Tender For Repair/ Replacement Of Gi / Ci Fitting, Bathroom Fixtures, Common Area Repairs 1 Wec, Wee Wksp, Das, Eetsu, Tarang Mess, Galaxy Mess, Aec, 1 Wec Md Accn And Uri Enclave In The Area Of Age B/R-I Including Repair/Replacement And Maintenance
Tender Overview
Project Description
Tender for Repair/ Replacement Of Gi / Ci Fitting, Bathroom Fixtures, Common Area Repairs 1 Wec, Wee Wksp, Das, Eetsu, Tarang Mess, Galaxy Mess, Aec, 1 Wec Md Accn And Uri Enclave In The Area Of Age B/R-I Including Repair/Replacement And Maintenance Of Internal Wiring System Including Replacement Of Electrical Fittings And Fixtures Of Mocular Type Wiring System Alongwith Mcbs, Dbs And Defective Sub Main Wiring Of Offrs Md Accn At Dhoula Kuan Part-Ii Area Under Ge (Central) Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etc complete all as specified and directed |
| 2 | M&L 15mm thick rendering on brick work or concrete surfaces in cement mortar 1:4 finished even and fair. |
| 3 | M&L for rendering 15mm thick in CM 1:6 on fair faces or other than fair faces of brick work or concrete surfaces of walls firnished even and smooth without using extra cement in multistorey building ,complete all as directed. |
| 4 | M & L for 5 mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling, chajja and like surface finished even and smooth without using extra cement incl scafolding etc, complete all as specified. |
| 5 | M & L for applying two coats of oil bond destember over one coat of birla white wall care putty on newly plastered surfaces(internal) of walls complete all as specified and directed. |
| 6 | M&L preparing newly plastered surfaces of ceiling and applying two coats of white wash complete all as specified and directed. |
| 7 | M&L for preparation of old decorated plastered surfaces of ceiling including pilasters and cornices etc , brooming down, etc and applying one coat of white washing complete all as specified and as directed. |
| 8 | M&L for old decorated surfaces plastered or unplastered surface of wall and applying two coat of oil bond distemper over one coat of wall care putty on wall complete all a spcefied. |
| 9 | Taking up or down steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm |
| 10 | Supply and fix galvanized steel tubing, 15 mm bore medium grade including all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors complete all as directed |
| 11 | Supply and fix in repairs vitreous china wash hand basin (flat back) white of size 550X400mm excluding taps, waste chain and plug and porcelain stopper including a pair of mild steel angle iron brackets of suitable size and waste pipe & waste fittings complete all as specified |
| 12 | Supply and fix in repairs vitreous china squatting pan Orissa pattern long pan size 580x440mm white with integral foot rests ‘standard Grade P’ or ‘S’ trap front or back inlet (excluding flushing cistern and flush pipe ) complete all as specified and directed by Engr-in-Charge, |
| 13 | S & F in repairs floor mounted EWC one piece incl all necessary fittings complete all as specified and directed by Engr -in-charge.Note:- Cistern and seat cover paid seperatly.. |
| 14 | S & F in repairs floor mounted EWC incl all necessary fittings complete all as specified and directed by Engr -in-charge.Note:- Cistern and seat cover paid seperatly.. |
| 15 | Supply and fix in repairs PVC low level white flushing cistern valveless syphonic action type 10 lts capacity IS marked with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC, (ISI Marked) complete all as specified. |
| 16 | S&F in repairs PVC waste pipe 32 mm dia for wash hand basin, complete all as specified |
| 17 | S & F in repair 15 mm dia 600mm long PVC connections with brass check nut complete. |
| 18 | S&F in repair CP jet spray for EWC with flexible pipe and angle cock/stop cock complete all as specified. |
| 19 | S&F in repairs bib taps 15 mm bore chromium plated brass, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule, complete all as specified. |
| 20 | S&F in repairs angle valve, fancy type, chromium plated brass, 15mm, complete all as directed. |
| 21 | S&F in repairs 2-in-1 angle valve, fancy type, chromium plated brass, 15mm, complete all as directed. |
| 22 | S&Fin repairs 15 mm dia pillar taps, fancy type brass with capstan head chromium plated screwed down high pressure with or without lettered “hot/cold” with long screwed shank and flynut screwed complete all as specified. |
| 23 | S&F in repairs plastic water closet seat cover white closed pattern with flat bottom end cover and mild steel chromium plated hanging device complete all as specified |
| 24 | Supply and fix in repairs looking mirror of size 600mmx450mmx5.5mm thick with aluminium frame selected quality mounted on 6mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers. |
| 25 | S & F in repair towel rail 600mm long brass chromium plated of 20mm dia (external) and 1mm thickness with gutties embeded in cement mortar 1:3 with MS screws etc complete all as specified and directed. |
| 26 | Demolition of stone slab and tiles of any description or thickness in floor apron etc complete all as specified and directed. |
| 27 | M&L for Non - skid Ceramic colour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or oloured cement to match incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) complete all as specified and as directed. |
| 28 | M&L for glazed ceremic colour tiles (600x300x7mm) thick, in vertical surface etc set and jointed in neat slurry and pointed in white or coloured cement to match with tiles including 10mm thick rendering in cement mortar (1:6) complete all as specified and as directed. |
| 29 | M&L for Non - skid Ceramiccolour tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or oloured cement to match incl 15mm thick screed bed or bedding layers in cement mortar ( 1:6) complete all as specified and as directed. |
| 30 | S&F Non - skid Ceramic colour tiles 600 x600 x 7 to 8 mm thick in floors etc and 15mm thick screed bed 1:6 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified. |
| 31 | S&F Non - skid Ceramic colour tiles 600 x100 x 7 to 8 mm thick in vertical surfaces etc and 10mm thick screed bed 1:4 in cement mortar. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified. |
| 32 | M&L for 18 -20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite. |
| 33 | Demolition of concrete and pavings n.exc 15 cm thickness (below or above ground level) |
| 34 | M&L for cement concrete 40mm thick type B-0, 1:2:4 (using 12.5 mm graded aggregate) as in floor for fair finished surfaces of concrete complete all as specified and directed. |
| 35 | Material and labour for rotational moulded polyethylene water storage tanks white colour 500 lts capacity, triplr layered (cylindrical vertical with closed top) hoisted and fixed in position including 25 mm dia brass float valve and polyethylene ball including fitting and taking out existing unserviceable overhead tank of any description. |
| 36 | Material and labour for rotational moulded polyethylene water storage tanks white colour 1000 lts capacity, triple layered (cylindrical vertical with closed top) hoisted and fixed in position including 25 mm dia brass float valve and polyethylene ball including taking out existing unserviceable overhead tank of any description. |
| 37 | Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge. |
| 38 | M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor FRLS,drawn in and including rigid PVC conduit with conduit accessories concealed in wall/ceiling, medium grade ,ISI marked,terminal box of 1.6 mm thick including sheet cover/Modular cover plate of suitable module for fixing of switches/sockets and regulators etc. including provision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable green colour and connected to common earth dolly complete for the following :- |
| 39 | One light/fan/exhaust fan point controlled by one way switch. |
| 40 | One bell/buzzer point controlled by one bell push |
| 41 | One light point controlled by two Nos two way switches |
| 42 | One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board. |
| 43 | One 3 pin 5 Amps socket outlet point controlled by one way switch on same board |
| 44 | All as per item No 39 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge |
| 45 | Supply and fix white cover plate with frame 2 Module omplete all as specified and directed by Engineer in charge. |
| 46 | Supply and fix white cover plate with frame 3 Module omplete all as specified and directed by Engineer in charge. |
| 47 | Supply and fix white cover plate with frame 4 Module omplete all as specified and directed by Engineer in charge. |
| 48 | M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge. |
| 49 | M&L in replacement switch modular type 6 amp SP two way, 1 module complete all as specified and directed by Engineer in charge. |
| 50 | M&L in replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge. |
| 51 | M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge. |
| 52 | M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate 230V AC complete all as specified and directed by Engineer in charge. |
| 53 | M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge. |
| 54 | M&L in replacement modular stepped type electronic fan regulator 120W, 2 module all as specified and directed by Engineer in charge. |
| 55 | M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge. |
| 56 | M&L in replacement switch piano flush button type single pole two way 6 Amps complete all as specified and directed by Engineer in charge. |
| 57 | M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge. |
| 58 | M&L in replacement switch piano flush button type single pole 16 Amps complete all as specified and directed by Engineer in charge. |
| 59 | M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge. |
| 60 | M&L in replacement socket outlet 6 Amp flush button type complete all as specified and directed by Engineer in charge. |
| 61 | M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed. |
| 62 | M&L in replacement bell electric (dingdong) 230 volt, SP all complete all as specified and directed by Engineer in charge . |
| 63 | M/L in replacement insulated body, angle holder with back plate complete all as specified and directed by Engineer in charge. |
| 64 | S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge. |
| 65 | M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified and directed by Engineer in charge. |
| 66 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, lifetime of 25000 burning hours with 70% of its initial lumen maintained, Power Factor not less than 0.90, colour temperature-6500K, IP-20 protected, voltage range-180 to 240 Volts AC, temperature range 0 to 50 Degree C and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting complete all as specified and directed. |
| 67 | Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts 3 in 1, lifetime of 25000 burning hours with 70% of its initial lumen maintained, Power Factor not less than 0.90, colour temperature-6500K, IP-20 protected, voltage range-180 to 240 Volts AC, temperature range 0 to 50 Degree C and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting complete all as specified and directed. |
| 68 | Supply and fix LED batten luminaire surface mounted, 2 feet system wattage of 10 Watts, lifetime of 25000 burning hours with 70% of its initial lumen maintained, Power Factor not less than 0.90, colour temperature-6500K, IP-20 protected, voltage range-180 to 240 Volts AC, temperature range 0 to 50 Degree C and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting complete all as specified and directed. |
| 69 | Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, with a life class of 25,000 burning hours, Power Factor not less than 0.90, driver with voltage range 180-270V, Temperature range 0 to 50 Deg, colour Temperature-6000K, including connecting up with necessary PVC sheathed 3 core 1.5 sqmm copper conductor flexible wire fixed complete all as specified and directed. |
| 70 | S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge. |
| 71 | S&F in replacement of decorative type single wall mounted light premium indoor with white frosted glass sleek design surface mounted brush finish suitable for LED bulb E 27 base complete including bulb as per manufacturer's recommendation all as specified and directed by Engineer in charge. Model No; BeuHome BW05 of Wipro or equivalent in Havells/Philips. |
| 72 | Supply and fix surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, life time of 25000 burning hours, 6500K colour temperature,Power Factor not less than 0.90, Driver with voltage variation range-180 to 240 Volts AC, including connecting up with PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed complete all as specified and directed. |
| 73 | Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge. |
| 74 | Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge . |
| 75 | Supply and fix MCB DB SPN 12 way Horizontal, IP-43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge. |
| 76 | Supply and fix in repair MCB DP 63 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed by Engineer in charge. |
| 77 | Supply and fix in repair MCB DP 40 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed by Engineer in charge. |
| 78 | Supply and fix in repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'B' curve complete all as specified and directed by Engineer in charge |
| 79 | Supply and fixing ventilating Fan 250mm sweep, 1200 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed. |
| 80 | Taking out old deteriorated casing caping of any description including taking out copper wire of any type alongwith it and supply and fixing new casing caping of 20mm including refixing the copper wire as dismantled earlier alongwith fixing materials such as casing clips and making good disturbed surfaces all as specified and directed by Engr-in-Charge at site complete. |
| 81 | Supply and fixing exhaust fan 300mm sweep (steel Body),1250 RPM, metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed. |
| 82 | Supply and fix wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed. |
| 83 | Supply and fix in repair MCCB 125 Amps, FP 415 volts 16 KA, 4 pole, 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge. |
| 84 | Supply and fix in repair MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge. |
| 85 | Supply & fix in repair factory made epoxy powder coated load line distribution board TPN-4 ways with double door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing conforming to IS : 8623 complete all as specified. |
| 86 | Supply and fix in replacement sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. |
| 87 | Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25mm dia non metalic rigid PVC conduit in walls all as specified and as directed. |
| 88 | Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25mm dia non metalic rigid PVC conduit in walls all as specified and as directed. |
| 89 | S&F plug top, 3 pin, 16 amp (ISI marked) complete all as specified and directed by Engineer in charge. |
| 90 | S&F plug top, 3 pin, 6 amp (ISI marked) complete all as specified and directed by Engineer in charge. |
| 91 | S&F plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge. |
| 92 | S&F socket 3 pin 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge . |
| 93 | S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 94 | S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge . |
| 95 | S & F Gang box surface type heavy duty suitable for 15 Amps switch and socket complete all as specified and directed by Engineer in charge. |
| 96 | Taking down old deteriorated louvers of exhaust fan and supply and fixing of new iron louvers of suitable size for exhaust fan of 300mm sweep including fixing materials such as nuts, bolts and washers etc complete all as specified and directed. |
| 97 | M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. |
| 98 | M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 99 | M & L in replacement for only single core PVC insulated cable 4 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge. |
| 100 | M&L in replacement copper cable flexible 2 core PVC insulated of size 23/.0076 ll each roll should not be less than 90 mtr as specified and directed by Engr-in-Charge. |
| 101 | S & F water heater storage type (Geyser) steel body vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure complete all as specified of capacity 25 ltr having heating element 2 KW and not less than 5 star rating with minimum two year warrant on product. Note : old unservicable geyser will be deposoted in MES yard. conversion against low rating to 5 star rating. |
| 102 | Supply,installation, testing and commissioning instant electric water heater with heating element of capacity 3 ltrs complete with all accessories such as safety valve, thermostat, NRV, connection piece etc and connecting with water mixture complete with all other accessories reqd for making water connections all as specified and directed. |
| 103 | Supply and fixing ceiling fans complete with blade, down rods, with remote and accessories rated speed not less than 330 RPM, 230 V, 1200 mm sweep, air delivery not less than 220 CMM, BEE five star rated voltage range 140 - 280 volts with brushess direct current motor (BLDC) all as specified and directed by Engr in Charge.(Against BLDC converson). Old fans shall be deposited to MES yard. |
| 104 | M & L in replacement for only single core PVC insulated cable 10 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge. |
| 105 | Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60cm long with brass nuts and rubber washers complete all as specified and directed. |
| 106 | Supply only thermostat for storage type water heater of 25 Ltrs capacity having max and min temperature range setting as per site requirement complete all as specified and directed. |
| 107 | Supply only heating element of 2 KW for any type with nut bolt washer complete all as directed. |
| 108 | Supply and fix in replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed. |
| 109 | Supply and fix in replacement of capacitor 2.5 Mfd, 240 V complete all as specified and directed. |
| 110 | Supply and fix in replacement of capacitor 1.5 Mfd, 240 V complete all as specified and directed. |
| 111 | S&F 35W High efficient LED street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. The color temperature is around 6500 K, IP:65 protected, power factornot less than 0.90, voltage variation range 180-270V, including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed. |
| 112 | S&F LED 2 X 2 ft backlite surface mounted fitting 36/40 Watts not less than 3600lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with colour temperature >5700k, IP 20, Power factor not less than 0.90, life time of 25000 burning hours , Ambient temperature 0 to 50 Deg C, including necessary fixing arrangements complete all as specified and directed. |
| 113 | M&L for breaking old existing wall and making a provn for fixing of 160 mm Electric Chimany pipe including making good to the disturbed wall/ portion and matching with existing colour.all as specified and directed. |
| 114 | Supply and Fixing wall mounted angular Electric chimney black colour of suction power not less than not less than 1200Cum/Hr,Al casette with stainless steel outer layer ,touch control panel,3 speed motor with 250 watt with decorative smart cooker hood SS and glass ,energy efficent Led light with digital display , including ducting not less than 12 feet as per site required complete all as specified and as directed by Engr-in-Charge. |
| 115 | Supply and fixing LED Bollard integral decorative with PMMA diffuser 10 watt of height 0.6 meter minimum with IP 65 protection suitable for single phase 230 volts 50 HZ AC Supply including LED bulb , Poles and PCC foundation of suitable ratio including cement work for finishing etc and nuts, bolts and washers etc for fixing of light fittings complete all as specified and directed by Engineer-in-Charge. |
| 116 | Supply and fixing new generation, post top energy saving environmently friendly 15W , long life aesthetically designed with symmetrical light distribuiton spun aluminium landscape luminaire with high power LED as light sources. |
| 117 | S&F in replacement 6 Sqmm twin core PVC insulated cable 1100 volts grade, single strand aluminium conductor cable drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories laid underground on earth for making electrical connections of bollard lights including necessary excavation and earth work not less than 30cms deep in any type of soil complete including returning filling and removal of excavted soil to a distance not less than 50 mtr all as specified and directed. |
| 118 | M & L for opening up the winding of ceiling fan 1200/1400 mm sweep any make any type and rewinding with super enamelled copper winding wire after inserting super enamelled insulating material binding it with insulating tape etc completely and varnishing well including drying completely. Replacement of worn out/unserviceable capacitor bearing , bush , safety pins, nuts, bolts, washers , rubber bush with ceiling fan clamp, cable PVC flexible 23/0076 and testing the ceiling fan after re-fixing of the blades to the entire satisfaction of Engineer-in-Charge. |
| 119 | Supply installation testing and commissioning of prepaid meter single phase, 2 wire 5-60A capacity,240 volts,50Hz, class-1.0 rating,IS 15884:2024, encased meter of protective class-II,load switching utilization category UC3 with key pad based token carrier interface including freedom device complete all as specified and directed. Model: Liberty 170 of make Secure. |
| 120 | Supply and fixing in replacement motor suitable for electric chimney not less than 250 watt single phase 230 volts 50 Hz of existing model including making necessary electrical connections all as specified and directed. |
| 121 | Supply and fixing in replacement PCB suitable for automatic electric chimney of existing model including making necessary electrical connections all as specified and directed. |
| 122 | Taking out old deteriorated casing caping of any description including taking out copper wire of any type alongwith it and supply and fixing new casing caping of 20mm including refixing the copper wire as dismantled earlier alongwith fixing materials such as casing clips and making good disturbed surfaces all as specified and directed by Engr-in-Charge at site complete. |
| 123 | Taking down of old/existing electric chimney of any make & model including exhaust pipe of any dia and length,strip opening of chimney after dismantling and unbolting all moveable/immoveable parts,cleaning of all complete chimney with suiatble cleaning agent upto entire satisfaction of Engineer-in-Charge, replacement of rusted nuts bolts& washers and defective parts as per existing make and model, reassembling all parts and refxing of chimney to its original position including exhaust pipe and testing on completion all as directed at site. Note: Parts shall be measured and paid separately. |
| 124 | Supply,installation,testing and commissioning of self priming regenerative pump 0.5/0.37 HP/KW, single Phase 220 volt+18%, discharge range 1950-450 LPH, head range 6-21 mtr insulation class ‘F’ of size 25x25mm complete with pressure switch as per manufacturer's design including mounting bracket of angle iron of suitable size with necessary nuts, bolts and washer etc and making electrical connection with suitable size copper multi stranded cable of suitable length and connecting with GI/ uPVC/cPVC water supply line of any dia/size alongwith accessories such as tee,bend, elbow and socket etc including making bypass arrangement for any fault in pump in future to provide uniterrupted water supply to building all as specified and directed at site by Engr-in-Charge. |
| 125 | Taking out old deteriorated casing caping of any description including taking out copper wire of any type alongwith it and supply and fixing new casing caping of 20mm including refixing the copper wire as dismantled earlier alongwith fixing materials such as casing clips and making good disturbed surfaces all as specified and directed by Engr-in-Charge at site complete. |
| 126 | Supply,installation, testing and commissioning instant electric water heater with heating element of capacity 3 ltrs complete with all accessories such as safety valve, thermostat, NRV, connection piece etc and connecting with water mixture complete with all other accessories reqd for making water connections all as specified and directed. |
| 127 | M&L in replacement fan motor of ventilating fan 250/300mm sweep plastic body operated on single phase 230 volts 50Hz electric supply as per sample complete including making necessary electrical connections and testing on site after replacement all as specified and directed by Engr-in-Charge at site. |
| 128 | M&L in replacement fan motor copper wound suitable for exhaust 300mm sweep operated on single phase 230 volts 50Hz electric supply as per sample complete including making necessary electrical connections and testing on site after replacement all as specified and directed by Engr-in-Charge at site. |
| 129 | Dismantling/disconnection of old unsv freedom device of any rating and supply installation testing and commissioning of freedom device with built in bluetooth features, real-time data consumption and token transfer compatible to prepaid meter single phase, 2 wire 5-60A capacity,240 volts,50Hz, class-1.0 rating,IS 15884:2024, with key pad based token carrier interface including connection with jack complete all as specified and directed. |
| 130 | Taking down old unsv wire of freedom device and supply and lay communication cable for in home display system suitable for establishing reliable and uninterrupted communication between Secure Liberty series prepaid meter/smart energy meter RJ-11 based twisted pair cable 6 core with copper conductor of size as recommended by manufacturer, shield twisted pair capable for supporting differential serial communication protocol for noise free data transmission and communication compatible to prepaid meter single phase, 5-60A capacity,240 volts,50Hz, class-1.0 rating,IS 15884:2024 complete all as specified and directed. |
| 131 | Taking down old deteriorated louvers of exhaust fan and supply and fixing of new iron louvers of suitable size for exhaust fan of 300mm sweep including fixing materials such as nuts, bolts and washers etc complete all as specified and directed. |
| 132 | Taking out old unsv chimney pipe of any dia and supply and fixing kitchen chimney exhaust pipe having diameter 6 inches minimum heat resistant aluminim of thickness 10mm minimum and length not less than 10 feet flexible ducting alongwith cowl universal fit for most chimney brand such as Hindware, Elica,Glen and Fber etc including MS clamp for supporting as required at site all as specified and directed by Engr-in-Charge. |
| 133 | M&L earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick, burried directly in to ground (earth pit) not less than 2.25 meters deep below GL with top edge of earth plate to less than 1.50 m below ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thikcness of 15 cm connected to GI earth strip 25x4 mm by means of nuts, bolts and washers to earth plate at one end and other end to contineous GI strip etc. including check nuts of GI and protction by the GI pipe light grade 40 mm nominal bore for earth strip from earth plate to 1500 mm above GL with FI clamps made out of 25x3mm fitted with nuts, bolts and washers and 2.5 m long watering pipe light grade of 20 mm nominal bore , 0.63 mm thick CI funnel, wiremesh, etc. complete including necessary earth work and excavation in soft/loose soil, PCC 1:2:4 type B1 earth pit and Precast RCC cover 65 mm thick duly reinforced with 6 mm dia. MS round bars @ 100 mm c/c both ways, earth phophrous bronze testing point , making good etc. all as specified and shown in electrical plate of SSR- Part-I. |
| 134 | Schedule of Credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender