BOQ
| Sl. No. | Item Description |
| 1 | Surface dressing n.exc. 15 cm deep in soft loose soil complete all as specified and directed. |
| 2 | Demolition of brick work masonry built in cement mortar or cement lime mortar complete all as specified and directed. |
| 3 | Excavation in trenches n.exc. 1.5m deep & n.exc. 1.5 m wide for foudation etc. and getting out in Hard and dense soil complete all as specified and directed. |
| 4 | M& L for PCC 1:3:6 type C2 (40mm aggregate) in surface channels and drain walls or retaining walls, any thickness, size or shape including pilasters, but tresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 5 | M & L for Brickwork with subclass `B' bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 6 | M&L MS rolled steel beam, Joist, channel, Angles, tee secion of Gde Fe 410W/ E 250 quality A fixed independently without connecting plates etc complete as directed. |
| 7 | S&F Roof trusses (framed), trussed, purlins, crane gantries, rails andfastenings and heavy bracket framing Gde Fe 410W/ E 250 quality A (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. truing up and fixing complete as directed. |
| 8 | M & L for pre galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wll fixed with self tapping screws as specified including taking down old unserviceable sheets complete all as specified and directed. |
| 9 | M & L for hard core of broken stone aggregate guage exce 63mm but not exce 100mm deposted spread and levelled in layers n exc 15 cm thick watered and well rammed to true surfaces complete all as specified and directed. |
| 10 | M&L cement concrete 1:4:8 type D2, using 40m graded aggregate in sub floor,100 mm thick all as directed. |
| 11 | M& L 100mm thick cement concrete type B-2, 1:2:4 (40mm graded aggregate) complete all as specified and directed. |
| 12 | M & L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cmthick, spread, levelled and rammed including watering complete all as specified and directed. |
| 13 | M&L for rendering 15mm thick in cement mortar 1:4 brick work or concrete surfaces with WPC finished even and smooth using extra cement as specified. |
| 14 | M & L for preparation of newly plastered surface of walls and applying three coats of white wash complete all as specified and as directed. |
| 15 | M & L for preparation of new or previously untreated steel surface of any description over 10CM in width or girth not otherwis described and two coat of synthetic enamel paint over one caot of red oxide primer complete all as specified and directed. |
| 16 | M&L for preparing surfaces plastered or unplasted surface of wall by applying two coat of cement base paint over a coat of primer all as specified and directed. |
| 17 | M & L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 18 | M & L for TMT bar 5 mm dia and upto 10mm dia as in stirrups complete all as specified and directed. |
| 19 | M&L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished surfaces of concrete in flat complete all as specified and directed. |
| 20 | M&L for 50 mm thick fine sand cushioning under paver block, complete all as directed. |
| 21 | M&L for rendering 15mm thick in CM 1:6 brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. |
| 22 | M&L for 75 mm thick cement concrete (1:3:6) type C-2, using 40mm graded crushed stone aggregate as in plinth protection, surfaces finished even and fair without using extra cement complete all as specified and as directed. |
| 23 | M & L for RCC type B1 1:2:4 (20 mm graded aggregate) columns pillars, piers, posts and struts complete all as specified and directed. |
| 24 | Returning filling in trenches including spreading, levelling, watering and well ramming in layers n exc 25cm each in soils complete all as specified and directed. |
| 25 | Removing excavated rock exc 1.5 KM but n.exc 5 km and depositing where as directed. |
| 26 | M&L for PCC (1:3:6) type C2 as in foundation etc complete all as specified and directed. |
| 27 | M&L brick work with sub-class 'A' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 28 | M&L form work to sides of Retaining wall etc for fair finished surfaces complete all as specified and directed. |
| 29 | M&L for Keyed pointing to brick walls in CM 1:3 complete all as specified and directed. |
| 30 | M&L for Flush pointing to brick walls in CM 1:4 complete all as specified and directed. |
| 31 | M&L for preparation of new wall surfaces & applying two coats of cement base paint over primer complete all as specified and directed. |
| 32 | M & L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces finished fair and even without using extra cement. |
| 33 | M & L for RCC type B1 1:2:4 (20 mm graded aggregate) foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 34 | M & L for RCC type B1 1:2:4 (20 mm graded aggregate) plinth Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 35 | M&L for PCC D2 type (1:4:8) using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 36 | M&L PCC 100 mm thick, type C-2, 1:3:6 (40mm graded aggregate) as in sub-base etc complete all as directed. |
| 37 | M&L for machine pressed coloured precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade, finished with grey cement and pigment, complete all as directed. |
| 38 | M&L, for cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in coping of parapets and or roof kerbs on roof chamfered on edge incl troweling slightly complete all as specified and directed. |
| 39 | M&L for cement concrete 1:3:6, type C-1 using 20 mm graded stone aggregate as in copings, band, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. |
| 40 | Supply only integral water proofing compound. |
| 41 | M&L for 15 mm thick cement plaster in CM 1:4, on brick surface finished even and smooth without using extra cement complete. |
| 42 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 43 | M&L for point wiring with PVC insulated, unsheathed cable single core multistranded copper conductor FRLSH cable 1.5 sqmm size, 1100V grade, drawn into and including PVC rigid concealed conduit medium grade (ISI marked) including PVC unsheathed cable single core copper FRLSH conductor 1.5 Sqmm as continuous earth wire and including pressed MS sheet sunken box 1.63 mm thick with 3 mm thick laminated bakelite sheet all as specified :-One light / fan / call bell point controlled by one, one way switch. |
| 44 | All as per Ser item No 43.00 above but for 6 amps socket on independent board |
| 45 | All as per Ser item No 43.00 above but for 6 amps socket on same board |
| 46 | All as per Ser item No 43.00 above but with 2.5 sq mm cable for 15 amps switch socket combination outlet on independent board complete all as specified and directed. |
| 47 | Supply & fixing switch piano flush type single pole one way 6 Amps all as specified. |
| 48 | Supply & fixing socket outlet 6 Amp flush button type all as specified. |
| 49 | Supply & fixing switch piano flush type single pole 16 Amps. |
| 50 | Supply & fixing socket outlet 6 pin 6/16 Amps multi type. |
| 51 | M&L ceiling rose surface bakelite 65 x 50 mm three terminals complete all as specified. |
| 52 | Supply & fixing lamp holder PVC, insulated body with back plate suitable for batten fittings including LED lamp 9W all as specified. |
| 53 | Supply & fixing of 14 Watt Batten luminaire with Polycarbonate Housing with high quality extruded polycarbonate diffuser. The luminaire should have a CRI > 80 and CCT of 6500K. The luminaire shall be compliant with IP20 and IK02 classification. Luminaire shall be designed to emit at least 2100 nominal lumens and an outstanding System efficacy of at least 150 lumen/watt and maximum system wattage of 14 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 50k burning hours @ design ambient temp 45 deg C. The electronic driver used shall have a power factor >0.95 and THD <15% and suitable for an operating voltage range of 140-270V AC. Manufacturer shall have in house lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. |
| 54 | S & F SITC of high-quality integrated LED Street Light with a minimum system lumen of4750 Lm and system wattage not exceeding 45W with a nominal efficiency 105 lumen/watt. CCT of 5700K with SDCM of < 5 and CRI >70. The housing should be of non-corrosive high-pressure die-cast aluminum with high efficiency LEDs as lighting source and lens embedded PC cover having TOP Opening seperate driver compartment with IP66 protection and impact resistance of IK07 with PF > 0.95. Lifetime of 50K hours @L70. The Luminaire should have Powered by integral, Isolated LED electronic driver (SMPS based constant current supply) with lower THD, Output Open / Short Circuit protection, Phase to Phase protection (Operation at 440 V AC), Over Voltage protection, Surge Voltage protection upto 4 kV.Manufacturer shall have in house lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/ULaccredited lab to verify above parameters complete all as specified and directed. |
| 55 | Supply and fix Sheet metal DB,double door, SPN 8 way for MCB, 240 volt with , neutral bar / connectors suitable copper thimbles , lugs etc complete all as specified and directed. Note : Distribution boards should be Double Door design with IP-54 and IK-08 rating as per IEC 61439-3 with 100 Amp fully insulated copper busbars, insulated neutral bar, earth bar and cable ties for cable management. Distribution board should be supplied with door earthing, prefitted masking sheet, reversible doors and pan assembly for easy installation. Must have possibility of converting lock to panel lock. All 3 Phase horizontal distribution boards should have the provision to convert the distribution boards to Per Phase Isolation Distribution Board at site. |
| 56 | S & F MCB TPN, 240 volts, 40 to 63 Ampere, rupturing capacity 10 KA, ‘C’ curve type MCB should be ISI marked as per IS/IEC 60898-12002 with “C” Curve Characteristics. Should have bi-connect terminals on the bottom terminals for looping and should have 35 sq mm termination capacity on both terminals with insulated sliding shutters for making it IP-20 protected & with two position DIN Rail Clamp for easy mounting. |
| 57 | Supply & Fixing MCB single pole, 240 volts, 6 to 32 Ampere, rupturing capacity 10 KA, ‘C’ curve type. MCB should be ISI marked as per IS/IEC 60898-12002 with “C” Curve Characteristics. Should have bi-connect terminals on the bottom terminals for looping and should have 35 sq mm termination capacity on both terminals with insulated sliding shutters for making it IP-20 protected & with two position DIN Rail Clamp for easy mounting. |
| 58 | Earthing with and including GI earth plate electrode 6 mm thick of size 600 mm x 600 mm with 25 mm x 4 mm GI strip earthing lead complete all as shown in electrical plate No. 3 and as specified in SSR Part-I specifications. |
| 59 | Supply, errection, testing and commissioning of 15 Mtr high mast system , continuously tapered , polygonal cross section type made of conforming to IS 2062 (E250), hot dip galvanised as per IS 4759/IS 26293 sectioned of thickness bottom and middle 4 mm and top section 3 mm, of dimension top 150mm and bottom 400 mm, not less than 20 sided manufactured from Hot rolled MS plates as per BSEN 10025, galvanized complete capable of dynamic wind load bearing capacity as per IS 875 (Part-3) , with all it's accessories including head frame pully assembly, 2/3 point suspension system with stainless steel wire rope 6 mm dia 7/19 gauge, breaking load capacity 2300 Kg double drum winch, galvanized lantern carriage ring of dia 900 mm suitable for connecting 6/8 numbers flood light fittings, connecting cables with accessories, lightning arrester, aveation obstruction lights, integral power tool with 3 ph 3 HP induction motor with reversible operation, single speed 960 RPM, incl earth work and foundation, bolts and its accessories complete all as specified and directed by EIC including with following :- (a) Design and casting of suitable shallow foundation with M-20 concrete as per IS 456for the High mast considering the safe soil bearing capacity at site as 10 Ton per square meter at 2 m depth, design factor of safety 1.2, considering wind speed (km/hr) is 160 (IS 875, 1987) and depth of foundation as per height of high mast pole and minimum 12 Nos of foundation bolts (dia minimum 25 mm).(b) Aviation obstruction lights with two numbers of LED light fittings complete. |
| 60 | M&L for LED flood light luminaire 1 x 250 watt , minimum 130 lm/W efficacy, CCt5700K, symmetrical type, with pressure die cast aluminium housing (IP-66) including mounting bracket, nuts/bolts/washers and with toughened glass and suitable mounting arrangement of suitable size complete. |
| 61 | Supply Install, commissioning and testing Feeder pillar panel, CPRI Approved & conform to IS 8623/IEC 61439, factory made, double door, cubical and pedestal type, compartmentalised design, back door fixed type, fabricated out of 3.15 mm thick CRCA steel sheet, weather/dust/vermin proof, IP 65 protection, suitable spaced totally enclosed in chamber, earthing arrangement, locking arrangement with two No lock with duplicate key duly painted with powder coated paint and providing the following items incl connection of all incoming and outgoing cables using suitable size lugs and glands, danger notice board, panel to be embedded in PCC block, Earthing arrangement complete in all respect all as specified & directed by EIC including comprising of following items :- (i) MCCB 63 A, 4 pole, 415 Volts, 25 KA breaking capacity - 01 Nos(ii) Power Contactor 3 pole, AC, 70 Amps, 50 Hz, ML type. - 01 Nos(iii) Timer switch, light sensing type(auto operatiion), - 01 Nos(iv) Multifunction meter with display parameters for voltage, ampere, PF etc - 01 No (v) Indication lamp (R,Y,B), LED type, with toggle switches - 01 Set. |
| 62 | Supply and lay LT XLPE under ground cable, armoured, heavy duty , XLPE insulated and PVC sheathed, 1100 volts grade with aluminium conductors, multistranded, ISI marked including suitable cable lugs, cable gland, jointing materials etc laid in trenches, ducts, on floor/wall complete all as specified and directed by EIC of following size 4 core x 10 sqmm complete all as specified and directed. |
| 63 | Excavation in trenches in soft/lose soil not exceeding 1.5 Mtr wide and not exc 1.5M depth for laying of UG cables and getting out all as specified and directed. |
| 64 | Returning, filling, including spreading, levelling, watering and well ramming in layers not exc 25cms thick of soil complete all as specified and directed. |
| 65 | M & L river sand in trenches as cable cushioning 8 cm below the cables and 15cm above the cable which is to be punned down to 10m all as specified and directed. Only punned thickness will be measured. |
| 66 | Removing the surplus excavated materisl/soil to a distance not exc 50Mtrs and depositing, where directed at a level not exceeding 1.5 Mtr above the starting point all as specified and directed. |
| 67 | Supply and lay burnt bricks sub class 'B' standard size laid across the cable in trenches as protection to the cable all as specified and directed. |
| 68 | Supply and laying 80 mm bore GI tube light grade in trenches and passing through the culvert/road complete. |
| 69 | S&F loop in loop out thermo plastic cable junction box size 250 x 200 x 100mm (inside dimension) dust proof (IP-65) suitable for 3 phase, cable gland and cable lugs, epoxy connector/Terminal block of suitable size with 6 Amp, SP MCB-1 No. for control circuit, IS 14772/IS 8623 as applicable complete all as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 08, 2026
11:30 IST
Tender Published
Tender notice published.
TodayAug 27, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysSep 03, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 26 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender