Tender for Renovation, Modernization And Up-Gradation Of Bbmb Hospital Nangal.
BOQ
| Sl. No. | Item Description |
| 1 | PART-A Civil Works Items |
| 2 | WATER PROOFING WORK AT TERRACE AREA: Surface Preparation: Existing Surfaces must be clean, even, and sound concrete. Remove oil, dirt, laitance. Crack treatment: Cutting and opening cracks to a depth of 10x10 mm V or U Shape by mechanical means. Cleaning al the dirt and loose particles by air pressure and wetting crack to attain SSD condition. filling the crack using Repair Polymer modified cement mortar. Bore Packing: Using AP Smartcare Repair Polymer over pipe and Internal side of concrete followed by filing high strength non shrink grout for a gap of up to 20mm (between pipe and concrete) before treating the surface with Waterproofing layer. Supplying and applying SmartCare Damp Proof Ultra, fiber reinforced elastomeric liquid waterproofing membrane formulated with PU hybrid polymers and reinforcing acrylic fibers with Sun Reflectivity Index (SRI) of 105 on top of roof in three coats @ 1.2 litre/sqmt to be reinforced, having minimum elongation of 350%, tensile strength 2.9Mpa and shall have crack bridging ability of up to 2.5mm and shall resist 10bars of hydrostatic pressure, reduces surfaces temperature up to 10 degree Celsius also IGBC certified (Indian Green Building Council) Certificate will be provided by company. The system consists of self priming with 33% water dilution followed by two undiluted coats of Damp Proof ultra , the fibre mesh of 40 to 50 GSM must be sandwich between 1st and 2nd coat of Damp Proof Ultra. (dry film thickness of complete application/system not less than 500 microns) and Ponding test to be done after application of material.( MR). |
| 3 | Cement concrete 1:2:4 With stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type( CSR item No. 10.13(A)(ii)). |
| 4 | Dismantling concrete Cement concrete plain1:2:4 mix (CSR Item No. (CSR 8.6)(d)). |
| 5 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. (CSR Item No. 13.55). |
| 6 | Top Khurra 0.6mx0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50.00thick cement concrete 1:8:16 (CSR Item No. 13.45) . |
| 7 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material within 50meters lead as directed by Engineer-in-charge(CSR Item No. 8.44). |
| 8 | providing and fixing 110 mm dia SWR U.P.V.C Rain water pipe of 4 kg /sqm (ring fitted type-A) as per IS 4985 includning jointing during masonry complete as per speifications and the entire satisification of EIC (CSR item No. 13.74 ) . |
| 9 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. (a) UPVC 110 mm bend(CSR Item No.13.75(a)). |
| 10 | Providing & fixing in position MS or heavy flat iron clamps made out of MS flat iron not less than 5mm of the approved design for fixing CI soil waste, vent or antisyhonage pipes to walls compete in all respects including cutting land making good the walls and floors etc. and painting a) MS holder bats clamps for 100mm i/d HCI pipes.(CSR item no. 30.78 (a)). |
| 11 | Removing Doors and Windows (Steel or wood) with chowkhats by making recesses in walls when the wall is not to be dismantled. Doors of area 3 sqm and below (L/R) (CSR item no. 8.26 (a)). |
| 12 | Windows of area 3 sqm and below (L/R)(CSR Item No.8.26(b)). |
| 13 | Clerestory windows of area 3 sqm and below (L/R)(CSR Item No.8.26(c )). |
| 14 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shopdraw ings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken for purpose of payment.(CSR Item No. 17.106) . |
| 15 | Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminum snap beading shall be paid in basic item) I)Float glass panes of 5 mm thickness ( CSR item no. 17.47-( i ) ). |
| 16 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc.complete as per architectural drawings and directions of Engineer-In-Charge. Pre-laminated particle board with decorative lamination on Both side. ( CSR Item no. 17.46-ii)). |
| 17 | Providing and fixing aluminum sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc.complete: A) 300mm x 16mm (CSR Item no. 17.49-A). |
| 18 | cost of aluminium fittings complete for doors, windows such as a tower bolts, handless stopper and screw etc. for this fittings ( excluding sliding bolt) (ii ) for shutter area above 0.50 sqm ( CSR item no. 17.23-ii) . |
| 19 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. complete (c) I.S.I Designation No. III (size of door 851mm to 1000mm) {CSR Item no. 17.43 (c )}. |
| 20 | Providing and fixing double action hydraulic floor springof approvedbrand andmanufacture IS :6315 marked, for doors including cost of cutting floors as required, embedding in floors andcover plates with brass pivot and single piece MS sheet outer box with slide plate and with stainless steel cover plate etc. complete as per the direction of Engineerin-charge.(CSR Item No. 17.48). |
| 21 | Providing and fixing aluminum Wire Mesh including cost of necessary fittings i.e. screws,u Type Beading etc. complete(CSR 17.96). |
| 22 | Providing and fixing aluminumgrill 6.3mm including cost of necessary fittingsi.e. screws,u Type Beading etc. complete.(CSR Item No. 17.94). |
| 23 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.(CSR Item No.11.4i). |
| 24 | Scraping:- Cement Plaster (L/R) ( CSR Item no. 8.31 ( c )) (Actual measurement at site). |
| 25 | 12.5mm thick cement plaster 1:4 (CSR Item No.15.9). |
| 26 | Preparation of plasteredor concrete surface for painting (including sand papering the surface)using Acryllic Wall Putty by applying two or more coats to get required finish Including priming coat to make an even surface Before applying Acrylic wall putty on new plastered surface.Complete as per specifications (CSR Item No.R 16.73). |
| 27 | Wall painting with(biograde )plastic emulsion paint of approved brandand manufacturer to give an even shade (two or more coats)Generally used in hospital buildings etc Complete as per Specifications (CSR Item No.16.76). |
| 28 | Washed stone grit plaster on exterior walls of height upto10M. above ground level in two layers, under layer 12.5mm cement plaster1:4(1cement : 4coarse sand ) 14 furrawing coarse sand : 2stone chipping 10mmnominal size) in panels with groove all around Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2the under layer with scratching tool, applying cement slurry on the under layer@2 as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings, complete as per specification and direction of Engineer-in-charge (Payment for providing grooves shall be made separately). (CSR Item No.15.70) |
| 29 | Forming groove of uniform size in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete as per specifications and direction of the Engineer-in-charge : 15 mm wide and 15 mm deep groove(CSR Item No. 15.71) . (Actual measurement at site). |
| 30 | Finishing walls with textured exterior paint of required shade with two or more coats applied @3.28 litre/10Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm (CSR Item No. 16.58). |
| 31 | Providing and fixing tiled false ceiling at height up to 4meter of specified materials of size 595x595mm (GI Metal Ceiling Lay in perforated teguler edge global white color tiles of size 595x595 mm and 0.5mm thick with 8mm drop ;made of GI sheet having galvanizing of 100gms/sqm (both sides inclusive) and 20% perforation area with 1.8mm dia holes and having NRC (Noise Reduction Coefficient )of 0.5,electro statically polyester powder coated of thickness 60microns (minimum), including factory painted after bending and perforation ,and backed with a black Glass fiber acoustical fleece.) in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120grams/sqm, both side inclusive)consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38mm made from 0.30mm thick (minimum) sheet, spaced at 1200mm center to center and cross \\"T\\" of size 24x25mm made of 0.30mm thick (minimum) sheet, 1200mm long spaced between main \\"T\\" at 600mm center to center to form a grid of 1200x600mm and secondary cross \\"T\\" of length 600mm and size 24x25mm made of 0.30 mm thick (minimum) sheet to be inter locked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size24x24x0.3mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with12.5mm dia and 50mm longdash fasteners, 4mm GI adjustable rods with galvanised butterfly level clips of size 85x30x0.8mm spaced at 1200mm center to center along main T,bottom exposed width of 24mm of all T sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawing sand as directed by Engineer-in-charge. (CSR Item No.13.81). |
| 32 | Dismantling of wall tiles at any floor of the building, laid in cement mortar including scraping of cement plaster and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect(CSR Item No. 30.94) |
| 33 | Dismantling of floor tiles at any floor of the building, laid in cement mortar includingdismantling of cement concrete base and disposal of malba at a suitable place within a distance of 100 Mtrs of the complex complete in all respect.(CSR Item No. 30.95). |
| 34 | Providing and fixing1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 600x600mmas approved by Engineer-in-Charge in skirting, risers of steps and dados over 12mmthickbedofcementMortar1:4(1cement: 4 finesand)andjointing with grey cement slurry @3.3kg per sqm including pointing in white cement mixed with pigment ofmatching shade complete(CSR Item No. 14.129). |
| 35 | Providing and fixing 1st. quality Glazed vitrified wall tiles/Anti Skid Floor Tiles (thickness to be specified by the manufacture of approved make in all colours, shades of size 4’x2’ feet as approved by Engineer-in-charge in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:4 (1 cement 4 coarse sand ) and joining with grey cement slurry @ 3.3 kg. per sqm. including pointing in white cement mixed with pigment of matching shade complete.(AOR). |
| 36 | Providing and laying vitrified floor tiles of different sizes in light colour shades made using Double Charge technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. a) Size 600x600 mm. ( CSR Item No. 14.113 (a)) . |
| 37 | Providing and Fixing ceiling at height upto 4Mtr consisting of 12.5mm thick Gypsum Board of any size G.I. Cradling hanged from the ceiling by means of G.I. hanger complete as per drawings, specifications and to the entire satisfaction of engineer-in- charge. (CSR Item No.13.65). |
| 38 | Ceiling Lights 600x600mm (MR). |
| 39 | Providing & fixing ACP Sheets of various thickness High Class ISI marked complete in all respect as per the directions of Engineer-in-charge (i) 6mm thick ACP Sheet(CSR Item No. 17.97(i)). |
| 40 | Earth work in excavation of foundations of bridges culverts, buildings including handling of material with a combined lead of 15 metres dressing of bed and sides stacking the excavated soil from the edge of excavation and subsequent filling around (a) For ordinary gravel soil involving pick work (Pb. CSR Ref. No. 6.7 (a)). |
| 41 | Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer–in-charge, upto 90 metre depth below ground level. B. Rocky Strata including Boulders (a) 400 mm dia. (Pb. CSR Ref. No.28.91 (B) (c)). |
| 42 | Supplying at site of gravel of 1/16\\" to 1/8\\" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from, dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per actual length of pipe) (Pb. CSR Ref. No. 28.88) . |
| 43 | Providing and placing in horizontal layers filtering media screened, washed and cleaned as described below:- Fourth Layer :----- (d) Bajri (Coarse) screened, cleaned and washed and graded from 20mm to 25mm (from Pathankot or approved equivalent quarry) (Pb. CSR Ref. No. 28.51(d)) . |
| 44 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. (c ) 200 mm nominal size dia.(CSR Item No. 28.93(c)) (T/R). |
| 45 | V\\" wire screen for injection well of diameter 163 MM `V ' Wire screen material SS 304 Screen, width of the profile V wire 2.57 MM x Profile wire Height 2.24 MM, support rod Dia 3.15 MMs, consisting of continuous trapezoidal wire spirally wound around fabricated cage. Slot Size 0.75 MM, collapse strength of pipe up to 3.70 Kg/Cm2, tensilestrength of pipe 10.70tones, & open area is 57% designed velocityat the entry of screen, less than 0.03 Meter Per second, end connections One Side Flat Screen with 0.75MM slots and other end with 150MM Sleeve - overall length with sleeve-750 MM. The work includes fixing the V-wire screen to the perforated vertical HDPE pipes of suitable dia. (N.S. item)(T/R) (MR). |
| 46 | 203 mm dia horizontal V- wire screen for silt trap made up of low carbonized steel cage treated with grit blasting, spray galvanizing with zinc metal coating. Zinc metal coating spraying should involve galvanizing (Thermal Spray Coating of Zinc - TSZ) i.e., depositing of molten zinc (Purity 99.5%) on to a prepared surface. The metal spraying is to be melted in an electric arc automized by compressed air and then projected onto the substrate for grit blasting as per IS & BS standards. IS 5905 IS 6586 BS: 5493 with - powder epoxy hybrid of thickness 40 to 60 microns and coating of the screen with anti-oxidant powder follows: Pattern on-screen wound on pipe consisting of continuous trapezoidal wire spirally wound around fabricated cage, Slot size 3mm, a tensile strength of screen 6 tons, collapse strength of screen up to 9.6 kg/cm2 slot opening size 70%. The effective length of the screen is 500 mm with end manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in Charge. (N.S. item) (T/R) (MR) |
| 47 | Providing and lowering of RCC M-25 Concrete Rings of 1800 mm dia, 55-70 mm thick and 300 mm high factory made complete in all respect. (N.S. item) (T/R)+ (19+1) to adjust any variation in-depth |
| 48 | Providing and lowering of RCC M-25 Concrete Rings of 1350 mm dia having a thickness of 65-75 mm for a height of 70 mm and 120-140 mm for a height of 230 mm, thus a total height of 300 mm factory made complete in all respect. (N.S. item) (T/R) (MR). |
| 49 | Provided and fixing of factory made RCC M25 perforated slab of 1.5 mtrs dia and 65 mm thick, having perforations in the slab so as the filtered rainwater from the filtration media can be percolated towards the rainwater harvesting well (N.S. item) (T/R)(MR). |
| 50 | Providing and fixing of factory made RCC M25 slabs for Rainwater harvesting well and the silt trap chamber of 1.5 mtrs dia and 65 mm thick, the slab for the rainwater harvesting well shall have a sleeve for the vent pipe and both slabs (N.S. item) (T/R) (MR). |
| 51 | Providing and laying Filtration Media consisting of 40 mm crushed stone, Charcoal, Activated Carbon and coarse sand. (N.S. item) (T/R) (MR) |
| 52 | Providing and laying, jointing, fixing and testing ISI Marked uPVC Pipe Lines as per ISI 4985-2000, including specials such as tees, bends, sockets, elbow etc., cutting, testing (including cost of specials) in the ground complete in all respects. (A) uPVC Pipe 10 Kgf/cm2 (e) 50mm i/d (Pb. CSR Ref. No. 28.12(A) (e)) (T/R) . |
| 53 | Providing and fixing of 6 inch dia uPVC flange along with tail piece in silt trap unit on 160 mm o/d uPVC pipe in order to connect the flanged 'V' wire filter complete in all respect (N.S. item) (T/R) (MR). |
| 54 | 12.5 mm thick cement plaster 1:3 (Pb. CSR Ref. No. 15.8) (T/R). |
| 55 | Dismantling concrete (d) Cement concrete plain1:2:4 mix (Pb. CSR Ref. No. 8.6(d)). |
| 56 | Providing, lowering in trenches to correct gradient and alignment, jointing with tylon rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as per IS code IS458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed.The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc. (D) R.C.C. Pipe NP -4 (e) 300MM i/d Pipe(Pb. CSR Ref. No. 29.46(d)(e). |
| 57 | Cement concrete 1:5:10 (b) With stone aggregate 40mm gauge (ii) mixing by mechanical means using concrete mixer volumetric type(Pb. CSR Ref. No. 10.9(b) (ii)) (T/R). |
| 58 | Cement concrete 1:2:4 With stone ballast or shingle mixing by mechanical means using concrete mixer volumetric type CSR 10.13(a)(ii). |
| 59 | Excavation manually in trenches with straight or open cutting in built upstreet/ lane having wall to wall width of street/ lane upto 3.0 metre, for intramural sullage drains, extra mural intercepting drains and out fall drains, storm water channels and other work contingent or incident there to, to full dimensions and depth as shown on the drawings or as shall be required by Engineer-in-charge including dressing to correct sections and dimensions according to templates and levels, dewatering of rain water,diversion of traffic. Providing and fixing and maintenance of caution boards, fencing, night signals, for ds upto 15m and for all lifts and subsequent refilling, watering and dressing upto ground level, including removal of surplus spoil from the site upto 15metre distance complete in all respects. (Pb. CSR Ref. No. 29.1 (A)(ii). |
| 60 | Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick C.C 1:6:12 in foundation, first class brick work laid in cement sand mortar 1:5, 40mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12.50mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1mm thick left absolutely smooth polished and correct to template including cost of precasted RCC road gully grating and frame including paint with coal tar (as specified in item No. 29.49) complete and to the requirement of the engineer in charge. (B)Double Road Gully Chamber (b) Size 1448mm x 457mm x 1105mm CSR 29.63(B)(b). |
| 61 | Maintenance of fine grass lawn for one year includingfertilizerapplication,watering,weeding, top dressing with good earth and manure mixture,maintaining fine level, regularmowing and removal of rubbish with all lifts and leads(CSR 32.10). |
| 62 | Fine grassing including up rooting rank vegetation and weeds by digging the area to a depth of 30cm, removing all weeds and other growth with roots by for king repeatedly, breaking clods, rough dressing, flooding with water, uprooting fresh growth after 10 to 15 days, mixing fertilizer and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts, watering, weeding and maintenance for 30 days or till thick lawn is formed (a) Planting Selection no. 1 grass roots in rows 5 cm apart in both directions.(CSR 32.9(a)). |
| 63 | Planting Rose beds including digging of beds to 15 cm depth and mixing FYM, fertilizer and insecticides, triangular planting of sapling at 60cm distance from plant to plant and row to row.(CSR 32.30) |
| 64 | Maintenance of Rose beds for one year including application of FYM, fertilizer, insecticides, pruning and casualty replacement(CSR 32.31) |
| 65 | Providing earthen pots at site of work, filling with mixture of screened manure, good earth and cocopeat in the ratio 2:1:1 as specified. (d) 30 cm size of pots filled to full volume(CSR 32.37(d)) |
| 66 | Providing cement pots at site of work, filling 2/3rd volumewithmixture of good earth and screened manure and cocopeat in the ratio 2:1:1. (c) 45 cm size of pots(CSR 32.38( c )). |
| 67 | Providing plastic pot with base plate at site of work, filling with mixture of good earth and screened manure and cocopeat in the ratio 2:1:1. (g) 45 cm size of pots filled to 2/3 of volume.(CSR 32.39(g)). |
| 68 | Maintenance of indoor pot plants for one year.(CSR 32.44). |
| 69 | Maintenance of ouydoor pot plants for one year.(CSR 32.48). |
| 70 | Supply and installation of garden bench (a) Chair type garden bench with L-shaped sides made of reinforced concrete (M30), thickness 100mm, overall height 1000 mm,base width 620mm.Back and seat shall consist of 5 Nos. reinforced concrete planks 1500mmx100mmx50 mm one plank 1500mmx200mmx50 mm.Seating height of the bench shall be 450mm. The bench shall be fixed with nuts on concrete mount,all holes sealed after assembly and installation(CSR32.57(a)). |
| 71 | Supply and installation of garden bench (b) Rectangular garden bench with h-shaped sides made of reinforced concrete (M30), thickness 100mm, back height 750 mm,base width 450mm.Back and seat shall consist of rectangular reinforced concrete planks 1500mmx350mmx50 mm.Seating height of the bench shall be 450mm. The bench shall be fixed with nuts on concrete mount,all holes sealed after assembly and installation (CSR item No.32.57(b)). |
| 72 | Supply and installation of garden bench(c) Cast Iron bench of 1800mm length,900 mm width,450mm seating height,sides made of cast iron.Seat and back shall be made of 10 strips of M.S. pipes 63mm x 25mm of 14 gauge with one M.S.Flat 25 x10 mm welded at the centre, below and back of the seat and back rest. Spray painted with approved brand paint.Fixed by grouting with1:2:4 cement concrete (Minimum weight of each bench 105 kg)(CSR item No.32.57(c)). |
| 73 | Dismantling brick work tile, masonry or tile lining (b) In cement (CSR item no. 8.5 b). |
| 74 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres.(CSR Item No. 6.6). |
| 75 | Cement Concrete 1:6:12 , with stone aggregate 40 mm gauge mixing by mechanical means using concrete mixture volumetric type.(CSR item No. 10.8 b (ii)). |
| 76 | Shuttring for faces of concrete foundations and foundation beams and plinth beam ( vertical or battering). (CSR item no. 9.1). |
| 77 | Centring and shuttring for columns (Squares or Rectangular or poly gonal in plan) in first story (upto 4 mtr height. ) (CSR item no 9.4). |
| 78 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels in first story (upto 4 mtr height). (CSR item no. 9.6 ). |
| 79 | RCC M-20 mechanically batch mixed using batch type concrete mixture as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centering and shuttering in foundation and plinth. (CSR item no 10.15). |
| 80 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in superstructure. (CSR item no. 10.20). |
| 81 | Cold twisted deformed (Ribbed/ Tor Steel Bar) Bars Fe 500 grade as per IS 1786-1985, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete. ( CSR Item no. 18.18 ). |
| 82 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. ( CSR Item no. 11.3 i ). |
| 83 | Damp proof course 4 cm thick of CC 1: 2: 4 with two coats of bitumen 20/30 penetration @ 1.65 kg per sqm laid hot and sanded. ( CSR Item no. 10.26 ). |
| 84 | 20mm thick cement plaster 1:6 in two coats work ( CSR Item no. 15.28 ). |
| 85 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface.(CSR item No. 16.31). |
| 86 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm (CSR item no. 16.60). |
| 87 | Scraping, e) Bricks dismantled from brick work in lime or cement. (CSR item no. 8.31 e). |
| 88 | Carriage of Bricks lead 1 km including loading & unloading including stacking.( CSR Item no. 5.2 (vi) & 4.3 ). |
| 89 | Carriage of Bricks Bats lead 1 km including loading. ( CSR Item no. 5.2 (i) & 4.1 A ). |
| 90 | Dismantling concrete (e) Reinforced cement concrete (CSR item 8.6 e). |
| 91 | Dismantling concrete (a) Lime concrete,cement concrete of1:6:12 or leaner mix (CSR item 8.6 a). |
| 92 | Centring and shuttring for columns (Squares or Rectangular or poly gonal in plan) in first story (upto 4 mtr to 5 mtr. height.) (CSR item no 9.4 & 9.16). |
| 93 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels in first story (4 to 6 mtr height). (CSR item no. 9.6 ). |
| 94 | Terracing consisting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg/sqm top of RCC slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing etc. (CSR Item 13.13 (i)). |
| 95 | Plastering on underside of ceiling 10 mm thick cement plaster 1:4 (upto 4 mtr. ) (CSR item no. 15.44). |
| 96 | Plastering on walls 6 mm thick cement plaster 1:4 ( 0 to 4 mtr) (CSR item no. 15.3). |
| 97 | 12.5 mm thick cement plaster 1:6 (upto 4 mtr) (CSR item no. 15.11). |
| 98 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 and 100mm sand filling. ( CSR item no 14.3). |
| 99 | Wall painting with plastic emulsion paint of approved brand and manufacturer to give an even shade (two coats) ( CSR item no. 16.64). |
| 100 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two coats applied @ 1.43 litre/10 sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm. (CSR Item no. 16.60). |
| 101 | Providing & Fixing of Soft Fiber Acoustical Suspended Ceiling System – of approved make acoustik soft Fiber Glass micro look/Square edge tile with 15mm Exposed Groove Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.90, Light Reflectance >84% with Fire Resistance in module size of 595 X 595 X 15 mm. The grid should 15mm grid sections i.e. the Main Runner 3000mm in 38 mm web height, 1200 mm & 600 mm Cross Tees in web height of 26mm with thickness 0.3mm, to comprise main runner spaced at 1200mm centre securely fixed to the structural soffit using suspension system at 1200mm maximum centre. The First/Last suspension system at the end of each main runner should not be greater than 450mm from the adjacent wall. Flush fitting 1200mm long cross tees to be interlocked between main runners at 600mm centre to form 1200 x 600 mm module. Cut cross tees longer than 600mm require independent support. 600 x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between the 1200 mm cross tees. Perimeter trim to be wall angles of size 3000x19x19mm, secured to walls at 450 mm maximum centres and as per the drawing and the work complete in all respects to the satisfaction of Engineer in-charge. All accessories consisting of Fasteners of thread size 6.5mm x 25/5 with Soffit Cleat made of Galvanised steel of size 27 x 37 x 25 x 1.6mm and Level Clip in dimensions of 85x30x0.8mm with 4.00 mm GI wire.(MR). |
| 102 | Providing & fixing of Wooden Slats Wall panelling Dexune /Pro Acoustic / Veils Dexi wood grooved panel having shall be fire resistance (FR) BS476 Part 7 with melamine laminate panel 2440mm x128mmx15mm with 2mm grooved at 14mm pitch, Tongue and grove adages for seamless mounting having density of 800 kg/m3 (based panel confirming to IS 12406 and laminated panel confirming to IS 114587) The black of the panels are perforated with a nonwoven fabric covering of 0.2 mm for providing Sound absorption via the acoustic impedance method. Dexune panel ids fixed by using GI Framework spaced at 600mm centres @ aluminium framework spaced at 400mm centres with suitable brackets or wood batten to maintain line length & level and the system is backline with 50 mm Roxul Rockwool and along with all accessories. Installation wooden battens (provided by others) of section 50mmx50mm or as approved by the Architect on the solid wall horizontally using screws and plugs at spacing of 600 mm centre-to- centre. Screw the aluminium extruded keel for channelled woodworks provided by manufacture over the lowest and second wooden batten at an on- centre distance of 600mm. Install the first set of wooden panels by inserting the clips for border channelled woodworks and insert the groove of the panel into the projecting flange of the aluminium clip. Continue installing rows of panels by inserting the tongue into the groove of the earlier inserted panel and progressively installing clips for inside channelled woodwork into the next keel till the actual height is achieved. Use clips for border channelled woodworks to finish off the installation. Finish off the edges using wooden moulding of matching colour. (AOR)(MR). |
| 103 | Providing design and fixing imported tensile Fabric of Weight not less than 650 GSM Fabric.Make Architectonic Belgium This should also include cutting ,welding and cables.Plates &necessary hardware for fixing the Fabric as approved shape as per drawing.Membrane shall be cut and manufactured with high frequency pvc welding machine.Fabric Warranty 10 Year (NS). |
| 104 | Steel work in built up tubular pipes (round, square or rectangular hollow tubes etc. ISI Marked) for flat shed (ie.Where no truss work is involved) including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.(NS). |
| 105 | Sensor Automated Door.(NS). |
| 106 | Chairs (teak wood cushioned chair) (MR). |
| 107 | Beds (6'x3')(MR). |
| 108 | Stool (revolving examination stool).(MR). |
| 109 | Benches Steel (3 seater).(MR). |
| 110 | Almira 4 big.(MR). |
| 111 | Almira 4 small.(MR). |
| 112 | A.V Stand .(MR). |
| 113 | Wheel Chair .(MR). |
| 114 | Steel rack(with 7 shelves) .(MR). |
| 115 | Examionation Table .(MR). |
| 116 | Delivery Table .(MR). |
| 117 | OT Table .(MR). |
| 118 | Computer Table 3'2 with computer having printer scanner(3'x2' ft with computer printer scanner ir processor,8gb ram,512gb rom) .(MR). |
| 119 | Scraping e) bricks dismantling from brick work (as per item no.8.31 (e)). |
| 120 | Carriage of Bricks lead 1 km including loading & unloading. (CSR Item no. 5.2 (vi) & 4.3). |
| 121 | Carriage of material (Earth, Surkhi. Sand, Earth, Fly Ash. Bajri. Ballast. Stone Boulders. Kankar and Building Rubbish, Earth) including loading and unloading (metaled roads)With lead up to 1.00 km. (CSR Item no. 5.2 (i) & 4.1 (a)). |
| 122 | PART-A Water Supply Items |
| 123 | Excavation manually in trenches with straight or open cutting in built up street/ lane havingmwall to wall width of street/ lane upto 3.0 metre, for intramural sullage drains, extramural intercepting drains and outfall drains, storm water channels and other work contingent or incident thereto, to full dimensions and depth as shown on the drawings or as shall be required by Engineer-in- charge including dressing to correct sections and dimensions according to templates and levels, dewatering of rain water, diversion of traffic. Providing and fixing and maintenance of caution boards, fencing, night signals, for leads upto 15m and for alllifts and subsequent refilling, watering and dressing upto groung level, including removal of surplus spoil from the site upto 15 metre distance complete in all respects. For Ordinary gravel soil having gravel upto 40% . (CSR item No,29.1 A (ii)). |
| 124 | Providing and fixing in position single socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B a)110mm o/d SWR UPVC pipe lines laid complete (CSR Item No.30.74) (B) (b)). |
| 125 | Providing and fixing in position single socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing. Single Socket Type B (b) 90 mm o/d SWR UPVC pipe lines laid complete. (CSR Item No.30.74) (B) (b)(iii)). |
| 126 | Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonge pipes as per IS-14735 of including cutting and wastage etc. cutting holes in walls roofs etc. and making good to its original condition but excluding cost of lead joining. B) or 110mm O/D pipe (i) vent cowel. (CSR item No.30.81 (iii) (B) (vi)). |
| 127 | Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonge pipes as per IS-14735 including cutting and wastage etc. cutting holes in walls roofs etc. and making good to its original condition but excluding cost of lead joining. B) or 110mm O/D pipe (ii) Coupler .(CSR item No.30.81 (iii) (B) (viii)). |
| 128 | Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonge pipes as per IS-14735 including cutting and wastage etc. cutting holes in walls roofs etc. and making good to its original condition but excluding cost of lead joining. B) or 110mm O/D pipe (iv) Door Elbow 90 Degree (all side socketed ).(CSR item No.30.81 (iii) (B) (iv)). |
| 129 | Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonge pipes as per IS-14735 including cutting and wastage etc. cutting holes in walls roofs etc. and making good to its original condition but excluding cost of lead joining. B) or 110mm O/D pipe (Iv) Single Tee. (CSR item No.30.81 (iii) (B) (v)). |
| 130 | Providing and fixing in position SWR UPVC specials for soil waste vent or anti syphonge pipes as per IS-14735 including cutting and wastage etc. cutting holes in walls roofs etc. and making good to its original condition but excluding cost of lead joining. B) or 110mm O/D pipe (V) P Trap/Floor Trap 110mm x 75mm.(CSR item No.30.81 (iii) B (X)). |
| 131 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) a) 110mm o/d. (CSR item No. 30.77 C (b) ). |
| 132 | Providing PVC solvent cement joints to SWR Pipes and specials including cost of PVC solvent cement and tools etc of approved make (to the approval of Engineer-in-charge ) (b) 90 mm o/d. (CSR item No. 30.77 C (c) ). |
| 133 | Providing and fixing in position SWR UPVC special for soil waste vent or anti siphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. For 110mm o/d pipes P Trap/Floor Trap 110mm x 75mm.(CSR item 30.81 iii (b) x ). |
| 134 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc. as per standard design minimum depth of water should be 150 mm with a minimum seal 50mm (b) 100mm internal Diametre H.C.I. gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg.and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm (CSR item No. 30.99 (b) ). |
| 135 | Providing, laying, jointing , fixing and testing ISI marked G.I. pipe (as per IS 1239) B-class premium make such (Jindal Hisar) including cost of specials (such as tees, bends, sockets, elbows etc.) painting with anti-corrosive bitumastic paint, testing, cutting, threading inside building complete. a) 15 mm i/d(CSR item No. 28.35(i)). |
| 136 | Providing, laying, jointing , fixing and testing ISI marked G.I. pipe (as per IS 1239) B-class premium make such (Jindal Hisar) including cost of specials (such as tees, bends, sockets, elbows etc.) painting with anti-corrosive bitumastic paint, testing, cutting, threading inside building complete.b) 20mm i/d(CSR item No.28.35(ii)). |
| 137 | Providing, fixing and jointing G.I. Union couplings (of approval make with the approval EIC) as per IS 1879 in G.I. pipe lines complete in all respect. 28.40 (A)a) 15 mm i/d G.I Union( CSR item No.28.40(A)) |
| 138 | Cutting chase in brick walls in cement or in floor for embedding G.I. or C.I. pipes line and making good the same to its original condition a) Size 75mmx75mm . (CSR item No. 30.85 (A) ) |
| 139 | Cutting holes upto 23 cm square through B.B. in cement walls or stone masonry wall in cement for pipes, and making good the same & finishing according to existing finish where required. (L/R) b) Through wall 22.86 cm thick 28.56 (b) |
| 140 | Providing and fixing in position M.S. or heavy flat iron clamps made out of M.S. flat iron not less than 5mm of the approved design for fixing C.I. soil waste, vent or antisyphonage pipes to walls complete in all respect. Including cutting and making good the walls and floors etc. and painting. (a) M.S. holder bats clamps for 100mm i/d H.C.I. pipes. (CSR item No.30.78 (a)) |
| 141 | Providing & Fixing in postion 15 mm i/d bib cock as per IS:210 with stainless steel spindle of approved make (to the approval of Engineer-in-charge) complete in all respect. (i) C.P. brass Bib cock long nose/ long body foam flow without flang (CSR item No.30.65 A (i)). |
| 142 | Providing and fixing in position stop cock/ Angle valve of approved make ( to the approval of Engineer-in-charge) complete in all respect. c) C.P. brass 15mm angle valve without flange (CSR item No.30.66 (c)). |
| 143 | Providing and fixing in position stop cock/ Angle valve of approved make ( to the approval of Engineer-in-charge) complete in all respect. b) C.P. brass 15mm Concealed stop cock with flange (CSR item No.30.66 ( b)). |
| 144 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P brass waste 32mm die with one C.P brass pillar tap including rack bolt screw pair 115mm long complete in all respect. ii) Size 550mmx400mmx815mm (CSR item No. 30.32 (ii) ). |
| 145 | Providing and fixing vitreous chinaware pedestal of approved make (to the approval of Engineer-in-charge) for wash hand basin complete in all respect.Vitreous chinaware standard white pedestal for wash hand basin.(CSR item No.30.43 (i)). |
| 146 | Providing and fixing PVC waste pipe 32mm complete in all respect.30.20 |
| 147 | Providing & fixing in position vitreous Chinware white Indian make flat back or angular lipped front small urinals size 265x315x440mm approved make (to the approval of the Engineer-in-charge) with C.P. brass tube connection 300 mm long complete in all respect. .(CSR item No.30.15). |
| 148 | Providing and fixing in position chinaware European type water closet with P trap or S trap size of approved make (to the approval of the Engineer-in-charge) consisting of 10 liters. PVC flushing cistern, PVC short bend 32mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge.(CSR30.4 A) |
| 149 | Providing and fixing in position Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity (without cistern fitting) with P trap or S trap of approved make (to the approval of the Engineer-in-charge) and seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. (a) Chinaware Floor Mounted One Piece EWC type with matching chinaware cistern 10 ltr. Capacity (Without cistern fitting) size 62x37x67 cm with P trap or S trap and seat cover complete in all respect. (CSR item No.30.3 (a)). |
| 150 | Providing and fixing stainless steel health faucet complete in all respect.( CSR item No.30.24). |
| 151 | Providing and fixing in position C.P. brass soap dish of approved make (to the approval of Engineer-in-charge) fixed into wall with rawl plugs and C.P. brass screws complete in all respect. (CSR item No. 30.60). |
| 152 | Providing and fixing in position 5mm thick beveled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backing fixed in with crawl plugs 50mm, C.P. brass screws and washer and S/S studs on top complete in all respect (as required by the Engineer-in-charge) (a) Size 600mmx450mm. (CSR item No.30.61 (A)). |
| 153 | Providing and fixing in position towel rail/ ring of approved make (to the approval of Engineer-in-charge) fixed in with crawl plugs embedded in walls with brass screws complete in all respect. (b) C.P. towel ring (CSR item No.30.58 (b)). |
| 154 | Providing and fixing in position PVC flexible tube connection of approved make ( to the approval of Engineer-in-charge) complete in all respect. (f) PVC tube connection of size 15 mm x 600 mm with C.P. Brass nut (CSR item No. 30.72(f)). |
| 155 | Providing and fixing in position S.S. grating with frame of approved make ( to the approval of Engineer-in-charge) complete in all respect.(CSR item No.30.80). |
| 156 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C.inspection chamber cover and frame (Weight as per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. a) Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal. ( CSR item No.29.60 (a)). |
| 157 | Making connection with the existing G.I. branch main up to 40 mm size pipe including cutting of existing pipe threading of pipe lines from both ends and fixing of G.I. etc. in the pipe line (including cost of G.I. Tee) complete in all respect.( CSR item No.28.45). |
| 158 | Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floor with cement concrete 1:2:4 mix (1 cement :2 concrete sand : 4 : graded stone aggregate 20mm nominal size) cement plastered on both side with cement mortar 1:2 (1cement : 2 coarse sand ) finished with a floating coat of neat cement and making necessary channals for the drain etc. complete. (a) For pipes 100 to 250mm Diameter (CSR item No.29.65 (a)). |
| 159 | Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge) fixed in to wall with C.P brass screws complete in all respect. a) C.P. brass toilet paper holder. (CSR item No. 30.57 (a)). |
| 160 | Providing, laying, jointing , fixing and testing ISI marked G.I. pipe (as per IS 1239) B-class premium make such (Jindal Hisar) including cost of specials (such as tees, bends, sockets, elbows etc.) painting with anti-corrosive bitumastic paint, testing, cutting, threading inside building complete. a) 20 mm i/d(CSR item No.28.35(ii)). |
| 161 | Providing and placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer-in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flow pipes but without fittings and base support for tank. i) Triple layer Tanks. (CSR item No. 30.97-A (i)). |
| 162 | Providing and fixing in position automatic brass ball cock in tanks. b) Brass Ball cock with rod and Plastic ball i) 20mm i/d { CSR Item no. 30.96 (b) (ii)). |
| 163 | Providing and placing in position G.I. Tank Nipple of approved make in PVC water storage tanks complete in all respect. a) G.I. tank nipple 20mm i/d { CSR Item no. 30.98 (b) }. |
| 164 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. pipe lines including all carriages complete. a) 20 mm i/d Brass Ball valves { CSR Item no. 28.44 (b) }. |
| 165 | Providing and fixing in position C.P. brass overhead shower 1 flow with shower arm with 15mm i/d inlet of approved make (to the approval of Engineer-in-charge) complete in all respect.(CSR item No.30.56 (a)). |
| 166 | Providing and fixing in position paper holders of approved make (to the approval of Engineer-in-charge ) fixed in to wall with C.P brass screws complete in all respect. C.P. brass toilet paper holder. (CSR item No.30.57 (a)). |
| 167 | Providing and fixing in position C.P. Acrylic shelf with C.P.bracket and guard rails of approved make (to the approval of Engineerin-charge ) fixed in with rawl plugs and C.P brass screws complete in all respect. CP brass Acrylic Shelf size 560mmx130mm CSR 30.59 (a) |
| 168 | Providing and fixing in position C.P. Acrylic shelf with C.P.bracket and guard rails of approved make (to the approval of Engineerin-charge ) fixed in with rawl plugs and C.P brass screws complete in all respect. C.P. brass Glass Corner with rail 8 mm thickness and height 250 mm (CSR item No. 30.59 (b)). |
| 169 | Providing ISI marked G.M. ferule as per IS: 2692 drilling and tapping cost iron pipe lines of all diameters and screwing in ferule and connections complete in all respect. (f) 25mm i/d Ferrule heavy duty(CSR item No. 28.34 (f)). |
| 170 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting,threading and testing in trenches in the ground complete. (f) 50mm (CSR item No.28.36 (f) ). |
| 171 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting,threading and testing in trenches in the ground complete. (c) 25mm (CSR item No.28.36 ( c )). |
| 172 | providing, fixing and jointing brass ball valves screwed with SS/ brass ball & spindle & Teflon seats, on GI pipe lines including all carriage complete. (a) 15mm i/d Brass Ball valves |
| 173 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect. F) 50mm i/d G.I union . (CSR item No.28.44(f)). |
| 174 | Excavation manually in trenches for pipe lines with straight or open cutting in streets and lanes in builtup area where width of street / Lane from wall to wall is less than 3 meter including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. Providing & fixing caution boards, watching, fencing, etc. and removal of surplus soil from the site upto 15 meter distance complete in all respects. (a) Earth work upto 1.5 m. Depth (i) All classes of soil except rocky.( CSR item No.28.2 (a) ii). |
| 175 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.(g) 65mm i/d (CSR item No.28.36 (g)). |
| 176 | Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) B-Class, including cost of Specials such as tees, bends, sockets elbow etc., cutting,threading and testing in trenches in the ground comple (f) 50mm i/d (CSR item No.28.36 (f)). |
| 177 | Providing ISI marked G.M. ferule as per IS: 2692 drilling and tapping cost iron pipe lines of all diameters and screwing in ferule and connections complete in all respect. (f) 25mm i/d Ferrule heavy duty ( CSR item No.28.34 (f)). |
| 178 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.f) 50mm i/d G.I. Union (CSR item No.28.40 (f)). |
| 179 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879 in G.I. Pipe lines complete in all respect.g) 65mm i/d G.I. Union (CSR item No.28.40 (g)). |
| 180 | Providing, fixing and jointing ISI Marked GunMetal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete (g) 65mm i/d Gun Metal peet valve heavy pattern. (CSR item No.28.43 (g)). |
| 181 | Providing, fixing and jointing ISI Marked GunMetal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete.(f) 50mm i/d Gun Metal peet valve heavy (CSR item No.28.43 (f)). |
| 182 | Providing and fixing in position Cast Iron Foot valves flanged ends with rubber sheat as per IS 4038 including cost of Nut Bolt , rubber insertion complete in all respect (a) 50mm i/d Cast Iron Foot valves (CSR item No. 28.131(a)). |
| 183 | Main hole Cover 3*3 (NS). |
| 184 | Cement concrete 1:6:12 (b) With stone aggregate 40mm gauge (ii) mixing by mechanical means using concrete mixer volumetric type( CSR item No.10.8 b ii)). |
| 185 | 12.5 mm thick cement plaster 1:3 (CSR item No.15.8) |
| 186 | Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixeras per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth.(CSR item No.10.15). |
| 187 | Cold twisted detormed (Ribbed/ Tor steel) Bars (Fe 500 grade as per IS 1786-2008) , for R.C.C works, where not including in the complete rate of RCC including bending and binding placing in position complete. (CSR item No.18.18). |
| 188 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering). (CSR item No.9.1). |
| 189 | Centering and shuttering for faces of walls, partitions, retaining walls and the like (vertical or battering including attached pilasters buttresses etc. (CSR item No.9.2). |
| 190 | Monoblock Pump 1 Hp.( NS). |
| 191 | Monoblock Pump 2 Hp.( NS). |
| 192 | Monoblock Pump 3 Hp.( NS). |
| 193 | PART-A ELECTRICAL Work For Waiting Room |
| 194 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm,1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required fosuitabl number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20 Amp. switches with indicator etc. and covered with Frame Plate etc., PVCconnector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four wayPVC1½\\"deep for walls and CI3\\"deep for ceiling),bonding to earth with PVC insulated copper conductor single core FR cable (ISImarked) 1sq.mm, 1100 volts grade (For 6 Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface) Wiring fan point (With fan box)( Waiting hall) ( CSR item No. 34.02( I) b ). |
| 195 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm,1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required fosuitabl number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20 Amp. switches with indicator etc. and covered with Frame Plate etc., PVCconnector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four wayPVC1½\\"deep for walls and CI3\\"deep for ceiling),bonding to earth with PVC insulated copper conductor single core FR cable (ISImarked) 1sq.mm, 1100 volts grade (For 6 Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface) Wiring light point.( CSR item No.34.02 (ii)). |
| 196 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm,1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required fosuitabl number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20 Amp. switches with indicator etc. and covered with Frame Plate etc., PVCconnector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four wayPVC1½\\"deep for walls and CI3\\"deep for ceiling),bonding to earth with PVC insulated copper conductor single core FR cable (ISImarked) 1sq.mm, 1100 volts grade (For 6 Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface) Wiring call-bell point ( CSR item No.34.02 (iii)). |
| 197 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm,1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required fosuitabl number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20 Amp. switches with indicator etc. and covered with Frame Plate etc., PVCconnector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four wayPVC1½\\"deep for walls and CI3\\"deep for ceiling),bonding to earth with PVC insulated copper conductor single core FR cable (ISImarked) 1sq.mm, 1100 volts grade (For 6 Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface) Wiring 6Amp. wall socket point ( CSR item No.34.02 (iv)). |
| 198 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm,1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required fosuitabl number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20 Amp. switches with indicator etc. and covered with Frame Plate etc., PVCconnector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four wayPVC1½\\"deep for walls and CI3\\"deep for ceiling),bonding to earth with PVC insulated copper conductor single core FR cable (ISImarked) 1sq.mm, 1100 volts grade (For 6 Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface) Wiring6Amp. Plugcontrol comprisingwall socket point ( CSR item No.34.02 (v)). |
| 199 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring inPVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm,1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required fosuitabl number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20 Amp. switches with indicator etc. and covered with Frame Plate etc., PVCconnector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four wayPVC1½\\"deep for walls and CI3\\"deep for ceiling),bonding to earth with PVC insulated copper conductor single core FR cable (ISImarked) 1sq.mm, 1100 volts grade (For 6 Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (with finishing the surface) Wiring 16/20Amp. power plug control point ( CSR item No.34.02 (vi)). |
| 200 | PVC INSULATED FR COPPERCONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge: (ii) overall 1.5 sq.mm, 1100volts grade { CSR Item no. 34.09 (ii) }. |
| 201 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copperconductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge: (iii)overall 2.5 sq.mm, 1100volts grade{ CSR Item no. 34.09 (iii) }. |
| 202 | PVC INSULATED FR COPPERCONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge: (iv)overall 4 sq.mm, 1100volts grade { CSR Item no. 34.09 (iv) }. |
| 203 | COPPER EARTHING: 8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First-class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:-(a) Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long. (CSR item No.34.14 (i)( a)). |
| 204 | SHEET METAL DOUBLE DOORDISTRIBUTION BOARD FOR MCB's/RCBO's/ RCCB's: Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers / RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-TP&N Horizontal Double Door Distribution Board 8 way each (CSR item no 34.17 vii)). |
| 205 | SHEET METAL IRON CLAD SWITCHES: Supply and erection of sheet metal iron clad switch on existing surface with G.I. bolts & nuts/ rag bolts and nuts etc., according to the size of holes in the body of the enclosure including connections with suitable size of thimbles and bonding to the existing earth as Per PWD General Specifications 2010. (vii) iron clad triple pole switch with neutral link 100amp. 415 volts { CSR Item no. 34.18 (vii) }. |
| 206 | MINIATURE CIRCUIT BREAKERS: Supply and erection of Miniature Circuit nBreaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as perPWD General Specifications including connections with suitable size of thimbles/lugs: (ii) MCB Single Pole 6-32amp. (10kA, Curve-C) { CSR Item no. 34.16 A (ii) } |
| 207 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES: Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and otherpetty materials etc., as per PWD General Specifications (vii) Medium Gauge PVC Conduit Pipe 25mm dia. (On Surface) { CSR Item no. 34.12 (vii) }. |
| 208 | Providing & Fixing Exaust Fan 10'' Heavy duty complete in all respect as per instructions/ Approval of the Engineer –in charge.( MR). |
| 209 | Providing & Fixing Exaust Fan 15'' Heavy duty complete in all respect as per instructions/ Approval of the Engineer –in charge. ( MR). |
| 210 | Providing & Fixing 1.8 tons Inverter Split Air Conditioners (4 star) complete in all respect as per instructions/Approval of the Engineer –in charge.( MR). |
| 211 | Providing & Fixing Stablizer for AC (120 v- 280 v) complete in all respect as per instructions /Approval of the Engineer –in charge. ( MR). |
| 212 | Providing and fixing 65\\" 4k-UHD display,350 nits brightness,smart TV, screen share/smart share, Wi-fi inbuilt, commercial TV features,anti-theft system, one chanel map,instant on,v-lan tag,external clock compatibility, world clock, alram, commercial swivel stand,welcome message/video,20 watt speakers, HDR-10, Signage Software Compatibility, Crestron & Beacon Connected, Self-Diagnostics, 3 Years On Site Warranty. Inputs/Outputs – HDMI-3, Audio in, USB -1, RJ 45 in -1, Component, Composite, Optical Audio, RS232C, CL Slot, RF in, complete in all respect as per instructions/ Approval of the Engineer –in charge. ( MR). |
| 213 | Providing and fixing Wall fan complete in all respect as per instructions/ Approval of the Engineer –in charge. ( MR). |
| 214 | PART-B (Fire Alarm System and Fire Extinguisher (Fire Alarm System required for Hospital (SITC) Raval Avani) |
| 215 | Fire panel (8 loops). ( MR). |
| 216 | Smoke Detectors. ( MR). |
| 217 | Manual Call Point. ( MR). |
| 218 | Hooters. ( MR). |
| 219 | Amplifier (8 Zones) AHUJA. ( MR). |
| 220 | Speakers . ( MR). |
| 221 | Cable 1.5 Sq mm 2 core (polycab). ( MR). |
| 222 | Fire e Extinguisher ABC (06 Kg) Stored pressure ( Flame End). ( MR). |
| 223 | Water Stored pressure (09 Ltr.). ( MR). |
| 224 | CO2 (4.5 Kg). ( MR). |
| 225 | PART-B Fire Hydrant System |
| 226 | MS Pipe 4\\" C class Install ( MR). |
| 227 | Hose Box Double Door ( MR). |
| 228 | Landing Valve SS Type ( MR). |
| 229 | Hose Reel Complete with Fittings ( MR). |
| 230 | Hose Pipe Polymer Type B 15 mtr ss type ( MR). |
| 231 | Branch Pipe multipurpose jet and spray heavy ( MR). |
| 232 | Two way S.S. Type ( MR). |
| 233 | Labour civil work ( MR). |
| 234 | PART-CElectrical Part: |
| 235 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. Combined/ universal Socket (shuttered) 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:-Wiring fan point (Without fan box).( as per CSR Item No. 34.02 (i) (a) ). |
| 236 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. Combined/ universal Socket (shuttered) 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:-Wiring light point. (as per CSR Item No. 34.02 (ii) ) |
| 237 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. Combined/ universal Socket (shuttered) 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:-Wiring 6Amp. wall socket point .(as per CSR Item No. 34.02 (iv)). |
| 238 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. Combined/ universal Socket (shuttered) 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:-Wiring 16/20Amp. power plug control point.[ as per CSR Item No. 34.02 (vi) (108 for A.C & 98 for Power)]. |
| 239 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. Combined/ universal Socket (shuttered) 6/10Amp. Switches and 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\\" deep for walls and CI 3\\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc. including the cost of above material, cutting and filling up of chases:-Wiring call-bell point .as per CSR Item No. 34.02 (iii) |
| 240 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm toIS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1sq.mm (Un-sheathed) as per CSR Item No. 34.09 (i) |
| 241 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm toIS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 1.5sq.mm (Un-sheathed) as per CSR Item No. 34.09 (ii) |
| 242 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm toIS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 2.5sq.mm (Un-sheathed) as per CSR Item No. 34.09 (iii) |
| 243 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm toIS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 4sq.mm (Un-sheathed) as per CSR Item No. 34.09 (iv) |
| 244 | PVC INSULATED FR COPPER CONDUCTOR CABLES: Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm toIS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Overall size 6sq.mm (Un-sheathed) as per CSR Item No. 34.09 (v) |
| 245 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminum conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1) 1988 to be laid (On Surface) as per PWD General Specifications:-Overall size 50sq.mm (3½ Core) Un-armoured (On-Surface) as per CSR Item No. 34.10 C (xxiv) |
| 246 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminum conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- (For Street light) Overall size 10sq.mm (4Core) Un-armoured (On-Surface) CSR item No. 34.10 C (xxxvi). |
| 247 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminum conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:- (For Street light) Overall size 25sq.mm (4Core) Un-armoured (On-Surface) CSR item No. 34.10 C (xxxviii) |
| 248 | OVER HEAD DISTRIBUTION ALUMINIUM CABLES, ACSR CONDUCTORS, CLAMPS, JUMPERS & JOINT KITS:Wiring over-head line in PVC insulated & PVC sheathed two single core aluminum conductor cable overall 1100 volts grade binding with G.I. wire 2mm dia. (14 SWG) with brass/ aluminum link clips complete in all respect as approved and desired by the Engineer In-Charge at site.PVC insulated & PVC sheathed aluminum conductor cable Overall Size 4mm² (1/1.40mm) Twin Core CSR item No. 34.34 (i) (a) |
| 249 | COPPER EARTHING: 8 SWG COPPER EARTHING : Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimble (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation:-Earthing with 8 SWG (4mm dia.) copper wire thimble with 30cm x 60cm x 2mm thick copper plate buried 4.50 metre (14.76 feet) below ground level (up to 8metre in Length) with G.I. pipe 20mm dia. (A-class), 3metre long as per CSR item No. 34.14 (i) (a). |
| 250 | Supply and erection of heavy duty Copper thimbles/lugs for cable end termination duly crimped including making necessary connections etc. completely:- Copper thimble cable Core size 10 - 16sq.mm as per CSR item No. 34.38 B (ii) |
| 251 | Supply and erection of heavy duty aluminum thimbles/lugs for cable end termination duly crimped including making necessary connections completely:-Aluminum thimble cable Core size 25-35sq.mm as per CSR item No. 34.38 A (iii) |
| 252 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-TP&N Horizontal Double Door Distribution Board 8 way Each as per CSR Item No. 34.17 (vii) |
| 253 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB's:Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB/ RCCB/ RCBO as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:- TP&N Horizontal Double Door Distribution Board 12way each as per CSR Item No. 34.17 (viii) |
| 254 | MCCB'S (FOR PANELS & SHEET ENCLOSURE):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (Conforms to IEC:60947-2) having Ics=100%, Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-MCCB Four Pole 40amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting as per CSR Item No. 34.23B (i) |
| 255 | MCCB'S (FOR PANELS & SHEET ENCLOSURE):Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (Conforms to IEC:60947-2) having Ics=100%, Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevant PWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc:-MCCB Four Pole 63/80/100amp., 415volts, ≥25kA Fixed Magnetic and Adjustable Thermal Setting as per CSR Item No. 34.23B (ii) |
| 256 | MINIATURE CIRCUIT BREAKERS/ RCBO's/ RCCB's:Supply and erection of Miniature Circuit Breaker MCB's for circuit protection against overload and short circuit current fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- MCB Single Pole 6-32amp. (10kA, Curve-C) as per CSR Item No. 34.16 A (ii) |
| 257 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, MS saddle clamps and other petty materials etc., as per PWD General Specifications:- Heavy Gauge PVC Conduit Pipe 40mm dia. (Flushed) as per CSR Item No. 34.12 (xii) |
| 258 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, MS saddle clamps and other petty materials etc., as per PWD General Specifications:- Heavy Gauge PVC Conduit Pipe 25mm dia. (Flushed) as per CSR Item No. 34.12 (x) |
| 259 | ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure):Supply and erection of On Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connection on both sides of switch with suitable size of thimbles as per PWD General Specifications:- On Load Change Over Switch Four Pole 200 amp., 415volts (With Sheet Enclosure) as per CSR Item No. 34.22 B (v) |
| 260 | Supply and erection of sheet metal double door Phase segregated distribution boards IP 43-IK09 metal door (dust protected) as per IS:8623-1&3,IEC61439-1&3 suitable for flush mounting with fully insulated copper busbars for each phase, 2Nos. shrouded neutral bars, 2Nos. earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label, compartmentalizing each phase (separated incomer, sub incomer & outgoing) and of required no. of ways for mounting FP MCB as incomer, DP/RCBO/RCCB's as sub incomer and SP MCB's as outgoings in the distribution board as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-TP&N Double Door Phase Segregated Distribution Board 8 way each CSR item No. 34.17 (xv) (c ) |
| 261 | LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilities for extensions or reduction as per the space or requirements). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacture should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick open able type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. Painting: - The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work. Busbars:-The panel shall be provided with TPN aluminum bus bar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminum (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contactor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site. Detail of capacities of MCCB's to be installed in the cubical panel Enclosure (Excluding the cost of MCCB's) as per following. (for ACs) LT Panel enclosure with having space for 1No. Incomer MCCB 250Amp. and 8 Nos. outgoing MCCB's 63amp. to 100amp. according to the requirement at site (Approx. size 1575 x 1700 x 400mm) CSR item No. 34.23 (A) (iv) |
| 262 | Power Generator DG Set 100 KVA (MR). |
| 263 | LT Panel enclosure with having space for 1No. Incomer TPN MCCB 63Amp. 8 Nos. outgoing 40 amp TPN MCCB. The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. complete in all respects.(MR). |
| 264 | LED Tube light 22 watt complete in all respect.(MR). |
| 265 | LED flood light 30 watt complete in all respect.(MR). |
| 266 | LED light 2’x2’ Ceiling Light 36/40 watt complete in all respect . (MR). |
| 267 | Providing wall fan 16”/400mm (MR). |
| 268 | ERECTION OF FANS: Erection of Ceiling/ Cabin/ Exhaust fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75sq.mm complete:- Erection of Exhaust fan with louver shutter on the wall/ window grill CSR item No. 34.28 (A) (i) (c ) |
| 269 | ERECTION OF FANS: Erection of Ceiling/ Cabin/ Exhaust fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75sq.mm complete:-Erection of Cabin fan on the w all CSR item No. 34.28 (A) (i) (b ) |
| 270 | ERECTION OF FANS: Erection of Ceiling/ Cabin/ Exhaust fan having connection with PVC insulated PVC sheathed two single core copper conductor (FR) cable 0.75sq.mm complete:- Erection of Ceiling fan CSR item No. 34.28 (A) (i) (a ) |
| 271 | Exhaust fan 15” heavy duty(MR). |
| 272 | Exhaust fan 12” heavy duty(MR). |
| 273 | Ceiling Fans with regulator (1400mm sweep) 5 star rating(MR). |
| 274 | HEAVY GAUGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan of length 1.5 to 2.0 mtr. long CSR item No. 34.11 (xi) |
| 275 | 4 MP CAMERA STQC CERTIFIED |
| 276 | CAT 6 |
| 277 | HDMI KVM CONVERTER |
| 278 | FIBER CABLE 6 CORE |
| 279 | HDD 4 TB |
| 280 | MEDIA CONVERTER |
| 281 | PVC BOXES |
| 282 | GIGA SWITCH 8 PORT |
| 283 | 4 U RACK |
| 284 | ACCESSORIES |
| 285 | INSTALLATION CHARGES |
| 286 | 6 U RACK |
| 287 | LED TV 4K 75” |
| 288 | 64 CHANNEL NVR |
| 289 | LT PANELS & MCCB's (MOULDED CASE CIRCUIT BREAKERS): Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilities for extensions or reduction as per the space or requirements). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacture should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55). Fabrication:- Panel shall be made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar channel as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus link should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/top with cable glands etc. Painting :- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company premises) after necessary putty work . Busbars:-The panel shall be provided with TPN aluminum busbar of suitable size according to the size of MCCB's. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminum (1A/Sq.mm). All Busbar will be air insulated with codified in Red, Yellow, Blue & Black as per standard for cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering :-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT's & L.E.D. type indicator etc. Manufacturer of Panel should be CPRI Approved (Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contactor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site. Detail of capacities of MCCB's to be installed in the cubical panel Enclosure (Including the cost of MCCB's) as per following requirement. In each panel (1 No. ACB of 800Amp as incomer, 4 No. MCCB’s of 315Amp. and 04 No. 250 Amp (Approx. size 2025 x 1800 x 400mm). |
| 290 | PART-CAIR CONDITIONER PART |
| 291 | Split AC 1.5 Ton, Hot & Cold, 3-Star |
| 292 | Stabilizer 4 KVA |
| 293 | High wall Split AC Stand |
| 294 | Installation Charges (AC) |
| 295 | Gas Pipe |
| 296 | PVC Drain Pipe for Indoor Unit (25mm2) |
| 297 | PVC Drain Pipe Union (25mm2) |
| 298 | PVC reducer Tee (25mm2) |
| 299 | Clamp for fixing PVC drain pipe (25mm2) |
| 300 | Installation Charges (PVC Pipe fixing) |
| 301 | PVC drain pipe socket (25mm2) |
| 302 | Petty items such as PVC elbow, PVC bond/Solution Gutties, screws etc. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 10, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 24, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 32 daysSep 25, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 33 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender