Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #56929950

Tender For Provn Of Fire Alarm System And Smoke Detection System At Certain Locations At Af Stn Faridabad Under Ge (Af) Faridabad

Issued by Statutory Bodies & Commissions/Committees · Faridabad, Haryana
Tender Value
42.41 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
13 days left
EMD
84830
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Faridabad → Haryana
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Fire Alarm System And Smoke Detection System At Certain Locations At Af Stn Faridabad Under Ge (Af) Faridabad

BOQ

Name of Work:- PROVN OF FIRE ALARM SYSTEM AND SMOKE DETECTION SYSTEM AT CERTAIN LOCATIONS AT AF STN FARIDABAD UNDER GE (AF) FARIDABAD
Sl. No. Item Description
1Supply,Installation,Testing & Commissioning of 1 loop Analog Addressable fire Panel with following Features :- Each loop shall have a capacity of minimum 250 addressable devices excluding 20% spare. Expandable upto 30loops with supporting CPU/CPUs & power supply installed in Panel Failure of one loop card shuld not fail other loop (Virtual/Dual loop cards not allowed) Inbuilt 6 NAC Port to power Hooter strobe Peer to peer Networkable, support distributed loop architecture and Provision for remote monitoring through mobile app on a cloud Automatic battery charger for 24V SMF batteries sufficient for 24 hours normal working and 30 mins for Alarm The unit should be UL listed and FM approved complete as per specifications all complete all as specified and directed.
2Supply,Installation,Testing & Commissioning of 2 loop Analog Addressable fire Panel with following Features :- Each loop shall have a capacity of minimum 250 addressable devices excluding 20% spare. Expandable upto 30loops with supporting CPU/CPUs & power supply installed in Panel Failure of one loop card shuld not fail other loop (Virtual/Dual loop cards not allowed) Inbuilt 6 NAC Port to power Hooter strobe Peer to peer Networkable, support distributed loop architecture and Provision for remote monitoring through mobile app on a cloud Automatic battery charger for 24V SMF batteries sufficient for 24 hours normal working and 30 mins for Alarm The unit should be UL listed and FM approved complete as per specifications all complete complete all as specified and directed.
3Supply, installation, testing and commissioning of Active Repeater Panel with backlit Liquid Crystal Display & Reset, Silence & Acknowledge function, ZXR-A to connect all Control panel with all fittings & accessories. The unit should be UL listed and FM approved complete as per specifications complete all as specified and directed.
4Supply, installation, testing & Commissioning of Battery SMFLead acid 18AH 12 Volt complete all as specified and directed.
5Supply, Installation, Testing and Commissioning of Addressable Mulicriteria Detector (Heat cum Smoke), Address Switch to programme the modules,complete all as specified and directed.
6Supply, Installation, Testing & Commissioning of Addressable Muliti-sensor Detector (smoke & heat) with following features :-Smoke Sensitivity min 0.5% obs/ft for detecting Grey smoke. Dual Thermistors for Thermal activation at 57 Deg C Field adjustable min 3 levels of Alarm Setting Addressing using basic hand tools Bicolor LED with 360 deg view.The unit should be UL listed and FM approved complete as per specifications complete all as specified and directed.
7Supply, Installation, Testing & Commissioning of Isolator Module with following features Isolate short circuits with automatic resetting arrangement LED Blinking in normal state & get steady on activation Addressing using basic hand tools The unit should be UL listed and FM approved complete as per specifications complete all as specified and directed.
8Supply, Installation, Testing & Commissioning of Addressable Output Module for 3rd Party integration with followingm features Dual Pot. free contact rated 24v DC, 2A LED Blinking in normal state & get steady on activation Addressing using basic hand tools The unit should be UL listed and FM approved complete as per specifications complete all as specified and directed.
9Supply, Installation, Testing & Commissioning of Addressable Manual Call point with following features Bicolor LED monitor the heath status of the device LED Blinking in normal state & get steady on activation Test Key for manual testing Addressing using basic hand tools The unit should be UL listed and FM approved complete as per specifications complete all as specified and directed.
10Supply, Installation, Testing & Commissioning of Hooter cum Strobe with following features Sound level 80 dBA @ 3m for Audible annunciation Visual - 115cd flashing at 1 Hz Wall/Ceiling Mountable The unit should be UL listed complete as per specifications complete all as specified and directed.
11Supply & Installation of Back Box for Installation of MCP complete all as specified and directed.
12Supply & installation of Response Indicator to provide the indication of alarm activated condition of detector installed in a concealed enlosure or not visible directly complete all as specified and directed.
13Supply, Installation, Testing and Commissioning of 2C x 1.5 sq.mm, copper armoured cable FRLS complete with all fittings & accessories complete all as specified and directed.
14Supply & Installation of MS Junction Box for Installation of Detector at Roof Surface complete all as specified and directed.
15Supply & Installation of PVC Conduit Pipe 32mm dia with 32mm saddle & other accessories complete all as specified and directed.
16Supply & Installation of PVC Channel/ Batterm 25mm X 25mm with saddle & other accessories complete all as specified and directed.
17Supply, Installation, Testing and Commissioning of 50mm x 50mm x 2mm GI Perforated type cable trays factory fabricated out of sheet steel with perforation not more than 17.5%, supporting angle frame at every 1.5 m, bottom angle fasteners, anchor grip bolts, etc. The tray shall be suspended from ceiling using anchor bolt and angle iron supports or mounted from wall complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56929950
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 42.41 Lakhs
LAST DATE 31-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Fire Alarm System And Smoke Detection System At Certain Locations At Af Stn Faridabad Under Ge (Af) Faridabad
Basic Detail
Tender No CWE/GGN/FT-07/2026-27
Bidding Type Tender
Location
City Faridabad
State Haryana
Key Dates
Publish Date 10 Aug 2026
Submission Date 31 Aug 2026
Open Date 02 Sep 2026
Finance
Tender Value 42.41 Lakhs
Tender Fee 500
EMD 84830
Exemption Available
Document List
0abca95c-e71d-4f6d-82fd-422adec9e5b2.html
BOQ_877980.xls
TDFT07.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Sep 02, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

0abca95c-e71d-4f6d-82fd-422adec9e5b2.html

xls

BOQ_877980.xls

pdf

TDFT07.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders