Tender For Repair And Maintenance Of Obsolete Aluminium Wiring And Fittings Of ( G Branch Block) At Adm Block Under Ftr Hq Pb (Sh-Ii Medical, Recruitment Branch And Signal Center Block)
Tender Value
2 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
5 days left
EMD
4003
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Maintenance Of Obsolete Aluminium Wiring And Fittings Of ( G Branch Block) At Adm Block Under Ftr Hq Pb (Sh-Ii Medical, Recruitment Branch And Signal Center Block)
BOQ
| Sl. No. | Item Description |
| 1 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. GROUP -C |
| 2 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required GROUP -C |
| 3 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulatedcopper conductor, single core cable in surface/recessed steel conduit as required.(a)2 x 1.5 sq. mm + 1 x 1.5 sq. mm |
| 4 | (b) 2 x 4 sq. mm + 1 x 4 sq. mm |
| 5 | Supplying and drawing following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 3 x 1.5 sq. mm |
| 6 | (b) 3 x 4 sq. mm |
| 7 | Supplying and fixing of 20 mm of medium class PVC conduit along with accessories insurface/recess including cutting the wall and making good the same in case of recessed conduit asrequired. |
| 8 | Supplying and fixing of 25 mm of medium class PVC conduit along with accessories insurface/recess including cutting the wall and making good the same in case of recessed conduit asrequired. |
| 9 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.(a) 5/6 A switch |
| 10 | (b) 2 way 5/6 A switch |
| 11 | (c) 15/16 A switch |
| 12 | (d) 3 pin 5/6 A socket outlet |
| 13 | (e) 3 pin 15/16 A socket outlet |
| 14 | (f) Telephone socket outlet |
| 15 | (g) Bell push |
| 16 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 17 | Supplying and fixing following size/ modules, GI/PVC box alongwith modular base & cover plate for modular switches in recess etc. as required. (a) 1 or 2 Module (75mmX75mm) |
| 18 | (b) 4 Module (125mmX75mm) |
| 19 | (c) 6 Module (200mmX75mm) |
| 20 | (d) 8 Module (125mmX125mm) |
| 21 | (e) 12 Module (200mmX150mm) |
| 22 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.(a) 3 Module |
| 23 | (b) 6 Module |
| 24 | Supplying and fixing suitable size GI box with modularplate and cover in front on surface or in recess,including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 25 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 26 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 27 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). |
| 28 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of single poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 29 | Providing and fixing, 20 amp motor starter switch 2 M suitable for operation on 230 Volt, 50 Hz including connection, testing etc. complete as required. |
| 30 | Supplying and fixing one module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 18, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender