Banking and Finance Government Departments Closing in 0 days TDR #56933001

Bids Are invited for Air Conditioning Work At Golf Green Residential Complex

Issued by Government Departments · Kolkata, West Bengal
Tender Value
2.66 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Gem

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Not Available
Quantity
54

Project Description

Bids Are invited for Air Conditioning Work At Golf Green Residential Complex Supply - Supply Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu) I/C Drain Pipe R-32/R-410/ R-407 Green Refrigerant,Wireless Remote Control, Suitable For Working Between 180 To 260V With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100 Percent Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/International Electrotechnical Commission (Iec) 60730,Hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Iseer Value Must Be Minimum Of 5.6.The Ac Must Have 2026 Manufacturing Year The System Shall Be Able To Operate Up To 50 Degree C (Out Door Ambient Temperature).Inverter Type - Cooling Only 1 Tr With 5 Star Bee Rating Ac Make,-Hitachi/Voltas/Bluestar/Daikin /Lg/Panasonic. , Installation Testing And Commissioning - Installation Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu) I/C Drain Pipe R-32/R-410/ R-407 Green Refrigerant,Wireless Remote Control, Suitable For Working Between 180 To 260V With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100 Percent Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/International Electrotechnical Commission (Iec) 60730,Hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Iseer Value Must Be Minimum Of 5.6.The Ac Must Have 2026 Manufacturing Year The System Shall Be Able To Operate Up To 50 Degree C (Out Door Ambient Temperature).Inverter Type - Cooling Only 1 Tr With 5 Star Bee Rating Ac Make,-Hitachi/Voltas/Bluestar/Daikin /Lg/Panasonic. , Additional Copper Refrigerant Pipe And Additional Cable - Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulated With Xple Class-O Tubular Insulation/With Class-O Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, All Accessoriesas Per Specifications Etc. As Required 6.4 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm And 12.7 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 1 Tr Hi - Wall Split With Addtional Necessary Cables. , Additional Drain Pipe - Supply And Fixing Of Duly Insulated 25Mm Upvc Additional Drain Pipe , Outdoor Stand - Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 1 Tr Hi-Wall Split Ac.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 20-Aug-2026 24-Aug-2026

BOQ

Sl. No. Item TitleItem Description
1SupplySupply of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180 to 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100 percent of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. ISEER value must be minimum of 5.6.The AC must have 2026 manufacturing year The system shall be able to operate up to 50 Degree C (out door ambient temperature).Inverter Type - Cooling only 1 TR with 5 Star BEE Rating AC Make,-Hitachi/Voltas/Bluestar/Daikin /LG/Panasonic.
2Installation Testing and CommissioningInstallation Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete withIndoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant,wireless Remote control, suitable for working between 180 to 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100 percent of the rated capacity upto 42 Degree C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730,hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. ISEER value must be minimum of 5.6.The AC must have 2026 manufacturing year The system shall be able to operate up to 50 Degree C (out door ambient temperature).Inverter Type - Cooling only 1 TR with 5 Star BEE Rating AC Make,-Hitachi/Voltas/Bluestar/Daikin /LG/Panasonic.
3Additional copper refrigerant Pipe and additional cableSupplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for above system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessoriesas per specifications etc. as required 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm and 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm for 1 TR HI - WALL SPLIT with addtional necessary cables.
4Additional Drain PipeSupply and fixing of duly insulated 25mm UPVC additional drain pipe
5Outdoor StandSupplying , Installation, Testing and Commissioning of outdoor frame / stands to withstand the full load of outdoor units and making good all the damage for 1 TR Hi-Wall Split AC.

AI Tender Summary

OUR REF NO 56933001
AUTHORITY Government Departments
TENDER VALUE 2.66 Lakhs
LAST DATE 24-08-2026
Authority
Authority Name State Bank Of India
Work Description Bids Are invited for Air Conditioning Work At Golf Green Residential Complex Supply - Supply Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu) I/C Drain Pipe R-32/R-410/ R-407 Green Refrigerant,Wireless Remote Control, Suitable For Working Between 180 To 260V With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100 Percent Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/International Electrotechnical Commission (Iec) 60730,Hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Iseer Value Must Be Minimum Of 5.6.The Ac Must Have 2026 Manufacturing Year The System Shall Be Able To Operate Up To 50 Degree C (Out Door Ambient Temperature).Inverter Type - Cooling Only 1 Tr With 5 Star Bee Rating Ac Make,-Hitachi/Voltas/Bluestar/Daikin /Lg/Panasonic. , Installation Testing And Commissioning - Installation Testing And Commissioning Of Air Cooled Hi Wall Split Type Air Conditioners Complete Withindoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr(Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu) I/C Drain Pipe R-32/R-410/ R-407 Green Refrigerant,Wireless Remote Control, Suitable For Working Between 180 To 260V With Low & High Voltage Cutoff And 50 Hz ,1 Phase Ac Supply Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. The System Shall Be Able To Deliver 100 Percent Of The Rated Capacity Upto 42 Degree C. Min 5 Year Original Equipment Manufacturer (Oem) Warranty Both Compressor And Printed Circuit Board (Pcb). Must Comply Electrical Cable Is 694 Or Is 9968 Temperature Sensing Control Is/International Electrotechnical Commission (Iec) 60730,Hermetic Compressor Is 10617, Heat Exchanger Is 11329, Capacitor Is 2993 And Motor Is 12615. Iseer Value Must Be Minimum Of 5.6.The Ac Must Have 2026 Manufacturing Year The System Shall Be Able To Operate Up To 50 Degree C (Out Door Ambient Temperature).Inverter Type - Cooling Only 1 Tr With 5 Star Bee Rating Ac Make,-Hitachi/Voltas/Bluestar/Daikin /Lg/Panasonic. , Additional Copper Refrigerant Pipe And Additional Cable - Supplying, Installation, Testing And Commissioning Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping For Above System, Complete With Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulated With Xple Class-O Tubular Insulation/With Class-O Closed Cell Elastometric Nitrile Rubber Tubular Sleeves Sections Of 19 Mm Thick Insulation As Given Below For Suction And Liquid Lines, All Accessoriesas Per Specifications Etc. As Required 6.4 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm And 12.7 Mm Dia (Od) (Soft Drawn) With Tube Thickness 1.2 Mm For 1 Tr Hi - Wall Split With Addtional Necessary Cables. , Additional Drain Pipe - Supply And Fixing Of Duly Insulated 25Mm Upvc Additional Drain Pipe , Outdoor Stand - Supplying , Installation, Testing And Commissioning Of Outdoor Frame / Stands To Withstand The Full Load Of Outdoor Units And Making Good All The Damage For 1 Tr Hi-Wall Split Ac.
Basic Detail
Tender No GEM/2026/B/7897153
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 20 Aug 2026
Submission Date 24 Aug 2026
Open Date 24 Aug 2026
Finance
Tender Value 2.66 Lakhs
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
b68deb6c-764d-40a1-8217-81c255720771.pdf
9732718_Boq_1.xlsx
GOLFGREEN_5c79be65-e8f3-4d6c-bc791786348130269_SBILHO3970.BUY78.pdf
nit_for_ac_golf_green_2026-08-10-11-51-16_1e49bd7698bddaa9d65866043448e6c9.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 20, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 24, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Today
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Today
Aug 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Today

Tender Documents

Download All (ZIP) ↓
pdf

b68deb6c-764d-40a1-8217-81c255720771.pdf

xlsx

9732718_Boq_1.xlsx

BUY78

GOLFGREEN_5c79be65-e8f3-4d6c-bc791786348130269_SBILHO3970.BUY78.pdf

pdf

nit_for_ac_golf_green_2026-08-10-11-51-16_1e49bd7698bddaa9d65866043448e6c9.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders