Tender For Electrical Renovation Work Including Supplying & Fixing Of Main Switch, Db Boxes, Indoor And Outdoor Illumination System Etc. At Dhosa Rest Shed Under Mograhat Drainage Division, District: South 24 Pgns. Under The Jurisdiction Of Metropoli
Tender Overview
Project Description
Tender for Electrical Renovation Work Including Supplying & Fixing Of Main Switch, Db Boxes, Indoor And Outdoor Illumination System Etc. At Dhosa Rest Shed Under Mograhat Drainage Division, District: South 24 Pgns. Under The Jurisdiction Of Metropolitan Electrical Division.
BOQ
| Sl. No. | Item Description |
| 1 | Distribution wiring in 1.1KV grade 2x22/0.3 (1.5 sqmm) single core straded \\"FR\\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in sutable size PVC casing-capping (Precision make) with 1x22/0.30 (1.5 sq mm) single core standard FR PVC insulated and unsheathed copper wire for ECC incl. necessary fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI/PVC switch board with top cover plate on wall incl. mending good damages to original finish [only PVC casing-capping and switch board both on surface] |
| 2 | Average run 5 mtr |
| 3 | Distribution wiring in 1.1KV grade 2x22/0.3 (1.5 sqmm) single core stranded \\"FR\\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in sutable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5sqmm) single core straded \\"FR\\" PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S&F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI/PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface.] |
| 4 | On Board |
| 5 | Distribution wiring in 1.1KV grade single core stranded FR PVC insulated and unsheathed copper wire (brand approved by EIC) of following sizes in 25mm PVC casing capping (Precision make) including necessary PVC clips fittings etc. |
| 6 | 2x22/0.3(1.5sqmm) + 1x22/0.3(1.5sqmm) |
| 7 | 2x36/0.3(2.5sqmm) + 1x22/0.3(1.5sqmm) |
| 8 | 2 x 56 / 0.3 (4 sqmm) + 1 x 36 /0.3 ( 2.5 sqmm) |
| 9 | Supplying and drawing 1.1 KV single core standard FR PVC insulated and unsheathed single core stranded cu wire (Brand approvd. By EIC) of the following sizes in the pre laid polythene pipe and by the pre laid GI fish wire and making necy. connection as required. |
| 10 | 4x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC |
| 11 | SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR ARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS. |
| 12 | 6 Sqmm 2 Core Al Cable |
| 13 | Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting. |
| 14 | Laying of one no. Cable upto 35sqmm in underground trench 460mm width and 760 mm depth with brick protection on the top of the cable with 8 (eight) nos. Bricks per metre including filling the space between the brick and cable and also the trench with sifted soil levelling up and restoring surface duly rammed. |
| 15 | Laying of cable 2.5 sqmm to 35sq mm at an average depth 75mm in floor/pavement/wall and making holes including embedding the cable at an average depth and mending good damages to original finish including removing the rubbish. |
| 16 | From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc. |
| 17 | Supplying of approved make high speed ceiling fan (ISI marked) of following sizes having double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts |
| 18 | 1200 mm |
| 19 | Supply TMC501 Conventional industrial batten Philips LEDtube, model no : TMC 501 P 1xT-LED 22W P3241 with 1no Mas LEDtube 1200mm 18W865 T8 I – 2100lm including necessary connection. |
| 20 | Supply TMC501 Conventional industrial batten Philips LEDtube, model no : TMC 501 P 2xT-LED 22W P3242 with 2nos Mas LEDtube 1200mm 18W865 T8 I – 2100lm including necessary connection. |
| 21 | Supplying of approved make wall fan oscillating type with base, blades, guard, speed regulator etc. AC 230- 250 volts. |
| 22 | 400 mm sweep |
| 23 | Excavation of soil for installation of earth electrode and filling & ramming |
| 24 | For soft soil |
| 25 | Earthing with 50mm dia G.I. Pipe 3.64 mm thick x 3.04 long and 1 x 4 SWG G.I. Wire (4 mts long), 13 mm dia, 80mm long G.I. Boilts, nuts, including S&F 15mm dia G.I. Pipe protection incl. Excavation of soil for installation of Earth electrode for filling and ramming etc. complete |
| 26 | Supplying and fixing compression type gland complete with brass gland, brass rings & rubber ring for dust and moisture proof entry of XPLE/P.V.C. Armoured Aluminium cable |
| 27 | 2 core 6 sqmm Al cable |
| 28 | Finishing the end of following XLPE/PVC armoured cable by crimping method including supply and fixing solderless sockets. (Dowells make) , tapes anti-currosive paste and jointing materials |
| 29 | 2 core 6 sqmm Al cable |
| 30 | Supplying& fixing medium gauge GI Pipe (ISI-Medium) Protection with necessary fittings and jointing materials as required. |
| 31 | 25mm dia |
| 32 | Supplying and fixing Sheet steel Main Switches on angle iron frame on wall |
| 33 | 63A, standard 415V TPN with fuse on L&N |
| 34 | Supplying & fixing double door horizontal TPN MCB Distribution board with 1 P-42/43 protection concealed in wall after cutting the wall and mending good the damages to original finish incl. Inter-connection with suitable size of copper wire and neutral link & provision for earthing attachment. |
| 35 | 8 Way Enclosure (8GB 32202RC08) (Siemens make) |
| 36 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall and making good the damages to original finish incl. painting, connection & provision for earthing attachment. |
| 37 | 4 way |
| 38 | Supply & fixing 240/415V MCB of Breaking capacity 10 KA & C characteristics on din rail of existing DBS and necessary connection |
| 39 | Siemens make 6-32A-SP |
| 40 | Siemens make 32A FP |
| 41 | Siemens make 63A-FP |
| 42 | Connection the equipments to earth busbar including S&F GI (Hot Dip) wire of size as below on wall/floor with stables buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. As required and mending good damages. Solid GI wire |
| 43 | No. 8 SWG |
| 44 | Supplying & fixing 240 V AC/DC superior type Dingdong call bell (Anchor) on SW Board including S&F HW board. |
| 45 | Supplying of different types of LED lamps |
| 46 | Havells make, NU Bulb Plus 9 W 865 B22 3 Star |
| 47 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint |
| 48 | Supply and fixing of smart bright essential street light (70 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc. |
| 49 | Make : Philips, 68 watt |
| 50 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making attachment, painting and mending good damages to building works |
| 51 | 2 module |
| 52 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with 3 nos. suitable size copper bar with holes for phase neutral & earth fixed on bakelite/hard rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works |
| 53 | 4 module |
| 54 | 6 module |
| 55 | 8 module |
| 56 | 12 Module |
| 57 | Supply & fixing 240V, 6A, 3 pin Modular type switch (Brand approved by EIC), on existing GI Modular type switch board having top cover plate and making necessary connections as required . |
| 58 | Supply & fixing 240V, 16A, Piano key type switch (Brand approved by EIC), on GI Modular type switch board having top cover plate and making necessary connections as required . |
| 59 | Supply & fixing 240V, 16A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necessary connections with PVC Cu wie and earth continuity wire etc. |
| 60 | Supply & fixing 240V , 6A 5 pin modular type plug socket (Brand approved by EIC) without switch & plug top on existing GI modular tupe switch board with top cover plate and making necy. Connections with PVC Cu wire and earth continuity wire etc. |
| 61 | Supply & fixng 240V, Modular Socket ( 2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. Making necy.connections etc. |
| 62 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 63 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug top with indicator (brand approved by EIC) and necy. Connections. |
| 64 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 65 | Supply & fixing 240V,25A, 3 pin modular type plug socket (Brand approvd. by EIC, without plug top abd switch, on existing GI modular type switch board with top cover plate and making necy. Connections with PVC Cu wire and earth continuity wire etc. |
| 66 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required |
| 67 | 80mm dia |
| 68 | 65mm dia |
| 69 | Erection of single steel tubular pole of length as give below with/without sole plate & cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600cx150mm thick CC (4:2:1) base black below sole plate/pole with hard jhama metal including CC (6:3:!) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6km from store to work site including filling up the excavated earth pit with shifted soil and ramming properly. |
| 70 | Upto 9.0 mtr.size 0.6x0.6x1.70 mts |
| 71 | Supply and fixing of GreenLED Ultima Square (6\\" x 6\\") , incl cutting the false ceiling in reqd dimensions also the wiring and connection of the light by 1.5 sq mm cu wire complete. |
| 72 | Make : Havells, 18 watt square/ round |
| 73 | Supplying & fixing earth busbar of galvanised (hot dip) MS flat 25mm x 6mm on wall having clearance of 6mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts spacing insulators etc. as required. |
| 74 | Dismantling old wiring, service connection and welding of GI tube and baseplate etc. |
| 75 | Electrician 1 no x 1 day |
| 76 | Helper 1 no x 1 day Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender