Tender For Provn Of Additional Security Lights, Replacement Of Defective Street Light Poles And special Repair/ Replacement Of Lt Distribution System At Kv No 01 Chandimandir Mil Stn
Tender Value
19.06 Lakhs
Estimated cost
Bid Submission
31 Aug 2026
7 days left
EMD
38200
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Panchkula → Haryana
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provn Of Additional Security Lights, Replacement Of Defective Street Light Poles And special Repair/ Replacement Of Lt Distribution System At Kv No 01 Chandimandir Mil Stn
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches for foundations of poles, stays or for laying of cables, or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 1.5 mtr in depth and not exceeding 1.5 mtr in width and getting out in any type of soil complete all as specified and as directed.Note (Item No 01 & 02):- (i) Nothing extra will be paid or measured to the contractor if hard or rocky soil is encountered during execution. |
| 2 | Excavation in trenches for foundations, laying / taking out of cables, erecting of poles etc, in any type of soil, exceeding 1.5 mtr but not exceeding 3.0 mtr in depth and not exceeding 1.5 mtr in width and getting out, complete all as specified and as directed. |
| 3 | Returning, filling in soils, in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed. |
| 4 | Removing excavated soils to a distance not exceeding 50 metres and depositing where directed at a level not exceeding 1.50 metre above the starting point complete all as specified and as directed. |
| 5 | Supply and laying 50mm outer dia, inner dia 38mm, double walled, corrugated HDPE duct pipe conforming to IS- 14930 Pt-II with antirodent and non flame propogating properties of approved colour complete with fittings for cable protection complete all as specified and as directed. |
| 6 | Taking down old unserviceable electric cable as per existing and type including removing from site of work complete all as directed. |
| 7 | S & F Power Cables, Aluminium Stranded Conductor 16 sqmm, 4 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / Street light panel/ Junction box and testing on completion complete all as specified and directed by Engineer-in-Charge. |
| 8 | S & F multi stranded copper cable PVC insulated unsheathed 1100 volts grade of size 2.50 sqmm 3.00 core for connection from junction box to light fitting and making connections and testing for functioning of light fitting complete all as directed |
| 9 | S & F LED street light fitting 90 Watt, 230 V AC, min 120 lumens/watt outdoor type with high pressure die, cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including taking down old damaged unsv CFL/ T-5/ HPSV lights of any size/ type and removing from site, complete all as specified. |
| 10 | S & F post top lantern, LED type, 40 watt (cool white), 230 volts, AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed. |
| 11 | S & F LED flood light, 120 watt, 230 V, AC outdoor type, having efficiency of minimum 120 lumens/watt with thermal management in multiple optics and equipped with IP66 protection with impact and corrosion resistant, complete with driver, lamp as required at site all as specified and as directed. |
| 12 | S&F flood light mounting bracket fabricated from 50mm dia GI pipe medium grade, min 600mm long suitable for mounting two flood lights including all necessary clamps, nut, bolt and washers all as specified and as directed. |
| 13 | Taking down old unserviceable street light poles of any size and type including removing from site of work complete all as directed. |
| 14 | Supply, erection and fixing in position 9.00 metre long, steel tubular swaged poles complete with mild steel base plate, flat top welded type 410, SP-31 IS:2713 marked, drilling of necessary holes including bolts, nuts and washers as required and painting with two coats of Aluminium paint over a coat of red oxide primer on exposed, surfaces of poles and two coats of black bituminous paint throughout internally and externally upto the planting depth including providing reflective strips of width 10cm upto a height of 1.20m from ground level in alternate colour yellow and black around the pole of pattern as approved by GE and marking pole number at appropriate height with shade and colour as approved by Engineer-in-Charge complete all as specified and as directed. Note : Excavation earthwork and concrete work shall be measured and paid for separately. |
| 15 | S & F as in replacement mounting bracket suitable for street light LED fittings of length 1.50m, made out of light grade GI pipe of 50mm bore, bent to shape (120 degree ) as directed by Engineer-in-Charge complete with 02 x GI clamp made to shape out of 50mm X 6mm flat iron with nuts, bolts and washers of suitable size for fixing on pole/ wall, fixed to pole/ wall complete all as specified and directed. |
| 16 | S & F SMC (Sheet Moulded Compound) outdoor type junction box of size 200mm x 140mm x 95mm (outside dimensions) with 63Amps rated four pole connector, one single pole MCB of 6 Amps rating mounted on DIN rail, stainless steel cable glands of suitable size for incoming and outgoing cables including fixing on steel tubular poles/ PCC poles with 25mm x 4mm MS clamps (02 Nos), nuts & bolts etc complete all as specified and as directed. |
| 17 | M&L Cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation, filling and mass concrete and sub base all as specified and directed by Engineer - in - Charge |
| 18 | M&L Cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregate for foundations, fillings and mass concrete all as specified and directed by Engineer – in - Charge. |
| 19 | M & L cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in lintels up to 1.5 m clear span, seismic and other similar bands, benching, coping, bed blocks, apex stones and kerbs etc including use of necessary form work all as specified and directed by Engineer - in - Charge .Note: Nothing extra will be paid or measured to the contractor for removing/refixing of Junction Box etc with the pole if any during the copping/muffing execution at site . |
| 20 | M& L for earthing complete, testing, installation with galvanized steel plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level), with top edge of the plate not less than 1.50m below ground level, connected with and including GI /Steel 32 mm x 6mm earth lead strip by means of bolts, nuts, check nuts & washers of galvanized iron/ steel complete all as shown in electrical plate No 5 of MES Schedule Part-I and connected to earthing test point all as specified or indicated and testing on completion as directed by Engineer-in-Charge including excavation and earth work in any type of soil, funnel, plain cement concrete (1:3:6) type C-1 chamber, precast reinforced cement concrete (1:2:4) type B-1 pit cover 50mm thick of appropriate size with and including steel reinforcement, charcoal, common salt including protection of earthing strip by and including 40mm bore galvanized steel tubing, medium grade and 20mm bore galvanized steel tubing, medium grade pipe for watering complete all as specified as shown on drg /plates as indicated and as directed. |
| 21 | Notes:- (a) RCC pit cover shall be precast with cement concrete 1:2:4 type B1 reinforced with 8mm dia TMT steel bars @ 100mm c/c bothways. (b) Earth lead 32mm x 6m of galvanised iron / steel protected with 40mm bore GI pipe shall be provided upto a length of 7.50 metre. |
| 22 | Supply & fixing of nature switch smart timer based automatic street light control panel. The Panel should be suitable enough to take three phase load of 8 kW. Nature Switch Smart Timer should be maintenance-free in design and settings accessible via a Mobile App (with Bluetooth connectivity). The Mobile App should allow users to customize the ON & OFF timings based on natural light (sensor), local sunset/ sunrise (Astro) and Time. The Mobile App should also have facility to set Input Voltage range. The Smart Timer along with power contactor(s) and incoming-outgoing MCBs should be enclosed in a pole/ wall mountable rust proof, electric shock proof, termite proof and FR grade thermoplastic polycarbonate enclosure (with HINGED LID) conforming to IP-66 protection class 2. |
| 23 | Enclosure Should have following features:(i) Ingress Protection-IP66 (Dust & Powerful jet water proof) as per IEC 60529 (ii) Burning Behavior- Glow Wire test at 960 oC as per IEC 60695-2-11, Self Extinguishing & Flame Retardant (iii) Toxic Behavior – Silicone Free, Halogen Free, Corrosiveness of Fumes as per IEC 60754-2.(iv) Locking Arrangement: Transparent Lid is fitted with half-turn spring return fasteners for easy operation (v) Material: Thermoplastic Polycarbonate, Durable for decades |
| 24 | The circuit should also have provision for manual operation (i.e. Sensor By-Pass option)Make of switchgear & control gear: ABB/ Schnieder/ L&T/ Siemens/ C&S/ Legrand/ Havells.The Panel shall be comprising of following:(a) Incoming: (i) MCB TPN 32A 'C' Curve: 01 No(ii) Single pole contactor 25A: 03 Nos(b) Outgoing:(i) MCB SP 32 A 'C' Curve: 03 Nos.(ii) Nature switch: A Sensor for automatic switching of street light based on LUX level of natural light with bypass and time adjustment arrangement: 01 No(iii) Selector switch: 01 No(iv) Earthing terminals: 02 Nos(v) Circuit wiring of Copper wire minimum 10 Sqmm. |
| 25 | Supply and laying un-reinforced precast concrete cable cover, Class LV, type-I, flat size 250 x 150 x 40 mm complete all as specified and directed. |
| 26 | M & L for sand cushioning for protection of cable (below, above and around the cable laid in trenches) all as specified and as directed. |
| 27 | S & F as in replacement Power Cables, Aluminium Stranded Conductor 185 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V Grade as per IS 7098 (Part 1) complete laid in trenches / floors / ducts/ fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / Street light panel/ Junction box and testing on completion complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply, installation, testing and commissioning as in replacement of out door type LT feeder pillar box factory made CPRI approved; openable from front & rear, double door with flush type hinges and flush cylindrical locks, dust and vermin proof, fabricated 3.15 mm thick CRCA sheet duly painted with two coats of powder coated of approved shade over a coat of Zinc chrome primer and MC-75 channel for base frame work complete with 04 Nos heat shrinkable insulated Aluminium bus bars of capacity not less than 1.5 times of incoming MCCB/ACB including all MCCB connections with suitable rating Aluminum bus bar strip. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with danger notice plate with skull & bone sign, making all electrical incoming and out going electrical cable connection with new lugs, glands to be provided at cable entries, including 04 No. legs of not less than 75 cm long each below the base of panel made of angle iron support 50 x 50 x 6mm for grouting purpose and grouted in PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) complete all as specified and as directed and comprising of following accessories:- |
| 29 | INCOMING:(a) MCCB four pole 415 Volts ,50 HZ, 250Amps microprocessor based with LIG & LSIG protection and fault indication breaking capacity 36 KA with Ics = 100% Icu - 01 No Make: ABB/ Schnieder/ L&T/ Siemens/ C&S/ Legrand/ Havells. OUTGOING:(a) MCCB four pole 415 Volts, 50 HZ, 100Amps microprocessor based with LIG & LSIG protection and fault indication breaking capacity 25 KA with Ics = 100% Icu - 04 Nos . Make : ABB/ Schnieder/ L&T/ Siemens/ C&S/ Legrand/ Havells. (b) Phase indicator lamp complete with copper control wiring and suiable size of CT complete -01 (Set of three)(c) Digital type multi meter LCD display complete for voltmeter and ammeter of size 96 x 96 mm complete all as specified and directed. Note:-(i) All the switchgear used in the panel will be of same make.(ii) Drawing for LT Panel shall be approved by GE before placement of order by contactor. |
| 30 | Design, fabrication, supply, installation and testing as in replacement of outdoor type cubicle panel board bus bar box with MCCB suitable for 3 phase 4 wire, 50 Hz supply system factory fabricated made out of CRCA sheet steel of 3mm thick for outer shell and 2mm thick for inner shell with front openable door with locking arrangement complete with powder coat painting and suitable packing material for IP-54 degree of protection and including provision of 40 x 40 x 5mm angle iron base frame of suitable size for mounting the panel board at a height of 450mm above GL and grouted in PCC foundation. The size of panel board shall not be less than 500mm x 500mm x 300mm (outer dimensions) for accommodating provision of following switchgears complete:- |
| 31 | (i) TPN Aluminium bus bar 300 Amps 4 strips provided with heat shrinkable coloured PVC sleeve insulation mounted on insulators suitable for connecting 2 or 3 outgoing cables including provision suitable glands.(ii) MCCB, 200 A, 4 Pole, 36 KA (Ics=100%Icu), 415 V, 50 Hz, Microprocessor based - 01 No Make : ABB/ Schnieder/ L&T/ Siemens/ C&S/ Legrand/ Havells.Note:-(a) All the switchgear used in the panel will be of same make.(b) Drawing for LT Panel shall be approved by GE before placement of order by contactor. |
| 32 | M&L as in repairs for earthing complete, testing, installation with galvanized steel plate electrode 600mm x 600mm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level), with top edge of the plate not less than 1.50m below ground level, connected with and including GI /Steel 32 mm x 6mm earth lead strip by means of bolts, nuts, check nuts & washers of galvanized iron/ steel complete all as shown in electrical plate No 5 of MES Schedule Part-I and connected to earthing test point all as specified or indicated and testing on completion as directed by Engineer-in-Charge including excavation and earth work in any type of soil, funnel, plain cement concrete (1:3:6) type C-1 chamber, precast reinforced cement concrete (1:2:4) type B-1 pit cover 50mm thick of appropriate size with and including steel reinforcement, charcoal, common salt including protection of earthing strip by and including 40mm bore galvanized steel tubing, medium grade and 20mm bore galvanized steel tubing, medium grade pipe for watering complete all as specified as shown on drg /plates as indicated and as directed. |
| 33 | Notes:- (a) RCC pit cover shall be precast with cement concrete 1:2:4 type B1 reinforced with 8mm dia TMT steel bars @ 100mm c/c bothways. (b) Earth lead 32mm x 6m of galvanised iron / steel protected with 40mm bore GI pipe shall be provided upto a length of 7.50 metre. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 7 daysSep 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender