Public Administrative Department Local Bodies Closing in 1 days TDR #56916543

Short dated tender - Tender For annual rate contract Of R And M Work Of Led Street Lights, Timer And Ccms In Ward No. 43 To 65 In Nagar Nigam Area.

Issued by Local Bodies · Bharatpur, Rajasthan
Tender Value
1.29 Crore
Estimated cost
Bid Submission
12 Aug 2026
1 days left
EMD
2.58 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bharatpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available

Project Description

Short dated tender - Tender for annual rate contract Of R And M Work Of Led Street Lights, Timer And Ccms In Ward No. 43 To 65 In Nagar Nigam Area.

BOQ

Name of Work:- ARC of R and M work of LED street lights, Timer and ccms in ward No. 43 to 65 in nagar nigam area.
Sl. No. Item Description
1Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .1 X 25 sq. mm. + 1X25 sq. mm. (insulated)
2Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discom's specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSRSuspension clamp with eye hook & Pole clamp
3Dead end clamp with eye hook & Pole clamp
4Supply and fixing of LT porcelain shackle insulator as per IS:1443 1979 and as per Discom's standard specifications, suitable for working voltage 1100 volts including all accessories like GI Hardware fittings confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. 100mm x 110mm
5Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR16.0 Sq. mm; 4 core
625.0 Sq. mm; 3.5 core
7Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth
8Add Extra in Item no.60.5 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same
9P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .
10Labour charges for Dismantling of following existing street light electric poles with street light fixtures, underground cable, MS box and other electric items of the pole coming along the alignment of the road and removal and re- rolling MS poles/PCC poles of different sizes as well as handing over the same to DISCOM/UIT/MC store and as per the direction of Engineer Incharge and clean the site good as per the requirement and submit the receipt from concering authority, all complete works.
11Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .A) Excavation of Pit for Foundation Size upto required depth from Ground levelB) Dressing of Pit and Dry stone pitching 200 mm thick including supply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of 75 mm thicknessD) Reinforcement for R.C.C. work with TMT bars including straightening, cutting, bending, placing in position and binding all complete.E) Centring and shuttering including strutting , propping etc. and removal of form work for Footing and PedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe & Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-25 grade in Footing and Pedestal including Curing the foundation for 7 days.H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2 no. 100 mm long, 10 mm dia. Lugs on each face.Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr.
12Dismantling and re - fixing of porcelain shackle insulator as per IS:1443 1979 suitable for working on 1100 volts including hot dipped GI accessories and heavy duty hardwares etc as required as per Discom specification. 100mm x 110mm
13Labour cost for re-painting over the existing poles above ground level including overhang making surface well clean and apply two coats of aluminium/ enamel paint as approved with required T & P etc as required. Pole of 7 to 9 mtr longwith one overhang
14with two overhang
15Dismantling and re- fixing of cross arms as per Discom specification, made out from angle iron 50mmx 50mmx6mm having 'D' support for each insulator including all necessary nuts,bolts, holding clamp of 50x6mm flat etc as reqd. on existing pole or on wall and special accessories for XLPE insulated ABC overhead cable like I- hook, Dead End clamp assembly, Suspension clamp assembly as requiredSuspension clamp with eye hook (REC Standard) & pole clamp
16Dismantling and re - drawing of XLPE insulated LT bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required as per Discom specification.1 X 25 sq. mm. + 1X25 sq. mm. (insulated)
17Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 4 pole Power contactors with following AC 1 Rating ; 63 Amp
18Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR. Four pole MCB (With B/C curve tripping Characteristics); 50/63 A rating
19Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . One day & week reserve (Analog type )
20नगर निगम भरतपुर क्षेत्र वार्ड संख्या 43 से 65 में लगी में लगी 15-20/ 40/72/ 100-120 /200 वाट एव अन्य समस्त लाइटो मय टाइमर / CCMS सहित का रख-रखाव करना, फॉल्टों को दुरूस्त करना,खराब /डायरेक्ट लाईटो में पी वी सी वायर लगाना एव हाई मास्ट लाईट उतारना, चढाना, फॉल्टों को दुरूस्त करना, क्रोर्स आर्म पर गिरे हाफवायर को पुनः लगाना वाईड़िग करना, अन्य विधुत वायर/गार्ड वायर से उलझे हाफवायर को सही करना, वाईड़िग खुलने के कारण गिरे हाफवार को पुनः पोल पर लगाना वाईड़िग करना, टूटे पिन / साइकिल इन्सुलेटर पुनः पोल पर लगाना, टूटे हाफवायर के स्थान पर पुनः हाफवायर को लगाना आदि मय लेवर मय सामान सहित रख रखाव ,शहर की सार्वजनिक लाईट व्यवस्था सुचारू रखना ए स्ट्रीट लाइट्स को निर्धारित समय से on/off करना तथा phase wire का संधारण करना आदि एंव निविदा और 50 मीटर तक का फेज वायर डालना आदि कार्य जो निविदा की शर्तों से सम्बंधित है Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56916543
AUTHORITY Local Bodies
TENDER VALUE 1.29 Crore
LAST DATE 12-08-2026
Authority
Authority Name Department Of Local Bodies
Work Description Short dated tender - Tender for annual rate contract Of R And M Work Of Led Street Lights, Timer And Ccms In Ward No. 43 To 65 In Nagar Nigam Area.
Basic Detail
Tender No Nit (10033/2026-27 Light)
Bidding Type Tender
Location
City Bharatpur
State Rajasthan
Key Dates
Publish Date 08 Aug 2026
Submission Date 12 Aug 2026
Open Date 13 Aug 2026
Finance
Tender Value 1.29 Crore
Tender Fee 2000
EMD 2.58 Lakhs
Exemption Available
Document List
BOQ_1039007.xls
dd2e5807-d55e-4721-b647-d3884c5a09e2.html
Tendernotice_1 (33).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Aug 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1039007.xls

html

dd2e5807-d55e-4721-b647-d3884c5a09e2.html

pdf

Tendernotice_1 (33).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders