Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56925468

Tender For Repair And Maintenance Of Lt Panels, Apfc Panels And Connected Items At Lgj Mil Stn Under Ge Lalgarh Jattan

Issued by Statutory Bodies & Commissions/Committees · Ganganagar, Rajasthan
Tender Value
45 Lakhs
Estimated cost
Bid Submission
27 Aug 2026
16 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ganganagar → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Lt Panels, Apfc Panels And Connected Items At Lgj Mil Stn Under Ge Lalgarh Jattan

BOQ

Name of Work:- REPAIR AND MAINT OF LT PANELS, APFC PANELS AND CONNECTED ITEMS AT LGJ MIL STN UNDER GE LALGARH JATTAN
Sl. No. Item Description
1Supply & install, testing and commissioning of factory made,CPRI approved factory made LT panel outdoor KIOSK type with double doors of suitable size provided with locking arrangements dust, weather and vermin proof 1100 volt grade, 50 Hz AC made out by 3.15 mm thick CRCA sheet steel, fully compartmentalised, with IP-65 protection all as per conforming to IS: 2417 of 1962 complete with and 50x50x5 mm thick angle iron for frame and legs, 04 Nos. legs 750 mm long 450 mm grouted in PCC blocks of type B-1 (1:2:4) with 300 mm ground clearance, for 415 volts, 3 phase, 4 wire AC supply complete all as directed with and including the following (a) MCCB 4 pole 415 Volt, 630 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 35 KA - 01 No (incoming)(b) MCCB 4 pole 415 Volt, 250 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 25 KA - 04 No (outgoing)(c) MCCB 4 pole 415 Volt, 125 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 16 KA - 02 No (Outgoing)
2(d)Digital street light Timer Switch with contactor 40A - 01 Nos(e) Digital Voltmeter 96 sqmm 0 - 500V with selector switch - 01 No(f) Digital Ammeter 96 sqmm 0 - 200 Amp with CTs and selector switch - 01 No(g) Aluminium strip bus bars with colour code PVC insulation 800 Amps capacity - 01 Set(h) Indicators RYB - 01 Set(j) Earthing terminals and cable glands.(k) Internal wiring of panel board with solid coductor copper cable single core of sutable size and incl 03 Nos bakelite control fuses.[l] Danger notice plate for LT with conventional skull and bones duly rivetted/pasted to the panel board door.
3Supply & install, testing and commissioning of factory made,CPRI approved factory made LT panel outdoor KIOSK type with double doors of suitable size provided with locking arrangements dust, weather and vermin proof 1100 volt grade, 50 Hz AC made out by 3.15 mm thick CRCA sheet steel, fully compartmentalised, with IP-65 protection all as per conforming to IS: 2417 of 1962 complete with and 50x50x5 mm thick angle iron for frame and legs, 04 Nos. legs 750 mm long 450 mm grouted in PCC blocks of type B-1 (1:2:4) with 300 mm ground clearance, for 415 volts, 3 phase, 4 wire AC supply complete all as directed with and including the following (a) MCCB 4 pole 415 Volt, 400 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 35 KA - 01 No (incoming)(b) MCCB 4 pole 415 Volt, 200 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 25 KA - 02 No (outgoing)(c) MCCB 4 pole 415 Volt, 125 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 10 KA - 02 No (Outgoing)(d) MCCB 4 pole 415 Volt, 63 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 25 KA - 04 No (Outgoing)
4(e)Digital street light Timer Switch with contactor 40A - 01 Nos(f) Digital Voltmeter 96 sqmm 0 - 500V with selector switch - 01 No(g) Digital Ammeter 96 sqmm 0 - 200 Amp with CTs and selector switch - 01 No(h) Aluminium strip bus bars with colour code PVC insulation 800 Amps capacity - 01 Set(j) Indicators RYB - 01 Set(k) Earthing terminals and cable glands.(l) Internal wiring of panel board with solid coductor copper cable single core of sutable size and incl 03 Nos bakelite control fuses.(m) Danger notice plate for LT with conventional skull and bones duly rivetted/pasted to the panel board door.
5Supply & install, testing and commissioning of factory made,CPRI approved factory made LT panel outdoor KIOSK type with double doors of suitable size provided with locking arrangements dust, weather and vermin proof 1100 volt grade, 50 Hz AC made out by 3.15 mm thick CRCA sheet steel, fully compartmentalised, with IP-65 protection all as per conforming to IS: 2417 of 1962 complete with and 50x50x5 mm thick angle iron for frame and legs, 04 Nos. legs 750 mm long 450 mm grouted in PCC blocks of type B-1 (1:2:4) with 300 mm ground clearance, for 415 volts, 3 phase, 4 wire AC supply complete all as directed with and including the following (a) MCCB 4 pole 415 Volt, 400 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 35 KA - 01 No (incoming)(b) MCCB 4 pole 415 Volt, 250 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 25 KA - 03 No (outgoing)(c) MCCB 4 pole 415 Volt, 125 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 10 KA - 02 No (Outgoing)
6(d)Digital street light Timer Switch with contactor 40A - 01 Nos(e) Digital Voltmeter 96 sqmm 0 - 500V with selector switch - 01 No(f) Digital Ammeter 96 sqmm 0 - 200 Amp with CTs and selector switch - 01 No(g) Aluminium strip bus bars with colour code PVC insulation 800 Amps capacity - 01 Set(h) Indicators RYB - 01 Set(j) Earthing terminals and cable glands.(k) Internal wiring of panel board with solid coductor copper cable single core of sutable size and incl 03 Nos bakelite control fuses.(l) Danger notice plate for LT with conventional skull and bones duly rivetted/pasted to the panel board door.
7Supply & install, testing and commissioning of factory made,CPRI approved factory made LT panel outdoor KIOSK type with double doors of suitable size provided with locking arrangements dust, weather and vermin proof 1100 volt grade, 50 Hz AC made out by 3.15 mm thick CRCA sheet steel, fully compartmentalised,seperate cable alley, cable gland with IP-65 protection all as per conforming to IS: 2417 of 1962 complete with and 50x50x5 mm thick angle iron for frame and legs, 04 Nos. legs 750 mm long 450 mm grouted in PCC blocks of type B-1 (1:2:4) with 300 mm ground clearance, for 415 volts, 3 phase, 4 wire AC supply complete all as directed with and including the following (a) MCCB 4 pole 415 Volt, 200 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 36 KA - 01 No (incoming)(b) MCCB 4 pole 415 Volt, 125 Amps ,Adjustable thermal and magnetic release manual drawout type setting rupture capacity 25 KA - 04 No (outgoing)( c) MCB TPN 415 Volt, 32 Amp, 10KA-01 Nos(d) Digital Voltmeter 96 sqmm 0 - 500V with selector switch - 01 No( e) Digital Ammeter 96 sqmm 0 - 200 Amp with CTs and selector switch - 01 No(f) Aluminium strip bus bars with colour code PVC insulation 300 Amps capacity - 01 Set(g) Indicators RYB - 01 Set(h) Earthing terminals and cable glands.(i) Internal wiring of panel board with solid coductor copper cable single core of sutable size and incl 03 Nos bakelite control fuses.(j) Danger notice plate for LT with conventional skull and bones duly rivetted/pasted to the panel board door.
8Supply & Fixing in replacement of MCCB 630 Amps, 4 pole, 415 Volts , 36KA, Ics=100% Icu Adjustable Thermal (0.8 to 1 x In) and Fixed Magnetic Release, complete all as specified and directed by the Engineer in Charge.
9Supply & Fixing in replacement of MCCB 400 Amps, 4 pole, 415 Volts , 36KA, Ics=100% Icu Adjustable Thermal (0.8 to 1 x In) and Fixed Magnetic Release, complete all as specified and directed by the Engineer in Charge.
10Supply & Fixing in replacement of MCCB 250 Amps, 4 pole, 415 Volts , 25KA, Ics=100% Icu Adjustable Thermal (0.8 to 1 x In) and Fixed Magnetic Release, complete all as specified and directed by the Engineer in Charge.
11Supply & Fixing in replacement of MCCB 200 Amps, 4 pole, 415 Volts , 25KA, Ics=100% Icu Adjustable Thermal (0.8 to 1 x In) and Fixed Magnetic Release, complete all as specified and directed by the Engineer in Charge.
12Supply & Fixing in replacement of MCCB 160 Amps, 4 pole, 415 Volts , 25KA, Ics=100% Icu Adjustable Thermal (0.8 to 1 x In) and Fixed Magnetic Release, complete all as specified and directed by the Engineer in Charge.
13Supply & Fixing in replacement of MCCB 100 Amps, 4 pole, 415 Volts , 25KA, Ics=100% Icu Adjustable Thermal (0.8 to 1 x In) and Fixed Magnetic Release, complete all as specified and directed by the Engineer in Charge.
14S & F in replacement Digital Voltmeter 0-500 volts of size 96 x 96 mm complete all as specified and directed by Engr-in-charge.
15S & F in replacement Digital Ammeter 0-200 Amp of size 96 x 96 mm complete all as specified and directed by Engr-in-charge.
16Material and labour for repair LT panel board by necessary welding to door hinges and fixing the sliding bolt for proper locking arrangement and making good all electric connection of LT panel of any size incl replacement of rubber gasket and spray painting complete panel with synthetic enamel paint over a coat of red oxide incl preparation of old surface, refreshing all the cable connection and control wiring complete all as specified and directed by Engr-in-charge.Note : 1. charges for replacement of minor part viz nut bolts, thimble, control wires etc are included in this item.2. Major part viz MCCB, Ammeter, Voltmeter etc will be measured and paid separately.
17Supply,Laying and testing in replacement of PVC LT Cable of size 185 Sqmm, 3.5 core, 1100 Volt grade heavy duty with PVC insulated standard aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip and over all PVC Sheathed stranded conductor conforming to IS- 7098 (Part-I) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge.
18Supply and fixing Aluminium thimble of size 185 sqmm complete all as specified and directed by Engr-in-charge.
19Supply & Fixing in replacement of MCCB 63 Amps, 4 pole, 415 Volts , 25KA, Ics=100% Icu Adjustable Thermal (0.8 to 1 x In) and Fixed Magnetic Release, complete all as specified and directed by the Engineer in Charge.
20Supply & install, testing & commissioning in repairs LT APFC panel -75 KVAR compartmental out door type, Lockable fabrication made by 3.15 mm thick sheet CRCA approved machine pressed, dust and vermin, weather proof design framed on angle iron (40mmx40mmx6mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, including with 4 \\" Exhaust Fan along with air vents, Capacitor on/off indicators and A/M Selector switch for all Capacitors and cable entry with glands with all control wiring and thimbles etc, foundation /grouting on & including PCC work as per site requirement with the following :-(a) Copper bus bar 250 Amp Cap- 1 Set ( Set of 4 strips)(b) MCCB 200 Amp 415V TPN with spreader links, 36 KA- 1 No (incoming)(c) 25 KVAR Capacitor Heavy Duty - 2 Nos(Outgoing) (d) Capacitor duty contactor MO C25 - 2 Nos(Outgoing)(e) MCCB 63 Amp, TP ,10 KA - 2 Nos(Outgoing)(f) 10 KVAR Capacitor Heavy Duty - 1 Nos(Outgoing) (g) Capacitor duty contactor MO C10 - 1 Nos(Outgoing)(h) MCCB 20 Amp, TP ,10 KA - 1 Nos(Outgoing) (j) 5 KVAR Capacitor Heavy Duty - 2 Nos(Outgoing) (k) Capacitor duty contactor MO C5 - 2 Nos(Outgoing)(l) MCCB 16 Amp, TP ,10 KA - 2 Nos(Outgoing)
21(m) 2 KVAR Capacitor Heavy Duty - 2 Nos(Outgoing) (n) Capacitor duty contactor MO C2 - 2 Nos(Outgoing)(o) MCCB 10 Amp, TP ,10 KA - 2 Nos(Outgoing) (p) 1 KVAR Capacitor Heavy Duty - 1 Nos(Outgoing) (q) Capacitor duty contactor MO C1 - 1 Nos(Outgoing)(r) MCCB 6 Amp, TP ,10 KA - 1 Nos(Outgoing)(s) indicating fuse LED type R,Y,B - 03 Nos(t) VAF meter 3 Phase-01 Nos(u) Control MCB SP 6 Amps -03 Nos(v) CT Coil 200/5 Amps -03 Nos and 250/5 Amp -01 Nos(w) APFC Relay 8 Set - 01 Nos
22Supply & install, testing & commissioning in repairs LT APFC panel -100 KVAR compartmental out door type, Lockable fabrication made by 3.15 mm thick sheet CRCA approved machine pressed, dust and vermin, weather proof design framed on angle iron (40mmx40mmx6mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, including with 4 \\" Exhaust Fan along with air vents, Capacitor on/off indicators and A/M Selector switch for all Capacitors and cable entry with glands with all control wiring and thimbles etc, foundation /grouting on & including PCC work as per site requirement with the following :-(a) Copper bus bar 250 Amp Cap- 1 Set ( Set of 4 strips)(b) MCCB 200 Amp 415V TPN with spreader links, 36 KA- 1 No (incoming)(c) 25 KVAR Capacitor Heavy Duty - 2 Nos(Outgoing) (d) Capacitor duty contactor MO C25 - 2 Nos(Outgoing)(e) MCCB 63 Amp, TP ,10 KA - 2 Nos(Outgoing)(f) 15 KVAR Capacitor Heavy Duty - 2 Nos(Outgoing) (g) Capacitor duty contactor MO C15 - 2 Nos(Outgoing)(h) MCCB 32 Amp, TP ,10 KA - 2 Nos(Outgoing)(j) 10 KVAR Capacitor Heavy Duty - 1 Nos(Outgoing) (k) Capacitor duty contactor MO C10 - 1 Nos(Outgoing)(l) MCCB 20 Amp, TP ,10 KA - 1 Nos(Outgoing)
23(m) 5 KVAR Capacitor Heavy Duty - 1 Nos(Outgoing) (n) Capacitor duty contactor MO C5 - 1 Nos(Outgoing)(o) MCCB 16 Amp, TP ,10 KA - 1 Nos(Outgoing)(p) 2 KVAR Capacitor Heavy Duty - 2 Nos(Outgoing) (q) Capacitor duty contactor MO C2 - 2 Nos(Outgoing)(r) MCCB 10 Amp, TP ,10 KA - 2 Nos(Outgoing)(s) 1 KVAR Capacitor Heavy Duty - 1 Nos(Outgoing) (t) Capacitor duty contactor MO C1 - 1 Nos(Outgoing)(u) MCCB 6 Amp, TP ,10 KA - 1 Nos(Outgoing)(v) indicating fuse LED type R,Y,B - 03 Nos(w) VAF meter 3 Phase-01 Nos(x) Control MCB SP 6 Amps -03 Nos(y) CT Coil 200/5 Amps -03 Nos and 250/5 Amp -01 Nos(z) APFC Relay 8 Set - 01 Nos
24Material and labour for Servicing/repair LT APFC panel board by disconnection of power supply from panel, necessary welding to door hinges and fixing the sliding bolt for proper locking arrangement and making good all electric connection and ensuring the serviciability of LT APFC panel of any size incl replacement of rubber gasket and spray painting complete panel with synthetic enamel paint over a coat of red oxide incl preparation of old surface complete all as specified and directed by Engr-in-charge.Note : 1. charges for replacement of minor part viz nut bolts, thimble,insulation tape, Conrol wiring etc are included in this item.2. Major part viz MCCB, Ammeter, Voltmeter,relay,contactor , capacitor , MCBs etc will be measured and paid separately.
25Supply and fixing in replacement of heavy duty 50 KVAR Capacitor cylindrical type fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
26Supply and fixing in replacement of heavy duty 25 KVAR Capacitor cylindrical type fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
27Supply and fixing in replacement of heavy duty 15 KVAR Capacitor cylindrical type fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
28Supply and fixing in replacement of heavy duty 10 KVAR Capacitor cylindrical type fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
29Supply and fixing in replacement of heavy duty 5 KVAR Capacitor cylindrical type fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
30Supply and fixing in replacement of heavy duty 2 KVAR Capacitor cylindrical type fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
31Supply and fixing in replacement of heavy duty 1 KVAR Capacitor cylindrical type fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
32Supply and fixing in replacement of 50 KVAR Capacitor MOC50 heavy duty contactor fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
33Supply and fixing in replacement of 25 KVAR Capacitor MOC 25 heavy duty contactor fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
34Supply and fixing in replacement of 15 KVAR Capacitor MOC15 heavy duty contactor fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
35Supply and fixing in replacement of 10 KVAR Capacitor MOC10 heavy duty contactor fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
36Supply and fixing in replacement of 5 KVAR Capacitor MOC10 heavy duty contactor fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
37Supply and fixing in replacement of 2 KVAR Capacitor MOC2/3 heavy duty contactor fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
38Supply and fixing in replacement of 1 KVAR Capacitor MOC2/3 heavy duty contactor fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
39Supply and fixing in replacement of MCB TP 100 Amp 'C' Curve, 10 KA Breaking Capacity fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
40Supply and fixing in replacement of MCB TP 63 Amp 'C' Curve, 10 KA Breaking Capacity fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
41Supply and fixing in replacement of MCB TP 32 Amp 'C' Curve, 10 KA Breaking Capacity fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
42Supply and fixing in replacement of MCB TP 20 Amp 'C' Curve, 10 KA Breaking Capacity fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
43Supply and fixing in replacement of MCB TP 16 Amp 'C' Curve, 10 KA Breaking Capacity fixed in existing APFC Panel complete all as specified and directed by Engr-In-Charge.
44Supply and fixing in replacement of APFC Relay 16 Stages in existing APFC panel suitable for connection/disconnection of capacitors in the system by sensing current and voltage. The relays shall be operable with 3 phase 415-440 volt, 50 Hz AC power supply suitable with existing APFC panel and existing CTs. The relay shall have following functions/features (a) Display parameters :- PF, Volt, current, kVAr, kVA, HZ, temperature (b) Power factor control range :- 0.3 lag to 0.3 lead (c) IP-20 protection (d) Operating temperature :- 20 degree celsius to 60 degree celsius (e) Humidity : 0 to 90% (f) Automatic detection of CT polarity (g) capacitor health check function complete all as specified and directed by Engr-In-Charge.
45Ditto all as per srl item No 39.00 above, but 12 stages complete all as specified and as directed.
46Ditto all as per srl item No 39.00 above, but 08 stages complete all as specified and as directed.
47S&F in replacement current tranformer (CT) suitable for existing LT APFC panel having 200/5 Amps ratio, 10 VA burden, and class 1.0 complete all as specified and directed by Engineer in charge
48Material and labour for removal / scraping of existing panel and with two coat of synthetic enemal paint after primer with red oxide complete all as specified and directed by Engr-in-charge.
49S&F in repair cable joint kit 1100 Volts straight through complete of size 25 to 50 sq mm complete
50S&F in repair cable joint kit 1100 Volts straight through complete of size 70 to 150 sq mm complete
51S&F in repair cable joint kit 1100 Volts straight through complete of size above 185 to 300 sq mm complete
52Material and labour for Earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32 X 6 mm (upto the body of equipment) by means of GI bolts/nuts/washers/check nuts of galvanised iron all as shown in electrical plate No.3 of SSR Part-I, Connected to equipment all as specified and testing on completion including provision of earth lead protection by 40 mm bore GI light grade pipe and watering pipe shall be 20 mm bore GI Med grade including funnel and wire mesh. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom, RCC cover in 1:2:4 type B1using 20mm graded crushed stone aggregate and reinfircement with8mm dia @ 100 c/c/ bothbays & frame, PCC (1:3:6) type C2 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work complete all as specfied and directed by Engr-In-ChargeNote:- Rates quoted by the tenderer shall be deemed to be included for following provisions.(i) Excavation and earth work in any type of soil including removal of surplus soil upto 100 Mtrs(ii) PCC 1:3:6 Type C-1 mix using 20 mm graded stone aggregate in pipe and 40 mm thick precast RCC 1:2:4 Type B1 using 20 mm graded stone aggregate with 8 mm dia round bars @ 75 mm c/c both ways(iii) Main earthing lead from earth electrode to equipment upto 7.5 Mtr(iv) Funnel with watering pipe GI Med Grade 20 MM Dia (ISI Marked) and lugs, charcoal and salt as required(v) GI Protection Pipe of size 40 mm dia light grade 7.5 Mtrs Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56925468
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 27-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Lt Panels, Apfc Panels And Connected Items At Lgj Mil Stn Under Ge Lalgarh Jattan
Basic Detail
Tender No 8937-27/GE/2026-27
Bidding Type Tender
Location
City Ganganagar
State Rajasthan
Key Dates
Publish Date 08 Aug 2026
Submission Date 27 Aug 2026
Open Date 29 Aug 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
968d47aa-fdc1-4528-bc07-c195f93e5160.html
BOQ_877890.xls
tender.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Aug 29, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

968d47aa-fdc1-4528-bc07-c195f93e5160.html

xls

BOQ_877890.xls

pdf

tender.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders