Defence Government Departments Closing in 6 days TDR #56912651

Tender For Arm Of Station Hqrs (Arm Of Primarysschool, Ankur School, Shopping Complex, Unikrishnan Stadium, Dg Hut, Sub-Station, Water Pumping Stations, Sarv Dharam Sthal, Surender Kumar Gym, Shaurya Sthal, Noi Insitiute, Lawn Tennis Court, Station H

Issued by Government Departments · Gurgaon, Haryana
Tender Value
49.49 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
6 days left
EMD
98989
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gurgaon → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Arm Of Station Hqrs (Arm Of Primarysschool, Ankur School, Shopping Complex, Unikrishnan Stadium, Dg Hut, Sub-Station, Water Pumping Stations, Sarv Dharam Sthal, Surender Kumar Gym, Shaurya Sthal, Noi Insitiute, Lawn Tennis Court, Station Hqrsbbuildings, Nwya Buildings, Dwelling Units, Tcp-1 & 2 And Other Central Buildings) Of Nsg C Manesar For The Year 2026-27(Sh: Civil & Electrical Maintenace)

BOQ

Name of Work:- ARM of Station HQrs (ARM of PrimarySschool, Ankur School, Shopping Complex, Unikrishnan Stadium, DG Hut, Sub-station, Water Pumping Stations, Sarv Dharam Sthal, Surender Kumar Gym, Shaurya Sthal, NOI Insitiute, Lawn Tennis Court, Station HQrsBbuildings, NWYA Buildings, Dwelling units, TCP-1 & 2 and other Central Buildings) of NSG C Manesar for the year 2026-27(SH: Civil & Electrical Maintenace)
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
2All kinds of soil.
3Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth
41:1.5:3 (1 Cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
51:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
61:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources)
7Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
81:1.5:3(1 cement: 1.5 coarse sand (zone-Ill) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
9Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement:
101:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
11Centering and shuttering including strutting, propping etc. and removal of form for
12Foundations, footings, bases of columns, etc. for mass concrete
13Shelves (Cast in situ)
14Lintels, beams, plinth beams, girders, bressumers and cantilevers
15Edges of slabs and breaks in floors and walls
16Under 20 cm wide
17Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
18Thermo-Mechanically Treated bars of grade Fe-500D or more.
19Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
20Cement mortar 1:6(1 cement :6 coarse sand)
21Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
22Cement mortar 1:6(1 cement : 6 coarse sand)
23Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :
24Gang saw cut stone
2530 mm thick Red sand stone
26Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
2730 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
28Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
29Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS: 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
30300x16 mm
31250x16 mm
32Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
33200x10 mm
34100x10 mm
35Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
36100 mm
37Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
38Twin rubber stopper
39Providing and fixing aluminium casement stays, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
40Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
41Providing and fixing to existing door frames.
4230 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/ Polystyrene foam to be used as filler material throughout the hollow panel, casted monolithically with testing parameters of F.R.P. laminate conforming to table 3 of IS: 14856, complete as per direction of Engineer-in-charge.
43Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
44With 12 mm mild steel U beading
45Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds
46Casement door single panel with zinc alloy (zamak) 3D hinges, multi-point locking system with cylinder, zinc alloy (zamak) powder coated handles on both sides.
47Using R3 series with frame (55 mm & above) x (50 mm & above) & sash (55 mm & above) x (85 mm & above) (Height upto 2.5 metre).
48Two and half track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.
49Using R2 series with frame (65 mm & above) x (40 mm & above) & glazed sash (25 mm & above) x (50 mm & above) & fly screen sash (18 mm & above) x (40 mm & above) with zinc alloy (zamak) powder coated touch locks with hook (Height upto 1.2 metre).
50Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
51Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
5280x1.20 mm M.S. laths with 1.20 mm thick top cover
53Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
54Hot finished welded type tubes
55Providing and fixing mild steel round holding down bolts with nuts and washer plates complete.
56Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, bufing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
57Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.
5840 mm thick with 20 mm nominal size stone aggregate
59Providing and fixing glass strips in joints of terrazo/ cement concrete floors.
6040 mm wide and 4 mm thick
61Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
6225 mm thick.
63Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
64Glazed Vitrified tiles Matt/Antiskid finish of size
65Size of Tile 600 x 600 mm
66Providing and laying full body vitrified tile in floor of minimum thickness 15 mm with water absorption less than 0.06% and conforming to IS:15622, of approved make, brand and manufacturer, laid on 20 mm thick base cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.30 kg / sqm including grouting the joints with white cement and matching pigments etc. The slab must be cut with the zero chipping diamond cutter only. Laying of slab will be done with the help of notch trowel, wedge, clips of required thickness, vacuum cups for lifting, leveling system and rubber mallet for placing the slab gently and easily. Size of tile 800x2400 mm of all colours and shades.
67Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
68110 mm diameter
69Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS :5382, leaving 10 mm gap for thermal expansion.
70Coupler
71110 mm
72Single tee with door
73110x110x110 mm
74Single tee without door
75110x110x110 mm
76Bend 87.5°
77110 mm bend
78Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
79Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
80Ridges plain (500- 600mm)
81Flashings/ Aprons.( Upto 600 mm)
8212 mm cement plaster of mix:
831:6 (1 cement: 6 coarse sand)
8415 mm cement plaster on rough side of single or half brick wall of mix:
851:6(1 cement: 6 coarse sand)
86Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
87New work (Two or more coats applied @ 1.43 Itr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
88Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
89Two or more coats on new work
90Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
91Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade:
92One or more coats on old work
93Finishing walls with Acrylic Smooth exterior paint of required shade:
94Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface
95Old work (One or more coat applied @0.90 Itr/10 sqm).
96Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade
97Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
98With cement mortar 1:4 (1cement: 4 coarse sand)
99Renewing glass panes, with putty and nails wherever necessary including racking out the old putty:
100Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm)
101Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150 mm dia upto 300 mm
102Providing & fixing White vitreous china water closet squatting pan (Indian type) along with “S” or “P” trap including dismantling of old WC seat and “S” or “P” trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material including malba, all complete as per the direction of Engineer-in charge.
103Orissa pattern W.C Pan of size 580x440 mm
104Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge. (a) Internal Work- Exposed on wall
105Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
106Nominal concrete 1:4:8 or leaner mix (including equivalent design mix)
107Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
108Of area 3 sq. metres and below
109Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead :
110Of area 3 sq. metres and below
111Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.
112For thickness of tiles 10 mm to 25 mm
113Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
114Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.
11580 mm thick C.C. paver block of M-35 grade with approved colour design and pattern.
116Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
117W.C. pan with ISI marked white solid plastic seat and lid
118Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:
119White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap
120Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :
121Kitchen sink without drain board
122610x510 mm bowl depth 200 mm
123Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.
12410 litre capacity - White
125Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
126Semi rigid pipe
12732 mm dia
128Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
129Providing and filling the joints with spun yarn, cement slurry and cement mortar 1:2 ( 1 cement : 2 fine sand) in S.C.I./ C.I. Pipes :
130100 mm dia pipe
131Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.
132600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
133Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
134Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litre with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.
135Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall
13620 mm nominal dia Pipes
13725 mm nominal dia Pipes
138Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.
13920 mm nominal dia Pipes
140Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :
14125 to 40 mm nominal bore
142Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :
14320 mm nominal bore
14425 mm nominal bore
145Providing and fixing uplasticised PVC connection pipe with brass unions :
14645 cm length
14720 mm nominal bore
148Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :
149Providing lead caulked joints to spun iron or C.I. pipes and specials, including testing of joints but excluding the cost of pig lead :
150100 mm diameter pipe
151Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :
15215 mm nominal bore
153Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.
15415 mm nominal bore
155Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931.
15615 mm nominal bore
157Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931
15815 mm nominal bore
159Labour for cutting C.I. pipe with steel saw.
160100 mm diameter C.I. pipe
161Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality
162L D- 2.5
163Rectangular shape 600x450 mm internal dimensions
164Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5 kg
165Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
166For fixed portion
167Powder coated aluminium (minimum thickness of powder coating 50 micron)
168For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
169Powder coated aluminium (minimum thickness of powder coating 50 micron)
170Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
171With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
172Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer- in-charge.
173With stainless steel cover plate minimum 1.25 mm thickness
174Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design :
175Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) :
176With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
177Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
178Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.
179Providing and fixing Ist quality ceramic glazed wall tiles (size not less than 300x600mm)conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
180Providing & fixing false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595x595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Non combustible as per BS 476 (part 4)-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on inter-locking metal T-Grid of hot dipped galvanised iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main-T runners of size 15x32 mm of length 3000 mm, cross - T of size 15x32 mm of length 1200 mm and secondary intermediate cross-T of size 15x32 mm of length 600mm to form grid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 50 mm long, 8 mm outer diameter M-6 dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 85x25x2 mm. Galvanised iron perimeter wall angle of size 24x24x0.40 mm of length 3000 mm to be fixed on periphery wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-Charge.
181Correction factor @ 0.973 on DSR items = 3637412.65 x 0.973= 3539202.50 - 3637412.65 = (-) 98210.14
182Cost Index @ 4.03% = 3539202.50 x 4.03% = 142629.86
183Providing & fixing 2mm Luxury Vinyl Roll, in desired tone, colour and pattern, Glue Down by SR 998, Termite and Bugs proof, Superior Stain and Scratch Resistance, Fire Resistance, Chemical Resistance, Zero Maintenance, Easy Soap & Water Cleaning, PUR Polyurethane reinforcement, Phthalate free all complete as per direction of Engineer - in-charge.
184Electrical
185Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable etc as required.
186Group B
187Group C
188Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
189Wiring for light/ power plug with 4X4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 2 Nos 4 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable for loop earthing as required.
190Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
1912 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
192Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
193Group B
194Group C
195Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
1963 x 1.5 sq. mm
1973 x 4 sq. mm
198Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
19920 mm
20025 mm
201Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
202Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required.
2031 or 2 Module (75mmX75mm)
2043 Module (100mmX75mm)
205Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
206Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
207Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
208Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
209Upto 450 mm sweep
210Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
211Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2128 way, Double door
213Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
214Single pole
215Single pole and neutral
216Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps \\"C\\" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
217Brush Less Direct Current (BLDC) Fan without Remote Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR /HFFR, PVC insulated copper conductor single core cable and earthing etc. as required.
2181200mm, service value ≥ 5.1 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
219LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range 15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends,CCT 3000°K / 4000°K / 5700°K /6000°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. complete in all respect i/c connections with 1.5 sq mm FRLS/HFFR , PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm
22018-22watt
221LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends ,CCT 3000°K / 4000°K / 5700°K/6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation ColorMatching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS/HFFR ,
222PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 36 watt
223LED Down lighter (SMD Type) (System lumen Unit Rate efficacy ≥ 105 < 120 lm/Watt). Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) Powder coated die cast /Extruded aluminium Body including trim .
22418watt
225Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Three Pole
226Supplying and fixing Plug top following rating including connection etc. as required.
22716 A 3/6 Pin Plug top
2286 A 3/6 Pin Plug Top
229Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
230Providing, Installation, testing and commisioning of HVLS (High Volume -low speed) Gearless ceiling fans rating in size from 6 to 8 feet in diameter, industrial fans to run continuously designed to operate at slower speeds (around 55-70 RPM) but generayte massive airflow, 6-8 blade, H--class insulation, Super silent <38db, IP 54 controller voltage 220/380 volt supply etc complete commissioning etc as required. Make- Austar/ Marut/SVS or equipvalent make.
231Supply, installation, testing and commissioning of 10 watt Track Mounted Warm White LED light, IP >43, with Pressure Die-cast aluminium housing and complete with PC diffuser, LED module, electronic driver and all other accessories, having PF> 0.9, THD<15%, CRI>80 minimum system luminous efficacy of 90 lm/W, on existing street light pole/gate including connection etc. as required. Make:- Havells, UNECOTRACKLIGHTTS10WLED830S15WHT
232Supply, installation, testing, and commissioning of LED bulkhead fittings with IP 66 ingress protection, with a minimum system lumen output of 1000 lumens and a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature of 5500K–6500 K, average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser, electronic driver, etc. as required directly on the wall, including connections, etc. as required
233Supply, installation, testing and commissioning of wall-mounted light fixture complete with B22/ E27 base, metal base in Nickel / Brass finishing with diffuser and 9 watts LED blub etc., as required directly on the wall, including connections etc. as required. ( Havells FLORETINE WL 1 LS or similar in Wipro/Philips/Jaquar/LT as approved by the Engineer -in- charge)
234Supplying & Fixing of 2 to 4 watt LED wall light as bed light etc required as per direction of engg-in-charge.
235Supply, installation, testing and commissioning of 45 watts LED-based post top luminaires, IP 65, with Die-cast aluminium spigot housing and complete with diffuser, LED module, electronic driver and all other accessories, having minimum system luminous efficacy of 95 lm/W, on existing street light pole/gate including connection etc. as required. (Warm WHite/ Cool White as per decision of Engineer-in-Charge)Make :CORAL (Opal) or RUBY (Clear) of Havells similar in Philips / Havells/ Wipro/ Bajaj
236Supplying, installation, testing, and commissioning of 10 to 11 Watt, 0.6 Metre (nominal size) LED Bollard Light fitting complete with LED module, electronic driver, diffuser, and all other accessories, minimum system luminous efficacy of 80 lm/W, the bollard housing should be made up of metallic pipe duly powder coated with the mounting flange at the bottom,
237including providing 3 nos M10 foundation bolts, two numbers 32 mm. dia PVC pipe for cable entry (from the bottom of the foundation to the top of the foundation for cable entry), and providing the foundation of Cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 20 mm nominal size ) of size 0.3-metre dia and 750 mm height (250mm above ground and 500 mm below ground) including excavation as required and complete with connections, lugs, terminals, connectors for the connection of cable and wires in the fitting etc., complete as required. (Make Havells /Philips /Wipro as per sample approved by Engineer -in - Charge)
238Supplying & fixing of Water Pressure Pump (booster pump) 1 HP, 4 Stage, single phase, 220 volt, Automatic ON and OFF Operation Monoblock motor pump set having suction X delivery size 32 mm X 25 mm, head up to 36 m, tank capacity 24 litre, complete as required. (Model no KSB KHM0404 KSB make)
239Supplying, installation, testing & commisioning of 0 .5 HP / 0.37 KW, single phase, self priming Monoblock motor pump set having Thermal Overload Protector (TOP), IP-44 protection and class 'B' insulation. Suction X delivery size 25 mm X 25 mm and head range 2600 to 500 LPH discharge at 6 to 30 mtr complete with foundation bolt et., as required. (Crompton Minimaster Plus II of similar in CRI/ texmo /KSB/ Kirloskar /Crompton make)
240Supplying and laying of one number PVC/XLPE insulated and PVC sheathed/XLPE aluminium armoured conductor power cable 1.1 KV grade of following size in the existing RCC/ HUME/ STONEWARE/ METAL/ DWC pipe as required.
2412 X 16 Sq.mm
2423.5 X 35 Sq.mm
2433.5 X 120 Sq.mm
244Supplying and laying of one number PVC/XLPE insulated and PVC sheathed/XLPE aluminium armoured conductor power cable 1.1 KV grade of following size in Masonry Open Duct Loose/loop/in panel etc. complete etc as required.
2452 X 16 Sq.mm
2463.5 X 35 Sq.mm
2473.5 X 120 Sq.mm
248Supply and drawing of 3 x 2.5 sq mm PVC insulated, FRLS PVC sheathed copper conductor multi core flexible cable into the existing street light pole, DWC Pipe / loose as per requirement including making connections at one end with the street light fitting fixed to the top of the pole and the other end with the control gearbox, including drawing out the burnt-out wires from the pole if required, etc. as required.
249Supply and drawing of 3 x 1.5 sq mm PVC insulated, FRLS PVC sheathed copper conductor multi core flexible cable into the existing street light pole, DWC Pipe / loose as per requirement including making connections at one end with the street light fitting fixed to the top of the pole and the other end with the control gearbox, ( including drawing out the burnt-out wires from the pole if required), complete etc. as required.
250Supply, Installation, Testing and commissioning of outdoor type totally enclosed, dust and vermin proof, pedestal mounted INSPECTION BOX / JUNCTION BOX of a suitable size but not less than 600 mm wide X 600 mm height X 450 mm (deep) fabricated from 2 mm thick CRCA sheet steel having front and back openable doors with locking arrangement on both sides, tapered top (roof), including detachable cable gland plates made of 3 mm thick CRCA sheet, including pre-paint treatment, phosphating and powder coating by approved Siemens grey paint, consisting of 500 Amps 4 strip aluminium bus bars with heat-shrinkable coloured sleeves and including DMC / SMC bus bar supports at required intervals, etc. as required, suitable for operation on 433 volts, 50 Hz, 3-phase, 4-wire A.C. supply system, the entire panel shall have one common G.I. bar of size 25 mm x 5 mm at the rear with 2 earth studs or terminals, a danger notice plate fixed, etc., complete as required. The feeder pillar should be complete with a mounting frame made of 50 mm x 50 mm x 6 mm angle iron with 900 mm long legs. The 4 legs of the feeder pillar shall be erected on a suitable size 1:3:6 cement concrete (1:3:6 cement; 3 sand; 6 graded stones of 20 mm size) pedestal having 900mm of depth (600mm below ground and 300mm above ground)..
251Supply, installation, testing, and commissioning of a double door type, outdoor type, totally enclosed IP54, dust and vermin proof, powder-coated in an approved Siemens grey shade after 7 tank treatment processes, pedestal-mounted cubical type LT panel. The panel with the required front area (but not less than 1.5 sqm) and a depth of 400 mm, fabricated in a compartmentalised design from 2 mm CRCA sheet steel with fully openable front and back doors with locking arrangements and required gaskets, and a tapered top (roof). The feeder pillar should be complete with 450 amps, 4 strip aluminium bus bars with heat-shrinkable coloured sleeves and including DMC/SMC bus bar supports at required intervals, control terminals and suitably sized terminal blocks for incoming and outgoing cables, including providing interconnections / power wiring from busbars to switch gears and up to terminal blocks with suitable sized solid aluminium strips,
252The wiring for the control circuit shall be carried out using 1.5 sq.mm flexible copper cable, the entire panel shall have one common aluminium/G.I. bar of size 25 mm x 5 mm at the rear with 2 earth studs/terminals, including detachable cable gland plates made of 3 mm thick CRCA sheet, suitable for operation on a 433 volt, 50 Hz, 3 phase, 4 wire A. C. supply system complete as required. and suitable size M.V. Danger Boards shall be fixed on the panel. The feeder pillar should be complete with a mounting frame made of 50 mm x 50 mm x 6 mm angle iron with 900 mm long legs. The 4 legs of the feeder pillar shall be erected on a suitable size of 1:3:6 cement concrete (1:3:6 cement; 3 sand; 6 graded stones of 20 mm size) pedestal having 900mm of depth (600mm below ground and 300mm above ground). The feeder pillar shall have provision to accommodate the following switch gears, as mentioned below in Item No. 125.01-125.130(For Kendriya Vidyalaya)(The drawing will be approved before the fabrication of the panel.)
253Fabrication of Feeder pillar with depth of 400 mm (D), with 450 amp aluminium bus bars and interconnections made of 2 mm thick MS sheet i/c welding, painting, locking arrangement.
254Red Phase indication LED lamps.
255Yellow Phase indication LED lamps.
256Blue Phase indication LED lamps.
2572 Amp SPMCB, Conforms to IS/IEC 60898 - 10kA model No. BB10020C
258Multi-function meter (MFM) with to read V, I, Hz, PF,KW & KWH complete MFM 4405 LED meter Cl 1 with RS485 All parameters of 4400 series in 3 line LED display with suitable selector switch model No. WL440511OOOO
259Insulated Tape Wound CTs 400/5 A amps, 15VA withAccuracy class 0.5, 5P10 in existing cubicle panel board including making connections and teting etc,. as required.
260250 Amp 4 pole, > 25, kA (Ics=Icu) at 433 V Short CKt. Current rating and should be Thermal Magnetic Release, Adjustable overload settings: 0.8 - 1.0 x In Adjustable short-circuit settings: 6 - 10 x In - 1No. DN1-250C, 200-250Amp MCCB, 4 Pole, 25kA, CM90642OOPO
261DN1 Direct ROM Rotary Handel, CM98040OOOO for 250 Amp.
26280 Amp 4 pole, > 25, kA (Ics=Icu) at 433 V Short CKt. Current rating and should be Thermal Magnetic Release, Adjustable overload settings: 0.8 - 1.0 x In Adjustable short-circuit settings: 6 - 10 x In - 1No. DN0-100C, 80-100 Amp MCCB, 4 Pole, 25kA, CM91712OOKOOG
263DN0 Direct ROM Rotary Handel, CM97895OOOO for 80 Amp .
264320 Amp 4 pole, > 36 kA (Ics=Icu) at 433 V Short CKt. Current rating and should be Thermal Magnetic Release, Adjustable overload settings: 0.8 - 1.0 x In Adjustable short-circuit settings: 6 - 10 x In - 1No. DN3B-400D, 320-400 Amp MCCB, 4 Pole, 36kA, CM98403OOROOG
265DN3B, DN3 Direct ROM Rotary Handel, CM99861OOOO for 320 Amp
266Supplying and fixing 320 amps rating, 240/415 volts, CO3-315, Type 315 Amp, Changeover with Sheet Steel Enclosure, complete with terminal shrouds, source separator, Phase barriers, staggered Terminals complete with connections, testing and commissioning etc. as required.(Make:- L&T, CO3-315 Type , CO33150OSOO)
267Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit (IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3. 5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz, 1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42° C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50° C (out door ambient temperature). Inverter Type - Cooling only - 2. 0 TR with 5 Star BEE Rating (Daikin / Blue star / O' General / Mitsubishi/ Voltas/ Carrier )
268Providing & fixing of refrigerant copper piping with insulation and wire for 2 ton Split AC as per manufacturers specification , clamps, etc. complete as reqd. ( two copper pipes one suction and one discharge line with wire and foam insulation tubing will be measured as one unit)
269Supply, Installation, testing and commissioning of wall mounted type voltage stabilizer suitable for 2.0 Ton Split Air conditioner with High / Low voltage cut off, thermal overload relay and Time Delay Relay, WORKING VOLTAGE RANGE : 150-285 Volts including connection etc. as required. (V-Guard make-Model VND 500 or similar of Totaline / Logicstat / Microtek/Luminous / Bluebird with minimum 3 year warranty.)
270Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
27140 mm
272Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
273Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
274Providing and fixing 6 SWG dia GI Wire on surface or in reccess for loop earthing alongwith existing surface/ reccess conduit / sub main wiring / cable as reqired.
275Providing & Fixing 25mmx5mm GI strip on surface or in reccess for connections etc. as required.
276Dismantling of the existing switch accessories like switches, sockets, and MCBs, etc., as required.
277Dismantling of the existing ceiling rose, holder, and wall bracket and depositing the same with the listing of materials in the store.
278Dismantling of existing fluorescent fitting from ceiling/ wall including making good the damage to match the adjacent surface, etc., as required.
279Dismantling of the existing ceiling fan/ exhaust fan of any size installed in the building and depositing it in the MMC store.
280Dismantling of the existing recessed vertical type or horizontal type TPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required.
281Dismantling of the existing recessed SPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required.
282Dismantling of the existing recessed switch board of light points/power points, power/light plug points/socket outlet metal boxes of any size, along with phenolic laminated sheet, switches, sockets, etc., making good the damage to match the adjacent surface, etc., as required.
283Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Above 25 mm conduits.
284Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Up to 25 mm conduit.
285Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
286Less credit for the unserviciable items dismantled items during execution of the work.
287Assorted MCB TP AND TP&N & OTHER SWITCHGEAR
288Assorted PIANO Type Switches
289Assorted PIANO Type Sockets
290Assorted Bell push/PIANO Type
291Assorted Call bell buzzer single phase
292Assorted Brass batten/ angle holder/Brass Bracket
293Assorted Fan regulator/resistance type
294Assorted Telephone Socket outlet
295Assorted T.V. Socket outlet
296Assorted Capacitor, 3.15/2.50/2.25 mfd
297Assorted 1200/1400 mm sweep ceiling Fan with blades
298Assorted Fresh Air FAN 200/250
299Assorted Exhaust fan 300/380/450
300Assorted Wall Bracket Fittings
301Assorted fluorescent Light Fittings
302Assorted Bulk Head Fittings
303less credit for the dismantled Copper wire wires from light points/ circuit/ submain/power circuit wiring,.
304less credit for the dismantled aluminium wire wires from light points/ circuit/ submain/power circuit wiring,.
305Assorted metal switch box.
306Assorted MCB DB SPN with out MCBs
307Assorted MCB DB TPN with out MCBs
308Assorted MCB SP
309Assorted MCB DP
310Assorted MCB TP AND TP&N Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56912651
AUTHORITY Government Departments
TENDER VALUE 49.49 Lakhs
LAST DATE 17-08-2026
Authority
Authority Name National Security Guard
Work Description Tender for Arm Of Station Hqrs (Arm Of Primarysschool, Ankur School, Shopping Complex, Unikrishnan Stadium, Dg Hut, Sub-Station, Water Pumping Stations, Sarv Dharam Sthal, Surender Kumar Gym, Shaurya Sthal, Noi Insitiute, Lawn Tennis Court, Station Hqrsbbuildings, Nwya Buildings, Dwelling Units, Tcp-1 & 2 And Other Central Buildings) Of Nsg C Manesar For The Year 2026-27(Sh: Civil & Electrical Maintenace)
Basic Detail
Tender No 39/CS/2026-27/NSG
Bidding Type Tender
Location
City Gurgaon
State Haryana
Key Dates
Publish Date 08 Aug 2026
Submission Date 17 Aug 2026
Open Date 18 Aug 2026
Finance
Tender Value 49.49 Lakhs
Tender Fee Ref. Documents
EMD 98989
Exemption Not Available
Document List
38671621-d232-492e-8a43-90be9e1f9ad9.html
BOQ_968161.xls
Tendernotice_1 (7).pdf
Tendernotice_2 (2).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 6 days
Aug 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 7 days

Tender Documents

Download All (ZIP) ↓
html

38671621-d232-492e-8a43-90be9e1f9ad9.html

xls

BOQ_968161.xls

pdf

Tendernotice_1 (7).pdf

pdf

Tendernotice_2 (2).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender