Defence Statutory Bodies & Commissions/Committees Closing in 33 days TDR #56904642

Tender For Affected Infrastructure / Services, Upgradation Of Security Infrastructure And Equal Value Infrastructure At Nauveer Nagar, installation Dwarka, Okha

Issued by Statutory Bodies & Commissions/Committees · Porbandar, Gujarat
Tender Value
10.30 Crore
Estimated cost
Bid Submission
10 Sep 2026
33 days left
EMD
8.40 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Porbandar → Gujarat
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Affected Infrastructure / Services, Upgradation Of Security Infrastructure And Equal Value Infrastructure At Nauveer Nagar, installation Dwarka, Okha

BOQ

Name of Work:- AFFECTED INFRASTRUCTURE / SERVICES, UPGRADATION OF SECURITY INFRASTRUCTURE AND EQUAL VALUE INFRASTRUCTURE AT NAUVEER NAGAR, INS DWARKA, OKHA
Sl. No. Item Description
1SCHEDULE-'A' Part - I (BUILDINGS & STRUCTURES)Total of Sch-'A' Part-I B/F from serial page No. 26
2SCHEDULE-'A' PART-II (SITE CLEARANCE, EXCAVATION & EARTHWORK) Total of Sch-'A' Part-II B/F from serial page No. 27
3SCHEDULE-'A' PART-III (DEMOLITION & DISMANTLING)Total of Sch-'A' Part-III B/F from serial page No. 29
4SCHEDULE-'A' PART-IV (INTERNAL WATER SUPPLY)Total of Sch-'A' Part-IV B/F from serial page No. 30
5SCHEDULE \\"A\\" PART-V (EXTERNAL WATER SUPPLY)Total of Sch-'A' Part-V B/F from serial page No. 31
6SCHEDULE \\"A\\" PART-VI (EXTERNAL ELECTRIC SUPPLY) Total of Sch-'A' Part-VI B/F from serial page No. 32
7SCHEDULE \\"A\\" PART-VII (INTERNAL ELECTRIFICATION)Total of Sch-'A' Part-VII B/F from serial page No. 34
8SCHEDULE \\"A\\" PART-VIII (FIRE FIGHTING)Total of Sch-'A' Part-VIII B/F from serial page No. 37
9SCHEDULE \\"A\\" PART-IX (LIGHTNING PROTECTION)Total of Sch-'A' Part-IX B/F from serial page No. 39
10SCHEDULE \\"A\\" PART-X (ROAD, PATH, HARD STANDING & CULVERT)Total of Sch-'A' Part-X B/F from serial page No. 40
11SCHEDULE \\"A\\" PART-XI (SEWAGE DISPOSAL)Total of Sch-'A' Part-XI B/F from serial page No. 41
12SCHEDULE \\"A\\" PART-XII (AREA DRAINAGE)Total of Sch-'A' Part-XII B/F serial page No. 43
13SCHEDULE \\"A\\" PART-XIII (RAIN WATER HARVESTING)Total of Sch-'A' Part-XIII B/F from serial page No. 44
14SCHEDULE \\"A\\" PART-XIV (FENCING GATE COMPOUND WALL)Total of Sch-'A' Part-XIV B/F from serial page No. 45
15SCHEDULE \\"A\\" PART-XV (DG SET)Total of Sch-'A' Part-XV B/F from serial page No. 47
16SCHEDULE \\"A\\" PART-XVI (RO)Total of Sch-'A' Part-XVI B/F serial page No. 48
17SCHEDULE \\"A\\" PART-XVII (VOLLEY BALL COURT)Total of Sch-'A' Part-XVII B/F from serial page No. 49
18SCHEDULE \\"A\\" PART-XVIII (BASKET BALL COURT)Total of Sch-'A' Part-XVIII B/F from serial page No. 50
19SCHEDULE 'A' PART -XVII (MISCELLANEOUS AND SPECIAL ITEMS OF WORK)
20EXTERNAL ELECTRIC SUPPLY
21Taking out / dismantling of old Street Light/Flood Light/Post Top Lantern after disconnect from power supply and elemental from foundation dressing of ground surface zone all as specified and directed.
22Taking out / dismantling of old Street Light/Flood Light/Post Top Lantern after disconnect from power supply and all as sent to complete.
23Supply and Repair/Replacement of hot press moulded SMC junction box, SMC base and SMC door, fixed with hinge right side, sintex box of size 205 x 255 x 112mm with 10 Amps MCB SP, Bus Bar power connector for RYB-N fixed on epoxy base with the help of MS nuts, bolts and MS clamps—2 Nos. of size 40mm x 5mm thick, including fixing arrangement on pole complete all as specified and directed.
24Supply and Repair/Replacement of hot press moulded SMC junction box, SMC base and SMC door, fixed with hinge right side, sintex box of size 155 x 210 x 92mm with 10 Amps MCB SP, Bus Bar power connector for RYB-N fixed on epoxy base with the help of MS nuts, bolts and MS clamps—2 Nos. of size 40mm x 5mm thick, including fixing arrangement on pole complete all as specified and directed.
25Taking out of old UG XLPE Cable after disconnect from power supply and disconnect of all connections complete.
26Taking out old Galvanized steel high mast lighting system of 16 meters with 2/3 wire rope system and its accessories after disconnect from power supply and dismantlement from foundation dressing of ground surface complete all as specified and directed.
27Supply and installation of galvanized steel high mast lighting system (16 meters), comprising the following:(i) Supply of 16M high mast shaft in two sections, suitable for wind speed, with head frame, winch mounting bracket, and luminaries carriage suitable to install 08 Nos. luminaries in symmetrical arrangement. (Bajaj)(ii) Supply of raising/lowering system comprising double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightning finial, and counterweight. (Wiring material from JB to individual luminaire and MCB in the base compartment are not included and are a part of installation).(iii) Supply of foundation bolts manufactured from special steel, along with nuts, washers, anchor plate, and common template.(iv) Supply of LED-type single dome aviation obstruction light.(v) Supply of outdoor stand-mounted feeder pillar with 63A TPN MCB incomer, single dial time switch, 63A TP contactor for the automatic switching of luminaries, power tool control with 2 Nos. 16A contactors, and raise/lower push button; incoming 35 sq.mm and outgoing 16 & 2.5 sq. mm terminals.(vi) Erection Part:(a) Construction of shallow foundation with M20 grade concrete for the high mast, considering the safe soil bearing capacity at site as 10T/sqm at 2-metre depth, with all materials and labour.(b) Erection of the high mast with the help of suitable tools and plants, wiring of luminaries with all wiring materials like PVC insulated, PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq.mm, lugs, MCB, and all labour. (HYDRA SHALL BE ARRANGED BY CONTRACTOR).(c) Installation of the mast feeder pillar by grouting the stand in concrete.
28Taking out of old high mast / street light panel, including all its parts (i.e., MCBs, contactor, switches, etc.) from foundation, complete all as specified and directed.
29Supply and fix LED flood light, 300 watt, 230 V AC outdoor type with thermal management in multiple optics, equipped with IP66 protection, impact and corrosion resistant, complete with driver and lamp, all as specified and as directed.
30Supply and fixing of new generation energy-saving and environmentally friendly long-life LED flood light (150 W, IP 66, 230 V) by connecting the electrical connection and tightening the nuts, bolts, and clamps; light connected with 80mm dia GI pole (medium grade, 8mtr height) with suitable foundation, 30cm coping of pole, and 30cm grouting with PCC foundation, complete all as specified and directed.
31Supply and fixing of new generation post-top energy-saving, environmentally friendly, long-life, aesthetically designed luminaire with symmetrical light distribution; spun aluminium landscape luminaire with high-power LED as light source (Coral opal), IP65, suitable for pole dia 76 mm with 25 watt LED lamp, complete all as specified and directed by Engineer-in-Charge.
32Supply and fixing of Garden Bollard light (BGBOM 650 8W LED Bollards light). Die-cast aluminium graphite grey powder-coated GI pipe housing, mushroom-shaped opal acrylic diffuser, fixed in die-cast aluminium base for pleasant light output. LED mounted on die-cast aluminium base, IP-65, 240 Volt. Luminaire is provided with base plate and fixing holes for directly mounting on the concrete pedestal, complete all as specified and directed. Catpart No. BAMBOOBL8WLED857PSYMTOPCM of Havells Make/Bajaj/C&S/Wipro.
33Supply, laying, and testing PVC insulated, PVC-sheathed electric control cables (heavy duty) with stranded copper conductor of size 4 sq mm, 3 core, 1100 Volts grade, complete all as specified and directed.
34Supply and fix for 100 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 25 KA, with adjustable thermal and fixed magnetic setting system against overload and short circuit conditions, including neutral adjustment; capacity suitable for existing panel board, complete all as specified and directed.
35Supply and fix for 160 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 25 KA, with adjustable thermal and fixed magnetic setting system against overload and short circuit conditions, including neutral adjustment; capacity suitable for existing panel board, complete all as specified and directed.
36Supply and fixing of new generation post-top energy-saving, environmentally friendly, long-life, aesthetically designed luminaire with symmetrical light distribution; spun aluminium landscape luminaire with high-power LED as light source (Coral opal), IP65, suitable for pole dia 76 mm with 25 watt LED lamp, complete all as specified and directed by Engineer-in-Charge.
37Taking out of old high mast/street light panel, including all its parts (i.e., MCBs, contactor, switches, etc.) from foundation, complete all as specified and directed.
38Supply, installation, testing & commissioning of floor-mounted factory-made cubicle LT panel (outdoor type), suitable for outdoor use, made of 3.15 mm thick CRCA sheet. CPRI approved, IP-54, duly painted with epoxy-based powder-coated paint. Includes base channel, interconnection control wiring, nameplates for each switchgear, danger plate, earth bus bar, as per IS 5039. Comprising compartments for each feeder and its accessories, cable gland with hinged door, bus chamber with bolted door, etc. Dust and vermin-proof construction, attractive powder-coated finish. Internal wiring for the control circuit with copper cable 2.5 Sq.mm. Comprising the following (including necessary PCC and excavation work all as specified and directed): (Make: CPRI Approved) (For Street Light)
39(a) Aluminium bus bar 200 Amps TPN-1 set
40(b) MCCB 4 Pole 63 Amps., 25 KA - 01 No. (incomer)
41(c) MCB TPN 63 Amps, 10KA - 02 No. (outgoing)
42(d) MCB 32 Amps SPN ,10 KA - 02Nos (Outgoing)
43(e) Power Contactor 3 Pole 63 Amps -1
44(f) Timer switch 415 Volts 20 Amps- 01 No.
45(g) Indicating lamp LED Type-RYB-01 Set
46(h) Digital Multifunctional Meter VAF+ PF Meter - 01 No
47Supply, installation, testing, and commissioning of weather and vermin-proof L.T. panel, factory-fabricated, outdoor type, totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal, enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3-phase 4-wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate, and locking arrangement consisting of sufficient number of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin, etc. Inside the enclosure, the required number of holes to be fixed with chromium-plated brass cable glands for cable entry and exit. Complete with necessary internal control wiring, minimum 2.5 Sq.mm with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/externally with approved colour, with PCC foundation and bus bar mounted on epoxy insulator. 01 Set including connecting the following: (Make: CPRI Approved) (For Sport Complex)
48(a) Aluminium bus bar 250 Amps TPN-1 set
49(b) MCCB 4 Pole 160 Amp, 25 KA - 01 No. (incomer)
50(c) MCCB 4 Pole 100 Amps 25 KA - 01 No. (outgoing)
51(d) MCCB 4 Pole 63 Amps 25 KA - 02 No. (outgoing)
52(e) MCB SPN 40Amps - 02 No. (outgoing)
53(f) Timer switch with Contactor 415 Volts 20 Amps- 01 No.
54(g) Digital Multifunctional VAF+ PF Meter - 01 No
55(h) Indicating lamp LED Type-RYB-01 Set
56Supply, fixing, and commissioning of weather and vermin-proof L.T. panel, factory-fabricated, outdoor type, totally enclosed outer cage made out of 3.15 mm thick sheet metal and inner compartments of 2.0 mm thick sheet metal, enclosure with angle iron frame of M.S. angle 50x50x6 mm suitable for operation on 3-phase 4-wire, 440 volts 50 Hz system, with hinged panel doors (covers) on two sides with handles, bottom gland plate, and locking arrangement consisting of sufficient number of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin, etc. Inside the enclosure, the required number of holes to be fixed with chromium-plated brass cable glands for cable entry and exit. Complete with necessary internal control wiring, minimum 2.5 Sq.mm with stranded copper conductor PVC insulated cables of adequate size, duly powder coated internally/externally with approved colour, with PCC foundation and Aluminium bus bar mounted on epoxy insulator. 01 Set comprising the following: (Make: CPRI Approved) (For 16DUs Bldg)
57(a) Copper bus bar of 500Amps - 04 Nos duly covered with Red, Yellow, Blue and black PVC seve/tape and fixed on DMC insulators.
58(b) S&F MCCB FP 250 Amp,415 Volt, 35 KA thermal adjustable type. (Incomming) - 01 Nos.
59(c) S&F MCCB FP 100 Amp, 415 Volt, 25 KA. (Out going) -01No.(For Fire Fighting Panel)
60(d) S&F MCB SPN 40 Amp,10 KA (Out going) - 18Nos.(For 16 Qtrs +Security Light +1 Spare)
61(e) Single phase smart energy Meter - 16 Nos
62(f) S&F multifunctional type digital meter to measure voltage, current, frequency, PF etc complete - 01 Nos
63(g) Digital Multifunctional VAF+ PF Meter - 01 No
64(h) Indicating lamp LED Type-RYB-01 Set
65Supply and lay Double Walled Corrugated (DWC) Pipes having corrugation on the outer wall and plain surface on the inner wall confirming to IS14930 (Part-II) for protection of UG cables size 50 mm outer dia laid in trenches/ road/ drain or fixed along wall, poles or laid under floor complete all as specified and directed.
66Supply and lay Double Walled Corrugated (DWC) pipes, having corrugation on the outer wall and plain surface on the inner wall, conforming to IS 14930 (Part II) for protection of UG cables, size 65 mm outer dia, laid in trenches/road/drain or fixed along wall, poles or laid under floor, complete all as specified and directed.
67INTERNAL ELECTRIFICATION
68S & F modular metal flush box of following modules flushed in wall and making good surface complete all as specified and directed:
698 Module
70Supply and fixing integrated LED batten 20 Watt, 4 feet long, full white in Engineering plastic batten with white acrylic cover with built in electronic driver, pre-wired and connecting up with twisted twin core flexible copper wire of 0.5 sqmm from ceiling rose to connector of fitting along with provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings complete all as specified and directed.
71Supply and fix Wall Fan made of PVC body AC single Phase. 230V of size 400 mm sweep with, blades and frame complete with louvers shutter, Copper winding complete all as specified and directed by Engineer-in-Charge.
72Supply and fix TV co-axial socket 1 module complete with all accessories all as directed.
73Supply and fix telephone/communication network sockets(Jack type) RJ 45 with shutter 1 module with cover plate complete with all accessories all as directed.
74Supply and fixing 150 W LED Flood Light SMD type fitting in diecast al housing with heat resistant toughened glass, made of aluminium alloy lighting colour cool white round shape IP66 protection complete with all accessories prewired and including connecting up with twin core twisted flexible copper conductor cable of suitable size etc all as specified and directed.
75EXTERNAL WATER SUPPLY
76Making connection of CPVC/PP-R distribution branch with GI main of following sizes by providing and fixing tee including cutting and making fusion joint etc. of size 80 mm complete all as specified and as directed.
77Supply and fixing of PP-R Gate Valves (Brass Insert) of 110 mm bore, complete all as specified and as directed.
78Supply, testing and commissioning of monoblock pump set suitable for 415 V, 50Hz, 3-phase system, having capacity 5 HP (1W+1S) with 2900-3000 RPM, high efficiency and energy saving, of minimum head 22-30 Mtr and delivered 11 LPS, with cast iron body and impeller and CED coating; pump all as specified and as directed.
79Supply and fixing of DOL starter, fully automatic, suitable for 415 V AC, suitable for 05 HP motor, type MK-1, complete with sheet-steel enclosure, complete all as specified and directed.
80S&F 3 Pole MCCB, 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA for fixing in existing panel of pump house for starter, complete all as specified.
81Supply and fixing of 6 sqmm 3-core electric supply cable, PVC insulated copper cable, PVC round sheathed submersible cable, multicore industrial cables for voltage grade upto 1100 V, complete with copper lugs, all as specified and directed by Engr-in-Charge.
82Construction of valve pit 1000 mm x 1000 mm x 900 mm internal dimensions, including PCC foundation 1:3:6, brickwork in Class B bricks, coping in PCC 1:2:4, cover and frame in angle iron 40 mm x 40 mm x 6 mm with 2mm thick cover, etc., complete with locking arrangement, all as specified and directed at site.
83DG SET
84Supply, installation, testing and commissioning of silent diesel engine-driven generating set of capacity 40 KVA, 415 volts, 3-phase 4-wire, engine as per IS:10001/10002 and alternator as per IS:13364, complete with relay panel and switchgears for automatic starting on main failure, control panel having meter and soundproof canopy as per CPCB IV+ norms, and complete foundation, etc. Make: Kirloskar / Cummins.(A) Diesel Engine: The engines are rated at 1500 RPM, BHP not less than 74.1 HP, and conform to ISO 8528 specifications; radiator cooled, four-stroke and multi-cylinder, conforming to BS 5514 / ISO 3046 with the following accessories:(a) Electrical starter motor 12 V DC - 01 No(b) Battery charger 12 V 88 AH DC - 01 No(c) In-line Bosch fuel system with mechanical G2(d) Dual spin-on fuel filter(e) Spin-on lube oil filter elements(f) Residential silencer(g) Dry type air cleaner(h) Recovery bottle(j) Shut-off coil with safeties for LLOP / HWT(k) Flywheel and flywheel housing(l) First fill of lube oil and coolant(m) Radiator, air-to-air after-cooler, pusher fan & fan drive arrangement
85(B) Alternator: Brushless type, screen-protected, revolving field, self-excited, self-regulated through an AVR. The alternator is suitable for operation at 1500 RPM, 415 Volts, 0.8 PF (lagging), suitable for 50 Hz, 3-phase, 4-wire system, conforming to BS 5000 / IS 4722. The alternator has the following features:(a) ± 1.0% Voltage regulation (max) in static condition.(b) IP:23 Enclosure(c) Permissible overload of 10% for one hour in 12 hours operation.(C) Mounting Arrangement: The engine and alternator are mounted on a common MS fabricated base frame with AVM pads.(d) Leroy Somer / CG Power make, 3-Phase, 4-Wire, self-excited, self-regulated, brushless, single bearing type; Class H insulated AC generator developing 125 kVA, 415 V, 0.8 PF (lag) with IP23 protection.
86Control Panel:Control panel is 16/14 gauge sheet steel, complete with fabricated, dust & vermin-proof & internal wiring. The annunciation following protection / control / display / features are provided for the DG set:MCCB of adequate ratingIndicating lamps for DG ON & LOAD ONKey switchSet of Current TransformersSet of control fusesINTEGRATED DG SET CONTROLLER: Monitoring engine speed, oil pressure, coolant temperature, frequency, voltage, current, power, and fuel level, the modules will give comprehensive engine and alternator protection. This will be indicated on the largest back-lit LCD icon display in its class, an array of warning, electrical trip, and shutdown alarms. With a number of flexible inputs, outputs, and modules protections, it can be easily adapted to suit a wide range of applications including lighting towers with the added option for staged loading outputs. Through USB communication, both modules can be easily configured using the Configuration Suite PC Software or can be fully configured through the module's front panel editor.
87Supply, installation, testing, and commissioning of Chiller Plant Optimizer (CPO), controlled by IP-based (UL listed) Chiller Plant Controller (CPC) unit(s) having a library of factory-designed and tested algorithms to operate, supervise, and improve operational efficiency of the individual Product Integrated Controller (PIC) for each chiller, allowing dynamic interaction between the supervisory software, towers, pumps, and the chiller PIC(s) to create a complete chilled water plant system including software programming and related calibration complete all as specified and as directed. The CPO shall conform to the following technical specification / functional requirements:[i] The CPO software shall have a Perpetual Software License and shall not be subscription-based. It shall be given to the owner at the time of handover.[ii] The CPO software shall provide a web-based platform for monitoring, controlling, and optimizing HVAC systems. It must support BACnet/IP communication, offer real-time data visualization, and allow remote access via any standard browser. The software should facilitate easy integration with existing building management systems, support data logging, and provide customizable alarms and reports. It should also enable scheduling, trend analysis, and system diagnostics without the need for additional software installations. It should support unlimited user login support.
88Supply and lay Double Walled Corrugated (DWC) pipes having corrugation on the outer wall and plain surface on the inner wall, conforming to IS 14930 (Part-II) for protection of UG cables, size 65 mm outer dia, laid in trenches/road/drain or fixed along wall, poles or laid under floor, complete all as specified and directed.
89Supply and fix Reverse Osmosis Plant (Purifier) of output capacity of 20-25 Litres per hour, complete all as specified and as directed.
90Supply and fix Voltage stabilizer for automatic operation, single-phase, naturally air-cooled, indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA, complete all as specified and directed by Engineer-in-Charge.
91LIGHTENING PROTECTION
92Supply & fix porcelain insulator for laying of lightning strip on the roof/wall to maintain distance from surface and strip of suitable size and distance between two insulators (minimum 1 m), complete all as specified and directed.
93WOODEN FLOORING (BADMINTON COURT)
94M&L for wooden flooring made of kiln-seasoned (moisture content not more than 12%) treated Maple wood, finished with min 21 mm thick and 57 to 83 mm wide pieces in random length, in tongue and groove shape. The edge of boards having finger-lock groove and bottom side with air pass groove, and pre-treated with special anti-termite and water-resistant solutions. Runners under floors made of 70x45 mm, treated with anti-termite solution, fixed on the floor with 10 mm thick air-cushioned pad, including treatment of floor with vapour barrier solutions.
95AREA DRAINAGE
96M&L for walling of Porbandar stone masonry, well-bonded and solidly hearted, built in CM 1:6, complete all as specified. (Area Drainage - 124.56 Cum; Fencing Gate at Compound wall - 66.67 Cum)
97FIRE FIGHTING
98Supply and fixing of Fire Alarm Addressable control panel complying with BS EN 54 single loop panel with 99 detectors & 99 modules & up to 200 detectors and modules per loop, complete all as specified and directed.
99Supply and fixing of Escape light, complete all as specified and directed.
100Supply, laying of multi-stranded copper conductor PVC-insulated and unsheathed FRLSH cable (2 core, 1.5 sqmm), ISI marked, complete all as specified and directed.
101Supply and installation at approved location of approved make Fire sand bucket of 24 gauge galvanized steel sheet; each set shall have 4 buckets with stand & shovel, etc., and consist of the following fire extinguishers:(a) Fire Extinguisher, water stored pressure type (5 liters) - 01 No(b) Fire Extinguisher Dry chemical Powder, 5 Kg (ABC) Type - 01 No(c) Fire Extinguisher CO2, 5 Kg (Light Wt Squeeze grip type) - 01 No
102Supply and fixing of Non-Return Valve (size 25 mm), complete all as specified and directed.
103Supply and fix starter suitable for up to 6 HP motor, type MK-1, complete with sheet-steel enclosure, complete all as specified and directed.
104S & F Fire extinguisher water CO2/stored pressure type (5 ltr capacity, IS:940/6234), complete.
105S & F Fire extinguisher Dry chemical powder type (ABC), 5 Kg (IS: 2171/13849 capacity), complete.
106S & F Fire extinguisher CO2 (5 Kg capacity, IS-2878), complete.
107Supply and fixing of switching mode power supply (230 Volts AC to 24 Volt DC converter) from main DB to MCP and Hooter point, complete all as specified and directed.
108BASKET BALL COURT
109M&L for synthetic acrylic flooring 5mm thick for basket ball court including marking of lines/ demarcations and all other requisites complete all as specified and directed.
110Basketball stand post and fiber sheet board & bracket, etc., complete all as specified & shown on drg. MS poles shall be of portable type with powder coating, comprising MS weight trolley, fiberglass board (22 mm thick), ring & net, etc.
111VOLLEY BALL (COURT)
112M&L for synthetic acrylic flooring, 5 mm thick, for volleyball court, including marking of lines/demarcations and all other requisites, complete all as specified and directed.
113S & F volleyball nets, having a surface height of 39” (1 m) from top to bottom, constructed with polypropylene or nylon netting with a mesh size of 3.9” (10 cm), capped with stiff headbands along the perimeters, and with all necessary requirements of the volleyball net.
114FENCING GATE COMPOUND WALL
115S & F for galvanized iron posts and struts in fencing, including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh, etc.) including all necessary drilling, bolting or riveting, etc., and similar work, complete all as specified and directed.
116Providing and fixing galvanized iron (GI) perforated sheet, zinc-coated for corrosion resistance, of thickness 1.00 mm, with hole size 5 mm, spacing 50 mm c/c, weight of sheet 4 to 5 kg per sqm, complete all as specified and directed.
117S & F PVC-coated chain link fencing, make 'NELTON' of standard quality, 2 mm dia galvanized wire, 1 mm thick PVC coating, 100x100 mm size square/spacing, fixed complete all as specified and directed by Engr-in-Charge.
118S & F bitumen dip concertina coil, punched tape, 2.60 mm dia high tensile spring steel wire, dia of coil 610 mm; when stretched, the length shall be 6 m in one coil and tied to barbed wire with and including provision of steel slips @ 5 clips spiral in one row, complete without coating, all as specified and directed by Engr-in-Charge.
119ARBORICULTURE
120Supply and planting of the following species of well-grown (two-year-grown) healthy tree saplings with good root system and height as mentioned below, and M&L: excavating a pit of size 450 mm x 450 mm x 450 mm, refilling with sweet earth mixed with manure in the ratio of 3:1 by volume, in addition to 2 kg of neem khali/cake and cow dung, including watering and spraying pesticides, etc., all as specified and directed by the Engineer-in-Charge.Note: Supply only of (a) vermicompost, (b) sweet earth, and (c) insecticides and pesticides, etc., shall be measured and paid separately under relevant items.
121Sitaphal (4 feet to 5 feet)
122Bouiganvillea (4 feet to 5 feet)
123Ashoka (4 feet to 5 feet)
124Palm (4 feet to 5 feet of Different species types)
125Mango (4 feet to 5 feet)
126Guava (4 feet to 5 feet)
127Cheeku (4 feet to 5 feet)
128Neem (4 feet to 5 feet)
129Jammun (4 feet to 5 feet)
130Coconut (4 feet to 5 feet)
131Supply only approved vermicompost of best quality, complete all as specified.
132Supply and stacking of well-decomposed cow dung, including royalty, loading, unloading, transportation, and stacking at site. Note: for the purpose of payment, the stack measurement shall be reduced by 10% for voids.
133Removal of masonry waste and other undesirable material and its disposal away from site as directed by the Engineer-in-Charge.
134Supply of good sweet earth for tree plants and for other landscaping works, brought from outside MD land, and including royalty and carriage for all leads.
135Supply of insecticides, pesticides, etc., at site store in dust/liquid form, complete.
136Chloropyriphos-20% EC
137Supply of neem khali in form of cake
138Supply and stacking gypsum 50 kg bag, complete all as specified and directed by the Engineer-in-Charge.
139Supplying and stacking DAP at site, complete all as specified and directed.
140Regular maintenance of trees, specimen plants, and other similar plants till the completion of the 3-year maintenance period, including replacement of dead plants of the same height, and including watering, training, pruning, hoeing, weeding, stacking, insect/pest management, cleaning of nearby area, and disposal of waste away from site. Quarterly enrichment with manure @ 0.015 cum per pit with a minimum of 3 visits per month or as directed by the Engineer-in-Charge. Note: manure shall be measured and paid separately in relevant items.
141Supply and laying/planting of green, well-grown healthy lawn in rows with good root system, pitching @ 150 mm c/c, including surface excavation, removing waste soil, laying/spreading one layer (minimum 15 cm) of black cotton soil mixed with sweet earth and jaivik manure, including watering and spraying pesticides, etc., as specified, including replacement of dead grass and regular maintenance till the completion of the maintenance period of one year, complete, and minimum 3 visits per month, including watering as specified and directed by the Engineer-in-Charge.
142Regular maintenance of lawn for 1 (one) year as given in item No. 7 above, including watering, insect/pest management, mowing of grass, brooming, hedge cutting, uprooting of undesired vegetation/weeds, etc., and disposal of the same away from site. Spreading of manure twice in a year (7 mm thick average layer) as directed by the Engineer-in-Charge (manure, pesticides, etc., shall be measured and paid separately).
143S&F tree guards made of welded steel wire fabric (150x100), supplied and fixed complete to wood or steel members and supported with flat iron (25x5x6) fillet (for securing the mesh) and three legs in angle iron (30x30x5) welded to the tree guard below, and inserting it into ground, all as specified and directed, and preparation of new surface and priming with red oxide zinc chrome and applying two coats of paint with synthetic enamel (ordinary tint), including earthwork and PCC 1:3:6 type C1, all as specified and as directed by the Engineer-in-Charge.
144Supply only 20 mm dia PVC pipe, high quality, for the purpose of horticulture.
145Supply only rotary-type sprinkler made of brass with MS stand and suitable for 20 mm dia pipe. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56904642
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 10.30 Crore
LAST DATE 10-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Affected Infrastructure / Services, Upgradation Of Security Infrastructure And Equal Value Infrastructure At Nauveer Nagar, installation Dwarka, Okha
Basic Detail
Tender No 87992/E8
Bidding Type Tender
Location
City Porbandar
State Gujarat
Key Dates
Publish Date 07 Aug 2026
Submission Date 10 Sep 2026
Open Date 12 Sep 2026
Finance
Tender Value 10.30 Crore
Tender Fee 3000
EMD 8.40 Lakhs
Exemption Available
Document List
87992Drgs.pdf
87992TenderPages.pdf
9fcde5d0-6483-45ca-ab9d-227d352e0ad9.html
BOQ_877651.xls
Tendernotice_1 (6).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 33 days
Sep 12, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 35 days

Tender Documents

Download All (ZIP) ↓
pdf

87992Drgs.pdf

pdf

87992TenderPages.pdf

html

9fcde5d0-6483-45ca-ab9d-227d352e0ad9.html

xls

BOQ_877651.xls

pdf

Tendernotice_1 (6).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders