Tender For Internal/External Smart Periodical Services Joinery, Plumbing To Civil Zone And Mes Colony Of Camero Complex At Af Station Subroto Park
Tender Value
30 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
21 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Internal/External Smart Periodical Services Joinery, Plumbing To Civil Zone And Mes Colony Of Camero Complex At Af Station Subroto Park
BOQ
| Sl. No. | Item Description |
| 1 | Complete removal or existing treatment on wall/roof projections including facia cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean free from dust loose paint etc by skilled labour complete all as specified and directed. |
| 2 | Material & Labour for Old plaster surfaces of finishing walls with paint of required shade applying Two or more coats of 100% Premium acrylic emulsion paint of having VOC less than 50 gm/litre and UV resistace as per IS 15489:2004. Alkali & Fungal resistance, dirt resistance exterior paint of required shade (Company Depot tinted) with silicon additives @1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 ltr/ 10 sqm over including 1mm thick wall care putty over Old surfaces complete all as specified and directed. Note: Primer and Emulsion to be carried out through air less spray machine (Mechanical Means) Make:- Asian Paint Apex ultima/Berger weather coat long life 10/Nerolac Excel everlast or equivalent. |
| 3 | M&L preparation of old plastered surfaces of wall including cornices etc by brooming down or steel wire brushing scrapping down smoke soot moulds and efflorescent salt and trading and greasy spots and applying one coat of white wash by air less spray machine (Machanical means) of any tint complete all as specified and directed. |
| 4 | M&L preparation of old plastered surfaces of ceiling including cornices etc by brooming down or steel wire brushing scrapping down smoke soot moulds and efflorescent salt and trading and greasy spots and applying one coat of white wash by air less spray machine (Machanical means) of any tint complete all as specified and directed. |
| 5 | M&L for preparation of old distempered surfaces of wall by washing rubbing down and stopping of old distempered surface of wall including cornices etc and also 1mm thick wall putty as required for levelling and applying one coat of primer as required and one coat of oil bound distemper (Oil emulsion any tint) on wall by air less spray machine (Machanical means) complete all as specified and directed (Make:- M/s Asian Paints/Nerolac/Berger or equivalent). |
| 6 | M&L for preparation of old plastered surfaces of walls by washing, rubbing down and stopping of distemper and painted surfaces & applying two coats of distemper oil emulsion over a thin layer of wall care putty complete all as specified and directed (Make:- M/s Asian Paints/Nerolac/Berger or equivalent). |
| 7 | M&L for preparation of old painted surface of wood or wood based material of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enemel paint complete all as specified and directed. (Make:- M/s Asian Paints/Nerolac/Berger or equivalent). |
| 8 | M&L for preparation of old painted steel surface of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. (Make:- M/s Asian Paints/Nerolac/Berger or equivalent). |
| 9 | M&L for preparation of old plastered or unplastered decorated surface of walls and applying one coat of cement base paint by air less spray machine (Machanical means) of any colour complete all as specified and directed. (Make :- Snowcem India or equivalent). |
| 10 | M&L for preparation of old plastered or unplastered decorated surface of walls and applying two coats of cement base paint by air less spray machine (Machanical means) of any colour complete all as specified and directed. (Make :- Snowcem India or equivalent). |
| 11 | M&L for preparation of old painted concrete surfaces/brick surface of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint, complete all as specified and directed. |
| 12 | Taking down cement plaster of any description on brick or concrete surfaces of walls or ceiling etc incl. raking out joints ,hacking for key and scrubbing down with water upto 4 storeys building, complete all as specified and directed. |
| 13 | M&L for 15 mm thick cement plaster in cement mortar 1:4 on concrete or brick surface and finished even and smooth w/o using extra cement upto 4 storeys building with water proofing compound complete all as specified and directed. |
| 14 | M&L for 10 mm thick cement plaster in cement mortar 1:6 on brick surfaces on fair face of brick work and finished even and smooth w/o using extra cement upto 4 storeys building complete all as specified and directed. |
| 15 | M&L for 5 mm thick cement plaster in cement mortar 1:3 on concrete or brick surface and finished even and smooth w/o using extra cement as in ceiling complete all as specified and directed. |
| 16 | M&L for preparing surfaces of new plaster Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified and directed. |
| 17 | M&L for preparation of new surface and applying two coat of distemper on wall incl Priming plastered and other surfaces with alkali resistant priming paint over a coat of wall care putty complete all as specified and directed. |
| 18 | M&L for preparation of new surface and applying three coat of white wash on ceiling, complete all as specified and directed. |
| 19 | Removing plant including roots by dismantaling of brick work PCC/RCC including necessary scaffoilding any type in any location/position i.e roof , parapet wall near pipes etc and applying acid after removing roots for preventing the regrowth and making good of disturbed portion using PCC 1:2:4 type B0 & 10mm thick plaster in CM 1:3 size of disturbed portion 150mm x 150mm x 200mm complete all as specified and directed. |
| 20 | M&L for exterior ( out door) wall tiles size 350mm x250mm x 7mm to 8mm thick/450mmx30mm0x7mm to 8 mm thick on vertical surfaces, jointed in neat cement slurry and pointed with coloured cement to match with colour tile etc including 15mm thick of cement plaster (1:4) incl WPC ( make/design /pattern as approved by GE Including taking down wall tiles and romove debris from defence land complete all as specified and directed. |
| 21 | Demolition of cement concrete (unreinforced) in ground floor and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 22 | M & L for 75 mm thick PCC 1:3:6 type C2 (using 40mm graded stone aggregate) as in Plinth Protection including making joints & filling with sand bitumen mastic complete all as specified and directed. |
| 23 | S&F in repair factory made SFRC man hole / drain cover (Grade M-25) heavy duty cover slab in rectangular shape of size as required, 80 mm thick incl MS sheet 2 mm thick all around the cover including demolition of cover, complete all as spefcified and directed. |
| 24 | S&F precast machine pressed PCC interlocking paver block of 60 mm thickness, M-35 grade of any shape and size confirming to IS -15658-2006 with grey cement and pigment as approved and 80mm thick plain cement concrete, type D-2, 1:4:8, (using 40mm graded stone aggregate) as in sub base flooring, surface finished even including dismantling old interlocking pave block complete all as specified and directed. |
| 25 | Taking out of APP modified water proofing membrane including mud puska complete on roof surface and surface properly cleaned by wire brush including removing of debries/domolished material obtained from roof out from defence land complete all as specified and as directed. |
| 26 | M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and directed by Engineer-in-Charge.:-(a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface.(b) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm.(c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc.(d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame.(e) Including 10mm thick rendering with 1:4 using WPC.(f) Painting with two coats of water proofing paint with aluminium finish. (g) PCC 1:2:4 type B0 (using 12.5mm graded aggregate) roof kerbs, benching rounded or chamfered on edge including rounded or chamfered edges with necessary form work etc completeNote:- This treatement shall be done by the approved authorized applicators and guarantte of treatement shall be for 10 years. |
| 27 | M&L PCC 1:2:4 type B1 using 20mm graded aggregate mixed with water proofing compound as per manufacturer instructions laid as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smooth without using extra cement up to four stories complete all as specified and directed. |
| 28 | M&L for guiniting work to RCC work in coloumn, chajjas, balconies, slabs, landings etc by removing loose, concrete, incl removing rust with short blasting and cleaning of surface with wire brush and applying epoxy treatment to rusted reinforcement and including S&F welded wire mess fabric or wire not less than 95x95x3mm adhesive plaster grade for concrete admixture and providing guniting pressure 2.00/2.50 Kg/Sq cm with admixture 1 part of cement and 3.50 part of sand and thickness 50mm average and making the surface even and smooth including necessary formwork and 10mm thick with CM 1:4 plaster over repaired surface with WPC complete all as specified and directed. |
| 29 | S & F in repair 25 mm dia Stainless steel curtain rod including all necessary fixing arrangement like clamps, end brackets, end to end bracket complete all as specified and directed. |
| 30 | S&F as in repair Rotational moulded PVC water tanks of 500 Ltr capacity, cylindrical vertical with closed top hoisted and fixed in postion including complete all as specified and directed directed. |
| 31 | Disconnecting existing tanks capacity exc. 250 ltr but n.exc 500 ltr, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. Cleaning and removing all scale and dirt, etc, from tanks capacity exc. 250 ltr but n.exc 500 ltr and from mouths of circulating pipes, etc complete all as specified and directed. |
| 32 | Dismantling to Stone slabs and tiles of any description or thickness in floors, aprons etc, and including removal upto 20 km from premises (defence land), complete all as specified and directed. |
| 33 | M&L for Rubber moulded chequered tile glosy finished Size 30cm x 30cm x 25mm thick, machine pressed; set jointed and pointed in neat cement slurry in floors, with grey cement and color pigment and cut and polished laid over including 15 mm Screed bed or bedding layer of CM 1:4, complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 08, 2026
11:30 IST
Tender Published
Tender notice published.
TodayAug 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 21 daysSep 01, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 24 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender