Tender For Repair And Maintenance Of Various Type Of Link Sign Boards In Technical Area At Afs Bareilly Under Ge (Af) Bareilly
Tender Overview
Project Description
Tender for Repair And Maintenance Of Various Type Of Link Sign Boards In Technical Area At Afs Bareilly Under Ge (Af) Bareilly
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 14-Aug-2026 | CorrigendumNo.01 | BOQ | 31-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking out old existing LT under ground cable of size 10 Sqmm to 25 Sqmm 3.5 / 4 core including taking out old protection bricks from trenches, ducts, passing through pipe / fixing on poles etc all as specifed. |
| 2 | Supply, laying and testing for LT XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 4 core laid in trenches, ducts, passing through pipe / fixing on poles etc all as specifed. |
| 3 | All as per Item No.2.00 here-in-before but cable of size 16 Sqmm 4 core. |
| 4 | All as per Item No.2.00 here-in-before but cable of size 25 Sqmm 4 core. |
| 5 | Relaying of old serviceable LT XLPE under ground cable 1100 volt grade of size 3.5 / 4 core of size 10 Sqmm to 25 Sqmm after fault rectification complete all as specified and directed. [Note: Old serviceable cable retreived from item No. 1.00 of BOQ shall be re-used. Excavation & earth work will be measured and paid separately]. |
| 6 | M&L for straight through joint with heat shrinkable kit including ferrules and other jointing materials for LT XLPE / PVC insulated cable of size 3.5 / 4 core size 25 Sqmm to 35 Sqmm 1100 volt grade including testing the cable joint complete all as specified and directed. |
| 7 | M&L for horizontal boring under hard standing/ pavements or roads manually using suitable auger for insertion of pipes up to 80 mm bore including HDPE pipe 80 mm bore and making good the disturbed surface complete all as specified. |
| 8 | Excavation in trenches (manually) not exc. 1.50 mtr wide and not exc 1.50 mtr in depth for laying cables, foundation of electric pole, stay assembly etc and getting out in soft / loose soil all as specified. |
| 9 | M&L for laying of course sand, free from sharp materials as in filling in trenches for cable protection, laid to a uniform thickness of 23 cm (15 cm under the cable and 8 cm over the cable) and gently punned down to 18 cm thickness as required all as specified.Note: Punned down thickness (18 mm) shall be measured for payment purpose. |
| 10 | M&L for laying bricks for protection covers over cables using well burnt Sub class 'B' bricks of old size in trenches over sand cushioning all as specified. |
| 11 | All as per Item No.10.00 here-in-before but except bricks. [Note: Serviceable bricks retrieved from taking out cable from item No.1 above shall be re-used]. |
| 12 | Returning, filling in including spreading leveling watering and well ramming in layers not exc 25 cm in any type of soil all as specified. |
| 13 | Removing excavated materials to a distance not exc 50 mtr and depositing where directed at a level not exc 1.50 mtr above the starting point all as specified. |
| 14 | M&L for replacement of existing damaged/ broken/ unserviceable link sign board of overall size 1840 mm x 840 mm made of hard plastic or Perspex sheet duly framed with anodized aluminium strip of suitable size. The link sign board shall be mounted on 2 to 3 legs made of specialized frangible material. One alphabet / numeric letter like 'A' & 'E ' and the like of size 780 mm x 840 mm shall be written on both side of the board in yellow colour on black back ground and remaining portion of link sign board size 1060 mm x 840 mm shall be written on both side of board in white colur numerical i.e. 11 & 29 on Red back ground and black strip as per existing pattern. The link sign board shall have suitable number of LED lights with accessories such as LED driver, adopter, plate, rectifier to convert AC supply into DC supply etc. Link sign board shall be pre-wired with complete housing in the board including necessary PCC 1:2:4 type B-1 in foundation for fixing link board and making all electric connections as per existing sample at site as per requirement complete all as specified and directed. |
| 15 | M&L for replacement of existing damaged/ broken/ unserviceable link sign board of overall size 2360 mm x 840 mm made of hard plastic or Perspex sheet duly framed with anodized aluminium strip of suitable size. The link sign board shall be mounted on 2 to 3 legs made of specialized frangible material. One alphabet letter like 'A', & 'E' and the like of size 790 mmx 840 mm shall be written on both side of the board in yellow colour on black background and remaining portion of link sign board size 1570 mm x 840 mm shall be black and doted in two lines i.e 02 continous line and 02 doted lines written on both side of board in yellow back ground and black strip as per existing pattern. The link sign board shall have suitable number of LED lights with accessories such as LED driver, adopter, plate, rectifier to convert AC supply into DC supply etc. Link sign board shall be pre-wired with complete housing in the board including necessary PCC 1:2:4 type B-1 in foundation for fixing link board and making all electric connections as per existing sample at site as per requirement complete all as specified and directed. |
| 16 | M&L for replacement of existing damaged/ broken/ unserviceable link sign board of overall size 2340 mm x 840 mm made of hard plastic or Perspex sheet duly framed with anodized aluminium strip of suitable size. The link sign board is mounted on 2 to 3 legs made of specialized frangible material. One alphabet letter like 'B', 'C' , 'D' 'N' & 'M' and the like of size 690 mm x 840mm shall be written on both side of the board in yellow colour on black background and remaining portion of link sign board size 1650 mm x 840 mm shall be written on both side of board in white colur numerical i.e. 11-29 on Red back ground and black strip as per existing pattern. The link sign board shall have suitable LED lights with accessories such as LED driver, adopter, plate, rectifier to convert AC supply into DC supply etc. B27Link sign board shall be pre-wired with complete housing in the board including necessary PCC 1:2:4 type B-1 in foundation for fixing link board and making all electric connections as per existing sample at site as per requirement complete all as specified and directed. |
| 17 | M&L for replacement of existing damaged/ broken/ unserviceable link sign board of overall size 2360 mm x 840 mm made of hard plastic or Perspex sheet duly framed with anodized aluminium strip of suitable size. The link sign board shall be mounted on 2 to 3 legs made of specialized frangible material. One alphabet letter like 'B', 'C' , 'D' 'N' & 'M' and the like of size 770 mm x 840 mm shall be written on both side of the board in yellow colour on black back ground and remaining portion of link sign board size 1590 mm x 840 mm shall be black and doted in two lines i.e 02 continous line and 02 doted lines written on both side of board in yellow back gr+B32ound and black strip as per existing pattern. The link sign board shall have suitable number of LED lights with accessories such as LED driver, adopter, plate, rectifier to convert AC supply into DC supply etc. Link sign board shall be pre-wired with complete housing in the board including necessary PCC 1:2:4 type B-1 in foundation for fixing link board and making all electric connections as per existing sample at site as per requirement complete all as specified and directed. |
| 18 | M&L for repair to damaged / broken / unserviceable existig link sign board of overall size 2740 mm x 840 mm made of hard plastic or perspex sheet duly framed with anodised aluminium strip of suitable size. The link sign board shall be mounted on 2 to 3 legs made of specialized frangible material. One aphabet / numerical letter like '29 CAT-II' of size 2740 mm x 840 mm shall be written on one side of the board in white colour on Red back ground and black strip as per existing pattern. The link sign board shall have suitable number of LED lights with LED accessories such as LED driver, adopter, plate, rectifier to convert AC Supply into DC Supply etc. Link sign board shall be made pre-wired as in replacement of old burnt wires with complete housing in the board including suitable repair to the PCC 1:2:4 type B-1 in foundation for fixing link board and making all electric connections all as per existing sample at site with and including replacement of damages / broken mirror image complete all as per site requirement all as specified and directed. |
| 19 | M&L for replacement of existing damaged / broken / unserviceable link sign board of overall size 870 mm x 830 mm made of hard plastic or Perspex sheet duly framed with anodized aluminium strip of suitable size. The link sign board is mounted on 2 to 3 legs made of specialized frangible material. One alphabet letter like 'F','G' 'H' 'J' 'K' 'L' & 'Q' of size 670 mm x 830 mm shall be written on both side of the board in yellow colour on black back ground and black strip as per existing pattern. The link sign board shall have suitable number of LED lights with accessories such as LED driver, adopter, plate, rectifier to convert AC supply into DC supply etc. Link sign board shall be pre-wired as in replacement of old burnt wires with complete housing in the board including necessary repairs to PCC 1:2:4 type B-1 in foundation for fixing link board and making all electric connections as per existing sample at site with and including replacement of damages/ broken mirror image all as per site requirement all as specified and directed. |
| 20 | M&L for replacement of existing damaged/ broken/ unserviceable Airfield elevation sign board (ATC Tower) of overall size 3000mmx900mm, made of hard plastic or Perspex sheet duly framed with anodized aluminium strip of suitable size. One numerical / alphabet letter like '29- BAREILLY 51FT / 174M -11 of size 3000mmx900mm shall be written on one side of the board in black colour on yellow background and black strip as per existing pattern. The link sign board shall have suitable number of LED lights with accessories such as LED driver, adopter, plate, rectifier to convert AC supply into DC supply etc. B33 |
| 21 | M&L for replacement of existing damaged / broken / unserviceable sign board of size 800 mm x 450 mm, made of hard plastic or Perspex sheet duly framed with anodized aluminium strip of suitable size. One alphabet letter like 'C' of size 800 mm x 450 mm shall be written on one side of the board in black colour on yellow back ground and black strip as per existing pattern. The link sign board shall have suitable number of LED lights with accessories such as LED driver, adopter, plate, rectifier to convert AC supply into DC supply etc. Link sign board shall be pre-wired with complete housing in the board including all electric connections as per existing sample at site as per requirement complete all as specified and directed. |
| 22 | M&L for replacement of existing damaged/ broken/ unserviceable link sign board of overall size 3230 mm x 450 mm made of hard plastic or Perspex sheet duly framed with anodized aluminium strip of suitable size. The link sign board shall be mounted on 2 to 3 legs made of specialized frangible material. One alphabet / numeric letter like 'MAX SPAN 30M' and the like of size 3230 mm x 450 mm shall be written on both side of the board in black colour on yellow back ground and black strip as per existing pattern. The link sign board shall have suitable number of LED lights with accessories such as LED driver, adopter, plate, rectifier to convert AC supply into DC supply etc. Link sign board shall be pre-wired with complete housing in the board including necessary PCC 1:2:4 type B-1 in foundation for fixing link board and making all electric connections as per existing sample at site as per requirement complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender