Defence Statutory Bodies & Commissions/Committees Closing in 13 days TDR #56925527

Tender For special Repair To Community Hall At Strand Line Area And special Repair To Bldg No S-42A (Cook House Store) Of 225 Coy Asc (Sup) Under Ge (C) Kolkata

Issued by Statutory Bodies & Commissions/Committees · Kolkata, West Bengal
Tender Value
30.89 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
13 days left
EMD
61798
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for special Repair To Community Hall At Strand Line Area And special Repair To Bldg No S-42A (Cook House Store) Of 225 Coy Asc (Sup) Under Ge (C) Kolkata

BOQ

Name of Work:- SPL REPAIR TO COMMUNITY HALL AT STRAND LINE AREA AND SPL REPAIR TO BLDG NO S-42A (COOK HOUSE STORE) OF 225 COY ASC (SUP) UNDER GE (C) KOLKATA
Sl. No. Item Description
1Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE ( C ) KOLKATA Name of Work: SPL REPAIR TO COMMUNITY HALL AT STRAND LINE AREA AND SPL REPAIR TO BLDG NO S-42A (COOK HOUSE STORE) OF 225 COY ASC (SUP) UNDER GE (C) KOLKATA Contract No: GE (C )/KOL/ OF 2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevant columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # ItemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Conversion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words
2M&L PCC type B-1 (1:2:4) (Using 20mm graded crushed stone aggregate) as in column, pillar, piers, posts, struts etc complete all as specified and directed.
3M&L Steel Work in Tubular Trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conform-ing to IS:1161-1979 grade St.-240, complete all as specified and as directed.
4Dismantling of AC (corrugated, semi corrugated, Plain) sheet in roof covering incl ridges complete all as specified and directed.
5S&F Pre-painted galvalume aluminium zinc coating GI based corrugated/semi corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified and directed
6Demolition of brick work or stone masonary built in cement mortor including all quoins & jambs etc. complete all as specified and directed
7Material and Labour Brick work with fly ash pulverized bricks of class designation 75, kgf/cm2 straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
8M&L rendering 15mm thick in CM (1:6) on other than fair faces of brick work or concrete surfaces even & smooth without using extra cement complete all as specified and directed
9M&L 20 mm thick rendering in cement mortar (1:4) on fair faces of brick or concrete external surfaces in one layer finished even and smooth without using extra cement using water proofing compound on top layer @2% by weight of cement or as per manufactures instruction on external wall surface upto height of 4th storied bldg complete all as specified and directed.Note : WPC shall be measured and paid seperately
10M&L for 5 mm thick rendering on concrete surfaces of ceiling in CM 1:3 and finished even and smooth without using extra cement complete all as specified & directed.
11\\"Supply only\\" liquid water proofing compound (ISI marked) complete all as specified and directed.
12Taking down chowkhats or frames with shutters (without taking off shutter from frames) of any sizes nexc 1.5 Sqm each complete all as specified and directed
13All as item No. 09 here in before but exc 1.5 Sqm and nexc 4.0 Sqm each.
14Supply and fixing factory made uPVC white colour Three track three panels sliding window with and including 4.8mm thick tinted glass and fly proof S.S wire mesh, (0.36mm nominal dia of wire and avg width of aperture 1.4mm), Two nos. glazed & one no. wire mesh panels, upto 1.50m height made of (big series) frame 116 x 45 mm & sash 46 x 62 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sashextruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimensionof uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified anddirected by Engineer-in-Charge. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made
15Supply and fixing factory made uPVC white colour Two track Two panels sliding window with and including 4.8mm thick tinted glass and fly proof S.S wire mesh, (0.36mm nominal dia of wire and avg width of aperture 1.4mm), Two nos. glazed & one no. wire mesh panels, upto 1.50m height made of (big series) frame 67 x 80mm & sash 46 x 82mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of window above 1.75 sqm) comprising of uPVC multichambered frame, with inbuilt roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimensionof uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, complete all as specified anddirected by Engineer-in-Charge. Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made
16M&L preparing newly plastered surfaces of wall and applying 2 coat of acrylic distemper over a coat of primer complete all as specified and directed.
17M&L prearation of new plastered surface of wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, Alkali and fungal resistance, dirt resisatance exterior paint of required shade (Company Depot Tinted) with silicon additives @1.43 litre /10sqm over and including priming coat of exterior primer applied @0.90litre/10sqm over new surface complete all as specified and directed
18M&L Non-skid Ceramic Coloured Tiles, 7.0mm to 8.0mm thick (square/rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqm in Floors, etc. Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over 15mm thick screed bed (1:6) in cement mortar complete all as specified and as directed.
19M&L Non-skid Ceramic Coloured Tiles, 7.0mm to 8.0mm thick (square/rectangular), area of each tile exc 0.11 sqm but not exc 0.18 sqm on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layer in cement mortar (1:4) complete all as specified and as directed.
20M&L Glazed Ceramic Coloured Tile 450 x 300 x 7.0mm thick on Vertical Surfaces such as Skirting, Dados, Risers to Steps, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Coloured Cement to match the Shade of the Tiles over and including 10mm thick backing layer in cement mortar (1:4) complete all as specified and as directed.
21M&L Preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel plaint over a coat of red oxide all as specified and directed by Engineer-in-Charge.
22Demolition of cement concrete (Un-reinforced) of any description and in any position not otherwise specifically provided for upto 4 storey bldg height all as specified and directed.
23M&L 75mm thick PCC (1:3:6) type C-2 (Using 40mm graded stone aggregate) as in plinth protection surface even and smooth without using extra cement complete all as specified and directed
24S&F False ceiling with 'E' board \\"Classic\\" , reinforced, designer series, board with HPSC of size 605 mm x 605 mm x 4 mm thick fixed on aluminium powder coated snap grid to support the boards/files with aluminium anodised main 'T' section 35mm x 23mm x 1.50mm cross tee 35mm x 23mm x 1.50mm thick and aluminium angle 25mm x 25mm x 1.40mm as on edges/sides duly suspended with 4mm dia GI hanger fixed with GI hooks 4mm dia and fastner as required at the site and applying two coats of oil bound distemper over a coat of alkali resistant primer on exposed surfaces complete all as specified and as directed.
25M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and directed.
26M&L Mild Steel TMT Bars 8 mm dia , cut to length, bent to shape required including crank-ing, bending and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm, as in stirrups spacers and binders complete all as specified and as directed.
27M&L RCC for M25 (Nominal Mix) using 20mm graded crushed stone aggregate as in parapets, balcony, chajjas and similar work all as specified and directed
28Dismantling Floor, Hearth or Wall Tiling including Cement Mortar Bedding (but not backing), and removing rubbish off the Premises, complete all as specified and as directed.
29M&L for Pressed steel frames for doors with one or more rebates size of frame 125 x 60 mm including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed complete all as specified and directed.Note:-Pressed Steel Frame should be filled with PCC 1:3:6 Type C-0 (Using 12.50mm graded stone aggregate) and cost of PCC shall be deemed included in quoted rate.
30S&F 30mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides fitted to cowkhats complete all as specified and directed
31M&L 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats as specified in SSR Part-I 2009.complete all as specified and directed.
32S&F Sheet Glass 4.0mm thick ordinary quality glazing with Oil Putty in Square or Rectangular, not exc. 0.50 Sqm, complete all as specified and as directed.
33Dismantling of stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in mortar complete all as specified and directed.
34M&L Granite (of any type) Work (Table rubbed and polished) 16 to 18mm thick, in Steps, jam, pillar, window cill, Cooking Platforms and like, Set in Screed bed of 20mm thick in Cement Mortar 1:4 including Pointing in White Cement 1:2 using Marble Dust with admixture of Pigment to match with Shade of Granite including Cutting and Polishing including half round edges, complete all as specified and as directed.
35S&F Machine cut kota stone slab flooring 20mm thick (size 550mmx550mm) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and granite finish polishing complete over 20mm thick 1:6 cement mortar screed bed complete all as specified and as directed.
36M&L mild steel Framed Work such as Grills, Gratings, etc. with ends of Bars shouldered and/or riveted, or forged into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework of Water Tanks and Similar Work, conforming to Fe-290, Gde-E-165, complete all as speci-fied and as directed.
37S&F 300mm long Aluminium alloy, anodised, Sliding Door Bolt with Hasp, Staple (Bolt type) and Fixing Clips of Sheet, Cast or Extruded Sections and Fixing Bolts and Sliding Bolts of Extruded Sections or Cast-Aluminium alloy and fixed, complete all as specified and as directed.
38S&F Aluminium anodised, barrel tower bolts of extruded section, 150 mm long and fixed with steel screws complete all as specified and directed.
39S&F Aluminium alloy Handle 150mm long, Extruded Section, Fabricated type, anodized and fixed, complete all as specified and as directed.
40Taking down Cement Plaster of any descrip-tion on Brick Walls, Concrete Surfaces includ -ing racking out joints, hacking for key, scrubbing down with Water, remove dust, debries/ rubbish, etc., complete all as specified and as directed.
41M&L for preparation of new surfaces of wood and wood based materials of any descriptions not otherwise described over 10Cm width or girth & applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified.
42Demolition of plain concrete (Un-reinforced) in ground floor and paving nexc 15cm thick above or below GL complete all as specified and directed
43M&L 25mm thick providing cement concrete (1:2:4) type B-0 (Using 12.50mm graded stone aggregate) as in base course to floor, finishing surface even and fair to receive floor finishes, complete all as specified and directed.
44M&L for 25mm thick prepolished coloured PCC chequred tiles of size 300x300x25mm set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles with and including 15mm thick screed bed in CM 1:4 complete all as specified and directed
45M&L 75mm thick PCC (1:4:8) type D-2 (Using 40mm graded stone aggregate) as in sub base for path/hard standing cement complete all as specified.
46M&L Preparing new Surfaces of Walls and applying Two Coats of Cement Base Paint over a coat of white wash complete all as specified and as directed.
47M&L for preparing newly plastered surfaces of wall and priming plastered and other surfaces with alkali resistant priming paint on plastered surface and applying two coats of oil bound distemper all as specified and directed
48M&L for preparation of new plastered surface of ceiling and applying two coats of oil bound distemper over one coat of primer Chalk whiting, on plastered surface complete all as specified and directed
49M&L complete removal of exisiting treatment and applying two coats of cement base paint on wall over a coat of primer chalk whiting, on plastered surface, on wall surface complete all as specified and directed
50M&L complete removal of existing finishes oand treating with two coats of oil bound distemper (any colour/tint) on plastered surfaces perparatory to distempering over 2mm thick wall care putty including rubbing with emmery paper to make wall surface smooth and even complete all as directed and specified
51M&L prepartion of existing old ceiling surfaces and applying one coat of oil bound distemper (any colour/tint) on ceiling surface complete all as directed and specified
52Stripping of old tarfelt including layer of plaster or morter of any type treatement carefully from roof surfaces (without damage of roof) and roughening of surface of old concrete roofing by picking sweeping cleaning and washing down with water to remove dust as directed and specified.
53M&L 20mm thick screed bed or bedding layer in CM 1:4 surface finished even and smooth without using extra cement for padding complete all as specified and directed
54M&L for applying tack coat industrial bitumen 85/25 at the rate of 1.2Kg/sqm including cleaning of surface and laying of APP based polymeric membrance minimum weighing 3Kg/sqm and minimum 3mm thick reinforced with polysiter non wove fabric (wt not less than 150gms/sqm) land on priming surfaces by forced application and apply one coat of aluminium paint complete all as specified and directed
55Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody for refixing or for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors, etc. including cleaning all and specified and directed.
56M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium duty with all accessories including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly includingCutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed.Note : Cost of cutting chases, making good and finishes shall be deemed to be included in quoted rate
57All as per item No 55.00 here-in-before but for one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
58All as per item No. 55.00 here-in-before but for one 3 pin 5 amps switch socket outlet on the independent board with other switch complete all as specified and directed by Engineer-in-charge.
59All as per item No.55.00 mentioned here-in-before but using 2.5 sq mm size stranded copper conductor cable for one 3 Pin 16Amp, socket outlet point on independent board complete PVC insulated and unsheathed copper condutor earth continuity conductor to common earth and connecting to earh dolly as specified and directed by Engineer in charge
60All as per item No.55.00 mentioned here-in-before but using 4 sq mm size stranded copper conductor cable for one 3 Pin 16Amp, socket outlet point on independent board complete PVC insulated and unsheathed copper condutor earth continuity conductor to common earth and connecting to earh dolly as specified and directed by Engineer in charge
61S&F A C starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB and one 25 Amps socket complete all as specified and directed by Engineer-in-Charge.
62S&F modular socket outlet 5A, 3 Pin, 2 Module complete all as specified and directed
63S&F modular switch, one way, 6Amp, 1 module complete all as specified and directed
64S&F socket 6A/16A-2/3 pin combined 2 module complete all as specified and as directed
65S&F modular switch 1 way 16A, 1 module complete all as specified and directed
66S&F Ceiling rose surface bakelite three terminals 240 volts complete all as specified and as directed.
67S&F ceiling fan regulator electronic Step Modular type, solid state, 240 volts, complete all as specified and as directed
68S&F LED luminaire 600mm x 600mm, 35/36 Watt, 220V AC recessed/surface type with high efficency PMMA diffuser soft glare free light complete with driver, holder & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed
69S&F sub main wiring two run of single core PVC insulated unsheathed stranded copper conductor of size 6 sqmm & one run of PVC insulated unsheathed stranded copper conductor of size 6 sqm as earth lead drawing into rigid non metalic PVC concealed conduit of size 20mm dia complete all as specified. Note:- (i) Two runs of 6 Sqmm conductor as main wire and one run of 6 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit. (ii) Cutting chasing and making good in CM (1:3) deemed to be included in quoted rate
70Taking down old burnt/unserviceable submain wiring with aluminum/copper conductor PVC insulated cable of any size drawn through PVC casing caping/ PVC Conduit pipe including GI wire accessories etc. and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
71Taking down unserviceable rusted / damaged MCB DBs of any type and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed.
72S&F in replacement sheet metal enclosure distribution board SP&N, 8 way, double door, powder coated protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200Amp rating copper bus bar complete all as specified and directed
73S&F in replacement sheet metal enclosure distribution board SP&N, 4 way, double door, powder coated protection class IP-42, suitable for mounting MCB, DBs confirming to IS-13032, IS-8632, BS-5484 with min 200Amp rating copper bus bar complete all as specified and directed
74S&F Energy efficient LED fittings of capacity 1 x 10W suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length complete all as specified and as directed.
75S&F Energy efficient LED fittings of capacity 1 x 20W suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length complete all as specified and as directed.
76S&F MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve breaking capacity 10 kA complete all as specified and as directed.
77S&F MCB 32 Amps, DP 240 Volts ,C- Curve breaking capacity 10 KA complete all as specified and as directed.
78S&F MCB TPN, 63 Amps 415 Volts , type 'C' curve, 10 KA, complete all as specified & directed.
79S&F MCB DP 40 to 63 Amps 240 Volts , type 'C' curve, 10 KA, complete all as specified & directed.
80S&F building security light pressure die cast housing with individual LEDs with modular secondary optics security light luminaires 35 watt LED with 50mm dia light grade GI pipe bent to shape of 45'' 1.5 mtr long and nuts bolts including fixing arrangement after taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
81M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI wire 4 mm dia as earthing lead by means of bolts, nuts, check nuts and washers of GI wire shall be proected by 15 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and directed.
82Taking down, the ceiling fan / exhaust fan, opening the blades and keeping it in safe coustody and refixing the exhaust fan or ceiling fan upto 1400mm sweep after minor repair and painting at its own position complete all as directed by Engr-in-Charge
83M&L Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exceeding 10 cm girth in brick walls etc complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56925527
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30.89 Lakhs
LAST DATE 28-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for special Repair To Community Hall At Strand Line Area And special Repair To Bldg No S-42A (Cook House Store) Of 225 Coy Asc (Sup) Under Ge (C) Kolkata
Basic Detail
Tender No 8976/E8
Bidding Type Tender
Location
City Kolkata
State West Bengal
Key Dates
Publish Date 08 Aug 2026
Submission Date 28 Aug 2026
Open Date 29 Aug 2026
Finance
Tender Value 30.89 Lakhs
Tender Fee 500
EMD 61798
Exemption Available
Document List
3420a01a-9b34-4356-88a5-80cfa353830a.html
BOQ_877853.xls
TENDER8970.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 13 days
Aug 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

3420a01a-9b34-4356-88a5-80cfa353830a.html

xls

BOQ_877853.xls

pdf

TENDER8970.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders