Tender For Construction Of Open Well With Pump Room At Redikuppam In Vikkravandi Town Panchayat
Tender Value
5 Lakhs
Estimated cost
Bid Submission
13 Aug 2026
5 days left
EMD
5000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Villupuram → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Construction Of Open Well With Pump Room At Redikuppam In Vikkravandi Town Panchayat
BOQ
| Sl. No. | Item Description |
| 1 | Conducting Geophysical survey, quality and quantity test and transportation charges etc, (This includes labour charges in the field, rent of the vehicle for reaching the place, rent of the instrument and excluding charges for the geologist) |
| 2 | Drilling of Borewells anywhere in Tamilnadu including transportation from one place to another with in Tamilnadu in alluvial soil sedimentary strata of clay and sand stone shale pebbles boulders etc. By first taking a pilot bore of 140 mm/150mm dia and then enlarging to 200mm dia direct or reverse rotary mud circulation method using rotary rigs fuel, labour and drilling bentonite and water required for drilling at site including construction of mud pit. |
| 3 | Earth work for open well excavation complying with reievant clauses of T.N.D.S.S. Well sinking and with lead upto 10 metre in Hard stiff clay, stiff black coton soil, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders and hard gravely soil First depth of 2 metre including as per standard specification Ist Depth of 2m (om-2m)-1x131.47=131.47 |
| 4 | Open well excavation complying with reievant clauses of T.N.D.S.S. well sinking and with lead upto 10 metre in Soft Disintegrated Rock Not Required Blasting - First depth of 2 metre including as per standard IInd Depth of 2m (2m-4m)-2x202.56 = 405.12specification. |
| 5 | Open well excavation complying with reievant clauses of T.N.D.S.S. well sinking and with lead upto 10 metre in Medium rock and dense medium rock not requring blasting - First depth of 2 metre including as per standard specification. IIIrd Depth of 2m (4m-6m)-3X326.15=978.45 |
| 6 | Open well excavation complying with reievant clauses of T.N.D.S.S. well sinking and with lead upto 10 metre in Medium rock and dense medium rock not requring blasting - First depth of 2 metre including as per standard specification. V th Depth of 2m (8m-10m) 5X326.15=1630.75 V th Depth of 2m (8m-10m) 5X326.15=1630.75 VIth Depth of 2m (10m-12m) 6X326.15=1956.90 |
| 7 | Open well excavation complying with reievant clauses of T.N.D.S.S. well sinking and with lead upto 10 metre in Medium rock and dense medium rock not requring blasting - First depth of 2 metre including as per standard specification. VIIth Depth of 2m (12m-14m)8X326.15=2609.20 |
| 8 | Open well excavation complying with reievant clauses of T.N.D.S.S. well sinking and with lead upto 10 metre in Medium rock and dense medium rock requring blasting - First depth of 2 metre including as per standard specification.VIIIth Depth of 2m (14m-16m) 10X487.98=4879.80 |
| 9 | Open well excavation complying with reievant clauses of T.N.D.S.S. well sinking and with lead upto 10 metre in Medium rock and dense medium rock requring blasting - First depth of 2 metre including as per standard specification.IXth Depth of 2m (16m-18m) 12X487.98=5855.76 |
| 10 | Open well excavation complying with reievant clauses of T.N.D.S.S. well sinking and with lead upto 10 metre in Medium rock and dense medium rock requring blasting - First depth of 2 metre including as per standard specification. Xth Depth of 2m (18m-20m) 14X487.98=6831.72 |
| 11 | Earth work excavation for foundation and depositing on bank with in the initial lead of 10m and a lift of 2m in hard stiff clay, stiff block cotton, hard red earth, shales, murram, gravel, stoney earth and earth mixed with small size boulders etc. complete. complying with std. specifications.SS 20 B |
| 12 | Plain Cement concrete of mix 1:4:8 (One part of cement four part of sand eight part of aggregates) using 40mm gauge hard broken including cost conveyance of all materials to site including labour charges, transporting and placing in position including shoring, strutting forming protective bunds, cofferdams bailing out of water labour for mixing compacting, finishing and curing, working at depths, tools and plants and incidental charges such as sheeting, shoring and bracing and their subsequent removal etc., complete as per standard specification. |
| 13 | Supplying & Erecting centering for sides & soffiots including necessary supports & strutting upto 3.29m height for plane surfaces in all floors with all cross bracings using mild steel sheets of size 90 x 60cm & 10 gauge stiffened, welded with steel angle of size 25 x 25 x 3mm for boarding laid over silver oak joists(Country wood) of size 10 x 6.5cm spaced @ about 90cm c/c and supported by casurina props of 10 - 13cm dia. spaced @ 75cm c/c etc., complete complying with standard specifications and as directed by the departmental officers. Rate for 10m2.for the following items.(RCC floor slab, roof slab, Rectangular/ square, Tee/ Ell beams, Lintels, staircase waist slabs, Landing slabs, Landing beam, Portico beam etc., ). Curved Surface Plain Surface |
| 14 | Reinforced cement concrete 1:1½:3 (one part of cement, one point five part of sand and three part of course aggregate of 20mm size hard broken stone) for the following items. The rates excluding the cost of stone for the following items. The rates excluding the cost of supplying, fabricating and placing in opposition of TMT Rod for reinforcement and centering, strutting & shuttering, but including cost of mixing, placing the concrete in position, vibrating, consolidating, finishing and curing the concrete etc., complete and as directed by the Engineer-in-charge. |
| 15 | Supplying and fabricating and placing in position steel reinforcement using TMT rods for all RCC works as per the design given including cost of Steel and binding wire etc, complete in all floors complying with standard specification using TMT or RTS rods. |
| 16 | Brick Work in Cement Mortor 1:5 Mix (one cement, five sand) using new best II Class Bricks of size 9 ” x 4 3/8 “x 2 3/4 ” from approved quarry including cost and conveyance of all materials to site. Loading and unloading charges and labour charges for mixing, laying and curing etc. complete. Complying with std. specifications. |
| 17 | Weathering Course with broken brick jelly 20mm size pure slacked lime over R.C.C. roof slab the preparation of 32:12.5 for required depth and slope etc. complete. |
| 18 | Finishing the top of roof with one course of machine pressed tiles 23 C.m x 23 C.m x 2 C.m size using cement mortor 1:3 mix mixed with 2% by weight of Crude Oil and pointing with Cement Mortor 1:3 mix Cost of all materials and labour charges and brick jelly concrete etc., complete as per standard specifications. |
| 19 | Supply, fabricating & fixing in position of M.S door of size 0.0.90 x 2.10m. The outer frame will be 25 x 25 x 3mm angle, the side frame with outer bars and M.S Sheets 1.60mm thick 20gauge MS sheet with necessary hinges, tower bolt, aldrop length 30mm and hold fast etc., complete complying with standard specifications. |
| 20 | Supply, fabricating & fixing in position of M.S window outer frame will be 25 x 25 x 3mm angle, the side frame with outer bars and M.S Sheets 1.60mm thick 20gauge MS sheet with necessary hinges, tower bolt, aldrop length 30mm and hold fast etc., complete complying with standard specifications. |
| 21 | Supplying and fixing of M.S.Grill of approved design for grill using necessary mild steel flats for inner and outermembers which should be fixed to window frames inclusive of priming coat of best approved quality red oxide primer etc., complete complying with standard specifications |
| 22 | Plastering with cement mortar 1: 5 mix to 12mm thick including cost and conveyance of all materials to site including curing etc.,complete as per standard specification – 10m2 |
| 23 | Painting Two Coats on new Iron works with best synthetic enamel paint of approved colour and quality – 10m2. |
| 24 | Painting the new walls two coats over one coat of priming with best Emulsion paint of approved colour and quality including preparation of surface and finishing neatly etc., complete complying with standard specification and as directed by the department officers etc., complete complying with standard specifications. |
| 25 | Plain Cement Concrete 1:2:4 (one cement, two sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers. |
| 26 | Wiring with 2 x 1.5 sq.mm. (22 / 0.3 ) PVC insulated single core unsheathed copper conductor cable of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colour with continuous earth wire connection of 14 SWG TC wire for open PVC light point / fan point (for electronic regulator) SD16 |
| 27 | Wiring with 2 x 4 sq.mm. (56 / 0.3) PVC insulated SC unsheathed copper conductor cable of 1100V grade in suitable heavy gauge MS conduit pipe on wall and ceiling with MS accessories with 150mm x 100mm x 75mm MS switch box in flush with wall with 3mm thick hylum sheet for 15A 3pin non interlocking flush type CS plug with painting suitable colour with continuous earth wire connection of 14 SWG TC wire for open power plug point SD14 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 08, 2026
11:30 IST
Tender Published
Tender notice published.
TodayAug 13, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 13, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer