Water Resources and Irrigation Government Departments Closing in 9 days TDR #56923514

Tender For Illumination Of C Us Area Including Internal Distribution Wiring Of Newly Constructed Extended Rooms Including S & F Of Lights/ Fans Etc. At Jharkhali Inspection Bungalow, In Block : Basanti, Ps: Jharkhali, Dist : South 24 Parganas Under T

Issued by Government Departments · 24 Paraganas South, West Bengal
Tender Value
13.75 Lakhs
Estimated cost
Bid Submission
24 Aug 2026
9 days left
EMD
27507
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
24 Paraganas South → West Bengal
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Illumination Of C Us Area Including Internal Distribution Wiring Of Newly Constructed Extended Rooms Including S & F Of Lights/ Fans Etc. At Jharkhali Inspection Bungalow, In Block : Basanti, Ps: Jharkhali, Dist : South 24 Parganas Under The Jurisdiction Of Metropolitan Electrical Division.

BOQ

Name of Work:- Illumination of c us area including internal distribution wiring of newly constructed extended rooms including S & F of lights/ fans etc. at Jharkhali Inspection Bungalow, in Block : Basanti, PS: Jharkhali, Dist : South 24 Parganas under the jurisdiction of Metropolitan Electrical Division.
Sl. No. Item Description
1Supplying swaged and welded steel tubular pole of following specifications as per IS 2317: 1980)7m length, 85Kg, 410-SP-03
2Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly.Upto 9.0 mtr. Size 0.6x0.6x1.70 mts
3Extra on items 1& 2 above, for providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. S & F 25cmx25cmx10cm GI Loop box, 16SWG & incl. drilled hole in pole.
4Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paintUpto 9.0 mtr. long pole
5One coat of red lead/Zinc chromate priming
61st coat of synthetic enamel paint over the primer
72nd coat of synthetic enamel paint over the 1st coat
8Supplying and Fixing Sintex made water proof looping cable box of the following sizes as indicated below, Comprising of one 250 V, 6 A SP MCB unit, one NL on porcelain insulator incl. One(01) no 4 pole terminal connector etc. incl Internal Connection and housing the same above the muffing by suitable pole clamps etc completeSize of box : 250 x 200 x105 GSJB
9Supply and fixing of smart bright street light (36 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.Make : Crompton, 36 watt
10SITC of GI Earthing spike of size 1833 MM x 20 mm including inserting at required depth and connection by supplying and fixing GI (Hot dip) strip 20mm x 3 mm thick from earth spike to pole (2.5 Mtr distance from earth spike connection point to pole) complete in all respect as per direction of the EIC.
11SUPPLYING OF FOLLOWING XLPE INSULATED ALUMINUM CONDUCTOR ARMORED CABLES OF 1.1KV GRADE AS PER IS 7098 (PART 1) 1988 WITH UP TO DATE AMENDMENTS.
122 Core 10 sq mm
134 Core 35 sq mm
14Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
15Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :
16For 2 core upto 10 sqmm
17For 4 core upto 35 sqmm
18Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
192 core 10 sqmm cable
203.5 core 35 sqmm cable
21Supplying and drawing PVC Insulated and PVC sheathed multicore 1.5 Sq.mm (3 Core) cable with electrolytic grade annealed copper conductor suitable upto 1100 grade through inside the pole from loop box to fittings.
22Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.Legrand, 2+8 Way, Enclosure (607711)
23Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.Legrand 40A DP
24Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.Legrand 6-32A SP
25Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction)19mm dia 3mm thick Polythene Pipe
26Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.
272x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
28Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.
292 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)
302 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm)
31Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. to light/fan/call bell point with Modular type switch (Brand approved by EIC) fixed on Modular GI / PVC switch board with top cover plate on wall incl. mending good damages to original finish. [PVC casingcapping and Switch board both on surface]Average run 5 mtr
32Distribution Wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. with S & F 6A 5 pin Modular type plug socket and switch (Brand approved by EIC) fixed on 4 Module GI / PVC switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works [PVC casing-capping and plug box both on surface]On Board
33Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works.6 Module
34Supply & Fixing 240 V 6 A Modular type switch (Brand approved by EIC) on existing GI Modular type switch board having top cover plate and making necessary connections as required.
35Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required.
36Supply & Fixing 240 V, 6A, 5 pin Modular type plug socket (Brand approved by EIC), without switch & plug top, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
37Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
38Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
39Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections.
40Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
41Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc.
42Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
43Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 23 cm (9\\")
44Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required.
45Supply TMC501 Conventional industrial batten Philips LEDtube, model no : TMC 501 P 1xT-LED 22W P3241 with 1no Mas LEDtube 1200mm 18W865 T8 I – 2100lm including necessary connection.
46Supply TMC501 Conventional industrial batten Philips LEDtube, model no : TMC 501 P 2xT-LED 22W P3242 with 2nos Mas LEDtube 1200mm 18W865 T8 I – 2100lm including necessary connection.
47Supply and fixing of philips Smartbrite Xtra 2ft run length LED Batten Tube light, 12 watt incl Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10 mt. length
48Supplying of approved make high speed ceiling fan (ISI marked) of following sizes having double ball bearing complete with standard down rod, canopy, hanging shackle, Aluminium blades, without regulator, A.C. 230-250 volts 1200 mm sweep
49Supplying of approved make exhaust fan heavy duty with mounting frame, blades AC 230-250.225mm sweep RPM 900 / 1400 (9\\")
50Supply and Installationof Split type room air conditioning machine of following tonnage capacity 3 star rating fitted with rotary crompresser and cooling capacity min. 6000 k cal/Hr., minimum discharge air flow 800cum mtr, 800EER ( W/W) 2.7-2.89. (Rates are inclusive of extra refrigerant pipe drain pipe connecting cable) up to the satisfaction of the EIC.1.5 Ton (Make : Voltas) 3 star non-inverter type
51Supply and fixing of philips Sleek Surface Downlight, 16 watt WH, after cutting the ceiling or wall as reqd. and also mending good the damages to building works incl wiring and connection of the light by 1.5 sq mm cu wire complete.
52Supplying of approved make Pedestal fan oscillating type with base, blades, guard, speed regulator etc. AC 230-250 volts.500mm sweep
53Supplying of different types of LED lampsMake : Philips, 9.0 Watt, Base B22/ E27, 825 Lm
54Supplying & fixing sheet metal (16 SWG) Iron Clad Busbar chambers on angle iron frame on wall, incl. earthing attachment and painting as required – (As per Drawing no. 470 of PWD Specification Book – May 1991)4 bars, 415 V, 100/125 A Dimension of Al. bars [85mm long] 4 x 25x5mmDimension of Sheet Metal Box 500x150mm
55Supply delivery testing and commissioning of 24V UPS system for backup for light fittings, fans, power points etc. at Gosaba Irr. Bunglow as per direction of EIC (With two nos 12V, 150AH Exide make INVAMASTER battery)
56Supplying and fixing of voltage stabilizer for 1.5Tr AC (130-300V) with suitable arrangement as required for air condition machine make : Microtek or V-guard at different sites.
57Supply and fixing of smart bright essential street light (70 Watt) complete with all accessories to be fixed /projected from the wall of the building or on pole incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.Make : Panasonic, 70 watt (at Canning, Gosaba and Basanti) Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56923514
AUTHORITY Government Departments
TENDER VALUE 13.75 Lakhs
LAST DATE 24-08-2026
Authority
Authority Name Irrigation And Waterways Department
Work Description Tender for Illumination Of C Us Area Including Internal Distribution Wiring Of Newly Constructed Extended Rooms Including S & F Of Lights/ Fans Etc. At Jharkhali Inspection Bungalow, In Block : Basanti, Ps: Jharkhali, Dist : South 24 Parganas Under The Jurisdiction Of Metropolitan Electrical Division.
Basic Detail
Tender No WBIW/EE/MED/e-NIT-15/2026-27
Bidding Type Tender
Location
City 24 Paraganas South
State West Bengal
Key Dates
Publish Date 08 Aug 2026
Submission Date 24 Aug 2026
Open Date 24 Aug 2026
Finance
Tender Value 13.75 Lakhs
Tender Fee Ref. Documents
EMD 27507
Exemption Not Available
Document List
19695e9f-e388-47fb-81d6-fa4d919e91b8.html
BOQ_2546245.xls
Tendernotice_1 (18).pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Aug 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

19695e9f-e388-47fb-81d6-fa4d919e91b8.html

xls

BOQ_2546245.xls

pdf

Tendernotice_1 (18).pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender