Tender For Up-Gradation Of Dic Office Building Pulwama Including Construction Of Additional Block Pulwama.
Tender Value
36.52 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
8 days left
EMD
73040
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pulwama → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Up-Gradation Of Dic Office Building Pulwama Including Construction Of Additional Block Pulwama.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 11-Aug-2026 | Correction | Other | 31-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in bulk excavation by manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil |
| 2 | P/L of stone soiling hand packed incl. carriage |
| 3 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size |
| 5 | Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 6 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns etc. for mass concrete. |
| 7 | Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand) |
| 8 | 15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand) |
| 9 | Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick |
| 10 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade on New work (two or more coats) over and including priming coat with water thinnable cement primer |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth levelThermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): First class kail wood |
| 13 | Providing and fixing wire gauze shutters using galvanized M.S. wire gauze of average width for aperture 1.4 mm in both directions with wire of dia. 0.63 mm for doors, windows and clerestory windows with ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws as per direction of Engineer-in-charge 35mm First class kail wood |
| 14 | Providing and fixing glazed shutters for doors, windows and clerestory windows using 4mm thick float glass panes including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws. 35mm First class kail wood |
| 15 | Providing and fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0mm thick glass panes |
| 16 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, including panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. 35mm First class kail wood |
| 17 | Dismantling of existing ply board partion incl. stacking of serviceable material and disposal of unserviceable material out side municipal limit |
| 18 | Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20 mm nominal size stone aggregate. |
| 19 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm |
| 20 | Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded |
| 21 | Providing corrugated high ribbed colour coated CGI roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gram/m2(0.50mm thick) |
| 22 | Providing ridges or hips of width 60cm overall width plain G.S. sheets fixed with polymer coated J. or L hooks, bolts and nuts 8mm dia G.I. limpet and bitumen washers complete. 0.50 mm thick with zinc coating not less than 275 gram/m2 |
| 23 | Finishing walls with acrylic smooth exterior paint of required shade on New work (Two or more coats applied @ 1.67 liter/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm) |
| 24 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture inc;uding priming coat. |
| 25 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar |
| 26 | Providing and laying inter locking cement concrete tile of thickness 80mm laid on 20mm thick cement mortar of mix 1:4 iincluding and cushioning. |
| 27 | P/F OF Doors, Windows and partition made of colour coated aluminium of different size with 12 mm thick prelaminated board and 5mm thick glass with hardware fitting |
| 28 | Wiring for the following light points with 1.5Sqmm PVC insulated copper conductor 1100 volts grade standard flexible FRLS wires of approved make in concealed or surface mounted PVC conduit including providing and fixing of 6 Amp single pole rocker operated flush mounted switch of approved quality, color make and design in 1.6mm thick GI box and earthing of fixtures and the outlet box with 1.5sqmm PVC insulated copper conductor stranded flexible FRLS wire.a). One light controlled by 6 Amp Switch . |
| 29 | Wiring for 250 volts single phase and neutral 16 Amps switched socket outlet with 4 Sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires in concealed or Surface mounted 25mm dia 2mm thick PVC conduit including providing and fixing of 16 Amps 3 pin switched socket of approved make and design in 1.6mm thick G1 boxes with grid plates and earthing the third pin of socket outlet with 4 Sq.mm PVC insulated copper conductor stranded flexible FRLS wire. |
| 30 | Wiring for 230v ac, 5pin 5/6 amps switched socket outlets for light duty power with 230v ac 5/6amps, SP switch and socket, on same modular grid plate mounting with 2x2.5sqmm stranded copper conductor FRLS insulated 1100v grade wire in 25mm dia, 1.6mm thick rigid MS conduit/Pvc with earthing of 3rd pin by 1/1.5 sq mm stranded copper conductor FRLS insulated green 1100v grade wire with lug complete. |
| 31 | Wiring for ceiling/wall Fan points same as above in item No 28. but controlled by electronic stepped regulator 200 watts and 5A control switch and 15mm dia circular or hexagonal in 1.6mm thick MS zinc passivity sheet steel body and 12mm dia MS bar hook complete with white ,3mm thick 200mm dia laminated circular cover |
| 32 | Supplying installation testing and commissioning of exhaust fan complete connection as required |
| 33 | Supplying installation testing and commissioning of cellingfan/Wall Fan (as per requirement at site) Crompton Usha or equelent make. |
| 34 | Supplying installation testing and commissioning of 10 watt slim round LED light of approved make complete fitting as required. |
| 35 | Supplying installation testing and commissioning of bulk head with 10 watt led light complete fitting as required |
| 36 | Supplying and fixing of lighting indicators |
| 37 | Supplying and fixing of two pin socket |
| 38 | Supplying installation testing and commissioning of industrial socket with 32 Amp double pole MCB |
| 39 | Supplying and installation testing and commissioning following ways of TPN DB boxa) 6 Way TPN DB board |
| 40 | Supplying and installation testing and commissioning of following mccb,sa)25 to 32 amp mcbSp |
| 41 | B)32 Amp TPN |
| 42 | C)32 Amp DP |
| 43 | Wiring for circuits for light/fan/bells/exhaust fans/ AC’s etc with following size PVC insulated 1100v Grade multi strand copper conductor wire, green insulated multi strand copper conductor for earth wire in the existing conduits complete including connections all the three wires for phase, neutral and earth shall have to be taken to switch board and then distributed further. (without PVC, Conduits)a) ) 2x2.5+1x2.5 Sq.mm stranded copper PVC insulated for lighting circuits |
| 44 | b)2x1.5sq mm for inverter circuits |
| 45 | c)2x 6 Sq mm +1x2.5 Sq mm stranded copper conductor FRLS PVC insulated for AC circuits |
| 46 | Supplying and laying of sub main wiring from panel to distribution boards a)4x10 Sq. mm +2x6 Sq mm stranded copper conductor FRLS PVC insulated for heating circuits |
| 47 | b)4x 6 Sq mm +1x2.5 Sq mm stranded copper conductor PVC insulated for lighting circuits |
| 48 | Supply and fixing of 2mm thick PVC conduits/PVC channel in following sizes include cost of junction boxes, bends, elbows, sockets, tees etc. Including all fixing hardware. a). 25mm dia |
| 49 | b)35mm dia |
| 50 | Removing of old electric fitting including wiring switch boards conduit complete as per site including its disposal. |
| 51 | Design fabrication assembling supply installation testing and commissioning of LT sub main panel suitable for 415 V 3 phase 50 HZ 4 wire power supply system panel shall be fabricated out of 2mm thick CPCA sheet steel in cubical formation compact mobilize in form 3d construction wall mounted and shall be dust and vermin proof 3mm thick cable gland plate shall be provided both at the top and bottom of the panelMCCB 250 Amp 01 NoMCCB 100 Amp 02. NoBUS bar 200 Amp 02 setCT Coil 02 SetVoltmeter Digital 01 NoAmmeter Digital 01 NoIndication lights 02 sets Changeover 200 Amp 01 No |
| 52 | Rate for chemical earthing using electrode of size 50mm dia 2 meter long connected with 32x4mm GI internal strip complete with excavation, civil works, RCC cover with back fill compound. The voltage between neutral and earth not to exceed 2 volts. |
| 53 | Supplying and laying of 95Sq mm 3.5 core Al Armored cable of havelles make |
| 54 | Supplying and laying of 50Sq mm 3.5 core Al Armored cable of havelles make |
| 55 | Supplying installation testing and commissioning of AC points with industrial socket including 32 Amp double pole MCB Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 11, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Aug 31, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 8 daysAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer