Defence Statutory Bodies & Commissions/Committees Closing in 18 days TDR #56904613

Tender For Provn Of Underground Static Water Tank At Jhallas

Issued by Statutory Bodies & Commissions/Committees · Poonch, Jammu and Kashmir
Tender Value
48.30 Lakhs
Estimated cost
Bid Submission
11 Sep 2026
18 days left
EMD
96600
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Poonch → Jammu and Kashmir
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provn Of Underground Static Water Tank At Jhallas

BOQ

Name of Work:- PROVN OF UNDERGROUND STATIC WATER TANK AT JHALLAS
Sl. No. Item Description
1Schedule 'A' Part-I (Building Work)
2Construction of RCC Static Water Tank of Capacity 50000 Gallons complete all as specified in Sch 'A' and shown on drg.
3Schedule 'A' Part-II (Road/ Path/ Culvert)
4Total amount of Sch 'A' Part-III (Road/ Path/ Culvert) brought forward from srl page No 22
5Schedule 'A' Part-III (External Water Supply)
6Total amount of Sch 'A' Part-III (External Water Supply Works) brought forward from srl page No 23
7Schedule 'A' Part-IV (External Electric Supply)
8Total amount of Sch 'A' Part-III (External Electric Supply Works) brought forward from srl page No 26
9Schedule 'A' Part-V (Misc Items of Works Pertains to External Electric Supply and Water Supply works )Note : This schedule is not prepriced by MES and the pre-priced rate indicated as \\"Rs0.00\\" under Col.5 signifies this fact only.
10Supplying, installing, testing and commissioning of AC 3 phase, 50 Hz, 100 KVA capacity transformer of latest approved level, step down, outdoor type, 11000/433 Volts (at no load) all as per IS 1180 (Part-1): 2014, copper wound, oil immersed, naturally cooled with external cooling tubes, ONAN cooling, core type, delta connected on primary (HV) side and star connected on secondary (LV) side in accordance with vector symbol DYN-11 with neutral brought out on secondary (LV) side and having tappings in equal steps of 2.5% from (+) 2.5% to (-) 5% on primary side by means of hand operated off load tap changing gear, so as to change/correct LT voltage on secondary side including provision of all necessary/standard fittings, all as per latest IEC 76 amendments and Energy Efficiency Level-2 Transformer as per IS 1180 (Part-1): 2014 complete as specified and as directed, comprising of the following accessories:(a) The core shall be stack/wound type of high grade Cold Rolled Grain Oriented steel (IS 3024) or Amorphous Core annealed steel lamination having low loss and good grain properties, coated with hot oil proof inter layer insulation of Nomex / Epoxy dotted Kraft Paper, bolted together and to the frames firmly to prevent vibration or noise. The core shall be stress relieved by annealing under inert atmosphere if required. The complete design of core must ensure no load/ core loss should be minimum with continuous working of the transformers. LV winding shall be such that neutral formation will be at top making it more connection convenient. (b) The maximum allowable losses at 75°C for 11/0.433 kV at 50% of rated load and total losses at 100% of rated load shall not exceed the maximum total loss of 475 Watts and 1650 Watts respectively without any positive tolerance, all as per specified in IS-1180 (Part-1): 2014. (c) The percentage impedance of transformer at 75°C for 250 KVA shall be 4.5 percentage as per Table 3 of IS-1180 (Part-1): 2014.(d) The rated Basic Insulation Level (BIL) shall be 75 KVp as per Table 2 of IS-1180 (Part-1): 2014.
115.01 (Contd..)(e) Transformer tank construction shall be conform para 15 of IS 1180 Part-1 : 2014.It can be with radiator fins or cooling tubes. The tank covers shall be bolted /clamped alternatively welded with tank rim so as to make leak proof joint. The tank shall be of adequate mechanical strength to withstand positive and negative pressure built up during Transformer operation and all weldings operations shall be carried out by qualified welders.(f) A suitable cable box on primary side HV consisting three Nos of HT porcelain bushings with brass/gun metal bushing rods conforming to IS 2099 and IS-3347. A suitable cable box on secondary side LV consisting four Nos of porcelain bushings with Gun metal bushing rods complete with nuts and washers conforming to IS 7421. The bushings shall be fixed with straight pockets and in the same plane or the top cover. The Minimum clearance in cable boxes shall be provided as per Para 11.1 of IS 1180 Part 1 : 2014.(g) The conservator must be provided with oil gauge, air release plug and breathing device shall be fixed to the conservstor, it also includes drain plug and a filling hole of 32 mm with cover. The capacity of a conservator tank shall be designed keeping in view the total quantity of oil and its contraction and expansion due to temperature variations.The silical gel crystal in beather to be filled for moisture absorption.(h) The painting of transformer shall be conform para 15.5 of IS 1180 Part 1 : 2014. Inside of the transformer shall be painted with varnish or oil resistant paint and outside shall be painted one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethene base paint. Please Enable Macros to View BoQ information
125.01 (Contd..)(e) Transformer tank construction shall be conform para 15 of IS 1180 Part-1 : 2014.It can be with radiator fins or cooling tubes. The tank covers shall be bolted /clamped alternatively welded with tank rim so as to make leak proof joint. The tank shall be of adequate mechanical strength to withstand positive and negative pressure built up during Transformer operation and all weldings operations shall be carried out by qualified welders.(f) A suitable cable box on primary side HV consisting three Nos of HT porcelain bushings with brass/gun metal bushing rods conforming to IS 2099 and IS-3347. A suitable cable box on secondary side LV consisting four Nos of porcelain bushings with Gun metal bushing rods complete with nuts and washers conforming to IS 7421. The bushings shall be fixed with straight pockets and in the same plane or the top cover. The Minimum clearance in cable boxes shall be provided as per Para 11.1 of IS 1180 Part 1 : 2014.(g) The conservator must be provided with oil gauge, air release plug and breathing device shall be fixed to the conservstor, it also includes drain plug and a filling hole of 32 mm with cover. The capacity of a conservator tank shall be designed keeping in view the total quantity of oil and its contraction and expansion due to temperature variations.The silical gel crystal in beather to be filled for moisture absorption.(h) The painting of transformer shall be conform para 15.5 of IS 1180 Part 1 : 2014. Inside of the transformer shall be painted with varnish or oil resistant paint and outside shall be painted one coat of thermo setting powder paint or one coat of epoxy primer followed by two coats of polyurethene base paint. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56904613
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 48.30 Lakhs
LAST DATE 11-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provn Of Underground Static Water Tank At Jhallas
Basic Detail
Tender No GE/PNH-60/2026-27
Bidding Type Tender
Location
City Poonch
State Jammu and Kashmir
Key Dates
Publish Date 07 Aug 2026
Submission Date 11 Sep 2026
Open Date 15 Sep 2026
Finance
Tender Value 48.30 Lakhs
Tender Fee 500
EMD 96600
Exemption Available
Document List
05b82e13-019b-446c-bdae-89c08caaacf4.html
BOQ_877715.xls
TENDER.pdf
Tendernotice_1 (7).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 07, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 11, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 18 days
Sep 15, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 22 days

Tender Documents

Download All (ZIP) ↓
html

05b82e13-019b-446c-bdae-89c08caaacf4.html

xls

BOQ_877715.xls

pdf

TENDER.pdf

pdf

Tendernotice_1 (7).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders