Defence Statutory Bodies & Commissions/Committees Closing in 20 days TDR #56909686

Tender For Provn Of Lightning Protection System At Db Area, Signal Centre And Signal Complex And Wall Mounted Fans In Utilities Area And Augmentation To Lt Electrification From Sol To Nol Under Ge Chennai

Issued by Statutory Bodies & Commissions/Committees · Chennai, Tamil Nadu
Tender Value
46.15 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
20 days left
EMD
92500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Lightning Protection System At Db Area, Signal Centre And Signal Complex And Wall Mounted Fans In Utilities Area And Augmentation To Lt Electrification From Sol To Nol Under Ge Chennai

BOQ

Name of Work:- PROVN OF LIGHTNING PROTECTION SYSTEM AT DB AREA, SIGNAL CENTRE AND SIGNAL COMPLEX AND WALL MOUNTED FANS IN UTILITIES AREA AND AUGMENTATION TO LT ELECTRIFICATION FROM SOL TO NOL UNDER GE CHENNAI
Sl. No. Item Description
1Excavation in trenches not exc 1.5m in width and n.exc 1.5 M in depth and getting out excavated soil soft/loose soil. Complete all as specified and directed.
2Excavation in trenches additional 1.5m or part there of in depth beyond the first 1.5 m and not exe 3.0 m and getting out excavated soil soft/loose soil.Complete all as specified and directed.
3Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25cm Complete all as specified and directed.
4Removing excavated material / soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
5Material and Labour for Trenchless boring horizontally underneath the existing bituminous macadam road/drain crosswise by adopting trenchless tunneling work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including GI tubing 100 mm dia medium grade of any length with all fittings, socket welded and inserting it into the trenchless boring to carry LT UG machinery and other required materials in co-ordination with the concerned authorities etc., complete all as specified and as directed.
6DWC (Double wall corruguated) pipe 50x38 mm conforming to IS: 14930/ IS 16205 for protection of Electric cables including necessary snap-fit coupler required for fixing complete all as specified and directed.
7Supply & Lay in trenches fixed on wall (or) passing through pipes/in floors connecting up testing and commissioning of XLPE insulated armoured LT UG electric cable with aluminium conductor 1100V grade of size 120sqmm 3.5 core.(Location : Main I/C Cable for LT Panel) Complete all as specified and directed.
8All as per item 7.00 above but 35 sqmm 3.5 core
9All as per item 7.00 above but 16sqmm 4.0 core
10S & L trenches /fixed on walls by suitable clamps and jointing complete GI pipe light grade of 100 mm sizes Complete all as specified and directed.
11All as per item no. 10.00 above but for 50 mm dia
12Fabrication and installation of cable route indicator made out of 10 mm thick CI plate , oval shape of suitable size and embossed with Mark of \\" MES LT Cable \\" including 30 cm length angle iron support and embedded in PCC 1:3:6 and including excavation to requisite size and deep. Complete all as specified and directed.
13S&F LT Junction box made out of 3mm thick MS sheet and suitable MS angle frame of adaquate size, including TPN 415 Volts, 400 amps capacity Aluminium bus bar mounted on suitable insulators for tapping incoming/outgoing cable connection complete with front opening door with locking arrangment etc, all as specified and directed.Note : (a) Rate Quoted by the contractor inclusive of PCC Plinth for Junction box.(b) LT Danger Boards should be provided on both sides of Junction box.
14LT power distribution panel board out door type 415 volts50 Hz floor mounted front and back openable made out of 3mm thick MS sheet of suitable size to accommodate the following items vermin proof dust proof supported on and including ISMC 75 x 40 mm powder coated steel frame and totally powder coated with epoxy siemen grey colour from inside and outside with locking arragement and fixing arrangement i.e. nuts bolts washers,clamps ete with naturally air cooled bus bar 4 strip suitable for 400 Amps with detachable gland plate for incommingand outgoing cable including termination of cable ends both incoming and outgoing with sufficient working space inside including installing testing and commisioning complete all as specified and as directed.Note : (a) Rate Quoted by the contractor inclusive of PCC Plinth for LT Panel.(b) LT Danger Boards should be provided on both sides of LT Panel.IncomingFabrication of LT panel having thick 3 mm outdoor type including cutting welding jointing and brazing painting etc.RYB indication LED type 3 phase supply 3 NosS&F digital multi function meter complete - 01 NoNaturally air cooled bus bar 4 strip suitable for 400 Amps - 01 set. S&F MCCB 4 pole 36 KA 200 Amp complete - 01 No.OutgoingMCCB 4 pole 25 KA 63 Amp complete -05 NosMCCB 4 pole 25 KA 40 Amp complete - 01 No.Automatic timer switch( Havells ICELRPSL005) - 01 Set
15M & L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-22 ( 8.5 metres long)
16S& F for Cement concrete type B1 1:2:4 (20mm graded aggregate complete all as specified and directed.
17S& F for Cement concrete type C-2 1:3:6 (40mm graded aggregate complete all as specified and directed.
18S&F for 60 W new generation energy saving environmental friendly long life versalile pressure die cast aluminium IP-66 street light with high power LED as light source complete all as specified and as directed. Make Make Bajaj (Cat No. NEXO 72L WH PO PC SD) or equivalent for Havells /Philips /Crompton
19S/F in repairs street light Junction box of size for steel with operation suitable for accommodating and including heavy duty PVC connector block 30 amp three phase with one number single pole MCB 06 Amps complete including fixing to pole with suitable brackets, bolts/nuts in connecting cable in testing Complete all as specified and directed.
20Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal groungnd level) with top edgee of the plate not less than 1.5m below normal GL connected to GI earth strip of size 32x6 mm by means of bolts, nuts, check nuts washers of GI or steel all as shown in electrical plate No-5 of SSR Part I connected to machanery/equipments installed power house/sub station all as specified including testing on completion.Note No-1 the unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble( Notes) Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004.
21Earthing complete with Copper earth plate electrode of size 60cm x 60cm x 3.15 mm thick burried directly in ground( earth pit not less than 2.25 m deep below the normal groungnd level) with top edgee of the plate not less than 1.5m below normal GL connected to Copper earth strip of size 20x3 mm by means of bolts, nuts, check nuts washers of copper all as shown in electrical plate No-5 of SSR Part I connected to machanery/equipments installed power house/sub station all as specified including testing on completion.Note (i) the unit rate shall also include for excavation earth work in any type of soil PCC (1:3:6) type C1 pit RCC 1:2:4 type B-1 cover reinforced with 8 mm dia CTD bars @ 150mm C/C both ways funnel with 15mm bore GI watering pipe 20mm dia bore GI protection pipe wire mesh and copper lugs complete in addition to item No 1(a) to (e) of preamble ( Notes) Under sub heading earthing specified on SI page NO-389 of SSR Part-II 2004.(ii) Marking the earth chamber with date of test, name of machine and earth value.
22M&L for point wiring of size 1.5 sqmm (two run) with PVC insulated unsheathed multistranded copper conductor cabel of 1100V grade drawn through new non metallic rigid PVC casing capping including accessories, casing caping in wall/floor and fixed on ceiling/roof etc, including pressed steel terminal boxes concealed in walls for housing modular switchs,sockets, fan regulators etc., incl provn of 1.5 sqmm PVC insulated copper earth conductor cable for earth continuity and connecting to common earth dolly complete for One 3 pin socket outlet 5 amps on independent board controlled by one switch.
23S& F for Modular Metal flush box 3 module complete all as specified and directed.
24S& F for modular cover plate with frame 3 module complete all as specified and directed.
25S&F modular sockets suitable for type AC 240V, 6 amps 2 module complete all as specified and directed.
26S&F modular switches suitable for type AC 240V, 6 amps 1 module complete all as specified and directed.
27Supply and fix Wall Mounted Fan of double String, steel body AC single Phase. 230V of size 400mm sweep with, blades, frame, louvers, Oscillation control knob, Tiliting control and white colour (Body and blades) complete all as specified and directed. Make : Bajaj Esteem Model No. 250552 or equivalent of Usha/Crompton.
28Supply and fix aluminium strip 25 x 3.00mm with saddles and fixing screws, insulators rawal plugs etc for conductor for roof and fixed on wall upto test point, including taking down of old corroded strips.
29Supply and fix galvanized iron strip 32 x 6mm fixed with saddles & fixing screws, PVC dash fastners, insulators fixed from test point to earth on walls or burried in ground / drawn into hume pipe, including taking down of old corroded strips, complete all as specified and directed.
30Supply and fix single pointed air termination Aluminium rod 12mm dia, 300 mm long, including taking down of old termination rod, complete all as specified and directed.
31Test point terminal block made of gun metal or phosphorous bronge 75 x 75 x 25mm of 6mm thickness drilled and screwed including 3 Nos 8mm dia 25mm long hexagonal head brass screws including box of size 90 x 90 x 90mm made of 1.6mm plain sheet and screwed to wall for protection of test point, including taking down of old corroded box, complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56909686
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46.15 Lakhs
LAST DATE 29-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Lightning Protection System At Db Area, Signal Centre And Signal Complex And Wall Mounted Fans In Utilities Area And Augmentation To Lt Electrification From Sol To Nol Under Ge Chennai
Basic Detail
Tender No 8988/E8
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 08 Aug 2026
Submission Date 29 Aug 2026
Open Date 31 Aug 2026
Finance
Tender Value 46.15 Lakhs
Tender Fee 500
EMD 92500
Exemption Available
Document List
15410148-6565-4e40-b53f-97b55794695b.html
BOQ_877764.xls
Tender8988.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 20 days
Aug 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

15410148-6565-4e40-b53f-97b55794695b.html

xls

BOQ_877764.xls

pdf

Tender8988.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail