Tender For Comprehensive Maintenance Of Sewage Installation Including Sewage Pump Motor Of Sewage Lifting Pumps Connected Control Panels And Other Allied Works At Nams.
Tender Value
42 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
15 days left
EMD
84000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Amritsar → Punjab
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Comprehensive Maintenance Of Sewage Installation Including Sewage Pump Motor Of Sewage Lifting Pumps Connected Control Panels And Other Allied Works At Nams.
BOQ
| Sl. No. | Item Description |
| 1 | Material and labour for dismantling / opening the burnt motor, rewinding the motor with super enamelled copper winding as per existing gauge including insulation material cotton tape, varnish, insulation paper, sleeves and dry and packing etc including laying out defective parts such as bearing, impeller and Mechanical oil seal and reassembling complete motor of capacity 15 HP to 20 HP complete all as specified and directed. NOTE : (a) The cost of copper winding wire of any size / gauge deemed to included in this job (b) The cost of tranportation such as vehicle, T & P and man power for taking out of faulty motor and lowering the same deemed to be included in this job (c) Replacement of spare parts shall be measured and paid under respective items. (d) Old copper winding wire will be the property of Contractor. |
| 2 | All as per item 01.00 here in before but capacity 7.5 HP to 12.5 HP . complete all as specified and directed. |
| 3 | All as per item 01.00 here in before but capacity 2 HP to 5 HP. complete all as specified and directed. |
| 4 | Supply and fixing of bearing for submersible motor & pump for 15 HP to 20 HP complete all as specified and directed. |
| 5 | All as per item 04 here in before but capacity 7.5 HP to 12.5 HP. complete all as specified and directed. |
| 6 | All as per item 04 here in before but capacity 2 HP to 5 HP. complete all as specified and directed. |
| 7 | Supply and fixing of S S impeller for 15HP to 20 HP complete all as specified and directed. |
| 8 | All as per item 07 here in before but capacity 7.5 HP to 12.5 HP. complete all as specified and directed. |
| 9 | All as per item 07 here in before but capacity 2 HP to 5 HP. complete all as specified and directed. |
| 10 | Supply and fixing of mechanical oil seal for 15 to 20 HP submersible pump complete all as specified and directed. |
| 11 | All as per item 10.00 here in before but capacity 7.5 HP to 12.5 HP. complete all as specified and directed. |
| 12 | All as per item 10.00 here in before but capacity 2 HP to 5 HP. complete all as specified and directed. |
| 13 | Supply and fixing in replacement MCB 32 Amps four pole 240 Volts, 50Hz, rupturing capacity 10 kA, C curve , conforming to IS 8828 ; complete all as specified and directed by Engineer-in-Charge. |
| 14 | Supply and fixing in replacement of MCCB 63 Amp, 4 Pole, 16 KA complete all as specified and directed by EIC. |
| 15 | Supply and fixing in replacement of MCCB 100 Amp, 4 Pole, 25 KA complete all as specified and directed by EIC. |
| 16 | Supply and fixing in replacement of MCCB 250 Amp, 4 Pole, 25 KA complete all as specified and directed by EIC. |
| 17 | Supply and fixing in replacement fan belt B 70 and suitable for 40 HP Compressor ; complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply and fixing in replacement fan belt B 52 and suitable for 20 HP Compressor ; complete all as specified and directed by Engineer-in-Charge. |
| 19 | S & F in replacement of 3 pole power contactor 40 Amp, AC 3 phase, 415 Volt, with contact ( NO-1 + NC-1) complete all as specified and directed. |
| 20 | S & F in replacement of 3 pole power contactor 18 Amp , AC 3 phase, 415 Volt with contact ( NO-1 + NC-1) complete all as specified and directed. |
| 21 | S & F in replacement of 3 pole power contactor 25 Amp, AC 3 phase, 415 Volt, with contact ( NO-1 + NC-1) complete all as specified and directed. |
| 22 | S & F in replacement of thermal over load relay 12 to 18 Amp 415 Volt complete all as specified and direcetd. |
| 23 | S & F in replacement of thermal over load relay 28 to 40 Amp 415 Volt complete all as specified and direcetd. |
| 24 | S & F in replacement of thermal over load relay 17 to 25 Amp 415 Volt complete all as specified and direcetd. |
| 25 | S & F in replacement of electronic timer for star delta starter 415 volt timing range 0 sec to 30 sec complete all as specified and direcetd. |
| 26 | Supply and fix in replacement of selector switch complete all as specified and directed by Engr in Charge. |
| 27 | Material and labour in replacement of Single phase preventor SM 301 complete all as specified and directed. |
| 28 | Supply, laying and testing Ductile Iron Pressure Pipes with spigot & socket ends of 100 mm bore class K-7 centrifugally cast conforming to IS:8329/2000 blast furnace slag cement portland cement properties suitable for push-on jointing with inside surface cement mortar lining, with internal metallic zinc coating and external black bitumen coating, duly ISI marked complete laid in trenches or under the roads, with and including Tyton rubber gasket push-on joints as per required at site, including DI fittings required at site and dismantling & taking out the old unserviceable water supply pipe line any type from the trenches complete all as specified and as directed by Engineer-in-charge.Note :- (a) Excavation & other earth work shall be measured and paid separately under relevant items. |
| 29 | Supply, laying and testing Ductile Iron Pressure Pipes with spigot & socket ends of 150 mm bore class K-7 centrifugally cast conforming to IS:8329/2000 blast furnace slag cement portland cement properties suitable for push-on jointing with inside surface cement mortar lining, with internal metallic zinc coating and external black bitumen coating, duly ISI marked complete laid in trenches or under the roads, with and including Tyton rubber gasket push-on joints as per required at site, including DI fittings required at site and dismantling & taking out the old unserviceable water supply pipe line any type from the trenches complete all as specified and as directed by Engineer-in-charge.Note :- (a) Excavation & other earth work shall be measured and paid separately under relevant items. |
| 30 | Supply and fixing in replacement of GI steel tubing 'medium grade 50mm bore including replacement of unserviceable fittings like Tee,bend,nipple,union,plug and socket etc. laid in trench/wall/floor including necessary saddles and clamps ,complete all as specified and directed. |
| 31 | M&L for repair / rewinding of electric mono block motor 15 HP including disconnecting electric connection carefully and shifting to repair workshop and opening the electric motor rotar and stater. Rewinding the motor as per existing gauge of copper winding wire, varnish, insulation sleve, retopening of coil, supply and replacement of bearing -02 Nos and welding granting and polishing of shaft as per bearing size. Reassembling the motor and shift to site and fixing and testing on load. complete all as specified and directed. |
| 32 | M & L for repair / rewinding of electric mono block motor 10 HP including disconnecting electric connection carefully and shifting to repair workshop and opening the electric motor rotar and stater. Rewinding the motor as per existing gauge of copper winding wire, varnish, insulation sleve, retopening of coil, supply and replacement of bearing -02 Nos and welding granting and polishing of shaft as per bearing size. Reassembling the motor and shift to site and fixing and testing on load. |
| 33 | Material & Labour for Repair and Rewinding of Electric induction motor 15 to 20 HP including disconnecting electrical connection carefully and shifting to workshop and opening the electric motor rotar & stater and Rewinding the motor as per existing gauge of copper winding wire, varnish, insulation sleve and reassembling the motor shift at site and connecting, testing on load ; complete all as specified and directed by Engineer-in-Charge. |
| 34 | Material & Labour for Repair and Rewinding of Electric induction motor 40 HP including disconnecting electrical connection carefully and shifting to workshop and opening the electric motor rotar & stater and Rewinding the motor as per existing gauge of copper winding wire, varnish, insulation sleve and reassembling the motor shift at site and connecting, testing on load ; complete all as specified and directed by Engineer-in-Charge. |
| 35 | Testing of treated water of STP from recognised lab for checking the parameters such as BOD TSS, PH & O&G, NO2, HCL, CO and other parameters as required all as specified and directed. Contractor has to submit report on due date at a frequency of one month. |
| 36 | Repair to air copmressor of 20 HP deffusers coarse bubble / nozzles including opening cafefully and cleaning / repair/ replacement rotary turn lobe air blower with air filter, silencer, gauger, safety valves, drive bearing and bearing (Gear side) oil seal drive end long shaft and Short shaft, Piston and sleeves, Leap seal gear and bearing cover, gasket gear cover and welding grinding & polishing drive rotor shaft assembly as per bearing size, replacement the recommended oil grade and greasing and assembling and testing on load. |
| 37 | Repair to air copmressor of 40 HP deffusers coarse bubble / nozzles including opening cafefully and cleaning / repair/ replacement rotary turn lobe air blower with air filter, silences, gauger, safety valves, drive bearing and bearing (Gear side) oil seal drive end long shaft and Short shaft, Piston and sleeves, Leap seal gear and bearing cover, gasket gear cover and welding grinding & polishing drive rotor shaft assembly as per bearing size, replacement the recommended oil grade and greasing and assembling and testing on load. |
| 38 | Supply and fix in replacement of MS pipe double flanged type not less than 4 mm thick heavy grade with all fittings laid in floor or fixed to wall and ceiling etc of sizes 100 mm dia complete all as specified and directed. |
| 39 | Supply only cast iron fittings for flanged or spigot socketed pipe such as tail piece connecting pieces bends tappers, tee pieces (Single or double branch) any type & angle/radious and straight connecting pieces suitable for bore upto 150 mm dia pipe complete all as specified and directed. |
| 40 | Supply and fix in replacement of CI butterfly valve heavy grade size 150 mm dia PN 1.6 complete all as specified and dircted. |
| 41 | Supply and fix in replacement of CI butterfly valve heavy grade size 100 mm dia PN 1.6 complete all as specified and dircted. |
| 42 | Supply and fix in replacement of CI butterfly valve heavy grade size 80 mm dia PN 1.6 complete all as specified and dircted. |
| 43 | Supply and mixing of poly electrolite (PE) Anionic 99 % complete all as specified and directed. |
| 44 | Supply and mixing poly Aluminium Chlorite (PAC) complete all as specified and directed. |
| 45 | Supply and chlorination of sodium hydrochloride solution having free chlorine from 7% to 10 % in and including 60 Ltr PVC Canes/ drum complete all as specified and directed. |
| 46 | Supply and fixing in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 1100 volts grade cross sectional area 35 sq. mm 3.5 core complete all as specified and directed. |
| 47 | Supply and fixing in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 1100 volts grade cross sectional area 70 sq. mm 3.5 core complete all as specified and directed. |
| 48 | Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 65 mm outer diameter and 55 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches,wall,floor,pole including bends, sockets and other connected accessories complete all as specified and directed by Engineer-in-Charge. |
| 49 | Supply and fix Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe For laying of Electric cable of size 90 mm outer diameter and 76 mm inner Diameter with IS 14930 (part 2):2001 laid in trenches,wall,floor,pole including bends, sockets and other connected accessories complete all as specified and directed by Engineer-in-Charge. |
| 50 | Supply and fix in replacement of submercible cable flat 4 Sqmm, 3 core copper cable, 1100 volts conforming IS 694:1990 complete all as specified and directed. |
| 51 | M & L for cleaning of sewage collection sump/ Treated water tank/ Tube settler tank of capacity 25000 Gallon : (i) Dewatering with submercible / sludge pump which empty the sump / tank upto base level. (ii) Removing sludge from sump wall and bottom sump have to be removed with the help of special sludge pump and remaining dirt which may have hidden in rough slots of the bottom to be removed mannualy with brush (iii) After cleaning the sump apply bleaching powder for disinfection of sump (Sewage collection sump). complete all as specified and directed. |
| 52 | All as per item S No.51.00 here in before but capacity 50000 Gallons. complete all as specified and directed. |
| 53 | Removal of dry sewage sludge from dry bed and and disposed off properly outside the MD land upto the entire satisfaction of engineer in charge complete all as specified and directed by the Engineer-in-Charge. |
| 54 | M and L in replacement of swith board including on /off push button fixed on ploycarbonate box as per site requirement all as specified and directed. |
| 55 | Starting up aerobic process from airation tanks (set of two), running of blower 24 hrs at a time basis add free cow dung water, DAP powder, urea powder add aerote the contents of the aerotion tank for 2 checking of MLSS level mainting up to prescribed level of PPCB complete all as specified and directed. |
| 56 | M & L for painting of sewage pipe line at STP 1.1 MLD, STP 2.5 MLD , STP 0.87 MLD & Lift wells complete all as specified and directed. |
| 57 | Excavation trenches not exc 1.5 m wide and not exc 1.5 mtr deep and getting out in any type of soil complete all as specified and directed . |
| 58 | Returning filling including spreading levelling, watering and well ramming in layers not exc 25 cm thick all as specified and directed. |
| 59 | Removal of surplus excavated soil to a distance not exc 50 M and and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed. |
| 60 | Supply and fixing in replacement of CI sluice valve heavy grade of size 150 mm dia PN 1.6 complete all as specified and directed. |
| 61 | Supply and fixing in replacement of CI sluice valve heavy grade of size 100 mm dia PN 1.6 complete all as specified and directed. |
| 62 | S & F in replacement CI non return valve 150 mm bore heavy duty grade PN 1.6 complete all as specified and directed by Engr -in- Charge. |
| 63 | S & F in replacemnt CI non return valve 100 mm bore heavy duty grade PN 1.6 complete all as specified and directed by Engr-in- Charge. |
| 64 | Material and labour for plastic media MBBR (moving bed bio reactor) complete all as specified and directed by Engr -in-charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysAug 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender