tank
643Taking out dismantled Cast Iron flanged or socketed / G.I/D.I Pipes valves and, specials etc. out side from the trenches and Stacking the same as desire by Engineer-in-charge complete in all respects.Upto 100 mm internal diametre of pipe.
644laying, fixing, testing and commissioning of 'C' Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. (Labour Rate)100mm internal diameter
645Dismantling, disjointing, removal of G.I. pipe lines, specials, valves and fittings complete in all respects.
64625mm internal diametre pipe line.
647Laying, jointing, fixing and testing ISI Marked G.I. Pipe (as per IS 1239) B-Class including cost of specials (such as tees, bends, sockets, elbows etc.) ,painting with anti corrosive bitumastic paint, testing, cutting, threading Inside building complete. (Labour Rate)
64825mm i/d
649Shifting of Existing AC Outdoor unit from Rooftop First Floor to Rooftop Second Floor Supplying, Installation, errection, testing and commissioning of split Outdoor AC Unit 2.0 TR /1.5 TR /1 TR withour copper pipe and filling of Refrigerant R-32 suitable for wall mounting angle iron base frame/stand for outer unit in all respect and as desired by Engineer-in-charge
650Providing laying hard soft copper concealing of copper pipes of dia 12.7mm od (insulation = 13mm)/9.5mm od (insulation = 13m) as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects.
651Shifting of Existing AC from Rooftop First Floor to Rooftop Second Floor
652ELECTRICAL SERVICES
653Providing Internal Electrical Installations:
654POINT WIRING:
655RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
656Wiring fan point with sheet metal fan box
657Wiring light point
658Wiring call-bell point
659Wiring 3 pin 6 Amp. wall socket point
660Wiring 3 Pin 6 Amp. Plug control comprising wall socket point
661Wiring 3 pin 16/20 amp. power plug control point
662Wiring light point without control switch.
663Wiring light point with double control switches.
664RECESSED COMPUTER SUPPLY TERMINAL POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring Computer supply terminal points recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10/16/20Amp. Switches and blanking plate etc., and covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
665Wiring Computer terminal point having 3 Nos. 6Amp. 2/3 universal socket (shuttered), 1No. 16 Amp. switch with indicator and 1No. blanking plate (Modular accessories).
666RECESSED AIR CONDITIONER SUPPLY TERMINAL POINT (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Wiring air conditioner supply terminal point recessed in wall etc., complete with powder coated/anodized concealed metal boxes required for suitable number of modules (Modular accessories) for having 25Amp. combined/ universal Socket (shuttered) and modular motor starter 25Amp. (2Module), covered with Frame Plate and other petty material etc. including the cost of above material, cutting and filling up of chases (with finishing the surface):-
667Wiring AC supply terminal point having 1No. 25Amp. universal Socket (shuttered) erected at AC height and 1No. Motor starter 25Amp. erected at switchboard height.
668SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of switches, sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including fixing & connections and petty material etc.:-
669Ceiling Rose (Flush Piano type)
670Call Bell 220/230 volts AC Ding Dong
671LED'S FIXTURES & FANS:
672Supply and erection of Slim Recessed mounted, Round downlighter 18 watt with Pressure die cast aluminium housing & polycarbonate diffuser with surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt and operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 3 %, housing & driver shall be of same brand, supported with LM 79 reports not more than 2 years old from NABL /UL accredited laboratory complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. The certification and specifications of the LED Fitting's should be as approved by O/o Advisor (Technical), Govt of Punjab vide Letter no.AT/2021/GL/1410-1422 Dated 06/05/2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
673Supply and erection of LED batten 20 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
674Supply and erection of LED batten 40 Watt LED (including constant LED driver) with High quality extruded aluminium with efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
675Supply and erection of Recessed mounted 36watt LED panel (including LED driver) with CRCA sheet having efficacy of LED fixture minimunm 100 lumens per watt and operating voltage between 140 to 270 volt, THD <10% ingress protection IP20 (as per latest BIS standards) surge protection - 2.5 KV and above (as per IS/IEC standards) wattage of each low power LED less than 1 watt input AC frequency 50 Hz ± 3 % with 5 year warranty including there drivers complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter ION No: AT/2021/GL/1410-1422, Dated: 06.05.2021. Besides this the lighting fixtures manufactures should have in house NABL accredited laboratory.
676Supply and erection of BEE 3-Star rating AC Ceiling Fan 1200mm (48\\") suitable for 230 V single phase with double ball bearing, copper wound, full aluminium body, 3Nos. of blades, white in colour. The mounting type is down rod mount. The product should possess a minimum air deleivery of 210 CMM (approx.). The rated speed of the the product must be minimum of 300 revolutions per minute and 5Nos. of speeds. The product should have a manufcaturer's guarantee /warranty of minimum 2 years. The product should be complete in all aspects with fan motor, bladeset, down rod, conopy set, shackle kit, twisted wire etc., including erection & testing of ceiling fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75 sq. mm complete in all respects as per satisfcation of the Engineer in-charge at site.
677Supply and erection of Wall Fan Plastic Body 400MM, 16\\" including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
678Supply and erection of Heavy duty Exhaust Fan 300mm, 900RPM with aluminium louver shutter, double ball bearing longer life including flexible wire & petty material etc. for connections and testing complete in all respect as approved and desired by the Engineer in-charges at site.
679OCCUPANCY SENSORS:
680Supply and erection of Ceiling mounted Occupancy based PIR sensor (360° detection angle motion detector) with installation height 3mts, 8.5 Amps resistive load, Detection dia 8M, time delay - 5s to 59 mins , Light level threshold - 5 to 1275 Lux, IP - 20, Sensitivity Adjustment, Walk LED test, with additional options like walkthrough, daylight set point, vacancy complete in all respect as approved and desired by the Engineer in-charges at site.
681SUSPENSION RODS FOR CEILING FANS:
682HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
683Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), white painted suspension rod for ceiling fan.
684CONDUIT PIPE & COPPER WIRES:
685PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
686Heavy gauge PVC conduit pipe 20mm dia. (ISI marked) Flushed
687Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
688Heavy gauge PVC conduit pipe 32mm dia. (ISI marked) Flushed
689Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed
690PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
691Overall size 1sq.mm (Un-sheathed)
692Overall size 1.5sq.mm (Un-sheathed)
693Overall size 2.5sq.mm (Un-sheathed)
694Overall size 4sq.mm (Un-sheathed)
695Overall size 6sq.mm (Un-sheathed)
696Overall size 10sq.mm (Un-sheathed)
697Overall size 16sq.mm (Un-sheathed)
698Overall size 25sq.mm (Un-sheathed)
699MAIN VERTICAL DISTRIBUTION SYSTEM:
700Supply and erection of sheet metal double door vertical distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2 Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting MCCB's as incomer and outgoings SP/TP miniature circuit breakers in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.:-
701TP&N Double Door Vertical DB's 8 way each (With provision of FP MCCB upto 125amp.)
702MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-
703MCCB Four Pole 125amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
704SUB DISTRIBUTION SYSTEM:
705SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
706TP&N Vertical Double Door Distribution Board 4 way each.
707TP&N Vertical Double Door Distribution Board 8 way each.
708Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-
709Cable End Box for TPN Vertical 4/8/12Way
710MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
711MCB Single Pole 6-32amp. (10kA, Curve-C)
712MCB Four Pole 40amp. (10kA, Curve-C)
713MCB Four Pole 50, 63amp. (10kA, Curve-C)
714MS SHEET ENCLOSURE FOR MCCB's:Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- (FOR SOLAR POWER PLANT)
715MS Sheet Enclosure having provision for MCCB 200-630Amp.with extended rotary handle (Approx. Size 750mm x 300mm x 250mm)
716MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- (FOR SOLAR POWER PLANT)
717MCCB Four Pole 250amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
718Supply and erection of PVC flexible pipe complete without compression glands, locking arrangement, check-nuts as required:-
719PVC flexible pipe 40mm dia.
720Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:-
721PVC compression Socket gland 40mm dia.
722EARTHING SYSTEM (INDOOR):
723COPPER EARTHING 8SWG :- Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
724Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
725Fixing additional Length of earthing with 8 S.W.G. (4mm dia.) copper wire in G.I. pipe with sockets, elbows, steel hooks and GI saddle clamps including painting etc.:-
726Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (Flushed)
727COPPER EARTHING :-(Upto 14 metre in Length):-Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
728Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length)
729COPPER EARTHING STRIP (As Additional Length):Fixing additional Length of earthing with Copper Tape (On Surface/Flushed) with petty material as required etc.:-
730Additional Length 20mm x 3mm thick Copper Tape .
731INDOOR LT CABLES, CABLE TRAY, DWC PIPE , BRASS GLANDS & THIMBLES:
732XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
733Overall size 6sq.mm (2Core) Un-armoured (Loose)
734Overall size 16sq.mm (4 Core) Un-armoured (Loose)
735Overall size 70sq.mm (3½ Core) Un-armoured (Loose)
736Overall size 95sq.mm (3½ Core) Un-armoured (Loose)
737Overall size 150sq.mm (3½ Core) Un-armoured (Loose)
738CABLE TRAY:Supply and erection of MS perforated cable tray (MS Sheet thickness 2mm) with DA gray paint on the existing surface with the help of MS angle iron support (to be painted with approved paint) of size 50mm x 50mm x 6mm thick to be fixed with fastners/ nut & bolts etc., complete in all respect as desired by the Engineer-in-charge and as per PWD General Specifications:-
739Cable Tray Size 300mm x 50mm x 50mm (2mm thick)
740DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1/2mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
741Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.)
742Double Walled Corrugated HDPE Pipe 90/76mm (Outer/ Inner dia.)
743Double walled corrugated (DWC) HDPE pipe120/103.50mm (outer/ inner dia.)
744Double Walled Corrugated HDPE Pipe 160/ 136mm (Outer/ Inner dia.)
745Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:-
746Brass Gland for Aluminium cable 2/3/4 Core size 6sq.mm
747Brass Gland for Aluminium cable 2/3/4 Core size 16sq.mm
748Brass Gland for Aluminium cable 3/3½/4 Core size 70sq.mm
749Brass Gland for Aluminium cable 3/3½/4 Core size 95-120sq.mm
750Brass Gland for Aluminium cable 3/3½/4 Core size 150sq.mm
751Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
752Aluminium thimble cable Core size 4 - 6sq.mm
753Aluminium thimble cable Core size 10 -16sq.mm
754Aluminium thimble cable Core size 50sq.mm
755Aluminium thimble cable Core size 70sq.mm
756Aluminium thimble cable Core size 95sq.mm
757Aluminium thimble cable Core size 150sq.mm
758Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:-
759Copper thimble cable Core size 4 - 6sq.mm
760Copper thimble cable Core size 10 - 16sq.mm
761SAFETY EQUIPMENTS:
762Providing and fixing of 4.5 Kg. Capacity FIRE EXTINGUISHER,CO2 type as per IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect
763Providing and fixing of 6 Kg. Capacity FIRE EXTINGUISHER, ABC Powder type (stored pressure) asper IS:15683 complete with all accessories as per Manufactures Specification. ISI Mark complete in all respect
764Providing Advance Lightning Protection System:
765Supply, erection, testing & commisioning of Early Streamer Emission (ESE) type Lightning Protection Complete with Lightning Air Terminal. The System should be corrosion resistant stainless steel chrome body capable of working in hazardous atmosphere and protecting against direct Lightning point as well conducting /diverting it to earth completely after tracing the Lightning in advance. As per NF C 17-102:2011 the air terminal should be tested for Lightning impulse current (10/350 micro sec) =100 KA and for local certification the air terminal should be tested for switching impulse current of 40 KA (8/20 micro sec) as per CPRI with 5 positive and 5 negative impulse. The ESE Terminals shall offer a protection radius of 79mtr., Level-1 High Protection and preferably to be mounted on roof top and center of the building / blocks with the highly insulated polyplastic adaptor with the Mast. (Its working principle evolves from local electrostatic field that develops naturally around the system as a thunderstorm begins to gather. In the event of descending lightning, an inbuilt triggering device generates high tension pulses at the conductor tip, causing a ‘corona effect’.) Protection radius of 79Mtr at level 1 & 107 Mtr at level 4
766Supply and fixing of GI Mast 5 mtr. height along with suitable base plate for mounting the terminal along with highly insulated adopter to mount ESE Air Terminal with the Mast.The Adapter shall have suitable Metal connector /Connecting point in such a way the top portion shall be electrically connected to the central tip of the ESE terminal and bottom portion connected to the down conducto, stray wires along with support shall be securely fixed with base plate and gauge wires where ever required.
767Supply and installation of Lightning Strike Counter (6 digit display) of non-resettable (electromechanical) type which allows the automatic counting of the strikes received by the lightning protection system. This information is used to enhance lightning protection security & increase the effectiveness of inspection & maintenance procedures. It should be in IP-65 enclosure with minimum sensitivity of 1KA and maximum capacity 100KA. No external power source is required. It should be installed always 2 mtrs. above the ground level.
768Supply & erection of test Link of non-corroding, weather proof, water proof polycarbonate IP 65/55 enclosure including providing of 2 Nos. of insulated supports with suitable holes prefitted nuts & bolts to fix the down conductor & earth wire. The transparent cover fitted at approximately 500-1000mm from ground level shall be provided on each down conductor complete in all respect as approved and desired by the Engineer in-charges at site.
769Supply, installation & testing of chemical earthing (Maintenance Free Earthing) system with UL approved copper bonded rod and exothermically welded copper busbar both tested by CPRI at 50kA Fault Current. A copper bonded steel rod shall have 3000 mm length and 17.2 mm dia. with copper coating thickness of minimum 250 microns. Along with earth enhancement compound tested by ROHS complying IEC 62561-7 in a sealed bag of minimum 50 kg (25 kg Bag x 2). A copper clad steel solid ground wire of 8 mm dia. for interconnecting earth pits. Each earth pit shall be covered with heavy duty weather proof environment friendly polyplastic earth pit chamber. The grounding minerals should not be pollute the ground water. The grounding minerals shall be tested & certified for the resistivity of less than 0.12 ohm-mtr.
770Cost of pole foundation with earth work in excavation in foundations trenches etc. 0.25 meter below ground level, Cement Concrete 1:4:8 with stone ballast, Reinforced cement concrete M-20,Cold twisted deformed (Ribbed/tor Steel Bar) Bars Fe 500 grade as per IS 1786-2008 complete in all respect as desired by engineer in charge.
771PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
772Overall size 70sq.mm (Un-sheathed) (Conductor connected the air terminal to earthing)
773Providing 3 Nos. 13 Passenger Lifts, 3Stops:
774Supply, installation, testing and commissioning of 1 No. lift of 13 passengers machine room less.Type and Capacity : Approximately 884 Kg, 13 Passengers Speed:1.0 Meter per second Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor. Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way Travel: Approximately 8 meter________ Serving: _3 Floors _3Stops _ 3Openings _3Levels (All on the same side) Hoist way Required: 2050mm (Wide) x 2500mm (Deep) Clear dimensions Headroom Height (HR): 5000 mm beyond finished floor level of last landing Pit Depth: 1600mm below the finish floor level of first landing Car Size Area: Minimum 2.06 square meter and Maximum 2.20 square meter Car Enclosure: Constructed out of stainless steel Scratch proof Finish (Vandal Proof) with Honeycomb finish/hairline finish.Car Entrance: Center Opening Automatic Doors with ACVF drive (all landing doors must be fire-rated for a minimum of 120 minutes, classified as EI120 according to EN 81-58) of Stainless steel finish panel in Honeycomb finish/Hairline/ Vandal proof with a clear opening of 900mm/1000mm (wide) x 2000mm/2100mm (high) Door operation: Automatic DC Door operation with adjustable door opening and closing timings Control: Simplex full selective collective control with and without attentdent Operation: Automatic Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current Flooring: Floor Skid - Resistant as per standard Fan: Blower Fan in Car for ventilation with Auto cut off Lighting: LED for Car Lighting Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear) Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level Std. Govt. features.
775Other Features: 1. Battery operated emergency light with rechargeable battery 2. Battery operated emergency alarm with rechargeable battery 3. Adjustable Guide shoes 4. Micro movement LED based buttons 5. Door Open and Close buttons 6. Emergency Intercom provided inside the elevator 7. Emergency Intercom usable without the voice communication 8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication 9. Steel items, door frames sill angle's, fascia plates, spring buffers10. Automatic phase reversal device and Phase Failure protection11. Call registration 12. Audio & Video System installted in the lift indicating arrival at a floor 13. Manual break lever 14. Additional car gate lock 15. Automatic break testing infrared safety curten 16. Braille Buttons (Inside and outside) with Braille instructions for the communication system 17. Kick plate/Skirting 18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close 19. Car Operating Panel 20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive 22. Fire Man switch at main lobby 23. Car false ceiling in stainless steel 24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging 27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure.28. The use of visually and accoustically reflective wall surace should be minimized within the lift car as visual reflections can cause discomfort and affect the visual acuity of people with impairements.29. The floor of lift car should be slip resistant and have similar frictional qualities to thye floor of lift landing to decrease the risk of stumbling.30. The provision of mirror on the wall of the lift car opposite the lift door not extend below 900mm from the lift floor to avoid confusing people with impaired sight.31. The emergency communication system should be coupled with an induction loop system installed all around the lift. Telephone units, where provided, should have an inbuilt inductive coupler to assist persons using hearing aids.
776XLPE INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-
777Overall size 16sq.mm (4Core) Un-armoured (Loose)
778XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-
779Overall size 16sq.mm (4Core) Un-armoured (On-Surface)
780DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
781Double walled corrugated (DWC) HDPE pipe 63/51 mm (outer/ inner dia.)
782COPPER EARTHING (8 SWG COPPER EARTHING): Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-
783Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long
784Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface)
785MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (conforms to IEC:60947-II) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD General Specifications (Electrical Works) complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of Thimbles etc.
786MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
787MS SHEET ENCLOSURE FOR MCCB's:Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:-
788MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
789SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-
790SP&N Double Door Distribution Board 8 way each
791Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:-
792Cable End Box for SPN 8 Way
793MINIATURE CIRCUIT BREAKERS:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:-
794MCB Single Pole 6-32amp. (10kA, Curve-C)
795MCB Double Pole 6-32amp. (10kA, Curve-C)
796Providing EPABX System:
797Supply, installtion, testing & commisioning of Analog phone with caller id and hand free facility complete in all respect as per satisfaction of the Engineer in charge of the work.
798Supply Installation Testing and Commissioning of 20 Pair DB with Original Krone Module lock & key facility complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.
799RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module), covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
800Wiring Telephone socket point RJ11 (one module)
801Supply and erection of telephone cable with solid bare copper conductor, special grade PE insulation, paired, polyster taped, nylon rip cord, FR PVC sheathed, conforming to TEC Specification No. G/WIR-06/03 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
802Telephone Cable 0.5 Sq.mm, 2 Pair
803Telephone Cable 0.5 Sq.mm, 20 Pair
804PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
805Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
806PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
807HDPE Electrical Conduit Pipe 25mm dia. (Flushed)
808HDPE Electrical Conduit Pipe 40mm dia. (Flushed)
809Providing Networking System along with allied accessories:
810Supply, Installation and Comissioning of Distribution Switch with minimum usable 24 10/100/1000BASE-T ports, 2 10GBASE-T ports , 4 10G SFP+ ports L3 Stackable Managed Switch with Redundant Power Supply Support.1 x RJ45 console port, RJ-45 port for out-of band-management port for accessing the CLI of the switch and USB port. 168 Gbps Switching capacity or higher or non-blocking architecture. 64 Bytes packet forwarding rate should be 125 Mpps or higher. Switch MAC table should be at least 16K or higher. Physical Stacking up to 9 units per stack. Stacking bandwidth up to 80G and up to 32 devices per virtual stack. Should have 802.1D STP, 802.1w RSTP and 802.1s MSTP Spanning Tree Protocol and ERPS as per standard ITU-T G.8032. BPDU Filter, BPDU restriction, Root restrction. Loopback detection (LBD). IGMP Snooping v1/V2/V3 & IGMP groups 1K or more IGMP groups and require support for IGMP Snooping Fast Leave. MLD Snooping v1/v2 & MLD group 1K or more and require support for MLD Snooping Querier. 16 L3 IP interfaces and IPv4/IPv6 Loopback interface. IPv6 Neighbor Discovery (ND). VRRPv3, Equal-Cost Multi-Path (ECMP) and UDP helper. Static route for both IPv4 and IPv6, OSPFv1, v2 & v3, RIP V1/V2/ng. Should have Policy-based Route (PBR). IEEE 802.1Q VLAN with different type of VLAN like Port based, Voice VLAN, Private, Double (Q-In-Q), Multicast VLAN (ISM VLAN for IPv4/IPv6), 802.1v Protocol VLAN ,VLAN Trunking. should have per-port broadcast, multicast, and unicast storm control to prevents faulty end stations from degrading overall systems performance. port security to secures the access port based on MAC address. Require prevention of DoS attacks, which include Land, Blat, TCP Null Scan, TCP Xmas Scan, TCP SYNFIN, Ping of Death Attack and TCP Tiny Fragment attack. DHCP snooping and DHCP server screening, DHCP server. 802.1X port based and 802.1X host based access control, Identity-driven Policy (VLAN, ACL or QoS) Assignment. RADIUS and TACACS+ authentication. Authentication database failover. QoS (quality of service) IEEE 802.1P for traffic prioritization. 8 queues per port. Different type of QoS priority like Strict Priority Queue and Weighted Round Robin, Strict + WRR, Congestion control using Weighted Random Early Detection (WRED) or WTD. Remark 802.1p priority, Remark ToS/DSCP and Rate limiting in Policy map. Support at least 2K ingress & 512 egress access control entries. ACL based on MAC, IPv4 and IPv6, TCP/UDP port number, User-defined packet contentm, CPU Interface Filtering. Able to manage trough Web-GUI, Fully functional CLI interface and Telnet. Should have multiple Image and configuration support to reduced down time for the switches. sFlow for monitoring traffic in data networks, SNMP v1, v2c, v3 and SNMP Traps and RMON. Support for DHCP Client support for IPv4/IPv6, DHCP server, DHCP Relay and DNS client. Should have SNTP/NTP protocol for time synchronization. CDP/UDLD, Link Layer Discovery Protocol (LLDP) and LLDP-MED.. CDP/UDLD, Link Layer Discovery Protocol (LLDP) and LLDP-MED. Operating temperature should be 0 to 50 ˚C. Switch should be EMI Certificates FCC, CE and Safety Certifications cUL/UL, CB. All Switches, Wireless and its Networkiing Components from Same OEM. OEM Should be International certification for the ISO 45001 Health and Safety Management System, Information Security Management System: ISO 27001, ISO 9001 Quality Management System, ISO 14001 Environmental Management System, and ISO 14064-1 Greenhouse Gas Inventory Standards. OEM should have Indian based operation at least for a period of 20+ years and should have an Annual Turnover of Rs. 500 Crores and above in any of last three consecutive Audited Financial years. (To ensure only principal networking companies participate having strong Product, Support and Service.) complete in all respect as per satisfaction of the Engineer in charge of the work.
811Supply, Installation and Comissioning of Patch Panel should be made of cold rolled steel.Should conform to TIA / EIA 568-C.2 Component Compliant.Should terminate 24 UTP CAT 6 (4 pair) Cables.Should confirm to EIA/TIA 568A wiring Pattern.Each port Should be features the spring-loaded shutter.Should be prevents incomplete mating Should be protects from dust and contaminants.Should be Front and rear port labelling as well as panel identification label.Should be Integral cable management shelf ensures bend radius compliance.Operating Life should be minimum 750 insertion cycles.Should be RoHS compliant.complete in all respect as per satisfaction of the Engineer in charge of the work.
812Supply, Installation and Comissioning of Patch Cord 1 Mtr Patch cord Should be 4 Pairs 24 AWG copper cables.The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper.Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid)UL listed (UL certificate to be provided along with the Bid)Should Have cross separator.Standard length should be available 0.5M to 10M.Should be RoHS compliant. complete in all respect as per satisfaction of the Engineer in charge of the work.
813Supply, Installation and Comissioning of 2 Mtr. Patch cord Should be 4 Pairs 24 AWG copper cables.The Outer Jacket should be Low Smoke Zero Halogen.24 AWG stranded bare copper.Operating temperature range should be -20°C to 60°C.Should minimum comply with proposed ANSI/TIA/EIA-568-C.2.Should be verified by ETL (ETL certificate to be enclosed with the Bid)UL listed (UL certificate to be provided along with the Bid)Should Have cross separator.Standard length should be available 0.5M to 10M.Should be RoHS compliant complete in all respect as per satisfaction of the Engineer in charge of the work.
814Supply, Installation and Comissioning of 27U Network Enclosure Frame-600X800-STEEL with accessories like fan, pdu, cable manager etc. Supply of 27U Enclosure Frame-800X1000-STEEL, Caster Wheels Set of 4 (2 with Brakes & 2 without Brakes),Adjustable Levellers set of 4, Glass Door-800-27U, Metal Door-800-27U-Vented, Side Panels-1000-27U-Vented, Mounting Hardware-(Pack of 20), FHU with 4 FAN 360CFM, Vertical Power Distribution Unit with 12 x 5/15 sockets Round Pin, 230 Volts AC, 32 Amp with Plug, Vertical Cable Manager-27U-Loop, Horz. Cable Manager-1U-Loop, Conforms to DIN 41494 OR equivalent ISO Standards, Adjustable 19” equipment mounting verticals provide the better mounting flexibility maximizing the usable mounting space, Depth adjustable mounting slots, Top and bottom Panel with ventilation and cable entry facility, Provision to mount the cooling fans on the top panel, Powder coated finish with pretreatment process meeting all industry standards, Grounding and Bonding Options can be provided, 100% assured compatibility with all equipment conforming to DIN 41494. General industrial standard for equipment, Conforms to DIN 41494 or equivalent standard, Welded Frame, Lockable Toughened Glass Door, Metal Vented Door Steel, DIN Standard 10mm Sq. Slots / Direct M6 Tap, 19” Mounting angles made of formed steel Powder Coated, Welded to Frame, Vented and Field Cable entry exit cut outscomplete in all respect as per satisfaction of the Engineer in charge of the work.
815Supply, Installation, Testing and Commissioning of Wall Mount 15U x 600 W x 600 D ,Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of 19\\" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC.as per DIN 41494 Standards complete in all respect as per satisfaction of the Engineer in charge of the work.
816Supply, Installation, Testing & Commissioning of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respects as approved and desired by the Engineer in-charge at site.
817RECESSED TV, TELEPHONE & NETWORKING SOCKETS OUTLET POINTS (USED FOR HGW, PVC CONDUIT & HDPE PIPE WIRING SYSTEM WITH MODULAR ACCESSORIES):Supply and erection of TV socket, Telephone socket and Networking socket points in powder coated/anodized concealed metal boxes recessed in wall required for suitable number of modules (Modular accessories) for having TV sockets, Telephone sockets RJ11 & Networking socket RJ45 (one module),covered with Frame Plate and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface):-
818Wiring Networking socket point RJ45 (one module)
819COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES:Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
820CAT 6 LAN cable
821PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
822Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
823Providing CCTV System:
824Supply, erection, testing & commissioning of IP Bullet/Dome Vari Focal CAMERA 5MP IP Camera STQC Approved with Audio Input Support and following features Resolution - 5 MP (2592 x 1944), Sensor Type and Size-1/2.8\\" SONY - CMOS 5MP Active Pixel Progressive Scan, Back Illuminated Image sensor, Minimum Illumination Color - 0.01 Lux @F1.2 (AGC ON), Monochrome - 0 Lux, Focal Length 2.8mm – 12mm Focus Range - 0.3m to infinity, Field of View (FOV) HFOV – 106 - 32°,VFOV- 73-23,DFOV 142-39, Focus-Automatic focus Aperture (F#) F 1.6 - F 2.8,Iris Type Motorized varifocal, IR Range Up to 50m, IR Led Wavelength 850nm, IR Switching Auto/ Manual , Audio IN 1,Audio OUT 1,Two-way Audio Supported, Audio Compression G.726 and G.711μ Alarm In Yes, Alarm Out Yes, SD Card Up to 512GB, Camera Adjustment Angle Pan: 0° to 360° Tilt: 0° to 90° Rotate: 0° to 360°,No of Stream Profiles 4, Stream Profiles- Profile 1: Mainstream - 2592*1944@ 30fps (H.265/H.264), Profile 2: Sub stream - D1@30fps (H.265/ H.264), Profile 3: MJPEG - 2048*1536@8fps (MJPEG) or D1/VGA@15fps(H.264/H.265) Profile 4:1920*1080@30fps (H.265/H.264/MJPEG) Available Resolutions 2592 x 1944, 2592 x 1520, 2048 x 1536, 1920 x 1080, 720p, D1, VGA, 2CIF, CIF, Max Resolution 2592 x 1944, Bitrate 128 kbps-16Mbps, Bitrate Type CBR, VBR, Video Compression H.265, H.264, MJPEG, Frame Rate 1-30fps, Shutter Speed 1/15s -1/100000s,Adaptive Streaming Yes, ONVIF Profiles S, G, and T, Edge Recording Yes, Alarm Recording Pre and Post, Motion Recording Yes, Time Triggered Yes, Video Parameters Snapshot, Region of Interest (ROI), BLC, HLC, Day/Night Settings, Privacy Masks 8, WDR True WDR (120dB), SNR >70dB Image Enhancement Saturation/ Contrast/ Sharpness/Brightness/Auto Exposure/HVS- Forensics/ Smart IR DNR 2D &3D Video Analytics, Motion/No Motion Detection, Tamper Detection, Trip/No Trip Detection, Object Intrusion/Zone Intrusion, Audio Exception, IP Conflict Yes, Network Disconnect Yes, Storage Full Yes, Upload Image SD, NAS, SFTP, Upload Clip SD, NAS, SFTP Notifications E-mail, SMS, TCP, Supported protocols, TCP/IP, UDP, HTTP, HTTPS, DHCP, DNS, Dyn DNS, DDNS, RTP, RTCP, RTSP, PPPOE, SMTP, NTP, SNMP, FTP, TLS/SSL, SFTP, ICMP, IGMPv2 & v3, ARP, 802.1x, IPv4, IPv6, QoS Layer 3, DSCP, CIFS, SSH, UPnP, Bonjour, Web Viewer Supported in IE 8.0-11.0, Firefox 15.0-47.0, Chrome 20.0-54.0, Browser IE, Chrome, Mozilla, CYBER SECURITY as per ISO/IEC 27402-Secure boot Yes, Signed firmware Yes, Data Encryption All data, including sensitive data, is encrypted with AES 256 and RSA 2048, IP Address Filtering Yes, HTTPs Streaming Yes, using TLS 1.2, Edge Data Encryption Yes, Network Authentication Yes,802.1x Network authentication, Secure Firmware Upgrade Yes, Anti-roll back firmware Yes, Web login Password protection Yes, Unused debug interface protection Yes, Power Supply 12V (DC); 802.3af (PoE), Power Consumption Approximately 7W, Operating Humidity Less than 95% RH (non- condensing), Operating Temperature -30°C to 60°C,Storage NAS, SD Card, BIS, CE, IP67, FCC Part-15 Subpart – B, ONVIF S, G & T, IK10, UL, NEMA 4X* complete in all respect as per satisfaction of the Engineer in charge of the work.
825Supply, erection, testing & commissioning of 32 Channel Linux based Recording server (Network Video Recorder shall be support the STQC Cameras), 4 SATA interface, Up to 32 channel Video Inputs, Servershall have throughput of incoming bandwidth 512Mbps & outgoing 512Mbps, 2* HDMI , 1 *VGA Video output. Supports live view, storage, and playback at 1- 8MP resolution,Shall be capable of live streaming & Storing 32 cameras, Shall support Net HDD, Storage up to 8 TB Surveillance HDD,Shall support audio, G.711A/G.711U, Shall support 1 E-sata port, 2x RJ45 10M/100M/1000M ports,Audio input 1 channel, Audio Output 1 channel output , Alarm input 16 channel, Alarm Output 1 channel output, USB2.0*1, USB3.0*1+USB2.0*1 port , RS485*1,Protocol :IPv4, IPv6, TCP/IP, HTTP, HTTPS, DDNS,RTMP, SMTP(SSL), SNMP, DHCP, PPPoE, UPnP,NTP, P2P, FTP , Simultaneously record multiple streams in any combination of H.264/H.265/H.264+/H.265+, support Start, stop, normal play, back play, frame by frame forward, full screen, Fast forward / backward (2x, 4x, 8x,16x), Slow forward (1/2x, 1/4x, 1/8x,1/16x), Add custom/ Default Tag for any events at the time of playback, digital zoom, video clip, sub stream/main-stream, playback video bar, Shall be able to take actions pre and post recording, Send email, show message, send email, FTP upload video or screenshot, Cloud upload video or screenshot, full screen, voice prompts, Alarm output trigger, PTZ linkage on events, support the display of VCA metadata on video live-view and and playback, Supports AI from camera side : Face Detection, Human Detection, Vehicle Detection, Perimeter Intrusion Detection, Line Crossing Detection, Cross Counting, Heat Map, Crowd Density Detection, Queue Length Detection, License Plate Detection, Rare Sound Detection, Stationary Object Detection, Sound Detection, Capable to show statistics and graphs of events for different interval of time search, Shall support S.M.A.R.T HDD function for HDD status,Onvif Support , Power Supply : DC12V/2A ,Consumption without HDD : 12W , Temperature : -10°C~+50°C (14°F ~ 122°F) Humidity : Less than 90%RH , 378*326*66mm (W×D×H) Dimensions ,Certificates:CE, BIS, FCC, ROHS and REACH. complete in all respects as approved and desired by the Engineer-in-charge at site.
826Supply, erection, testing & commissioning of Switches: 24 Ports 10/100/1000 Mbps PoE + 4 Ports 10G SFP+ Smart Managed Layer 2 Switch, Power budget 370W from day1, Support 802.3af/at), Switching Capacity 128 Gbps, MAC Address Table 16K, Packet Forwarding Rate, 95.24 Mpps, Flash Memory 64 MB, DRAM Size 256 MB DDR3, IGMP v1/v2/v3 Snooping & MLD snooping v1/v2, 802.3x Flow Control, HOL Blocking Prevention, LLDP/ LLDP-MED, 802.1D, 802.1W, 802.1s, 802.1Q, 802.1p QOS, SPQ, WRR, WDRR, Bandwidth Control, Static routing, IPv6 Neighbor Discovery (ND), ACL Max. 768 rules shared by IPv4, MAC, & IPv6, Traffic segmentation, ARP Spoofing Prevention, ARP Inspection, DHCP Snooping, MAC authentication, SSH v2, TLS v.1.2, DoS attack prevention, 802.1X Port-based Access Control, Port Security, RADIUS/TACACS+, MD5 authentication, GUI, Full CLI, Telnet Server, TFTP Client, MDI/MDIX, SNMP v1/v2c/v3. Internal/External 6 kV surge protection on all RJ-45 access ports, Operating Temperature -5 to 50°C, Storage Temperature -20 to 70°C, Operating Humidity 0% to 95% relative humidity, Certifiate: EMC EN 55032, Class A; EN 61000-3-2; EN 61000-3-3; EN 55024, Safety EN 62368-1, ROHS EN IEC 63000, 47 CFR FCC part 15: 2017, Subpart V, Class A, ICES-003, IEC 62368-1, IEC 60950-1, IEC 60950-1/AMD1, IEC 60950-1/AMD2, UL 62368-1 & CAN/CSA C22.2 No. 62368-1-14. MTCTE/TEC-ER (as notified vide Indian Telegraph (Amendment) Rules, 2017, OEM Should be ISO 45001, ISO 27001 & ISO 14001 Certified, OEM Should have Certificate for Industrial Cyber Security Capability (Like - IEC-62443-4-1:2018 or Equivalent) complete in all respects as approved and desired by the Engineer-in-charge at site.
827Supply, erection, testing & commissioning of 6000GB Audio Video HDD 3.5 Inches Connector SATA, Interface SATA, Operating Temperature 0°C to 65°C, Transfer Rate minimum 160MB/s, Recording Technology – CMR, Certifications BSMI, ICES-003/NMB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB- Scheme, TUV, UL for NVR recording and playbac complete in all respects as approved and desired by the Engineer in-charge at site.
828Supply, erection, testing & commissioning of Smart 55” LED Commercial Panel /Regular with 2 HDMI Port, TV Input, 3 Years Warranty, 2 HDMI Port, TV Input, 3 Years Warranty, Resolution 4K, Brightness 300 cd/m2 Support 4K Ultra HD 20 Watt 2.0 Audio Output Web Browser Soft AP, WiFi (bandwidth) Screen Share (Miracast) Samsung TV Plus App USB Cloning, 2 No. Of HDMI Port,2 no USB Port .complete in all respects as approved and desired by the Engineer-in-charge at site.
829Supply, Installation, Testing & Commissioning of 6 Mtr HDMI Cable for NVR, UL Listed complete in all respects as approved and desired by the Engineer in-charge at site.
830Supply, Installation, Testing and Commissioning of Wall Mount 15U x 600 W x 600 D ,Front Glass Door (tinted,Toughened) with Lock & Key, 2 pairs of 19\\" Mounting Rails with U-Marking , Welded Side Walls, Min Accessories : 1U Cable Manager (1), Hardware Packet (1 Pkt), 6 Socket 5 Amp. Power Distribution Unit (1 No), Roof Mounted Fan Unit / 90 CFM /230V AC.as per DIN 41494 Standards complete in all respect as per satisfaction of the Engineer in charge of the work.
831Supply, Installation, Testing & Commissioning of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respects as approved and desired by the Engineer in-charge at site.
832COPPER CONDUCTOR CABLES FOR SPECIAL ELECTRICAL SERVICES:Supply and erection of CAT 6 with 23AWG solid bare copper conductor, special grade PE insulation with star separator, 4pair Unshielded Twisted Pair (UTP) industrial cable, FR PVC sheathed, Class-E, 250 MHz of bandwidth, supporting data transfer speeds of up to 10 Gbps (10GBASE-T) for distances up to approximately 180 feet, cables are manufactured and tested to meet the ANSI/TIA 568-C.2 and ISO/IEC 11801 Class E standards left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
833CAT 6 LAN cable
834PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
835Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
836Providing Fire Detection/ Emergency Evacuation & PA System:
837FIRE PANELS & ANNUNCIATORS:
838Supply, installation, testing & Commissioning of Loop Cards Class A Wiring with min. supporting cable length Up to 1.2 Km UL & FM Approved complete in all respects as approved and desired by the Engineer in-charge at site. It includes the (CAMC of 2 Years after completion of one year defect liability period)
839Supply, installation, testing & Commissioning of Addressable photo-Thermal multi criteria Detector and base with sensitivity range as per NFPA 72. The intelligent detection device shall include the ability to combine the signal of the thermal sensor with the signal of the photoelectric signal in an effort to react hastily in the event of a fire situation. It shall also include the inherent ability to distinguish between a fire condition and a false alarm condition by examining the characteristics of the thermal and smoke sensing chambers and comparing them to a database of actual fire and deceptive phenomena. The detector shall have bi-colour LED for 360 deg viewing. Addressing shall be with user friendly rotary/ Electronic decimal switches. Designed to meet UL & FM Approved . The solution should be from single OEM complete in all respects as approved and desired by the Engineer in-charge at site. It includes the (CAMC of 2 Years after completion of one year defect liability period)
840Supply, installation, testing & Commissioning of Addressable Manual Call Point (Pull down / Break Glass Type). The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device complete in all respects as approved and desired by the Engineer in-charge at site. It includes the (CAMC of 2 Years after completion of one year defect liability period)
841Supply, installation, testing & Commissioning of Sounder cum Strobe rated at 80 dBA @ 3m for Audible annunciation and 115cd flashintg at 1 Hz for visual indication. UL Listed.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab complete in all respects as approved and desired by the Engineer in-charge at site. It includes the (CAMC of 2 Years after completion of one year defect liability period)
842Supply, installation, testing & Commissioning of Addressable Control Module for Sounders / Strobes / Sounder cum Strobes/ Telephone Jack. The control module shall provide supervised NAC output rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance complete in all respects as approved and desired by the Engineer in-charge at site. It includes the (CAMC of 2 Years after completion of one year defect liability period)
843Supply, installation, testing & Commissioning of Monitor Module for Sprinklers, Panic Bars & other Third Party Inputs. The monitor module shall monitor potential free contacts. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance. The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab complete in all respects as approved and desired by the Engineer in-charge at site. It includes the (CAMC of 2 Years after completion of one year defect liability period)
844Supply, installation, testing & Commissioning of Isolator Module for Isolating short / dewired / loose circuits with automatic resetting arrangement. Isolator Base can also be proposed, however in that case needs to be considered with each detector & module. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab complete in all respects as approved and desired by the Engineer in-charge at site. It includes the (CAMC of 2 Years after completion of one year defect liability period)
845Supply, installation, testing & Commissioning of Addressable Relay Module for AHU, Access Control, Lifts, Staircase Pressurization, Fire Suppression & other Third Party Outputs. The relay module shall provide contact rated at 24v DC, 2A. The device shall have an LED which shall blink in normal state & get steady on activation to monitor the heath status of the device. Addressing shall be with user friendly rotary decimal switches. Module shall be supplied with mounting plate from OEM for ease of installation & maintenance.The solution should be from single OEM. OEM should have manufacturing facility in India. OEM Should have presence in India from last 15 year. OEM should have own toll free number for service & support of product. Contactor shall off load the work to specialized agency having direct distributorship from OEM & distributor will have minimum 2 trained OEM certified engineers & distributor have its own registered office in Punjab complete in all respects as approved and desired by the Engineer in-charge at site. It includes the (CAMC of 2 Years after completion of one year defect liability period)
846Supply, installation, testing & Commissioning of Addressable Fire Fighter's Telephone Jack for two way communication between Remote Fire Fighter & Fire Command Center. Each Telephone jack should have separate address. complete in all respects as approved and desired by the Engineer in-charge at site. It includes the (CAMC of 2 Years after completion of one year defect liability period)
847Supply,installation, testing & Commissioning of Digital Audio Amplifier with transfarmer as per site requierment . Amplifier shall be capable of N:N/N:1 configuration and shall be dual channel capable of processing Two of 8 audio channels and a total of Min 95 W ( It may be 1 unit or Combination of Multiple units to achieve the Requirement) at 70.7 VRMS output along with necessary enclosures with local FFT Raiser. The Digital Audio Amplifier shall be fully monitored for fault and alarm reporting. The proposed Digital Audio Amplifiers shall be (Wall/Panel Mounted). Integrated 8 channel Digital Voice Evacuation System Controller (as per requierment) capable of broadcasting Evacuation Messages on the same peer-to-peer Network and 2 ways Communication capable of supervising all the speaker circuits with adequate zone control and accessories. Failure of Fire Panel CPU shall not result in failure of DVC/Amplifier operation. Products not having this feature must provide dedicated CPU for DVC. The Evacuation System Controller shall have FFT Risers to control and conference minimum 30 Telephones.. Amplifiers shall be distributed across the building/floor to manage the sound attenuation problem & for the best sound intelligibility. All amplifiers can be back up of minimum 5 hours using secondary power source(battery power/UPS power) complete in all respects as approved and desired by the Engineer in-charge at site. It includes the (CAMC of 2 Years after completion of one year defect liability period)
848Supply, installation, testing & Commissioning of 2W Multi-Tap (0.25W; 0.5W; 1W; 2W), Ceiling/Wall Mount Speakers. The speakers shall be of the same make as that of the Control Panel & Amplifiers. They shall be compatible with supplied Amplifiers and shall work on 70.7Vrms. UL Listed. Project specific OEM authorization required for executing agency complete in all respects as approved and desired by the Engineer in-charge at site. It includes the (CAMC of 2 Years after completion of one year defect liability period)
849Supply, installation, testing & Commissioning of Back box for speaker as per site requirement complete in all respects as approved and desired by the Engineer in-charge at site. It includes the (CAMC of 2 Years after completion of one year defect liability period)
850Supply, Installation, Testing and Comissioning of LED Glow Type EXIT Sign Board with minimum three hour backup, photo luminescent of size 300 mm x 250 mm x 1.5 mm rigid sheet signage containing Zink Sulphate as bare chemical class-1 material PSPA fixed on 3 mm acrylic sheet on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener including cost of labour & material required to complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. It includes the (CAMC of 2 Years after completion of one year defect liability period)
851Supply, Installation, Testing and Comissioning of industrial grade Emergency Exit Light with LED Sign 2 Language, inbuilt Battery: 12V,7AH, with min 4hours backup made of power coated Sheet Metal, work with AC 220v,50Hz(+/15%) and Battery Light Source: 9W x 2 nos LED Bulbs, Battery operating volts: 11V to 14V, Battery charger: Regulated constant volt constant current Battery charging Time: 7 to 8 Hrs (app) Power consumption: 10W(app) while charging, LED display diffuser: Red/Green acrylic transparent, Tiltable, Auto lights up while power failure complete the job in all respect up to the entire satisfaction of Engineer-in-Charge of work. It includes the (CAMC of 2 Years after completion of one year defect liability period)
852Supply and erection of fire survival cable for fire alarm & PA system with annealed stranded copper conductor, fire resistant mica tape wrapped (at 950°C for 180 minutes), XLPE insulated, LSHZ (low smoke & zero halogen) bedding, LSZH (low smoke & zero halogen) red outer sheath, galvanized steel wire armour, 600/1000 volts grade, Fire resistant to IEC 331 & BS7846 F2/BS6387 & CWZ, Acid gas emission to BS EN 50267 (IEC60754), smoke emission to BS EN 50268 (IEC61034) and flame propagation to BS EN 50265, BS EN 50266 (IEC 60332-3) left bare in pipe or casing or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-
853Fire Survival cable 2Coe x 1.5 sq.mm
854PVC INSULATED PVC SHEATHED FR ROUND FLEXIBLE COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated PVC sheathed FR (2Core) round flexible wire with copper conductor cable (ISI marked) confirm to IS:694/1990 left bare in pipe or on surface with cleats of suitable size complete in all respect as desired by the Engineer-in-charge:-
855Overall size 1.5sq.mm (48/0.20mm), 2Core
856HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:-
857HGW Conduit Pipe 25mm dia. (1.6mm thick) On Surface
858PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
859Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
860Providing PA System for Courts:
861Supply, Installation, Testing & Comissioning of Amplifier Power Output:100W Max. THD. Output Regulation:≤ 2 dB, no load to full load at 1kHz. Input Channels: 5 X Mic 0.65mV/4.7kΩ, 2 X Aux 100mV/470KΩ. Frequency Response: 50-15,000Hz ± 3dB. Signal to Noise Ratio: 60dB. Tone Controls: Bass: ±8dB at 100Hz, Treble: ±8dB at 10kHz. Output: Preamp 200mV/600Ω, Line 1V/1kΩ. Speaker Output: 4Ω,8Ω,16Ω,70V & 100V. Digital Player: MP3 Player wih USB, SD & MMC Card Reader, Bluetooth. Power Supply: AC:220-240V 50/60Hz, DC:12V(12V Car Battery). Power Consumption: AC: 250VA DC: 5.5A..complete in all respect as per satisfaction of the Engineer in charge of the work.
862Supply, Installation, Testing & Commissioning of Speaker Power Rating: 50W Max. Power Taps: 30/20/10W. Impedance/Voltage: 80Ω/100V. Frequency Response: 50-20,000Hz. SPL at 1KHz (1W/1m): 87dB. Speaker: Woofer 163mm (6 ½\\"), Tweeter 25mm (1\\"). Dimensions: W215 X H310 X D175 mm. Weight: 3.80Kg complete in all respect as per satisfaction of the Engineer in charge of the work.
863Supply, Installation, Testing & Commissioning of Mic Frequency Response: 100-15,000Hz, Impedance: 1000Ω, Sensitivity: 7.0mV/Pa. Power Source: 3V-9V DC. Overall Length: 460mm(18\\") complete in all respect as per satisfaction of the Engineer in charge of the work.
864Supply, Installation, Testing & Commissioning of Mic Stand Heavy Duty Base, XLR Connector, 10m Twin Core shielded , 6.3mm (¼\\") phone plug, On/Off Switch complete in all respect as per satisfaction of the Engineer in charge of the work.
865Supply, Installation, Testing & Commissioning of Mic Cabling (5 Mtr) with connector complete in all respect as per satisfaction of the Engineer in charge of the work.
866Supply, Installation, Testing & Commissioning of 1000VA LIT UPS/ Power Plant with SMF batteries having 30 Minutes backup time, Cold Start, 3 No. plug Indian style, Automatic Voltage Controller, Overload protection, Over charging Protection, 2 No. 12v 7Ah Batteries, Wide Input Range, Fan Less Cooling system, Transfer time less than 8ms,Audible Alarm etc. complete in all respects as approved and desired by the Engineer in-charge at site.
867PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-
868Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed
869Providing Flood Lighting:
870PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-
871Overall size 1.5sq.mm (Un-sheathed)
872XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- (For Flood Lights)
873Overall size 10sq.mm (3Core) Un-armoured (On-Surface)
874DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:-
875Double walled corrugated (DWC) HDPE pipe 63/51mm (outer/ inner dia.)
876SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:
877Supply and erection of M.S. Channel bracket made from 100mm x 50mm of length 600mm and height 600mm with M.S. angle iron 40mm x 40mm x 5mm for installing metal halide flood light fitting on it. Bracket should be fixed/ welded with the existing pipe of cover shed. The bracket should be painted with one coat of primer and two coats of approved paint. (For Flood Lights on Parapet wall)
878Supply and erection of SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772 (Recessed/ On surface), robustly constructed, safe & shock proof, rust & tamper proof of suitable inner & outer dimensions with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB's) complete in all respect as approved and desired by the Engineer In-Charge at site:-
879SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirm to IS:14772, inner dimensions 200mm x 140mm x 95mm with hinged water tight cover with locking arrangement (For Flood Lights on Parapet wall).
880GALVANIZED IRON PIPES AND G.I. EARTHING:Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling).(For Cubical Pedestal)
881Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length)
882Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface)
883Supply and erection of heavy duty brass single compression gland for cable end termination duly complete with checknuts etc. including making necessary connections:-
884Brass Gland for Aluminium cable 2/3/4 Core size 10sq.mm
885Supply and erection of heavy duty aluminium thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-
886Aluminium thimble cable Core size 10 -16sq.mm
887SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:CUBICAL PEDESTAL: Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should be filled with 1:2:4 cement concrete mixture and erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:-
888Cubical Size 1200mm high, 900mm wide and 350mm deep with platform dimensions 1000mm x 450mm x 450mm
889MS SHEET ENCLOSURE FOR MCCB's:Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shall be made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/top with cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:-
890MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm)
891MCCB's (MOULDED CASE CIRCUIT BREAKER):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:- (For X-Ray Room)
892MCCB Four Pole 63amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting
893TIMER:- Supply and erection of Switch S/E of Microprocessor Based Street Light Controller with digital time switch daily programmed with stand by lithium battery with back up of 6 years with min. time between 2 switching operations is 1 minute, three pole power contactors 40A. with coil voltage 220-230V AC with 1 no. aux. contact NO, MCB 2 pole 40amp. (C-Curve, 10kA) & power wiring with single core PVC insulated FR cable 10 sq. mm and control wiring with PVC insulated FR cable 1 sq. mm, 1 no. two position selector switch to bypass timer and other accessories & petty material (din rail, 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts) should be fixed on bakelite sheet 6mm thick to be mounted in a IP54 surface/ flush mounting powder coated sheet metal (1.60mm thick) cabinet having size 450mm x 600mm x 150mm to switch ‘ON’ all the 3 phases & switch ‘OFF’ 3 phases pre-fixed timings complete in all respect as per satisfaction of Engineer-in-charge:-
894Street Light Controller (For Three Single Phase Circuits) with 3 Nos. Three Pole Power Contactors 40A, 1 no. aux. contactor 6 amp. (2NO+2NC) with coil voltage 220V AC, 3 Nos. MCB 2 Pole 40amp. (C-Curve,10kA) & petty material (Din rail, 2 Nos. 4 pole bakelite terminal strip 63A/ 440V AC, required nut bolts)
895Supply and erection of LED Flood Light 120 watt, AC supply voltage 140-270 volts, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED (with wattage 1 to 5 watt) with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No: AT/2021/GL/1410-1422 Dated: 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
896Supply and erection of LED Post top 40/45 watt Opal Diffuser Supply Voltage 140-270Volts AC supply, 50Hz ± 3% (including BIS Certified potted single diver with screen or laser printing logo LED driver) with pressure die cast or extruded aluminium housing with control gear (IP 66 protection), THD<10%, CRI minimum 70, High power LED with wattage 1 to 5 Watt with mandatory secondary lenses, toughened glass fitting, 4 KV SPD within driver and 10KV external SPD, Min IK07, efficacy of LED fixture minimum 120 lumens per watt, 5 year warranty including their drivers complete in all respects as approved and desired by the Engineer in-charge at site. LED Fittings as per specifications approved by Hon'ble Technical Advisor to Punjab Govt. vide Letter ION No:- AT/2021/GL/1410-1422 Dated:- 06.05.2021. Besides this the lighting fixtures manufacturers should have in house NABL accredited lab.
897Providing Solar Power Generation System:
898Grid interactive PV System Solar Power Plant of 120KWp:
899Supply, Installation, testing & Commissioing of Grid interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimumcapacity including required quantities of SPV modules (High power density bifacial monocrystalline solar modules with a capacity of +400 watts) formed into arrays, their mounting arrangement, Power conditioning units (i.e String Solar Inverter with 2Nos. GI Chemical earthing with suitable size GI strip upto string inverter and AC & DC distribution panel), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board through Cable tray, Bi Directional Energy Meter, Provision of Lightening Arrestor & 2 Nos. GI chemical earthing with suitable size GI strip upto Lightning arrestor, Hot dip galvanized MS Mounting Structures (1No. GI Chemical earthing with suitable size GI strip upto mounting structure) should be designed to withstand the speed for the wind Zone of the location (150 Km/hr-170 Km/hr) Complete in all respect with transportaion, fabrication, labour & Civil Work etc. Features :- 1. Solar PV Module warranty 25 Years & certified under IS/IEC 61730 I & II IS/IEC 61701 & IS/EC 142862. Power Conditioning unit (string solar inverter) & certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 605293. Structure 25 Years service life with AMC & certified under IS 2062 20114. Complete Plant insurance for the period of 5 Years (Excluding Theft of the Material)5. Annual Maintenance contract for the period of 10 YearsConditions:# The Plant will be installed as per MNRE and GOI guidelines and specifications. (Detail of material as per Annexure-I attached)#The work will got done from approved MNRE (Misitry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) contractor/P.W.D enclosed contractor subject to connection that he will got workdone from Peda/NV#The capacity of solar power plant my increase or decrees as availability of site it can also be totally removed from executive endThe Rate are inclusive of B1 directional metere testing charges PSPCL connection charges unidirectional meter etc and all type of taxes including GST Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56936108
AUTHORITY Government Departments
TENDER VALUE 8.22 Crore
LAST DATE 25-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of 2 Nos Permanent Courts At Second Floor Of Judicial Block In Jcc At Baba Bakala Sahib Distt: Amritsar (Punjab)
Basic Detail
Tender No EE/PD/Asr/08 dated 04.08.2026
Bidding Type Tender
Location
City Amritsar
State Punjab
Key Dates
Publish Date 11 Aug 2026
Submission Date 25 Aug 2026
Open Date 26 Aug 2026
Finance
Tender Value 8.22 Crore
Tender Fee 30000
EMD 16.44 Lakhs
Exemption Available
Document List
bee245a0-b7f6-4b02-8a90-1179d89070e3.html
BOQ_352722.xls
Drawings.pdf
sbbbd_compressed.pdf
Tendernotice_1 (11).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 11, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Aug 26, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

bee245a0-b7f6-4b02-8a90-1179d89070e3.html

xls

BOQ_352722.xls

pdf

Drawings.pdf

pdf

sbbbd_compressed.pdf

pdf

Tendernotice_1 (11).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders