Tender For Setting Up Of Barrack, Qtr., Boundary Wall, Ladies Toilet & Bathroom, Generator Set Etc. For Mondarmoni Coastal Police Station Under Purba Mdp Dist (Balance Work).
Tender Value
1.62 Crore
Estimated cost
Bid Submission
05 Sep 2026
20 days left
EMD
3.24 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas North → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Setting Up Of Barrack, Qtr., Boundary Wall, Ladies Toilet & Bathroom, Generator Set Etc. For Mondarmoni Coastal Police Station Under Purba Mdp Dist (Balance Work).
BOQ
| Sl. No. | Item Description |
| 1 | Civil works: Earth work in excavation of foundation trenches of drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils with in a lead of 75m. As directed. The item includes necessary trim-ming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. Depth of excavation not execeeding 1,500 mm |
| 2 | Earth work in excavation of foundation trenches of drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing spreading or stacking the spoils with in a lead of 75m. As directed. The item includes necessary trim-ming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water etc. as required complete. Depth of Excavation for additional depth beyond 1500 mm and upto 3000 mm but not requiring Shoring |
| 3 | Earth work in filling in foundation trenches or plinth with good earth, in layer not exceeding 150mm including watering and ramming etc. layer by layer complete a) With earth obtained from excavation of foundation. |
| 4 | (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) .(B) Do - by fine sand |
| 5 | Single brick flat soling of picked jhama bricks including ramming and dressing bed to proper level, and filling joints with powered or local sand. |
| 6 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety |
| 7 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. a) Pakur Variety |
| 8 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In round floor and foundation.[using concrete mixture] (b) M 25 Grade GROUND FLOOR |
| 9 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In round floor and foundation.[using concrete mixture] (b) M 25 Grade FIRST FLOOR |
| 10 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In round floor and foundation.[using concrete mixture] (b) M 25 GradeSecond FLOOR |
| 11 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete workGROUND FLOOR |
| 12 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete workFIRST FLOOR |
| 13 | Hire and labour charges for shuttering with centreing and necessary staging up to 4m using approved stout props thick hard wood planks of approved thickness with required bracing for concrete slabs, beams, columns, linteles curved or straight including fitting, fixing and striking out after complition of works upto roof og GF (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete workSecond FLOOR |
| 14 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction.For work in foundation,basement and and upto roof of/upto 4m For II. i) Tor steelJSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSLGROUND FLOOR |
| 15 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction.For work in foundation,basement and and upto roof of/upto 4m For II. i) Tor steelJSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSLFIRST FLOOR |
| 16 | Reinforcement for reinforced concrete work in all sorts structure including distribution bars, stirrups, binders etc. including of rods initial straightening and removal of loose rust (if necessary), cutting to requisite length , hooking and bending with 16 gauge black annealed wire at every inter section, complete as per drawing and direction.For work in foundation,basement and and upto roof of/upto 4m For II. i) Tor steelJSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSLSecond FLOOR |
| 17 | Brick work with 1st class bricks in cement mortar (1:6) GL TO PL(a) In foundation and plinth |
| 18 | Brick work with 1st class bricks in cement mortar (1:6) in Super Structure ,Ground Floor |
| 19 | Brick work with 1st class bricks in cement mortar (1:6) in Super Structure ,First Floor |
| 20 | Brick work with 1st class bricks in cement mortar (1:6) in Super Structure ,Second Floor |
| 21 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in GROUND FLOOR |
| 22 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in FIRST FLOOR |
| 23 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:4)in SECOND FLOOR |
| 24 | 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer's specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface). [Note: - Waterproofing as per item NO 60, polymer based paint as per item 59 (a) of Section (C). |
| 25 | Labour for Chipping of concrete surface before taking up Plastering work. |
| 26 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Sal MalayasianGROUND FLOOR |
| 27 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Sal MalayasianFirst FLOOR |
| 28 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). Sal : Sal MalayasianSECOND FLOOR |
| 29 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wideEach and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneerscomplete, including fitting, fixing shutters inposition but excluding the cost of hinges andother fittings in ground floor.(a) 32 mm thick shutters (single leaf)GROUND FLOOR |
| 30 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wideEach and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneerscomplete, including fitting, fixing shutters inposition but excluding the cost of hinges andother fittings in ground floor.(a) 32 mm thick shutters (single leaf)First FLOOR |
| 31 | Supplying solid flush type doors of commercial quality, the timber frame consisting of top and bottom rails and side styles of well seasoned timber 65mm wideEach and the entire frame fitted with 37.5mm wide battens places both ways in order to make the door of solid core and internal lipping with Garjan or similar wood veneerscomplete, including fitting, fixing shutters inposition but excluding the cost of hinges andother fittings in ground floor.(a) 32 mm thick shutters (single leaf)SECOND FLOOR |
| 32 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortar ,b) 10 mm thick plaster. Ceiling PlasterGROUND FLOOR |
| 33 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortar ,b) 10 mm thick plaster. Ceiling PlasterFIRST FLOOR |
| 34 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](ii) With 1:4 cement mortar ,b) 10 mm thick plaster. Ceiling PlasterSecond FLOOR |
| 35 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 6:1 cement mortar a) 20mm thick plaster OUTSIDEGROUND FLOOR |
| 36 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 6:1 cement mortar a) 20mm thick plaster OUTSIDEFIRST FLOOR |
| 37 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 6:1 cement mortar a) 20mm thick plaster OUTSIDEsecond FLOOR |
| 38 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 6:1 cement mortar b) 15mm thick plaster INSIDEGROUND FLOOR |
| 39 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 6:1 cement mortar b) 15mm thick plaster INSIDEFIRST FLOOR |
| 40 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 6:1 cement mortar b) 15mm thick plaster INSIDESecond FLOOR |
| 41 | Neat Cement Punning above 1.5mm thick in Wall dado,Window Sill Floor and Drain etc Note Cement 0.152 cum 100 Sqmts |
| 42 | White washing including cleaning and smoothening surface thoroughly.(b) Three coats (to be done on specific instruction). Inside |
| 43 | Cement washing including cleaning and smoothening surface thoroughly (cement to be used @15 kg./100 sq.m. of surface for one coat and @25 kg./100 sq.m of surface for two coats): External surface (Ground Floor)(b) Two coats (on new works only) |
| 44 | Cement washing including cleaning and smoothening surface thoroughly (cement to be used @15 kg./100 sq.m. of surface for one coat and @25 kg./100 sq.m of surface for two coats): External Surface (First Floor) |
| 45 | Cement washing including cleaning and smoothening surface thoroughly (cement to be used @15 kg./100 sq.m. of surface for one coat and @25 kg./100 sq.m of surface for two coats): External Surface (SecondFloor) |
| 46 | Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. Two coats.Ground Floor(external surface) |
| 47 | Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. Two coats.1st Floor (External Surface) |
| 48 | Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. Two coats.2nd Floor (External Surface) |
| 49 | Primming One coat on Timber or Plaster surface with Synthetic Oil bound Primer of approved Quality inclusing smooting surface by sand Papering etc |
| 50 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (a) On timber or plastered surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) |
| 51 | (b) Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 52 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : (b) iv) On Steel and other Metal Surface With super gloss (hi-gloss) -Two coat with any shade except white |
| 53 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 35 mm. thickGROUND FLOOR |
| 54 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 35 mm. thickFIRST FLOOR |
| 55 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. In ground floor.3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement (ii) 35 mm. thickSECOND FLOOR |
| 56 | 18 mm. to 22 mm. thick, kota stone slab setin 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing incement slurry with admixture of pigment matching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m]GROUND FLOOR |
| 57 | 18 mm. to 22 mm. thick, kota stone slab setin 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing incement slurry with admixture of pigmentmatching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m]FIRST FLOOR |
| 58 | 18 mm. to 22 mm. thick, kota stone slab setin 20 mm thick (avg) cement mortar (1:4) in floor, stair & lobby including pointing incement slurry with admixture of pigmentmatching the stone shade, including grinding& polishing as per direction of Engineer - in -charge to match with the existing work.[Slurry for bedding @ 4.4 kg/Sq.m andpointing @2.0 kg/Sq.m]SECOND FLOOR |
| 59 | Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) includingmaking suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shadeincluding grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]GROUND FLOOR |
| 60 | Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) includingmaking suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shadeincluding grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]FIRST FLOOR |
| 61 | Supplying, fitting and fixing 18 mm. to 22mm. thick kota stone slab in wall, dado in 15mm thick [avg] cement mortar (1:3) includingmaking suitable arrangement to hold thestone properly by brass / copper hooksincluding pointing in cement mortar (1:2) (1cement : 2 marble dust) with admixture ofpigments matching the stone shadeincluding grinding and polishing all completeas per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete.[Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]SECOND FLOOR |
| 62 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (a) Area of Each tile upto 0.09 Sq.m (i) Coloured decorative GROUND FLOOR |
| 63 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m (a) Area of Each tile upto 0.09 Sq.m (i) Coloured decorative First FLOOR |
| 64 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of Each tile upto 0.09 Sq.m (i) Coloured decorativeGROUND FLOOR |
| 65 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of Each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) Wall With Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(a) Area of Each tile upto 0.09 Sq.m (i) Coloured decorativeFirst FLOOR |
| 66 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria.. ii) 66mm x 70mm |
| 67 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria (25 MM THK)Ground floor |
| 68 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria (25 MM THK)First floor |
| 69 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc,including hoisting in position, straightening if required, fixing lugs in cement concrete (1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. In Ground floor.Flash butt welded windows and ventilators (No shop priming will be allowed to facilitate inspection of worksmanship).(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars with/without fixed type ventilators.[The extra rate admissible for the openable portion only]GROUND FLOOR |
| 70 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc,including hoisting in position, straightening if required, fixing lugs in cement concrete (1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. In Ground floor.Flash butt welded windows and ventilators (No shop priming will be allowed to facilitate inspection of the worksmanship).(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars with/without fixed type ventilators.[The extra rate admissible for the openable portion only]FIRST FLOOR |
| 71 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc,including hoisting in position, straightening if required, fixing lugs in cement concrete (1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. In Ground floor Flash. butt welded windows and ventilators (No shop priming will be allowed to facilitate inspection of the worksmanship).(a) Fixed type steel windows as per IS Sizes with horizontal glazing bars.GROUND FLOOR |
| 72 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc,including hoisting in position, straightening if required, fixing lugs in cement concrete (1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. In Ground floor Flash. butt welded windows and ventilators (No shop priming will be allowed to facilitate inspection of the worksmanship).(a) Fixed type steel windows as per IS Sizes with horizontal glazing bars.FIRST FLOOR |
| 73 | Supplying best Indian sheet glass panes set in putty and fitted and fixed with nails and putty complete. (In all floors for internal wall & upto 6 m height for external wall) ii) 4 mm thick |
| 74 | Extra for fixing glass panes in steel window |
| 75 | v)Two point nose aluminium handle including fitting and fixing. |
| 76 | vi)steel peg stay 300 mm long including fitting and fixing. |
| 77 | a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 16 Kg./sq. Meter.GROUND FLOOR |
| 78 | a) M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S,W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 16 Kg./sq. Meter.First FLOOR |
| 79 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugs set in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. IN GROUND FLOOR |
| 80 | Supplying,fitting and Fixing MS Clamps for Door and Window frame made of Flat bend Bar , end bifurcated with necessary screws etc by cement concrete (1:2:4) as per direction.(Cost of Concrete will be paid Seperately) 40mm x 6mm ,250 mm length |
| 81 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark 100mm X 50mm X 1.25mm |
| 82 | i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with 16mm dia rod with centre bolt and round fitting.250mm long |
| 83 | (ii) Anodised aluminium floor door stopper |
| 84 | Godrej Hydraulic door closer fitted and fixed complete.Medium Type |
| 85 | Anodised aluminium barrel / tower /socket bolt (full covered) of approved manufractured from extructed section conforming to I.S. 204/74 fitted with cadmium plated screws. 300 mm long X 10mm dia bolt. |
| 86 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixed complete:(a) With continuous plate base (Hexagonal / Round rod) (v) 125 mm grip x 12 mm dia rod. |
| 87 | (a) Applying 2 coats of bonding agent with synthetic multifunctional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer's specification. For Water Proofing at roof |
| 88 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes..(i)pakur variety (For Roof Concrete) |
| 89 | Supplying, fitting and fixing Black Stone slab used in Kitchen slab, alcove, wardrobe etc. laid and jointed with necessary adhesive Cement mortar (1:2) including grinding or polishing as per direction of Engineer-in -Charge in Ground Floor. (b) Slab Thickness above 25 mm and upto 37.5 mm |
| 90 | M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. In ground floor. |
| 91 | Supplying fitting and fixing 600 mm (+/- 30 mm) diaMeter R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as 'C' clips, R.B.T clips etc.) |
| 92 | Labour for fitting line of wire to posts, tightening by straining bolts and fixing the wire ( in taut condition) to the post with staples (including the cost of cutting and lapping joints in the wire, as necessary and including the cost of staples and straining bolts and also the labour for fixing the staples but excluding the cost of straining bolts) 24 Labour for fitting line of wire to posts, tightening by straining bolts and fixing the wire ( in taut condition) to the post with staples (including the cost of cutting and lapping joints in the wire, as necessary and including the cost of staples and straining bolts and also the labour for fixing the staples but excluding the cost of straining bolts) ( d) barbed wire |
| 93 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in- charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1956 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 1957, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. I) For structural members of specified sections weighing less than 22.5 kg/m. |
| 94 | Earth work in filling in compound, tank, low land, ditches etc. with good earth, in layers not exceeding 150 mm. including breaking clods and consolidating the same by ramming and dressing complete.(Payment will be made on profile measurement before and after the work)(iii) With carried earth arranged by the contractor within a radius exceeding 5 km. but not exceeding 10 km. including cost of carried earth. |
| 95 | Ornamental brick edging (75 mm wide) in compound roads, gardens etc.with 1st class or picked jhama bricks laid diagonally on end and with a corner slightly raised from the adjoining surface thus giving saw tooth appearance including cutting trench laying bricks and repacking the trench thoroughly on both sides of the edging complete as per direction. |
| 96 | SANITARY WORKSSupplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)40 mm(Main Riser) |
| 97 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)32mm(Roof ring) |
| 98 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)20 mm(Internal) |
| 99 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Exposed Work -- PVC Pipes (Dia)25 mm(Vertical) |
| 100 | Supplying, fitting and fixing PVC pipes of approved makeof (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) Supreem made(a) For Concealed work15 mm |
| 101 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).40mm |
| 102 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).32 mm |
| 103 | Supplying, fitting and fixing Peet's valve fullway gunmetal standard pattern best quality of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).25 mm |
| 104 | Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc. Hindware/Parryware/Cera, made (a) With 'P' trap (with vent) |
| 105 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P.hinges, rubber buffer and brass screws complete.(b) Anglo Indian (ii) Plastic (hallow type) white |
| 106 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc.White |
| 107 | Supplying, fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. (ii) 450 mm long |
| 108 | Supplying, fitting and fixing approved brand 32 mm dia. P.V.C. waste pipe, with coupling at one end fitted with necessary clamps. 1050 mm long |
| 109 | Supplying, fitting and fixing vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 32 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint. (ii) 550 mm X 400 mm size |
| 110 | Supplying, fitting and fixing pedestal of approved make for wash basin (white) |
| 111 | Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass 25 mm dia. and 600 mm long |
| 112 | Supplying, fitting and fixing best quality Indian make mirror 5.5 mm thick with silvering as per I.S.I. specifications supported on fibre glass frame of any colour, frame size 550 mm X 400 mm |
| 113 | Supplying ,fitting and fixing bib cock or stop cock.(a)(i)Chorium plated bib cock short body ( Equivalent to code.511 & Model - Tropical/Sumthing Special of ESSCO or similar brand). |
| 114 | Supplying ,fitting and fixing bib cock or stop cock.(c)(i) Chromium plated angular stop cock with wall flange (Equivalent to Code No. 5053 & Model- Florentine of Jaguar or similar brand) |
| 115 | Supplying, fitting and fixing pillar cock of approved make.a) (i) CP Pillar Cock - 15 mm. (Equivalent to Code No. 507 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 116 | Supplying, fitting and fixing shower of approved brand and make.(g) PTMT overhead shower (Prayag or equivalent) i) 75 mm round |
| 117 | Supplying ,fitting and fixing bib cock or stop cock.(e)PTMT (Polytetra Bib Cock / Stop Cock ( Prayag or equivalent)15 mm |
| 118 | Supplying, fitting and fixing pillar cock of approved make.b) PTMT Pillar Cock - 15 mm. (Prayag or equivalent). |
| 119 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Meter. Lengthc) 110 mm |
| 120 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(i) Door Tee (110 mm) |
| 121 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(ii)Bend 87.5 dig.(110 MM) |
| 122 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(iii) Door Bend 110 mm |
| 123 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) Fittings(iv) Vent Cowl 110 mm |
| 124 | Supply of UPVC pipes (B Type) and fittings conforming to IS-13592-1992(B) FittingsPipe Clip 110 mm |
| 125 | Labour for fitting and fixing U.P.V.C piupes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 Meter. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials)(A) Above ground (i) 110 mm |
| 126 | Labour for fitting and fixing U.P.V.C piupes for above ground work including cost of joining materials etc. fitting and fixing all necessary specials, cutting pipes,cutting holes in walls or R.C floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches upto 1.5 Meter. and refilling the same complete as per direction of the Engineer - in - Charge.(payment will be made on centre line measurment of the total pipe line including specials)(B) Under ground (i) 110 mm |
| 127 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.(i) 635 mm X 395 mm X 420 mm |
| 128 | Supplying, fitting and fixing C.I. round grating.(ii) 150 mm |
| 129 | Supplying, fitting and fixing C.I. square jalli.(ii) 150 mm |
| 130 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (b) 1000 litre capacity |
| 131 | Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayer (d) 2000 litre capacity |
| 132 | Labour for hoisting plastic water storage tank. (i) Upto 1500 litre capacity. Upto 1st storey from G.L. |
| 133 | Labour for hoisting plastic water storage tank. (ii) Above 1500 litre upto 5000 litre capacity. Upto 2nd storey from G.L. |
| 134 | Supplying fitting fixing PTMT smart shelf of approved make of size 300 mm |
| 135 | Suppling fitting fixing soap holder a)PTMT (Prayag or Equivelent) |
| 136 | Supplying,fitting and fixing stainless steel sink complete with waste fittings and two coats of painting of CI bracket,Sink Only 530mm x 430mm x 180 mm |
| 137 | Supplying, fitting and fixing 15 mm swan neck tap with left & right hand operating nob with aerator (Equivalent to Code No. 510, 510(A) and Model - TROPICAL / SUMTHING SPECIAL of ESSCO or similar brand). |
| 138 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. For SAIL/TATA/RINL (Pakur variety) |
| 139 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. For SAIL/TATA/RINL (Pakur variety)For 10 users |
| 140 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. For SAIL/TATA/RINL (Pakur variety)For 50 users |
| 141 | Construction of circular soak well 2.5 Meter deep in all types of sandy soils with dry brick work upto 1.6 Meter from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 Meter from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 Meter of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (6:1) and 1.00m inside dia. For SAIL/TATA/RINL |
| 142 | SINKING OF DEEP TUBE WELLLabour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system 9either by reserve circulation or by direct rotary method ) including hire charges and labour for rig machine , tools and plants , staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes , strainers, blind pipes etc. complete.(a) For depth upto 250 Meter for 100 mm dia. Tube well with top enlargement of 200 mm dia.(upto 50 Meter).(i) Frist 50 Meter |
| 143 | Labour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system 9either by reserve circulation or by direct rotary method ) including hire charges and labour for rig machine , tools and plants , staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes , strainers, blind pipes etc. complete.(a) For depth upto 250 Meter for 100 mm dia. Tube well with top enlargement of 200 mm dia.(upto 50 Meter).(ii) Next 50 Meter |
| 144 | Labour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system 9either by reserve circulation or by direct rotary method ) including hire charges and labour for rig machine , tools and plants , staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes , strainers, blind pipes etc. complete.(a) For depth upto 250 Meter for 100 mm dia. Tube well with top enlargement of 200 mm dia.(upto 50 Meter).(iii) Next 50 Meter |
| 145 | Labour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system 9either by reserve circulation or by direct rotary method ) including hire charges and labour for rig machine , tools and plants , staging, force pumping set and making arrangement for water required for boring etc. complete and lowering of pipes , strainers, blind pipes etc. complete.(a) For depth upto 250 Meter for 100 mm dia. Tube well with top enlargement of 200 mm dia.(upto 50 Meter).(iv)Rest 100 Meter |
| 146 | Supplying high density polythene strainer of approved make with adapter conforming to I.S specifications.(iv) 100 mm dia. |
| 147 | Supplying, fitting and fixing heavy type bell mouth reducing socket. (iv) 100 mm x 200 mm |
| 148 | Supplying, fitting and fixing G.I cap at top.(iii) 200 mm |
| 149 | Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yield in gallons per hour with 'V' notch including hire and labour charges for all tools and plants and scaffolding as required. |
| 150 | Collecting sample of water for bacteriological test & chemical test from any depth at any time during execution of work including hire & labour charge for tools & plants & sterilising the equipments, paying all charges & fees, testing etc. complete in all respect as per direction. |
| 151 | Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having size from 2 mm to 5 mm or the size approved by the Engineer-in-charge including cost of all materials labour and equipment complete.Note: Initial 6 m. of Annular space between the housing pipe and the bore should not be shrouded with Pea size gravel to avoid contamination with surface water. |
| 152 | Packing annular space between the outside of the housing pipe and the bore with puddled clay balls of approved size as per direction of the Engineer-in-charge with cost of all materials and labour complete. |
| 153 | Supply of PVC pipes & fittings schedule 80 ( medium duty) confoming to ASTMD-1785 and threded tomatch with G.I pipes as per IS : 1239 (Part-I)a) 100 mm dia PVC Pipes |
| 154 | Supply of PVC pipes & fittings ( medium duty) confoming to ASTMD-1785 and threded tomatch with G.I pipes as per IS : 1239b) 200 mm dia PVC Pipes |
| 155 | Geophysical investigation of the acquifer by electrologging system with all tools and plants as necessary including supply of necessary report. |
| 156 | Providing 200 mm centre guide.i) With clamp |
| 157 | (E) M.S Housing Clamp made of 120 mm wide M.S flat of 10 mm thick arm extended on both side 0.45 Meter. With two drilled hole 16 mm size both arm for insertion ofv total 4 nos. nut, bolt & washer all complete, fitted, fixed at floor level.iv) 200 mm dia. |
| 158 | SUPPLY & INSTALLATION OF PUMP SETSupply of Three phase 240V 5 Hp (3.7 Kw) stainless steel bore well submersible Pump Motor set suitable for 150mm bore well having overall head of (24 Meter to 40 Meter) & discharge of (370 LPM to 350LPM). The discharge outlet size will be 65mm (2.5\\" inch) (Make KSB/ Crompton/Kirloskar) |
| 159 | Supply & Fixing of control panel suitable for 3-Phase 5 HP Submersible Pump motor set comprising of DOL starter, Dual Ammeter & Voltmeter, indicator lamp to be fixed on wall incl making connection & necy. earthing attachment. (Make L&T/Crompton/KSB) |
| 160 | Supply & Laying 3 core 2.5 sqmm flat submersible cable (Finolex)incl. 3/4\\" PVC HD PVC pipe through U.G. trench with necy Jointing materials incl. S/Laying PVC HD PVC pipe (Oriplast) |
| 161 | Supply & installation of G.I. pipe (Make TATA-M) pipe having heavy duty G.I. socket/elbow (TATA) incl cutting & threading as required a) 65mm dia (For Vertical column pipe & upto Header) (A)-(II) G.I. pipe & fittings item no -1(g) (ii) |
| 162 | Supply & installation of G.I. pipe (Make TATA-M) pipe having heavy duty G.I. socket/elbow (TATA) incl cutting & threading as required b) 50mm dia (Header to delivery pipe line upto Barrack building) |
| 163 | Supplying, fitting and fixing Peet's valve fullway gunmetal standardpattern best quality of approved brand bearing I.S.I. marking with fittings(tested to 21 kg per sq. cm.). (iii) 65 mm dia(A)-(II) G.I. pipe & fittings item no -4 |
| 164 | Supply & fixing 50 mm dia G.I.Peets Valve(ISI)(Tested 21 kg per cm) (A)-(II) G.I. pipe & fittings item no -4 |
| 165 | Supply of 100 mm x 65 mm dia PVC Reducing Tee (For header) |
| 166 | Supply of 100mm dia PVC nipple short piece 150mm long |
| 167 | Supply of 100mm dia PVC end plug |
| 168 | Supply of 65 mm x 50 mm dia PVC Reducing socket (For delivery Line from header) |
| 169 | Supply of 50 mm dia PVC Union (A)-(II) G.I. pipe & fittings item no -(I) |
| 170 | Supply of 50 mm dia PVC Flange (A)-(II) G.I. pipe & fittings item no -(G) |
| 171 | Making holes on wall & mending good the damages to original finish |
| 172 | Construction of 200mm x 200mm x 900mm high brick pillars with cement plastering for supporting the G.I. pipe from tube well to header |
| 173 | Supply & fixing holding clamp fabricated by 50mm x 6mm with necy. Nuts, bolts & washers for holding the the column pipe. |
| 174 | Labour charge for Testing & Lowering the submersible Pump motor set with submersible cable along with the column pipes into the tube well after socketing the column pipes step by step including arrangement of tripod, chain pully & tools & Tackles & providing suitable manpower to satisfactory operation. |
| 175 | Drive WayEarthwork in excavation from borrow pits (land owned/arranged by the Department) and depositing in layers of 250 mm. including breaking clods in embankment works and to fill up back of abutments, depressions and ruts with an initial lead up to 50 m and initial lift up to 1.5 m making bunds at top as directed dressing complete. (Payment to the contractor is to be made on the basis of borrow pit measurement) (i) In ordinary soil |
| 176 | Box cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary. Depth up to 450mm. |
| 177 | Granular Sub-base with Graded Material, (Table:- 400-1):- Mix In Place Method: Construction of granular sub-base by providing graded material, mixing in Wet Mix Plant at OMC, carriage of mixed material to work site, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber, compacting with vibratory power roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants and cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MORT&H (5th Revision). (ii) Grading - II, G.S.B. |
| 178 | Water Bound Macadam Base Course :- Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate, watering including lighting, guarding, barricading and making necessary earthen bundh of one Meter width on Each side and preparing the bed by necessary cutting or filling, including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density, as per Clause 404 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (iii) Grading-II aggregate (53 mm to 22.4 mm) Using Stone Screening Type B (11.2 mm) WBM |
| 179 | Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code,laid in pattern as directed in pavement, footpath, driveway(paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately]. Note: Sub-grade CBR should not be less than 5. (c) 60 mm thick interlocking designer concrete paver block M-35 grade for light-traffic zone, commercial & office complex, tourist resort as per IS: 15658-2006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular /granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering , including cost of sand for sand bed but excluding cost of base, sub-base course & subgradepreparation). (ii) Coloured Decorative |
| 180 | [B] HARD SHOULDERINGBox cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary. Depth up to 150 mm. |
| 181 | Construction of Sub Base using Local Materials, spreading in uniform layers with Motor grader on prepared surface, including screening the metal as necessary, mixing by mix in place method with Rotavator at OMC, and compacting with vibratory roller to achieve the desired density, lighting, guarding and barricading including cost and carriage of all materials and making necessary earthen bundh of one Meter wide on Each side to protect the edges complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision).For Construction of Sub Base by compacting 1st class brick aggregates (40 mm down) and sand (in proportion of 60:40). |
| 182 | Supplying Sal-bullah piles at work site, including dressing and making one end pointed. (iii) 150mm diameter |
| 183 | Coal tarring on wooden surfaces including cost of materials. (a) Double coat. |
| 184 | Labour for driving Sal-bullah / Eucalyptus bullah piles by monkey in sorts of soil including hoisting and placing piles in position, protecting the pile head with iron ring and cutting and shaping heads before and after driving and including hire and labour for necessary driving appliances and all tackles. (iii) 150mm diameter |
| 185 | Extra over the corresponding item of earth work for removing semi liquid mud or slushy earth by iron pans, buckets etc. |
| 186 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety ](a) 1:3:6 proportion |
| 187 | Supplying Sal-bullah piles at work site, including dressing and making one end pointed.(i) 100mm diameter |
| 188 | Supplying, fitting, fixing bolts with nuts, washer: (i) 10 to 16 mm dia: (c) Length above 150mm. |
| 189 | Walling or roofing fitted and fixed complete with cut drum sheets including the cost of drums, cost of cutting drums and flattening the sheets and cost of necessary nails and screws.(Cost of empty bitumen drums issued by the Deptt. will be recovered at Rs. 100.00 for each drum) |
| 190 | Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials. |
| 191 | M.S. structural works with hollow sections (square or rectangular shape) conforming to IS: 806-1968 & IS:1161-1998) connected to one another with bracket, gusset, cleat as per design, drawing & direction of Engineer-in-Charge complete including cutting to requisite shape & size, fabrication including metal arc welding conforming to IS: 816-1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of all M.S. Hollow section, all consumables such as electrodes, gas and hire charges of all tools and plants and labour reqired for execution and all incidental chages (such as lectricity, labour insurance) etc. complete. a) Span up to 12 Mtr 1) 40mm dia 2.9mm thick |
| 192 | ELECTRICAL SCHEDULE ITEMS Supplying and fixing 415V, 125A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. [Make : L&T/HAVELLS] [For Barrack Building] |
| 193 | Supplying and fixing 415V, 125A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc. [For Barrack Building] |
| 194 | Supplying & fixing 415V, 200A, 4 Nos. Aluminium Bars 85mm long, 500x150mm sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – ( As per Drawing no. 470 of PWD Specification Book – May 1991). [For Barrack Building] |
| 195 | Supplying and fixing 415V, 63 A TPN SFU with sheetsteel enclosure on angle iron frame on wallwith nuts bolts etc incl. S & F 3 nos. DIN type HRCfuse as per rating. (Make : L&T/Havells/HPL or equivalent as approved by EIC.) [For Canteen Building] |
| 196 | Supplying and fixing 415V, 32 A TPN SFU with sheetsteel enclosure on angle iron frame on wallwith nuts bolts etc incl. S & F 3 nos. DIN type HRCfuse as per rating. (Make : L&T/Havells/HPL or equivalent as approved by EIC.)[For Pump] |
| 197 | Supplying and fixing 240V 32A DP Sheet steel Main Switches with fuse on L&N on flat iron frame on wall.[Make Havells/HPL] [For OC Quarter & Ladies Changing room] |
| 198 | Laying of one No. cable 50 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Metre. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed. [From nearest power supply to Barrack & DG Cable and Barrack to Canteen Building] |
| 199 | Laying of one No. cable 2 Core 6 Sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Metre. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed. [From Barrack Building Ladies Changing Room] |
| 200 | Laying of cable upto 2 core 6 sqmm on wall/surface incl. S & FMS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages andpainting (For Street Light) |
| 201 | Supplying and fixing compression type gland and socket complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of 4 Core 50 Sqmm XLPE/PVC armoured cable.[For Main Incomer Cable] |
| 202 | Supplying and fixing compression type gland complete with brassgland, brass ring & rubber ring for dust & moisture-proof entry ofXLPE/PVC armoured cables as below : 2 Core 6 Sq mm cable including with Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : 2 Core 6 Sq mm Cable.[From Barrack Busbar to Ladies Changing Room Main Switch and 14 Nos. of Street light Loop Box] |
| 203 | Supplying and fixing double door 4 Way Horizontal TPN MCBDistribution board Enclosure (607715) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment including following items. (Make : All Legrand/ L&T/Havells or equivalent as approved by EIC.)a) 415V, 63 A FP Isolator...................... 1 Nos.b) 240 V, 40 A SP MCB (10kA & 'C' curve)............... 3 Nos.c) 240V, 16/32 A SP MCB (10kA & 'C' curve)............. 9 Nos.[For Barrack Building & Canteen Building] |
| 204 | Supplying and fixing (2+12 Way) double-door SPN MCB Distribution Board Enclosure (607712) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment including (Make : All Legrand/ L&T/Havells or equivalent as approved by EIC.)a) 240V, 40A DP Isolator............... 1 Nos.b) 240V, 6 - 32A SP MCB (10kA & 'C' Curve).............. 12 Nos.[ For Barrack Building - 4 Set & For Ladies Changing Room - 1 Set & for canteen building 1 Set ] |
| 205 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:a) 23 cm (9\\")[ For Barrack Building - 8 Set, For Canteen Building - 3 Set, For Ladies Changing Room - 2 Nos. OC ROOM -2 ] |
| 206 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For Al , 23 cm Exhaust fan (9\\"). |
| 207 | Supplying and fixing MCB SS 4 pole enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment including (Make : All Legrand/ L&T/Havells or equivalent as approved by EIC.)a) 40 A DP MCB Isolator............. 1 Nos.b) 6-32A range SP MCB('C' Curve & 10kA Charecteristics)... 2 Nos.[Street Light Controlling DB for Barrack, canteen & ladies Changing Room] |
| 208 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand Polycab/Finolex/Havells/KEI or equivalent as approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand Legrand/Crabtree or equivalent as approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish (Average Run 8 Metre).Tube - 120, Fan - 50, Exhaust fan - 15, Recessed Light fittings - 30Total point : 205 |
| 209 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point incl. S&F 240 V 6A 3 pin Modular type plug socket & Modular type switch (Brand approved by EIC) incl. S&F earth continuity wire, fixed on 4 Module GI switch board with 3/4 Module top cover plate flushed in wall .On Board |
| 210 | Supply & Fixing 240 V, 2nos. 6A, 3 pin Modular type plug socket (Brand approved by EIC) with 2nos.6A Modular type switch, without plug top on 6 Module GI Modular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 211 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Make Legrand / Crabtree or equivalent as approved by EIC.) |
| 212 | Supply & Fixing 240 V, 25A Modular type socket, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C-Curve) and 6 Module GIModular type switch board with 6 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (For OC Quarter) |
| 213 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board withtop cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 214 | Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWGincl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles a) 19 mm dia 3 mm thick polythene pipe without earth continuity wire. |
| 215 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required including (For PP/ Seperate Socket) (i) 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC. |
| 216 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and makingnecy. connection as required including (For TPNDB to SPN DB)(y) 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC. |
| 217 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required including (Main Switch to TPN Connection)(d1) 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC. |
| 218 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., includingsupplying sockets, tapes.i) 2.5 Sq mm. |
| 219 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., includingsupplying sockets, tapes.i) 4 Sq mm. |
| 220 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., includingsupplying sockets, tapes.i) 6 Sq mm. |
| 221 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., includingsupplying sockets, tapes.i) 10 Sq mm. |
| 222 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 223 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 224 | Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling/HW round block and suitable size of MS fastener. |
| 225 | Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate andconnecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length. |
| 226 | Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. |
| 227 | Fixing only outdoor / street light type fluorescent light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required andmending good damages to wall incl. painting etc.(For Compound Light) |
| 228 | Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below, Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1) after dismantling the damaged looping cable box etc. where necy. incl. painting (For Compound Light)(a) 200 x 150 x 100mm . |
| 229 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required (50 mm dia). For Cable Protection |
| 230 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled withbitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: By ISI-Medium GI pipe. |
| 231 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required. |
| 232 | Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc. |
| 233 | ELECTRICAL NON-SCHEDULE ITEMS Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. [Brand approved by the EIC](IS 7098 Part - 1/2011 with Up To Date Amendments.)2 core 6 sqmm |
| 234 | Supplying and delivery of following size Armoured cables XLPE/PVC insulated are designed for 1.1 kV Stranded Aluminium conductor, high tensile galvanized steel wire/strip armour for mechanical protection, and PVC/FR PVC outer sheathing power cable of following size. [Brand approved by the EIC](IS 7098 Part - 1/2011 with Up To Date Amendments.)4 core 50 sqmm |
| 235 | Supplying and delivery of LED Industrial Batten light made of CRCA Sheet Body (Thickness ≥ 0.50 mm) and construction as per relevant IS, along with LED lamp (Opal finish polycarbonate housing with Aluminium end-cap) voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 0o to 40o C, internal surge protection of 2.5 KV(internal) with Short & Open circuit protection , THD < 10% , P. F.≥0.9, IP20, CRI >80, and minimum 40000 Burning Hours (Life projection shall be calculated as per TM-21 methodology), CCT 5700°K /6500°K, and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing, with Minimum 5 year OEM warranty. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. (System lumen efficacy ≥115 lm/Watt).Single fittings along with S/F of 1 no. 18-20 W LED lamp as per specification[Brand approved by the EIC] |
| 236 | Supplying, installation, Testing & Commissioning of 12 - 15 Watt LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD with powder-coated pressure Die-cast Aluminium with high-transmission opal PMMA/ polycarbonate/ prismatic diffuser having uniform light distribution and construction as per IS : 10322. The driver rated output wattage should be 10% to 15% higher than lamp rating and efficiency Driver >80%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range 00 to 400 C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , PF ≥0.9, IP20, CRI >80, life time (LED, Driver & electrical circuitary), of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect and LED Chips of SMD Low to mid-power, as per requirement (LM-80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement.[ Brand Approved by EIC]System lumen efficacy ≥ 110 lm/Watt, |
| 237 | Supplying, installation, Testing & Commissioning of 90W Street light LED fixture powder coated pressure die cast aluminum body finish with corrosion resistance fasteners (SS hardware) & silicon gasket for proper sealing with driver as per the requirement with Driver efficiency >80%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range 0o to 50o C and working RH 10% - 90%, internal surge protection of 5 KV internal and external SPD min. 10 KV, L,N,E as per IEC 61000-4-5. The driver rated output wattage should be 10% to 15% higher than lamp rating and at least 2 driver for 200W & above and Driver efficiency >85%, THD < 10% as per IEC 61000-3-2 , P. F.≥0.9, IP- 66, IK-08 specified below, CRI >70, undervoltage and over voltage protection, high efficiency lens with type II/III distribution as required with UV stabilized optical lens, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours (Life projection shall be calculated as per TM-21 methodology) and 70% of initial Lumen maintained till life ends. CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect and LED Chips of SMD mid to high-power (2.5 to 4 watt for 200 watt and above, as per required (LM- 80 tested) and necessary inter-connections with 1.5 sq mm FR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM comprehensive on-site warranty against manufacturing defects including driver and LED module. All test report except L80 should be from 3rd party NABL accredited Lab as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. [Brand approved by the EIC] |
| 238 | Supply & delivery of 230 V, 50 Hz, single phase, 52 watts, 48\\" (1200 mm)Sweep, speed 320 rpm (minimum), A.C. Ceiling Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod (14 SWG & higher thickness), 2 nos. canopies, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 210 cu.m/min (minimum), without Regulator including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required.[Brand Approved by EIC] |
| 239 | Supply & delivery of 230 V, 50 Hz, single phase, 40 watts , 9\\" (230 mm) Sweep, speed 1350 rpm (minimum), A.C. Exhaust Fan and class of insulation: B, 3 nos. metal (Aluminium alloy) blades, copper winding, steel/Al body. Power Factor not less than 0.9 and minimum air delivery 650 cmh (minimum) including capacitor with safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for compliant to IS 374:2019 and external connections with 1.5 sq.mm FR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 240 | Supply, delivery and testing of 3-Phase, 415 Volts 5 HP with upto 5 stages, head metre 55-13, discharge LPM 120-510.[Brand Approved by the EIC] |
| 241 | Supply of ISI Marked Direct On-Line Starters for 5 HP submershible pump confirming to IS : 13947-4 with suitable over load relay range and contactor size, 415 V , 3 -Phase with two earthing terminals [Brand Approved by the EIC] |
| 242 | Supplying and laying of submersible flat cable ISI marked 3 core 2.5 sqmm copper wire of suitable size with proper clamping of approved make. [Brand Approved by the EIC] |
| 243 | Supply, Installation, Testing and Commissioning including delivery to the site of 25 KVA, 3-Phase, 415V, 50Hz Diesel Generator Set (CPCB-IV compliant) of approved make such as Mahindra Powerol Model No M3205G3, / Kirloskar / Jackson (or equivalent). The DG set shall be compact, sleek in design and suitable for manual/automatic operation, enclosed in a soundproof and weatherproof acoustic enclosure of modular construction, allowing easy assembly and dismantling. The enclosure shall be fabricated from properly pre-treated sheet metal components with polyester-based powder coating (inside and outside) for long life and durability under extreme environmental conditions, including UV resistance. All nuts, bolts and hardware shall be of stainless steel for extended service life.The DG set shall be designed for low vibration and low fuel consumption, equipped with Class A1 governing system ensuring better speed accuracy, reduced transient speed drop and faster recovery time. It shall have low operation cost and low maintenance cost, with easy availability of service and spares.The DG set shall be equipped with a standard control panel (AMF/manual as required) mounted within the enclosure, along with necessary instrumentation and protections. The safety features shall include protection against high water temperature, low lube oil pressure, and provision of emergency stop push button located outside the enclosure. The scope includes supply, transportation, loading-unloading, installation, foundation (if required), cabling, earthing, exhaust piping with insulation, testing, commissioning, trial run, and handing over of the DG set in complete working condition, as per specification and direction of the Engineer-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 20 daysSep 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender