Tender For Repair/Replacement Of External Electrification Work, Lt Switchgear In Lt Panel And Feeder Pillar Box Including Ug Cable And Other Connected Works At Old Navy Nagar Under Ge(Nw) Navy Nagar
Tender Value
45 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
5 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement Of External Electrification Work, Lt Switchgear In Lt Panel And Feeder Pillar Box Including Ug Cable And Other Connected Works At Old Navy Nagar Under Ge(Nw) Navy Nagar
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exc 1.5 mtr wide and not exc1.5 mtr in depth for laying of cables etc. in any type of soil and getting out all as specified and directed by Engineer-in-Charge. Note : Rate includes removing of paver blocks carefully and stack properly for refixing after laying of cables . |
| 2 | Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm in soils. |
| 3 | Removing excavated material from the site of work and transporting out of Station/site of work suitable to the contractor all as specified. |
| 4 | Material and labour for 60 mm thick coloured interlocking paver tiles/ blocks, lacquer finish of size 250x250 mm having compressive strength of 35N/Sqmm, zig-zag (uni-paver) shape in flooring tested as per IS : 15658-2006, complete as specified and directed. |
| 5 | Material and labour for layer of 50 mm thick natural river sand bed under floors or in foundation or under paver blocks including watering and consolidation complete as specified and directed. |
| 6 | Cutting existing road surfaces or hard standing 0.45 mtr depth (22 thick comprising bituminuous topping) for laying of pipes/cables and making good disturbed surfaces to match with existing surfaces. |
| 7 | Material and labour for cement concrete type C-2, 1:3:6 (40mm graded stone aggregate), for coping and finished surface without using extra cement. |
| 8 | Supplying and laying with commissioning and testing XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of size 400 sqmm 3.5 core laid in trenches, passing through pipes, fixed on walls complete including connecting properly by means of thimbles and taking out old u/s damaged cables. |
| 9 | All as per Item No-8.00 here in before but of sizes, 300 sqmm, 3.5 core. |
| 10 | All as per Item No-8.00 here in before but of sizes, 240 sqmm, 3.5 core. |
| 11 | All as per Item No-8.00 here in before but of sizes, 185 sqmm, 3.5 core. |
| 12 | All as per Item No-8.00 here in before but of sizes, 150 sqmm, 3.5 core. |
| 13 | All as per Item No-8.00 here in before but of sizes, 120 sqmm, 3.5 core. |
| 14 | All as per Item No-8.00 here in before but of sizes, 95 sqmm, 3.5 core. |
| 15 | All as per Item No-8.00 here in before but of sizes, 70 sqmm, 3.5 core. |
| 16 | M&L for 110mm dia High density poly-ethylene pipes (HDPE) of pressure 6 kgf/cm2 pipe, for road crossing of cable or for cable protection laid in trenches or above ground surface and taking out old u/s damaged old one. all as specified and directed. Make- Dutron/Prince/National/Supreme. |
| 17 | All as per Item No-16.00 here in before but of HDPE sizes 90mm. |
| 18 | All as per Item No-16.00 here in before but of HDPE sizes 75mm. |
| 19 | M&L for GI pipe ,light grade 100mm dia for road crossing or in hard standing for protection of cable above or under ground surface including taking out old one all as specified and directed. |
| 20 | M &L for DWC (Double wall Corrugated) HDPE Pipe including accessories for road crossing of Size 100/110 mm including taking down old one. |
| 21 | M&L for feedder pillar box (size 1.0 x 0.8 x 0.3 Mtr) factory made pedestal cubical double door outdoor type, CPRI approved, modular construction fabricated out of 3.15 mm thick MS sheet, epoxy powder coated to give superior finish, totally enclosed, dust and vermin proof with locking arrangement (compartment wise) front & back side opening system including rain shed 15 cm all around, platform mounted having minimun clearance of 450 mm above ground level suitable for 415 Volts 3 phase 4 wire system 50 Hz supply, having ETP grade copper busbar strip (three phase & neutral) duly tapped in colour coded FRP sleeves install on porcelain /epoxy insulator, floor mounted type based on angle iron frame and legs 40x40x5 mm thick and having locking arrangement with 50 mm lock make Navtal or Harrison with three keys and including grouting of panel with necessary PCC work incl taking down old one complete all as specified. The scope of work including provision of housing the following accessories:-Incoming:(i) MCCB 200 Amp 4 pole 36 KA 415 V with thermal magnetic release, Ics=100% Icu. - 01 No. Make: Schneider, L&T or Legrand.(ii) Indicating lamp LED type with holder key flush mounted, Red, Yellow, blue with toggle switch - 1 set ( set of three) as in incoming phases.Outgoing:(i) MCB TP 63A, 10kA, 415V, C curve. - 01 No. Make: Schneider, L&T or Legrand.(ii) MCB SPN 25A, 10KA, 415V, C curve. - 14 No. Make: Schneider, L&T or Legrand.(iii) Analog time switch 3P Module, 24 hours program, programmable every 15 min., backup of 100 hours, current capacity 16A for ON/OFF controlling of security lights - 01 No. Make: Schneider, L&T or Legrand.(iv) Power contactor 3 pole AC, with 240 volt coil, 32 Amp rating conforms to IS / IEC 60947-4-1 for ON/OFF controlling of security lights - 01 No. Make: Schneider, L&T or Legrand.(v) Copper bus bar strips made of copper of size 40x5mm having no.s of hole for connecting of outgoing cables - 04 Nos |
| 22 | Supply, installing, testing and commissioning of LT feeder pillar box factory made cubical outdoor type, slopy canopy fabricated out of 3.15mm thick CRCA sheet with angle iron base frame made of 40x40x6mm, 45cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415V 3 phase 4 wire weather proof with IP-66 protection, with separate hinge door for each compartment for incoming and out going MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with copper busbar (TPN), suitable double compression copper cable glands complete in all respect for bay work station and including provn of the following:- (a) MCCB 400A, 36KA, FP withThermal magnetic release,lcs=100% lcs -01 Nos, (b) MCCB 200A, 25KA, FP withThermal magnetic release,lcs=100% lcs -01 Nos, (c) MCCB 100Amp,16KA, FP with Thermal magnetic release, lcs=100% lcs-04 Nos, (d) MCCB 63Amp,16KA, 4P with Thermal magnetic release, lcs=100% lcs-03 Nos(e) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of (f) Phase indicator lamp R,Y & B (Set of 3)- 01 Set(g) Analog Time switch Micro Rex QT31 - 01 Nos(h) Power Contactor 63A, 4 NO Contactor - 01 Nos(j) S&F Copper Bus bar 600Amps of suitable size, all are in equal size - Set(R,Y,B,N)(k) S & F sheet metal enclosure with plug , socket and MCB 20 Amps complete all as direcred. |
| 23 | All as per Item No 22.00 above but comprising of the following :-(a) ACB 800A, 50KA, FP withThermal magnetic release,lcs=100% lcs -01 Nos,(b) Change over switch 800A, 50KA, FP -01 Nos(c) MCCB 630A, 36KA, FP withThermal magnetic release,lcs=100% lcs -01 Nos, (d) MCCB 100Amp,25KA, FP with Thermal magnetic release, lcs=100% lcs-05 Nos, (e) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of (f) Phase indicator lamp R,Y & B (Set of 3)- 01 Set(g) S&F Copper Bus bar 1200Amps of suitable size, all are in equal size - Set(R,Y,B,N)(h) S & F sheet metal enclosure with plug , socket and MCB 20 Amps complete all as direcred.Note: All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engineer-in-Charge. |
| 24 | All as per Item No 22.00 above but comprising of the following :-(a) ACB 800A, 50KA, FP withThermal magnetic release,lcs=100% lcs -02 Nos, (b) Change over switch 800A, 50KA, FP -01 Nos(c) MCCB 100Amp,25KA, FP with Thermal magnetic release, lcs=100% lcs-05 Nos, (d) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of (e) Analog Time switch Micro Rex QT31 - 01 Nos(f) Power Contactor 63A, 4 NO Contactor - 02 Nos(g) Phase indicator lamp R,Y & B (Set of 3)- 02 Set(h) S&F Copper Bus bar 1200Amps of suitable size, all are in equal size - Set(R,Y,B,N)(j) S & F sheet metal enclosure with plug , socket and MCB 20 Amps complete all as direcred. |
| 25 | Supply, install, testing and commissioning of Indoor Feeder Panel cabin mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and copper bus bar(All in equal size), top and bottom cable entry with proper size glands including disconnecting cable connections and fixing & connecting in new installed panel with provisions of thimble/lugs and making provisions of vision glasses for meter readings, one spare MCCB compartment, and including PCC on 1:2:4 type B-1 for fixing Panel incl taking down old one complete all as specified and as directed comprising of the following :-(a) MCCB 630 Amps, 4 Pole, 36 KA, thermal magnetic release, Ics=100% Icu - 01 Nos(b) MCCB 250 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 01 Nos (c) MCCB 160 Amps, 4 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 09 Nos(d) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of (e) Phase indicator lamp R,Y & B (Set of 3)- 01 Set(f) S&F Copper Bus bar 800Amps of suitable size, all are in equal size - Set(R,Y,B,N) |
| 26 | S&F in repair, MCCBs in existing FP/panel, connecting to bus-bar with all connecting accessories and modification in busbar (if Necessary), connection complete and testing after completion, all as specified and directed, of following capacities :- |
| 27 | MCCB 63 Amps,16 kA,FP, 50 Hz,Thermal magnetic release,lcs=100% lcu. |
| 28 | MCCB 100 Amps,16 kA,FP,50 Hz,Thermal magnetic release,lcs=100% lcu. |
| 29 | MCCB 160 Amps,25 kA,FP,50 Hz,Thermal magnetic release,lcs=100% lcu. |
| 30 | MCCB 200 Amps,25 kA,FP,50 Hz,Thermal magnetic release,lcs=100% lcu. |
| 31 | MCCB 250 Amps,36 kA,FP,50 Hz,Thermal magnetic release,lcs=100% lcu. |
| 32 | MCCB 320 Amps,36 kA,FP,50 Hz,Thermal magnetic release,lcs=100% lcu. |
| 33 | MCCB 400 Amps,36 kA,FP,50Hz,Thermal magnetic release,lcs=100% lcu. |
| 34 | MCCB 630 Amps,36 kA,FP,50Hz,Thermal magnetic release,lcs=100% lcu. |
| 35 | ACB 800 Amps,50 kA,FP,50Hz,Thermal magnetic release,lcs=100% lcu. |
| 36 | ACB 1000 Amps,50 kA,FP,50Hz,Thermal magnetic release,lcs=100% lcu. |
| 37 | ACB 1250 Amps,50 kA,FP,50Hz,Thermal magnetic release,lcs=100% lcu. |
| 38 | ACB 1600 Amps,50 kA,FP,50Hz,Thermal magnetic release,lcs=100% lcu. |
| 39 | Material & Labour for earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6 mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full length of earth plate, GI medium grade pipe 40 mm bore protection pipe upto test point, 20mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, excavation , earth work in any type of soil, removal of excavated soil and returning filling in all as required at site complete all as specified in plate No 3 of SSR Part-I and all as specified or indicated including testing on completion incl taking down old one complete all as specified. NOTE :-Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth wire upto 7.5 m long for connecting to test point etc. all as required at site for complete earthing. |
| 40 | M&L scrapping old worn out paint from complete indoor/outdoor panels (area exc 5 sqm but not 8 Sqm ) and painting with one coats of synthetic enamel paint (incl front door in side and indl compartment outer side etc also) over a coat of primer and spray painting complete including fixing sticker danger sign board suitable for LT panel board all as specified and as directed by engr-in-charge. |
| 41 | M&L scrapping old worn out paint from complete street light/deco light poles and painting with one coats of synthetic enamel paint over a coat of primer and spray painting complete all as specified and as directed by engr-in-charge. |
| 42 | M&L for shifting of LT panel of any size with all accessories and fixing it to other location as directed by Engr-in-Charge at site, connecting cable connection with connecting accessories, incl foundation in PCC 1:3:6 type C2 all as specified and directed. |
| 43 | M&L for straight through joint, heat shrinkable tubular type of size 25 to 50 sqmm,3.5 core, 1100 volts grade complete all as specified and directed.Make- M-Seal/3MDenson |
| 44 | All as per Item No-31.00 here in before but of sizes, 70 to 120 sqmm, 3.5 core. |
| 45 | All as per Item No-31.00 here in before but of sizes, 150 to 185 sqmm, 3.5 core. |
| 46 | All as per Item No-31.00 here in before but of sizes, 240 to 300 sqmm, 3.5 core. Please Enable Macros to View BoQ information |
| 47 | All as per Item No-31.00 here in before but of sizes, 240 to 300 sqmm, 3.5 core. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 8 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender