Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #56925599

Tender For Special Repair/ Replacement Of E/M Infrasructure At Rudraprayag And Gaucher Under Ge 871 Ews.

Issued by Statutory Bodies & Commissions/Committees · Rudra Prayag, Uttarakhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Aug 2026
20 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rudra Prayag → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Special Repair/ Replacement Of E/M Infrasructure At Rudraprayag And Gaucher Under Ge 871 Ews.

BOQ

Name of Work:- SPECIAL REPAIR/ REPLACEMENT OF E/M INFRASRUCTURE AT RUDRAPRAYAG AND GAUCHER UNDER GE 871 EWS.
Sl. No. Item Description
1SCHEDULE 'A' PART-I : BOQ OF WORKS FOR ELECTRIFICATION WORKS.
2Dismantling and setting aside of old electric poles for re-use use within 50 metres including transporting to store and stacking steel poles with struts, any size and any type, complete all as specified and as directed.
3Steel tubular swaged poles complete with mild steel base plate, finial taper plug, bolts, nuts and screws as specified, type-410, SP-31 (9.00 meters long), including painting with two coats of aluminium paint over one coat of zinc chrome primer after preparing the exposed surface and two coats of bitumiunous paint on embedded surfaces, including one No yellow strip and two Nos of black strip at 1.50 mts height from the grond level, fixing in repairs, complete all as specified and as directed.Note: Excavation, earth work and concrete in foundation shall be measured and paid separately under respective items of BOQ.
4Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed.Note: Punned thickness shall be measured.
5Double wall corrugated HDPE pipe, orange colour, ISI marked, nominal size 50 mm dia with 38 mm inner dia, conforming to IS: 16205 Part-24, including connecting accessories i.e couplers, connectors, bends, sockets, for protection of electric cable, laying in trenches, duct or fixed to walls/ poles as required, complete all as specified and as directed.Make: Prince/ Finolex/ Astral/ RC Plasto/ Supreme.
6Sub class ‘B’ bricks, modular size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning for mechanical protection of cable, with width equal to the length of the brick, complete all as specified and directed.
7Plain cement concrete M-10(1:3:6), type C-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation, or in foundation of poles and stays, complete all as specified and as directed.
8Plain cement concrete M-10(1:4:8), type D-2 (using 40mm graded crushed stone aggregate), as mass concrete in foundation or in padding, or in foundation of poles and stays, complete all as specified and as directed.
9Plain cement concrete M-15 (1:2:4), type B-1 (using 20mm graded crushed stone aggregate), as in coping of pole's foundation including necessary form work, finish even and smooth without using extra cement, complete all as specified and as directed.
10Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 120 Sqmm, 3.50-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed.
11Description all as per serial item No- 1.09 here-in-before but for cable of size 95.0 Sqmm, 3.50 core
12Description all as per serial item No- 1.09 here-in-before but for cable of size 70.0 Sqmm, 3.50 core
13Description all as per serial item No- 1.09 here-in-before but for cable of size 50.0 Sqmm, 3.50 core
14Description all as per serial item No- 1.09 here-in-before but for cable of size 35.0 Sqmm, 3.50 core
15Replacement of old unserviceable/ damaged LT XLPE cable with new XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 25.0 Sqmm, 4.0-core, laid in trenches or passing through pipes, including suitable lugs and accessories for making connections at both ends, complete all as specified and as directed.
16Description all as per serial item No- 1.14 here-in-before but for cable of size 16.0 Sqmm, 4.0 core
17Description all as per serial item No- 1.14 here-in-before but for cable of size 10.0 Sqmm, 4.0 core
18Replacement of old unserviceable/ damaged MCCB with new MCCB, three pole, 415 Volts, adjustable thermal and fixed magnetic setting, 63 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu as per IEC 60947-2, complete all as specified and as directed.Make: Legrand cat part No- 4200 03 equivalent in L&T/ Schneider/ Merlin Gerin/ Siemens/ ABB.
19Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 100 Amps with breaking capacity 16 KA, having indicating lamp, Ics=100% Icu as per IEC 60947-2, complete all as specified and as directed.Make: Legrand cat part No- 4200 15 equivalent in L&T/ Schneider/ Merlin Gerin/ Siemens/ ABB.
20Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 160 Amps with breaking capacity 25 KA, having indicating lamp, Ics=100% Icu as per IEC 60947-2, complete all as specified and as directed.Make: Legrand cat part No- 4200 57 equivalent in L&T/ Schneider/ Merlin Gerin/ Siemens/ ABB.
21Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 250 Amps with breaking capacity 25 KA, having indicating lamp, Ics=100% Icu as per IEC 60947-2, complete all as specified and as directed.Make: Legrand cat part No- 4202 19 equivalent in L&T/ Schneider/ Merlin Gerin/ Siemens/ ABB.
22Replacement of old unserviceable/ damaged MCCB with new MCCB, four pole, 415 Volts, adjustable thermal and fixed magnetic setting, 400 Amps with breaking capacity 36 KA, having indicating lamp, Ics=100% Icu as per IEC 60947-2, complete all as specified and as directed.Make: Legrand cat part No- 4202 19 equivalent in L&T/ Schneider/ Merlin Gerin/ Siemens/ ABB.
23Dismantling and setting aside of old unserviceable LT Panels, any size and any type with complete fittings and accessories, complete all as specified and as directed.
24Supply installation, commissioning, new LT feeder pillar box/ panel, in-replacement of old unserviceable LT panel/ feeder pillar box, complete all as specified and as directed by Engineer-In-Charge.Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 26 of tender (CA) here-in-after.
25Supply installation, commissioning, new LT feeder pillar box/ panel, in-replacement of old unserviceable LT panel/ feeder pillar box, complete all as specified and as directed by Engineer-In-Charge.Note: Detailed description and accessories/ equipments shall be as mentioned on serial page No- 27 of tender (CA) here-in-after.
26Factory made junction box, made with thermo polycarbonate, weather, water and vermin proof, dust proof, for outdoor use, having internal dimensions 350mmx250mmx100mm, suitable for road/ street lighting for 3-phase/ 4-core high wattage LED based lighting system for industrial applications, suitable for pole mounting, including 01 No. MCB single pole, 6 Amps and 03 Nos. aluminium bus bars of 100 Amps rating duly drilled holes for connections, cable glands, clamps etc for making necessary connections along with locking arrangement, including mild steel iron flat size 25x4mm having holes, nuts, bolts, washers, for fixing/ mounting on poles, painted with two coats of synthetic enamel paint over one coat of primer on internal and external surfaces, fixing in repairs, complete all as specified and directed.
27Replacement of old unserviceable street light of any type and any description with new LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having top opening seperate driver compartment with IP66 protection, including LED lamps of 60 Watt and connecting up with three corePVC insulated, PVC sheated copper conductor cable of 1.50 Sqmm size, complete all as specified.Make: Havells cat part No-ENDURASUNBEAMSL60WLED757SASYTOPCSENSO/ Crompton cat part- Philips cat part No- BRP381 LED78/NW 60W 220-240V DWP P7 HP or equivalent in Crompton/ Bajaj.
28Disconnecting electric connections of servo voltage stabilizers, capacity 200 KVA, three phase, air cooled, designed for input voltage variations between 340 Volts to 460 Volts without voltage stabilized at 415 Volts wit accuracy of ±1% and transporting to workshop for repairs and return back to its original position after repairs by strip opening/ de-assembling for repair/ maintenance including loading and unloading by mechanical means and testing after repairs, complete all as specified and as directed. Note: Details of spares required for repair/ replacement of unserviceable parts are as under:(a) IC based electronic board suitable for existing 200 KVA Voltage stabilizer.(b) Servo Motor of existing specifications.(c) Trigger/ central transformer of existing specifications.(d) Micro switch of existing capacity and specifications.(e) RC filters of existing specifications.(f) Ammeter and Voltmeter of existing specifications and existing range.(g) Replacement of unserviceable/ damaged copper windings.
29Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron strip, size 32x6mm as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed.Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces. Please Enable Macros to View BoQ information
30Earthing complete with galvanised iron earth plate electrode 600x600x6mm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected with galvanised iron strip, size 32x6mm as earth lead, by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete with 40mm dia GI light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 in pit with precast RCC M-15(1:2:4), type B-1 (using 20mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc. all as shown in electric plate No-3 of SSR Part-I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50mtr, including testing on completion, complete all as specified and as directed.Note: Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surfaces. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56925599
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 31-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Special Repair/ Replacement Of E/M Infrasructure At Rudraprayag And Gaucher Under Ge 871 Ews.
Basic Detail
Tender No 8148/E8
Bidding Type Tender
Location
City Rudra Prayag
State Uttarakhand
Key Dates
Publish Date 10 Aug 2026
Submission Date 31 Aug 2026
Open Date 07 Sep 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 70000
Exemption Available
Document List
2e5c6836-dcc6-4eb1-99e4-8253d77815a9.html
BOQ_877957.xls
E-Tender.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Sep 07, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 27 days

Tender Documents

Download All (ZIP) ↓
html

2e5c6836-dcc6-4eb1-99e4-8253d77815a9.html

xls

BOQ_877957.xls

pdf

E-Tender.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders