Tender For Illumination Of C Us Area Including Internal Distribution Wiring Of Newly Constructed Extended Rooms Including S & F Of Lights/ Fans Etc. At Jharkhali Inspection Bungalow, In Block : Basanti, Ps: Jharkhali, Dist : South 24 Parganas Under T
Tender Overview
Project Description
Tender for Illumination Of C Us Area Including Internal Distribution Wiring Of Newly Constructed Extended Rooms Including S & F Of Lights/ Fans Etc. At Jharkhali Inspection Bungalow, In Block : Basanti, Ps: Jharkhali, Dist : South 24 Parganas Under The Jurisdiction Of Metropolitan Electrical Division.
BOQ
| Sl. No. | Item Description |
| 1 | Supplying swaged and welded steel tubular pole of following specifications as per IS 2317: 1980)7m length, 85Kg, 410-SP-03 |
| 2 | Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly.Upto 9.0 mtr. Size 0.6x0.6x1.70 mts |
| 3 | Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cmx25cmx10cm GI Loop box, 16SWG & incl. drilled hole in pole. |
| 4 | Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paintUpto 9.0 mtr. long pole |
| 5 | One coat of red lead/Zinc chromate priming |
| 6 | 1st coat of synthetic enamel paint over the primer |
| 7 | 2nd coat of synthetic enamel paint over the 1st coat |
| 8 | Supplying and Fixing Sintex made water proof looping cable box of the following sizes as indicated below, Comprising of one 250 V, 6 A SP MCB unit, one NL on porcelain insulator incl. One(01) no 4 pole terminal connector etc. incl Internal Connection and housing the same above the muffing by suitable pole clamps etc completeSize of box : 250 x 200 x105 GSJB |
| 9 | Supply and fixing of smart bright street light (36 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.Make : Crompton, 36 watt |
| 10 | SITC of GI Earthing spike of size 1833 MM x 20 mm including inserting at required depth and connection by supplying and fixing GI (Hot dip) strip 20mm x 3 mm thick from earth spike to pole (2.5 Mtr distance from earth spike connection point to pole) complete in all respect as per direction of the EIC. |
| 11 | SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR ARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS. |
| 12 | 2 Core 10 sq mm |
| 13 | 4 Core 35 sq mm |
| 14 | Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed. |
| 15 | Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : |
| 16 | For 2 core upto 10 sqmm |
| 17 | For 4 core upto 35 sqmm |
| 18 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : |
| 19 | 2 core 10 sqmm cable |
| 20 | 3.5 core 35 sqmm cable |
| 21 | Supplying and drawing PVC Insulated and PVC sheathed multicore 1.5 Sq.mm (3 Core) cable with electrolytic grade annealed copper conductor suitable upto 1100 grade through inside the pole from loop box to fittings. |
| 22 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.Legrand, 2+8 Way, Enclosure (607711) |
| 23 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.Legrand 40A DP |
| 24 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.Legrand 6-32A SP |
| 25 | Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction)19mm dia 3mm thick Polythene Pipe |
| 26 | Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required. |
| 27 | 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC |
| 28 | Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc. |
| 29 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) |
| 30 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) |
| 31 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casingcapping and Switch board both on surface]Average run 5 mtr |
| 32 | Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI / PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface]On Board |
| 33 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.6 Module |
| 34 | Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required. |
| 35 | Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required. |
| 36 | Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 37 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 38 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 39 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. |
| 40 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 41 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc. |
| 42 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 43 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 23 cm (9\\") |
| 44 | Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required. |
| 45 | Supply TMC501 Conventional industrial batten Philips LEDtube, model no : TMC 501 P 1xT-LED 22W P3241 with 1no Mas LEDtube 1200mm 18W865 T8 I – 2100lm including necessary connection. |
| 46 | Supply TMC501 Conventional industrial batten Philips LEDtube, model no : TMC 501 P 2xT-LED 22W P3242 with 2nos Mas LEDtube 1200mm 18W865 T8 I – 2100lm including necessary connection. |
| 47 | Supply and fixing of philips Smartbrite Xtra 2ft run length LED Batten Tube light, 12 watt incl Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length |
| 48 | Supplying of approved make high speed ceiling fan (ISI marked) of following sizes having double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts 1200 mm sweep |
| 49 | Supplying of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250.225mm sweep RPM 900 / 1400 (9\\") |
| 50 | Supply and Installationof Split type room air conditioning machine of following tonnage capacity 3 star rating fitted with rotary crompresser and cooling capacity min. 6000 k cal/Hr., minimum discharge air flow 800cum mtr, 800EER ( W/W) 2.7-2.89. (Rates are inclusive of extra refrigerant pipe drain pipe connecting cable) up to the satisfaction of the EIC.1.5 Ton (Make : Voltas) 3 star non-inverter type |
| 51 | Supply and fixing of philips Sleek Surface Downlight, 16 watt WH, after cutting the ceiling or wall as reqd. and also mending good the damages to building works incl wiring and connection of the light by 1.5 sq mm cu wire complete. |
| 52 | Supplying of approved make Pedestal fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts.500mm sweep |
| 53 | Supplying of different types of LED lampsMake : Philips, 9.0 Watt, Base B22/ E27, 825 Lm |
| 54 | Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991)4 bars, 415 V, 100/125 A Dimension of Al. bars [85mm long] 4 x 25x5mmDimension of Sheet Metal Box 500x150mm |
| 55 | Supply delivery testing and commissioning of 24V UPS system for backup for light fittings, fans, power points etc. at Gosaba Irr. Bunglow as per direction of EIC (With two nos 12V, 150AH Exide make INVAMASTER battery) |
| 56 | Supplying and fixing of voltage stabilizer for 1.5Tr AC (130-300V) with suitable arrangement as required for air condition machine make : Microtek or V-guard at different sites. |
| 57 | Supply and fixing of smart bright essential street light (70 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.Make : Panasonic, 70 watt (at Canning, Gosaba and Basanti) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 9 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender