Agriculture Government Departments Closing in 5 days TDR #56928478

Tender For C Us Light, Repair Of Godown Sheets, Plaster, Painting, G.I Sheet, Entry Gate Etc. At Mahrajganj (Raebareli)

Issued by Government Departments · Rae Bareli, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
19 Aug 2026
5 days left
EMD
23200
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rae Bareli → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for C Us Light, Repair Of Godown Sheets, Plaster, Painting, G.I Sheet, Entry Gate Etc. At Mahrajganj (Raebareli)

BOQ

Name of Work:- C us Light, Repair of Godown Sheets, Plaster, Painting, G.I Sheet, Entry Gate Etc. At Mahrajganj (Raebareli)
Sl. No. Item Description
1Campus and Godown Light
2LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt). Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) 135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).120 watt
3Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
4Providing and Fixing 25 sqmm 3 core Aluminium Armoured Power Cable all complete.On existing wall/surface or In the existing RCC/ HUME/ METAL pipe or In the existing masonry open duct/loose/connection
5Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)6 way , Double door
6Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
7Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
8Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 50 mm dia nominal bore
9Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
10Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
11Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm
12Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
13LED Batten light (System lumen efficacy ≥105 85%, Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10%, P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) 1.20 mm) 18-22 Watt
14Repair of Godown
15Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
1612 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand)
17Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete
18Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
19Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
20White washing with lime to give an even shade : New work (three or more coats)
21Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work
22Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard gates and similar works bar, ladder, railings, brackets, Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56928478
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 19-08-2026
Authority
Authority Name Uttar Pradesh State Warehousing Corporation Limited
Work Description Tender for C Us Light, Repair Of Godown Sheets, Plaster, Painting, G.I Sheet, Entry Gate Etc. At Mahrajganj (Raebareli)
Basic Detail
Tender No 20260829140
Bidding Type Tender
Location
City Rae Bareli
State Uttar Pradesh
Key Dates
Publish Date 10 Aug 2026
Submission Date 19 Aug 2026
Open Date 19 Aug 2026
Finance
Tender Value Ref. Documents
Tender Fee 1180
EMD 23200
Exemption Not Available
Document List
BOQ_2209106.xls
ed018ad2-3a75-4f9d-ae2f-5d70e74175a1.html
MTF.pdf
Tendernotice_1 (35).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 19, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 5 days
Aug 19, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_2209106.xls

html

ed018ad2-3a75-4f9d-ae2f-5d70e74175a1.html

pdf

MTF.pdf

pdf

Tendernotice_1 (35).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders