Tender For special Repairs To 36 X Bathrooms And Toilets Blocks With Water Proofing Of Bldg No. P-57, P-58, P-59, P-61, P-62 & P-63 At No. 2Mt Bn, annual maintenance contract C & C Under Ge (East) Lucknow.
Tender Value
1.47 Crore
Estimated cost
Bid Submission
05 Sep 2026
13 days left
EMD
2.22 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Lucknow → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repairs To 36 X Bathrooms And Toilets Blocks With Water Proofing Of Bldg No. P-57, P-58, P-59, P-61, P-62 & P-63 At No. 2Mt Bn, annual maintenance contract C & C Under Ge (East) Lucknow.
BOQ
| Sl. No. | Item Description |
| 1 | M&L for brick work with fly ash bricks, old size, straight or curved on plan exceeding 6 mtr mean radius and built in cement mortar 1:6 complete all as specified and directed. |
| 2 | All as per item No-01 above but except bricks ( bricks recovered from demolition to be used) |
| 3 | Demolition brick work/stone boulder masonry, built in cement mortar incl all quions, arches,pillars etc complte all as specified |
| 4 | M & L for brick work with red bricks straight or curved on plan to any radius in half brick thick walls built in CM 1:4 to any radius complete all as specified and directed. |
| 5 | Complete removal of existing treatment on wall/ roof projections including facia, cornices etc by scrapping with mechanical sander (having mechanical vaccum mechanism) with sanding pad of appropriate grit to make surface clean,free from dust, loose paint etc by skilled labour complete all as specified and directed. |
| 6 | Material & Labour for preparation of old plastered/new surfaces of walls and applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and directed. |
| 7 | Complete removal of existing treatment or preparation of newly plastered surface of wall applying two coats of oil bond distemper over a coat of primer over a coat of wall care putty 1 mm thick to make surface even and smooth, and complete all as specified and directed. |
| 8 | M & L for applying minimum 1mm thick wall care water proofing putty over prepared surface to achieve the surface even and smooth for painting complete all as specified and directed. |
| 9 | M&L for new plastered on ceiling surface and applying three coat of white wash complete all as specified and directed. |
| 10 | M & L for complete removal of existing treatment on ceiling surface and preparation of old plastered ceiling surface and applying two coats of white wash complete all as specified and directed. |
| 11 | M&L for rendering/plaster by using readymix mixture of thickness 12 mm to 15 mm on newly prepared surface and plastering the wall surface with white cement based polymer modified self curing mortar, all complete as per the direction of Engineer-in-Charge. |
| 12 | Repair to plaster by using readymix mixture of thickness 12 mm to 15 mm and taking down cement or cement lime plaster, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-in-Charge. |
| 13 | Repair to plaster by using readymix mixture of thickness 5 mm to 7 mm in ceiling including taking down cement or cement lime plaster, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-in-Charge. |
| 14 | Demolition of sunken slab floor or WC and Bath including WC trap etc incl taking down loose filling of aggregate in any type and removing where direted and providing water proofing treatment of sunken slab in following . (a) 15mm thick rendering on vertical sides of RCC slab in CM 1:3 mixed with WP chemical Cement + of Nerolac Perma/STP/Asian Confirm to IS 2645 - 9103 as per manufacturer instructions. (b) Cleaning the concrete surface by brushing and watering and remove all surface inperfections. (c) Fixing 40mm dia PVC Pipe 450mm long bottom of the sunken and wraping of bath seal tape on the pipes inserted through walls to floor are and seal it (Perma Butyl tape product of Nerolac Perma/ STP/Asian and grouting around the inserted pipes by porable grout as directed by Engr-in-Charge.(d) Make angle fillets by mixing sand cement and Nerolac Perma Hypercrete/STP/Asian on all corners.(e) Brushing two coats with high performance cementitious elastomeric two components water proofing coating of Nerolac Perma Super 2K/STP/Asian of thickness 1mm in two coats, Above treatment shall be giving upto height 15cm from bottom slab and allow it dry completely. Above material shall be confirm to below properties- 1. Bulk Density - 1.73g/cc, 2. Elongation - 100% as per ASTM D412 (Min) 3.Hydrostatic Pressure - 4bars as per ASTM D 7088, 4. Adhesion to concrete- Greater than 1.5N/mm2, 5. Crack Bridging ability as per AS/NZS 4548.5 Min 1mm. 6. DFT - 1mm in two coats. Seperation Layer- Providing & Laying 120 gsm non woven geo textile membrane over waterproofing coating to protect the coating prior the screed.(f) Providing PCC 1:2:4 type B-1 using 20mm graded stone aggregate mixed with intergral waterproofing compound Cement + of Nerolac Perma as per manufacturer instructions in sunken slab for making slope to wrap hole.(g) Fill the sanitary gaps with Nerolac PermaSIKA/Asian sealing compounds complete. |
| 15 | Providing PCC 1:7:12 type F-2 using 40mm graded stone aggregate in sunken slab . |
| 16 | Dismantling brick tiles or terracing tiles, single layer of roofs and old APP removal including mud pushaka etc roughening surfaces of old concrete by picking, sweeping/Brushing clean and washing down with water to remove dust and apply neat cement slurry with 3.0kg of cement per sq. metre complete all as directed. |
| 17 | M&L PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in roof kerbs/padding /benching or mud stops, and platform for mounting service tanks, rounded,chamfered on edges including necessary use and waste of from work etc all as specified and directed. |
| 18 | M&L for screed bed 10mm thick in CM 1:3 on concrete surfaces/ roof/ parapet wall using WPC as per manufacturer instruction finished fair & even without using extra cement complete all as specified and directed. |
| 19 | M&L for providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. Please Enable Macros to View BoQ information |
| 20 | M&L for providing, cement concrete Type B1 1:2:4 (20 mm graded aggregate) in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 08, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysSep 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender