Tender For special Repair Of Roof Leakage Of It & S And Main Building Of Pcda(O) Pune Under Ge (South) Pune.
Tender Value
38.81 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
3 days left
EMD
77620
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Pune → Maharashtra
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repair Of Roof Leakage Of It & S And Main Building Of Pcda(O) Pune Under Ge (South) Pune.
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of cement concrete of any description in any position in sunken floor and roof slab padding & like etc including removal of debris outside MD land and dumping ground will be sorted out by contractor at their own arrangement complete all as specified and as directed. |
| 2 | Provide padding of PCC 1:2:4 type B-0 of uniform thickness of 50mm in two layers of 25mm thickness with chicken wire mess 0.91 mm dia, laid between two layers and of 12x12mm aperture.Top surfaces of PCC padding shall be finished even and smooth without using extra cement with false groove at 300x330 mm centre to centre, laid in slope.(Using water proofing compound of 3% by weight of cement or as per manufacturere instruction) including cleaning of surfaces by brushing and washing with water of any description (Note : Wpc shall be measured and paid seperately) |
| 3 | M & L for Water proofing treatment to RCC roof slab, walls, chhajjas etc, shall be carried out as per specified below including Removing of existing bituminous tarfelt including cement screed bed, PCC and clean the surface with wire brush and washing with water to achieve the original surface of slab before carrying out the PCC on Roof slab & Chajja all as spd and as directed.(a) M&L for applying One Coat of URP (Dr Fixit) liquid with cement solvent (mixer) on RCC Roof/Chajja before carry out the 10mm thick Cement plaster (1:4) on roof surface of slab and preparing the plastered surfaces of roof slab, walls, chajjas etc by brooming and free from dirt dust etc & evenly applying a coat of Shali Tex primer or its equivalent make as approved by GE, (solvent based bituminous primer) conforms to IS: 3384-1986, @ 0.30 Kg/Sqm shall be applied on the prepared and clean roof surface and parapet. Ensure not to apply when temperature is less than 5* C or during foggy period. Primer shall be allowed to dry for overnight. (b) Providing and laying APP (Atactic Polypropylene polymer) 3mm thick Super Thermolay Spun bonded non woven polyester reinforced APP modified water proofing membrane, black finished reinforced with non woven polyester matt weight not less than 3.5 Kg/Sqm. The laying of membrane with a 75 mm longitudinal and 100mm transverse direction overlap shall be provided and laid using LPG torch and sealing all joints etc |
| 4 | (c) Finally applying a coat of solar reflective bituminous aluminium paint @ 0.15 ltr/Sqm on the top of membrane surfaces complete all as specified & as directed by Engr in Charge. Note : i) Work should be done by OEM or its authorisd applicator who work should be able to furnish stagewise on site technical reports from concerned company technologist during currency of work and entire completion of work.ii) Contractor shall submitt 10 year OEM guaranttee for water proof treatment. |
| 5 | Supply only Integral waterproofing compound only(Make:- Pidilite CF 21 by Pidilite, DR.FIXIT, ShaliPlast LW+ by STP Ltd.)[Note : Contractor shall bring complete material incorporated in work with concern executive.] |
| 6 | M&L Cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry in ratio 1:3 all as specified and directed. |
| 7 | M&L for Removing building materials etc. to a distance of exc. 1000m and n.exc. 5000m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination ® (1 Load =2.5 Cum) |
| 8 | Removing of existing water tank of capacity 500,1000 or 2000 Ltr setting aside (or lowering if required) for repair, cleaning etc and reconnecting & refixing in same position after carrying out necessary roof treatment including necessary accesories required for fittings and GI Pipes if required complete all as specified and as directed.(NOTE : Necessary by pass arrangements for water supply is to be done by the contractor till completion of roof work.) |
| 9 | Supply and fixing of GI water tubing, medium grade with fittings, fixed to wall and ceiling (conceled) or laid in floor of size including taking up or down GI water tubing with fittings |
| 10 | (a) 15 mm bore |
| 11 | (b) 20 mm bore |
| 12 | (c) 25 mm bore |
| 13 | (c) 32 mm bore |
| 14 | S&F in repairs 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints including clamps fixed to wall, laid in trenches or in floors complete all as specified and as directed. |
| 15 | S & F in repairs 110mm dia, PVC (SWR) bends any radius complete all as specified and as directed . |
| 16 | S&F in repairs 110mm PVC (SWR) branch piece, single (single Y) equal or unequal complete all as specified and as directed. |
| 17 | S&F in repairs 110mm PVC (SWR) branch piece, double (double Y) equal or unequal with access door complete all as specified and as directed. |
| 18 | S&F in repairs 110mm PVC (SWR) junction Single (Single T) equal or unequal with access door complete all as specified and as directed. |
| 19 | M&L for rendering 10mm thick in cement plaster in cement mortar ( 1:4) with water proofing compounds finished even and smooth without using extra lime or cement including taking down cement or cement lime plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 20 | M&L for preparation of new surfaces of any description over 10cm width or girth, finishing walls with Acrylic smooth exterior paint of required shade. Two or More coat applied @ 1.67 ltr/10 sqm and including priming coat of exterior primer applied @ 2.20kg/10sqm complete all as specified and as directed. |
| 21 | M&L for raised pointing to random or polygonal rubble, uncoursed or brought up to course Cement Mortar 1:3 complete all as specified and as directed. |
| 22 | M&L for RCC Type B1, 1:2:4 (20mm graded stone aggregate) in chajjas. Incl demolition of Reinforced Cement Concrete (Reinforcement cut as required to facilitate demolition) of any description complete all as specified and as directed. |
| 23 | M&L for Mild Steel bars 10mm dia and over, cut to length, bent to shape required, icnluding cranking, bending spirally for hooping for cloumns, hooking ends and binding with and including steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 24 | M&L for Mild Steel bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for cloumns, hooking ends and binding with and including steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. |
| 25 | M & L for form work to sofits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed. |
| 26 | S& F in repair of rotational moulded polyethylene water storage tanks in replacement (vertical cylindrical with closed top) double layered ISI marked with existing inlet, outlet & provn of washouts (vent pipe all directed of following capacity (incl all new tank nipples of suitable size |
| 27 | (a) 1000 ltr |
| 28 | (b) 2000 ltr |
| 29 | S & F in repair ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule and fixed in position complete all as specified and directed. |
| 30 | (a) 20mm bore |
| 31 | (b) 25mm bore |
| 32 | S & F in repair of 20 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified. |
| 33 | S & F in repair of 25 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified. |
| 34 | S & F in repair of 32 mm Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified. |
| 35 | M&L for demolition of concrete surfaces and carry out the Roof Treatment and also apply the following process:- (i) open all crakes, clean, filling the crack joints with Pidilite Compound. (ii) Removing all dead skin and applying hard brushing for cleaning. (iii) apply pressure washing. (iv) U.R.P. & cement pesting.(v) leveling. (vi) Fiber mash pesting with U.R.P & Cement solvent . (vii) apply priming coating (viii) apply three coats on conc. surfaces as well as First Coat Processing thereafter drying the surface apply the second coat and again after drying the surface processing the Third coat on roof/chajja comp. The contractor has also submit the Ten year Guarantee for WPT. The treatment to be carried out on the concrete surfaces including cleaning all RCC surfaces as per manufacturer's specification/ datasheet and material should be utilised of approved make by GE comp all specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 3 daysSep 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 10 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender