Water Resources and Irrigation Government Departments Closing in 15 days TDR #56915624

Tender For Construction Of Ghat And Astha Path On Left Bank Of Ganga River In Gaurishankar Area In Downstream Of Chandi Ghat In District Haridwar

Issued by Government Departments · Haridwar, Uttarakhand
Tender Value
80.15 Crore
Estimated cost
Bid Submission
27 Aug 2026
15 days left
EMD
1.05 Crore
Bank guarantee accepted
Document Fee
5900
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Haridwar → Uttarakhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Ghat And Astha Path On Left Bank Of Ganga River In Gaurishankar Area In Downstream Of Chandi Ghat In District Haridwar

BOQ

Name of Work:- Construction of Ghat and Astha Path on left bank of Ganga river in Gaurishankar area in downstream of Chandi Ghat in district Haridwar
Sl. No. Item Description
1Clearing and grubbing road land including uprooting wild vegetation, grass, Bushes, Shrubs, Saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical Specification Clause 201.
2Dewatering of water caused due to seepage of ground water and surface water due to rain etc. excluding excavation of foundation but during execution of civil works including supply of all machine operator, khalashi, POL, T&P, accessories required for proper completion of the work.
3Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 - P.C.C grade M 15 - Nominal mix (1:2.5:5)
4Providing concrete for plain/Reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 - P.C.C grade M 20
5Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (R.C.C. grade M 25)
6Supplying, fitting, and placing TMT bar reinforcement (Fe 415) in substructure complete as per drawing and technical specifications Clauses 1002,1005, 1010 and 1202
7Hand Packed stone filling in back of wallls including cost of all materials, royality, T&P etc. complete as per direction of Engineer-in- charge. (As per PWD Uttarakhand specifications)
840 mm thick fine dressed stone flooring over 20mm (average) thick Base of cement mortar 1:5 (1 cement : 5 coarse sand), including pointing with cement mortar 1:2 (1 cement : 2 stone dust) with an admixture of pigment to match the shade of stone.( Red sand stone ).
9Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist lab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
10Chainging Room
11Excavation for Structures Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
12Providing concrete for plain/reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3.6
13Brick masonry work in cement mortar in substructure complete excepting pointing and plastering, as per drawing and technical specification Clauses 602, 603, 604,1202 & 1204 In 1:4 Cement mortar
14Plastering with cement mortar (1:4), 15 mm thick on brickwork in substructure as sq.mper technical specification Clauses 613.4 & 1204
15Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 M20
16Supplying, fitting and placing HYSD bar reinforcement in foundation complete as per drawings and technical specifications Clauses 1000 and 1202
17New work (two or more coats) with a base coat of white washing with lime.
18Providing and Fixing factory made PVC door frame made of PVC extruded sections of size 75 mm x 53 mm, having wall thickness 2.0 mm (± 0.2 mm). Both verticalssides of the frame reinforced with PVC profile of cross section size 28 mm x 30 mm x 2 mm thickness (± 0.2 mm) and 75 mm x 200 mm long, including reinforcing both ends of the top frame with PVC profile. PVC Door Frame and PVC reinforcement profile to be mitred cut, jointed and fusion welded together, including providing and fixing 3 nos of 125 mm long stainless steel hinges to frame, fixing the frame with jamb with required nos & sizes of anchor dash fastener, all complete as per manufacturer's specification and direction of engineerin- charge.
19Providing and fixing 37 mm thick factory made PVC door shutter, styles and rails made of PVC hollow section of size 100 mm x 37 mm with wall thickness 2 mm (± 0.2 mm), with inbuilt bead on one side, styles and rails mitered cut and joint at the corners by means of 2 nos of plastic brackets of size 75 mm x 220 mm at each corner and stainless steel screws, reinforcing the hinge side of style by inserting PVC profile of size 28 mm x 30 mm, with wall thickness 2 mm ( ± 0.2 mm). Lockrail of size 100 mm x 37 mm, wall thickness 2 mm (+ 0.2 mm) will be fixed to the vertical styles. Providing with PVC snapfit beads and panel of size 100 mm x 20 mm, and inserting 2 nos tie bar of 6 mm dia and fastening with nuts and washers complete, all as per manufacturer's specification and direction of Engineer-in-charge.
20Supply & fixing of M.S. Chain made of 10 mm dia bar with 30mm inner dia ring
21Supply & fixing of Hook 12mm dia bar in CC Step.
22Construction of Embankment with Material Obtained from Roadway CuttingConstruction of embankment with approved materials deposited at site fromroadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5
23Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto1000 mExcavation for roadwork in soil with hydraulic excavator of 0.9 Cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross-sections,and transporting to the embankment location with a lift upto 1.5 m and lead upto 1000 m as per Technical Specification Clause 302.3
24Providing and laying of Empty Cement Bags ( Gunny Bags) filled with localsand and tightened using sutli and carriage upto site including preparingsubgrade before placing in position, also including supply of all material,labour, T&P etc required for proper completion of the work.
25Providing and laying of wire crates 3.00x1.50x1.50 in size with GI wireconforming to IS: 280 & IS:4826 in 150mm x 150mm mesh laid with stoneboulders. as per direction of Engineer-in- charge. (As per PWDUttarakhand specifications)GI wire 8 gauge BWG
26Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203 Brick masonry in 1:4 cement mortar
27WBM Grading 2Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405
28WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.
29Providing and fixing 10x10x7.50 cm Granite stone block hand cut and chisel dressed on top, for paving in floors, drains etc. laid over 20 mm thick base mortar 1:4 (1 cement : 4 coarse sand) with joints 10 mm wide filled with same mortar including ruled pointing etc. complete as per direction of engineer-in-charge.
30Plastering with cement mortar (1:4),15 mm thick on brickwork in substructure as per technical specification clauses 613.4 &1204
31Providing weepholes in brick work masonry/stone masonary,plain/reinforced concrete abutment,wing wall return wall with 100mm dia AC pipe extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and technical specification clauses 614,709,1204,3.7
32Providing and Laying Reinforced Cement Concrete Pipe NP3 as per design inSingle Row Providing and laying reinforced cement concrete pipe NP3 for culverts on first classbedding of granular material in single row including fixing collar with cement mortar1:2 but excluding excavation, protection works, backfilling, concrete and masonryworks in head walls and parapets Clause 1106. 750 mm dia
33Providing Fitting and fixing mild steel railing complete as per drawing and technical specification clause 1208.2
34Providing and Laying of Interlocking Concrete Block Pavements of M-40 Grade having thickness 80 mm as per drawings and Technical Specification Clause 1504
35Cast in Situ Cement Concrete M20 kerb (Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409) Using Concrete Batching and Mixing Plant PCC M20 for Kerb (Cast in Situ
36Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 R.C.C M 25 Height upto 5m
37Providing and laying reinforced cement concrete in superstructure as per drawing and technical specifications Clauses 800, 1205.4 and 1205.5 R.C.C M 25 Height 5m to 10m
38Supplying, fitting,and placing TMT bar reinforcement in superstructure complete as per drawing and technical specifications Clauses 1002, 1010 and 1202
39Providing and Laying of Interlocking Concrete Blcok (M-35) Pavements having thickness 60 mm as per drawing and Technical Specification Clause 1504
40Plantation,(Trees ,Plants Etc.)
41Painting on Steel Surfaces Providing and applying two coats of ready mix paint including primer coat of approved brand on steel surface after through cleaning of surface to give an even shade as per drawing and Technical Specification Clause 170
42Finishing walls with textured exterior paint of required shade :New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm
43Road Work
44Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto1000 mExcavation for roadwork in soil with hydraulic excavator of 0.9 Cum bucketcapacity including cutting and loading in tippers, trimming bottom and sideslopes, in accordance with requirements of lines, grades and cross-sections,and transporting to the embankment location with a lift upto 1.5 m and leadupto 1000 m as per Technical Specification Clause 302.3
45WBM Grading 2Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405
46WBM Grading 3 Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.
47Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203. PCC M-15 Nominal mix (1:2.5:5)
48Providing and Laying of Interlocking Concrete Block (M-35) Pavements having thickness 80 mm as per drawings and Technical Specification Clause 1504.
49Building Work
50Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. All kinds of soil
51Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
52Filling available excavated earth (excluding rock) in trenches ,plinth,sides of foundation etc . in layers not exceeding 20cm in depth ,consolidating each deposited layer by ramming and watering lead upto 50m and For all lift.
53Filling with available fly ash and earth (excluding rock) in trenches or embankment in layers (each layer should not exceed 15 cm), with intermediate layer of compacted earth (Soil density of 98%) after every four layers of compacted depth of fly ash, sides & top layer of filling shall be done with earth having total minimum compacted thickness 30 cm or as decided by Engineer -in-charge, including compacting each layer by rolling/ ramming and watering, all complete as per drawing and irection of Engineer -in - charge.
54Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
55Providing and laying in position cement concrete 1:4:8 (1cement :4 coarse sand:08graded brick aggregated 40mm .nominal size.) excluding the cost of centering and shuttering - All work upto plinth level
56Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement :3 coarsesand : 6graded stoneaggregate 20mm nominal size) over 75mm bed by dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth
57Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.“(Note :- Cement content considered in this item is @ 330 kg/cum.“Excess/ less cement used as per design mix is payable/recoverable separately).All works upto plinth level
58Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Concrete of M25 grade with minimum cement content of 330 kg /cum
59Centering shuttering including strutting, propping etc. and removal of form work
60FOUNDATION UP TO PLINTH (Foundations, footings, bases of columns, etc. for mass concrete )
61COL SUPER STRUCTURE(Columns, Pillars, Piers, Abutments, Posts and Struts
62Roof Beam lintels, beam, plinth beam, girders bressmers, cantilever.
63Slab (uspended floors, roofs, landings, balconies and access platform)
64Lintel+sunshade lintels, beam, plinth beam, girders bressmers, cantilever.
65Reinforcement for R.C.C work including straighting,cutting,bending ,placing in position and bending all complete Thermo-Mechanically Treated bars.
66Brick work with common burnt clay F.P.S. (non modular) bricks of class esignation 7.5 in foundation and plinth IN Cement mortar 1:6
67brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : cement mortar 1:6 (1 cement : 6 coarse sand )
68half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. in cement mortar 1:4 ( 1 cement : 4 coarse sand)
69Extra for providing and placing in position 2 Nos. 6mm dia. M.S.bars at every third course of half brick masonry (with F.P.S.bricks).
70Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
71roviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding
72Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete. With 12 mm mild steel U beading.
73Providing and fixing chromium plated brass handles with necessary screws etc. complete: 75 mm
74Providing and fixing aluminium sliding door bolts, ISI marked anodised(anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete : 300x16 mm
75Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete 100x10 mm
76Providing and fixing aluminium hanging floor door stopper ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper
77Providing and fixing PTMT door catcher of length 72 mm and dia. of 42 mm with suitable washers weighing not less than 33 gms.
78Providing and fixing M.S. Tubular frames for windows, ventilators with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
79Providing and fixing M.S. Tubular frames for doors and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
80Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with 4.0 mm thick glass panes
81Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 -part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover
82Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
83P/F 1st quality ceramic glazed wall tiles conforming to IS : 15622 of approved make in colours , shades except burgandy , bottel green , black of any sizes as approved by Engineer -in -Charge in skirting , risers of steps and dados over 12 mm thick bed of cement mortar 1:3 and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
84Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conformingto IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete
85Marble stone flooring with 18 mm thick marble stone, as per sample of marble approved by Engineer-in-charge, over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with grey cement slurry, including rubbing and polishing complete with : Udaipur green marble
8612mm thick plaster on the plain in side of mix 1:6 ( 1 cement : 6 fine sand) mortar
8715mm thick plaster on the plain in side of mix 1:6 ( 1 cement : 6 fine sand) mortar
88Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre
89Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90ltr./10 sqm)
90Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable sq.m shade with ordinary paint of approved brand and manufacture.
91Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
92Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size)
93Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : In 75x75 mm deep chase
94Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid
95Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
96Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 100 MM
97Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 75 MM
98Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 75 mm
99Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Coupler 110 mm
100Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single Pushfit Coupler 75 mm
101Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single Pushfit Coupler 110 mm
102Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single Tee with Door 75 mm x75mm x75mm
103Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single Tee with door 110 mm x 110mm x110mm
104Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single Tee without door 75 mm x75mm x75mm
105Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Single Tee without door110 mm x 110mm x110mm
106Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 75 mm bend
107Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5° 110 mm bend
108Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Shoe (Plain) 110 mm shoe
109Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete 75 mm
110Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete 110 mm
111Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
112Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall 15mm dia nominal Dia pipe
113Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall 25 mm dia. nominal Dia pipe
114Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge Internal work - Exposed on wall 50 mm dia. nominal Dia pipe
115Providing and fixing ball valve (brass) of approved quality complete High or low pressure with plastic floats 15 mm dia. nominal bore
116Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore
117Providing and fixing uplasticised PVC connection pipe with brass unions : 15mm nominal bore
118Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
119Providing & Fixing C.P. brass bib cock parryware make
120Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. 15 mm nominal bore
121Providing and fixing PTMT pillar cock of approved quality and colour 15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms
122Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 15 mm nominal dia
123Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931: 15mm nominal dia
124Providing and fixing PTMT soap Dish Holder having length of 138 mm, breadth 102 mm, height of 75 mm with concealed fitting arrangements, weighing not less than 106 gms.
125Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms
126Providing and fixing toilet paper holder :C.P. brass
127Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 25 mm nominal inner dia Pipes
128Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore
129Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455x610 mm and 45 cm deep for single pipe line : for sanitary building
130Construction of septic tank AS PER AOR
131Excavating trenches by mechanical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated and then returning the soil as required, in layers not exceeding 20 cm lead of 50m: depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within :All kinds of soil pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
132Providing and fixing on wall face unplasticised Rigid PVC pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
133Overhhead Tank
134Providing of all materials, Carting from site store to site of work, Laying & jointing of G.I. pipes conferming to IS: 1239 (PART-1) including supply of all jointing materials like specials, white lead, hemp and oil etc in trenches with its cutting, threading,and testing of pipe line etc. complete. 20mm dia pipe
135Providing of all materials, Carting from site store to site of work, Laying & jointing of G.I. pipes conferming to IS: 1239 (PART-1) including supply of all jointing materials like specials, white lead, hemp and oil etc in trenches with its cutting, threading,and testing of pipe line etc. complete 25 mm dia pipe
136Providing of all materials, Carting from site store to site of work, Laying & jointing of G.I. pipes conferming to IS: 1239 (PART-1) including supply of all jointing materials like specials, white lead, hemp and oil etc in trenches with its cutting, threading,and testing of pipe line etc. complete 32 mm dia pipe
137Providing of all materials, Carting from site store to site of work, Laying & jointing of G.I. pipes conferming to IS: 1239 (PART-1) including supply of all jointing materials like specials, white lead, hemp and oil etc in trenches with its cutting, threading,and testing of pipe line etc. complete 16 mm dia pipe
138Excavation in soil mixed with single bouldres etc. requireing the use of specials T&P, if any, for pipe line trenches including lift up to 1.5M and lead up to 30M with back filling, watering,ramming of excavated earth in the trenches jns 53.01
139Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), including necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 CPWD 18.33.1
140Providing & fixing brass G.M.valve/ Wheel Valve in position including all materials, labour , T&P etc complete. 20mm dia
141Providing & fixing brass G.M.valve/ Wheel Valve in position including all materials, labour , T&P etc complete 25mm dia
142Providing & fixing brass G.M.valve/ Wheel Valve in position including all materials, labour , T&P etc complete 32mm dia
143Providing & fixing brass G.M.valve/ Wheel Valve in position including all materials, labour , T&P etc complete 15mm dia
144Supply of all materials, labour, T&P etc and construction of R.C.C. O.H.T. of following capacities (in kiloliters) and 12 m. staging with 1.00 m wide R.C.C. stair case from G.L. to balcony and from balcony to top dome Im x Im R.C.C. landing at suitable locations and railed with 3 rows of 20 mm dia G.I. (M) pipe on 65x65x5 mm angle iron posts fixed with ladder, from top to the floor inside of the tank, M.S. M.H. cover with locking arrangement, lightning conductor as per electricity rules, water level indicator, supply and fixiing of outlet, inlet, over flow and wash out pipes with necessary sluice valves, pipe pieces (including cost of materials) flooring 0.60 M wide apron, painting on tank body vertical pipes, ladder, M.S. M.H. cover, ventilator column etc. complete with approved water proofing (apex)/enamal paint, testing, filling water for testing purpose etc. including supply of vertical pipes and specials, assuming bearing capacity as 8MT / M² and staging 12.00 metre jns 53.01
145Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared.
146Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B
147Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
148Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
149Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
150Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
151Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.(20) 2 Pair
152Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20mm (T.V+Telephone+Network)
153Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
154Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 A switch
155Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 A socket outlet
156Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
157Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75 mmX75 mm)
158Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module 3 Module (100 mmX75 mm)
159Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module 4 Module (125 mmX75 mm)
160Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module 6 Module (200 mmX75 mm)
161Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module 8 Module (125 mmX125 mm)
162Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module 12 Module (200 mmX150 mm)
163Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
164Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
165Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
166Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
167Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
168Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.12 Module
169Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
170Supplying and flxing brass batten/angle holder including connection etc. as required.
171Installation, testing and commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/ LED lamps per fitting, complete with all accessories including connections etc. as required.
172Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS PVC insulated, copper cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required.
173Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
174Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
175Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep
176Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
177Building Electrical
178Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.1 run of cable
179Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.2 run of cable
180Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.3 run of cable
181Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FRLS PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 4 way (4 + 12), Double door
182Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
183Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
184Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
185Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
186Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
187Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required
188Supply of AC 230/250 volts, 50 HZ exhaust fans including providing nuts, bolts, mounting frame and other accessories etc. complete 300 mm sweep 900 rpm
189Supply of type fluorescent tube light fitting suitable for 1*18w fluorescent tube complete including tubes etc. on surface complete in all respects. philips 18 w
190Supply of SYSKA Self Ballasted LED Lamps for General Lighting Service 12 Watts 4 Star complete including tubes etc. on surface complete in all respects. (Rate taken from GeM)
191Supply of LT XLPE PVC aluminium Unarmoured cable 25 Sq.mm 4core 1100 volt.
192Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
193Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe FRLSom earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
194Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, copper tube, having single prong at top, with 85 mm dia 6 mm thick copper base plate including holes etc. complete as required.
195Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required.
196Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run)
197Providing and fixing copper tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For vertical run)
198Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
199Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 25 sq. mm (28mm)
200Supply of ADP Octagonal Pole single Arm 6 m. height. Compitable for post top range. as approved by Engineer in charge with making connection complete in all respect. poles with single bracket
201Supply & Installation of LED Street light Yes Wled Luminaire Light approved by Engineer in charge complete in all respect. Cat AA (seg.)
202Supply and erection of factory fabricated and wired metal clad dust and vermin proof Cubical panel MCCB complete with the MCB and instrument chamber etc. complete in all respects. The instrument chamber shall be separate and shall comprise of Digital type ammeter, voltmeter, and selector switches for ammeter and voltmeter, instrument fuses, current transformer etc. The board shall have suitable capacity electrolytic aluminum bush bars as per IS8623 isolated with heat shrink sieving and mounted on non hygroscopic supports such as CMC/DMC support with detachable side covers and shall be suitable for extension on the sides. The switches shall be complete with suitable cable end boxes. reverse entry boxes in The switches board shall be fabricated with CRCA sheet with a minimum thickness of 2 mm cubicle type. A Incoming- 100 Amp MCCB- 1 No.,4p,36 KA Outgoing- 25 Amp MCCB-2 No.,4p, 25 KA, 16 A MCB -1 No,FP 32 A MCB -1 No,DP, (i) Cat A Cubical type
203BLUENEST Reverse Osmosis based Water Treatment System above 50 LPH Capacity Above100 LPH and upto 250 LPH Storage Tank (Inclusive in the scope of Supply) Yes As per \\"Construction of Self Contained Water Cooler\\"
204KSB Three Phase Submersible Pump Set 7.5 kiloWatt KSBR (BPHA 384/02E+UMAI 150-8/22 2.5 SQMM S.D.)
205Electrical Work
206Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
207Earthing with G.I. earth Plate 600mm x 600mm x 6mm thick including accesssories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long with charcoal or coke and salt as required.
208Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
209Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
210Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 90 mm dia (OD-90 mm & ID-76 mm nominal)
211Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
212TWO POLE STRUCTURE: Supplying, fixing, testing and commissioning of two pole structure for receiving 11 KV 3 phase incoming line comprising of :-Supplying, fixing, testing and commissioning of two pole structure for receiving 11 KV 3 phase incoming line from Electricity board comprising of :- 2 nos Steel tubular pole 11 mtrs long, swaged type 410 SP-55 as per IS- 2713. Cement Concrete foundation (1:2:4), 1850 mm below ground abd 450 mm above including excavation and refilling etc. Steel section, channels, angles, flats, clamps, GI nuts, bolts and required hardware etc. of different sizes for cross arms, bracings, supports etc. for pole, insulators, lightning arrestors, GO switch, GI pipe for 11 KV cables, supports for terminations, etc. including anti climbing barbed wires, danger plate etc. 11 KV class disc/pin/support insulator complete with clamps and fixing hardware etc. 3 nos, one per phase, 11 KV station class thyrite type lightning arrestors complete with mounting arrangement on the incoming overhead line along with earthing connections as required. 1 set of G.O. Air break switch with DO fuse 200 Amp. With gang operated devices, with pad locking arrangement. Operating rod, supports, complete with operating handle and locking arrangement 1 Lot - ACSR Conductor and connectors for tapping the connection and for connections with in four pole structure with heat shrinkable insulating sleeves for protection of connections etc. 1 lot -Earth connection with 50 x 6 mm GI Strip.
213Supply , fixing , testing and commissioing of 160 KVA, 11kV/ 433 volt, 3 phase, 4 wire 50 Hz. oil Type ONAN Cu. wound Transformer for outdoor installation with cable box at primary and secondary end, silica gel breather (Completely Self Protected) , 4 star rating as per nigam specification etc. completed as required.
214Supplying, installation, testing and commissioning of 415V, 3 Phase, 50 Hz., 4 wire system, sheet steel clad, dust and vermin proof cubical and outdoor type floor mounted, free standing Main LT Panel with IP - 54 protection, compartmentalized design and fabricated out of 2 mm / 1.6 mm CRCA sheet steel complete with Aluminium Bus bars, Electrical interlocks as per the various status of all the equipments indicated on the drawings. Providing & Fixing of base plate / channel, P/F the following Switchgears, complete with earth Bus bar throughout the length of the panel, terminal arrangement for Incomings / Outgoings cables and also outgoing terminations for various sizes of cables, The incoming and outgoing feeders shall be accommodated in a modular multi-tier arrangement, adequate size bus duct/cable alley, Sign writing, Painting, Earthing, Numbering, Danger plate etc. complete as required as per specifications and drawing. MAIN LT PANEL INCOMING: 2 nos. 250A 415V, 4P 36kA MCCB with O/L, S/C/ , E/F , O/V, U/V Protection and ON /OFF/TRIP Indications with MCB. 2 nos. 250A 415V, 4P Contactor. 2 nos. Digital type Multifunction Meters to show (V, A, kWh, KVAh, KW, KVA, KVAR, PF, Hz.) with cast resin CTs. 2 nos. Reverse Power Relay 2 Set of LED phase indicating lamps with MCB protection. 1 no. TPN surge protection device of Class 1 & 2. BUSBARS: 1 Set of TPN aluminium bus bar of minimum of 300 A capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc, for withstanding fault level of 36 KA for 1 Sec. INTERLOCKING: Electrical Interlocking between all incomers. 8 nos. 63A 415V, TP+Neutral Link MCCB of 25kA with O/L and S/C protection and a set of CT's., Multi Function meter (V+A) AMF system shall be provided within Main LT Panel for One no. 160 KVA DG Set .
215Feeder Pillar: Supply, installation, testing & commissioning of Feeder Pillar having IP55 Outdoor 17U Network Rack with Hood and FAN For field devices. The Rack box shall be provided with external earthing lugs 5 socket. Power terminaton with MCB or more proper/sturdy fixing through RCC base as per site requirements is under bidder’s scope. Make- Rittal/ Satellier/ Valrack.
216HT/LT cable Supplying of 1C x 70 sq.mm XLPE Al. armoured cable, 11 KV grade, conforming to IS : 7098 Part-II and as per specification.
217Supply of the following size XLPE insulated PVC sheathed aluminium conductor armoured cables as per IS:7098(part-1)3 1/2 x 185 sq.mm
218Supply of the following size XLPE insulated PVC sheathed aluminium conductor armoured cables as per IS:7098(part-1)3 1/2 x 70 sq.mm
219Supply of the following size XLPE insulated PVC sheathed aluminium conductor armoured cables as per IS:7098(part-1)3.5C x 50sq.mm
220Supply of the following size XLPE insulated PVC sheathed aluminium conductor armoured cables as per IS:7098(part-1)4C x 35 sq.mm
221Supply of the following size XLPE insulated PVC sheathed aluminium conductor armoured cables as per IS:7098(part-1)Supply of the following size XLPE insulated PVC sheathed aluminium conductor armoured cables as per IS:7098(part-1)4C x 16 sq.mm
222Supply of the following size XLPE insulated PVC sheathed aluminium conductor armoured cables as per IS:7098(part-1)4C x 10 sq.mm
223Supply of the following size XLPE insulated PVC sheathed aluminium conductor armoured cables as per IS:7098(part-1)2C x 10 sq.mm
224Street Lighting Pole 7.00M. Double Arm: Supply, Installation, testing and commissioning of Galvanised steel octagonal pole with double arm bracket, with mounting height of 7 Mtr above ground level for street lighting .minimum sheet thickness 3mm or as per design whichever is higher, with embedded/built-in/separate 3-way junction box (including MCB, connector, 3C x 2.5 Sqmm Cu PVC flexible cable within the pole etc.) with IP65 protection (suitable for looping & termination of 4CX16 sqmm Al XLPE armoured cable), hot-dip galvanised internally and externally to 80 microns DFT. (2 nos. street light luminaires per pole. Foundation and foundation bolts is in scope of street light supplier/vendor. )
225Steet Lighting Luminaire: Supply, installation, commissioning of 45W LED Street light is made of pressure die cast aluminium housing having appropriate heat sink fins with corrosion resistant powder coat, both optical and electrical compartment having Ingress Protection of IP 66 rating and UV-stabilized Heat resistant PC Diffuser. The fixture consists of integral driver to operate wide voltage range from 150V to 270V 50/60Hz application.The luminaire wattage is 45W and with efficacy not lower than 100 lumen/watt, colour temperature of LED is 5700K +/- 355K and CRI is 70, and is provided with structured LED array for optimized roadway photometric distribution with photometric lenses designed to optimize application efficiency and minimal glare. Driver compartment is of IP66 level of protection and the Driver has THD < 10% and PF > 0.95 with Surge Protection as per IEC 61000-4-5 level-4 of 4KV. LEDs are LM80 Compliant with TM21 report for L70 life of 50000 hrs at 85 Deg C, tested and certified from NABL accredited LAB similar to WIPRO cat. no. LR02-501-XXX-57-G1 or eqv.
226High Mast 20M. with 12 Lamp Carriage: Design, Manufacture, Supply, installation, testing & commissioning of 20M high mast complete in all respects including electrically operated raising and lowering gear, double-drum winch with steel wire ropes, integral power tool, lantern carriage, top pulley arrangement complete with hot-dip galvanised finish, RCC foundation with excavation in soil, foundation bolts, anchor plates, nuts, washers including multicore copper conductor cable (Trailing cable) in two circuits (each for 12 nos. 250W LED Light Fixture) of suitable current-carrying capacity between top carriage and the base terminal (inside mast) including provision of outdoor type double-door feeder pillar made of 14swg CRCA sheet with powder-coated paint, comprising of suitably rated one no. incomer TP MCCB of 25KA and two nos. outgoing circuits with TP MCB(s) of 10KA, Auto ON/OFF with astronomical switch, contactor(s) , timer toggle switches, interconnecting copper wiring, etc. as required suitable for operation on 415V, 3-phase, 50Hz, AC power supply. The scope of work also includes installation of 12 nos. floodlight luminaires, provision of lightning arrester, one no. LED obstruction light fixture erected with lantern carriage and connected in two separate wiring/connections from mast control board, extending earth strip from feeder pillar to mast body, connections, interconnections, complete as required and as specified.
227Supply of 250W LED FLOOD Light Luminaire with initial system lumen of 25000 lumen and minimum system efficacy ≥ 100lm/W. Housing shall be Die Cast Aluminium . IP66 , Optics:Toughened Glass. The operating CCT shall be 5700K with CRI of ≥70. The luminaire shall be with BIS Registered electronic driver with input voltage range of 150 to 270V , THD ≤ 10% & PF ≥ 0.95, 50,000 Hrs LED Life with L70 Criteria.The LED Driver shall be easily avaiable in India for repair and service. The LED shall be SMD type. Luminaire shall have minimum surge protection of 4KV.The luminaire shall be with following certifications: LM79 & LM80 issued by LED manufacture along with Photo Biological Safety Standard. similar to Wipro Cat No LF20-342-060-57-G2 or eqv
228Supplying, erection, testing and commissioning of pole of 3 meter height.Finish : Coated with epoxy zinc phosphate primer and finished using environmentally stable polyurethane based paint.Applications : Ideally suitable for entrance to memorials, pathways, garden, residential road and similar locations.Installation : Surface mounted with base plate and fitted on a pre formed foundation, with 20W LED post top Light , prewired control box with service door including lock and safety chain, supplying and fixing of 6 Amp SP MCB C-Series and 32 Amp heavy duty connector etc. for making connections with suitable size of copper wire and thimbles / lugs in the connector box. The pole shall be installed in cement concrete foundation (1:3:6) i.e. 1 cement, 3 coarse sand and 6 graded stone with the help of anchor bolts of 3/4\\" dia by laying iron bar mesh fabricated with 6mm dia iron bar, earthing of pole, connection etc. complete as required. (The light shall be of Eq. to K Lite cat no. 6619).
229Supply, fixing, Testing & Commissioning of Surface mounted LED bollard 16W with IP 65 rating, luminaire made of extuded aluminium alloy (grade 6063) with die-cast aluminium components and non corrosive SS fasteners, reflector system made of spun aluminium(powder coated white), non yellowing UV stabilized polycarbonate clear diffuser, silicon gasket, Cast Iron / aluminium mounting plate for bolting onto a foundation. Luminaire can be aligned on the mounting plate around 360°.The Light shall be fixed with proper nut/screw. The job includes cost of labour, Civil work and petty material required to complete the job to the entire satisfaction of EIC of the work.(The Light shall be Eq. to KLite cat no. KP 7050).
230Providing ,Installing and commissioning of Silent type Diesel generator set along with having Prime Power rating of 160 kVA ,415 volt at 1500 Rpm,0.8 lagging power factor at 415 v suitable for 50 Hz, 3 phase system & 0.85 load factor and consisting of following: Engine mounted instrument panel fitted with and having digital display for following Start -stop switch with Key, water temperature indication, Lubrication oil pressure indication, Lubrication oil temperature indication, Battery Charging Indication, RPM Indication, Over speed indication, Low Lub. Oil trip indication, Engine Hours indication, Alternator, Synchronous alternator rated at 160 KVA,415 volts at 1500 Rpm ,3 Phase 50 Hz,AC supply with 0.8 Lagging power factor at 40 Degree C,50 % RH & at 1000 Metre MSL.The alternator shall be having SPDP enclosure,Brushless,Continous duty, Self excited and self regulated through AVR conforming to IS: 4722/BS 2613 suitable for tropical condition and with class-F/H insulation. Base Frame &Foundation: Both the engine and alternator shall be mounted on suitable Base frame made up of MS channel with necessary reinforcement which shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendation of manufacturer. Exhaust System: Dry exhaust manifold with hospital exhaust silencer and catalytic convertor. Starting System: 12V/24V DC Starting system comprising of starter motors : Voltage Regulator and arrangement of for initial excitation complete with suitable nos of batteries(25 Plates,180 Amp. Hours Capacity Lead acid type)as required as per specification. Acoustic and weather proof enclosure with arrangement fresh air intake for cooling of the engine & alternator,extraction,discharging hot air in to the atmosphere as per specification
231Copper control cable amoured type XLPE 1.1KV grade2Cx2.5sqmm
232Copper control cable amoured type XLPE 1.1KV grade4Cx2.5sqmm
233Copper control cable amoured type XLPE 1.1KV grade12Cx2.5sqmm
234Copper control cable amoured type XLPE 1.1KV gradeTermination of the above cables Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56915624
AUTHORITY Government Departments
TENDER VALUE 80.15 Crore
LAST DATE 27-08-2026
Authority
Authority Name Department Of Irrigation
Work Description Tender for Construction Of Ghat And Astha Path On Left Bank Of Ganga River In Gaurishankar Area In Downstream Of Chandi Ghat In District Haridwar
Basic Detail
Tender No 10/SE/2026-27 DATED 07-08-2026
Bidding Type Tender
Location
City Haridwar
State Uttarakhand
Key Dates
Publish Date 10 Aug 2026
Submission Date 27 Aug 2026
Open Date 27 Aug 2026
Finance
Tender Value 80.15 Crore
Tender Fee 5900
EMD 1.05 Crore
Exemption Available
Document List
14f3e428-8bdb-47ff-9633-631370de04c7.html
BOQ_116509.xls
DRAWING_GAURISHANKAR.pdf
SBD_GAURI_SHANKAR.pdf
Tendernotice_1 (17).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 10, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Aug 27, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
html

14f3e428-8bdb-47ff-9633-631370de04c7.html

xls

BOQ_116509.xls

pdf

DRAWING_GAURISHANKAR.pdf

pdf

SBD_GAURI_SHANKAR.pdf

pdf

Tendernotice_1 (17).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders