Tender For Repair/ Replacement Of Doors, Wardrobe With Wpc Shutter And Ceiling Work In Dk-Ii In The Area Of Age B/R-I Including Repair/Replacement Of Pump And Connected Accessoried Of Sewage Installation And Misc E/M Work Under Ge (Central) Delhi Can
Tender Overview
Project Description
Tender for Repair/ Replacement Of Doors, Wardrobe With Wpc Shutter And Ceiling Work In Dk-Ii In The Area Of Age B/R-I Including Repair/Replacement Of Pump And Connected Accessoried Of Sewage Installation And Misc E/M Work Under Ge (Central) Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame) |
| 2 | Taking down shutter of area exc 1.00 Sqm but n exc 2.00 Sqm each Resecuring & easing or adjusting without taking down of shutter complete all as specified and directed |
| 3 | Plain, solid, straight chowkats and frames made out of 2nd class hard wood (sal), wrought, framed, rebated on the solid, rounded or chamfered, put together with glue, pinned at joints, supplied and fixed, complete all as specified and as directed by Engineer-in-Charge. |
| 4 | Supply and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminte shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.,complete as specified by the manufacturer and as per directions of Engineer-in-charge |
| 5 | Supply and fixing to existing door frames 30 mm thick Glass Fibre Reinforced Plastic (FRP) panelled door shutter of required colour and approved brand and manufacture, made with fire - retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate for forming hollow rails and styles, with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5 mm thick FRP laminate for panels conforming to IS: 14856, including fixing to frames, complete as specified by the manufacturer and as per directions of Engineer- in-charge |
| 6 | S & F Glazed and skelton shutters 35mm open rebated and prepared to receive glass, gauge etc edges of framing plain champered or rounded fitted with cut & metered beads for securing glass etc sized of membane shutter as specified in SSR Part I Section 8, Clause 8.23 (a) supplied and fitted to chowkhats, 35mm thick 2nd class hard wood. |
| 7 | S&F for 30 mm thick second class hard wood plain framed factory made Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as directed by engineer-in-charge. |
| 8 | S&F for galvanise Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanized iron staples including wooden beadings, complete all as specified and directed. |
| 9 | Supply and fix 300mm long, Aluminium alloy anodised, sliding door bolt matt finish snot less than 16 mm dia bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts extruded section or cast aluminum alloy, complete all as specified. |
| 10 | Taking down chowkhat or frames of door/ window / ventilators with shutter(Without taking off shutter from the frame) n.exc 1.50 m each. |
| 11 | Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant 152 SECTION 8 and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately).Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 12 | Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. (Note: stainless steel butt hinges and necessary S S screws shall be paid separately) |
| 13 | S&F 150mm long extruded alumiunium alloy handle fabricated type anodized (D type). |
| 14 | S&F 150 mm size aluminium, anodised barrel tower bolts of extruded section and fixed to shutter complete |
| 15 | S&F 100 mm long (size) butt hinges medium weight, cold rolled, mild steel, complete all as specified. |
| 16 | S&F Powder coated aluminium windows and ventilator fixed having aluminium section weighing 0.55 kg/m including necessary jointing cleat glazing clips rubbers packing anodized including sheet glass 5.5 mm thick complete all as specified. |
| 17 | S&F Powder coated aluminium windows and ventilator shutters, side hung type with sash bars,purposely made for fixing window type air conditioners,exhaust fans etc;aluminium section weighing 0.55 kg/m two nos. of aluminium coated 100 mm long tower bolt,one no. 100 mm long aluminium handle , One no. 150 mm long Aluminium peg stay,two nos aluminium coated 100mm long Hinge ,rubber beading , in each window shutterscomplete all as specified. |
| 18 | S&F powder coated aluminum frame for windows/ventilators with one or more rebates including grills, jointing cleats for fixing etc complete all as specified. |
| 19 | S&F sheet glass selected quality 5.5 mm thick for aluminium windows complete all as specified . |
| 20 | Dismantling boarding any description (board/plywood) fixed in any position with screw, complete all as specified |
| 21 | S&F WPC board, S&F factory made 18mm thick single extruded WPC (Wood Polymer Composit) Solid Board having density not less than 600 kg/ Cbm one side white and other side of board laminated with PVC Foil including finishing all edges at all level for making edge lipping /beading or .. 50 mm thick PVC sheet lipping at all 4 edgesusing binding tape, Solvent, screws, stainless steel, Piano hinges / self closives box type hinges etc Manufactured by ISO 9001-2008 certified company. |
| 22 | S&F Hasp and staple, 100mm size, safety type, aluminium anodised brass hinge pin including bolt to hinge plate & fixed with screws, complete all as specified. |
| 23 | S&F continuous (Piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) 30 mm, complete all as specified. |
| 24 | Dismantling false ceiling boards any description and in any position incl frame work. |
| 25 | Providing & fixing false ceiling with fully perforated 12mm thick micro tegular edged or 10mm thick square edged GRG False ceiling tiles at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick(galvanized @ 120 grams per sqm including both sides) comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of s1ze 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1 OOOmm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in- |
| 26 | M & L for dismantling centrifugal pump coupled with electric motor capacity 12.5 HP 3 phase 415 V of overhauling the pumpsets including cleaning with kerosene/petrol for removing the scales and replacement of necessary parts of case ring, latern ring, shaft sleeve, CI gland covers with MS studs, ball bearings, coupling key, rubber bush nut & bolts, impeller key, lock washer, gasket, and greasing, re-assembling same in position, testing and commissioning complete all as specified and directed by the Engr-in-Charge. |
| 27 | M & L for dismantling centrifugal pump coupled with electric motor capacity 25 HP 3 phase 415 V of overhauling the pumpsets including cleaning with kerosene/petrol for removing the scales and replacement of necessary parts of case ring, latern ring, shaft sleeve, CI gland covers with MS studs, ball bearings, coupling key, rubber bush nut & bolts, impeller key, lock washer, gasket, and greasing, re-assembling same in position, testing and commissioning complete all as specified and directed by the Engr-in-Charge. |
| 28 | M&L for strip opening of motor of sewage monoblock pupm set and taking out burnt windings,cleaning of motor rotor and stator with cleaning material,carrying out necessary machining work such as grinding, metaling and polishing and rewinding of motor with stove enamelled copper wire of existing gauge,replacement of unserviceable parts as required. Assembling of motor and testing complete upto entire satisfaction of Engineer-in -Charge for 12.5 HP motor including trasportation fro and to workshop and refixing it to its original position and making necessary electrical connections and testing on completion. |
| 29 | M&L for strip opening of motor of sewage monoblock pump set and taking out burnt windings,cleaning of motor rotor and stator with cleaning material,carrying out necessary machining work such as grinding, metaling and polishing and rewinding of motor with stove enamelled copper wire of existing gauge,replacement of unserviceable parts as required. Assembling of motor and testing complete upto entire satisfaction of Engineer-in -Charge for 25 HP motor including trasportation fro and to workshop and refixing it to its original position and making necessary electrical connections and testing on completion. |
| 30 | Taking out defective sluice valve of any dia/make and supply, installation testing and commissioning of Sluice valve with hand wheel, CI, 100 mm dia ,PN-1.6 type, complete with spindle and all other accessories, complete flanged type, ISI marked and making of necessary connections with pump and supply or delivary line or as directed at site complete as specified. |
| 31 | Taking out defective NRV of any dia/make and supply, istallation testing and commissioning of non return valve CI, 100mm dia PN-1 type, ISI marked complete with spindle and all other accessories, flanged type, and making of necessary connections with pump and supply or delivary line or as directed at site complete as specified. |
| 32 | Taking out defective foot valve of any dia/make and supply,connecting and testing CI foot valve 100mm dia complete with flanged type ISI marked. |
| 33 | M&L for lifting/taking out suction pipe of any dia/size and supply in replacement including fixing/connecting and lowering down suction pipe GI medium grade 100mm dia ISI marked with nuts bolts and washers etc and testing on completion upto entire satisfaction of Engr-in-Charge. |
| 34 | M&L for lifting/taking out delivery pipe of any dia/size and supply in replacement including fixing/connecting delivery pipe CI medium grade 100mm dia ISI marked with nuts bolts and washers etc and testing on completion upto entire satisfaction of Engr-in-Charge. |
| 35 | S&F in replacement GI/CI bend heavy duty 100mm dia ISI marked. |
| 36 | Taking down broken/defective rubber coupling and supply and fixing in replacement tyre/rubber coupling set including necessary jointing materials such as nuts, bolts and washers all as specified and directed by Engineer-in-Charge. Make : As per sample |
| 37 | S& F in replacement ball bearing suitable size all as specified and directed by Engineer in Charge. Make : As per sample |
| 38 | S& F in replacement Volt meter digital type suitable size all as specified and directed by Engineer in Charge. Make : As per sample. |
| 39 | Supply and fix in replacement three phase VAFPF (Voltage, Amp, Frequency and Power factor meter) in pump house electric panels with accuracy class 0.5 operating voltage 430 Volts including making necessary electrical connection with suitable size copper multi stranded cable all as specified. |
| 40 | Supply and fix (welding) in repair at site MS flange heavy duty complete with nuts bolts and washers 06 nos suitable for 100 mm dia GI pipe complete all as specified and directed. Note :1. Taking out pipe from trenches/delivery/raising mains and relaying 2. Welding at site shall be done with portable welding set. Welding set shall be arrange by the contractor. |
| 41 | M&L for de-sludging of existing sewage sump of 20 feet deep by super sucker machine with vaccum and jetting system and sucking up sludge, debris and liquid in storage tanks including hazarduos material with the help of large diameter pipes completely by mechanical means or manually and providing necessary safety equipments to the worksmen deployed all as specified and directed by Engineer in charge and stoarge of sludge in closed container and transporting it to outside of MOD land including transportation and T&P charges.NOTE:- (i) Contractor is advised to visit the site before quoting the rates.(ii) Deposited sludge of any thickness or girth shall be removed from the well of 21 feet dia and depth not less than 20 feet upto visible bottom surface of well irrespective of time/hours/manpower deployed in de-sludging work of well either mechanically or manually.Note: This 20 feet depth is actual accumulated sludge depth which has to be removed from collection well and overall depth including empty well depth may vary at site.(iii) Contractor shall be bound to work in running system of sewage supply of that area. If de-sludging work is executed through manpower deployed by the contractor, Mechanical system shall also be put into work to drain the raw water from the well simulteniously so as not to hamper sewage supply system and no extra cost shall be paid on account of this.(iv) Contractor shall be responsible for testing of any hazarduous gas inside the well or collection chambers before starting work at site. Neutralization of such harmeful and hazarduous gases like Methane, Carbon Dioxide and Ammonia etc shall be the responsibility of contractor and department shall not be responsible for any untoward or fatal incidence at site due to any negligence done by contractor at site.(v) Cost of all T&P required for de-sludging work of sewage system, First Aid, Safety measures and insurance of employee deputed by the contractor shall include in unit rate quoted by the contractor.(vi) Contractor will arrange extra pipes of suitable dia/size upto any distance, in case roads/approach is not feasible for super sucker mahine or collection tanks to reach the nearest site of sewage well and no extra cost shall be paid to contractor on account of this.(vii) If contractor is willing to execute work manually, adequate manpower shall be deployed by the contractor along with necessary T&P and saftey equipments. Manpower deployed by the contractor shall be professionally sound and experienced in concerned field.(viii) Contractor will repair all infraustructure of sewage installation, if damaged during cleaning or de-sludging work and no extra cost shall be paid to contractor on account of this.(ix) After completion of de-sludging or cleaning of deposited sludge of any thickness, contarctor will have to physically show the sludge less clear bottom surfce of collection well by draining out all raw water/ diverting sewage supply at site upto entire satisfaction of Engineer-in-Charge. |
| 42 | M&L for de-sludging of existing sewage sump of 20 feet deep and 15 feet dia by super sucker machine with vaccum and jetting system and sucking up sludge, debris and liquid in storage tanks including hazarduos material with the help of large diameter pipes completely by mechanical means or manually and providing necessary safety equipments to the worksmen deployed all as specified and directed by Engineer in charge and stoarge of sludge in closed container and transporting it to outside of MOD land including transportation and T&P charges.NOTE:- (i) Contractor is advised to visit the site before quoting the rates.(ii) Deposited sludge of any thickness or girth shall be removed from the well of 15 feet dia and depth not less than 20 feet upto visible bottom surface of well irrespective of time/hours/manpower deployed in de-sludging work of well either mechanically or manually.Note: This 20 feet depth is actual accumulated sludge depth which has to be removed from collection well and overall depth including empty well depth may vary at site.(iii) Contractor shall be bound to work in running system of sewage supply of that area. If de-sludging work is executed through manpower deployed by the contractor, Mechanical system shall also be put into work to drain the raw water from the well simulteniously so as not to hamper sewage supply system and no extra cost shall be paid on account of this.(iv)Contractor shall be responsible for testing of any hazarduous gas inside the well or collection chambers before starting work at site. Neutralization of such harmeful and hazarduous gases like Methane, Carbon Dioxide and Ammonia etc shall be the responsibility of contractor and department shall not be responsible for any untoward or fatal incidence at site due to any negligence done by contractor at site.(v) Cost of all T&P required for de-sludging work of sewage system, First Aid, Safety measures and insurance of employee deputed by the contractor shall include in unit rate quoted by the contractor.(vi) Contractor will arrange extra pipes of suitable dia/size upto any distance, in case roads/approach is not feasible for super sucker mahine or collection tanks to reach the nearest site of sewage well and no extra cost shall be paid to contractor on account of this.(vii) If contractor is willing to execute work manually, adequate manpower shall be deployed by the contractor along with necessary T&P and saftey equipments. Manpower deployed by the contractor shall be professionally sound and experienced in concerned field.(viii) Contractor will repair all infraustructure of sewage installation, if damaged during cleaning or de-sludging work and no extra cost shall be paid to contractor on account of this.(ix) After completion of de-sludging or cleaning of deposited sludge of any thickness, contarctor will have to physically show the sludge less clear bottom surfce of collection well by draining out all raw water/ diverting sewage supply at site upto entire satisfaction of Engineer-in-Charge. |
| 43 | S&F not less than 35W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 110lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected, power factor>.0.9, voltage variation range 180-270V, including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. |
| 44 | Supply only seamless electrical hand gloves large size full finger confirming to IS:4770-1991 made out of latex rubber of suitable insulation class for working voltage of 440 volts 3 phase 50 Hz electric supply complete all as specified. |
| 45 | S&F insulation mat for electrical purposes for working 1.1 KV, of class 'B' confirming to IS 15652/2006, ISI marked, high die electric strength up to 65 KV, No adverse effect of acids, alkalis and transformer oil, suitable for both AC & DC electrical installations, high tensile strength, upper surface of mat to make surface Anti-skid, working temperature of range -10° to +60°, the mat shall be water & moisture proof of size 2mtr x 1mtr x 20 mm. |
| 46 | Supply and fix in replacement fully automatic star delta starter enclosed in sheet enclosure for sewage pump motor AC, 3 phase 50 Hz of capacity 10 HP to 15 HP rating complete including making necessary electrical connections all as specified and directed. |
| 47 | M&L for earthing complete with galvanized steel earth plate 600 x 600 x 6.0 mm thick, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized iron strip 25 x 4 mm as earthing lead by means of bolts, nuts, check-nuts, and washers of galvanized iron or steel besides welding at all joints including excavation and earth work, GI pipe light grade 40 mm bore for protection of G.I. strip from earth electrode to the Main switch/Distr Board, supplying and laying charcoal dust, common salt, PCC 1:2:4 type B-1 using 20mm graded stone aggregate chamber and MS angle iron frame 40 x 40 x 3 mm and RCC cover 40 mm thick RCC (1:2:4) type B-1 using 20 mm graded stone aggregate reinforced with 6 mm dia round bars @ 75 mm C/C both ways with MS handle 12 mm dia, round, GI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in Plate No. 3 of SSR Part I of 2009 and connected to earth test point including testing complete all as specified & directed. |
| 48 | Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as galvanized iron strip 25 x 4 mm. |
| 49 | Supply, installation, testing and commissioning of three phase centrifugal pump and motor set coupled, having induction motor 10HP/7.5 KW, 415 volts, not less than 1450 RPM, insulation class 'F', SP-55 including mounting frame of MS channel of suitable size and nuts, bolts and washers duly grouted in PCC foundation of ratio as recommended by OEM for anti vibration support of pump and motor, surface mounted motor ,coupled, solid handling including self priming non clog sewage pump with stainless steel impellor, rubber coupling and coupling guard frame,1450 RPM total head 19 mtr, discharge 28 ltr/sec, head range 10-28 mtr, size 100x100mm, directly coupled with motor by means of rubber coupling complete with mechanical sealing and making all electrical and pipe connections of any dia/type and testing on completion upto entire satsifaction of Engr-in-Charge all as specified and directed. Note: PCC shall be measured and paid separately. |
| 50 | Supply, installation, testing and commissioning factory fabricated and tested LT Panel board Indoor type,made out of CRCA sheet not less than 2mm thick,CPRI approved, platform mounted of suitable size, 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system having bus bar chamber with insulated electrolytic copper bus bars of capacity 250 Amps rating installed on DMC insulators with bus bar chamber, cable alley,dust and vermin proof, IP-42, front opening type with aprons for cable entry, with proper ferrule & cable gland, prewired with PVC insulated multistranded copper conductor FRLS cable of suitable size but not less than 1.5 sqmm complete 1100 volts grade mounted at suitable working height with adequate workable ground clearnce on MS frame not less than 50x50x3mm having anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey RAL- 7035 shade and comprising of the following:- BUS BAR CHAMBER:- (a) 250 Amp three phase and neutral copper conductor, with color coding with heat shrinkable sleave and shall be mounted on non-hygroscopic, non-combustible, high strength DMC material, inter connection of all incomings & outgoings.INSTRUMENT CHAMBER:- (i) Volt Meter 96mmx96mm,flush type rated 0-500V, Digital type with selector switch- 01 Set. (ii) Amp Meter,96mmx96mm,flush type rated 0-200 Amps digital type with suitable size CT's (for three phase)- 01 Set . (iii) RYB Phase indicating lamp LED type with MCB 20A SP 'C' Series- 1 Set of three. INCOMING:- (i) MCCB 125 Amps 25 KA , 4 Pole with adjustable thermal magnetic release-01 Nos. Make of MCCB:- Siemens / Legrand/ Schneider.OUTGOING:- (i) MCCB 4 Pole 63 Amps, 415 volts, 50Hz, 16 KA-03 Nos. (ii) MCB 2 Pole 10 Amps, 415 volts, 50Hz, 10 KA-01 Nos. (iIi) Automatic star delta starter for 10 HP to 15 HP Motor three phase 415 Volt -02 Nos , Make : Havells/L &T or Equivelent. (v) Panel wiring for control circuit with copper cable 1.5 sqmm & power wiring minimum 4 Sqmm PVC insulated 1100 volts grade. (vi) PCC of suitable ratio for foundation etc. |
| 51 | Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth strip 25x4 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 3 of MES SSR part-I. (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 15 mm nominal bore medium grade GI protection pipe 7.5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing. |
| 52 | M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 25x4mm galvanised iron strip. |
| 53 | Supply and fixing Aluminium strip 25x3.15mm fixed with saddles and fixing screws for roof conductors and down conductors above ground and connecting it with earth lead all as specified and directed at site. |
| 54 | Supply and fix air termination rod single pointed Aluminum rod 12mm dia 300mm long including all fixing materials such as nuts, bolts and washers etc all as pscified and directed. |
| 55 | M&L test point terminal block made of Gun metal or phosphorous bronze size 75x75x25mm drilled and screwed including 03 Nos 8mm dia 25mm long hexagonal screws complete. |
| 56 | M&L tube medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid on floors of dia 100mm including all accessories and fittings and welding etc as required at site all as specified. |
| 57 | M&L tube medium grade galvanised with all fittings and fixed complete to walls and ceiling or laid on floors of dia 40mm including all accessories and fittings as required at site all as specified. |
| 58 | S&F single runs of 16 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable drawn through and including 25 mm dia non metallic PVC conduit and conduit accessories on surface of walls/ceiling etc and making necessary electrical connection by means of suaitbale size lugs, nuts, bolts and washers as required at site complete all as specified and directed. |
| 59 | M&L for providing cement concrete in roof kerbs or mud stops, rounded or chamferted on edge type B1 1:2:4, (using 20mm graded aggreggate) all as specified and directed. |
| 60 | Supply and fix MCB DB SPN 8 way Horizontal, IP-43 Protection double door 240 V AC 50Hz suitable for mounting of MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar, neutral link earth link complete all as specified. |
| 61 | Supply and fixing in replacement miniature circuit breaker (MCB) of single pole and neutral and current carrying capacity 40 amps 240V 10KA 'C' curve testing and commissioning including making necessary electrical connections by means of suitable size lugs/thimbles all as specified and directed. |
| 62 | Supply and fixing in replacement 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning including making necessary electrical connections by means of suitable size lugs/thimbles all as specified and directed.. |
| 63 | Supply and fixing LED street light fitting 60 watt 230 volts AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp, impact and corrosion resistant including thermal management in multiple optics having IP 66 protection and making neceassy electrical connections all as specified.Note: Copper cable shall be measured and paid separately. |
| 64 | GI bracket 40mm bend to shape including clamps,nuts, bolts and washers and grouting in wall and painting with two coats of black enamelled paint over a red of red oxide primer all as specified. |
| 65 | M&L copper three core cable 1.5 sqmm for connecting street light with connector all as specified and directed. |
| 66 | Taking down of old unsv garden/gate light fittings of any description including service connection/wires of any dia or size and accessories etc complete. |
| 67 | Supply and fixing LED post top light die cast aluminium housing spigot, powder coated top cover opal PC diffuser having IP 65 protection complete of 15 watt all as specified and directed . |
| 68 | Supply and fixing LED bollard light aluminium extrusion, opal, polycarbonate diffuser for spot free lighting having IP 65 protection complete of 10/15 watt including PCC mounting base of suitable size made out of cement concrete of 1:3:6 type C2 (using 40mm stone aggregate) and mounting nuts, bolts and washers etc and making necessary electrical connections with suitable size copper cable all as specified and directed. |
| 69 | Supplying, laying or fixing, jointing and testing LT under ground electric power cable crossed linked polyethylene (XLPE Cable) insulated, 10 sqmm 2 core galvanised steel strip or wire armoured, ISI-7098 Mark, with aluminium conductor mutli stranded, heavy duty 1100 Volts complete all as specified laid in trenches/laid under floor or fixed naked with walls/ on poles/ in ducts / in GI pipes etc. complete all as specified and directed. (Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles / block, Clamps, nuts, Bolts, washres and pipe shall be measured and paid separately under appropriate items). |
| 70 | Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth, for foundations etc. or for shafts, well cess pits, manholes, pier holes, laying of pipe and cables etc. but not exceeding 10 sqm on plan including dressing /trimming sides and levelling/grading & ramming bottom of excavation and getting out in soft/loose soil complete all as specified. |
| 71 | Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified. |
| 72 | Returning, filling in , including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick in soft/oose soil complete all as specified. |
| 73 | Removing excavated material (soil) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the strating point complete all as specified. |
| 74 | Supply, laying and jointing (HDPE) of 40mm dia and pressure rating 6 kgf/cm2 for cable protection including tee,bend,elbow and other accessories complete all as specified and directed |
| 75 | Supplying and fixing (in repairs) Galvanised mild steel tubing, 'Light grade' of 40 mm bore complete with all fittings, laid in trenches/ under roads, drain, paths, fixed to poles/walls with Mild steel clamps, bolts, nuts and washerws complete all as specified of the following bore (Note :- Excavation & Earth work shall be measrued and paid separately) |
| 76 | M&L for sign board made out of chromium nickle based stainless steel frame 304 grade of size 1.50 Mtr x1.50 Mtr and height not less than 3 mtr fabricated with stainless steel frame and pipe of 40mm dia and sheet not less than 3mm thick and mounted/erected on SS pipe of 50mm and writing letter with white radium shade on navy blue background as “SEWAGE INSTALLATION, MILITARY ENGINEER SERVICES, AGE E/M (CENTRAL), GARRISON ENGINEER (CENTRAL) DELHI CANTT” of suitable size as directed by Engr-in-Charge and fixing/grouting it at suitable height including mounting bracket/legs fixed into ground on PCC plateform of suitable size or as directed at site by Engr-in- Charge and including of all welding/grouting in PCC and other materials all as required at site and testing on completion of job. |
| 77 | M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through rigid PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box/M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate,top sheet cover for housing switches, socket out let and fan regulators etc, all as specified and as directed for the followings:- |
| 78 | One light/fan or bell point controlled by one way switch with 1.5 sqmm copper cable PVC insulated FRLS complete. |
| 79 | One 3 pin 5 Amps socket outlet point controlled by one switch on same board with 1.5 sqmm copper cable PVC insulated FRLS complete. |
| 80 | One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board with 1.5 sqmm copper cable PVC insulated FRLS complete. |
| 81 | Ditto all as item No-77 above but with cable 4 sqmm copper cable PVC insulated FRLS complete. |
| 82 | S&F switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified. |
| 83 | S&F Modular socket outlet 2/3 pin 6 Amp socket combined 2 module complete all as specified. |
| 84 | S&F Modular socket outlet 2/3 pin 6A/16 Amp socket combined 2 module complete all as specified. |
| 85 | S&F Modular fan regulator step type 2 module 120W complete all as specified. |
| 86 | S&F bell ding dong AC 230 volt single pole. |
| 87 | S&F bell push modular type 6A single module. |
| 88 | M&L ceiling rose 3 phase polycarbonate isolated body complete. |
| 89 | S&F in replacement LED light fitting 1x20 watts 220 Volts AC decorative type with driver,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 90 | S&F in replacement LED light fitting mirror type with high out put diffuser, 2 feet 10 watt with driver,holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 91 | Supply and fixing lamp holder polycarbonated type with back plate suitable for batten fittings. |
| 92 | S&Fin replacement LED light fitting 1x9 watt/1x10 watt bulkhead luminaries including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 93 | Supply ,install and testing all in one integrated solar LED street light 35 watts with IP-65 protection compact design, pole mounting bracket, microwave based motion sensor for optimising battery autonomy with factory setting dimming profi;e alongwith microwave sensor for run time maximization,all as specified and directed by Engineer-in-Charge.ALL IN ONE INTEGRATED SOLAR LIGHT: Solar panel with lithium ferro phosphate battery and charger built into the luminaire.Make: Philips/Havells/Bajaj or equivalent Cat Part No BRC 010 LED40/765. |
| 94 | Supplying, transporting, erecting in truely vertical octagoanl pole with 'J' bolts,nuts and screws as specified of 7 mtr height, including necessary excavation and earth work, PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C1 as in plinth block and coping, disposal of surplus soil to a distance not exceeding 50m and depositing where directed complete all as specified and directed. |
| 95 | M&L for plain cement concrete 1:4:8 type D2 (using 40mm graded crushed stone aggregate) as in foundation of pole and mass concrete complete all as specified and directed. |
| 96 | M&L for cement concrete 1:3:6 type C2 (using 40mm graded crushed stone aggregate) as in foundation of stay and coping around poles complete all as specified and directed. |
| 97 | M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking,bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia or secring with clips. |
| 98 | M&L 50mm thick PCC 1:2:4 type B-2 using 40mm gradded stone aggregate as in floors finished even and smooth.complete all as specified and directed by Engr -In- charge. |
| 99 | M&L machine pressed precast concrete chemical treated interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade including 25 mm thick sand cusion complete all as specified and directed by Engr -In- charge. |
| 100 | M & L dismantling/taking down of old tiles of any description in any type of floor and supply and fixing nonskid ceramic coloured tiles in floor surface 600x600x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match laid over and including 15 mm thick cement mortar secrewed bed in cm (1:6) including roughing of excluding floor, complete all as specified and directed by Engr -In- charge. |
| 101 | Taking out cement plaster on brick or stone wlls etc including raking out joints, scrubbing down with water etc complette all as specified. |
| 102 | M&L for rendering cement plaster 15mm thick of ratio 1:6 on fair faces of brick work or concrter surfaces complete all as specified and directed. |
| 103 | M&L for rendering white washing on walls/ceiling with one primary and one finish coat or subsiquent coat in any type of surfaces complete all as specified and directed. |
| 104 | M&L for wash basin vetrious china including bottle trap, water inlet pipe and water outlet pipe connection, water tap chromium plated and width not less than 600mm and depth not less than 500mm having bowl depth not less than 200mm including cutting/fixing etc all as reqiured at site. |
| 105 | Dismantling old deteriorated water closet of any description and supply and fixing first quality vetrious china wash down water closet semi pedestal type white colour including all necessary accessories with flushing cystern and making good disturbed surfaces complete in all respect all as specifeid. |
| 106 | Taking down old unsv exhaust fan and supply and fixing Exhaust fan 300 mm sweep(steel Body) , 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan fixing on 19/18mm thick ply size as per site requirement complete including deposoting unsv fans in MES store yard all as specified and as directed. |
| 107 | Supply and fix in repair MCCB 125 Amps, FP 415 volts 16 KA, 4 pole, 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge. |
| 108 | Schedule of Credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender