Public Administrative Department Government Departments Closing in 1 days TDR #56923887

Tender For Construction Of City Entrance Gateways Of Kanpur City.

Issued by Government Departments · Kanpur, Uttar Pradesh
Tender Value
19.81 Crore
Estimated cost
Bid Submission
25 Aug 2026
1 days left
EMD
1.01 Crore
Bank guarantee accepted
Document Fee
25738
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanpur → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of City Entrance Gateways Of Kanpur City.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 14-Aug-2026 PRE-BID MEETING DATE Other 25-Aug-2026
2 14-Aug-2026 EMD Fee 25-Aug-2026
3 14-Aug-2026 DATE EXTENSION Date 25-Aug-2026

BOQ

Name of Work:- CONSTRUCTION OF CITY ENTRANCE GATEWAYS OF KANPUR CITY.
Sl. No. Item Description
1BHAUTI ENTRY POINTSurface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
2Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) 400 mm dia piles(2767.00)(.735X112/110)=2070.72
3Bentonite(3050.00)(.735X112/110)=2282.51
4Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.(3551.30)(.735X112/110)=2657.63
5Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 30 m and for all lift, as directed by Engineer in-charge. All kinds of soil
6Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
7Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.(494.10)(.735X112/110)=369.77
8Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
9Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
10Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete all work up to plinth level work; Concrete of M25 grade with minimum cement content of 330 kg /cum excluding the cost of centering and shuttering
11Reinforced cement concrete work in beams, columns suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
12Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete.
13Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc.
14Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
15Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers.
16Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).(515.60)(.735X112/110)=385.86
17Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift
18Brick work with common burnt clay F.P.S. (non modular) bricks of class-7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
19Brick work with common burnt clay F.P.S. (non modular) bricks of class-7.5 in superstructure above plinth up to floor V level in: Cement mortar 1:4 (1 cement : 4 coarse sand)
20Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes (206.35)(.735X112/110)=154.42
2112 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
2215 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand)
23Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
24Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
25Granite stone slab of colour black, Cherry/Ruby red : Area of slab upto 0.50 sqm
26Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).(769.6)(.735X112/110)=575.94
27CNC work - Engineered stone /metal / cotton metal composite vertical wall carved caldding panels fixed / bolted / welded on existing trusses. the art pannels to be fabricated and installation to be done in following steps: (1) Fixinging of partialy carved base metal members incuding fixing of cramps / bolts / studs as per approved drawings department/Architect/Engineer (2) cnc cut carving and instalation of subsidiary panels in position by welding/bolting etc complete (3) instalation on CNC carved metal models / artifacts / symbols / specifics etc by welding, fastners, studs as per approved drawings etc complete (4) Buffing / polishing / finishing of installed CNC carved metal art works to get real life effects.
28Add for Elevational CNC stone art work on coping, other oramental work (moulding work on column and edges, bases ornamental work )
29Lettering & signage works including preparation & fixing plaque for branding of the city identity
30Providing, supplying, installing, testing and commissioning of complete integrated landscaping works including site clearance, excavation, leveling, soil bed preparation with minimum 300 mm thick fertile top soil mixed with organic manure, plantation of approved shrubs, hedges, ornamental plants, ground covers, turfing with natural grass and small decorative trees, edge treatment with stone / precast kerbs and all labour, materials, scaffolding, tools, transportation and incidentals complete as per approved drawings, specifications and directions ofEngineer-in-Charge
31Supply , Installation, Testing & Commissining of Exterior IP66 LED 2700/3000k with SS grill protection for vandal proof ,Neon Flexible light strip of 5 mtr standard length with 11 Watt per meter which can be compatible with the DMX / Ethernet controller. Minimum System lumens of minimum 1150 lumens/meter and System Lumen Efficacy > 82lm/w. Luminaire light beam spread - 110°, The Strip should have IP 66 protection and is offered IP 67 rated connector to join the LED Strips incontinuity. The luminaire must be offered with Aluminum channel for mounting the strip lights. The product should be complete with all accessories and Driver. The successful bidder shall submit the following certifications/reports for approval before SITC of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables.
32Supply , Installation, Testing & Commissining of Circular shape architectural RGBW (W=4000K) with SS grill protection for vandal proof LED flood light with integral driver & housing made of Die-cast aluminium alloy - ADC12. The luminaire shall be no bigger than Ø 225 X 162 without bracket. The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°. The bracket shall have locking mechanism to fix & secure the desired tilt angle. The luminaire shall have silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. The luminaire must have a breather gland. The nominal weight of the luminaire shall be 6KG. The luminaire shall be equipped with high- power Cree, osram, lumiled or equivalent. The fixture shall have 15° beam angle (±10%) & the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage not exceeding 50W and system lumen output of not less than 2230 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have an integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall give feedback on luminaire address & status (ON & Off).
33Supply , Installation, Testing & Commissining of Circular shape DOT luminaire ,with SS grill protection for vandal proof ,diirect view RGBNW max power 9 watts , min 290 lumens,32 lumens/watt with polycarbonate bowl , beam spread 160 degree, 24v DC and .9 power factor housing made of Die cast aluminium IP 66 & IK 06.The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand- held addressing device. The luminaire shall give feedback on luminaire address & status (ON & Off). The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. The luminaire shall be capable of digital dimming of 65536 steps. The successful bidder shall submit the following certifications/reports for approval before SITC of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables
34Supply and Fixing of RDM-6 Wall DMX Splitter & Booster is a 6- output DMX/RDM splitter with DMX/RDM pass-through supporting bi- directionalcom munications for discovery, addressing and DMX control of Philips Vaya products. This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6 X 32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Key Features 1:6-way DMX/RDM Splitter / Booster, Isolated DMX/RDM Input/Outputs ,RDM mode Surface or DIN-rail mountable& AC adaptor included.
35Supply and fixing of Single DMX ports control up to 340 light addresses, Works as a stand-alone or com-puter-driven controller, - Secure Digital (SD) card drive for flexible show storage - USB 2.0 interface for download-ing shows and configuring from attached PC or Mac :Simple installation and wiring is required - Flexible, adaptable mounting options are expected - Should be provided with light show authoring software - Direct line voltage power sup-ports 100 — 240 VAC - Six configurable effects by push buttons on player — Using light show authoring software to select from six effects, adjust effect settings such as color, speed, and brightness.
36Supply , Installation and testing of Panel 15 KVA 3 Phase & Servo MCB 6-32 amp 12 pcs , 32 amp TPN 10 KA 1 pcs
37Installation of GEL EARTHING with GI Strip to earthing along with existing cable
38Supply and Laying of PVC pipe 25 MM
39Supply and Laying of PVC pipe 32 MM
40Supply and laying with 32 MM GI pipe ISI
41Supply and laying 10 * 4 Core armoured aluminium cable
42Supply and fixing IP 65 boxes
43NARAMAU ENTRY POINTSurface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
44Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) 400 mm dia piles(2767.00)(.735X112/110)=2070.72
45Bentonite(3050.00)(.735X112/110)=2282.51
46Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.(3551.30)(.735X112/110)=2657.63
47Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 30 m and for all lift, as directed by Engineer in-charge. All kinds of soil
48Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
49Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.(494.10)(.735X112/110)=369.77
50Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
51Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
52Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete all work up to plinth level work; Concrete of M25 grade with minimum cement content of 330 kg /cum excluding the cost of centering and shuttering
53Reinforced cement concrete work in beams, columns suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
54Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete.
55Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc.
56Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
57Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers.
58Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).(515.60)(.735X112/110)=385.86
59Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift
60Brick work with common burnt clay F.P.S. (non modular) bricks of class-7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
61Brick work with common burnt clay F.P.S. (non modular) bricks of class-7.5 in superstructure above plinth up to floor V level in: Cement mortar 1:4 (1 cement : 4 coarse sand)
62Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes (206.35)(.735X112/110)=154.42
6312 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
6415 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand)
65Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
66Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
67Granite stone slab of colour black, Cherry/Ruby red : Area of slab upto 0.50 sqm
68Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).(769.6)(.735X112/110)=575.94
69CNC work - Engineered stone in wood combination /metal / cotton metal composite vertical wall truss panels fixed / bolted / welded on foundation bolts etc. The wall vertical trussed to be fabricated and installation to be done in following steps: (1) Fixinging of partialy carved vertical metal members incuding fixing of foundation bolts as per approved drawings department/Architect/Engineer (2) Fabrication and instalation of support bracings in position by welding/bolting etc complete (3) instalation on CNC carved metal models / artifacts / symbols / specifics etc by welding, fastners, studs as per approved drawings etc complete (4) Buffing / polishing / finishing of installed CNC carved metal art works to get real life effects.
70Add for Elevational CNC stone art work on coping, other oramental work (moulding work on column and edges, bases ornamental work )
71Lettering & signage works including preparation & fixing plaque for branding of the city identity
72Providing, supplying, installing, testing and commissioning of complete integrated landscaping works including site clearance, excavation, leveling, soil bed preparation with minimum 300 mm thick fertile top soil mixed with organic manure, plantation of approved shrubs, hedges, ornamental plants, ground covers, turfing with natural grass and small decorative trees, edge treatment with stone / precast kerbs and all labour, materials, scaffolding, tools, transportation and incidentals complete as per approved drawings, specifications and directions ofEngineer-in-Charge
73Supply , Installation, Testing & Commissining of Exterior IP66 LED 2700/3000k with SS grill protection for vandal proof ,Neon Flexible light strip of 5 mtr standard length with 11 Watt per meter which can be compatible with the DMX / Ethernet controller. Minimum System lumens of minimum 1150 lumens/meter and System Lumen Efficacy > 82lm/w. Luminaire light beam spread - 110°, The Strip should have IP 66 protection and is offered IP 67 rated connector to join the LED Strips incontinuity. The luminaire must be offered with Aluminum channel for mounting the strip lights. The product should be complete with all accessories and Driver. The successful bidder shall submit the following certifications/reports for approval before SITC of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables.
74Supply , Installation, Testing & Commissining of Circular shape architectural RGBW (W=4000K) with SS grill protection for vandal proof LED flood light with integral driver & housing made of Die-cast aluminium alloy - ADC12. The luminaire shall be no bigger than Ø 225 X 162 without bracket. The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°. The bracket shall have locking mechanism to fix & secure the desired tilt angle. The luminaire shall have silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. The luminaire must have a breather gland. The nominal weight of the luminaire shall be 6KG. The luminaire shall be equipped with high- power Cree, osram, lumiled or equivalent. The fixture shall have 15° beam angle (±10%) & the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage not exceeding 50W and system lumen output of not less than 2230 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have an integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall give feedback on luminaire address & status (ON & Off).
75Supply , Installation, Testing & Commissining of Circular shape DOT luminaire ,with SS grill protection for vandal proof ,diirect view RGBNW max power 9 watts , min 290 lumens,32 lumens/watt with polycarbonate bowl , beam spread 160 degree, 24v DC and .9 power factor housing made of Die cast aluminium IP 66 & IK 06.The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand- held addressing device. The luminaire shall give feedback on luminaire address & status (ON & Off). The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. The luminaire shall be capable of digital dimming of 65536 steps. The successful bidder shall submit the following certifications/reports for approval before SITC of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables
76Supply and Fixing of RDM-6 Wall DMX Splitter & Booster is a 6- output DMX/RDM splitter with DMX/RDM pass-through supporting bi- directionalcom munications for discovery, addressing and DMX control of Philips Vaya products. This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6 X 32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Key Features 1:6-way DMX/RDM Splitter / Booster, Isolated DMX/RDM Input/Outputs ,RDM mode Surface or DIN-rail mountable& AC adaptor included.
77Supply and fixing of Single DMX ports control up to 340 light addresses, Works as a stand-alone or com-puter-driven controller, - Secure Digital (SD) card drive for flexible show storage - USB 2.0 interface for download-ing shows and configuring from attached PC or Mac :Simple installation and wiring is required - Flexible, adaptable mounting options are expected - Should be provided with light show authoring software - Direct line voltage power sup-ports 100 — 240 VAC - Six configurable effects by push buttons on player — Using light show authoring software to select from six effects, adjust effect settings such as color, speed, and brightness.
78Supply , Installation and testing of Panel 15 KVA 3 Phase & Servo MCB 6-32 amp 12 pcs , 32 amp TPN 10 KA 1 pcs
79Installation of GEL EARTHING with GI Strip to earthing along with existing cable
80Supply and Laying of PVC pipe 25 MM
81Supply and Laying of PVC pipe 32 MM
82Supply and laying with 32 MM GI pipe ISI
83Supply and laying 10 * 4 Core armoured aluminium cable
84Supply and fixing IP 65 boxes
85GANGA BAIRAJ DWARSurface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
86Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) 400 mm dia piles(2767.00)(.735X112/110)=2070.72
87Bentonite(3050.00)(.735X112/110)=2282.51
88Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.(3551.30)(.735X112/110)=2657.63
89Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 30 m and for all lift, as directed by Engineer in-charge. All kinds of soil
90Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
91Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.(494.10)(.735X112/110)=369.77
92Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
93Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
94Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete all work up to plinth level work; Concrete of M25 grade with minimum cement content of 330 kg /cum excluding the cost of centering and shuttering
95Reinforced cement concrete work in beams, columns suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
96Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete.
97Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc.
98Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
99Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers.
100Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).(515.60)(.735X112/110)=385.86
101Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift
102Brick work with common burnt clay F.P.S. (non modular) bricks of class-7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
103Brick work with common burnt clay F.P.S. (non modular) bricks of class-7.5 in superstructure above plinth up to floor V level in: Cement mortar 1:4 (1 cement : 4 coarse sand)
104Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand)
10512 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
10615 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand)
107Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: In one coat(713.20)(.735X112/110)=533.73
108Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
109Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
110Granite stone slab of colour black, Cherry/Ruby red : Area of slab upto 0.50 sqm
111Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).(769.6)(.735X112/110)=575.94
112CNC work - Glass fiber reinforced concrete/ concrete casting/Engineered stone/sand stone/metal composite materials Sculpture work cladded in pillar, beam, dome, statues, etc. The manufacturing and installation to be done in following steps: (1) Preparation of initial models in white clay according to the pictures photo and their approval by department/Architect/Engineer (2) Construction of model on top of clay models with plaster of paris (3) Die casting the plaster of paris model (4) Finishing the models with sand paper and applying duco putty and finishing again to get real life effects. (5) Coloring the models with good quality spray applied oil colours. (6) Packing wrapped in bubble and transported safely to the site and installed on firm concrete base at the designated location
113Add for Elevational work of & other oramental work (moulding work on column and water flow cove ornamental work )
114Lettering & signage works including preparation & fixing plaque for branding of the departmet
115Supply, fabrication, transportation and installation of a complete 7-metre high Water wave artifact system showing ganga udgama consisting of a polygonal/continuously tapered Metal / GFRC / Engineered stone with base plate, foundation bolts, internal conduit provision, hoisting mechanism, stainless-steel elements and all required accessories; non-shrink grouting; erection of the system using crane and proper safety measures with full alignment and verticality checks; and all labour, materials, tools, machinery, transport, loading/unloading and incidental works included, complete in all respects as per approved drawings and specifications and direction of Engineer incharge,
116Supply, fabrication, transportation and installation of a Circular / Oval shape Metal Artifact having CNC cut theme inside the perimeter, visuals complete including provision of integrated lightning conduite / cove system consisting of base plate, foundation bolts, hoisting mechanism, and all required accessories; non-shrink grouting; erection of the system using crane and proper safety measures with full alignment and verticality checks; and all labour, materials, tools, machinery, transport, loading/unloading and incidental works included, complete in all respects as per approved drawings and specifications and direction of Engineer incharge,
117Providing, supplying, installing, testing and commissioning of complete integrated landscaping works including site clearance, excavation, leveling, soil bed preparation with minimum 300 mm thick fertile top soil mixed with organic manure, plantation of approved shrubs, hedges, ornamental plants, ground covers, turfing with natural grass and small decorative trees, edge treatment with stone / precast kerbs and all labour, materials, scaffolding, tools, transportation and incidentals complete as per approved drawings, specifications and directions ofEngineer-in-Charge
118Supply , Installation, Testing & Commissining of Exterior IP66 LED 2700/3000k with SS grill protection for vandal proof ,Neon Flexible light strip of 5 mtr standard length with 11 Watt per meter which can be compatible with the DMX / Ethernet controller. Minimum System lumens of minimum 1150 lumens/meter and System Lumen Efficacy > 82lm/w. Luminaire light beam spread - 110°, The Strip should have IP 66 protection and is offered IP 67 rated connector to join the LED Strips incontinuity. The luminaire must be offered with Aluminum channel for mounting the strip lights. The product should be complete with all accessories and Driver. The successful bidder shall submit the following certifications/reports for approval before SITC of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables.
119Supply , Installation, Testing & Commissining of Circular shape architectural RGBW (W=4000K) with SS grill protection for vandal proof LED flood light with integral driver & housing made of Die-cast aluminium alloy - ADC12. The luminaire shall be no bigger than Ø 225 X 162 without bracket. The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°. The bracket shall have locking mechanism to fix & secure the desired tilt angle. The luminaire shall have silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. The luminaire must have a breather gland. The nominal weight of the luminaire shall be 6KG. The luminaire shall be equipped with high- power Cree, osram, lumiled or equivalent. The fixture shall have 15° beam angle (±10%) & the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage not exceeding 50W and system lumen output of not less than 2230 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have an integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall give feedback on luminaire address & status (ON & Off).
120Supply , Installation, Testing & Commissining of Circular shape DOT luminaire ,with SS grill protection for vandal proof ,diirect view RGBNW max power 9 watts , min 290 lumens,32 lumens/watt with polycarbonate bowl , beam spread 160 degree, 24v DC and .9 power factor housing made of Die cast aluminium IP 66 & IK 06.The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand- held addressing device. The luminaire shall give feedback on luminaire address & status (ON & Off). The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. The luminaire shall be capable of digital dimming of 65536 steps. The successful bidder shall submit the following certifications/reports for approval before SITC of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables
121Supply and Fixing of RDM-6 Wall DMX Splitter & Booster is a 6- output DMX/RDM splitter with DMX/RDM pass-through supporting bi- directionalcom munications for discovery, addressing and DMX control of Philips Vaya products. This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6 X 32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Key Features 1:6-way DMX/RDM Splitter / Booster, Isolated DMX/RDM Input/Outputs ,RDM mode Surface or DIN-rail mountable& AC adaptor included.
122Supply and fixing of Single DMX ports control up to 340 light addresses, Works as a stand-alone or com-puter-driven controller, - Secure Digital (SD) card drive for flexible show storage - USB 2.0 interface for download-ing shows and configuring from attached PC or Mac :Simple installation and wiring is required - Flexible, adaptable mounting options are expected - Should be provided with light show authoring software - Direct line voltage power sup-ports 100 — 240 VAC - Six configurable effects by push buttons on player — Using light show authoring software to select from six effects, adjust effect settings such as color, speed, and brightness.
123Supply , Installation and testing of Panel 15 KVA 3 Phase & Servo MCB 6-32 amp 12 pcs , 32 amp TPN 10 KA 1 pcs
124Installation of GEL EARTHING with GI Strip to earthing along with existing cable
125Supply and Laying of PVC pipe 25 MM
126Supply and Laying of PVC pipe 32 MM
127Supply and laying with 32 MM GI pipe ISI
128Supply and laying 10 * 4 Core armoured aluminium cable
129Supply and fixing IP 65 boxes
130HAMIRPUR ENTRY POINTSurface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
131Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) 400 mm dia piles(2767.00)(.735X112/110)=2070.72
132Bentonite(3050.00)(.735X112/110)=2282.51
133Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.(3551.30)(.735X112/110)=2657.63
134Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 30 m and for all lift, as directed by Engineer in-charge. All kinds of soil
135Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
136Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.(494.10)(.735X112/110)=369.77
137Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
138Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
139Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete all work up to plinth level work; Concrete of M25 grade with minimum cement content of 330 kg /cum excluding the cost of centering and shuttering
140Reinforced cement concrete work in beams, columns suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
141Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete.
142Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc.
143Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
144Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers.
145Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).(515.60)(.735X112/110)=385.86
146Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift
147Brick work with common burnt clay F.P.S. (non modular) bricks of class-7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
148Brick work with common burnt clay F.P.S. (non modular) bricks of class-7.5 in superstructure above plinth up to floor V level in: Cement mortar 1:4 (1 cement : 4 coarse sand)
149Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:3 (1 cement :3 coarse sand)
15012 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
15115 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand)
152Extra for plastering done on moulding, cornices or architraves including neat finish to line and level: In one coat(713.20)(.735X112/110)=533.73
153Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
154Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
155Granite stone slab of colour black, Cherry/Ruby red : Area of slab upto 0.50 sqm
156Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).(769.6)(.735X112/110)=575.94
157CNC work - Engineered stone/natural stone/metal/ engineered metal /composite materials Sculpture work cladded in pillar, beam, dome, statues, etc. The manufacturing and installation to be done in following steps: (1) Preparation of initial models in white clay according to the pictures photo and their approval by department/Architect/Engineer (2) Construction of model on top of clay models with plaster of paris (3) Die casting the plaster of paris model (4) Finishing the models with sand paper and applying duco putty and finishing again to get real life effects. (5) Coloring the models with good quality spray applied oil colours. (6) Packing wrapped in bubble and transported safely to the site and installed on firm concrete base at the designated location
158Add for Elevational work of left out & other oramental work (moulding work on column and water flow cove ornamental work )
159Lettering & signage works including preparation & fixing plaque for branding of the departmet
160Supply, fabrication, transportation and installation of a complete 7-metre high Wave of Freedom artifact system consisting of a polygonal/continuously tapered Metal / GFRC / Engineered stone with base plate, foundation bolts, internal conduit provision, hoisting mechanism, stainless-steel elements and all required accessories; non-shrink grouting; erection of the system using crane and proper safety measures with full alignment and verticality checks; and all labour, materials, tools, machinery, transport, loading/unloading and incidental works included, complete in all respects as per approved drawings and specifications and direction of Engineer incharge,
161Supply, fabrication, transportation and installation of CNC cut Ashoka Chakra made with metal/Engineered metal / cotton metal Artifact having CNC cut blades inside the perimeter, visuals complete including provision of integrated lightning conduite / cove system consisting of base plate, foundation bolts, hoisting mechanism, and all required accessories; non-shrink grouting; erection of the system using crane and proper safety measures with full alignment and verticality checks; and all labour, materials, tools, machinery, transport, loading/unloading and incidental works included, complete in all respects as per approved drawings and specifications and direction of Engineer incharge,
162Providing, supplying, installing, testing and commissioning of complete integrated landscaping works including site clearance, excavation, leveling, soil bed preparation with minimum 300 mm thick fertile top soil mixed with organic manure, plantation of approved shrubs, hedges, ornamental plants, ground covers, turfing with natural grass and small decorative trees, edge treatment with stone / precast kerbs and all labour, materials, scaffolding, tools, transportation and incidentals complete as per approved drawings, specifications and directions ofEngineer-in-Charge
163Supply , Installation, Testing & Commissining of Exterior IP66 LED 2700/3000k with SS grill protection for vandal proof ,Neon Flexible light strip of 5 mtr standard length with 11 Watt per meter which can be compatible with the DMX / Ethernet controller. Minimum System lumens of minimum 1150 lumens/meter and System Lumen Efficacy > 82lm/w. Luminaire light beam spread - 110°, The Strip should have IP 66 protection and is offered IP 67 rated connector to join the LED Strips incontinuity. The luminaire must be offered with Aluminum channel for mounting the strip lights. The product should be complete with all accessories and Driver. The successful bidder shall submit the following certifications/reports for approval before SITC of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables.
164Supply , Installation, Testing & Commissining of Circular shape architectural RGBW (W=4000K) with SS grill protection for vandal proof LED flood light with integral driver & housing made of Die-cast aluminium alloy - ADC12. The luminaire shall be no bigger than Ø 225 X 162 without bracket. The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°. The bracket shall have locking mechanism to fix & secure the desired tilt angle. The luminaire shall have silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. The luminaire must have a breather gland. The nominal weight of the luminaire shall be 6KG. The luminaire shall be equipped with high- power Cree, osram, lumiled or equivalent. The fixture shall have 15° beam angle (±10%) & the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage not exceeding 50W and system lumen output of not less than 2230 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have an integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall give feedback on luminaire address & status (ON & Off).
165Supply , Installation, Testing & Commissining of Circular shape DOT luminaire ,with SS grill protection for vandal proof ,diirect view RGBNW max power 9 watts , min 290 lumens,32 lumens/watt with polycarbonate bowl , beam spread 160 degree, 24v DC and .9 power factor housing made of Die cast aluminium IP 66 & IK 06.The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand- held addressing device. The luminaire shall give feedback on luminaire address & status (ON & Off). The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. The luminaire shall be capable of digital dimming of 65536 steps. The successful bidder shall submit the following certifications/reports for approval before SITC of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables
166Supply and Fixing of RDM-6 Wall DMX Splitter & Booster is a 6- output DMX/RDM splitter with DMX/RDM pass-through supporting bi- directionalcom munications for discovery, addressing and DMX control of Philips Vaya products. This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6 X 32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Key Features 1:6-way DMX/RDM Splitter / Booster, Isolated DMX/RDM Input/Outputs ,RDM mode Surface or DIN-rail mountable& AC adaptor included.
167Supply and fixing of Single DMX ports control up to 340 light addresses, Works as a stand-alone or com-puter-driven controller, - Secure Digital (SD) card drive for flexible show storage - USB 2.0 interface for download-ing shows and configuring from attached PC or Mac :Simple installation and wiring is required - Flexible, adaptable mounting options are expected - Should be provided with light show authoring software - Direct line voltage power sup-ports 100 — 240 VAC - Six configurable effects by push buttons on player — Using light show authoring software to select from six effects, adjust effect settings such as color, speed, and brightness.
168Supply , Installation and testing of Panel 15 KVA 3 Phase & Servo MCB 6-32 amp 12 pcs , 32 amp TPN 10 KA 1 pcs
169Installation of GEL EARTHING with GI Strip to earthing along with existing cable
170Supply and Laying of PVC pipe 25 MM
171Supply and Laying of PVC pipe 32 MM
172Supply and laying with 32 MM GI pipe ISI
173Supply and laying 10 * 4 Core armoured aluminium cable
174Supply and fixing IP 65 boxes
175ROOMA ENTRY POINTSurface dressing of the ground including removing vegetation and in-equalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
176Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) 400 mm dia piles(2767.00)(.735X112/110)=2070.72
177Bentonite(3050.00)(.735X112/110)=2282.51
178Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.(3551.30)(.735X112/110)=2657.63
179Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 30 m and for all lift, as directed by Engineer in-charge. All kinds of soil
180Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
181Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge.(494.10)(.735X112/110)=369.77
182Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
183Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated bars of grade Fe-500D or more.
184Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete all work up to plinth level work; Concrete of M25 grade with minimum cement content of 330 kg /cum excluding the cost of centering and shuttering
185Reinforced cement concrete work in beams, columns suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
186Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete.
187Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc.
188Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts
189Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers.
190Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment).(515.60)(.735X112/110)=385.86
191Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lift
192Brick work with common burnt clay F.P.S. (non modular) bricks of class-7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
193Brick work with common burnt clay F.P.S. (non modular) bricks of class-7.5 in superstructure above plinth up to floor V level in: Cement mortar 1:4 (1 cement : 4 coarse sand)
194Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes (206.35)(.735X112/110)=154.42
19512 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
19615 mm cement plaster on rough side of single or half brick wall of mix:1:4 (1 cement: 4 coarse sand)
197Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
198Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
199Granite stone slab of colour black, Cherry/Ruby red : Area of slab upto 0.50 sqm
200Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).(769.6)(.735X112/110)=575.94
201CNC work - Engineered stone /metal / cotton metal composite vertical wall truss panels fixed / bolted / welded on foundation bolts etc. The wall vertical trussed to be fabricated and installation to be done in following steps: (1) Fixinging of partialy carved vertical metal members incuding fixing of foundation bolts as per approved drawings department/Architect/Engineer (2) Fabrication and instalation of support bracings in position by welding/bolting etc complete (3) instalation on CNC carved metal models / artifacts / symbols / specifics etc by welding, fastners, studs as per approved drawings etc complete (4) Buffing / polishing / finishing of installed CNC carved metal art works to get real life effects.
202Add for Elevational CNC stone art work on coping, other oramental work (moulding work on column and edges, bases ornamental work )
203Lettering & signage works including preparation & fixing plaque for branding of the city identity
204Providing, supplying, installing, testing and commissioning of complete integrated landscaping works including site clearance, excavation, leveling, soil bed preparation with minimum 300 mm thick fertile top soil mixed with organic manure, plantation of approved shrubs, hedges, ornamental plants, ground covers, turfing with natural grass and small decorative trees, edge treatment with stone / precast kerbs and all labour, materials, scaffolding, tools, transportation and incidentals complete as per approved drawings, specifications and directions ofEngineer-in-Charge
205Supply , Installation, Testing & Commissining of Exterior IP66 LED 2700/3000k with SS grill protection for vandal proof ,Neon Flexible light strip of 5 mtr standard length with 11 Watt per meter which can be compatible with the DMX / Ethernet controller. Minimum System lumens of minimum 1150 lumens/meter and System Lumen Efficacy > 82lm/w. Luminaire light beam spread - 110°, The Strip should have IP 66 protection and is offered IP 67 rated connector to join the LED Strips incontinuity. The luminaire must be offered with Aluminum channel for mounting the strip lights. The product should be complete with all accessories and Driver. The successful bidder shall submit the following certifications/reports for approval before SITC of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables.
206Supply , Installation, Testing & Commissining of Circular shape architectural RGBW (W=4000K) with SS grill protection for vandal proof LED flood light with integral driver & housing made of Die-cast aluminium alloy - ADC12. The luminaire shall be no bigger than Ø 225 X 162 without bracket. The luminaire shall have electrostatically applied polyester powder coating finish. The luminaire bracket shall be made of cold-rolled steel & shall be so designed that the luminaire can be tilted to ±90°. The bracket shall have locking mechanism to fix & secure the desired tilt angle. The luminaire shall have silicon gasket between optical cover & LED chamber to ensure proper IP66 protection. The luminaire must have a breather gland. The nominal weight of the luminaire shall be 6KG. The luminaire shall be equipped with high- power Cree, osram, lumiled or equivalent. The fixture shall have 15° beam angle (±10%) & the lens shall be made of anti-aging & anti UV-PMMA material. The optical cover shall be made of IK06 rated clear tempered glass. The LEDs shall have minimum CRI ≥80 for white light & shall have SDCM≤4. The fixture shall come with power & DMX cable of minimum 100mm length. The fixtures shall be installed with have IP67 connectors. The luminaire shall have system wattage not exceeding 50W and system lumen output of not less than 2230 lumens. Fixture shall operating temperature range of -40°C to 50°C. The fixture shall have an integral driver with input voltage for 220-240 VAC, 50/60Hz. The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand-held addressing device. The luminaire shall give feedback on luminaire address & status (ON & Off).
207Supply , Installation, Testing & Commissining of Circular shape DOT luminaire ,with SS grill protection for vandal proof ,diirect view RGBNW max power 9 watts , min 290 lumens,32 lumens/watt with polycarbonate bowl , beam spread 160 degree, 24v DC and .9 power factor housing made of Die cast aluminium IP 66 & IK 06.The luminaire shall have declared life of 50,000 burning hours at L70 @ 35deg. The luminaire shall have class I insulation. The luminaire shall be compatible with DMX512 controller. The luminaire shall automatically addressable using hand- held addressing device. The luminaire shall give feedback on luminaire address & status (ON & Off). The luminaire shall be capable of 8-bit control of RED, Green, Blue & White (W=4000K) to produce 16.7million colours. The luminaire shall be capable of digital dimming of 65536 steps. The successful bidder shall submit the following certifications/reports for approval before SITC of materials: product data sheets, LM79 report from NABL accredited lab, illuminance diagram, polar curve & LM80 report issued by LED manufacturer & RoHS Compliance alone with CE certificate. The bidder shall upload the luminaire BIS certificate along with technical bid. The luminaire shall be supplied with necessary connectors for connecting lead/jump cables
208Supply and Fixing of RDM-6 Wall DMX Splitter & Booster is a 6- output DMX/RDM splitter with DMX/RDM pass-through supporting bi- directionalcom munications for discovery, addressing and DMX control of Philips Vaya products. This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6 X 32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Key Features 1:6-way DMX/RDM Splitter / Booster, Isolated DMX/RDM Input/Outputs ,RDM mode Surface or DIN-rail mountable& AC adaptor included.
209Supply and fixing of Single DMX ports control up to 340 light addresses, Works as a stand-alone or com-puter-driven controller, - Secure Digital (SD) card drive for flexible show storage - USB 2.0 interface for download-ing shows and configuring from attached PC or Mac :Simple installation and wiring is required - Flexible, adaptable mounting options are expected - Should be provided with light show authoring software - Direct line voltage power sup-ports 100 — 240 VAC - Six configurable effects by push buttons on player — Using light show authoring software to select from six effects, adjust effect settings such as color, speed, and brightness.
210Supply , Installation and testing of Panel 15 KVA 3 Phase & Servo MCB 6-32 amp 12 pcs , 32 amp TPN 10 KA 1 pcs
211Installation of GEL EARTHING with GI Strip to earthing along with existing cable
212Supply and Laying of PVC pipe 25 MM
213Supply and Laying of PVC pipe 32 MM
214Supply and laying with 32 MM GI pipe ISI
215Supply and laying 10 * 4 Core armoured aluminium cable
216Supply and fixing IP 65 boxes
217O & M for Two Years @ 3.00% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56923887
AUTHORITY Government Departments
TENDER VALUE 19.81 Crore
LAST DATE 25-08-2026
Authority
Authority Name Kanpur Municipal Corporation
Work Description Tender for Construction Of City Entrance Gateways Of Kanpur City.
Basic Detail
Tender No ENTRYGATES/26-27
Bidding Type Tender
Location
City Kanpur
State Uttar Pradesh
Key Dates
Publish Date 14 Aug 2026
Submission Date 25 Aug 2026
Open Date 01 Jan 0001
Finance
Tender Value 19.81 Crore
Tender Fee 25738
EMD 1.01 Crore
Exemption Not Available
Document List
9c0e4c18-1a0d-4036-b778-cc51a6e045a5.html
BOQ_2209388.xls
RFPSelectionofAgencyforDe_1.pdf
Tendernotice_1 (32).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 14, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 25, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Aug 25, 2026
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Aug 25, 2026
18:00 IST

Corrigendum-3 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 1 day
Aug 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day

Tender Documents

Download All (ZIP) ↓
html

9c0e4c18-1a0d-4036-b778-cc51a6e045a5.html

xls

BOQ_2209388.xls

pdf

RFPSelectionofAgencyforDe_1.pdf

pdf

Tendernotice_1 (32).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders