Tender For Supply, Installation, Testing And Commissioning Of Data & Voice Networking, Cctv Surveillance System, Access Control System & Public Address System At Hbl Ivc Facility, Chengalpattu, Tamilnadu
Tender Value
30.34 Lakhs
Estimated cost
Bid Submission
19 Aug 2026
8 days left
EMD
75900
Bank guarantee accepted
Document Fee
1770
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Chengalpattu → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Supply, Installation, Testing And Commissioning Of Data & Voice Networking, Cctv Surveillance System, Access Control System & Public Address System At Hbl Ivc Facility, Chengalpattu, Tamilnadu
BOQ
| Sl. No. | Item Description |
| 1 | IT System :- |
| 2 | All Passive Components must be from same Manufacturer |
| 3 | Telephone & Data wiring :- |
| 4 | All telephone wiring shall be carried out using Cat6 Cable and Data Wiring shall be carried out using Cat6A cable in MS Conduits |
| 5 | MS Conduits and Raceway will be paid extra in Item No.5.1.3 |
| 6 | Supply & Laying of CAT6A Data wire (U/FTP Cable , up to 650 MHz ) |
| 7 | Laying |
| 8 | Supply & Laying of CAT6 Data wire (U/UTP Cable , up to 450 MHz ) |
| 9 | Laying |
| 10 | SUPPLY AND INSTALLATION OF PATCH CORD :- |
| 11 | Supply and Instllation of Patch cord betweeen Patch panel and Netwrok switch , Switch ,Patch cord between Network outlets and CPU/Laptop. |
| 12 | 1 Mtr. Cat6A Patch cord between Patch Panel and Network switch for Data (Patch Cord, S/FTP 4P, LSFRZH, Real10 Cat.6A, length 1.0 m) |
| 13 | 1 Mtr. Cat6 Patch cord between Patch Panel and Resource Patch Panel for Telephon System (Patch Cord, U/UTP 4P, Cat.6, length 1.0/ 2.0 m ) |
| 14 | 2 Mtr. Cat6A Patch cord between CPU/Laptop and Network outlets (Patch Cord, S/FTP 4P, LSFRZH, Real10 Cat.6A, length 2.0m ) |
| 15 | Supply and laying of Multi mode OFC Cable OM3 , Scope also includes supply and installation of suitable size HDPE pipe for OFC Cable protection |
| 16 | Supply and installation of 12 CORE OFC Cable/ Required Pigtail & Patch cords |
| 17 | 32 MM HDPE pipe |
| 18 | Laying of OFC |
| 19 | Laying of HDPE |
| 20 | Supply and installation of Network rack |
| 21 | Supply and installation of Network rack Model :- Floor Mounting type 24U w800mm * d800mm with 24U Glass door , 2U standard rack mount power distribution unit with 6 Nos. X 5 Amp 5 Pin 230 Volts AC, Inlet Plug type 6A Indian Round Pin-PDU Rating 8A- 2Sets , Cantilever shelf/type2/1U , Horizontal cable Manager /1U/Loop , Fan as per required CFM , 24 Port LIU fulley loaded with LC Coupler , plate pigtail , spicing kits & Fiber (OFC) LC ptach cords- 2Mtr. SM Pigtail , SM LC to LC Patch card 2Mtrs and Cat6A Ptach cords ect. Also all required mounting Hardware |
| 22 | INSTALLATION rack |
| 23 | Supply and installation of Patch panel (UNLOADED ) |
| 24 | Patch panel with integrated cable tie shelf, 19\\" fastening kit, labeling field, accepting the snap-in type color coding clips in 8 colors. Material: sub-rack made of sheet steel (DC01A) 1.5 mm, color blue chromatized, screen made of plastic (ABS), halogen-free, color medium gray (NCS 2502-B). Information Outlet or connectin module should comply with the specification mentioned above in 1.2 Mounting dimensions 14.9 x 19.5 mm, max. material thickness 1.6 mm. |
| 25 | Supply and installation of Patch Panel :- 24 port |
| 26 | Supply and installation of Krone Type Junction box |
| 27 | 100 Pair Krone Type Junction box |
| 28 | Supply & Installation of Heavy duty MS conduits and Floor Raceway |
| 29 | Supply & Installation of Heavy duty MS conduits |
| 30 | 19 mm dia MS Conduits |
| 31 | Laying |
| 32 | 25 mm dia MS Conduits |
| 33 | Laying |
| 34 | 40 mm dia MS Conduits |
| 35 | Supply & Installation of Floor Raceway (GI Powder coated ) |
| 36 | Supply & installation of Floor raceways fabricated out of GI Powedercoated of thickness 2.0 mm for the duct and accessories complete with necessary duct connector , Vertical and Horizontal bends, Tees , Fastening clamp , end cap suitable sized adjustable junction boxes at regular intervals of every 5 Mtrs as well as wherever connection to be required on Table and other accessories etc. as required, powder coated with 10/15 micron thick and finish shall be as per approval of the consultants / clients before fabrication. |
| 37 | Floor Raceway :- 250 mm Width x 38 mm Height in two compartment |
| 38 | Fixing |
| 39 | Floor Raceway :- 250 mm Width x 28 mm Height in two compartment |
| 40 | Fixing |
| 41 | SUPPLY & INSTALLATION OF SWITCHES/ SWITCH SOCKETs/RJ45:- |
| 42 | Supply, Assembly and installation of Switch and Switch sockets with necessary number of box, front and rear plate , switches, switch sockets, RJ45 & blank plates. All civil work includes in this item Scope includes fixing of screw cover & marking identification numbers & interconnections as per standard drawing, site requirement & direction of Engineer-In-charge. Also RJ45 Data/Voice point shall be criped by authorised and trained technician |
| 43 | SUPPLY & INSTALLATION OF SWITCH BOXES AND SWITCH SOCKET (SURFACE MOUNTING TYPE):- |
| 44 | The Switches and Socket outlets shall be surface mounted on Modular partition wall / on Furniture / On Floor Raceways /Wall raceways / Brick wall and front plate shall be poly carbonate type. |
| 45 | 10 Amp Switch 1 nos. in 1/2 module CRCA box with front & rear plate. |
| 46 | 10 Amp Switch 2 nos. in 2 module CRCA box with front & rear plate. |
| 47 | 10 Amp Switch 3 nos. in 3 module CRCA box with front & rear plate. |
| 48 | 6/16 Amp Switch socket 1 nos. in 3 module CRCA box with front & rear plate. (\\"I\\" type socket outlets) |
| 49 | \\"RJ 45 I/O 1 Nos. in CRCA box with front & rear plate.(Tt type Legend) (,CAT6 1 x RJ45, unshielded - 1 Nos.) |
| 50 | SUPPLY & INSTALLATION OF SWITCH BOXES AND SWITCH SOCKET ( CONCEALED IN WALL/PARTITION ) :- |
| 51 | The Switches and Socket outlets shall be concealed on Modular partition wall / on Furniture / On Floor Raceways /Wall raceways / Brick wall and front plate shall be poly carbonate type. |
| 52 | 10 Amp Switch 1 nos. in 1/2 module CRCA box with front & rear plate. |
| 53 | 10 Amp Switch 2 nos. in 2 module CRCA box with front & rear plate. |
| 54 | 10 Amp Switch 3 nos. in 3 module CRCA box with front & rear plate. |
| 55 | 10 Amp Two Way Switch 1 nos. in 1/2 module CRCA box with front & rear plate. |
| 56 | 6/16 Amp Switch socket 1 nos. in 3 module CRCA box with front & rear plate. (\\"F & UF&AC\\" type socket outlets) |
| 57 | 6/16 Amp Switch socket 2 nos. in 6 module CRCA box with front & rear plate.(\\"F1/F2 & UF1/UF2 type socket outlets). |
| 58 | 6/16 Amp Socket 9 nos. with 1 Nos. of Switch (6+6+4+3) CRCA box with front & rear plate.(\\"UPS1 type socket outlets). |
| 59 | \\"RJ 45 I/O 3 Nos. in CRCA box with front & rear plate (Dn type legend). (CAT6A 1 x RJ45, shielded- 3Nos.) |
| 60 | \\"RJ 45 I/O 2 Nos. in CRCA box with front & rear plate.(DnTn type legend). (CAT6 1 x RJ45, unshielded- 1 Nos., ,CAT6A 1 x RJ45, shielded- 1Nos.) |
| 61 | \\"RJ 45 I/O 1 Nos. in CRCA box with front & rear plate (Dn type legend). ( CAT6A 1 x RJ45, shielded- 1Nos.) |
| 62 | \\"RJ 45 I/O 1 Nos. in CRCA box with front & rear plate.(Tn type Legend) (CAT6 1 x RJ45, unshielded- 1 Nos) |
| 63 | INSTALLATION CONSEALED IN BRICK WALL/MODULAR WALL ( SS 304 MATT FINISH ):- |
| 64 | Switch , Socket outlets and Data outlets shall be housed in box/enclosure. The enclosure shall be made from CRCA and front cover plate shall be made from SS 304. The whole assembly shall be concealed in such a way that the SS 304 front cover plate is properly aligned & flush with the wall. The SS 304 Cover Plate shall be matt finish. |
| 65 | 10 Amp Switch 1 nos. in 1/2 module CRCA box with front & rear plate. |
| 66 | 10 Amp Switch 2 nos. in 2 module CRCA box with front & rear plate. |
| 67 | 10 Amp Switch 3 nos. in 3 module CRCA box with front & rear plate. |
| 68 | 10 Amp Two Way Switch 1 nos. in 1/2 module CRCA box with front & rear plate. |
| 69 | 6/16 Amp Switch socket 1 nos. in 3 module CRCA box with front & rear plate. (\\"C\\" & \\"UC\\" type socket outlets) |
| 70 | 6/16 Amp Switch socket 2 nos. in 6 module CRCA box with front & rear plate.(U1/U2 & UC1/UC2 type socket outlets) |
| 71 | \\"RJ 45 I/O 2 Nos. in CRCA box with front & rear plate.(DcTc type legend). (CAT6 1 x RJ45, unshielded- 1 Nos., ,CAT6A 1 x RJ45, shielded- 1Nos.) |
| 72 | \\"RJ 45 I/O 1 Nos. in CRCA box with front & rear plate (Dc type legend). ( CAT6A 1 x RJ45, shielded- 1Nos.) |
| 73 | \\"RJ 45 I/O 1 Nos. in CRCA box with front & rear plate.(Tc type Legend) (CAT6 1 x RJ45, unshielded- 1 Nos) |
| 74 | Card base Door Controller with PoE and IP65 including License Dongle 200, Centra Platform, PLT 100, TAM 100, FR 100, Exit Switch and EM Lock (20 Doors with 100 Users) |
| 75 | Installation, Testing and Commissioning of Complete System |
| 76 | Distriubuted L3 switchs configuration |
| 77 | cctv cam fixing and installation Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 19, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 8 daysAug 20, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender