Tender For Maintenance Of Street Lights, Security Lights And Connected Works At Cijws Vairengte
Tender Value
38 Lakhs
Estimated cost
Bid Submission
29 Aug 2026
4 days left
EMD
76000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolasib → Mizoram
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Maintenance Of Street Lights, Security Lights And Connected Works At Cijws Vairengte
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 19-Aug-2026 | Revised BOQ | BOQ | 29-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | E & M Division Items |
| 2 | Dismantling steel pole/struts any size for reuse within the vairengte location including trasporting and stacking the site complete all as specified and directed. |
| 3 | Demoletion of PCC work as coping/base foundation of PCC/steel tubular pole all as directed. |
| 4 | Excavation in trenches n. exc 1.5 mtr in depth and not exc. 1.5 mtr in wide and getting out in soft/loose soil for laying of cables all complete all as specified and directed. |
| 5 | Returning filling in including spreading levelling watering and well ramming in layres not exceeding 25 cm thick in hard/ dense soil. |
| 6 | Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5m above the starting point. |
| 7 | Material and labour for sand cushioning for under ground cable with river sand for protection of cable including spreading and consolidations, complete all complete all as specified and directed. |
| 8 | M & L for laying of bricks locally available sub class 'B' bricks (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all complete all as specified and directed by Engr-in-Charge |
| 9 | M&L PCC (1:4:8) type D-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for pole and stay complete all complete all as specified and directed. |
| 10 | M&L PCC (1:3:6) type C-1 using 20mm graded aggregate as in coping of pole etc including form work complete all complete all as specified and directed. |
| 11 | M&L for checking/testing of street lights fittings any type, to detect the fault and repair on pole (if minor fault like remove carbon,lose connection etc) all as directed. |
| 12 | Supply and Fixing old steel tubular swaged poles type 410 SP-31 (9.0 metres long) fixing with concrete complete with cast iron base plate, finial taper plug, bolts, nuts and screws complete all as specified complete all as specified and directed.Note: Execavation of foundation, earth work, PCC work shall be measured and paid seperatly. |
| 13 | Supply and Fixing steel tubular swaged poles type 410 SP-31 (9.0 metres long) complete with cast iron base plate, finial taper plug, bolts, nuts and screws complete all as specified complete all as specified and directed.Note: Execavation of foundation, earth work, PCC work shall be measured and paid seperatly. |
| 14 | Strip opening and taking down carefully defective/non functional street light fittings of LED's from its existing position and capacity & refixing the same after checking of serviceability (the power supply can not be meet to driver/ flexible cable burnt from junction box to driver/ control MCB not working in junction box) of the fitting if the fitting can not be repaired/functionable, the old U/s fitting to be deposite to MES store for reapair and re-assembling and testing complete all complete all as specified and as directed by Engr-in-Charge.Note :- (a) Any other items i.e MCB, flexible cable to be measured and paid separately.(b) Contractor provide Extendable wheel laddar also including above job |
| 15 | S&F LED street light fitting 90 watt 230V AC outdoor type with high pressure die cast aluminumhosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistan including thermal management in multiple optics complete with IP-65/66 protection ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories incl taking down old existing old light fitting complete all as specified and directed. |
| 16 | S&F LED street light fitting 60 watt 230V AC outdoor type with high pressure die cast aluminumhosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistan including thermal management in multiple optics complete with IP-65/66 protection ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories incl taking down old existing old light fitting complete all as specified and directed. |
| 17 | S&F LED street light fitting 100 watt 230V AC outdoor type with high pressure die cast aluminumhosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistan including thermal management in multiple optics complete with IP-65/66 protection ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories incl taking down old existing old light fitting complete all as specified and directed. |
| 18 | S&F LED street light fitting 35 watt 230V AC outdoor type with high pressure die cast aluminumhosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistan including thermal management in multiple optics complete with IP-65/66 protection ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories incl taking down old existing old light fitting complete all as specified and directed. |
| 19 | Striping out and taking down carefully defective/non functional gate/garden light/post top lantern fittings of LED's from its existing position and capacity & refixing the same after checking of serviceability (the power supply can not be meet to driver/ flexible cable burnt from control panel to driver) of the fitting if the fitting can not be repaired/functionable, the old fitting to be replaced by new fitting as per given in this sch as per directed by Engr-in-Charge.Note :- (a)other items i.e flexible cable to be measured and paid separately. |
| 20 | S&F Post top lantern LED type 20 watts 230V AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and lamp complete ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories incl taking down existing old light fitting complete all as specified and directed. |
| 21 | S&F Post top lantern LED type 45 watts 230V AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and lamp complete ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories incl taking down existing old light fitting complete all as specified and directed. |
| 22 | S & F LED Step light 6 Watt outdoor type 230 V IP-65 dust light and protected form heavy range complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and all acessories incl taking down existing old light fitting complete all as specified and directed. |
| 23 | Taking down old existing light fittingand S & F LED bollard light 10Watt tripod type with soft 360 degrree light distribution type 230 V complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and all acessories incl taking down existing old light fitting complete all as specified and directed. |
| 24 | Striping out and taking down carefully defective/non functional flood light/bldg security light for > 10m high bldgs of LED's from its existing position and capacity & refixing the same after checking of serviceability (the power supply can not be meet to driver/ flexible cable burnt from control panel/distribution box to driver/ control MCB not working in distribution box) of the fitting if the fitting can not be repaired/functionable, the old fitting to be replaced by new fitting and re-assembling and testing incl taking down existing old light fitting complete all as specified and directed.Note :- (a) Any other items i.e MCB, flexible cable to be measured and paid separately. |
| 25 | Taking down old and S&F LED Flood light 70 watt 230V AC outdoor type with high pressure die cast aluminumhosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistan including thermal management in multiple optics complete with IP-65/66 protection ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories complete all as directed at site complete.Make:-Philips |
| 26 | Taking down old and S&F LED Flood light 120 watt 230V AC outdoor type with high pressure die cast aluminumhosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistan including thermal management in multiple optics complete with IP-65/66 protection ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories complete all as directed at site complete. |
| 27 | S&F LED Flood light 210 watt 230V AC outdoor type with high pressure die cast aluminumhosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistan including thermal management in multiple optics complete with IP-65/66 protection ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and all acessories incl taking down existing old light fitting complete all as specified and directed..Note:- fixing on Highmast height 12mtr arragement by contrctor down pully and fixed on it again upward same existing postion |
| 28 | S & F of MCB SP 6-32 Amps 230V 10KA 'C' curve complete incl taking down old existing unserviceable one complete all as specified and directed by Engr-in-Charge. |
| 29 | S & F of PVC insulated unsheathed flexible copper conductor flexible cable three core multi stranded 2.5 Sqmm and incl taking down existing old one complete all as specified and directed |
| 30 | S & F thermoplastic cable junction box IP 65 with plain walls of size 325x220x150mm and making suitable size hole for cable entry complete with cable terminals/connectors and other fittings fixed on poles with MS flat iron nut bolts, washers and double compressor metal glands of suitable sizes etc and disconnecting of existing junction box incl taking down existing old light fitting complete all as specified and directed. |
| 31 | M&L painting of LT/HT steel tubular pole any type of size externaly above foundation and junction box including all MS work with one coat of aluminium paint after scraping /cleaning well the existing surface complete all complete all as specified and directed by EIC. Note :- The item included in the painting 3 Nos 30 cm wide bands black & Yellow synthetic enamel paint in alternate layer upto 1.0 mtr high above foundation and writing the pole No in 5 cm wide on base of yellow colour with HT/LT as per direction of Engr-in-Charge. Please Enable Macros to View BoQ information |
| 32 | M&L painting of LT/HT steel tubular pole any type of size externaly above foundation and junction box including all MS work with one coat of aluminium paint after scraping /cleaning well the existing surface complete all complete all as specified and directed by EIC. Note :- The item included in the painting 3 Nos 30 cm wide bands black & Yellow synthetic enamel paint in alternate layer upto 1.0 mtr high above foundation and writing the pole No in 5 cm wide on base of yellow colour with HT/LT as per direction of Engr-in-Charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 19, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Aug 29, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysAug 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender