Tender for Construction Of Living Accn For Coy And Pl Alongwith Allied Infra At Rajouri Under Ge 862 Ews
BOQ
| Sl. No. | Item Description |
| 1 | Sch 'A' Part-I (Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 2 | Construction of building block of living accn for TA COY and DSC PL alongwith allied infra in AP-252 at Rajouri complete all as shown on drawings and as specified. |
| 3 | Total Amount of Sch 'A' Part - II (Site Clearance and Development Work) |
| 4 | Total Amount of Sch 'A' Part - III (Sec-I) (Internal Water Supply Work) |
| 5 | Total Amount of Sch 'A' Part - IV (Sec-I) (Internal Electric Supply Work) |
| 6 | Total Amount of Sch 'A' Part - V (Plumbing Work) |
| 7 | Total Amount of Sch 'A' Part - VI (Area Drainage Work) |
| 8 | Total Amount of Sch 'A' Part - VII (Protective Work) |
| 9 | Total Amount of Sch 'A' Part - VIII (Sec-I) (Sewage Disposal Work) |
| 10 | Total Amount of Sch 'A' Part - IX (Road, Path and Culver Work) |
| 11 | Total Amount of Sch 'A' Part -X (Sec-I) (External Water Supply Work) |
| 12 | Total Amount of Sch 'A' Part -XI (Sec-I) (External Electric Supply Work) |
| 13 | Total Amount of Sch 'A' Part -XII (Sec-I) (Rain Water Harvesting Work) |
| 14 | Sch 'A' Part-III (Sec-II) (Internal Water Supply Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 15 | 600mm x 900mm bevelled edge mirrior of selected quality glass mounted on 6mm AC building board of commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 16 | Sch 'A' Part-IV (Sec-II) (Internal Electric Supply Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 17 | Point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20mm dia medium grade (MMS) and all accessories are concealed in walls / roofs / floors / ceiling etc; including modular metal flush box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick including modular top cover plate as per numbers of switch modules for fixing of modular switches, sockets, fan regulators, red colour indicator, blank plates etc. as approved colours and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- Note No1: All necessary accessories such as modular steel box, top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used of same make/brand only. Note No 2: Any cutting /leaving /forming holes, chases etc., in walls, floors and ceiling as required and making good the same, shall be deemded to be included in lump sum Sch 'A' Part-I as per para 10(b) in Sch 'A' BOQ Notes. |
| 18 | All as per Srl item No. 14.00 here-in-before above but one light point controlled by two way switch. |
| 19 | All as per Srl item No. 14.00 here-in-before above but for socket out 5 amps on same board. |
| 20 | All as per Srl item No. 14.00 here-in-before above but for socket outlet 5 amps on independent board. |
| 21 | All as per Srl item No. 14.00 here-in-before above but for one 3 pin 15 amps socket outlet on independent board with 2.5 sqmm PVC insulated FRLSH multistranded copper cable with 2.5 single core multistranded FRLSH copper cable as earthing lead. |
| 22 | LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED tube light including connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed. |
| 23 | LED Tube light fitting, 1x 20 watts, decorative ultra slim linear LED lighting fixture with co. extruded polycarbonate body, environmental friendly, energy efficient ready to use pack complete rewired, premium 20W LED batten, connecting electrically to ceiling rose to fitting using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 sqmm, 3 core, including removing old/unserviceable, complete all as required at site or directed. |
| 24 | LED street light fitting 35 Watt, 230 V, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket made to shape with GI pipe of 40mm dia, 1.5m length, made to shape and fixed on wall with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, complete all as specified and directed. |
| 25 | Concealed sub main wiring of two run with 06 sqmm single core PVC insulated, FRLSH, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit 25mm dia, medium grade, ISI marked and fixed, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLSH, multi stranded copper conductor cable as earth continuity conductor in green colour, connected to common earth dolly, complete all as specified and as directed. Note No 1: Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only.Note No 2: Any cutting /leaving /forming holes, chases etc., in walls, floors and ceiling as required and making good the same, shall be deemded to be included in lump sum Sch 'A' Part-I as per para 10(b) in Sch 'A' BOQ Notes. |
| 26 | Ceiling fan complete with blades, down rods, alongwith steel wire rod for additional safety modular fan step regulator, 120W, 2 module and accessories, 230V, 1200mm sweep, min air delivery 210CFM, with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC), complete all as specified and directed. |
| 27 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of earth plate not less than 1.5m below normal ground level connected with galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel complete, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15 type B1 in pit with angle iron (25x25x3)mm frame work with precast RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways and 12mm dia MS fabricated handle, test point etc. in and including light grade GI protection pipe 15mm bore up to 7.5m length for drawing in earth lead wire, all as shown in electric plate No. 3 of SSR Part-I complete with necessary earth work in any type of soil, removal of soil to a distance not exc. 50m, testing on completion complete all as specified and directed.Note:-(i) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.(ii) Supply and fix of the earth Pit chamber board for all earthing fixe in this project of 3.15mm thick mild steel sheet of size min 45cm x 30cm fixed with 12mm thick MS rod two Nos up to 90cm height by nut/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters min 6cm height i.e; earth Pit No. location, earthinc test value and date and other letters complete all as specified and directed by Engr- in-Charge. |
| 28 | Sch 'A' Part - VIII (Sec-II) (Sewage Disposal) Note: This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 29 | Construction of septic tank for 50 users (Brick construction) complete all as shown on drg No. CEUZ /TD-1585/2021 sheet 1/4 to 4/4 and as specified. |
| 30 | Construction of soakage well (Brick construction) 3.6m dia and 4.5m deep below inlet pipe level (depth from inlet pipe to ground level 45cm), complete all as specified and shown on drg No. CEUZ/TD-1585/2021 sheet 1/4 to 4/4. |
| 31 | Sch 'A' Part - X (Sec-II) (External Water Supply) Note: This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 32 | Construction of Valve pit of size (60x60x60)mm (Internal dimensions) using PCC (1:4:8) type D-2, using 40mm graded crushed stone aggregate for foundation, 10cm thick and 100mm off sets on all sides, 230mm thick brick masonary walls built in cement mortar (1:6), 15mm thick rendering all around the masonry work in cement (1:6), for internal and up to 15cm below GL for external surfaces of walls, 50mm thick PCC (1:2:4) type B-1 using with 20mm graded crushed stone aggregate including necessary form work for grouting including 3.15mm thick, MS top sheet cover double door with locking arrangement welded to MS frame made out of (50x60x6)mm angle iron frame fixed with hold fasts including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation in any kind of soil, returning filling in and removal of surplus soil to a distance not exceeding 50m complete all as specified and shown on drawing. |
| 33 | Sch 'A' Part - XI (Sec-II) (External Electric Supply) Note: This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 34 | Double walled corrugated (DWC HDPE) pipe of size 75mm including snap fit coupler conforming to IS16205 (Pt-II)/IS 61386 Pt-II for protection of under ground cable complete all as specified and directed. |
| 35 | Supply, installation, commissioning and testing LT weather proof panel board, factory made, dust and vermi proof, powder coated, outdoor type, IP 65, double door shutter, made out of CRCA 3.15mm thick outer and 1.6mm thick for inner door with angle iron (50x50x6)mm outoor, floor mounting type with Aluminium bus bar suitable for 3 phase, 4 wire 50 Hz, AC supply including PCC work, 0.6 mtr above ground level grouting etc; complete all as specified and directed as per following provisions:-INCOMMING :-(a) MCCB 4 pole, 415V, Adjustable type, 100 amps with breaking capacity 25 KA, Load line type - 01 No(b) Ammeter Digital type (0-150A) - 01 No(c) Voltmeter Digital type (0-500V) - 01 No(d) CT's - 03 No(e) Indicating lamp LED type - 03 NosOUTGOING :-(a) MCCB 4 pole, 415V, Adjustable type, 63 amps with breaking capacity 20 KA, Load line type - 01 No (b) 32 Amp, SPN MCB of 10 KA Rupturing capacity \\"C\\" Series - 01 No |
| 36 | FRP looping box of size 200mmx140mmx95mm with connector and comprising of MCB, SP 6 Amps, ISI marked, 240V complete with and including providing GI clamps, nuts, bolts etc; suitable for fixing on PCC pole/ wall/steel tubular pole etc; complete all as specified and directed. |
| 37 | Street light bracket made out of 40mm dia, medium grade GI pipe of 1.2m length, both end hole for fixing street light/security light fitting on steel tubular pole including MS clamps, back plates fabricated from structural steel section 25mmx4mm, including nuts, bolts, washers, welding cold or hot, drilling of holes for bolts, in any shape or size including two coats of aluminium paint over a coat of red oxide primer after preperation of steel surfaces, complete all as specified and directed. |
| 38 | Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6.0mm thick buried directly in ground ( earth pit not less than 2.25 mtr below normal ground level) with top edge plate not less than 1.5 metre below normal ground level connected to galvanized earth strip of size (32x6)mm as earthing lead by means of bolts, nuts, chuck nuts and washers of galvanized iron earth lead with 15 cm thick alternate layers of charcoal dust & common slat including PCC pit in PCC 1:2:4 type B-1, RCC cover made out of cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with TMT steel bars 8 mm dia @150 mm c/c both ways with suitable handle and angle iron (40x40x5)mm frame, GI medium grade watering pipe 20mm bore and funnel with wire mesh, GI medium grade protection pipe 40mm bore up to main board complete as shown on electrical plate No 3 of MES Sch 2009 (Part-I) and testing on completion complete all as specified and directed. Note: (i) On testing after completion of earthing, if desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk & cost to the entire satisfaction.(ii) Supply and fix of the earth Pit chamber board for all earthing fixe in this project of 3.15mm thick mild steel sheet of size min 45cm x 30cm fixed with 12mm thick MS rod two Nos up to 90cm height by nut/bolts including spray painting with two coats of synthetic enamel black paint complete MS sheet both side including writing letters min 6cm height i.e; earth Pit No. location, earthinc test value and date and other letters complete all as specified and directed by Engr- in-Charge. |
| 39 | LED street light fitting 35 Watt, 230 V, AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket made to shape with GI pipe of 40mm dia, 1.5m length, made to shape and fixed on wall with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection, complete all as specified and directed. |
| 40 | Sch 'A' Part - XII (Sec-II) (Rain Water Harvesting Work) Note: This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 41 | Trail bore of 250mm dia upto 200 meter depth below ground level in any kind of soil including hard stone/boulder etc; complete all as specified and directed |
| 42 | Sch 'A' Part - XIII (Misc Items of work) Note: This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as \\"Rs. 0.00\\" under col.5 signifies this fact only. |
| 43 | Electric water heater, storage type steel body with glass line inner tank and heating element 2 KW capacity 25 litre, BEE 5 star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc; complete all as specified and as directed. |
| 44 | Earth work in excavation by mechanical means Hydraulic excavator)/ in foundation trenches or drains (exceeding 1.5 m in width or 10sqm on plan), including dressing of sides and ramming of bottoms, lift upto 3m, including getting out in all kind of soil (the excavated soil) and disposal of surplus excavated soil, within a lead of 50m complete all as specified and directed.Note:- Contractor may at his discretion use any means for excavation and width required at site. However payment shall be made for authorized width only as defined in preamble para 3.2.3 to section 3 of MES SSR Part-II. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 12, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysSep 14, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender