Bids Are invited for Ultrasound High End - The Equipment Should Be Top Of The Line, With The Latest Software Release. System Architecture Should Be With Digital Beam Former With Precision Beamforming And Massive Parallel Processing Like N-Sight/ Lyri
Tender Overview
Project Description
Bids Are invited for Ultrasound High End - The Equipment Should Be Top Of The Line, With The Latest Software Release. System Architecture Should Be With Digital Beam Former With Precision Beamforming And Massive Parallel Processing Like N-Sight/ Lyric For Processing Enormous Amount Of Acoustic Data Allowing Clinically Proven Imaging Technologies To Achieve Superb Tissue Uniformity All The Way Up To The Skin Line Without The Compromise Of Conventional Transmit Focus Limitations. , The Equipment Must Be Capable Of Operating In B, M, Doppler, Color Flow And Power Doppler Modes, Contrast Microbubble Ultrasound & 3D / 4D Volume Scanning, Real Time 2D Shear Wave Elastography & Fusion + Navigation Capabilities. , It Should Support Transducers With Single Crystal & Matrix Technology. Further, It Must Include A Full Array Of Measurement Andcalculation Packages. The Specific Minimum Requirements For This Equipment Are As Follows , System Should Have The Latest Technology To Eliminate Manual Focus Position And Automatically Focus The Entire Field Of View On All The Probes , The Console Should Have Height & Rotation Option , The System Shall Include At Least A 22 Hdmax / Oled Monitor With Viewing Angle Of More Than 175 Deg , The Monitor Shall Be Mounted On An Articulating Arm That Moves Side-To-Side, Forward, And Backward. , The System Should Have A Capacitive Touch Panel Of 12 Or More For Easy Use Of Routinely Used Features, Twin View. , The System Shall Have Minimum Four Integrated Active Universal Transducer Ports , The System Shall Offer An Extended Field-Of-View Imaging That Operates By Sweeping A Transducer Over The Anatomy Of Interest. This Mode Shall Build The Extended Field-Of-View In A Real-Time Manner, Showing The Image As It Builds , System Shall Have Image Management Features That Store Images By Patient And Include The Ability To Review Images From Different Exam Dates. , System Shall Support The Ability To Store Digital Data In, That Allows To Optimize Imaging Parameters Such As B Gain, Tgc, Color Gain, Dynamic Range, Speckle Reduction Levels, Doppler Gain, Doppler Base Line On Old Images & Old Loops Recalled From The Image Archive , System Shall Allow For Live Image And Archive Images Side-By-Side Or Quad Display On A Single Monitor. This Display Shall Allow Any Type Of Image – B-Mode, Color, Or Power Doppler On Either Side , Automated Shear Wave Elastography With Color Coded Adjustable Box And Quality Indicator Should Be Available In Convex, Linear Probe Also Measurement Should Be Available In Kpa & M/S Simultaneously. A Maximum Number Of 9 Or More Measurements Should Be Taken In 1 Single Frame. Offline Measurements Of Shearwave Elastography Should Be Possible. , System Should Be Capable To Quantify Liver Steatosis To Aid In Early Identification And Monitoring Of Patients With Nafld, Nash Or Ash. Units Should Be In Db/M Or Db/Cm/Mhz , System Should Have The Capability To Integrate Both Shearwave Elastography & Fat Quantification Tools For Better Workflow , System Should Have Facility For Fusion Imaging And Navigation To Combine Ultrasound Images With Mri, Ct And Pet Images With Built In Sensors & Auto Registration Feature Based On Anatomical Intelligence For End User Comfort. System Should Have Ability To Fuse Axial, Sagittal And Coronal Images. , Contrast Ultrasound Capability (Ceus) Shall Be Available. , System Should Have The Capability To Compare Previous Patient Images During Live Scan , System Should Have The Capability To Pick Micro Vessel Flow To Detect Slow And Weak Blood Flow While Maintaining The High Frame Rate And 2D Image Quality. , System Should Have The Capability To Measure The Area Of Lesions/Cyst Automatically , System Should Have An Ai Feature In Doppler Studies Which Automatically Places The Color Box By Understanding The Location And Direction Of The Vessels And Automatic Angle Correction, Pw And Baseline Adjustments As Well , System Must Have An Advanced Real-Time Ai Tool That Automatically Help To Detect Upto 9 Different Types Of Liver Lesions That Are Subtle To Naked Eyes Besides The Prominent Ones Ensuring No Lesion Is Left Undiagnosed. , The System Shall Allow For Post-Storage Image Manipulation To Provide Maximum Image Flexibility, Review And Productivity. It Shall Include The Ability To Change All Following On Recalled Old Stored Images/Loops. , Overall B-Mode Gain, Dynamic Range And Gray Scale Maps. , Overall Doppler Gain, Base Line Shift, Sweep Speed And Inverted Spectral Waveform , Anatomical M-Mode , The System Shall Provide A Display Zoom Function On Frozen Images. , The System Should Have Minimum 30,000,000 Digital System Processing Channels , The System Shall Possess The Ability To Control Speckle Through The Use Of A Speckle Reduction Algorithm That Enhances Borders,Reduces Speckle Artifact And Improves Detail And Contract Resolution In Gray Scale With Compatibility In Contrast, Color Mode, Doppler, 2D And 3D. This Feature Shall Have 5 Or More Operator Selectable Settings And Be Capable Of Displaying In Side-By-Side Mode With Non- Speckle Reduced Image. , The System Shall Provide The Ability To Scan In The Compound Imaging Mode With Up To 9 Lines On All Linear And Convex Probes , The System Shall Provide Scan Depths From A Minimum Of 2 Cm To A Maximum Of At Least 50 Cm. , System Should Have Frame Rate More Than 2800F/S , System Should Have 256 Gray Shades , B-Mode / M-Mode Imaging , The System Shall Provide The Capability For Tissue Harmonic Imaging On All Offered Transducers. , Color Flow/Bi -Directional Power Doppler/Pulse Wave Doppler , Measurements And Calculations , Measurements Should Be Possible On Frozen Images As Well As On Images Recalled From The Image Archive. , The System Shall Provide A Comprehensive Set Of Obstetrical And Gynecologic Calculations And Vascular Calculations With Summary Reports , The Device Should Store Images Onto An Integrated/External Dvd-R Multidrive And A Usb Port Storage Device , The System Shall Include At Least 1Tb Hdd To Store Images And Additional Min 240 Ssd For Image Storage And Increasing Computational Power And Overall Operational Speed. , The Device Should Store / Transfer Images In Dicom / Jpeg / Wmv / Avi Formats For Maximum Flexibility. , Dicom Connectivity Shall Be Standard , System Should Be Able To Handle Frequencies From 1-22 Mhz Or More. , 1 To 5 Mhz (+/- 2Mhz) Matrix / Xd Clear / Purewave / Single Crystal Convex Transducer For Abdominal Imaging With Shearwave Elastography With Biopsy Guide -01 Qty , 4 To 16 Mhz (+/-2 Mhz) Matrix / Xd Clear / Purewave / Single Crystal Linear For Small Parts, Breast, Vascular, Msk, Bowel, Obs, Pediatric With Electromagnetic Tracker For Fusion And Navigation; Strain & Shearwave Elastography. With Fov Of Minimum 50Mm And Shall Be Supplied With Biopsy Guide. 01 Qty , 4 To 14 Mhz (+/- 2 Mhz) Linear Probe For Dedicated Vascular And Cerebrovascular Application – 01 Qty , 5 To 24 Mhz (+/- 3Mhz) Broadband Linear (Hockey Stick) For Msk, Small Parts, Interoperative Scans -01 Qty , 3 To 9 Mhz (+/-2 Mhz) Micro Convex And Shall Be Supplied With Biopsy Guide -01 Qty , 3 To 10 Mhz (+/- 1 Mhz) Endo Cavity Transducer For Urology With Fusion Imaging And Shall Be Supplied With Biopsy Guide -01 Qty , Should Perform Preventive Maintenance (2Nos) During Warranty & If Entered Into Amc(Includes Unlimited Breakdown Calls) /Cmc (Which Will Include Spare Replacement, Breakdown Calls). Vendor To Submit Sops For Pms At The Time Of Installation/ Commissioning. This Is Mandatory Requirement. , Performance Certificates Of Iq,Oq,Pq Tests To Be Submitted At The Time Of Installation/Commissioning. , Vendor To Submit The Technical Data Sheet, Brochure Etc As A Tender Document With Reference To The Quoted Make & Model. Please Mention The Reference Page No., Etc In These Documents Against Each Technical Specifications In The Compliance. , Vendor To Submit List & Cost Of Consumables/Consumable Spares( I.E.Spares Need To Be Replaced At Regular Intervals, Maybe Quarterly/Half Yearly/Yearly Etc.) If Any. , Please Submit Pre Installation Requirements [Electrical, Hvac, Compressed Air Along With Air Pressure Mentioned), Water Requirement (Ro/Di/Distilled Water With Its Pressure, Flow Rate Per Hour) ; If Any Of The Above Is Essential] , Vendor To Provide Ups With Adequate Capacity, If Required For The Quoted Equipment. If Not Required, Vendor To Mention The Same. , Vendor To Submit Details Of Footprint Size & Weight Of The Quoted Model. , Vendor To Submit Power Consumption. , Demo Of The Quoted Model , Will Be Required If So Desired By The User, After The Opening Of The Technical Bid And Prior To Opening Of Financial Bid. This Is For Technical Evaluation. All Technical Specifications Mentioned Above To Be Mandatorily Shown In The Demo Unit. , Users/Installation List: A List Of Installations Of The Quoted Model With The Address And Contact Numbers To Be Provided. , Predispatch Inspection At Factory Will Be Required If Desired By Authorities. , Vendor To Visit The Site To Check Whether Quoted Model Can Be Accomodated In The Available Space. , Safety Requirement: It Should Follow Safety Requirement. Please Specify Certification With Certifying Agency & Country With Copies Of Certificate. , Unpacking And Shifting The Consignment To The Installation Site Is To Be Included In The Vendors Scope Of Supply. Bidder/Manufacturer/Authorized Service Provider Should Take Responsibility To Lift /Shift The Consignment From Unloading Site To The Installation Site. Unloading Site Shall Be Stores Department, Tmh. If Needed ,Bidder Has To Arrange For The Labours At No Charge To Tmh. Before Submitting The Quotation,Bidders May Visit Tmh To Know Unloading And Installation Site. , Complete Decommissioning & Dismantling Of Existing Machine With Clearing The Debris/Scrap From The Respective Site Will Be Sole Responsibility Of The Vendor If Buyback. , Training: , Local Service Support: Should Have Local Office And Service Support/Service Engineer For Attending The Breakdown Calls. Details To Be Submitted. , Response Time: Should Not Be More Than 06 Hrs From Lodging A Breakdown Complaint On Toll Free Or By Email. , Warranty- 2 Years , Cmc- Cost Per Annum Will Be Considered For All Bidders For 8 Years After Warranty (Should Include Qa Qc Annually As Per Aerb Noms.) , Back To Back Assurance To Be Taken By The Supplier From Oem To Supply Spares For Minimum 10 Years And To Be Submitted. , Penalty Clause:
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | The equipment should be Top of the Line, with the latest software release. System architecture should be with Digital beam former with precision beamforming and massive parallel processing like n-sight/ lyric for processing enormous amount of acoustic data allowing clinically proven imaging technologies to achieve superb tissue uniformity all the way up to the skin line without the compromise of conventional transmit focus limitations. | The equipment should be Top of the Line, with the latest software release. System architecture should be with Digital beam former with precision beamforming and massive parallel processing like n-sight/ lyric for processing enormous amount of acoustic data allowing clinically proven imaging technologies to achieve superb tissue uniformity all the way up to the skin line without the compromise of conventional transmit focus limitations. |
| 2 | The equipment must be capable of operating in B, M, Doppler, Color flow and Power Doppler modes, Contrast microbubble ultrasound & 3D / 4D Volume Scanning, Real time 2D Shear Wave elastography & Fusion + Navigation capabilities. | The equipment must be capable of operating in B, M, Doppler, Color flow and Power Doppler modes, Contrast microbubble ultrasound & 3D / 4D Volume Scanning, Real time 2D Shear Wave elastography & Fusion + Navigation capabilities. |
| 3 | It should support transducers with Single crystal & Matrix technology. Further, it must include a full array of measurement andcalculation packages. The specific minimum requirements for this equipment are as follows | It should support transducers with Single crystal & Matrix technology. Further, it must include a full array of measurement andcalculation packages. The specific minimum requirements for this equipment are as follows |
| 4 | System should have the latest technology to eliminate manual focus position and automatically focus the entire field of view on all the probes | System should have the latest technology to eliminate manual focus position and automatically focus the entire field of view on all the probes |
| 5 | The console should have height & rotation option | The console should have height & rotation option |
| 6 | The system shall include at least a 22” HDMAX / OLED monitor with viewing angle of more than 175 deg | The system shall include at least a 22” HDMAX / OLED monitor with viewing angle of more than 175 deg |
| 7 | The monitor shall be mounted on an articulating arm that moves side-to-side, forward, and backward. | The monitor shall be mounted on an articulating arm that moves side-to-side, forward, and backward. |
| 8 | The system should have a capacitive touch panel of 12” or more for easy use of routinely used features, twin view. | The system should have a capacitive touch panel of 12” or more for easy use of routinely used features, twin view. |
| 9 | The system shall have minimum Four integrated active universal Transducer Ports | The system shall have minimum Four integrated active universal Transducer Ports |
| 10 | The system shall offer an extended field-of-view imaging that operates by sweeping a transducer over the anatomy of interest. This mode shall build the extended field-of-view in a real-time manner, showing the image as it builds | The system shall offer an extended field-of-view imaging that operates by sweeping a transducer over the anatomy of interest. This mode shall build the extended field-of-view in a real-time manner, showing the image as it builds |
| 11 | System shall have image management features that store images by patient and include the ability to review images from different exam dates. | System shall have image management features that store images by patient and include the ability to review images from different exam dates. |
| 12 | System shall support the ability to store digital data in, that allows to optimize imaging parameters such as B Gain, TGC, Color Gain, Dynamic Range, Speckle Reduction levels, Doppler Gain, Doppler Base Line on old Images & old loops recalled from the image archive | System shall support the ability to store digital data in, that allows to optimize imaging parameters such as B Gain, TGC, Color Gain, Dynamic Range, Speckle Reduction levels, Doppler Gain, Doppler Base Line on old Images & old loops recalled from the image archive |
| 13 | System shall allow for live image and archive images side-by-side or quad display on a single monitor. This display shall allow any type of image – B-Mode, Color, or power Doppler on either side | System shall allow for live image and archive images side-by-side or quad display on a single monitor. This display shall allow any type of image – B-Mode, Color, or power Doppler on either side |
| 14 | Automated Shear Wave Elastography with color coded adjustable box and quality indicator should be available in Convex, Linear Probe also measurement should be available in Kpa & m/s simultaneously. A maximum number of 9 or more measurements should be taken in 1 single frame. Offline measurements of Shearwave elastography should be possible. | Automated Shear Wave Elastography with color coded adjustable box and quality indicator should be available in Convex, Linear Probe also measurement should be available in Kpa & m/s simultaneously. A maximum number of 9 or more measurements should be taken in 1 single frame. Offline measurements of Shearwave elastography should be possible. |
| 15 | System should be capable to quantify liver steatosis to aid in early identification and monitoring of patients with NAFLD, NASH or ASH. Units should be in dB/m or dB/cm/MHz | System should be capable to quantify liver steatosis to aid in early identification and monitoring of patients with NAFLD, NASH or ASH. Units should be in dB/m or dB/cm/MHz |
| 16 | System should have the capability to integrate both Shearwave elastography & fat quantification tools for better workflow | System should have the capability to integrate both Shearwave elastography & fat quantification tools for better workflow |
| 17 | System should have facility for Fusion Imaging and Navigation to combine Ultrasound images with MRI, CT and PET images with built in sensors & Auto registration feature based on anatomical intelligence for end user comfort. System should have ability to fuse axial, sagittal and coronal images. | System should have facility for Fusion Imaging and Navigation to combine Ultrasound images with MRI, CT and PET images with built in sensors & Auto registration feature based on anatomical intelligence for end user comfort. System should have ability to fuse axial, sagittal and coronal images. |
| 18 | Contrast Ultrasound Capability (CEUS) shall be available. | Contrast Ultrasound Capability (CEUS) shall be available. |
| 19 | System should have the capability to compare previous patient images during live scan | System should have the capability to compare previous patient images during live scan |
| 20 | System should have the capability to pick micro vessel flow to detect slow and weak blood flow while maintaining the high frame rate and 2D image quality. | System should have the capability to pick micro vessel flow to detect slow and weak blood flow while maintaining the high frame rate and 2D image quality. |
| 21 | System should have the capability to measure the area of lesions/Cyst automatically | System should have the capability to measure the area of lesions/Cyst automatically |
| 22 | System should have an AI feature in doppler studies which automatically places the color box by understanding the location and direction of the vessels and automatic angle correction, PW and baseline adjustments as well | System should have an AI feature in doppler studies which automatically places the color box by understanding the location and direction of the vessels and automatic angle correction, PW and baseline adjustments as well |
| 23 | System must have an advanced Real-time AI tool that automatically help to detect upto 9 different types of Liver lesions that are subtle to naked eyes besides the prominent ones ensuring no lesion is left undiagnosed. | System must have an advanced Real-time AI tool that automatically help to detect upto 9 different types of Liver lesions that are subtle to naked eyes besides the prominent ones ensuring no lesion is left undiagnosed. |
| 24 | The system shall allow for Post-Storage image manipulation to provide maximum image flexibility, review and productivity. It shall include the ability to change all following on recalled old Stored Images/Loops. | The system shall allow for Post-Storage image manipulation to provide maximum image flexibility, review and productivity. It shall include the ability to change all following on recalled old Stored Images/Loops. |
| 25 | Overall B-Mode gain, dynamic range and gray scale maps. | Overall B-Mode gain, dynamic range and gray scale maps. |
| 26 | Overall Doppler gain, base line shift, sweep speed and inverted spectral waveform | Overall Doppler gain, base line shift, sweep speed and inverted spectral waveform |
| 27 | Anatomical M-Mode | Anatomical M-Mode |
| 28 | The system shall provide a display zoom function on frozen images. | The system shall provide a display zoom function on frozen images. |
| 29 | The system should have minimum 30,000,000 digital system processing channels | The system should have minimum 30,000,000 digital system processing channels |
| 30 | The system shall possess the ability to control speckle through the use of a speckle reduction algorithm that enhances borders,reduces speckle artifact and improves detail and contract resolution in gray scale with compatibility in Contrast, Color mode, Doppler, 2D and 3D. This feature shall have 5 or more operator selectable settings and be capable of displaying in side-by-side mode with non- speckle reduced image. | The system shall possess the ability to control speckle through the use of a speckle reduction algorithm that enhances borders,reduces speckle artifact and improves detail and contract resolution in gray scale with compatibility in Contrast, Color mode, Doppler, 2D and 3D. This feature shall have 5 or more operator selectable settings and be capable of displaying in side-by-side mode with non- speckle reduced image. |
| 31 | The system shall provide the ability to scan in the compound imaging mode with up to 9 lines on all linear and convex probes | The system shall provide the ability to scan in the compound imaging mode with up to 9 lines on all linear and convex probes |
| 32 | The system shall provide scan depths from a minimum of 2 cm to a maximum of at least 50 cm. | The system shall provide scan depths from a minimum of 2 cm to a maximum of at least 50 cm. |
| 33 | System Should have frame rate more than 2800f/s | System Should have frame rate more than 2800f/s |
| 34 | System should have 256 gray shades | System should have 256 gray shades |
| 35 | B-Mode / M-mode Imaging | B-Mode / M-mode Imaging |
| 36 | The system shall provide the capability for tissue harmonic imaging on all offered transducers. | The system shall provide the capability for tissue harmonic imaging on all offered transducers. |
| 37 | Color flow/Bi -Directional Power Doppler/Pulse Wave Doppler | Color flow/Bi -Directional Power Doppler/Pulse Wave Doppler |
| 38 | Measurements and Calculations | Measurements and Calculations |
| 39 | Measurements should be possible on frozen images as well as on images recalled from the image archive. | Measurements should be possible on frozen images as well as on images recalled from the image archive. |
| 40 | The system shall provide a comprehensive set of obstetrical and gynecologic calculations and vascular calculations with summary reports | The system shall provide a comprehensive set of obstetrical and gynecologic calculations and vascular calculations with summary reports |
| 41 | The device should store images onto an integrated/external DVD-R Multidrive and a USB port storage device | The device should store images onto an integrated/external DVD-R Multidrive and a USB port storage device |
| 42 | The system shall include at least 1TB HDD to store images and additional min 240 SSD for image storage and increasing computational power and overall operational speed. | The system shall include at least 1TB HDD to store images and additional min 240 SSD for image storage and increasing computational power and overall operational speed. |
| 43 | The device should store / transfer images in DICOM / JPEG / WMV / AVI formats for maximum flexibility. | The device should store / transfer images in DICOM / JPEG / WMV / AVI formats for maximum flexibility. |
| 44 | DICOM Connectivity shall be standard | DICOM Connectivity shall be standard |
| 45 | System should be able to handle frequencies from 1-22 MHz or more. | System should be able to handle frequencies from 1-22 MHz or more. |
| 46 | 1 to 5 MHz (+/- 2MHz) Matrix / XD Clear / PureWave / Single crystal Convex Transducer for abdominal imaging with Shearwave elastography with Biopsy guide -01 Qty | 1 to 5 MHz (+/- 2MHz) Matrix / XD Clear / PureWave / Single crystal Convex Transducer for abdominal imaging with Shearwave elastography with Biopsy guide -01 Qty |
| 47 | 4 to 16 MHz (+/-2 MHz) Matrix / XD Clear / PureWave / Single crystal Linear for Small parts, Breast, Vascular, MSK, Bowel, Obs, Pediatric with electromagnetic tracker for fusion and navigation; Strain & Shearwave elastography. With FoV of minimum 50mm and shall be supplied with biopsy guide. 01 Qty | 4 to 16 MHz (+/-2 MHz) Matrix / XD Clear / PureWave / Single crystal Linear for Small parts, Breast, Vascular, MSK, Bowel, Obs, Pediatric with electromagnetic tracker for fusion and navigation; Strain & Shearwave elastography. With FoV of minimum 50mm and shall be supplied with biopsy guide. 01 Qty |
| 48 | 4 to 14 MHz (+/- 2 MHz) Linear probe for dedicated vascular and cerebrovascular application – 01 Qty | 4 to 14 MHz (+/- 2 MHz) Linear probe for dedicated vascular and cerebrovascular application – 01 Qty |
| 49 | 5 to 24 MHz (+/- 3MHz) Broadband Linear (Hockey stick) for MSK, small parts, Interoperative Scans -01 Qty | 5 to 24 MHz (+/- 3MHz) Broadband Linear (Hockey stick) for MSK, small parts, Interoperative Scans -01 Qty |
| 50 | 3 to 9 MHz (+/-2 MHz) micro Convex and shall be supplied with biopsy guide -01 Qty | 3 to 9 MHz (+/-2 MHz) micro Convex and shall be supplied with biopsy guide -01 Qty |
| 51 | 3 to 10 MHz (+/- 1 MHz) Endo cavity transducer for Urology with fusion imaging and shall be supplied with biopsy guide -01 Qty | 3 to 10 MHz (+/- 1 MHz) Endo cavity transducer for Urology with fusion imaging and shall be supplied with biopsy guide -01 Qty |
| 52 | Should perform preventive maintenance (2nos) during warranty & if entered into AMC(includes unlimited breakdown calls) /CMC (which will include spare replacement, breakdown calls). Vendor to submit SOPs for PMS at the time of installation/ commissioning. This is mandatory requirement. | Should perform preventive maintenance (2nos) during warranty & if entered into AMC(includes unlimited breakdown calls) /CMC (which will include spare replacement, breakdown calls). Vendor to submit SOPs for PMS at the time of installation/ commissioning. This is mandatory requirement. |
| 53 | Performance certificates of IQ,OQ,PQ tests to be submitted at the time of installation/commissioning. | Performance certificates of IQ,OQ,PQ tests to be submitted at the time of installation/commissioning. |
| 54 | Vendor to submit the technical data sheet, brochure etc as a tender document with reference to the quoted make & model. Please mention the reference page no., etc in these documents against each technical specifications in the compliance. | Vendor to submit the technical data sheet, brochure etc as a tender document with reference to the quoted make & model. Please mention the reference page no., etc in these documents against each technical specifications in the compliance. |
| 55 | Vendor to submit list & cost of consumables/consumable Spares( i.e.spares need to be replaced at regular intervals, maybe quarterly/half yearly/yearly etc.) if any. | Vendor to submit list & cost of consumables/consumable Spares( i.e.spares need to be replaced at regular intervals, maybe quarterly/half yearly/yearly etc.) if any. |
| 56 | Please submit pre installation requirements [electrical, HVAC, Compressed air along with air pressure mentioned), water requirement (RO/DI/Distilled water with its pressure, flow rate per hour) ; if any of the above is essential] | Please submit pre installation requirements [electrical, HVAC, Compressed air along with air pressure mentioned), water requirement (RO/DI/Distilled water with its pressure, flow rate per hour) ; if any of the above is essential] |
| 57 | Vendor to provide UPS with adequate capacity, if required for the quoted equipment. If not required, vendor to mention the same. | Vendor to provide UPS with adequate capacity, if required for the quoted equipment. If not required, vendor to mention the same. |
| 58 | Vendor to submit details of footprint size & weight of the quoted model. | Vendor to submit details of footprint size & weight of the quoted model. |
| 59 | Vendor to submit power consumption. | Vendor to submit power consumption. |
| 60 | Demo of the quoted model , will be required if so desired by the user, after the opening of the technical bid and prior to opening of financial bid. This is for technical evaluation. All technical specifications mentioned above to be mandatorily shown in the demo unit. | Demo of the quoted model , will be required if so desired by the user, after the opening of the technical bid and prior to opening of financial bid. This is for technical evaluation. All technical specifications mentioned above to be mandatorily shown in the demo unit. |
| 61 | User's/Installation list: A list of installations of the quoted model with the address and contact numbers to be provided. | User's/Installation list: A list of installations of the quoted model with the address and contact numbers to be provided. |
| 62 | Predispatch inspection at factory will be required if desired by authorities. | Predispatch inspection at factory will be required if desired by authorities. |
| 63 | Vendor to visit the site to check whether quoted model can be accomodated in the available space. | Vendor to visit the site to check whether quoted model can be accomodated in the available space. |
| 64 | Safety requirement: It should follow safety requirement. Please specify certification with certifying agency & country with copies of certificate. | Safety requirement: It should follow safety requirement. Please specify certification with certifying agency & country with copies of certificate. |
| 65 | Unpacking and shifting the consignment to the installation site is to be included in the vendor's scope of supply. Bidder/manufacturer/authorized service provider should take responsibility to lift /shift the consignment from unloading site to the installation site. Unloading site shall be Stores department, TMH. If needed ,bidder has to arrange for the labours at no charge to TMH. Before submitting the quotation,bidders may visit TMH to know unloading and installation site. | Unpacking and shifting the consignment to the installation site is to be included in the vendor's scope of supply. Bidder/manufacturer/authorized service provider should take responsibility to lift /shift the consignment from unloading site to the installation site. Unloading site shall be Stores department, TMH. If needed ,bidder has to arrange for the labours at no charge to TMH. Before submitting the quotation,bidders may visit TMH to know unloading and installation site. |
| 66 | Complete decommissioning & dismantling of existing machine with clearing the debris/scrap from the respective site will be sole responsibility of the vendor if buyback. | Complete decommissioning & dismantling of existing machine with clearing the debris/scrap from the respective site will be sole responsibility of the vendor if buyback. |
| 67 | Training: | Training: |
| 68 | Local Service Support: Should have local office and service support/service engineer for attending the breakdown calls. Details to be submitted. | Local Service Support: Should have local office and service support/service engineer for attending the breakdown calls. Details to be submitted. |
| 69 | Response Time: Should not be more than 06 hrs from lodging a breakdown complaint on toll free or by email. | Response Time: Should not be more than 06 hrs from lodging a breakdown complaint on toll free or by email. |
| 70 | Warranty- 2 years | Warranty- 2 years |
| 71 | CMC- cost per annum will be considered for all bidders for 8 years after warranty (Should include QA QC annually as per AERB noms.) | CMC- cost per annum will be considered for all bidders for 8 years after warranty (Should include QA QC annually as per AERB noms.) |
| 72 | Back to back assurance to be taken by the supplier from OEM to supply spares for minimum 10 years and to be submitted. | Back to back assurance to be taken by the supplier from OEM to supply spares for minimum 10 years and to be submitted. |
| 73 | Penalty Clause: | Penalty Clause: |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 38 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 38 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender