Tender For Repair/ Replacement & Cleaning Of Sewage Line, Septic Tank, Soakage Well Etc Under Aor Of Age B/R Dett-B Of Ge 862 Ews
Tender Overview
Project Description
Tender for Repair/ Replacement & Cleaning Of Sewage Line, Septic Tank, Soakage Well Etc Under Aor Of Age B/R Dett-B Of Ge 862 Ews
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Aug-2026 | Corrigendum1 | BOQ | 31-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | M&L for cleaning and de-sludging of existing septic tank completely of solid/liquid sludge of any depth by pumping or manually from inside the septic tank and removal of sludge to a distance exc 1.00 KM outside defence land by mechanically (trolly mounted) and depositing/buried in and including excavated pits (required size and depth) of any type of soil. Top layers of excavation pit covered by layers of 150mm depth earth spreading with bleaching powder @ 200 gm per Sqm for disinfections purpose including taking down cover slab and refixing the same in cement mortar (1:4) complete all as specified and directed. |
| 2 | M&L for systematically cleaning and de-silting/de-sludging of blocked sewage pipe line 150mm dia and any depth including taking out sludge/silt and other foreign materials from sewage line by rodding with using steel rod or split bamboo sticks thoroughly from both sides between adjacent manholes still clear flow of sewage line is observed, passing knots, kamti and disc of required size or pumping out liquid waste /sewage, plugging and diverting the flow to the drain if necessary and stacking the removed silt/sludge in deposits outside defence land as directed including taking precautionary measures such as safety belts, dry cell torch for lighting inside the manholes and drain etc, sprinkling bleaching powder on the silt/sludge to removed to avoid bad smell and disposal of silt complete all as specified and as directed. Note : Rate deem to be inclusive of excavation of earth pits and bleaching powder if required for disposal of silt. |
| 3 | All as per item No 2.00 here-in-before but 100 mm dia. |
| 4 | All as per item No 2.00 here-in-before but 200 mm dia. |
| 5 | M&L for cleaning of blockage of WCs including P or S traps, floor/gully traps of any size and depth upto and including 1st manhole manually with necessary T&P as per the site requirement complete all as specified and directed. Note:- Cost of cleaning of 1st manhole shall be deemed to be inclusive in the unit rate of this item quoted by the tenderer) |
| 6 | M&L for cleaning of blocked manhole up to 1.50m deep and taking out sludge, soil, sludge water etc manually/mechanically and removing the same to a distanace exceeding 1.00km outside Military/ Defence land, deposited/bruied in and including excvated pits (required site and depth) all as directed including digging of pits in any type of soil and covering pits with earth after filling of sludge and including providing and spearding of bleaching powder @ 200gm per sqm for disnifecation purpose, including taking down of slab cover and refixing the same in cement mortar (1:4) complete all as specified and directed. |
| 7 | M&L for LLDPE septic tank designed for 10 users to carry sewage and sludge water, excavation of any type of soil, PCC (1:4:8) type D-2 in foundation of 100mm thick as per septic tank size, vent shaft, connection etc including refilling of soil at sides of tank, well ramming in layers and removing execavated surplus soil to a distance not exceeding 50m complete after demolition or dismantling old unserviceable septic tank, complete all as specified and directed. |
| 8 | M&L for LLDPE septic tank designed for 20 users to carry sewage and sludge water, excavation of any type of soil, PCC (1:4:8) type D-2 in foundation of 100mm thick as per septic tank size, vent shaft, connection etc including refilling of soil at sides of tank, well ramming in layers and removing execavated surplus soil to a distance not exceeding 50m complete after demolition or dismantling old unserviceable septic tank, complete all as specified and directed. |
| 9 | M&L for construction of soakage well 1.8 Mtr dia and 3 M deep including excavation of earth work in any type of soil, PCC (1:3:6) type C-2 in foundation, walls of honey combed masonry with top ring of M-25 concrete including intercerpting chamber and screen chamber made of Brick masonry in cement mortar (1:4), RCC cover slab in M-25, interconnecting pipes of RCC complete filled with brick bats complete after demolition of old unserviceable soakage well all as specified and shown all as per drawing No CE/TD 1202/2008, sheet No.1/2 & 2/2. |
| 10 | Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth for foundation etc and not exceeding 10sqm on plan and getting out in soft/loose soil, complete all as specified and directed. |
| 11 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm (soil), complete all as specified and directed. |
| 12 | Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed. |
| 13 | S&F 150 mm bore grade 'A' salt glazed stone ware pipes laid in trenches and jointed in cement mortar (1:1) including testing after demolition and breaking up existing sewage pipe of any type complete all as specified and directed. |
| 14 | M&L for PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 150 mm bore SGSW pipe, complete all as specified and directed. |
| 15 | S&F PVC (SWR) 110mm bore pipes, single socketed, in any length with rubber ring joints laid in floors or trenches after dismantling of cast iron or PVC or reinforced concrete drain pipe, jointed in cement mortar and taking out of trenches if required complete all as specified and directed. |
| 16 | S&F 110mm bore for PVC (SWR) bend any radius, complete all as specified and directed. |
| 17 | S&F PVC (SWR) 75mm bore pipes, single socketed, in any length with rubber ring joints laid in floors or trenches after dismantling of cast iron or PVC or reinforced concrete drain pipe, jointed in cement mortar and taking out of trenches if required complete all as specified and directed. |
| 18 | S&F 75mm bore PVC(SWR) bend any radius, complete all as specified and directed. |
| 19 | Demolition of Brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles, complete all as specified and directed. |
| 20 | M&L for PCC (1:4:8) type D2 (using 40mm graded stone aggregate( as in foundation, filling and mass concrete in manholes, complete all as specified and directed. |
| 21 | M&L for brick work with sub class 'B' bricks, old size, straight or curved on plan exceeding 6 m mean radius, built in cement mortar 1:6, complete all as specified and directed. |
| 22 | All as per Item No 21.00 here-in-before but except bricks. |
| 23 | M&L for PCC (1:3:6) type C1 (using 20mm graded stone aggregate) as in coping, benching and other similar work (location) with weathering slightly rounded edges and throating etc as required with and incl all necessary form work, complete all as specified and directed. |
| 24 | M&L for Rendering 15 mm thick on fair faces of brick wall or concrete surface in cement mortar (1:4), mixed with and including water proofing compound as per manufracturer's instructions, finished even and smooth without using extra cement, complete all as specified and directed. Note:- WPC shall be measured and paid separately as \\"Supply Only\\". |
| 25 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 26 | M&L for precast RCC (1:2:4) type B1 (using 20mm grades stone aggregate) as in landings, cover slab, chajjas etc.and similar articles with plain faces, set in cement mortar (1:6) complete all as specified and directed |
| 27 | M&L for mild steel TMT bars 8 to 10mm dia (as per requirement) cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed. |
| 28 | Demolition of cement concrete of any description and in any position not other wise specifically provided for complete all as directed. |
| 29 | M&L for cutting into existing manholes of 150mm (internal dia) for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20mm grades stone aggregate) smooth finished, and reforming benching as required complete all as specified and directed. |
| 30 | M&L for water proofing treatment to sunken portion (floor and wall) of WCs, bathroom etc as per following :-(a) Complete removal of existing filling and treatment over RCC slab and making a slope of 1:8 in and including PCC (1:2:4) with minimum thickness 30mm using 12.5mm graded stone aggregate and providing all wall and floor joints with coved fillet in PCC (1:2:4), having a radius of 70mm.(b) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with Acrylic based polymer modified cementitous composite compound @ 0.126 Kg/Sqm. This layer will be allowed to air cure for 4 hours.(c) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with Acrylic based polymer modified cementitous composite compound @ 0.126 Kg/Sqm. This layer will be allowed to air cure for 4 hours.(d) Sealing of joint of Trap/WC/Soil pipes with sealing compound of MC Bouchemie/Roofex/Forre/Choksy/Dr Beck & Coty/FOSROC |
| 31 | M&L for cement concrete (1:5:10) type E2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, complete all as specified and directed. |
| 32 | M&L for cement concrete (1:2:4) type B2 (using 40 mm graded stone aggregate) as in surface channel and drain, complete all as specified and directed. |
| 33 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete,using extra cement, including form, moulds, mitred/stopped ends etc, complete all as specified and directed. |
| 34 | M&L for 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement including fixing in cement concrete (1:2:4) type B-1 complete as in repair all as specified and directed. |
| 35 | S&F vitreous China wash down water closet (Pedestal pattern) white, excluding fixing bolts, flushing cistern and flush pipe including plastic water closet seat, black, closet pattern with recessed bottom and cover and mild steel chromium plated or aluminised hinging device and including set of CP jet with connecting PVC pipe of superior quality complete as in repair all as specified and directed. |
| 36 | S&F vitreous China squatting pan Orrisa pattern 580x440mm size pan white with front or back inlet with integral 'foot rests including provn of lime concrete bedding and including connections to 'flushing cistern/ pipe, complete all as specified and directed. |
| 37 | S&F vitreous China urinals, flat back of size 465mm X 355mm X 265mm, white with grating and union for discharge pipe including connecting to waste pipe, including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60cm long brass screws, pointing around urinal back in cement complete as in repair all as specified and directed. |
| 38 | S&F 10 ltr capacity PVC valveless, syphonic action type, flushing cistern low level, white, with inlet, ball valve, float and handle including MS brackets duly painted complete as in repair all as specified and directed. |
| 39 | S&F vitreous China wash basin, white, flat back, size 550x 400mm including 15mm bore pillar tap cast copper alloy, PVC connection 15mm length 450mm, low density PVC waste pipe complete as in repair all as specified and directed. |
| 40 | S&F 15 mm bib tap cast copper alloy with crutch or butterfly handle, chromium plated fancy type screwed for iron pipe, complete as in repair all as specifed and directed. |
| 41 | S&F in repair 15 mm CP angle valve, cast copper alloy, fancy type,chromium plated suitable for iron pipe and one end and PVC connector on other, ISI marked all as specifed and directed. |
| 42 | S&F in repair CP soap dish holder fixed with including chromium plated brass screws, complete all as specified and directed. |
| 43 | S&F in repair for chromium plated tubular towel rail 20 mm dia \\"D\\" type 60 cm long between flange,fixed with screw wooden / plastic cleats complete all as specifed and directed. |
| 44 | S&F in repair SS Towel Ring 300mm dia, complete all as specified and directed. |
| 45 | S&F in repair gun metal globe or Brass gate valve with iron wheel screwed both ends for iron pipe of 15 mm dia, complete all as specified and directed. |
| 46 | S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and directed. |
| 47 | S&F in repair PVC connection 15 mm x 450 mm including PTMT nuts at both ends screwed for iron pipe of 15 mm bore complete as in repair, complete all as specified and directed. |
| 48 | S&F in repair 15mm CP brass health faucet (hand shower), inlet length 100mm fixed to angle valve with and including decorative choice flexible pipe, wall hanger etc, complete all as specified and directed. |
| 49 | S&F in repair 600x450 mm bavelled edge mirrior of selected quality glass mounted on 6mm AC building board of commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 50 | S&F in repair premium multipurpose wall mounted storage cabinet with mirror of hard thermosetting plastic of size 600x450mm, fitted with superior quality distortion free 4mm thick mirror, complete all as specified and directed. |
| 51 | S&F in repair of CP brass WHB mixers for hot and cold water mixing of 15mm dia screwed down for iron pipe complete all as specified and directed. |
| 52 | S&F in repair 15 mm bore brass CP sink mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specifed and directed. |
| 53 | S&F in repair wall mixer with hand shower arrangement with connection legs wall flanges and wall bracket for hand shower, complete all as specified and directed. |
| 54 | Taking up or down GI tubing 20 mm bore and connections including cleaning for refixing or removal complete all as specified and directed. |
| 55 | M&L for 20 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specified and directed. |
| 56 | Fixing only 20mm bore tubes, any grade, to walls and ceilings or laying in floor with all new fittings complete all as specified and directed. Note:- Using old serviceable pipes obtained from taking down. |
| 57 | Taking up or down GI tubing 15 mm bore and connections including cleaning for refixing or removal complete all as specified and directed. |
| 58 | M&L for 15 mm bore galvanized iron GI tubing medium grade with all fittings such as bends, socket, Tee, Elbow, union, Nipple, short pieces and fixed to walls, ceilings or laid in floors complete all as specified and directed. |
| 59 | Fixing only 15mm bore tubes, any grade, to walls and ceilings or laying in floor with all new fittings complete all as specified and directed.Note:- Using old serviceable pipes obtained from taking down. |
| 60 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing ), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 61 | M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set & jointed in neat cement slurry and pointed in coloured cement to match colour of tiles, laid over and including 15 mm thick screed bed or bedding layer in cement mortar (1:4) complete all as specified and directed. |
| 62 | M&L for glazed ceramic tiles on vertical surfaces such as dado/skirting of size 450x300x7 mm thick, set & jointed in neat cement slurry and pointed in coloured cement to match colour of tiles, laid over and including 10 mm thick rendering in cement mortar (1:4) complete all as specified and directed. |
| 63 | Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed. |
| 64 | S&F Solid PVC door frame of size 50mm X 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tubes, as per specifications and drawing, complete all as specified and directed. |
| 65 | S&F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. |
| 66 | S&F 100 mm size stainless steel butt hinges medium weight cold rolled fixed to frame, complete all as specified and directed. |
| 67 | S&F 150 mm long,aluminium,anodised, barrel tower bolts of extruded section, complete all as specified and directed. |
| 68 | S&F 150mm long aluminium handles, cast type, anodised, complete all as specified and directed. |
| 69 | Supply only integral water proofing compound conforming to IS, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
TodayBid Submission Deadline
Online submission via eProcurement portal.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender