Tender For Repair/ Preventive Maintenance Of Summer Appliances At Dscc Under Ge Dronachal
Tender Value
10 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
6 days left
EMD
20000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bhopal → Madhya Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Repair/ Preventive Maintenance Of Summer Appliances At Dscc Under Ge Dronachal
BOQ
| Sl. No. | Item Description |
| 1 | M & L for sub main wiring along with earth wire drown through PVC case & caping for split type A/Cs with FRLSH PVC insulated, unsheathed multi stranded copper single core cable of size 2 x 2.5 sqmm and 1 x 2.5 sqmm for earth wire including taking down old wiring all as directed. |
| 2 | M & L for sub main wiring along with earth wire drown through PVC case & caping for split type A/Cs with FRLS PVC insulated, unsheathed multi stranded copper single core cable of size 2 x 4.0 sqmm and 1 x 4.0 sqmm for earth wire including taking down old wiring all as directed. |
| 3 | Supply & fixing in repairs single pole and neutral enclosure with a two pin and socket complete with one single pole MCB 240 volts, 20 Amps |
| 4 | M & L for servicing of split type AC of capacity 1.5/2 TR of any by opening the condenser unit fixed on roof top and cooling unit fixed inside the building, and cleaning the complete condenser unit and cooling unit including fins, blower fan motor and checking and testing of all parts for its serviceability, oiling/greasing to condenser cum blower fan motors, remore replacing worn out rubber, bushes/rubber packing, rectification of unusal noise, checking of refrigerant standing pressure, replacement of minor parts such as nut/bolt washers etc and reassembling of complete AC including testing for smooth functioning complete all as directed by Engineer-in-Charge.Note: Spare parts will paid in relevant item here in after:- |
| 5 | Supply only of air filter of size 10 micron Split type AC 1.5/2 TR |
| 6 | Supply only Blade for condensing fan motor Split type AC |
| 7 | Supply only running Capacitor 50 Mfd for 2 TR ac |
| 8 | Supply only running Capacitor 45 Mfd for 1.5 TR ac |
| 9 | Supply only condenser coil copper of ac capacity 1.5 TR |
| 10 | Supply only condenser coil copper of ac capacity 2 TR |
| 11 | Supply only suction valve brass type 5/8\\"of ac capacity 1.5 TR |
| 12 | Supply only suction valve brass type 5/8\\"of ac capacity 2 TR |
| 13 | Supply only coil sensor and room sensor for ac capacity of 1.5/2 TR |
| 14 | Supply only swing motor for air adjust of suitable size Make:OEM |
| 15 | Supply only relay for overload of suitable size for ac capacity 1.5/2 TR Make:OEM |
| 16 | Supply fixing and testing new sealed compressor suitable for 1.5 Ton split type air conditioner having operating voltage 200 to 240 volts/50 HZ, duly filled compressor oil and M&L for charging of R-22/R-134A gas in adequate quantity so that during testing effective cooling can be achieved complete in all respect all as specified and directed. |
| 17 | Supply fixing and testing new sealed compressor suitable for 2.0 Ton split type air conditioner having operating voltage 200 to 240 volts/50 HZ, duly filled compressor oil and M&L for charging of R-22/R-134A gas in adequate quantity so that during testing effective cooling can be achieved complete in all respect all as specified and directed. |
| 18 | S & F of OEM compatible Indoor unit PCB complete for inverter type split AC up to 2.0 TR including dismantling, reconnecting, testing and commissioning complete all as directed by Engr in Charge. |
| 19 | S & F of OEM compatible Outdoor unit PCB complete for inverter type split AC up to 2.0 TR including dismantling, reconnecting, testing and commissioning complete all as directed by Engr in Charge. |
| 20 | M&L for removing the cooling fan motor of capacity 1/30 or 1/35 HP from split type AC 1.5 TR,and S&F the same complete all as directed by Engr-in-Charge. |
| 21 | M&L for removing the cooling fan motor of capacity 1/30 or 1/35 HP from split type AC 2 TR,and S&F the same complete all as directed by Engr-in-Charge. |
| 22 | S&F of blower motor of capacity 1/30 or 1/20 HP split type AC 1.5/2TR. Complete all as directed. |
| 23 | Supply and filling of Refrigerant gas R-134A in Air conditioner/ refrigerator/ deepfreezer/water cooler at different site as required including brazing and removal of leakage in equipment |
| 24 | Supply and filling of Refrigerant gas R-22 in Air conditioner/ refrigerator/ deepfreezer/water cooler at different site as required including brazing and removal of leakage in equipment |
| 25 | Repair, servicing, testing and commissioning of 4 TR tower type air conditioner, including dismantling and reassembling of indoor and out door units, cleaning of evaporator and condenser coils, blower assembly and air filters, checking and tightening of compressor, condenser fan motor and blower motor checking and topping up refrigerent gas (if required), replacement of minor consumable such as insulation tape, cable lugs, screws, nuts, bolts and terminals, checking of thermostat sensors, PCB, contactors, relays and capacitors, performance testing, caliberation and restore the unit to satisfactory working condition, complete all as specified and as directed by Engr-in-charge.Note- Major spare measure and paid separately |
| 26 | Repair, servicing and testing of 4 TR cassette type Air conditioner, including inspection, fault diagnosis, cleaning of indoor and outdoor units, condenser and evaporator coil cleaning, checking and tightening of electrical connections, testing of compressor, fan motors, capacitors, PCB, contactor, thermostat, condensate drain line, refrigerant pressure checking, leak detection,refrigerant top up (if required) ,replacement of minor consumables, testing and commissioning complete all as directed by Engr-in-charge. |
| 27 | M & L for wall mounted Stablizer of capacity 4 KVA including Fuze assy, terminal panels, indicators, time delay relay and 3 core PVC lead and re-assembling and fixing in position complete all as directed by Engr in Charge. |
| 28 | M & L for wall mounted Stablizer of capacity 5 KVA including Fuze assy, terminal panels, indicators, time delay relay and 3 core PVC lead and re-assembling and fixing in position complete all as directed by Engr in Charge. Please Enable Macros to View BoQ information |
| 29 | M & L for wall mounted Stablizer of capacity 5 KVA including Fuze assy, terminal panels, indicators, time delay relay and 3 core PVC lead and re-assembling and fixing in position complete all as directed by Engr in Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysSep 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 9 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender