Defence Statutory Bodies & Commissions/Committees Closing in 29 days TDR #56904570

Tender For Provision Of Deficient Classrooms And Allied Infrastructure For Children School At Naval Base, Kochi

Issued by Statutory Bodies & Commissions/Committees · Ernakulam, Kerala
Tender Value
29 Crore
Estimated cost
Bid Submission
21 Sep 2026
29 days left
EMD
15 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Deficient Classrooms And Allied Infrastructure For Children School At Naval Base, Kochi

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 21-Aug-2026 Corrigendum_1 Date 21-Sep-2026

BOQ

Name of Work:- PROVISION OF DEFICIENT CLASSROOMS AND ALLIED INFRASTRUCTURE FOR CHILDREN SCHOOL AT NAVAL BASE, KOCHI
Sl. No. Item Description
1List of Works
2Total amount of Sch 'A' part-I (Buildings/ Structures)
3Total amount of Sch 'A' part-II (Excavation, Earthwork, Site Clearance & Site Development)
4Total amount of Sch 'A' part-III (Internal water supply)
5Total amount of Sch 'A' part-IV (Internal Electric Supply)
6Total amount of Sch 'A' part- V (External Water Supply)
7Total amount of Sch 'A' part-VI (External Electric Supply)
8Total amount of Sch 'A' part-VII (Lightning Protection)
9Total amount of Sch 'A' part-VIII (Fire Fighting)
10Total amount of Sch 'A' part-IX (Road/ Path/Hardstanding)
11Total amount of Sch 'A' part-X ( Area Drainage )
12Total amount of Sch 'A' part-XI (Sewage Disposal)
13Total amount of Sch 'A' part- XII (Compound wall & Gate)
14Pile FoundationBoring for cast in situ piles 500mm dia through any type of soil/ strata by DMC method using bentonite slurry including removal of bored materials out side MD land etc. complete all as specified and as directed.
15Providing CRS TMT bars 10 mm dia and over, cut to length, bent to shape required incl cranking, bending, sprilly for hooping for columns etc for piles including stiffners etc. complete all as specified and as directed.
16Providing CRS TMT bars 5 mm dia and over but up to 10mm dia as in helical stirrups for piles and binding with mild steel wire etc for piles etc. complete all as specified and as directed.
17RCC M35 Design Mix as per IS-456 with using 20mm graded stone aggregate as in cast in situ bored pile of 500mm dia and 50m length/ etc. complete all as specified and as directed.
18Testing of piles (initial load test) all as per IS (Vertical )for cast in situ 500 mm dia, piles including mobilising and removing the testing equipment from site after testing etc. complete all as specified and as directed.
19Testing of piles (initial load test) all as per IS (Lateral)for cast in situ 500 mm dia, piles including mobilising and removing the testing equipment from site after testing etc. complete all as specified and as directed.
20Testing of piles (Routine load test) all as per IS (Vertical) for cast in situ 500 mm dia. piles including mobilising and removing the testing equipment from site after testing etc. complete all as specified and as directed.
21Testing of piles (Routine load test) all as per IS (Lateral) for cast in situ 500 mm dia. piles including mobilising and removing the testing equipment from site after testing etc. complete all as specified and as directed.
22PCC (1:4:8) type D2 using 40mm graded stone aggregate for concrete layer below grade beam and foundation complete all as specified and as shown in drg etc. complete all as specified and as directed.
23M&L for form work to sides of grade beams and tie beams for rough finished flat concrete surface etc. complete all as specified and as directed.
24RCC M30 Design Mix for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete etc. complete all as specified and as directed.
25Providing CRS TMT bars 10 mm dia and over, cut to length, bent to shape required incl cranking, bending, sprilly for hooping for columns etc for grade beams, tie beams etc. complete all as specified and as directed.
26Providing CRS TMT bars 5 mm dia and over but up to 10mm dia as in stirrups and binding with mild steel wire etc for grade beams tie beams etc. complete all as specified and as directed.
27Internal Water SupplyS & F for Pillar cock auto closing system with 65 mm extension body 15 mm bore, cast copper alloy fancy type, chromium plated, with cup screwed down, high pressure, screwed for iron pipe and fixed etc. complete all as specified and directedMake : Jaguar cat part No. PRS-CHR-031L65 or equivalent in approved list of makes
28S & F for concealed stop cock and flush cock 15 mm bore with fitting sleeve, operating lever & adjustable wall flange for WHB, EWC and sink complete as specified and directed.Make : Jaguar cat part No. CQT-CHR 23083K or equivalent in approved list of makes
29S & F for brass with cromium plated health faucet with 8 mm dia, 1 m long flexible tube chrome finish & wall hook with NRV (back flow preventer) screwed for iron pipe and fixed complete as specified and directedMake : Jaguar cat part No. ALD-CHR-577 and or equivalent in approved list of makes
30S & F for 2 way bib cock 15 mm bore of cast copper alloy, fancy type, chromium plated with adjustable wall flange for health faucet screwed for iron pipe and fixed etc. complete as specified and directedMake : Jaguar cat part No. ORP-CHR 10041PM or equivalent in approved list of makes
31S & F for autoclosing concealed urinals flush valve 15 mm bore with wall flange screwed for iron pipe and fixed etc. complete as specified and directedMake : Jaguar cat part No. PRS-CHR-073 or equivalent in approved list of makes
32Internal Electric SupplyPoint wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with multi-stranded copper conductor 1.5 Sq.mm nominal cross-sectional area, single core PVC insulated and sheathed FRLSH cable 1100 volts grade, ISI-694 marked including heavy duty PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc., ISI marked modular GI flush box of suitable size with inner and outer white plastic plate (same make of approved switch and socket) including PVC insulated multi-stranded copper conductor 1.5 Sq.mm nominal cross-sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the following:
33(a) One light / ceiling fan / exhaust fan / bell point controlled by one 5/6 amps one way switch.
34(b) One socket outlet, three/five pin, 5 Amp, on the same board with other switches, with cables 1.5 sq mm size controlled by one 5/6 amps one way switch.
35(c) One socket outlet, three/five pin, 5 Amp, independent controlled by one 5/6 amps one way switch.
36(d) One light point controlled by 2 Nos. Two Way switches 5/6 Amps.
37Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with multi-stranded copper conductor 2.5 Sq.mm nominal cross-sectional area, single core PVC insulated and sheathed FRLSH cable 1100 volts grade, ISI-694 marked including heavy duty PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc., ISI marked modular GI flush box of suitable size with inner and outer white plastic plate (same make of approved switch and socket) including PVC insulated multi-stranded copper conductor 2.5 Sq.mm nominal cross-sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site for the one 3/5 pin 15/16 amps socket outlet independent.
38Supply and fix exhaust fan, steel body AC single Phase, 230V of size 200 mm sweep with blades, wire frame and louvers all as specified and directed.
39Supply and fixing LED light fitting suspended/surface of wattage not more than 40W, 220V AC, luminous efficacy min 100 lm/Watt and luminous flux not less than 3900 lm, box type with driver, including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete with accessories if required to be suspended as directed by Engineer-in-Charge.
40Supply and fixing LED light fitting mirror type with high output diffuser 2 feet, 10 Watt, 220V AC with luminous efficacy min 100 lm/Watt, decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
41S&F LED light fitting 10 Watt, 220V AC with luminous efficacy min 100 lm/Watt, bulkhead with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver through three core flexible copper conductor cables of suitable size complete, all as specified and directed.
42S&F hybrid solar security light with luminous efficacy 175 lm/Watt along with monocrystalline solar panel of peak wattage 35W, Lithium Ferro Phosphate type battery of capacity min 20Ah, battery voltage 12.8V, charge controller MPPT type of wattage min 17W, fitting shall be made of pressure die cast aluminium housing with IP65 protection and impact resistance of IK08, complete with and including wall mounted bracket fabricated out of 40 mm GI pipe, light grade bend to shape 1.5 m long and two Nos wall mounting clamps using 25 × 4 mm thick MS strip bent to shape and welded with pipe to form solid structure and one run of 1 sq mm PVC insulated multistranded copper conductor wire connecting PVC terminal to fitting.
43Supply and fixing LED High Bay light 150 Watt, 230V AC, outdoor type with luminous efficacy min 150 lm/Watt, with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
44Supply, Installation, Testing and Commissioning of direct drive High Volume Low Speed (HVLS) Fan suitable for mounting on truss ceiling with following specification:(a) Type of Fan: 24 Feet (PMSM) High Volume Low Speed Gear Less Fan(b) Motor: Permanent Magnet Synchronous Motor (PMSM), minimum IP55, rating not more than 1.5 kW(c) Fan Blade shall be made up of extruded engineering grade / high-grade aluminium alloy, number of blades shall not be less than 5(d) Impeller and Hub shall be protected from anti-fall as per standards(e) Drive type: The speed regulation and control of air flow shall be controlled by suitable drives as per OEM recommendations. The drives and controls for HVLS fans shall be enclosed in panel with latest IP standards.(f) Air Flow: The fan shall have air flow of minimum 3,80,000 CFM(g) Noise level: The fan shall have a noise level of less than 50 dB(h) Safety: The fan shall be provided with minimum 4 Nos GI Guy/stay wire rope of diameter not less than 6 mm(j) RPM shall not be more than 60(k) Power Supply: Suitable for 415 V or 230 V AC supply, 50 Hz
45S&F Vertical TPN Distribution Board, 8 way double door, 415 Volts suitable for MCCB 4P of rating up to 250A as incomer and SP/TP MCBs as outgoing with IP43 protection, door earthing, isolated neutral bar, mechanical impact strength IK09, all as directed and as specified.
46S&F Vertical TPN Distribution Board, 6 way double door, 415 Volts with provision for MCB as incomer and SP/TP MCBs as outgoing with IP43 protection, door earthing, isolated neutral bar, mechanical impact strength IK09, all as directed and as specified.
47S&F Vertical TPN Distribution Board, 4 way double door, 415 Volts with provision for MCB as incomer and SP/TP MCBs as outgoing with IP43 protection, door earthing, isolated neutral bar, mechanical impact strength IK09, all as directed and as specified.
48Sheet metal enclosure distribution board MCB DB SPN 6 way with metal double door, 240 Volts with IP-43 protection including door earthing complete, all as specified.
49External Water SupplyCutting existing 300mm bore DI water mains and inserting Tee os size 300x150x300 mm dia for taking branch connection including fittings and lead joints complete all as specified and as directed
50Supply and laying pipe ductile iron, socket & spigot type including specials, rubber gasket, bends class \\"K-9\\", 150 mm(6\\") dia including all connected accessories complete all as specified and as directed.
51M & L Valve chamber of internal size 1.20 m X 1.20 m X 1.20 m (internal dimentions) including excavation of earth work in any type of soil, 150mm thick PCC in 1:4:8 type D2 foundation , brick work in CM 1:6, 15 mm thick rendering in CM 1:4 to both internal and external surfaces upto 150mm depth below GL, PCC 1:3:6 type C1 as in coping, cover with two Nos of hinges and one No. handle made out of MS round bar 10mm dia with necessary locking arrangement including painting to the steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer complete all as shown on drg and as specified. Note:- The estimated cost includes all earthwork and connected items.
52Supply, installing, testing and commissioning of electrically driven centrifugal Pump set as per specification, motor TEFC type, 2900 rpm, 420 V, 50 Hz, 3 ph, class 'F' insulation, IP 55 protection, not less than 5HP, starting on suitable DOL/Star Delta starter. The pump shall be horizontal, end suction, top discharge. The pump shall have cast iron casing, cast iron/bronze impeller(as per manufacturer), carbon steel shaft with common base frame (fabricated mild steel channel frame or cast iron type) placed on RCC (1:2:4) including foundation bolts, nuts etc. complete with antivibrator pad as required capable of discharging not less than 390 LPM at 20 mtr head inclusive of suitable rated 3 ph starter,, air release valve, priming valve 25mmm size, as recommented by the manufacturer, PVC insulated copper cable connection from starter to the motor terminals all as specified and directed by the Engineer-in-charge.Make:- Kirloskar Brothers/ equaivalent.
53Supply and fix Foot Valve ductile iron ball type check valves flanged end in PN 10 with epoxy coating conforming to IS 4038, 65 mm (2.5\\") dia including all connected accessories complete all as specified and as directed.
54Supply and fix non return iron valve cast iron flanged at ends in swing type design, Gun metal type seat conforming to IS 5312, 65 mm (2.5\\") dia including all connected accessories complete all as specified and as directed.
55External Electric SupplySupply, laying, and testing cable XLPE insulated, screened, PVC bedded, Galvanized Steel Strip/Wire Armoured heavy-duty electric power cable 1100 volts grade with stranded Aluminium conductor of size 120sq.mm, 3.5 Core complete all as specified and directed by the Engineer-in-Charge.
56Supply, laying, and testing cable XLPE insulated, screened, PVC bedded, Galvanized Steel Strip/Wire Armoured heavy-duty electric power cable 1100 volts grade with stranded Aluminium conductor of size 50 sq.mm, 3.5 Core complete all as specified and directed by the Engineer-in-Charge.
57Supply, laying, and testing cable XLPE insulated, screened, PVC bedded, Galvanized Steel Strip/Wire Armoured heavy-duty electric power cable 1100 volts grade with stranded Aluminium conductor of size 35 sq.mm, 3.5 Core complete all as specified and directed by the Engineer-in-Charge.
58Supply, laying, and testing cable XLPE insulated, screened, PVC bedded, Galvanized Steel Strip/Wire Armoured heavy-duty electric power cable 1100 volts grade with stranded Aluminium conductor of size 10 sq.mm, 4 Core( Street light & Security lights) complete all as specified and directed by the Engineer-in-Charge.
59Supply, install, testing and commissioning of factory made and CPRI approved/ tested out door type feeder pllar box suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating of suitable 500 Amps for phases and suitable 500Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of double door outer shall of thickness 3.15mm and inner shell of thickness 2mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties inlcuding perimeter chain link fencing around panel and all as per IEC 61439( Location LTP No 1 of schematic plan)
60INCOMING(a) MCCB TPN 250 Amps 36 KA -01 Nos Incoming.(b) Digital volt meter 0-500 Volts-01(c) Digital Ampere meter 0-300 Amps with and including CTs of set of 3 NosOUTGOING(a) MCCB TPN 150 Amps, 25KA -2 Nos For building VTPN panel incomer(b) MCCB TPN 63 Amps - 02 Nos for water supply panel(c) MCCB TPN 63 Amps - 01 Nos for Fire Fighting Terrace panel(d) MCB 415 Volts 25 A SPN - 03 No (security light/ street lights & spare)(e) MCB 415 Volts 40 A SPN - 01 No (for auditorium)(f) Internal wiring of panel with stranded copper cable of suitable size(g) Neon phase indicating lamp(Set of three)-01 Nos(h) Stenceling of pannel board including marking of distribuitions
61Supply, install, testing and commissioning of factory made and CPRI approved/ tested indoor type pedestal mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 200 Amps for phases and 200 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of 2.0 mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties and all as per IEC 61439 :-(Location: (LTP-2 Water supply panel )
62INCOMINGS(a) MCCB 415 Volts, TPN 63 Amps 18 kA - 01 No (Incoming)(b) Digital volt meter 0-500 Volts-01(c) Digital Ampere meter 0-100 Amps with and including CTs-01 No of set 3 NosOUTGOING(a) MCCB TP 32 Amps 18 kA - 02 Nos(b) MCB SPN 16 Amps 6kA - 01 No(c ) fixing 02 Nos DOL starters for 5 HP pumps(d) Digital volt meter 0-500 Volts-01(e) Digital Ampere meter 0-300 Amps with and including CTs(f) Neon phase indicating lamp(Set of three)-01 Nos(g) Stenceling of pannel board including marking of distribuitions
63Supply, install, testing and commissioning of factory made and CPRI approved/ tested Outdoor type pedestal mounted on PCC Plinth. LT panel board cubicle type panel board suitable for 415 volts, 3 phase, 4 wire, 50 Hz AC supply system having bus bar chamber with air insulated PVC sleeved with heat shrink of colour code on copper bus bar of rating 200Amps for phases and 200 Amps for neutral fixed on porcelain insulators. The panel shall be weather proof, dust and vermin proof IP-54 class protection and fabricated out of double door outer shall of thickness 3.15mm and inner shell of thickness 2mm 3.15.mm CRCA sheet duly powder coated after seven tank process and pedestal of size 50 x 50 x 6 mm thick MS angle iron frame work. the panel shall be both front and back openable type adequate space all around acessories sucxh as LT switchgear and measuring instruments on both sides including internal wiring in the panel with PVC insulated multi stranded copper conductor cable 1100 Volt grade IS 694 marked or PVC sleeved copper strips of appropriate size as per standard is practices and comprising of followings acessorties all as per IEC 61439 :-(Location: LTP No 3 - fire fighting Terrace panel)
64INCOMINGS(a) MCCB 415 Volts, TPN 63 Amps 18 kA - 01 No (Incoming)(b) Digital volt meter 0-500 Volts-01(c) Digital Ampere meter 0-100 Amps with and including CTs-01 No of set 3 NosOUTGOING(a) MCCB TP 32 Amps 18 kA - 02 Nos(b) MCB SPN 16 Amps 6kA - 01 No(c )(c ) fixing 02 Nos star delta starters with power contactor,single phase preventor suitable for 15 HP Pump(d) Digital volt meter 0-500 Volts-01(e) Digital Ampere meter 0-300 Amps with and including CTs(f) Neon phase indicating lamp(Set of three)-01 Nos(g) Stenceling of pannel board including marking of distribuitionsof pannel board including marking of distribuitions
65Supply and fix timer switches astro type having longitude and latitude of Indian cities in memory 250 V Single phase of 20 Amp rating with contactor fitted inside street light DB including all fittings complete all as specified and directed by Engineer-in charge.
66S & F LT Cable route marker of Cast Iron type Circle 100 dia including base plate. Note: foundation measured separately of base size 300mmx 300mmx 300mm complete all as specified and as directed.
67S&F of MCCB 250 Amps 36KA , TPN along with sheet metal enlclosure outdoor type 3.15mm CRCA sheet ,CPRI aproved/tested enclosure connected to existing LT pane with bus bar extension at NCS substaion including all necessary accessories complete all specified and directed by engineer in charge.
68Supply,spreading and levelling riddled soil as earth cushioning to UG cable by using IS seive to separate the composite/roots etc and refilling spreading in trenches as cushioning and rammed down to form a solid bed all as specified and directed at site.
69Fire FightingSupply and fix Automatic Air Release Valve (ARV), 50 mm diameter, designed for domestic water with 50 mm gun metal stop valve complete as directed by the Engineer-in-Charge.
70Supply and fix valve, Non return valve arrangement butterfly type, flanged end in swing type with rubber seat, 100 mm (4\\") dia complete all as specified and as directed by the Engineer-in charge.
71LED Emergency exit signage luminaire lit up using regular main supply comes with a unique rechargeable battery capable of emergency backup upto 05 hours and the size, colours of the exit signage shall be as per IS 9457 & IS 12349 complete all as specified and as directed by the Engineer-in charge.
72LED Emergency escape lighting luminaire lit up using regular main supply comes with a unique rechargeable battery capable of emergency backup upto 05 hours and the size, colours of the exit signage shall be as per IS 9457 & IS 12349 complete all as specified and as directed by the Engineer-in charge.
73Earthing complete with GI earth plate electrode size 60 × 60 cm × 6 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 m below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level, surrounded from all sides by mixture of charcoal and common salt and electrode connected by using GI wire 4 mm as earth lead by means of bolts, nuts, check nuts and washers of brass and earth strip protected by GI protection pipe light grade 15 mm dia connected to main earth wire on pole/control board and GI pipe medium grade 20 mm bore for watering, funnel with wire mesh, PCC chamber pit in PCC 1:3:6 type C-1, 40 mm thick precast RCC M-25 (design mix) cover reinforced with 8 mm dia TMT bars @ 10 cm C/C on both sides and handle, excavation and earth work in any type of soil and removal up to 50 m complete all as specified and shown in Electric Plate No. 03 of SSR Part-I (2009), connecting to earthing test point all as specified and directed including testing on completion.
74M & L Earthing complete with Galvanized steel earth plate electrode of size 600mmX600mm, 6.00 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below the normal ground level with top edge of the plate not less than 1.5m below normal GL and connected to galvanized iron strip of size 32 x 6 mm size by means of bolts, nuts, check nuts and washers of galvanized iron steel all as shown in Electrical Plate No.3 connecting to earthing test point, including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 (using 20mm graded aggregate), common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 (using 20mm graded aggregates), with 8mm CTD bars @ 100mm c/c in both ways, including necessary form work complete including necessry test on completion all as specified and as directed. Note : The unit rate shall also include for excavation, earth work in hard/dense soil PCC (1:3:6) type C1 pit, RCC cover slab, GI funnel with 20 mm dia GI medium grade watering pipe, wire mesh, 40mm dia light grade GI protection pipe for earth lead etc., complete.
75Earth continuity conductor GI wire 4 mm dia fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc., as required complete all as specified and as directed.
76Water CoolerSupply, installation, testing and commissioning of water cooler with inbuilt RO and UV purification system comprising of sediment filters, Carbon filters and RO membrane having min filtration capacity 50 Ltrs per hour, having storage tank capacity min 80 ltrs and nominal cooling capacity min 40 ltrs per hour suitable for operation in 230 Volt, 50 HZ AC power supply. Water tank shall be made up of statineless steel of grade SS304 and full body of water cooler shall be made of corrosion resistant stainelss steel, No of faucets shall be 02(01 for cold water and 01 for normal water) with all connected accessories complete conforming to IS-1475 and BIS marked all specified and as directed.
77Spply and fixing Voltage stabilizer for auto operation, single phase, naturally air cooled indoor type and designed for inout variation between 170V to 270V with output voltage stabilizer at 230V with accuracy with in +/- 2.5% and of capacity 2.0 KVA.
78Misc TV & TelephoneSupply and fixing of 2-Module GI (Galvanised Iron) Metal Flush Box complete all as specified and as directed.
79Supply and fixing of 1-Module (1M) Modular Telephone Socket Outlet (RJ-11), with cover plate complete all as specified and as directed.
80Supply and fixing of TV Socket Outlet (1 Module) with cover plate complete as specified and directed by the Engineer-in-Charge.
81M&L Rigid non metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all Tees,bends,elbows,reducers,bell mouth,bell tube ends and fixing accessories such as couplers,lock nuts,saddles,pipe hooks etc, dia of conduit 20mm.
82M&L Rigid non metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all Tees,bends,elbows,reducers,bell mouth,bell tube ends and fixing accessories such as couplers,lock nuts,saddles,pipe hooks etc, dia of conduit 25mm.
83Air ConditionSupply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 TR with inverter compressor technology, R-32 refrigerent, anti dust filter, active carbon filter, anti microbial filter, anti viral filter and heavy duty cooling including provision of suitable bracket fixing arrangement, required copper pipe and insulation including drain pipe of size 20mm PVC upto ground floor as per site requirement complete all as specified and directed by the Engineer-in-Charge. Make:- Blue star/LG/Voltas/Equivalent.
84Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2.of capacity 2 TR with inverter compressor technology, R-32 refrigerent, anti dust filter, active carbon filter, anti microbial filter, anti viral filter and heavy duty cooling including provision of suitable bracket fixing arrangement, required copper pipe and insulation including drain pipe of size 20mm PVC upto ground floor as per site requirement complete all as specified and directed by the Engineer-in-Charge. Make:- Blue star/LG/Voltas/Equivalent.
85Supply and fix Voltage Stabilizer for automatic operation, single-phase naturally air cooled indoor type &, designed for input voltage variation from 170V to 250V AC, and delivering a stabilized output of 230V AC with an accuracy of ±2.5% and of capacity 5 KVA complete all as specified and directed by the Engineer-in-Charge.
86Compound Wall & GateM & L for preparation of new steel surface over 10 cm width or girth and applying two coats of VX polymer-based anti-corrosive paint over a coat of anti-corrosive primer.etc complete all as specified & directed.
87ArboricultureSupply & planting of Bermuda grass (by dibbing method @ 7.5 cm apart) over prepared surface with adequately developed root after providind antitermite treatment including preparation of surfaces, earth work excavation, removing surplus soil, filling of approved earth suitable for grassing 20 cm thick after mixing of fertilizer/organic manure and regular mainteance of developed grass for one year.
88Green Building NormsConsultancy services for obtaining atleast 3 Star rating from GRIHA ADARSH as per GRIHA v. 2019 (i) one block of deficient classrooms and allied infrastructure for children school at Naval Base in (G+2) = 5133.36 SqmNote:a) Submission of documents for registration to certification agency GRIHA after the issue of Job/Work Order.b) Analysis and suggestion of improvement/corrections in the MEP/other relevant drawings/ documts and draft tender of the subject work for GRIHA Star rating (min 3 star)c) Preparation, submission & uploading all the doucmnts online in accordance with the GRIHA requirements, documentation shall be supported by drawings, test reuslts, equipment catalogues & calculations.d) Assisting in the selection of equipment & materials.e) To facilitate the planning team for selection of appropriate energy efficient & eco-friendly technologies, equipment & materials for the building e.g. ligting system, white goods, water treatment technologies, renewable energy, nontoxic paints, rapidly renewable materials, recycled materials, ecofriendly materials etc. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56904570
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 29 Crore
LAST DATE 21-09-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Deficient Classrooms And Allied Infrastructure For Children School At Naval Base, Kochi
Basic Detail
Tender No 891098
Bidding Type Tender
Location
City Ernakulam
State Kerala
Key Dates
Publish Date 21 Aug 2026
Submission Date 21 Sep 2026
Open Date 28 Sep 2026
Finance
Tender Value 29 Crore
Tender Fee 3000
EMD 15 Lakhs
Exemption Available
Document List
Tendernotice_1 (6).pdf
8c6911cf-8fb6-410d-bdf9-8e04335050e9.html
BOQ_877672.xls
Dwg_merged.pdf
Prepriced.pdf
Tender.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Aug 21, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Upcoming · 29 days
Sep 21, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 29 days
Sep 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 36 days

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1 (6).pdf

html

8c6911cf-8fb6-410d-bdf9-8e04335050e9.html

xls

BOQ_877672.xls

pdf

Dwg_merged.pdf

pdf

Prepriced.pdf

pdf

Tender.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders