Tender for Repair To Wiring, Rewinding Fans And Geysers In Sector 31, 47 And 28 Under Ge (Af) Mc Chandigarh
BOQ
| Sl. No. | Item Description |
| 1 | M&L for Concealed Point wiring using stranded copper conductor FRLS cable of size 1.5 Sqmm, PVC insulated Unsheathed complete in & including non metallic rigid UPVC concealed medium grade conduit, white in colour including all fittings and accessories, using GI Sheet 0.8 mm thick terminal boxes with outer modular frame and inner cover modular plate of suitable size for mounting of modular switches, sockets, fan regulators etc fastened with chromium plated screws and 1.5 sqmm PVC insulated stranded copper conductor FRLS cable as continues earth wire connected to common earth dolly complete for One light/fan point controlled by one switch including taking down point wiring and making good disturbed surface to match with the existing finish (i.e plastering, one coat of putty and two coates of OBD paint) complete all as specified and directed. |
| 2 | All as per Srl item No. 1.00 here-in-before but One 3-pin socket outlet 5 Amp on independent board. |
| 3 | All as per Srl item No. 1.00 here-in-before but One 3 pin socket outlet 5 Amp on same board. |
| 4 | All as per Srl item No. 1.00 here-in-before but One light point controlled by 2, two switches. |
| 5 | All as per Srl item No. 1.00 here-in-before but One bell point controlled by one switch. |
| 6 | All as per Srl item No. 1.00 here-in-before but with 2.5 Sqmm copper conductor cable and 2.5 sqmm PVC insulated standard copper conductor complete FRLS cable as continuous earth wire all as specified for One 3 pin socket outlet 15 Amp on independent board. |
| 7 | M&L for Concealed Point wiring using stranded copper conductor FRLS cable of size 1.5 Sqmm, PVC insulated Unsheathed complete with universal colour code in existing steel/PVC conduit and using new GI Sheet 0.8 mm thick terminal boxes with outer modular frame and inner modular cover plate of suitable size for mounting of modular switches, sockets, fan regulators etc fastened with chromium plated screws and 1.5 sqmm PVC insulated stranded copper conductor FRLS cable as continues earth wire connected to common earth dolly complete for One light/fan point controlled by one switch including taking down point wiring and making good disturbed surface (i.e plastering, one coat of putti and two coates of OBD paint) complete all as specified and directed. |
| 8 | All as per Srl item No. 7.00 here-in-before but One 3-pin socket outlet 5 Amp on independent board. |
| 9 | All as per Srl item No. 7.00 here-in-before but One 3 pin socket outlet 5 Amp on same board. |
| 10 | All as per Srl item No. 7.00 here-in-before but One light point controlled by 2, two switches. |
| 11 | All as per Srl item No. 7.00 here-in-before but One bell point controlled by one switch. |
| 12 | All as per Srl item No. 7.00 above, but with 2.5 Sqmm copper conductor cable and 2.5 sqmm PVC insulated standard copper conductor complete FRLS cable as continuous earth wire all as specified for One 3 pin socket outlet 15 Amp on independent board. |
| 13 | To attend electrical complaints of any nature pertaining to internal electrification, ceiling Fan/ Geyser/ exhaust fan or fault finding, short circuiting, No light of any nature any where reported by users, bldg light, main distribution board and connected wiring/control LT cables of size of any type and any location and locating the fault and rectification of the fault and replacing the burnt out items as per site requirement incl making connection and testing after completion of job complete all as specified and as directed by Engr-in-Charge.Note :- (i) The T&P items and testing lamp shall be provided by the Contractor at his own cost.(ii) Any spare required for rectification/replacement will be paid under supply only items. (iii) The Contractor or his authorized representative (with mobile phone) shall remain in the complaints cells of GE (AF) MC Chd located in Sec 47 daily for collection of complaint slip from the concerned JE E/M.(iv) Contractor will supply following well experienced and well conversant team against (Electrician - 1 Nos having experience of minimum 3 years with helper -01 Nos) GENERAL NATURE COMPLAINTS at 1000 Hrs to 1800 Hrs & URGENT NATURE COMPLAINTS –24 Hrs at a time for attending elect complaints all working days including Sunday & all Holidays. (v) The date/time and nature of complaint URGENT or GENERAL shall be indicated on each complaint slip by JE E/M.(vi) Replacement of the items shall be measured and paid seprately under supply only items . (vii) All complaint slip shall be returned by the contractor in the complaints cells of GE (AF) MC Chd located in Sec 47 daily or same day upto 1700 Hrs to the JE E/M or his representive after necessary repair/ replacement have been carried out and signature of the user on the complaint slip. It is responsibility of the contractor for rectification of complaint to be satisfied by the users.(viii) Monthly means equal to 26 days excluding sunday and gazetted holidays. |
| 14 | Supply only in replacement 04 feet 20 Watt LED MS White powder coated Batten with decorative end cap complete with retrofit PC Type, complete all as specified and directed. |
| 15 | Supply only in replacement 02 feet 10 Watt LED MS White powder coated Batten with decorative end cap complete with retrofit PC Type, complete all as specified and directed. |
| 16 | Supply only in replacement 01 feet 5 Watt LED MS White powder coated Batten with decorative end cap complete with retrofit PC Type, complete all as specified and directed. |
| 17 | Supply only in repair LED Bulk head Luminaire made of pressure die cast aluminium hosing with protected diffuser 9/10 watt system wattage, colour temp, 6500K, PF >0.9 complete all as specified and directed. |
| 18 | Supply only in replacement of wall mounted fittings with ABS housing and clear polycarbonate cover including retrofit LED bulb 06/09 watt including making connection with flexible copper 3 core cable 0.5 Sqmm from connector/ ceiling rose to fitting complete all as specified and directed. |
| 19 | Supply only in repair LED bulb 07/09 Watt retrofit type complete all as specified and directed. |
| 20 | Supply only in repair LED street light fitting 30W powder coated, pressure die cast aluminium body and polycarbonate cover with individual LED lense having colour temperature, 6500 +/- 500, PF >0.90 having system efficiency 2400 lumen with GI Braket all accessories such as connection, nut and bolt etc, complete all as specified and directed. |
| 21 | Supply only in replacement of surface mounting 36 watt LED of size 2X2 feet slim ceiling light with extured aluminium housing powder coated, milky diffuser operating voltage 120v-280v, PF >0.95, inbuilt short circuit protection and surge protection, soft and uniform light distribution system lumen more than 100LM/W, CRI>80, integrated constant current electronic driver all as specified and directed. |
| 22 | Supply only in replacement of recess mounting 36 watt LED of size 2X2 feet slim ceiling light with extured aluminium housing powder coated, milky diffuser operating voltage 120v-280v, PF >0.95, inbuilt short circuit protection and surge protection, soft and uniform light distribution system lumen more than 100LM/W, CRI>80, integrated constant current electronic driver all as specified and directed. Please Enable Macros to View BoQ information |
| 23 | Supply only in replacement of recess mounting 36 watt LED of size 2X2 feet slim ceiling light with extured aluminium housing powder coated, milky diffuser operating voltage 120v-280v, PF >0.95, inbuilt short circuit protection and surge protection, soft and uniform light distribution system lumen more than 100LM/W, CRI>80, integrated constant current electronic driver all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender