Tender For Development Of Water Supply Scheme Tube Wells, Rising Mains, Ohts, Distribution System House Service Connections Including Allied Works With 2 Years Oandm At Sitarganj Town.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
22 Sep 2026
43 days left
EMD
1.40 Crore
Bank guarantee accepted
Document Fee
29500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
sitarganj → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Development Of Water Supply Scheme Tube Wells, Rising Mains, Ohts, Distribution System House Service Connections Including Allied Works With 2 Years Oandm At Sitarganj Town.
BOQ
| Sl. No. | Item Description |
| 1 | Schedule No-1 Design & Documentation Work |
| 2 | Topographical Survey, Geotechnical investigation, Design, Drawing & Documentation work for Water supply and other ancillary works: Work Shall Include Design, Engineering, Preparation of Good for Construction drawing for civil, structural, mechanical electrical & instrumentation and vetting of major RCC structures from reputed Govt. institute (IIT/NIT or approved by Employer's Representative) Pipe line route survey ,Proposed & Existing Components Plot Survey,Household survey (Door to Door Survey), geo-tagging, Trial pits etc. as per Technical specification and as directed by Employer's Representative . |
| 3 | Schedule No-2 Water Supply and ancillary works |
| 4 | Excavation in ordinary soil (loam, clay, sand) for pipe line trenches including lift up to 1.5 m and all leads with back filling in layers not exceeding 20 cm including consolidation, watering, ramming of excavated earth in the trenches. |
| 5 | Excavation in soil mixed with single bouldres etc. requireing the use of special T&P, if any, for pipe line trenches including lift up to 1.5 m and all leads with back filling, watering, ramming of excavated earth in the trenches. |
| 6 | Filling of earth in trenches or in embankment by available earth in the layers not exceeding 20 cm in thickness with consolidation of each layer by ramming with mechanical compector under optimum moisture content (OMC) to give atleast 95% of maximum dry density (proctor density). Boulders or broken rock pieces are not allowed in filling of earth. (other than item No. 4 and 5). |
| 7 | Excavating, supplying, transporting of local earth (including royalty) by mechanical transport including all lead & lift ,loading & unloading at site etc. complete as per the direction of Employer's Representative. |
| 8 | Dewatering of water caused due to seepage of ground water and surface water, including rain etc. excluding excavation of foundation but during execution of civil works including supply of all machine operator, khalashi, POL, T&P, accessories required for proper completion of the work including disposal to the nearest drainage or as as directed by Employers Representative. |
| 9 | Providing and fixing Barricading at site of work for restricting the general public using 40 mm dia M.S. pipe (\\"B\\" class) as vertical post with average spacing of 1.80 meter between two vertical posts, having height at least 1.5 m above road/ ground level and at least 30-45 cm below road/ ground level by making suitable size hole in road/ ground, providing and fixing suitably two rows of 100 mm wide PVC Tape preferabley of red colour. The M.S. pipe shall be painted in red and white colour strips as per approved pattern as and when it becomes shabby but at least after every alternate shifting at new location. After shifting/ removal of barricading the hole shall be filled up properly and site is to be cleared in all respect. (Note: measurement is to be done in linear basis). |
| 10 | Providing and fixing Barricading at site of work for restricting the general public using 40 mm dia M.S. pipe (\\"B\\" class) as vertical post with average spacing of 1.80 meter between two vertical posts, having height at least 1.5 m above road/ ground level and at least 30-45 cm below road/ ground level by making suitable size hole in road/ ground, providing and fixing two rows of 40 mm dia M.S. pipe (\\"B\\" class) as horizontal members with nuts & bolts. Both vertical and horizontal members shall be painted in red and white colour strips as per approved pattern as when it becomes shabby but at least after every alternate shifting at new location. After shifting/ removal of barricading holes shall be filled up properly and site is to be cleared in all respect. (Note: measurement is to be done in linear basis). |
| 11 | Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6 mm angle iron or 50x50x3 mm hollow MS tube posts/horizontal members/ bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50 cm long MS angle 40x40x6 mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250 mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Employer's Representative which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Employer's Representative. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Employer's Representative.(Note : One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work). |
| 12 | Providing and laying sand bedding and encasing all around the pipeline in trenches including watering, ramming, consolidating and dressing complete as per technical specification & as directed by Employer's Representative. |
| 13 | Providing & laying Granular bedding with graded hard crusher broken stone of 100% passing through 20 mm sheive, 20 to 50 % passing through 10 mm sheive and 100 % retain on 6.3 mm sheive, laying in layers of thickness 10/15 cm including ramming, consolidation etc complete for all type of pipes of following sizes as per drawing and or as directed by Employer's Representative |
| 14 | Providing, Lowering into trenches with true to alignment, Laying & Jointing of full lenghts of HDPE Pipes of specified grade as per IS:4984-1995 and specifications, with testing of pipe line including supply of jointing materials. PE-100 PN-6 with testing of pipe line,disinfection, commissioning all complete as per technical specification & as per the direction of Employers Representative. |
| 15 | 110 mm dia |
| 16 | 140 mm dia |
| 17 | 160 mm dia |
| 18 | 200 mm dia |
| 19 | Providing of all materials, Carting from site store to site of work, lowering into trenches with true to alignment, Laying & Jointing of full lenght DI-K7 S&S Centrifugally Cast (Spun) Ductile Iron Pipes confirming to IS: 8329-2000 and part with cutting of pipe including supply of 'EPDM' rubber gaskets confirming to IS: 5382-1985, internal cement mortar lining for potable water with testing of pipe line,disinfection, commissioning all complete as per technical specification & as per the direction of Employers Representative. |
| 20 | 250 mm dia |
| 21 | 300 mm dia |
| 22 | 350 mm dia |
| 23 | Providing of all materials, Carting from site store to site of work, lowering into trenches with true to alignment, Laying & Jointing of full lenght DI-K9 S&S Centrifugally Cast (Spun) Ductile Iron Pipes and part with cutting of pipe confirming to IS: 8329-2000 including supply of 'EPDM' rubber gaskets confirming to IS: 5382-1985, internal cement mortar lining for potable water with testing of pipe line, disinfection, commissioning all complete as per technical specification & as per the direction of Employers Representative. |
| 24 | 150 mm dia |
| 25 | 200 mm dia |
| 26 | Providing of all materials, Carting from site store to site of work, Laying & Jointing of G.I D/F pipes (Heavy Duty) (including supply of all jointing materials) in trenches with its cutting and testing of pipe line etc complete as per the specification and as directed by Employers Representative. |
| 27 | 50 mm dia |
| 28 | Providing and Jointing D.I. specials of class K-12 suitable for push-on jointing as per IS: 9523-2000 including jointing material all complete as per specification, design, drawing and as directed by Employers Representative. |
| 29 | Upto 600 mm dia |
| 30 | Providing and Jointing of D.I. Specials of class K-12 suitable for mechanical jointing as per IS: 9523- 2000 including nut, bolt, gasket all complete as per specification, design, drawing and as directed by Employers Representative. |
| 31 | Upto 600 mm dia |
| 32 | Provide necessary T&P and cutting of following nominal dia of Cast Iron/Ductile iron (Spuns) pipes (Class 'LA' and 'A' for C.I. pipe and K-7 and K-9 for D.I. pipe) or specials including shaping and finishing the ends all complete as per specification, design, drawing and as directed by Employers Representative, for the following-(other than Item Nos.-15 and16) |
| 33 | 100 mm dia |
| 34 | 125 mm dia |
| 35 | 150 mm dia |
| 36 | 200 mm dia |
| 37 | 250 mm dia |
| 38 | 300 mm dia |
| 39 | 350 mm dia |
| 40 | 400 mm dia |
| 41 | Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice Valves of approved make & design standard of following dia complete (including jointing & jointing material) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Employer's Representative Class PN 1.6 (Manually Operated), for the following: |
| 42 | 100 mm dia |
| 43 | 150 mm dia |
| 44 | 200 mm dia |
| 45 | 250 mm dia |
| 46 | 350 mm dia |
| 47 | Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Scour valves of approved make & design standard of following dia complete including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Employer's Representative (Class (PN-1.6) Manually Operated), for the following- |
| 48 | 100 mm dia |
| 49 | 125 mm dia |
| 50 | 150 mm dia |
| 51 | 200 mm dia |
| 52 | 250 mm dia |
| 53 | 300 mm dia |
| 54 | 350 mm dia |
| 55 | Providing, lowering, laying, aligning, fixing in position and jointing in pipe line DI Kinetic Air Valves (PN1.6) as per IS 14845:2000 including isolation valve of following dia (including jointing and jointing material), including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Employer's Representative, for the following- |
| 56 | 50 mm dia |
| 57 | 80 mm dia |
| 58 | 100 mm dia |
| 59 | Providing, lowering, laying, aligning, fixing in position and jointing in pipe line Ductile Iron Non Return Valve Swing Type As per IS 14846 (PN 16) of following dia (including jointing and jointing material), including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Employer's Representative, for the following- |
| 60 | 50 mm dia |
| 61 | 80 mm dia |
| 62 | 100 mm dia |
| 63 | Supplying and fixing of Landing valve double outlet including stand pipe at suitable location and fixing the same in water supply lines including cost of valves, specials, labour and T&P complete in all respect as per the direction of Employers Representative. |
| 64 | 100 mm diameter Fire Hydrant Confirming to IS: 5290 (Flanged) |
| 65 | Providing, lowering, laying, aligning, fixing in position and jointing DI dismantling joint (suitable for sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning as per Technical Specifications and as per direction of Employers representative. |
| 66 | 80 mm dia PN-1.6 |
| 67 | 100 mm dia PN-1.6 |
| 68 | 150 mm dia PN-1.6 |
| 69 | 200 mm dia PN-1.6 |
| 70 | 250 mm dia PN-1.6 |
| 71 | Construction of brick masonry Sluice Valve Chamber for different size of valves with 7.5 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100 mm thick leveling course of PCC 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of steel reinforcement not less than 80 kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Employers representative. |
| 72 | For 100-150 mm dia pipe |
| 73 | For 200-250 mm dia pipe |
| 74 | For 300-350 mm dia pipe |
| 75 | Construction of brick masonry Air Valve Chamber for different size of valves with 7.5 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100 mm thick leveling course of PCC 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of steel reinforcement not less than 80 kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Employers representative. |
| 76 | Upto-150 mm dia pipe |
| 77 | For 200-250 mm dia pipe |
| 78 | For 300-350 mm dia pipe |
| 79 | For 400-450 mm dia pipe |
| 80 | Construction of brick masonry Scour Valve Chamber for different size of valves with 7.5 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand),both side 12 mm thick cement plaster in CM 1:4 (1 cement : 4 coarse sand), top cover slab 150mm thick RCC M25 grade including earthwork excavation, 100 mm thick leveling course of PCC 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) including cost of steel reinforcement not less than 80 kg per cum CC, form work, proper curing complete in all respect as per standard specifications and drawings and as directed by Employers representative. |
| 81 | Upto 150 mm dia pipe |
| 82 | For 200-250 mm dia pipe |
| 83 | For 300-350 mm dia pipe |
| 84 | Construction of RCC Electro-Magnetic Flow meter Chamber including earthwork excavation, 100 mm PCC (1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) as leveling course, RCC M25 grade for base slab, side wall & cover slab including cost of steel reinforcement not less than 80 kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Employers representative. |
| 85 | Upto 250 mm dia pipe |
| 86 | For 300-350 mm dia pipe |
| 87 | For 400-450 mm dia pipe |
| 88 | Constructing masonry Chamber 60x60x75 cm, inside in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants,and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design and as directed by Employers Representative. |
| 89 | Construction of Over Head Tank including, Geotechnical investigation, Detailed Structural Design (Water retaining structure shall be designed confirming to IS: 3370-2021, Construction of Flat Bottom/Intze Type RCC Over Head Tank with Maintenance Gallery (M-30 Grade concrete) supported on RCC Beam Column Structure of sufficient staging height, designed for Safe Bearing Capacity as per the soil investigation report. The cost shall be all inclusive of supply, erection, construction, all testing, disinfecting and commissioning of reservoir, maintenance gallery, Dog-legged / suitable stairs, MS ladders with cage (maintenance gallery to top of roof & stairs from last landing to maintenance gallery), Aluminium ladder (from manhole to inside the tank), manhole frame with cover, handrail (around roof, maintenance gallery, up to manhole & along stairs), water proofing treatment of tank (polymer modified slurry coating), painting all exterior concrete surfaces with weather shield emulsion paint, providing piping arrangement with flanged D.I (K-9) pipes for inlet/s and outlet/s, scour and overflow, motorised DI sluice valves for inlet and OHT bypass, PRV and manual Sluice valve at bypass of outlet valve and manual sluice valve for scour, Float valve, sluice valve chambers, Flow meter chamber, plinth protection, surface drain, flooring below OHT, Grill Gate at start of stair, Landscaping, lightning arrestor with two earth pits etc. complete in all respect as per specifications, design, drawing & satisfaction of Employers Representative. |
| 90 | 750 KL |
| 91 | 800-900 KL |
| 92 | 800-900 KL |
| 93 | 1100-1200 KL |
| 94 | Additional rates for staging per meter height beyond 12 m height including cost of all material, labour,shuttering, scaffolding T&P complete for following capacity ( in kiloliters ) Over Head Tanks |
| 95 | 750 KL |
| 96 | 850 KL |
| 97 | 850 KL |
| 98 | 1150 KL |
| 99 | Construction of Control Room building (G+1) as per drawing and technical specification including civil, electrical, mechanical, instrumentation, plumbing, EPABX system, PA system, CCTV system etc. complete in all respect as directed by Employer's Representative. |
| 100 | Construction of SCADA cum Billing Room as per drawing and technical specification including civil, electrical, mechanical, instrumentation, plumbing etc.in all respect as directed by Employer's Representative. |
| 101 | Construction of Pump House & Dosing Room at Tubewell location as per drawing and technical specification including civil, electrical, mechanical, instrumentation, plumbing etc.in all respect as directed by Employer's Representative. |
| 102 | Construction of Septic tank (10 users) as per drawing and technical specification including all ancillary works in all respect as directed by Employer's Representative. |
| 103 | Construction of soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in all respect as directed by Employer's Representative. |
| 104 | Construction of Boundary wall as per drawing and technical specification including earth work, PCC work, RCC work, reinforcement, masonry work, plastering, painting, structural steel work, formwork, framework, etc.in all respect as directed by Employer's Representative. |
| 105 | Construction of Internal road as per drawing and technical specification including all ancillary works.in all respect as directed by Employer's Representative. |
| 106 | Construction of Entrance Gate with pillar including all ancillary works. in all respect as directed by Employer's Representative. |
| 107 | Construction of tube well of 300 mm dia with bore dia 550 mm for 180 meter depth including mobilization & setting up of boring machine, lowering, centering of tube well assembly, suppy & filling of pea gravel, MS casing pipe (Minimum 7.9 mm thick), SS screen pipe, tubewell development, yield tests, as per technical specification in all respect as directed by Employer's Representative. |
| 108 | Extra over for depth beyond 180 meter upto 250 meter depth including mobilization & setting up of boring machine, lowering, centering of tube well assembly, suppy & filling of pea gravel, MS casing pipe (Minimum 7.9 mm thick), SS screen pipe (Minimum 5.0 mm thick), tubewell development, yield tests, as per technical specificationin all respect as directed by Employer's Representative. |
| 109 | Extra over for depth beyond 250 meter depth including mobilization & setting up of boring machine, lowering, centering of tube well assembly, suppy & filling of pea gravel, MS casing pipe (Minimum 7.9 mm thick), SS screen pipe (Minimum 5.0 mm thick), tubewell development, yield tests, as per technical specification in all respect as directed by Employer's Representative. |
| 110 | Construction of Cable trench as per drawing & technical specification including earth work, PCC ,RCC , steel reinforcement, steel work. Etc in all respect as directed by Employer's Representative. |
| 111 | Providing House Service Connection(Single Service connection) from HDPE/ Ductile Iron/GI distribution main to water meter, including supply & fixing of brass ferrule confirming to IS: 2692, clamp saddle of non corrosive Engineering Plastic(Polyethylene) body moulded with Stainless Steel threaded metal insert for tapping outlet.The stirrup metal plate shall be duly embedded in the plastic body, except at the place of nut-bolt lugs.Threading size & dimensions shall confirm to IS :554. The design of the saddle body should be such that, the service connection outlet metal insert shall project out towards pipe side & align with hole drilled on the pipe to ensure positive locking against rocking or creeping on the pipe, as might be caused by vibration, pressure or excessive external loading. Saddle seal shall be of virgin rubber SBR Grade 30 / NBR (NSF 61 approved). It shall be of type pressure activated hydro-mechanical design. It shall be contoured gasket to provide a positive initial seal, which increases with increase in the line pressure.Gasket shall be gridded mat, with tapered ends, with the outlet section having ring contacting the saddle body multiple rings contacting the pipe, preferably with a stainless steel reinforcing ring insert moulded to prevent expansion under pressure. Stainless Steel Type 304, NC rolled threaded, Tightening torque for1/2\\"(M12) nut bolt: 14g.m and for 5/8\\"(M16) nut bolt:21-23kg.m. Drilling the DI pipeline shall be through the chain and rachet mechanism and the drill hole shall be perpendicular to the axis of the DI pipeline, including supplying & laying MDPE PE 80 PN16 blue pipe as per ISO 4427 upto the property limit of both sides of road including supplying & fixing PP compression fittings such as Metal Insert Female Thread Adaptor with SS304 material (2Nos), Double compression elbow with compression on both sides (4Nos) complying to ISO 14236-2000 and GI plug-in for closure of ends/GI pipe with union to joint with existing connection, SS Ball Valve, FVC. All Pipes & fittings shall be PN 1.6 rating including transportion, loading & unloading at site, all labours, tools, eqipments etc. complete work including connecting new house service pipeline to existing/new legal house connection after completing the distribution pipeline as per the drawing & as directed by Employer's Representative.(Road Cutting & Restoration shall be paid separately) |
| 112 | 15 mm Connection |
| 113 | 20 mm Connection |
| 114 | 25 mm Connection |
| 115 | Road Cutting, Restoration & miscellaneous works |
| 116 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish with all lead outside the periphery of the area cleared as per direction of Employer's Representative. |
| 117 | Dismantling of flexible pavements and disposal of dismantled materials with all lead, stacking serviceable and unserviceable materials separately as per Technical Specification and as per direction of Employer's Representative. |
| 118 | By Manual Means |
| 119 | By Mechanical Means |
| 120 | Dismantling of cement concrete by mechanical means using concrete cutter tools & equipments to pieces not exceeding 0.02 Cum in volume and stock piling at designated locations and disposal of dismantled materials with all leads and lifts, stacking serviceable and unserviceable materials separately as per direction of Employer's Representative. |
| 121 | Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material with all lead as per direction of Employer's Representative. |
| 122 | Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401.For Grading I Material as per drawing and as per direction of Employer's Representative. |
| 123 | Granular sub-base/base/surface course with local materials (Table 400.13)/ by mix in place method normal Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. |
| 124 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification Clause 405. as per drawing and as per direction of Employer's Representative. |
| 125 | By Manual Means |
| 126 | By Mechanical means |
| 127 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405.as per drawing and as per direction of Employer's Representative. |
| 128 | By Manual Means |
| 129 | By Mechanical means |
| 130 | Providing and applying tack coat with Bitumen emulsion (RS-1) using emulsion distributor at the rate of 0.20 to 0.25 kg per sqm on the prepared bituminous surface cleaned with Hydraulic broom as per Technical Specification Clause 503.as per drawing and as per direction of Employer's Representative. |
| 131 | Providing and applying primer coat with bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification Clause 502 as per drawing and as per direction of Employer's Representative. |
| 132 | Providing and laying bituminous macadam with hot mix plant using crushed aggregates of grading as per Table 500.4 premixed with bituminous binder, transported to site with all lead laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled to achieve the desired compaction as per Technical Specification Clause 504. (Bitumen VG-10 @ 3.3% of the weight of mix has been used for analysis purpose. The choice of bitumen will depend upon the prevailing site conditions and shall be in accordance with Clause 504 of MORD) as per drawing and as per direction of Employer's Representative. |
| 133 | Providing and laying Dense Bituminous Macadam with 100-120 TPH.Grading I - 37.5mm nominal size batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.25% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 507 complete in all respects as per drawing and as per direction of Employer's Representative. |
| 134 | Providing and laying Bituminous Concrete with 60-90 TPH batch type hot mix plant producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 509 complete in all respects,as per drawing and as per direction of Employer's Representative. |
| 135 | Providing and laying Semi Dense Bituminous Concrete with 100-120TPH batch type HMP producing an average output of 75 tonnes per hour using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5% of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 508 complete in all respects Grading I - 13mm using Bitumen VG - 10.as per drawing and as per direction of Employer's Representative. |
| 136 | Providing, laying and rolling of open-graded premix carpet of 25 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. as per drawing and as per direction of Employer's Representative.Mechanical Means Bitumen (VG-10) |
| 137 | Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A, Type B and Type C as per Technical Specification Clause 510 as per drawing and as per direction of Employer's Representative.By Mechanical Means,Type A Bitumen (VG-10) |
| 138 | Construction of Cement Concrete Pavement (Construction of un-reinforced, dowel jointed, plain cement concrete pavement over a prepared sub base with 43 grade cement @ 400 kg per cum, coarse and fine aggregate conforming to IS 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver, spread, compacted and finished in a continuous operation including provision of contraction, expansion, construction and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and grades as per drawing )-M-20 Grade |
| 139 | Construction of Un-reinforced, Cement concrete pavement, thickness as per design, over a prepeared sub base with 43 grade cement or any other type PCC Grade M-30, coarse and fine aggregates conforming to IS: 383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less then 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (Steel channel, laying and fixing of wedges, steel plates including levelling the formwork and laying and fixing of 125 micron thick polythene film, as per drawing), spreading the concrete with shovels,rakes, compacted using needle, and plate vibrators, finished in continuous operation and curing of concrete slabs for 14 days, using curing compound where specified and water finishing to lines and grade as per drawings and technical specifications, as per drawing and as per direction of Employer's Representative. |
| 140 | Providing and Laying of Interlocking Concrete Block (M-35) Pavements having thickness 80 mm as per drawings and Technical Specification Clause 1504,as per drawing and as per direction of Employer's Representative. |
| 141 | Providing and Laying of Interlocking Concrete Blcok (M-35) Pavements having thickness 60 mm as per drawing and Technical Specification Clause 1504,as per drawing and as per direction of Employer's Representative. |
| 142 | Laying serviceable cement concrete interlocking paver blocks of any design/shape/thickness laid in required line, level, curvature,colour and pattern over and including 50 mm thick compacted bed of coarse sand , filling the joints with fine sand etc. all complete as per drawing and as per direction of Employer's Representative. |
| 143 | Disposal of surplus dismantlled material obtained from road cutting by mehancical means including loading, unloading with all leads & lifts, to the dumping site with all lead as per drawing and as per direction of Employer's Representative. |
| 144 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport with all lead also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete with all lead as per drawing and as per direction of Employer's Representative. |
| 145 | Dismantling of Exsiting Overhead tank including disposal of dismantled material all complete as per the direction of Employers Representative. |
| 146 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 147 | M-15 Cement Concrete |
| 148 | M-10 Cement Concrete |
| 149 | Ambient Air Quality |
| 150 | Noise Quality |
| 151 | Ground water Testing |
| 152 | Surface water Testing |
| 153 | Electrical Works |
| 154 | Supply Installation Testing & Commissioning of wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel for electrical Works, made out of CRCA sheet . Other parameters required as per point (a) ,(b), (c), (d) below:-(a)Thickness of sheet shall not be less than 1.6 mm up to 600 mm length / width of any compartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required . Side walls and cable alley compartments having bolted type doors with / without detachable extension type structure.(b) panel shall be duly treated for derusting in 7 tank process with dephosphating and with powder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware, separate detachable gland plate M.S. base channel (min75mm) , hinged door with locking arrangement for equipment/switchgear.(c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 125 amp ) and by solid bus bar (>125 amp ).(d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator.Complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 155 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar for electrical Works, by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. Electrolytic grade Aluminium bus bar 6010 grade |
| 156 | Providing & Fixing of BIS approved Current Transformer as for electrical Works ,ISI marked as per IS 2705- 1992/ conforming to IEC 60044-1, with secondary terminal of CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as required Current transformer Resin Cast Wound Primary / Ring Type Tape Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. Complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 157 | C T Class 1, Ratio upto 150/5, Burden 10 VA |
| 158 | Providing & Fixing of IP 51 Multi function meter for electrical Works, ISI marked (IS 16444)/ Confirming to IEC 61557 & IEC 62052 with LCD/ LED 3/4 line display capable of measuring electrical parameters like V, I, F, PF, KW, Kva, Kvar, Kwh, Kvah, Kvarh display with 1A/5A CT input for LV/ HV network, with /without RS 485 communication port etc. complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 159 | Multifunction LCD meter with V,A,F,PF,KW,KVA, old energy memory, class 1 accuracy without RS485 port. |
| 160 | Providing & Fixing of push button actuators and integral contact block of dia. 22.5 mm including making connection etc. as required. Complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 161 | Luminous type Red , Yellow, Green, Amber |
| 162 | Providing & Fixing of ISO certified company made UL listed , IP 65 110/220 V, unibody LED Indicating lamp IEC 60947 , CSA 22.2 with integral circuit, IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min. 29 mm, contact material phospher bronze for Led, PCB contacts shall be of brass (tin plated), impulse dielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDC including connection etc. as required. Complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 163 | Red/yellow/Green/Amber colour |
| 164 | Blue Colour |
| 165 | Providing & Fixing of IP 51 ( upto 500) V range Volt meter on existing panel for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Meter shall give true RMS measurements, acc. CI 1.0 or better , with field programmable primary & sec. values PT(VT) primary upto 2000 KV. |
| 166 | Digital type |
| 167 | Providing & Fixing of CT operated direct reading type IP- 51 Ampere meter on existing panel for electrical Works, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. Ampere meter shall give true RMS measurement, Acc. Cl 1.0 or better , Measuring current range 50 mA to 6 A, with Field-programmable primary and secondary values CT primary up to 15000 A, Field-programmable high and low threshold values as required. & complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 168 | Digital type Confirming to IEC 62053-21, Below 500 A |
| 169 | Providing & Fixing of ISO certified company made CT linked selector switch of 10 A for Ampere meter (4 position ) using high grade engineering material to international standards with cam assembly insulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided, complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 170 | Incoming- Supply Installation Testing & Commissioning of IP 40 4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardant & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C for electrical works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanism, true contact position indicator, line load inter-changeability, designed for both vertical and horizontal mounting with out any adverse effect on electrical performance, suitable for operation up to 55 degree and derating up to 40 degree. With Thermal Magnetic release. Complete in all respect as per specification, design, drawing & as directed by Employer Representative.respect |
| 171 | Upto 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 %Icu |
| 172 | 160 Amp , 35 kA, adjustable O/L & fixed S/C setting, Ics = 100 %Icu |
| 173 | Outgoing- Supply Installation Testing & Commissioning of IP 40 3 pole current limiting Moulded case circuit setting for electrical works, conforming to IS/IEC 60947 P -2 :2003 with front face and centralised adjustable, trip free mechanism, true contact position indicator, line load inter-changeability, designed for both vertical and horizontal mounting with out any adverse effect on electrical performance, suitable for operation up to 55 degree and without B587 derating up to 40 degree, pollution free degree 3 having positive isolation capacity, push (test) to trip, trip time less than 10 ms under s/c condition.With Thermal Magnetic release. Complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 174 | Upto 100 Amp , 25 kA, adjustable O/L & fixed S/C setting, Ics = 100 %Icu |
| 175 | Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanism , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 up to 32 A rating and 10,000 up to 63 A, 5000 for 80 A rating including making connections, testing etc. as required. complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 176 | 4P, 6-32 A |
| 177 | Supply, installation, testing & commissioning of Star Delta Starter in the existing panel with following rating. 18.5 KW |
| 178 | Supply, installation, testing & commissioning of Variable Frequency Drives with panel supplied by manufacturer conforming to applicable standards with logic inputs & outputs, relay outputs and analogue outputs, plug in I/O connections, display of electrical parameters, state of load & operating time, RS 485 serial link for connections to Modbus. & complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 179 | 37 KW |
| 180 | 45 KW |
| 181 | Supply Installation Testing & Commissioning of chemical Gel earthing system of Dual Pipe Technology made of with \\"B\\" Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c), (d), (e) below :-(a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second .(b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL accredited lab for low resistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per reference of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendments(c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.(d) Testing of earth resistance for value of 5 ohms or less.(e) Self certificate for confirming above standards from OEM is mandatory. With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell Complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 182 | GI pipe 3000 mm long, 50 / 25mm, Terminal 40mm x 6 mm GI Strip |
| 183 | Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. Complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 184 | 50mm x 6mm copper strip |
| 185 | 50mm x 6mm G.I. ( Hot Dipped ) Strip |
| 186 | 25mm x 6mm G.I. ( Hot Dipped ) Strip |
| 187 | Supply Installation Testing & Commissioning of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star level- 2 & BIS approved as per IS 2026- 1977 & losses as defined as per IS 1180 part I 2014. including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C up to 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect .NABL accredeated / CPRI/ ERDA lab testing reports with OEM certificate must submitted to engineer in charge .Transformer must be tested from CTL test lab of discom (if reqd.) before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, CTL testing charges & Inspection charges shall be reimbursed by the department to the contractor as per actual expenditure. All as per pre approved by Engineer in charge. No Load Voltage ratio : 11/0.433 KV, No. of phases / frequency : 3 Phases/ 50 Hz |
| 188 | 40 KVA |
| 189 | 63 KVA |
| 190 | 100 KVA |
| 191 | Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications A, B, C, D, E. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR .A) Double pole structure on 2 no ISMB ( I beam ) of size 150 x 75 mm, 10 mtr length using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required.B) Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,GI pipe of suitable length for operation.C) 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulatorsD) 3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv Overhead line with rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required.E) 3 no 11kv ACSR conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’. Complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 192 | Supply , Installation, Testing and Commissioning of Silent DG Set (As per latest CPCB emission norms) having specifications as per A, B, C, D, E, F,G,HA. 1500 RPM Diesel Engine conform to BS:649/5514 of suitable BHP Engine shall have residential silencer (isolated from main DG chamber), up to 3 M exhaust piping (with insulation & cladding ) as required .B. AC Brush less SPDP Alternator conform to BS 5000 (part 99) or IS 4722.-2001 . Alternator shall be self regulated with standard Alternator Protection( Over voltage , over speed & under voltage, under speed warning & shutdown).Engine & Alternator mounted on a common base Frame & coupled through a flexible coupling or close coupled.C. Standard canopy with Weatherproof, powder coated Accoustic enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet & filled with glass wool (96Kg/m3)/ Foam. as per IS 8183 the doors of 28/40/50/85 mm thick as per rating and fabricated from 1.6mm CRCA sheet packed with accoustic material,All doors/opening are sealed with neoprene/EPDN gaskets. The enclosure has built in fuel tank, with protection and tripping of DG set against temperature of more than 50 degree centigradeD. Electronic / Mechanical governor, Manual & electric Start ,Batteries with battery charger, Engine instruments panel,AVM pads All controls for operation of DG set are from outside the enclosure with DG control panel having Microprocessor based Genset monitoring & control system, MCCB/ACB of suitable rating, Ammeter, Voltmeter, PF meter, frequency meter, KWH meter,digital fuel display meter, Ind.lamps etc. mounted inside enclosure , visible and accessible from outside. The enclosure should be suitable for following capacity DG sets and alternator. Noise level shall be less than 75 dB at a distance of 1 Mtrs. duly certified by authorised agency etc. complete in all respect of following capacity :E. (A) Accoustic glass wool wall thickness should not be less then 40mm and not less then 20mm PU foam upto rating 100 KVA.(B).Accoustic glass wool wall thickness should not be less then 65mm and not less then 50mm PU foam upto rating 250 KVA.(C)Accoustic glass wool wall thickness should not be less then 100mm for rating above 250 KVA.F. First filling of the fuel tank shall be done by contractor and the prevailing fuel cost at that time shall be reimbursed to the contactor by department.G. Servicing of the DG set (as per OEM guidelines) during the DLP period shall be done by contractor including all consumables,actual charges shall be reimbursed to the contractor by department/client complete in all respect.H. OEM Must have BIS certificate and & shall have submit NABL / CPRI / ERDA/ CPCB standards approved lab type test reports before execution as required complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 193 | 62.5 KVA at 0.8 pf 415V 50Hz 3-ǿ |
| 194 | 82.5 KVA at 0.8 pf 415V 50Hz 3-ǿ |
| 195 | 100 KVA at 0.8 pf 415V 50Hz 3-ǿ |
| 196 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810. . Complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 197 | 4 C, 16 Sqmm |
| 198 | 3.5 C, 50 Sqmm |
| 199 | 3.5 C, 70 Sqmm |
| 200 | 3.5C, 120 Sqmm |
| 201 | Supplying and Laying ISI marked P.V.C. insulated submersible cable as per specification for electrical Works confirming toIS:694 and as per IS 8130 : 2013 of 1.1 kV grade .Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A or C ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4 including making connection etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. All as per pre approved by Engineer in charge, making connections. Complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 202 | 10.0 Sq.mm 3 core flat |
| 203 | 25.0 Sq.mm 3 core flat |
| 204 | Wiring for light point/fan point/exhust fan point/call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, sutaible size M.S. box and earthing the point with 1.5 sqmm FRLS PVC insulated copper condutor single core cable etc. as required all as per pre approved by Employer Representative, making connections, testing etc. complete as required. Complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 205 | Group A |
| 206 | Suppling & fixing of following sizes medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of reccessed conduit as required; 25 mm Complete in all respect as per specification, design, drawing & as directed by Employer Representative.MMS ( IS:9537 P - III ) PVC conduit, 25 mm |
| 207 | Supplying & Fixing metal box of 180 mm X 100 mm X 60 mm Deep (Nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc as required. |
| 208 | Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVS conduit as required |
| 209 | 4x2.5 Sq.mm. |
| 210 | Suppling & Fixing following way, single pole and neutral, sheet steel, MCB Distribution board, 240 V, on surface/ recess, complete with tinned Copper Bus Bar, neutral bus bar, din bar, interconnections, powder painted including earthing etc as required (But without MCB/RCCB/Isolater) |
| 211 | Supplying and fixing following rating, double pole, 240 V, isolater in exisitng MCB DB complete with connections, testing and commissioing etc as required; 63 A |
| 212 | Supplying & fixing 5A to 32 A rating, 240/415V, 10 kA, \\"C\\" curve, MCB suitable for inductive load of following poles in the exisiting MCB DB complete with connections, testing & Commissioning etc as required: Single Pole |
| 213 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made from polycarbonate /extruded aluminium powder coated housing with in built driver , Power Consumption of 18W/20W ,system lumen efficacy ≥ 120 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,p.f.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report from OEM shall be submitted. All as per pre approved by engineer in charge . foe additional technical parameters of product/ work, refer Annexure \\"A\\" attacheded with this BSR.4' LED Tube shape fixture 18/20 W (Extruded Al Base) |
| 214 | Providing & Fixing of energy efficient direct fit (Retrofit) Polycarbonate /Extruded Al Base Housing & diffuser SMD Mid Power LED tube (with integral driver), on existing fixture. Power Consumption of 18W / 20W system lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV ,THD < 15% ,p.f.≥0.95,CRI >80 , life time of minimum 35000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / Report fromOEM shall be submitted. All as per pre approved by Employers Representative4', 18/ 20 Watt LED Tube Without Batten (Extruded Al Base) |
| 215 | Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <1000mA shown in LM79 report. The luminaire shall be BIS certified and T.C. certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened ,color Rendering Index >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Employer Repersentative. |
| 216 | Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629; 3 Mtr |
| 217 | Supply & Fixing of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate battery with BIS approved make .luminaire should be secondary optic lenses for better distribution with delivered efficacy of > 100 Lumen perwatt.Bidder shall have in house R&D Laboratory which is recognised by ministry of Science & Technology department, Govt. OfIndia/ NABL.Bidder shall have inhouse pole & luminaire manufacturing facility.Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approved Lab. Guarantee for total system is two years .Note: All the above should be integrated and should be 1 system. make: Bajaj/Philips / Crompton.Compact Solar LED Street Light - 20W(MONO) 18V/ 12.8V9Ah/12W |
| 218 | Providing & Fixing of Heavy duty capacitor start, copper woind Double ball bearing 900/1400 RPM single phase Exhaust fan as per Relavent IS specification for electrical Works, conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. Complete in all respect as per specification, design, drawing & as directed by Employer Representative. |
| 219 | Mechanical Works |
| 220 | Submersible pump Supply,Installaion, Testing & Commissioning of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V +- 10%, 3 Ph, 50 Hz A.C. supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling with suitable suction strainer. Pump should have suitable dischargeout let as per manufactureres design. Antithrust stream lined non return valve shall be provided with the pump. 3m submersible copper conductor cable in single/ double run and 2 pairs of suitable size errection clamp 10 mm thick shall be provided with each pump.( with bronze / stainless steel(CF8M) impeller) ,all complete as per Technical Specifications , Drawing & as directed by employer's Representative. |
| 221 | PROPOSED TW-1 AT Near Prayas Hospital (Ward-6) (OHT Campus) (New) ,PUMP CAPACITY 1200 LPM , HEAD 90 M |
| 222 | EXISTING TW-2 (Replacement)At Opposite to Idgah ,PUMP CAPACITY 1500 LPM , HEAD 90 M |
| 223 | PROPOSED TW-3 TW_Sugar Cane Society (OHT Campus) (New) ,PUMP CAPACITY 1200 LPM , HEAD 90 M |
| 224 | PROPOSED TW-4 AT TW near Mazar (Ward-6) (New) ,PUMP CAPACITY 1200 LPM , HEAD 90 M |
| 225 | EXISTING TW-5 (Replacement) At Sidcul Bypass near Nakuliya ,PUMP CAPACITY 1200 LPM , HEAD 90 M |
| 226 | EXISTING TW-6 (Replacement) at Opposite to Kabristan ,PUMP CAPACITY 600 LPM , HEAD 90 M |
| 227 | Store Standby PUMP CAPACITY 600 LPM , HEAD 90 M |
| 228 | PROPOSED TW-7 AT Supriya Colony_Ward 10 (New) ,PUMP CAPACITY 1200 LPM , HEAD 90 M |
| 229 | Store Standby PUMP CAPACITY 1200 LPM , HEAD 90 M |
| 230 | Submersible pump Supply,Installaion, Testing & Commissioning of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V +- 10%, 3 Ph, 50 Hz A.C. supply, with cable guard, thrust carbon/fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling with suitable suction strainer. Pump should have suitable dischargeout let as per manufactureres design. Antithrust stream lined non return valve shall be provided with the pump. 3m submersible copper conductor cable in single/ double run and 2 pairs of suitable size errection clamp 10 mm thick shall be provided with each pump.( with bronze / stainless steel(CF8M) impeller) ,all complete as per Technical Specifications , Drawing & as directed by employer's Representative. |
| 231 | PROPOSED TW-8 AT Near Gurudwara, Pandari TW (Ward-13) (New) ,PUMP CAPACITY 1200 LPM , HEAD 90 M |
| 232 | Store Standby PUMP CAPACITY 1200 LPM , HEAD 90 M |
| 233 | Supply, installation, testing and commissioning of Mono Rail Chain Pulley Block suitable for lift up to 9m with chain 9m pulley block for Tubewells excluding cost of girder all complete as per Technical Specifications , Drawing & as directed by employer's Representative.Capacity - 2 Ton For Tube Wells |
| 234 | Supply, installation, testing and commissioning of glycerin filled Pressure gauge/Compound gauge of following ranges with isolation valve and tap off pipe ,all complete as per Technical Specifications , Drawing & as directed by employer's Representative.0-15 Kg/Cm2 |
| 235 | Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning , as per Technical Specification, Drawing & as directed by employer's Representative. Electrically Operated & SCADA Compatible class PN 1.6 |
| 236 | 150mm |
| 237 | 200mm |
| 238 | Providing, lowering, aligning, fixing in position in pipe line, DI D/Fresilient seated (soft seated) Swing check type Non Return Valve of approved make of following Pressure rating & dia complete, generally confirming to IS: 5312 (part -1)/ 2004 (amended up to date) and of following specifications: Body, Bonnet & disc of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG- 400/12 as per IS 1865 or Equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Face to face dimensions as per IS 5312 (part -1):2004 Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body, cover and disc inside and outside . Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410, Hinge SS AISI 316/410 ,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR \\"O \\"ring seal Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitable support structure as per directions of Employers Representative including jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification , Drawing & as directed by employer's Representative.NRV PN 1.6 |
| 239 | 150mm |
| 240 | 200mm |
| 241 | Fabrication, supply of flanged/ screwed ended MS pipe made from MS sheet strips of relevant IS specification of approved thickness by welding, lowering, laying, aligning, fixing in position at all level/depths in tubewells complete including all material, labour, testing and commissioning along with pipe as per Technical Specifications, Drawing & as directed by employer's Representative (with minimum 5mm thickness). |
| 242 | Colomn pipe (Flanged/Screwed) |
| 243 | 90 Degree Bend |
| 244 | AF Tee |
| 245 | DF Pipe |
| 246 | Providing, installation, testing and commissioning of Electromagnetic Flow Meter etc. including all materials and making connection with existing pipeline required for Electromagnetic Flow Meter including cutting the existing pipe line etc. complete in all respect as per technical specification , Drawing & as directed by employer's Representative. |
| 247 | 150mm |
| 248 | 200mm |
| 249 | Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Sluice valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per directionof Engineer. Electrically Operated & SCADA Compatible class PN 1.6OHT Inlet |
| 250 | 150mm |
| 251 | 200mm |
| 252 | SCADA & INSTRUMENTATION WORKS |
| 253 | Control room for remote communication with all iRTU Panel, Field Instruments of all DMA areas of entire package with Centralised SCADA Control Room for controlling all proposed/exsiting system of Tube well, OHT's & DMA for all locations for entire Water Supply Scheme.Design, manufacture, supply, installation, testing and commissioning of indoor type PLC panel, fabricated out of approx.min. 2 mm thick CRCA sheet Steel complete with latest configuration PC, necessary programming and SCADA software and comprising of all accessories Not limited to the following. CENTRALISED REDUNDANT PROCESSOR For all iRTU Station GIS based Communication, all field Instrument. Not limited to the following |
| 254 | FOR DI CHANNEL-Card with 16 channel & with base channelsFOR DO CHANNEL-Card with 16 channel & with base channelRELAY CARD - with 8 channelsAI CHANNEL - card with 8 channels & with base channelsAO CHANNEL- card with 4 channels & with base channelsSCADA Software & Centralised Cloud Based System, Data Acquisition & Remote Monitoring etc.Programming SoftwareCommunication Card With CableSystem Cabinet/ Panel 24V Dc Power Supply Redundant Remote I/O PanelServerMarshalling Panel Hardware Switchgear Lot Computer-32\\"LED –Engg. Stn.1No .& Operating Stn-1 Nos.. Total -2 Nos.Common Desktop for Centralised SCADA CentreLazer Printer-A4- ColourPrinterAux. Contactor-LotFurnitureAir Conditioner-1.5 TUPS-Redundant 2Kva, 150 AH*2 Battery Unit, Backup For 3 Hours BackupRemote Data Transfer GSM/GPRS Modem -Wireless At Sending / Receiving End Fibre Optic Cable Remote I/O Panel-LotConverter For Foc |
| 255 | iRTU PANEL WITH HMI AT TubewellsDesign, manufacture, supply, installation, testing & commissioning of PLC panel with 10” HMI , fabricated out of approx. min. 2 mm thick CRCA sheet complete with , necessary programming and HMI software and comprising of all accessories not limited to the following Not limited to the following |
| 256 | REDUNDANT PROCESSOR with 48nos. I/O capacity with 10” HMI FOR DI CHANNEL-Card with 16 channel & with base channelsFOR DO CHANNEL-Card with 16 channel & with base channelRELAY CARD - with 8 channelsAI CHANNEL - card with 8 channels & with base channelsAO CHANNEL- card with 4 channels & with base channelsHMI with Programming SoftwareCommunication Card With CableSystem Cabinet/ Panel Power Supply Redundant Hardware & Software Development –Lot Remote Data Transfer GSM/GPRS Modem -Wireless At Sending / Receiving End With Dual Sim UPS- 2 Kva with 150 AH*2 Battery Unit, Backup For 3 Hours for all RTU Panel Location |
| 257 | iRTU PANEL WITHOUT HMI AT FIELD LOCATIONDesign, manufacture, supply, installation, testing & commissioning of PLC panel without 10” HMI, fabricated out of approx. min. 2 mm thick CRCA sheet complete with , necessary programming and HMI software and comprising of all accessories not limited to the following Not limited to the following |
| 258 | REDUNDANT PROCESSOR with 48nos. I/O capacity with 10” HMI FOR DI CHANNEL-Card with 16 channel & with base channelsFOR DO CHANNEL-Card with 16 channel & with base channelRELAY CARD - with 8 channelsAI CHANNEL - card with 8 channels & with base channelsAO CHANNEL- card with 4 channels & with base channelsCommunication Card With CableSystem Cabinet/ Panel Power Supply Redundant Hardware & Software Development –Lot Remote Data Transfer GSM/GPRS Modem -Wireless At Sending / Receiving End With Dual Sim UPS- 2 Kva with 150 AH*2 Battery Unit, Backup For 3 Hours for all RTU Panel Location |
| 259 | Billing Centre Accessories accessories not limited to the following |
| 260 | Common Desktop for Billing Centre Centre |
| 261 | Printer |
| 262 | Furniture Set [Workstation Table, chair, Almirah/Rak etc. |
| 263 | Online payment SWAP Machine & other accessories |
| 264 | ELECTROMEGNATIC FLOW TRANSMITTER AT DMA INLET LINE, OHT DISCHARGEDATA LOGER & COMMUNICABLE WITH RTU/SCADA INTEGRATED FLOW TRANSMITTERProviding, installation, testing and commissioning of Electromagnetic Flow Meter etc. including all materials (excluding CI/DI fittings) and making connection with existing pipeline required for Electromagnetic Flow Meter including cutting the existing pipe line etc. With 4-20mA Signal tarnsmission complete in all respect as per technical specification and as per direction of Employers Representative. (at Inlet of DMA, Outlet of OHT/GLSR) |
| 265 | DN250 mm |
| 266 | DN300 mm |
| 267 | DN350 mm |
| 268 | ELECTRICALLY OPERATED FLOW CONTROL VALVE FOR Inlet at SUB-DMA, DMA & OHT Outlet.Providing, lowering, laying, aligning, fixing in position in pipe line, Resilient Seated D/F DI Flow Control valves of approved make & design standard of following dia complete (including jointing & jointing material ) including all material, labour, testing and commissioning along with pipe line as per Technical Specification & as per direction of Engineer.ELECTRICALLY OPERATED ON OFF FLOW CONTROL VALVE WITH MANUAL OPERATING HANDEL; Electrically Operated & SCADA Compatible class PN 1.6 with Inching |
| 269 | DN100 mm |
| 270 | DN125 mm |
| 271 | DN250 mm |
| 272 | DN300 mm |
| 273 | DN350 mm |
| 274 | Providing, Installation, Testing And Commissioning Of multijet domestic mechanical water meter Class-B dry dial, temper proof confirming to IS: 779-1994 or ISO 4064-2005 IP68 in position including all material, laboor, T&P etc complete for following Water Line Sizes including meter box for protection complete with all lead and lift |
| 275 | 15mm Water Meter |
| 276 | 20 mm Water Meter |
| 277 | 25 mm Water Meter |
| 278 | Providing, Installation, Testing and Commissioning of Pressure Transmitter : Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA with HART / Diaphragm: SS316L / Process Connection: 1/2 \\"NPT (M) / Accuracy: 0.15% Protection: IP67 |
| 279 | Providing, Installation Testing And Commissioning Of Ultrasonic Level Transmitter: Principle : Time Of Flight /Sensor Moc: PP/ Process Connection:1 1/2 Inch / 2 Inch, NPT Threaded Type Power Supply: 24 V DC / Output: 4- 20 mA / Display:Integral Display For Programming And Display Reading / IP 68 |
| 280 | PROVIDING, INSTALLATION, TESTING AND COMMISSIONING OF pH METER WITH TRANSMITTER AND SENSOR MEASURING RANGE: 0-12,ACCURACY: 1%, RESOLUTION: OPERATING TEMPERATURE: 0- 50°C, installed in DMA |
| 281 | Chlorine Analyser : Transmitter : Range: 0.05 to 20 ppm, Power Supply 230 VAC, Input: 2 Digital Sensors - one for chlorine and second for pH, Output: 4-20mA HART, IP66/67 Protection / Tx protection cover required / Sensor Range 0-14 pH , able to transmit digital signal to transmitter, calibration data can be transferred to Transmitter , process temp: 65 deg cen/ Sensor range:0.05 to 20 mg/l. |
| 282 | Providing, Installation, Testing And Commissioning Of Turbidity Analyser For Water Application : Turbidity Measuring Range: 0 To 100 Ntu ; Accuracy:+/-2% Of Reading Or +/-0.02Ntu; With Inbuilt Transmitter With 4-20 Ma Output ,Relay Contacts & remote/GPRS Communication for Existing & Proposed WTP Location |
| 283 | Providing, Installation, Testing Andcommissioning Of TDS Analyser For Water Application : Tds Measuring Range: 0 To 500 Mg/L ; Accuracy:+/-2% Of Reading ; With Inbuilt Transmitter With 4-20 Ma Output , Relay Contacts & Modbus Communication |
| 284 | Providing, Installation Testing And Commissioning Of Automatic chlorine dosing system: Principle : Time Of Flight Electronic Dosing Pump with LCD display, 4-20 MA communication with Chlorine Analyser, enable with proportional dosing (1W&1S) unit : with Process Connection, Common discharge & NRV |
| 285 | Providing, Installation Testing And Commissioning Of Hydostatic Level Transmitter for continuous monitoring the ground water level in Tube well and will generate alarm in PLC when water level goes down and will also prevent the dry run condition.Output : 4~20mA, Accuracy:≤ ±0.1%, Housing material: Suitable for Process Fluid |
| 286 | Supply, Installation, testing and commissioning of chemical Gel earthing system of Dual Pipe Technology made of with \\"B\\" Class G I Pipe as per IS 1239 ( part-1):2004 of Medium duty of following sizes as per points mentioned (a), (b), [c), (d), (e) below :-(a) filled with anti corrosive conductive compounds with the permanent sealings at both the ends, CPRI/ ERDA tested with RMS capacity of minimum 35- 40 KA for withstanding 1 second .(b) To ensure the moisture content and electrical conductivity, 25 kg for 2000 mm & 50 Kgs for 3000mm of resistance lowering earth enhancement material shall be used as a backfill compound. The compound shall be tested form NABL accredited lab for low resistivity ( less than 0.12 Ohm - meter) & high conductivity in nature with carbon as a major content as per reference of IS 3043-1987,IEEE 80-2013 (clause 14.5d) , IEEE 837 & IER 1956 with latest amendments(c) Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm.(d) Testing of earth resistance for value of 5 ohms or less.(e) Self certificate for confirming above standards from OEM is mandatory. With Pipe in Pipe Technology (Outer pipe dia. / Inner pipe dia. ) Minimum 100 mm dia borewell. |
| 287 | GI pipe 3000 mm long, 50 / 25mm, Terminal 40mm x 6 mm GI Strip |
| 288 | Supply & Laying following size earth strip in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required. All as per pre approved by Engineer in charge. |
| 289 | 25mm x 6mm G.I. ( Hot Dipped ) Strip |
| 290 | Supply &Laying following size earth wire in horizontal or vertical running round/surface/recess including riveting, soldering, saddles, making connection with GI/Cut symble etc. as required |
| 291 | 6 SWG dia Copper wire |
| 292 | SProviding and laying Stranded/ Flexible Annealede Bare copper conductor ,XLPE/PVC insulated suitably laid up together overall polyster taped Al (Mylar tape wrapped) along with ATC Drain wire overall PVC sheathed (ST-1) overall screened Pair armoured instrumentation Cables generally confirming to PAS 5308- Part-2-.2009. |
| 293 | 1.5 Sq. mm, 2 core |
| 294 | Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. |
| 295 | 100mm x 50mm x 1.6mm |
| 296 | 150mm x 50mm x 1.6mm |
| 297 | 300mm x 50mm x 1.6mm Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedSep 22, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 43 daysSep 22, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 43 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender