Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56904654

Tender For Repair Maintenance Of Lt Fp Jbs Pole Box Apfc Panels Voltage Stabilizer High Mast Area Lighting Pump House Power House Store Of Em Installation At Danapur Under Ge Danapur Cantt

Issued by Statutory Bodies & Commissions/Committees · Patna, Bihar
Tender Value
43 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
15 days left
EMD
86000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Patna → Bihar
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair Maintenance Of Lt Fp Jbs Pole Box Apfc Panels Voltage Stabilizer High Mast Area Lighting Pump House Power House Store Of Em Installation At Danapur Under Ge Danapur Cantt

BOQ

Name of Work:-
Sl. No. Item Description
1M/L in replacement of cross arms, bracing, supports clamps and back plates fabricated from structural steel section incl nuts, bolts washers, welding, bending cold or hot drilling holes for bolts in any shapes or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including disconnecting/taking out old existing unsv cross arms complete all as specified and directed.
2Supply & Replace MCCB along with both side spreader link and nut bolts of appropriate size (Conforms to IEC:60947-II/IS:13947-II) in exisitng LT Panel box/Feeder Pillar boxes (KIOSK),in MCCB DBs of capacity 630 Amps, 4 Pole, 50KA, 415 Volt including disconnecting/taking out existing old unsv/burned MCCB, Ics= 100% of Icu* Adjustable overload settings: 0.8 - 1.0 x In, Fixed short-circuit settings: 10 x In, complete all as specified and directed.
3Same as item No 2 here in before but of capacity 200 Amps, 4 pole, 36 KA
4Same as item No 2 here in before but of capacity 160 Amps, 4 pole, 25KA
5Same as item No 2 here in before but of capacity 63 Amps, 4 pole, 16 KA
6S&F MCB, SP 10-32 Amps, 'C' Curve with breaking capacity 6KA, including disconnecting/taking out existing old unsv/burned Isolator complete all as specified and directed.
7Supply and fixing in replacement of automatic street light switch using infrared sensor based nature switch for automatic switching of street lights.Nature switch operation should be based on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off > 10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs.The sensor along with suitable power contactors incoming outgoing MCBS SP and and automanual (sensor bypass selection option should be enclosed in a pole /wall mountable enclosure made of rust proof electric shock proof termite proof and FR grade SMC Box conforming to IP54 single phase load of 8 KW with circuit wiring min 10 sq mm copper wire 40 Amps contactor ans suitable MCBs at both positions at incoming and out goings of breaking capacity 10 KA complete including necessary clamp (2 sets) / anchor bolt(4 nos) for fixing on pole / walll complete all as directed including taking down old one.
8S&F in replacement LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection complete, lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP66 protection and impact resistance of IK07 with 10 KV Built-in-Surge Protection Device, road way light fitting with high power LED as light source of capacity 90 watts with suitable drivers, > 120 Lm/W efficacy,Operating voltage:120–270V AC, 50Hz etc and connecting with 1.5 Sqmm copper conductor PVC insulated three core weather proof cable etc, fixing to wall/pole , complete all as specified and directed. Note : (i) Contractor has to produce LM-79/LM-80 certificate alongwith purchase vouchers.
9Same as item No 8 above but 60 watts.
10S&F in replacement LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrossion resistant complete with driver and lamp die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting, with high power LED as light source of capacity 100 watts with suitable drivers etc and connecting with 4.0 Sqmm aluminium conductor PVC insulated twin core weather proof cable,Operation Voltage-120–270V AC, 50Hz etc, fixing to wall/pole complete all as specified and directed. Note : (i) Contractor has to produce LM-79/LM-80 certificate alonwith purchase vouchers and Guarantee certificate from Manufacturer.
11Same as item No 10 above but 120 watts.
12Supply, fixing, in replacement connecting and testing post top light fitting in spherical shape polycarbonate PMMA clear diffuser and IP65 protection, new generation energy saving and environmental friendly long life aesthetically desinged aluminium decorative luminaires with high power LED as light source of capacity 1X40 watts, fixed to Pole/Wall in any position including taking down old existing street light fitting of any type and capacity complete all as specified and directed.
13Supply, fixing, in replacement connecting and testing post top light fitting in spherical shape polycarbonate PMMA clear diffuser and IP65 protection, new generation energy saving and environmental friendly long life aesthetically desinged aluminium decorative luminaires with high power LED as light source of capacity 1X25 watts, fixed to Pole/Wall in any position including taking down old existing street light fitting of any type and capacity complete all as specified and directed.
14Supply and lay in replacement in trenches/fixed to walls/poles etc connecting buy using lugs, testing and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with stranded aluminium conductor 4 Core 10 Sqmm complete all, as specified and directed Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
15Same as item No 14 above but 2 Core 10 Sqmm
16Same as item No 14 above but 4 Core 25 Sqmm
17Same as item No 14 above but 3.5 Core 70 Sqmm
18Same as item No 14 above but 3.5 Core 150 Sqmm
19Same as item No 14 above but 3.5 Core 240 Sqmm
20Taking out and Relaying of LT cable of size 10 sq mm to 50 Sqmm 2/3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed. Note: ( Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item)
21Taking out and Relaying of LT cable of size 70 sq mm to 150 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed. Note: ( Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item)
22Taking out and Relaying of LT cable of size 185 sq mm to 300 Sqmm 3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed. Note: ( Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item)
23Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth, for foundation of PCC/Steel pole, laying of cable in trenches etc and getting out in soft/loose soil complete all as specified and directed.
24Excavation in trenches not exc. 1.5M wide and exc.1.5M & upto 3.0M depth for foundation of stay/ pole and etc and getting out in soft/loose soil complete all as specified and as directed.
25Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in soils complete all as specified and directed.
26Removing excavated material (soils) n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
27M & L in repair for dry sand cushioning to underground cables 8cm thick before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and directed. Note: Thickness of sand shall be measured after punned down.
28Supply and Laying bricks, common burnt clay building bricks, sub class 'B' of size 230 x 115 x 75 mm laid across in trenches for cable protection complete all as specified and directed.
29Cutting the existing road/PCC surface straight by manual, depth and width not less than 1 mtr below ground level for passing of under ground cable and filling back with excavated soil upto 75% road portion and 25% shall be made good with plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate and inserting 80/40 mm bore GI pipe complete all as specified and directed.
30M&L in repair Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. .The earting pit should be cover with pcc(1:2:4 , B1) cover ,of 450 x 450 mm complete all as specified and directed.
31S&F in replacement PVC insulated unsheathed/sheathed cable with stranded Aluminium conductor 1100 Volts grade, flat twin core service cable of size 4 Sqmm conforming to IS:694/1990 with latest amendments ISI including disconnecting/taking out existing unsv/damaged old service cable complete all as specified and directed.
32Same as item No 31 above but of size 6 Sqmm.
33Same as item No 31 above but of size 10 Sqmm.
34S&F in replacement hot press moulded SMC junction/ terminal box of size with internal diamensions of 200 x 140 x 95 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/glands, fixed on pole by means of clamps made out of MS flat iron of size 25mm x 3 mm 2 Set including dismantling of old unserviceable all as specified and as directed.
35Supply and laying in replacement GI tubing light grade of size 40 mm for cable protection on road/drain/floor/pole including necessary clamps with FI 40x4mm complete all as specified and directed.
36Supply and laying in replacement GI tubing light grade of size 50 mm for cable protection on road/drain/floor/pole including necessary clamps with FI 40x4mm complete all as specified and directed.
37Supply of aluminium cable lugs of following sizes :-
3816 to 25 Sqmm Size
3935 to 50 Sqmm Size
4070 to 95 Sqmm Size
41120 to 150 Sqmm Size Please Enable Macros to View BoQ information
42120 to 150 Sqmm Size Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56904654
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 43 Lakhs
LAST DATE 28-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair Maintenance Of Lt Fp Jbs Pole Box Apfc Panels Voltage Stabilizer High Mast Area Lighting Pump House Power House Store Of Em Installation At Danapur Under Ge Danapur Cantt
Basic Detail
Tender No CA NO GE/DNR/T-49 of 2026-27
Bidding Type Tender
Location
City Patna
State Bihar
Key Dates
Publish Date 07 Aug 2026
Submission Date 28 Aug 2026
Open Date 04 Sep 2026
Finance
Tender Value 43 Lakhs
Tender Fee 500
EMD 86000
Exemption Available
Document List
a5b7bec0-5672-4f9d-b51c-eb8b724ec792.html
BOQ_877671.xls
Credit9085.pdf
ParticularSpecification9085.pdf
Tender9085.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 28, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Sep 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

a5b7bec0-5672-4f9d-b51c-eb8b724ec792.html

xls

BOQ_877671.xls

pdf

Credit9085.pdf

pdf

ParticularSpecification9085.pdf

pdf

Tender9085.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders