Tender For Repair And Renovation Of 8Nos. Four Storied Us Qtr. Block Total 64 Qtr. At Lichubagan Police Housing Complex Under Hpc.(Balance Work).
Tender Value
59.17 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
6 days left
EMD
1.18 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Repair And Renovation Of 8Nos. Four Storied Us Qtr. Block Total 64 Qtr. At Lichubagan Police Housing Complex Under Hpc.(Balance Work).
BOQ
| Sl. No. | Item Description |
| 1 | Civil worksStripping off worn out plaster and raking out joints of walls, celings etc. upto any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 2 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof. Ground floor |
| 3 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof.1st Floor |
| 4 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof.2nd Floor |
| 5 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof.3rd Floor |
| 6 | Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed within a lead of 75 m. including stacking of steel bars. (a) In ground floor including roof. Mumpty Room |
| 7 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. (a) upto 150 mm. thick Ground floor |
| 8 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. (a) upto 150 mm. thick1st Floor |
| 9 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. (a) upto 150 mm. thick2nd Floor |
| 10 | Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. (a) upto 150 mm. thick3rd Floor |
| 11 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof. Ground floor |
| 12 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.1st Floor |
| 13 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.2nd Floor |
| 14 | Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. a) In ground floor including roof.3rd Floor |
| 15 | Removalof rubbish,earth etc.from the working site and disposal of thesame beyond the compound ,inconformity with the Municipal/Corporation Rules for such disposal,loading in to truckand cleaning the site in all respect as per direction of Engineer in charge |
| 16 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.a) Depth of excavation not exceeding 1,500 mm. |
| 17 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation. |
| 18 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominalsize) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes.Pakur Variety |
| 19 | 6 (b) Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade (i) Pakur Variety GROUND FLOOR |
| 20 | 6 (b) Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade (i) Pakur Variety FIRST FLOOR |
| 21 | 6 (b) Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade (i) Pakur Variety SECOND FLOOR |
| 22 | 6 (b) Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade (i) Pakur VarietyTHIRD FLOOR |
| 23 | 6 (b) Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture](b) M 25 Grade (i) Pakur VarietyMUMPTY ROOM |
| 24 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4 m (i) Tor Steel / Mild Steel ( I ) SAIL / TATA / RINL GROUND FLOOR |
| 25 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4 m (i) Tor Steel / Mild Steel ( I ) SAIL / TATA / RINL FIRST FLOOR |
| 26 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4 m (i) Tor Steel / Mild Steel ( I ) SAIL / TATA / RINL SECOND FLOOR |
| 27 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4 m (i) Tor Steel / Mild Steel ( I ) SAIL / TATA / RINLTHIRD FLOOR |
| 28 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor / upto 4 m (i) Tor Steel / Mild Steel ( I ) SAIL / TATA / RINL MUMPTY ROOM |
| 29 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF a) 25mm to 30mm thick wooden shutter ing as per decision and direction of E.I.C GROUND FLOOR |
| 30 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF a) 25mm to 30mm thick wooden shutter ing as per decision and direction of E.I.C FIRST FLOOR |
| 31 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF a) 25mm to 30mm thick wooden shutter ing as per decision and direction of E.I.C SECOND FLOOR |
| 32 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF a) 25mm to 30mm thick wooden shutter ing as per decision and direction of E.I.CTHIRD FLOOR |
| 33 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF a) 25mm to 30mm thick wooden shutter ing as per decision and direction of E.I.CMUMPTY ROOM |
| 34 | Brick work with 1st class bricks in cement mortar (1:6) in (a) In foundation and plinth |
| 35 | Brick work with 1st class bricks in cement mortar (1:6) in (b) Ground Floor Superstructure |
| 36 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in Ground floor |
| 37 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in 1st Floor |
| 38 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in 2nd Floor |
| 39 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in 3rd Floor |
| 40 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in Parapet wall |
| 41 | Labour for Chipping of concrete surface before taking up Plastering work. |
| 42 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sqm & joint filling using white cement slurry @ 0.20kg/Sqm(b) Area of Each tile upto 0.09 Sqm(i) Coloured decorative Ground floor |
| 43 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sqm & joint filling using white cement slurry @ 0.20kg/Sqm(b) Area of Each tile upto 0.09 Sqm(i) Coloured decorative1st floor |
| 44 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sqm & joint filling using white cement slurry @ 0.20kg/Sqm(b) Area of Each tile upto 0.09 Sqm(i) Coloured decorative 2nd floor |
| 45 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sqm & joint filling using white cement slurry @ 0.20kg/Sqm(b) Area of Each tile upto 0.09 Sqm(i) Coloured decorative 3rd floor |
| 46 | Making one set of scaffolding only for replacing glass panels, painting, uprooting plant and another repairing works of building and S&P works for external works only with 10 cm. dia bamboo as main posts at the rate of 1 metre centre to centre and 7.5 cm. dia bamboo ties @ 0.75 metre apart fitting and fixing with necessary coir, nails etc. as per direction of the Engineer-incharge. (This item should be executed only after prior approval of the Engineer-incharge). Firstly, one number to be paid and then labour rate for shifting up to further nineteenth (19) times @ 10% Each time to be considered. If necessaryfurther after twenty times of total use, another one number new and labour rate for shifting to be considered accordingly a) 3.90 metre height |
| 47 | Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor. Slab thickness 20 to 25 mm Ground floor |
| 48 | Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor. Slab thickness 20 to 25 mm 1st Floor |
| 49 | Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor. Slab thickness 20 to 25 mm 2nd Floor |
| 50 | Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor. Slab thickness 20 to 25 mm 3rd Floor |
| 51 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii)With 1:4 cement mortar, c) 15 mm thick plaster. Inside included Ceiling Plaster Ground floor |
| 52 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii)With 1:4 cement mortar, c) 15 mm thick plaster. Inside included Ceiling Plaster1st floor |
| 53 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii)With 1:4 cement mortar, c) 15 mm thick plaster. Inside included Ceiling Plaster 2nd floor |
| 54 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii)With 1:4 cement mortar, c) 15 mm thick plaster. Inside included Ceiling Plaster 3rd floor |
| 55 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii)With 1:4 cement mortar, c) 15 mm thick plaster. Inside included Ceiling PlasterMumpty Room |
| 56 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]i)With 6:1 cement mortar b) 20mm thick plaster OUTSIDE Ground floor |
| 57 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]i)With 6:1 cement mortar b) 20mm thick plaster OUTSIDE1st floor |
| 58 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]i)With 6:1 cement mortar b) 20mm thick plaster OUTSIDE 2nd floor |
| 59 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]i)With 6:1 cement mortar b) 20mm thick plaster OUTSIDE 3rd floor |
| 60 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]i)With 6:1 cement mortar b) 20mm thick plaster OUTSIDEMumpty Room |
| 61 | Neat Cement Punning above 1.5mm thick in Wall dado,Window Sill Floor and Drain etc Note Cement 0.152 cum 100 SqMts Ground floor |
| 62 | Neat Cement Punning above 1.5mm thick in Wall dado,Window Sill Floor and Drain etc Note Cement 0.152 cum 100 SqMts1st Floor |
| 63 | Neat Cement Punning above 1.5mm thick in Wall dado,Window Sill Floor and Drain etc Note Cement 0.152 cum 100 SqMts 2nd floor |
| 64 | Neat Cement Punning above 1.5mm thick in Wall dado,Window Sill Floor and Drain etc Note Cement 0.152 cum 100 SqMts3rd floor |
| 65 | Removing old paint from blistered painted surface of steel or other metal by chipping including scraping and cleaning and exposing the original surface |
| 66 | Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc |
| 67 | A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. Including using of approved putty etc. on the surface, if necessary :(b) On Steel or other metal surface. With other than hi-gloss of approved quality- iv) Two coats (with any shade except white) |
| 68 | Priming one coat on timber or plastered surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 69 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary :On timber or plastered surface.With super gloss (hi-gloss) -Two coats (with any shade except white) |
| 70 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC. (In Ground Floor)i) Water based interior grade Acrylic Primer (a) One Coat All floor |
| 71 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(a) two Coat Ground floor |
| 72 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(a) two Coat1st Floor |
| 73 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(a) two Coat2nd Floor |
| 74 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(a) two Coat3rd Floor |
| 75 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer's specification and as per direction of the EIC.(a) two CoatMumpty Room |
| 76 | Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturer's specification) including cleaning and smoothning of surface.Two CoatsAll floor |
| 77 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Normal Acrylic Emulsion (Two Coat)In Ground floor |
| 78 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Normal Acrylic Emulsion (Two Coat)In First floor |
| 79 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Normal Acrylic Emulsion (Two Coat)In Second floor |
| 80 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Normal Acrylic Emulsion (Two Coat)In Third floor |
| 81 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer's specification and as per direction of Engineer-in-Charge to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost of primer.a) Normal Acrylic Emulsion (Two Coat)In Mumpty Room |
| 82 | Scraping of moss, blisters etc.thoroughly from exterior surface of walls necessitating the use of scraper, wire brush etc.(Payment against this item will be made only when this has been done on the specific direction of the Engineer-in-charge)All floor |
| 83 | Scraping and removing greasy soot from walls or ceiling of kitchen or similar smoke affected rooms and preparing the surface.All floor |
| 84 | Labour for taking out door and window frame including shutter for repair or replacement of different parts of the frame & refixing the same including mending good all damages complete. (Concrete and brick work for mending damage will be paid separately) upto 2.5 Sqm |
| 85 | a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./SqMeter upto 16kg/SqMeterGROUND FLOORWindow & Balcony Railling |
| 86 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) (ii) 4 mm thick |
| 87 | Extra for fixing glass panes in steel window |
| 88 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). (e) Sal : Malayasian |
| 89 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wide Each and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneers using phenol formaldehyde as glue etc. complete, including fitting, fixing shutters in position but excluding the cost of hinges and other fittings in ground floor.(a) 35 mm thick shutters (single leaf) |
| 90 | Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multichamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastner/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete. |
| 91 | Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC âCâ channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the âCâ channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in- Charge. Ground floor |
| 92 | Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC âCâ channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the âCâ channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in- Charge.1st floor |
| 93 | Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC âCâ channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the âCâ channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in- Charge.2nd floor |
| 94 | Supplying, Fitting & Fixing 30 mm thick both side prelaminated Factory made solid Panel PVC Door Shutter consisting of outer frame made out of M.S. tubes of 19 gauge thickness and size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have cost of steel primers of approved make and manufacture, M.S. frame covered with 5 mm th. heat moulded PVC âCâ channel of size 30 mm th, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on either sides forming styles; and 5 mm th. 95 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm tapered in 45 degree on the inner side to form top & bottom rail and 115 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided either side of the panel with 10 mm (5mmx2) th.,20 mm wide cross PVC sheet as gap insert for top rail and bottom rail sheet to be fitted in the M.S. frame welded/sealed to the styles &rails with 7 mm (5 mm+2 mm) th.x15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm th. PVC strip of 20 mm which is to be stuck on the interior side of the âCâ channel using PVC solvent adhesive etc. complete excluding all necessary hardwares as per direction of Engineer-in- Charge.3rd floor |
| 95 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal / Round rod) (v) 125 mm grip x 12 mm dia rod. |
| 96 | (v) Two point nose aluminium handle including fitting and fixing. |
| 97 | (vi)steel peg stay 300 mm long including fitting and fixing. |
| 98 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately). (a) 40mm X 6mm, 250mm Length |
| 99 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark 100mm X 50mm X 1.25mm |
| 100 | i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.250mm long |
| 101 | (ii) Door stopper (Anodised aluminium) |
| 102 | Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. (iii) 100mm long x 10mm dia. bolt. |
| 103 | Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. (vi) 200mm long x 10mm dia. bolt. |
| 104 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. In ground floor |
| 105 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] |
| 106 | SANITARY & PLUMBING WORKSSupply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Meter Length(a) 75 mm |
| 107 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Meter Length(b) 110 mm |
| 108 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Meter Lengthc) 160 mm |
| 109 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(i) Coupler(a) 75 mm |
| 110 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(i) Couplerb) 110 mm |
| 111 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(i) Couplerc) 160 mm |
| 112 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(ii) Plain Tee(a) 75 mm |
| 113 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(ii) Plain Teeb) 110 mm |
| 114 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(ii) Plain Teec) 160 mm |
| 115 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(iii) Door Tee(a) 75 mm |
| 116 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(iii) Door Teeb) 110 mm |
| 117 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(iii) Door Teec) 160 mm |
| 118 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsiv) Door Tee(LH) & (RH)(a) 75 mm |
| 119 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsiv) Door Tee(LH) & (RH)b) 110 mm |
| 120 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsv) Plain Y(a) 75 mm |
| 121 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsv) Plain Yb) 110 mm |
| 122 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsv) Plain Yc) 160 mm |
| 123 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsx) Bend 87.5º(a) 75 mm |
| 124 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsx) Bend 87.5ºb) 110 mm |
| 125 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsx) Bend 87.5ºc) 160 mm |
| 126 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxi) Door Bend (T.S.)(a) 75 mm |
| 127 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxi) Door Bend (T.S.)b) 110 mm |
| 128 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxi) Door Bend (T.S.)c) 160 mm |
| 129 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxiv) Cross Tee with Door(a) 75 mm |
| 130 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxiv) Cross Tee with Doorb) 110 mm |
| 131 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxv) Vent Cowl(a) 75 mm |
| 132 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxv) Vent Cowlb) 110 mm |
| 133 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxv) Vent Cowlc) 160 mm |
| 134 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxvi) Pipe Clip(a) 75 mm |
| 135 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxvi) Pipe Clipb) 110 mm |
| 136 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxvi) Pipe Clipc) 160 mm |
| 137 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxxxi) Plain Floor Trap with Top tile & Strainer75 mm |
| 138 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxxiii) 110/110 S Trap75 mm |
| 139 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxxvi) Reducer 110 X 75 mm75 mm |
| 140 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxxvii) Reducing Tee (110 X 75 mm)75 mm |
| 141 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxviii) W.C. Connector (450 mm long) W / lipring75 mm |
| 142 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittingsxxi) 110 X 110 P Trap75 mm |
| 143 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) FittingsxIv) Round Jali 75 mm |
| 144 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) FittingsxIvi) Door Capa) 75 mm |
| 145 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) FittingsxIvi) Door Capb) 110 mm |
| 146 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)50mm |
| 147 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)32mm |
| 148 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)25mm |
| 149 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)20mm |
| 150 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)15mm |
| 151 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.550 mm X 400 mm size |
| 152 | Dismantling wash basin with brackets with or without waste fittings. |
| 153 | Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc.With 'P' trap (without vent) |
| 154 | Dismantling Indian W.C. including taking out base concrete as necessary. |
| 155 | Refixing Indian W.C. excluding cost of base concrete if necessary complete. |
| 156 | Dismantling E.P. or Anglo-Indian W.C. |
| 157 | Dismantling Orissa pattern W.C. including taking out of base concrete, ifnecessary, complete. |
| 158 | Cleaning E.P. or Anglo-Indian W.C. with acid. |
| 159 | Cleaning urinal with channel with acid. |
| 160 | Removing chokage of water closet. |
| 161 | Removing chokage of urinal and waste trap. |
| 162 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete.Polythene Flush Pipe |
| 163 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. 900 mm long |
| 164 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.1050mm long |
| 165 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
| 166 | Supplying, fitting and fixing low-down cistern parts.(i) Internal fittings for cistern complete of approved make. |
| 167 | Supplying, fitting and fixing low-down cistern parts.(ii) Outlet Assembly |
| 168 | Supplying, fitting and fixing low-down cistern parts.(iii) Intlet Assembly |
| 169 | Supplying, fitting and fixing low-down cistern parts.(iv) Rubber Kid |
| 170 | Supplying, fitting and fixing low-down cistern parts.(v) Knob |
| 171 | Supplying, fitting and fixing low-down cistern parts.(vi) Brackets (pair) |
| 172 | Supplying, fitting and fixing low-down cistern parts.vii) CP Flush Bend (local) best qualitya) Orrisa & Indian Pattern WC |
| 173 | Supplying, fitting and fixing low-down cistern parts.vii) CP Flush Bend (local) best qualityb) E. W.C. & Anglo-Indian W.C. |
| 174 | Renewing bolts and nuts for cistern. |
| 175 | Supplying, fitting and fixing bib cock or stop cock.Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / SuMthing Special of ESSCO or similar brand). |
| 176 | Supplying, fitting and fixing bib cock or stop cock.PTMt (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent) 15 mm |
| 177 | Supplying, fitting and fixing pillar cock of approved make. b) PTMt Pillar Cock - 15 mm. (Prayag or equivalent). |
| 178 | Dismantling pillar cock of wash basin. |
| 179 | Refixing pillar cock of wash basin. |
| 180 | Fixing brackets for wash basin/ sink/ drain board/ cistern. |
| 181 | Supplying, fitting and fixing soap holder.PTMt (Prayag or equivalent) |
| 182 | Supplying, fitting and fixing PTMt Smart Shelf of approved make of size 300 mm. |
| 183 | Supplying, fitting and fixing towel rail with two brackets.C.P. over brassiii) 25 mm dia. and 750 mm long |
| 184 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm |
| 185 | Supplying, fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of C.I. brackets.Sink only530 mm X 430 mm x 180 mm |
| 186 | Dismantling sink with brackets with or without waste fittings.(ii) Above 450 mm and upto 600 mm length |
| 187 | Refixing sink with brackets with or without waste fittings.(ii) Above 450 mm and upto 600 mm length |
| 188 | Cleaning wash basin/ sink with acid. |
| 189 | (g) PTMt overhead shower ( Prayag or equivalent)(ii) 150 mm round |
| 190 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer2000 Litre capacity |
| 191 | Labour for hoisting plastic water storage tank.Above 1500 litre upto 5000 litre capacityOn the roof of muMty(top of forth floor) |
| 192 | Labour for punching hole in plastic water storage tank upto 50 mm dia. |
| 193 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.i) With Pakur variety. (SAIL/TATA/RINL) |
| 194 | Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed.Upto 50 users:-Within a lead of 150 metre |
| 195 | Cleaning silt of inspection pit. |
| 196 | Dismantling & Refixing pit cover |
| 197 | Cleaning rubbish, sludge, weeds scum, liquid earth, mud etc.etc.from road side masonary drain/ hume pipe drain/ culvert etc. by mathor labour after removing concrete.Slab/manhole cover etc.without damaging the same and refixing the same properly after cleaning as necessary and removing the sludge etc.etc.by using iron pans,buckets including all labour, tools & plants including removing the spoils in dry condition and disposing the same by truck beyond the road side in conformity with municipal/corporation rules for such disposal including loading into truck and cleaning the road side in all respects as per direction of the Engineerin- Charge. (Payment will be made on the basis of actual stack measurment of spoils in dry condition at roadside) |
| 198 | Supplying, fitting and fixing in position C.I. manhole/ pit cover with rim.a) Round(i) 450 mm X 100 mm X 21 kg (approx.) |
| 199 | Cleaning soak pit by removing the top slab and replacing inner filling with jhama bats and repairing the pit as necessary including fitting the slab. |
| 200 | Cleaning silt of master trap pit. |
| 201 | Taking out old damaged tarfelt from the roof, parapet etc. preparing the roof surfaces by removing all spoils, blisters, moss etc. from the working site and disposal of the same beyond the compound and cleaning the site in all respect as per direction of Engineer-in-Charge. All Floors |
| 202 | (b) Applying 2 coats of Non-Toxic Acrylic Polymer modified Paint having adhesive & waterproofing properties by mixing in proportion (1 liquid: 4 cementitious material) or as per manufacturer's specification for water proofing layer in water tank etc. (No Departmental Cement is required) |
| 203 | Cutting chase upto 125 x 150 mm. and subsequent mending of damages.(a) in brick wall [Cement-3.6 Kg/Mtr] |
| 204 | Cleaning the concrete surface by removing dirt and debris, marking defective locations and removing loose concrete by careful stripping untill hard surface is exposed, cutting the concrete to regular shape, wire brushing the exposed surface and removing debris from site complete as per direction of the Engineer - in - Charge. ALL FLOORS |
| 205 | Cleaning the exposed reinforcement preferably upto full diameter by wire brush, applying two coats of polymer based rust removing compound left for 24 hours, removing the coating and then applying two (2) coats of polymer modified anti corrosive protective coating formulated to inhibit the corrosion of reinforcement as per manufacturer's specification] [Mode of measurement:The affected surface area of reinforcement shall be considered for payment] |
| 206 | Cement concrete (1:1.5:3) with graded stone chips 5.6 mm size with hexagonal square mesh wire netting, I.R.C. fabric mesh or X.P.M. fitted and fixed after tying the existing reinforcement on concrete without distributing the same and with proper scarping and cleaning the reinforcement and disturbed concrete with wire brush etc. after applying a coat of cement including the cost of wire netting I.R.C or X. P. M. & cost of all handling and scaffolding complete as per direction of Engineer-in -charge.37.5 mm thick |
| 207 | Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure, 3rd floor |
| 208 | Brick work with 1st class bricks in cement mortar (1:6) (b) In superstructure,Mumpty |
| 209 | Supplying, fitting and fixing Orissa pattern water closet in white glazedvitreous chinaware of approved make in position complete excluding 'P' or'S' trap (excluding cost of concrete for fixing(ii) 530 mm X 410 mm |
| 210 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware ofapproved make complete in position with necessary bolts, nuts etc.(a) With 'P' trap |
| 211 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (b) (a) E.W.C. (ii) Plastic (hallow type) white |
| 212 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).40 mm |
| 213 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes& fittings conforming to IS-15778: 2007(Q) Ball Valve40 mm |
| 214 | Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar). |
| 215 | Labour for dismantling G.I. pipe with fittings.15 mm |
| 216 | Labour for dismantling G.I. pipe with fittings. 20 mm |
| 217 | Labour for dismantling G.I. pipe with fittings.25 mm |
| 218 | Labour for dismantling G.I. pipe with fittings.32 mm |
| 219 | Labour for dismantling G.I. pipe with fittings.50 mm |
| 220 | Uprooting and removing plants from the surface of walls parapet etc and making good damages. (Repairing of damages to be paid separately). (a) Small plant of girth of exposed stem upto 75 mm. lift upto 6 mtr. |
| 221 | Labour for dismantling G.I. pipe with fittings.(ix) 100 mm |
| 222 | Taking out shutter of door and window, dismantling by parts (for repair or replacement of damaged parts) , reassembling and refitting and rehanging same with old fittings but with new screws as necessary. (Where different parts of same shutter are renewed under different item, payment under item 73 will be made once only). |
| 223 | Styles and rails of wooden shutters fitted and fixed complete. (Payment to be made on area of new work only). In Ground Floor: (ii) 35mm Thick shutter.b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.Ground floor |
| 224 | Styles and rails of wooden shutters fitted and fixed complete. (Payment to be made on area of new work only). In Ground Floor: (ii) 35mm Thick shutter.b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.First Floor |
| 225 | Styles and rails of wooden shutters fitted and fixed complete. (Payment to be made on area of new work only). In Ground Floor: (ii) 35mm Thick shutter.b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, HallakSecond Floor |
| 226 | Styles and rails of wooden shutters fitted and fixed complete. (Payment to be made on area of new work only). In Ground Floor: (ii) 35mm Thick shutter.b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, HallakThird Floor |
| 227 | Panel (made of single plank) of door and window shutters to design as directed:In Ground Floor(Payment to be made on area of exposed new work). (In case of non-supply ofsingle plank penal rate of reduction to a maximum of 30% will be made). (iii) 25mm thick panel of 30cm to 45cm width c) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak.Ground Floor |
| 228 | Panel (made of single plank) of door and window shutters to design as directed:(Payment to be made on area of exposed new work). (In case of non-supply ofsingle plank penal rate of reduction to a maximum of 30% will be made). (iii) 25mm thick panel of 30cm to 45cm width c) Sishu, Gamar, Champ,Badam,Bhola, Mogra, HallakFirst Floor |
| 229 | Panel (made of single plank) of door and window shutters to design as directed:(Payment to be made on area of exposed new work). (In case of non-supply ofsingle plank penal rate of reduction to a maximum of 30% will be made). (iii) 25mm thick panel of 30cm to 45cm width c) Sishu, Gamar, Champ,Badam,Bhola, Mogra, HallakSecond Floor |
| 230 | Panel (made of single plank) of door and window shutters to design as directed:(Payment to be made on area of exposed new work). (In case of non-supply ofsingle plank penal rate of reduction to a maximum of 30% will be made). (iii) 25mm thick panel of 30cm to 45cm width c) Sishu, Gamar, Champ,Badam,Bhola, Mogra, HallakThird Floor |
| 231 | Single Brick Flat Soling of picked jhama bricks including ramming anddressing bed to proper level and filling joints with local sand. |
| 232 | (A) Filling in foundation or plinth by silver sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. (payment to be made on measurement offinished quantity) |
| 233 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.Ground Floor |
| 234 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.First Floor |
| 235 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.Second Floor |
| 236 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.Third Floor |
| 237 | (a) M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.First Floor |
| 238 | (a) M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.Second Floor |
| 239 | (a) M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.Third Floor |
| 240 | (a) M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr.Fourth Floor |
| 241 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.Without integrated grills.(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]First Floor |
| 242 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.Without integrated grills.(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]Second Floor |
| 243 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.Without integrated grills.(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only]Third Floor |
| 244 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.Without integrated grills.(a) Fixed type steel windows as per IS sizes with horizontal glazingbars.First Floor |
| 245 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.Without integrated grills.(a) Fixed type steel windows as per IS sizes with horizontal glazingbars.Second Floor |
| 246 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.Without integrated grills.(a) Fixed type steel windows as per IS sizes with horizontal glazingbars.Third Floor |
| 247 | f) (ii) CP 2-way bib Cock - 15 mm, supplied, fitted and fixed. (Code No.5041 & Model - FLORENTINE of JAQUAR or similar brand). |
| 248 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. |
| 249 | Supply of Chlorinated Polyvinyl Chloride (CPVC) pipes& fittings conforming to IS-15778: 2007(Q) Ball Valve25 mm |
| 250 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(ii) Other than Coloured decorative including whiteGround Floor |
| 251 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(ii) Other than Coloured decorative including whiteFirst Floor |
| 252 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(ii) Other than Coloured decorative including whiteSecond Floor |
| 253 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) FloorWith Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @0.20kg/Sq.m.(a) Area of each tile upto 0.09 Sq.m(ii) Other than Coloured decorative including whiteThird Floor |
| 254 | Electrical Work (Schedule Item)Supply & fixing 415V 200A capacity MS (16SWG) Busbar Chamber having dimension of (500x150mm) to be fixed on iron frame on wall consisting of 4 nos cupper bars of size (4x20x5mm). |
| 255 | Supply & fixing of 1 nos of 240V 32A DP MCB (Legrand) in 2-way DP SS enclosure (Legrand) incl earthing attachment. |
| 256 | Supply & Fixing FP enclosure (Legrand) concealed in wall & mending good the damages to original finish incl. earthing attachment comprising with the following:a) 32 DP MCB Isolator (Legrand) - 1 nos b) 6-16 A SP MCB - 2 nos (Roof light & Stair light) |
| 257 | Supply & fixing SPN MCB DB (2+8) WAY (Make legrand/ Seimens/ABB) with S.S. Enclosure(Legrand cat no - 607711) concealed in wall after cutting wall & mending good the damages & earthing attachment comprising with the following: a) 40A DP MCB isolator --- 1 nob) 6 to 32A SP MCB ---- 8nos |
| 258 | Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through 19 mm alkathene pipe recessed in wall. a) 2 x 4 + 1 x 2.5 sq mm (SPNDB) |
| 259 | Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through 19 mm alkathene pipe recessed in wall. b) 2 x 2.5 + 1x1.5 sq mm (P/P plug/Com Plug/ Out door light) |
| 260 | Supply & drawing of 1.1 Kv grade single core stranded 'FR' Pvc insulated & unsheathed copper wire (brand appr by EIC) of the following sizes through 19 mm alkathene pipe recessed in wall. a) 3x1.5 sqmm (roof light) |
| 261 | Supply & fixing computer plug board modular type of 12 module GI box with cover plate recessed in wall comprising with the following (Legrand/Cabtree) ----- a) 6/16A socket & 16A switch --1 setb) 6A socket & 6A switch --2 sets |
| 262 | Supply & Fixing 240 V, 16 A, 3 pin Modular type Power plug socket (Cabtree) with 16A Modular type socket (Cabtree) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections |
| 263 | Distn. wiring in 3 x 1.5 sqmm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire Gloster/Finolex/ Havells) in 19 mm bore, 3 mm thick polythene pipe (for horizontal & vertical run in wall and celing portion through polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Legrand/Crabtree) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish ----- a) Ave run 6 Meter |
| 264 | Distn. wiring in 3 x 1.5 sqmm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Glostr/Finolex/Havells) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Cabtree) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl.mending good damages (on board) |
| 265 | Distn. wiring in 3 x 1.5 sqmm single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Glostr/Finolex/Havells) in 19 mm bore, 3 mm thick polythene pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Cabtree) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall incl.mending good damages average 4.5 Meter |
| 266 | Fixing only single /twin fluorescent light fitting complete with all accessories directly on wall / ceiling / HW round block and suitable size of MS fastener. |
| 267 | Supply & fixing socket type electronics Modular socket type fan regulator (Legrand/Crabtree) including connection. |
| 268 | Earthing the installation by 50mm dia GI pipe (ISI-M) 3.64 Meter long & 1x4 SWG GI (Hot dip) wire (4Meter long) with suitable nuts, bolts & washers etc. Driven into a depth of 3.65 Meter below the ground level. |
| 269 | S & F earth busbar of galvanized (Hot Dip) MS flat 25mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 270 | Electrical Work (Non-Schedule Item)Dismentalling all existing electrical installation mending good damages and the same to the respective authority as per direction of EIC |
| 271 | Supply and delivery of 4' single LED type tube light fitting complete with all acessaries directly on ceiling with HW round block & suitable size of MS fastener (make Havells/Crompton/Nordusk, cat no - -KN-TL-I-C-INT-T5-20W as approved by EIC) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender