Tender For Repair /Maintenance Of Lt Ug Cable, Panel Boards, Feeder Pillars , Junction Boxes & Allied Works At Domestic Area Af Station Jammu Under Ge Af Jammu
Tender Value
30 Lakhs
Estimated cost
Bid Submission
28 Aug 2026
4 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Jammu → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair /Maintenance Of Lt Ug Cable, Panel Boards, Feeder Pillars , Junction Boxes & Allied Works At Domestic Area Af Station Jammu Under Ge Af Jammu
BOQ
| Sl. No. | Item Description |
| 1 | M&L in replacement of out door aluminium busbar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts with porcelain insulator weather and vermin proof with IP 54 protection, made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer type ,both side openable, from front side & back having, locking arrangement on both sides,mounted over 50x50x6 mm angle iron stand at the bottom of height not less than 45 cm above ground level and not less than 30 cm in ground / floor mounted duly grouted in PCC 1:3:6 type C1 (using 20mm graded stone aggregate) factory made duly powder coated including taking out of old U/S busbar and MCCB 200Amp 25KA four pole x 01 Nos as a Incomer all as directed by Engr-In-Charge. |
| 2 | M&L in replacement of out door aluminium busbar chamber feeder box of cap 400 Amp , 3 phase, 4 wire, 415 Volts with porcelain insulator weather and vermin proof with IP 54 protection, made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer type ,both side openable, from front side & back having, locking arrangement on both sides,mounted over 50x50x6 mm angle iron stand at the bottom of height not less than 45 cm above ground level and not less than 30 cm in ground / floor mounted duly grouted in PCC 1:3:6 type C1 (using 20mm graded stone aggregate) factory made duly powder coated including taking out of old U/S busbar and MCCB 250Amp 25KA four pole x 01 Nos as a Incomer all as directed by Engr-In-Charge. |
| 3 | S&F any type and any capacity 25 watt of new street light/security light including making electric connection using two run of 1.5 sqmm single core unarmoured wire from junction box complete all as specified and directed by Engr-in-Charge. |
| 4 | Supplying, installing, testing & commissioning out door type cubical panel board outer shell made out of 3.15 mm thick MS sheet including door and inner shell made out of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front & back openable, double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :- |
| 5 | a) Aluminium bus bar 300 Amps cap 4 wire fixed on insulator not less than 1.0 mtr long bus bar -1 set(b) Incoming MCCB 200 Amps 4 pole 415 Volts AC with thermal magnetic 36 KA, Ics=100%, Icu class-2 front face isolation with positive break indication with double break contacts with spreader and phase barrier complete all as directed. - 1 Nos.Make - Schneider/Legrand/Siemens/ABB/HAGER(c) Outgoing MCCB 63 Amps 4 pole 415 Volts AC with thermal magnetic 25 KA, with double break contacts with spreader and phase barrier complete all as directed. -3 Nos(d) Outgoing MCB 32 Amps 4 pole 415 Volts AC with thermal complete all as directed. -2 Nos e) Digital Ammeter 0-500 A of size 96sqmm with selector switch-01 No.Make Schneider/Legrand/ABBf) Digital Volt meter 0-500 V of size 96sqmm with selector switch-01 No Make Schneider/Legrand/ABBg) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming includin back up protection by 2 Amp MCB RYB with holder-01 set of three. Make -Schneider/Legrand/ABBh) CT Coils of suitable ratio-01 Set. Make- AE |
| 6 | Supply laying & testing in replcement of cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty_) LT 1100 volt grade with stranded aluminium conductor of size 185 sqmm 3.5 core Complete all as specified and directed by the Engineer-in-Charge. . |
| 7 | All as per srl item No 05 here-in-before but of size 120 Sqmm 3.5 core. |
| 8 | All as per srl item No 05 here-in-before but of size 95 Sqmm 3.5 core. |
| 9 | All as per srl item No 05 here-in-before but of size 70 Sqmm 3.5 core. |
| 10 | All as per srl item No 05 here-in-before but of size 50 Sqmm 3.5 core. |
| 11 | All as per srl item No 05 here-in-before but of size 35 Sqmm 3.5 core. |
| 12 | All as per srl item No 05 here-in-before but size 25 sq mm, 3.5 core. |
| 13 | All as per srl item No 05 here-in-before but size 16 sq mm, 4 core. |
| 14 | All as per srl item No 05 here-in-before but size 10 sq mm, 4 core. |
| 15 | All as per srl item No 05 here-in-before but size 10 sq mm, 2 core. |
| 16 | Supply,laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. all as specified and directed by Engr in Charge of size 50mm outer dia and 38mm inner dia |
| 17 | Ditto all as per items No 15 but of size 77mm outer dia and 63mm inner dia Complete all as specified and directed by the Engineer-in-Charge. . |
| 18 | Ditto all as per items No 15 but of size 90mm outer dia and 76mm inner dia Complete all as specified and directed by the Engineer-in-Charge. . |
| 19 | Ditto all as per items No 15 but of size 145mm outer dia and 126mm inner dia Complete all as specified and directed by the Engineer-in-Charge. . |
| 20 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil for laying of LT UG cables Complete all as specified and directed by the Engineer-in-Charge. . Note:- The Rate quoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site |
| 21 | Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in hard dense soil |
| 22 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point |
| 23 | S&F any type and any capacity 120 watt of new LED floodlight including making electric connection using two run of 1.5 sqmm single core unarmoured wire from junction box complete all as specified and directed by Engr-in-Charge. |
| 24 | S&F Sub main wiring with two single core PVC insulated unshesthed cable copper conductor(FRLS-H) of size 2.5 sqmm multistranded and one run of 2.5 sqmm PVC insulated unsheathed copper conductor(FRLSH) as earth continuty conductor drawing in and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories concealed in wall, cutting of chases in walls, floors, ceilings, beams etc and making good the disturbed surfaces as directed including taking down old unservicable wiring complete all as specified and directed. (Two run of single core cable and one run of earthing cable and one run of PVC conduit shall be measured as one length.) |
| 25 | S&F in replacement of barrel type fuse capacity 50Amp working pressure 11000 volts as specified and directed by Engr-in charge. |
| 26 | S&F in replacement of barrel type fuse capacity 100Amp working pressure 11000 volts as specified and directed by Engr-in charge. Please Enable Macros to View BoQ information |
| 27 | S&F in replacement of barrel type fuse capacity 100Amp working pressure 11000 volts as specified and directed by Engr-in charge. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Aug 07, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysSep 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 11 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender