Educational and Research Institute Boards / Undertakings / PSU Closing in 8 days TDR #56907763

Tender For Supply, Fixing, Testing And Commissioning Of Wall Mount Split Acs In Automation Section At Examination Block, Main C Us University Of Kashmir (Advertised Cost Rs. 4.32 Lac)

Issued by Boards / Undertakings / PSU · Srinagar, Jammu and Kashmir
Tender Value
4.32 Lakhs
Estimated cost
Bid Submission
17 Aug 2026
8 days left
EMD
8640
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Srinagar → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Supply, Fixing, Testing And Commissioning Of Wall Mount Split Acs In Automation Section At Examination Block, Main C Us University Of Kashmir (Advertised Cost Rs. 4.32 Lac) , Supply, Fixing,Testing And Commissioning Of 2Tr Wall Mount Split Ac Hot & Cold, Cop Cooling 3.04, Cop Heating 3.54, Maximam Power 2.220Kw, Current Cooling/ Heating Not More Than 9.06A Maximam Operating Pressure Hi 42.9/Lo22.6 Bar (3 And Above Star Ratting) Wall Mounted Split Fully Inverter Type Ac With Heat Pump, Fan Coil Unit And Condensing Unit Hot And Cold Operation Temperature Range Should Be Minimum -10(Minus) To 46 Degree C Inverter Technology . Including Control Wiring, Ac Remote With Cells, Refrigerant Gas Filling Comlete In All Respects. (Mitsubishi, O General, Toshiba Or Equivalent) , Supply Installation Testing and Commissioning of 2X Copper Piping (Soft ) With 9Mm Nitrite Rubber Insulation On Both Pipes With Steel Clamps And Including Fully Gi Clamps & Tapping , Supplying And Fixing Of Medium Class Pvc Pipe Of Requied Size Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supply Installation Testing and Commissioning of Control And Power Cable For Connection Of Indoor And Outdoor Units As Per Specifications Of Oem , Supply And Fixing Of M.S Stands For Outdoor Units As Per Specifications Of Oem , Supply Of 5Kva Automatic Voltage Regulator (Avr) Air Cooled Wall Mounted Having Input Line Voltage From 90 Volts To 260 Volts With Tme Hi, Low Cut And Time Delay Protections. Including Required Length Of Recommended Leads Of Reputed Make , Providing And Fixing Of Ac Points Using 4 Sq.Mmpvc Insulated Copper Wire Of Frls Through 1 2Mm Heavy Duty Pvc Conduit And Providing And Fixing Of 32 Amp. Of Modular Mcb, Socket Recessed In Wall Covered With Modular Sheet/ Ms Box Of Required Size Including Providing And Fixing Of 4Mm² Pvc Insulated Copper Wire As Earth Wire, Point Taken Up To D.B. Duly Tested And Commissioned, Complete Point In All Respetsnote: All Items Included Like Conduit/ Channel, Wire, Pvc/Ms Box, Switches Etc. , Providing And Fixing Of Ac Points Using 4 Sq.Mmpvc Insulated Copper Wire Of Frls Through 1 2Mm Heavy Duty Pvc Conduit And Providing And Fixing Of 32 Amp. Of Modular Mcb, Socket Recessed In Wall Covered With Modular Sheet/ Ms Box Of Required Size Including Providing And Fixing Of 4Mm² Pvc Insulated Copper Wire As Earth Wire, Point Taken Up To D.B. Duly Tested And Commissioned, Complete Point In All Respetsnote: All Items Included Like Conduit/ Channel, Wire, Pvc/Ms Box, Switches Etc.

BOQ

Name of Work:- Supply, fixing, testing and commissioning of wall mount Split ACs in Automation Section at Examination Block, Main C us University of Kashmir (Advertised cost Rs. 4.32 Lac)
Sl. No. Item Description
1Supply, fixing,testing and commissioning of 2TR wall mount Split AC Hot & Cold, COP cooling 3.04, COP heating 3.54, Maximam power 2.220KW, Current cooling/ heating not more than 9.06A Maximam Operating pressure Hi 42.9/Lo22.6 bar (3 and above star Ratting) wall mounted split fully inverter type AC with Heat Pump, fan coil unit and condensing unit Hot and Cold operation temperature range should be minimum -10(minus) to 46 degree C Inverter technology . including control wiring, AC remote with cells, Refrigerant Gas filling comlete in all respects. (Mitsubishi, O General, Toshiba or equivalent)
2SITC of 2x copper piping (soft ) with 9mm nitrite rubber insulation on both pipes with steel clamps and including fully GI clamps & Tapping
3Supplying and fixing of medium class PVC pipe of requied size along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
4SITC of control and power cable for connection of indoor and outdoor units as per specifications of OEM
5Supply and fixing of M.S Stands for outdoor units as per specifications of OEM
6Supply of 5KVA Automatic Voltage Regulator (AVR) Air cooled wall mounted having input line voltage from 90 volts to 260 volts with tme hi, low cut and time delay protections. Including required length of recommended leads of reputed make
7Providing and fixing of AC points using 4 sq.mmPVC insulated copper wire of FRLS through 1” 2mm heavy duty PVC conduit and providing and fixing of 32 Amp. of Modular MCB, socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all respetsnote: all items included like Conduit/ CHANNEL, wire, PVC/MS box, switches etc. Please Enable Macros to View BoQ information
8Providing and fixing of AC points using 4 sq.mmPVC insulated copper wire of FRLS through 1” 2mm heavy duty PVC conduit and providing and fixing of 32 Amp. of Modular MCB, socket recessed in wall covered with modular sheet/ MS box of required size including providing and fixing of 4mm² PVC insulated copper wire as earth wire, point taken up to D.B. duly tested and commissioned, complete point in all respetsnote: all items included like Conduit/ CHANNEL, wire, PVC/MS box, switches etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56907763
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 4.32 Lakhs
LAST DATE 17-08-2026
Authority
Authority Name University Of Kashmir (Jammu)
Work Description Tender for Supply, Fixing, Testing And Commissioning Of Wall Mount Split Acs In Automation Section At Examination Block, Main C Us University Of Kashmir (Advertised Cost Rs. 4.32 Lac) , Supply, Fixing,Testing And Commissioning Of 2Tr Wall Mount Split Ac Hot & Cold, Cop Cooling 3.04, Cop Heating 3.54, Maximam Power 2.220Kw, Current Cooling/ Heating Not More Than 9.06A Maximam Operating Pressure Hi 42.9/Lo22.6 Bar (3 And Above Star Ratting) Wall Mounted Split Fully Inverter Type Ac With Heat Pump, Fan Coil Unit And Condensing Unit Hot And Cold Operation Temperature Range Should Be Minimum -10(Minus) To 46 Degree C Inverter Technology . Including Control Wiring, Ac Remote With Cells, Refrigerant Gas Filling Comlete In All Respects. (Mitsubishi, O General, Toshiba Or Equivalent) , Supply Installation Testing and Commissioning of 2X Copper Piping (Soft ) With 9Mm Nitrite Rubber Insulation On Both Pipes With Steel Clamps And Including Fully Gi Clamps & Tapping , Supplying And Fixing Of Medium Class Pvc Pipe Of Requied Size Along With Accessories In Surface/Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. , Supply Installation Testing and Commissioning of Control And Power Cable For Connection Of Indoor And Outdoor Units As Per Specifications Of Oem , Supply And Fixing Of M.S Stands For Outdoor Units As Per Specifications Of Oem , Supply Of 5Kva Automatic Voltage Regulator (Avr) Air Cooled Wall Mounted Having Input Line Voltage From 90 Volts To 260 Volts With Tme Hi, Low Cut And Time Delay Protections. Including Required Length Of Recommended Leads Of Reputed Make , Providing And Fixing Of Ac Points Using 4 Sq.Mmpvc Insulated Copper Wire Of Frls Through 1 2Mm Heavy Duty Pvc Conduit And Providing And Fixing Of 32 Amp. Of Modular Mcb, Socket Recessed In Wall Covered With Modular Sheet/ Ms Box Of Required Size Including Providing And Fixing Of 4Mm² Pvc Insulated Copper Wire As Earth Wire, Point Taken Up To D.B. Duly Tested And Commissioned, Complete Point In All Respetsnote: All Items Included Like Conduit/ Channel, Wire, Pvc/Ms Box, Switches Etc. , Providing And Fixing Of Ac Points Using 4 Sq.Mmpvc Insulated Copper Wire Of Frls Through 1 2Mm Heavy Duty Pvc Conduit And Providing And Fixing Of 32 Amp. Of Modular Mcb, Socket Recessed In Wall Covered With Modular Sheet/ Ms Box Of Required Size Including Providing And Fixing Of 4Mm² Pvc Insulated Copper Wire As Earth Wire, Point Taken Up To D.B. Duly Tested And Commissioned, Complete Point In All Respetsnote: All Items Included Like Conduit/ Channel, Wire, Pvc/Ms Box, Switches Etc.
Basic Detail
Tender No F(E.Tend)(S/F/T/C AC Auto. Sec.)(UCD)/KU/13/26
Bidding Type Tender
Location
City Srinagar
State Jammu and Kashmir
Key Dates
Publish Date 08 Aug 2026
Submission Date 17 Aug 2026
Open Date 18 Aug 2026
Finance
Tender Value 4.32 Lakhs
Tender Fee 200
EMD 8640
Exemption Not Available
Document List
Tendernotice_1 (11).pdf
932dc0ad-cb09-47a1-b001-c36e55f926b7.html
BOQ_1058776.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 08, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 17, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 8 days
Aug 18, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1 (11).pdf

html

932dc0ad-cb09-47a1-b001-c36e55f926b7.html

xls

BOQ_1058776.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders