Tender For Repair/Replacement Of Aluminium Joineries, Plastering And Wall/ Floor Tiling Work Repairs In 1 Wec, Wee Wksp, Das, Eetsu, Tarag Mess, Galaxy Mess, Aec, 1 Wec Md Accn And Uri Enclave In The Area Of Age B/R-I Including Repair/Replacement Of
Tender Overview
Project Description
Tender for Repair/Replacement Of Aluminium Joineries, Plastering And Wall/ Floor Tiling Work Repairs In 1 Wec, Wee Wksp, Das, Eetsu, Tarag Mess, Galaxy Mess, Aec, 1 Wec Md Accn And Uri Enclave In The Area Of Age B/R-I Including Repair/Replacement Of Old Unsv Old Batten/Concealed Wiring To Concealed Copper Wiring, Led Fittings & Misc Works At 1 Army Hq Sig Regt, Army Cyber Gp, Old & New Aps Colony Under Ge (Central) Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Taking down chowkhat or frame not exceeding 1.5 Sqm each with shutter (without taking off shutter from the frame) |
| 2 | Taking down chowkats or frames(without taking off shutters from the frame) area exc 1.5 Sqm but n.exc 4.0 Sqm each. |
| 3 | M&L aluminium alloy powder coated windows including aluminium coated frames double pannel/silding track, bottom weighing not less than 1.015 Kg/Rm ,sides and top not less than 0.826 kg/Rm double revated and 0.55 kg/Rm for window shutter with one fixed glazed shutter and two nos glazed/gauged shutter silding type with aluminium sectins as per series-A (15mm) 3 track/double pannel of jindal section number for silding windows with framed shutter including aluminium allow powder coated snap type beads handles with locking arrngement spring action and glazing clips joint cleats rubber gaskets etc inclding provision of 4.5 mm thick tinted frosted glass of superior quality and stainless steel jail including all standard fittings complete all as specified and directed |
| 4 | S&F Anodised aluminium grill (anodised transparent or dyed to required shade according to IS :1868 with minimum anodiccoating of grade AC 15) of approved design/pattern, with approved stadandered section and fixed to existing window frame with CP brass/stainless steel screws @200mm c/c, incl cutting the grill to proper opening size for ficing and operation of handles and fixing approved anodised aluminium standard section around the opening all complete as per requirement and direction of Engineer-in-charge. |
| 5 | Anodised aluminium powder coated sliding windows, window shutters and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as locking system, suitable handle (1 no.) complete all as specified and as directed by Engineer-in- charge. |
| 6 | Providing and fixing factory made uPVC any colour pannel window of area n exc. 2.00 Sqm each made of extruded profiles with wall thickness of 2.3mm ( + 0.2mm). Window profile with hollow section with multi chamber, Frame (88mm x 52mm), pannel sash (42mm x 67mm), interlock (One vertical length in each shutters) (45.5mm x 28mm).Glazing bead (24.5mm x 16mm) will be mitred cut and fusion welded at all corners, including railing of holes for fixing hardware and drainage of water etc., making arrangement for fixing of hardware, EPDM gasket, 1.2 + 0.2mm thick galvanised steel frame (30mm x 18) 2 nos, sliding sash (30mm x 18mm), pannel mesh sash (26mm x 10mm) profile to be inserted in required profile, frame will be fixed to the wall with 8mm x 100mm long fasterners. Hardware (Touch lock of zinc alloyed (any colour powder coated), steel roller system, Stainless steel wire cloth 0.36mm nominal dia of wire and avg width of aperture 1.40mm and required accessories). Note: The unit rate quoted by contractor included cost of glass and includes all other connected accessories. Net opening will be measured for payment purpose. |
| 7 | M & L for applying two coats of oil bond destember over one coat of birla white wall care putty on newly/old plastered surfaces(internal) of walls complete all as specified and directed by Engineer-in-charge. |
| 8 | S&F solid PVC door frame of sixe 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube in opening as per specification and drawing. |
| 9 | S&F factory made soilid panel PVC Door shutter 30mm thick (Stype) consisting of frame made out MS frame shall be covered with heat moulded plain coloured PVC 'C' channel having PVC sheet stripof 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail, & bottom rail; Panneling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification and drawing. |
| 10 | S&F SS barrel tower bolt extruded section 150mm long and fixed with SS Screws (ISI Marked) |
| 11 | S&F 100mm extruded ALUMINIUM HANDLE handle fabricated type and fixed with Screws(ISI Marked) |
| 12 | S&F SS butt hinges medium weight 75mm size fixed with SS screws (ISI Marked) |
| 13 | Dismantling false ceiling boards/ wall pannel any description and in any position incl frame work. |
| 14 | S&F solid PVC wall lining consisting of 5mm thick plain colour pvc wall lining 2mm thick plain colour PVC sheet dully fitted into the wall inclusive of solvent cement and fixing at site on PVC frame of 5mm thick PVC Sheet fillet of widht 35mm for wall panelling as per specifications and drawing but single side prelaminated PVC sheet use instead of plain clour sheet |
| 15 | Taking down care fully copper/aluminium point wiring from caping/casing or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge. |
| 16 | Taking down old MCCB , TPN DBs , SPN DBs, & main switch/ enclosure box of any make and type from the site and making good surface complete all as specified and directed. |
| 17 | Taking down old submain wiring of any size, including coduit and make from the site complete all as specified. |
| 18 | Taking down old unsv light fitting of any size and make from the site and making good surface complete all as specified. |
| 19 | Material and labour for point wiring for one light point or one fan point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, PVC insulated & unsheathed cable, 1100 volts grade in and including concealed / surface PVC conduits as suitable of site (Medium grade) of size not less than 20 mm dia incl proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching all as directed with sunken type pressed steel terminal box and junction boxes of minimum thickness 1.2 mm size, 3 mm thick hylem sheet cover for terminal boxes painted with one coat of red oxide primer and two coats of black bituminous paint for mounting fittings and wiring to be terminated in pressed steel sunken boxes with and including all accessories for PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed. |
| 20 | All as per item No 19 above but one light/fan point controlled by one switch. |
| 21 | All as per item No 19 above but One 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board |
| 22 | All as per item No 19 above but One 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. |
| 23 | All as per item No 19 above but One bell point controlled by one bell push. |
| 24 | All as per item No 19 above but One light point controlled by two Nos two way switches |
| 25 | All as per item No.19 above but point wiring with two single core 4.0 sqmm size cables and one 4.0 sqmm green colour cable as earth continuity conductor for one 6 pin 15 Amps socket out let on independent board. |
| 26 | M&L switch piano flush type 5 Amp SP one way ISI marked complete all as specified. |
| 27 | M&L switch piano flush type 5 Amp SP two way. |
| 28 | M&L switch piano flush type 15 Amp SP one way ISI marked complete all as specified. |
| 29 | M&L bell push,flush type,5 amp ISI marked complete all as specified. |
| 30 | M&L socket outlet 5 pin 5 Amp flush type ISI marked complete all as specified. |
| 31 | M&L socket outlet 2 in 1,3 pin 5/15 Amps ISI marked complete all as specified. |
| 32 | M&L ceiling rose PVC polycorbonate,isolated body. complete all as specified. |
| 33 | S & F electronic fan regulator 5 step ISI marked connecting complete all as specified. |
| 34 | M&L bell electric (ding dong) 230 volt, SP all as specified and directed. |
| 35 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including in and including concealed / surface PVC conduits as suitable of site Medium grade of ISI Marked not less than 20 mm dia and all conduit accessories concealed in wall on surface in ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated modular metal flush box, concealed in walls with suitable modular inner and outer plate for housing switches, socket out let and fan regulators etc, complete all as specified. |
| 36 | All as per item No 29 above but one light /Ceiling fan/exhaust fan point controlled by one switch. |
| 37 | All as per item No 29 above but one bell point controlled by one bell push. |
| 38 | All as per item No 29 above but one 3 pin 5 Amps socket outlet point controlled by one No one way switch on independent board. |
| 39 | All as per item No 29 above but one 3 pin 5 Amps socket outlet point controlled by one No one way switch on same board |
| 40 | All as per item No 29 above but one light point controlled by two Nos two way switches |
| 41 | M&L point wiring with PVC unsheathed multi stranded copper conductor cable 4.0 sqmm FRLS 1100 Volts in and including concealed / surface PVC conduits as suitable of site (Medium grade) of ISI Marked not less than 20 mm dia in new M S steel terminal boxes modular including one run of using 4.0 sqmm FRLS 1100 Volts copper conductor cable as earth continuity connected to common earth for one 15 A switch socket power point, all as specified |
| 42 | M&L switch Modular type 6 Amps one way ISI marked 230V AC complete all as specified. |
| 43 | M&L Modular socket outlet 5 pin 6 Amp socket 2 module ISI marked complete all as specified. |
| 44 | M&L switch Modular type 16 Amps one way ISI marked 230V AC complete all as specified. |
| 45 | M&L Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified. |
| 46 | M&L switch bell push Modular type 6 Amps 1W-1 module, ISI marked 230V AC complete all as specified. |
| 47 | M&L switch modular type 6 amp SP two way ISI marked complete all as specified. |
| 48 | Supply & Fix Modular five stepped type electronic fan regulator 1 module ISI marked 230V AC complete all as specified. |
| 49 | M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 4 Sqmm in and including in and including concealed / surface PVC conduits as suitable of site (Medium grade) not less than 20 mm dia, proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 4.0 Sqmm size stranded conductor as earthwire.Note for item No 38 & 39 :- Three run of single Core wire and one run of conduit shall be measured and paid as one unit. |
| 50 | M&L for submain wiring with two single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 6 Sqmm in and including concealed / surface PVC conduits as suitable of site (Medium grade) of not less than 20 mm dia, proper colour coding Phase -red/yellow/blue, neutral- black and earth green including making good disturbed surfaces with existing colour coding matching for submain wiring and connection complete FRLS 1100 volts unsheathed stranded copper conuctor cable of 6.0 Sqmm size stranded conductor as earthwire. |
| 51 | M&L for submain wiring with four run of single core PVC insulated FRLS 1100 Volts unseathed stranded copper conductor cable 10 Sqmm in and including concealed / surface PVC conduits as suitable of site (Medium grade) of not less than 20 mm dia, for submain wiring and connection complete FRLS 1100 volts unsheathed one run of stranded copper conductor cable of 10 Sqmm size stranded conductor as earthwire. Note:- Four run of main wire PVC insulated FRLS 1100 volts unsheathed stranded copper conductor and one run of earth wire with one run of PVC conduit will be measured and paid in one length. |
| 52 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed. |
| 53 | Supply and fix LED batten luminaire surface mounted, 2 feet system wattage of 10 Watts, including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed. |
| 54 | Supply and fix 10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP-65 Protection, System level efficacy of the Luminary is > 100 lumen/watts, Power Factor > 0.90, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-5700K, Surge protection of 2.0 KV, including connecting up with necessary PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed complete Make : CG/Havells/Philips/Orient |
| 55 | S& F in replacement recessed mounting LED FLAT panel 2'x2' made of crca sheet steel duly power coated with high efficient LED and glaire free full opal diffuser , IP 20, System level efficacy of the Luminary is > 100 lumen/watts, Power Factor > 0.90, driver with Voltage range 150-270V, Suitable for 36 watt,230 volts ,50 Hz AC Supply, Neutral White,with electronic driver and incluiding all fixing accessories complete all as specified and directed. |
| 56 | Supply and fix 35/40 W High efficient LED Street light fitting with pressure die cast LM6 Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie > 100 lumen/watts. The color temperature is around 5700 K with a color rendering index of 70. The luminaire is IP:66 protected with IK05 impact resistance. It has an electronic driver complaint to IEC safety standards with a power factor >0.9, voltage variation range 150-270 V, THD<20%, High and low protection along with a surge protection of 2.5 KV including provision of suitable size GI I light grade pipe of suitable length bend to shape and necessary clamps etc for fixing the light fittings on pole fixed complete Make : CG/Havells/Philips/Orient |
| 57 | S & F in replacement of decorative type wall mounted luminaire (comet) with under take poly carbonate material suitable for 1 x 12 watts LED bulb B-22 base complete all as specified and as directed (Note : 01 piece of LED Bulb rate included in the fittings). |
| 58 | Supply and fix surface ceiling mounted, round/square LED down light fittinground/square LED down light fitting as per requirement at site 10/12 watts, system wattage of 10/12W, system efficacy at luminary level ≥ 80 Lumens/watt, 5700K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete. |
| 59 | Supply and fix recess ceiling mounted, round/square LED down light fitting as per requirement at site 10/12 watts with die cast aluminium housing and system wattage of 10/12W, system efficacy at luminary level ≥ 80 Lumens/watt, 5700K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete. |
| 60 | S&F angle Lamp holder with metallic ring, PVC/Polycorbonate type with back plate complete. |
| 61 | S & F LED bulb 12 watts, 900 lumens output, 6500K suitable for B-22 base . |
| 62 | Refixing of Ceiling fan / exhaust fan/ fresh air including taking down after necessary repairs/ replacement of unserviceable/ wornout part and testing the same as per entire satisfaction of Engr-in- Charge complete all as specified and directed. Note- Spare Parts shall be measured and paid separately under relevant item of supply only. |
| 63 | M&L for opening up the winding of ceiling fan 1200 mm sweep any make and type and rewinding with super enamelled copper winding wire,wraping insulating material, insertion and varnishing well including drying complete. Teating of the ceiling fan after refixing in position to the entire satisfaction of Engr-in-Charge. |
| 64 | S&F in replacement capacitor of 3.15 MFD, |
| 65 | S&F in replacement gun metal bush of any size and make sutiable for ceiling fans 1200 mm compete all as specified and directed. |
| 66 | S&F in replacement ball bearing No. 6202./6203 |
| 67 | S&F in replacement worn out shaft, beyond economical repair of existing ceiling fan any make, type or size as per original one ceiling/exhaust fan complete all as directed. |
| 68 | S&F Ceiling fan blade suitable for 1200mm sweep of any make with suitable size as per site requirement complete all as specified and directed. |
| 69 | M & L for painting of ceiling fans , in situ with synthetic enamel paint by spraying including filling cavities with filler, one or more coat to achieve even and smooth surface after cleaning all dust etc.and endorsement of fan no.with black synthetic enamel paint complete all as directed. |
| 70 | S&F in replacement fresh air fan copper winding motor 230 volts, 50 Hz suitable for 250 mm size exhaust fan complete all as directed. |
| 71 | S&F in replacement exhaust fan copper motor capacity 1/4 HP 230 volts suitable for 300 mm size fresh air fan complete all as directed. |
| 72 | S&F in replacement exhaust fan copper motor capacity 230 volts, AC, 50 Hz suitable for 450 mm size exhaust fan complete all as directed. |
| 73 | Taking down carefully geysers 25/35/50 ltrs capacity opening for inspection reassembling and re-fixing in position after carrying out repairs rates included for replacement of pressed rubber gasket nuts, bolts etc complete all as directed. Note- Spare Parts such as tank, apparatus plate, outer body shall be measured and paid separately under relevant item of supply only. |
| 74 | S&F in replacement only base plate assembly (confirming to ISI ) complete for 25/35 Ltrs capacity copper tank geyser including inlet, outlet and thermostat pipe with drain plug and screws for fixing the element inclusive of clamps for holding the elements with nut, bolts & air release valve suitable for any type/make of geysers installed at site as directed. |
| 75 | S&F in replacement of thermostat for 25/35/50 ltrs capacity of geysers complete all as directed. |
| 76 | S&F in replacement heating element of 2 KW any type, any capacity, any type & any make with nut bolt washer complete all as directed. |
| 77 | M&L for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge. |
| 78 | M & L chromium plated copper connection pipe 15 mm dia & 600 mm long with two brass adopters and connecting up complete all as directed. |
| 79 | Supply only inner still tank for geysers of capacity 25/35 ltr as per existing of approved make complete all as directed. |
| 80 | Supply and fix MCB DB SPN 8 way Horizontal, IP - 30 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar, neutral link earth link complet. |
| 81 | Supply and fix MCB DB SPN 12 way Horizontal, IP - 30 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and SP MCBs as out going with tinned copper bus bar, neutral link earth link complet. |
| 82 | M&L MCB SPN 40 Amp \\"C \\" curve all as directed. |
| 83 | M&L MCB SP 6 to 32 Amp \\"C\\" curve all as directed. |
| 84 | Supply & fix in repair factory made epoxy powder coated Distribution Board VTPN-4 ways (IP-54 protection), mechanical impact strength IK - 09, with cement spill protector double door fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amp copper bus bar, neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one MCCB 125/160 Amp as incomer and 40 to 63 Amp SP MCBs outgoing complete all as specified Note :- MCCB & MCB will be measured & paid separately. |
| 85 | Supply only in repairs MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting. |
| 86 | Supply only in repairs MCCB 125 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting. |
| 87 | Supply only in repairs MCCB 100 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting. |
| 88 | S&F sheet metal enclosure single pole and Neutral with a two pin earth plug and socket complete with a MCB SP 20 Amp 230 volts, 50 Hz, 10KA breaking capacity complete. |
| 89 | Supply & Fixing in replacement modular mini AC box with MCB 20 Amp complete with metal box and 3 Pin, 15 Amps plug top complete all as specified and directed. Make : Indo Asian/Havells/Legrand/ABB Note : Rates are inclusive of cutting / chases for mounting Modular metal box concealed in wall and making good to the disturbed surfaces with OBD / colour wash / white wash and wall putty where ever is required. |
| 90 | M & L for earthing complete with galvanized steel earth plate 600x600x6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of the plate not less than 1.50 mtr below normal ground level, connected to earth lead GI 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron and connection to main switch board of panel, including watering pipe GI 20 mm bore light grade 15mm bore for earthing lead, wire mess, funnel, salt, charcoal dust, excavation and refilling pit with PCC 1:2:4 type B1(using 20mm dia stone aggregate) reinforced with 6mm dia round bar @ 75mm cement concrete both always with MS handle 12mm dai and frame all as shown in electric plate No 3 in page 497 of SSR Part I (2009) including testing ion completion all as directed |
| 91 | M & L for earthing electrode 17.2 mm dia 3 mtrs long of low carbon steel electrode with copper bonding of thickness 250 micron, black-fillearthing enhancing compound AXIS ULTRA/AXIFILL type carbon based compound conductive concrete type which has a resistivity of less than 0.12 ohm Mtr as per clouse 14.5 D of IEEE:80 complete standard. Black fill compound should be electronically conductive (like in metals) and should bedepend on moisture for conduction. Black-fill compound should be environment friendly & should be solidify when mixed with water set like concrete and should not letch/diffuse into the ground. Black - fill compound shall not be mixed with any soil whiling pouring in the bore hole. Test certificate as per IEC:62561-7 for black fill compound shall be submitted along with the material including SS clamp to be provodeboth side and PVC EARTH PIT 300 X 300 MM WITH PLASTIC LID complete all as specified. Note : (i) Earth electrode should be applicable standards IS : 3043, IEC62561-2 & IEC 60364 -5 ans made of High Tensile steel rods copper bounded, High Tensile strength, good electrical conduction& effective performance and suitable for all types of soil and provided minimum distance 3 mtrs. (ii) Black-fill compound should be Compliance to the standards IEEE: 80, IS -3043, BS 7430, IEC 62561-7, ANSI/NSF 60 Certification . (iii) Positive low resistance electrical connection to the earth . (iv) Does not contain hazardous chemicals. (v) Electrinically conductive (like in metals) and is not dependent on moisture (vi) Provide the desire value of earthresistance as per required specified values. (vii) Provide the Exothermic welding joints to entire grid system joints of earthing electrode (viii) Test certificate to be provide of each electrode Make : OBO betterman/ Globetak/Axix |
| 92 | Supply & Fix all accessories of PCB BLDC ceiling fan including remote any type, any make & any capacity including taking down carefully ceiling fan & refixing the same as per requirement at site complete all as specified & directed by Engineer-in- Charge |
| 93 | S & F PVC canopy upper & lower of ceiling fan of any size & make complete with nuts, bolts & washers complete all as specified & directed by Engineer-in-Charge |
| 94 | Taking down old unsv downrod and S & F 1.5/2 feet long Ceiling fan rod (as per sire requirement) duly made out of mild steel incl taking down & refixing of existing ceiling fan of any sweep and make & making connection from ceiling rose of PVC connector complete all as specified & directed. |
| 95 | Taking down old unsv down rod and S & F 3 feet long Ceiling fan rod (as per sire requirement) duly made out of mild steel incl taking down & refixing of existing ceiling fan of any sweep and make & making connection from ceiling rose of PVC connector complete all as specified & directed. |
| 96 | Taking down old unsv ceiling fan rotor & S and F new rotor of ceiling fan of any sweep & make & making in good condition complete all as specified & directed. |
| 97 | S & F in replacement only of ceiling fan housing body parts complete all as specified and as directed by Engineer-in-Charge |
| 98 | S & F in replacement only spring of ceiling fan complete all as specified and as directed by Engineer-in-Charge |
| 99 | S & F in replacement only motor screw of ceiling fan complete all as specified and as directed by Engineer-in-Charge |
| 100 | S & F in replacement only capacitor clamp of ceiling fan complete all as specified and as directed by Engineer-in-Charge |
| 101 | S & F in replacement only blade screw of ceiling fan complete all as specified and as directed by Engineer-in-Charge |
| 102 | S & F in replacement only rubber clamp of ceiling fan with nuts, bolts & washers & safety pin complete all as specified and as directed by Engineer-in-Charge |
| 103 | S & F in replacement PVC cable copper conductor multistranded flexible wire 23/0.0076 twin core & making connection from ceiling rose to fan complete all as specified and as directed by Engineer-in-Charge |
| 104 | Taking down old unsv ceiling fan starter & S and F new starter of ceiling fan of any sweep & make & making in good condition complete all as specified & directed by Engineer-in-Charge. |
| 105 | S&F exhaust fans AC single phase 230/240 V of size 300 mm sweep, Air flow rate > 900cum/min, Bird screen for protection against birds, double ball bearing, heavy duty, metal body with blade, frame & louvers for fixing of exhaust fan complete. |
| 106 | S&F exhaust fans AC single phase 230/240 V, 50 Hz of size 450 mm sweep, Air flow rate > 900cum/min, Bird screen for protection against birds, double ball bearing, heavy duty, metal body with blade, frame & louvers for fixing of exhaust fan complete. |
| 107 | S&F fresh air fan PVC body air delivery > 800 CMH , 5 number of blades, AC single phase 230/240 V, 50 Hz of size 250 mm sweep with louvre fixed complete with suitable size ply by cutting into suitable size as required complete all as specified and directed by Engr-in-Charge. |
| 108 | S & F wall fan 400 mm 3 blade in replacement sweep metal type including provision of 3 core PVC insulated sheathed 1100 volts grade flexible cable with stranded copper conductor, length as per requirement at site complete all as specified and directed by Engineer-in-Charge. |
| 109 | Supply and fixing BLDC ceiling fan, three blade, Robust and reliable inverter motor (brush less DC Motor) powered by ECM technology, BEE 5 star rating for energy saving, rated Air delivery > 220 cum/min, AC single phase 230/240 V of size 1200 mm sweep including fan regulators,down rod, fan canopy, remote of fan with battery & all accessories including making connection with three core flexible, copper winding in fan,copper cable pvc insulated of suitable length, complete including taking down & deposit to MES store of old unsv ceiling fan of capacity 1200 mm sweep all as specified and directed all as directed. |
| 110 | Supply & Fix in replacement fresh air fan blade any make, any capacity as requirement at site all asspecified & directed. |
| 111 | Supply & Fix in replacement exhaust fan fan blade any make, any capacity as requirement at site all asspecified & directed. |
| 112 | Supply & Fix in replacement fresh air fan PVC cup/check nut as requirement at site all asspecified & directed. |
| 113 | Supply & Fix in replacement Rechargeable bulb of capacity 15 watts as requirement at site all asspecified & directed Make : Philips/Havells/CG. |
| 114 | S & F in replacement water heater storage type Geyser ABS body vertical type with suitable size of fastner and including provision and connecting up of SS braidedpipe with adopter for inlet and outlet water connection having adjustable knob for temperature control and inner tank should be glass line coated, capacity 25 Ltrs, having heating element 2 KW and not less than 5 star rating, suitable for ,230 volt, 50 Hz electric supply complete including taking down & deposit to MES store of old unsv geyser of capacity 25 liters all as specified and directed . |
| 115 | Supplying & Fix in replacement 1100 volts grade 6 sqmm heavy duty stranded cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspen ded by insulating hangers not more than 1 metre apart including 4 mm suspension wire, one twin core cable flat or circular |
| 116 | Supply and fixing of outdoor type luminaire post top luminrare (prince opera midi) of 240V, 50hz of capacity 40 watt LED luminare ip 65 suitable for mounting on 6 0mm OD pipe on necessasry PCC works incl all fixing arrangaement complete all as specified and directed Make :Cat Part No : LPTO-40-CDL-M of CG or equivalent in Philips/C&S Cat Part No : LTGLC40WHPLED/W |
| 117 | Supply and fixing LED Bollard with round top 10 W ,220V 50Hz with opal acrylic IP 65 protection along with necessary PCC foundation cable condits for loop in and out , cable connectors complete all as specified and directed Make Cat No. LBLSN-10-CDL of Crompton graves or equivalent in Bajaj / Havells/Philips 58167 YOB PEDESTAL |
| 118 | S&F flood light of capacity 100 watts High efficient light fitting with pressure die cast Aluminum housing and has lenses specially designed for flood Lighting with polycarbonate cover. System level efficacy of the Luminarie > 100 lumens /watts. The color temperature is around 5700 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor >.0.9, voltage variation range 150-270V, THD<10%, High and low protection along with a surge protection of 2.5 KV including provision of suitable dia clamps, nuts, olts & washes etc for fixing the light fittings on wall fixed complete as specified and directed. |
| 119 | S&F in replacement capacitor of 1.50 MFD. |
| 120 | Schedule of Credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender